Flat Slabs11

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 50

HELP.....

IIIIIIIIIIII II III IIII IIIIIIII..

1).Enter data only in the Shaded Cells

2).Use Tab key or Mouse to Move in to Cells

3).The Shaded Cells with an Input Instruction are marked with a Mark at Right Top Corne
of the cell as shown. To view the instruction Point the Cursor on the Cell

4).If Macros are not Enabled (Dropping Down List not working), Go to
Tools | Macro | Security, and set the Security Level to Medium. Close the File & Reope

5). The Analysis of Flat Slabs is done by Direct Design Method as specified in IS Codes

6).The Design and Detailing is as per IS Standards

IIIIIIII II IIII IIIIIIII..

No. Name of Spreadsheet Contents of the Spreadsheet

1 Help Instructions to Use this Workbook


2 Input Enter Dimensions of Flat Slab, Material Properties and
3 Dimen Fix the Dimensions of Capital and Drop if present
4 Anl Analysis of Flat Slabs by Direct Design Method
5 M_Dgm The Moment Diagram Showing the Locations of vario
Moments Calculated in the Analysis
6 Reinf Reinforcement Design at Various Locations in the Flat
7 Shear Check for the Shear Resistance of the Flat Slab
8 Detailing Drawings Showing Details of Reinforcements and its S

IIIIIII II III IIIIIII..

Name of the Company : ABCD


Site Reference : XYZ
Job No. : 5678
Design Done By : Ranjit
Design Checked By : MM
Design Approved By :

IIIIIII..

This workbook has been prepared by Mr. Ranjit P. Kangralkar under the guidence of
Prof. M. Manjunath. This workbook is the part of the Dissertation work for the partial
fulfilment of M. Tech. (Structural Engineering)
h an Input Instruction are marked with a Mark at Right Top Corner
To view the instruction Point the Cursor on the Cell

bled (Dropping Down List not working), Go to


y, and set the Security Level to Medium. Close the File & Reopen.

Slabs is done by Direct Design Method as specified in IS Codes

Contents of the Spreadsheet

Instructions to Use this Workbook


Enter Dimensions of Flat Slab, Material Properties and Loads
Fix the Dimensions of Capital and Drop if present
Analysis of Flat Slabs by Direct Design Method
The Moment Diagram Showing the Locations of various
Moments Calculated in the Analysis
Reinforcement Design at Various Locations in the Flat Slab
Check for the Shear Resistance of the Flat Slab
Drawings Showing Details of Reinforcements and its Shedule

ABCD
XYZ
5678
prepared by Mr. Ranjit P. Kangralkar under the guidence of
s workbook is the part of the Dissertation work for the partial
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

FLAT SLABS

b1

a1
a

IIIIIIIIII..

Total Longer Dimension of the floor in X Direction = a = 37.50 m

Total Smaller Dimension of the floor in Y Direction = b = 24.00 m

Centre to Centre in X direction = a1 = 7.50 m

Centre to Centre in Y direction = b1 = 6.00 m

Storey Height Below Flat Slab = H1 = 3.00 m

Storey Height Above Flat Slab = H2 = 3.00 m

IIIIIIIII..
Choose Concrete grade = M 20

Choose Steel Type = Fe 415415


IIIII..
Live Load = 1.50 kN/m²

Thickness of Floor Finish = 60 mm


ABCD

Ranjit
MM

X
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

IIIIIIIIII..

Interior Panels..
Shape of the Column = Circular

Diameter of Circular Column = 500 mm Min 470 mm

Column Capital = Present


Present
If Present Size of Column Capital Should be Between 1350 &mm1688 mm
Enter Diameter of Column Capital = 1500 mm
Size of Equivalent Square Column Capital = 1329 mm

Drop = Present
Present

Slab Thickness = 155 mm Min 154 mm

Drop Inclusive of Slab Thickness = 225 mm


Should be Between 194 &mm 233 mm

Drop along Long Span = 2000 mm Max 2060


Drop along Short Span = 2000 mm Max 2000

155
2000
1500

500
Section Through Panel along Long Span

155
2000
1500
500
Section Through Panel along Short Span
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

Exterior Panels..

Shape of the Column = Square


Square

Side of Square column = 500 mm

Column Capital = Present


Present
Size of Column Capital = 915 X 1330 mm

Drop = Present
Present

Drop Inclusive of Slab Thickness = 225 mm


Drop for Panel along Long Span = 1250 X 2000 mm
Drop for Panel along Short Span = 1250 X 2000 mm

155
1250 70
915
675

500
Section Through Panel along Long Span

155
1250 70
915
675

500
Section Through Panel along Short Span
ABCD

Ranjit
MM

mm O.K.

O.K.
O.K.

mm O.K.

O.K.

O.K.
O.K.

70

810

70

810
ABCD

Ranjit
MM
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

IIIIIIII II IIIIII IIIIII IIIIII..

Live Load = 1.50 kN/m²


Dead Load = 5.20 kN/m²
(Live + Dead) Factored Load = 10.04 kN/m²

Interior Frames…..
Frame Along LONG SPAN ( 7.50 (m

Clear Span = Ln = 6.17 m


Width of Panel = L = 6.00 m

Total Moment Along Long Span = Mo = 286.79 kN-m

Width of Column Strip = 3.00 m


Width of Middle Strip = 3.00 m

Interior Spans
Negative Moment = M(-ve) = 186.41 kN-m
Positive Moment = M(+ve) = 100.38 kN-m

Distribution of Moments M(-ve) and M(+ve) to Column Strip & Middle strip

- ve Moment in column strip = 139.81 kN-m


- ve Moment in middle strip = 46.60 kN-m

+ ve Moment in column strip = 60.23 kN-m


+ ve Moment in middle strip = 40.15 kN-m

Exterior Span
αc = 8.24
Exterior Negative Moment = Me(-ve) = 166.24 kN-m
Interior Negative Moment = Mi(-ve) = 189.52 kN-m
Positive Moment = M(+ve) = 109.07 kN-m

Distribution of Moments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip

Me(-ve) in column strip = 166.24 kN-m


Me(-ve) in middle strip = 0.00 kN-m

Mi(-ve) in column strip = 142.14 kN-m


Mi(-ve) in middle strip = 47.38 kN-m

M(+ve) in column strip = 65.44 kN-m


M(+ve) in middle strip = 43.63 kN-m

Frame Along SHORT SPAN ( 6.00 (m

Clear Span = Ln = 4.67 m


Width of Panel = L = 7.50 m

Total Moment Along Long Span = Mo = 205.39 kN-m

Width of Column Strip = 3.00 m


Width of Middle Strip = 4.50 m
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

Interior Spans
Negative Moment = M(-ve) = 133.50 kN-m
Positive Moment = M(+ve) = 71.88 kN-m

Distribution of Moments M(-ve) and M(+ve) to Column Strip & Middle strip

- ve Moment in column strip = 100.13 kN-m


- ve Moment in middle strip = 33.38 kN-m

+ ve Moment in column strip = 43.13 kN-m


+ ve Moment in middle strip = 28.75 kN-m

Exterior Span
αc = 5.27
Exterior Negative Moment = Me(-ve) = 112.22 kN-m
Interior Negative Moment = Mi(-ve) = 136.77 kN-m
Positive Moment = M(+ve) = 81.05 kN-m

Distribution of Moments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip

Me(-ve) in column strip = 112.22 kN-m


Me(-ve) in middle strip = 0.00 kN-m

Mi(-ve) in column strip = 102.58 kN-m


Mi(-ve) in middle strip = 34.19 kN-m

M(+ve) in column strip = 48.63 kN-m


M(+ve) in middle strip = 32.42 kN-m

Exterior Frames…..
Frame Along LONG SPAN ( 7.50 (m

Clear Span = Ln = 6.59 m


Width of Panel = L = 3.25 m

Total Moment Along Long Span = Mo = 176.91 kN-m

Width of Edge Column Strip = 1.75 m


Width of Edge Middle Strip = 1.50 m

Interior Spans
Negative Moment = M(-ve) = 114.99 kN-m
Positive Moment = M(+ve) = 61.92 kN-m

Distribution of Moments M(-ve) and M(+ve) to Column Strip & Middle strip

- ve Moment in column strip = 86.24 kN-m


- ve Moment in middle strip = 28.75 kN-m

+ ve Moment in column strip = 37.15 kN-m


+ ve Moment in middle strip = 24.77 kN-m
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

Exterior Span
αc = 8.24
Exterior Negative Moment = Me(-ve) = 102.54 kN-m
Interior Negative Moment = Mi(-ve) = 116.90 kN-m
Positive Moment = M(+ve) = 67.28 kN-m

Distribution of Moments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip

Me(-ve) in column strip = 102.54 kN-m


Me(-ve) in middle strip = 0.00 kN-m

Mi(-ve) in column strip = 87.68 kN-m


Mi(-ve) in middle strip = 29.23 kN-m

M(+ve) in column strip = 40.37 kN-m


M(+ve) in middle strip = 26.91 kN-m

Frame Along SHORT SPAN ( 6.00 (m

Clear Span = Ln = 5.09 m


Width of Panel = L = 4.00 m

Total Moment Along Long Span = Mo = 129.84 kN-m

Width of Column Strip = 1.75 m


Width of Middle Strip = 2.25 m

Interior Spans
Negative Moment = M(-ve) = 84.39 kN-m
Positive Moment = M(+ve) = 45.44 kN-m

Distribution of Moments M(-ve) and M(+ve) to Column Strip & Middle strip

- ve Moment in column strip = 63.29 kN-m


- ve Moment in middle strip = 21.10 kN-m

+ ve Moment in column strip = 27.27 kN-m


+ ve Moment in middle strip = 18.18 kN-m

Exterior Span
αc = 5.27
Exterior Negative Moment = Me(-ve) = 70.94 kN-m
Interior Negative Moment = Mi(-ve) = 86.46 kN-m
Positive Moment = M(+ve) = 51.24 kN-m

Distribution of Moments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip

Me(-ve) in column strip = 70.94 kN-m


Me(-ve) in middle strip = 0.00 kN-m

Mi(-ve) in column strip = 64.85 kN-m


Mi(-ve) in middle strip = 21.62 kN-m

M(+ve) in column strip = 30.74 kN-m


M(+ve) in middle strip = 20.50 kN-m
ABCD

Ranjit
MM

oments M(-ve) and M(+ve) to Column Strip & Middle strip

oments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip
ABCD

Ranjit
MM

oments M(-ve) and M(+ve) to Column Strip & Middle strip

oments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip
oments M(-ve) and M(+ve) to Column Strip & Middle strip
ABCD

Ranjit
MM

oments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip

oments M(-ve) and M(+ve) to Column Strip & Middle strip


oments Me(-ve) ,Mi(-ve) and M(+ve) to Column Strip & Middle strip
Company : ABCD

Site Ref.: XYZ Design By : Ranjit


Job No.: 5678 Checked By : MM
IIII IIIIIII IIIIIII IIIIIII IIIII IIII IIII..
Span
26.91 40.37 24.77 37.15 24.77 37.15 26.91 40.37
-102.54 -87.68 -86.24 -86.24 -86.24 -86.24 -87.68 -102.54 1.75
0.00 -29.23 -28.75 -28.75 -28.75 -28.75 -29.23 0.00 1.50
20.08 20.08
0.00 21.81 -23.69 -23.30 -23.30 -23.30 -23.30 -23.69 21.81 0.00 1.50
-166.24 -142.14 -139.81 -139.81 -139.81 -139.81 -142.14 -166.24
65.44 60.23 60.23 65.44 3.00

0.00 -47.38 -46.60 -46.60 -46.60 -47.38 0.00 3.00


43.63 40.15 40.15 43.63
-166.24 -142.14 -139.81 -139.81 -139.81 -139.81 -142.14 -166.24 3.00
65.44 60.23 60.23 65.44

0.00 -47.38 -46.60 -46.60 -46.60 -47.38 0.00 3.00


43.63 40.15 40.15 43.63
-166.24 -142.14 -139.81 -139.81 -139.81 -139.81 -142.14 -166.24 3.00
65.44 60.23 60.23 65.44
0.00 21.81 -23.69 -23.30 -23.30 -23.30 -23.69 21.81 0.00 1.50
20.08 20.08
0.00 -29.23 -28.75 -28.75 -28.75 -28.75 -29.23 0.00 1.50
-102.54 -87.68 -86.24 -86.24 -86.24 -86.24 -87.68 -102.54 1.75
26.91 40.37 24.77 37.15 24.77 37.15 26.91 40.37

C/C of Columns along Long Span = 7.50 m


Shape of the column is only indicative for its position, it may be circular/square
Company : ABCD

Site Ref.: XYZ Design By : Ranjit


Job No.: 5678 Checked By : MM
IIII IIIIIII IIIIIII IIIIIII IIIII IIIII IIII..
Span
0.00
-70.94 0.00 0.00 -112.22 0.00 -112.22 0.00 -112.22 0.00 -70.94
16.21
30.74 20.50 48.63 32.42 48.63 32.42 48.63 16.21 20.50 30.74
-17.10
-64.85 -21.62 -17.10 -102.58 -34.19 -102.58 -34.19 -102.58 -21.62 -64.85
-63.29 -21.10 -16.69 -100.13 -33.38 -100.13 -33.38 -100.13 -21.10 -63.29
-16.69
27.27 18.18 43.13 28.75 43.13 28.75 43.13 14.38 18.18 27.27
14.38 -16.69
-63.29 -21.10 -16.69 -100.13 -33.38 -100.13 -33.38 -100.13 -21.10 -63.29
-63.29 -21.10 -16.69 -100.13 -33.38 -100.13 -33.38 -100.13 -21.10 -63.29
14.38 -16.69
27.27 18.18 43.13 28.75 43.13 28.75 43.13 14.38 18.18 27.27
-16.69
-63.29 -21.10 -16.69 -100.13 -33.38 -100.13 -33.38 -100.13 -21.10 -63.29
-64.85 -21.62 -17.10 -102.58 -34.19 -102.58 -34.19 -102.58 -21.62 -64.85
-17.10
30.74 20.50 48.63 32.42 48.63 32.42 48.63 16.21 20.50 30.74
16.21
-70.94 0.00 0.00 -112.22 0.00 -112.22 0.00 -112.22 0.00 -70.94
0.00
2.25 2.25 4.50 4.50 2.25 2.25
1.75 3.00 3.00 3.00 1.75
C/C of Columns along Short Span = 6.00 m

Shape of the column is only indicative for its position, it may be circular/square
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

IIIIII III IIIIIIII


For Column Strip = 12 mm

For Middle Strip = 8 8 mm

IIIIIIIII IIIII (I) II IIIIIII IIIIIIII


Along Long span Along Short span
For Column Strip For Column Strip
At Intermediate Support = 199mm At Intermediate Support =
At Exterior Support = 199mm At Exterior Support =
At Midspan = 129mm At Midspan =
For Middle Strip For Middle Strip
At Support and Midspan = 129mm At Support and Midspan =

IIIIIIIIIIIII IIIIII.. fck =


Interior Frames….. fy =
Along Long span Ru =
Column Strip = 3.00 m
Ultimate Moment at Intermediate Supports = 142.14 kN-m
Required Effective Depth = 131.04 mm
Required Ast for the Strip = 2138.20 mm²

* Provide 12 mm Dia Bars at155 mm C/C

Ultimate Moment at Exterior Supports = 166.24 kN-m


Required Effective Depth = 141.71 mm
Required Ast for the Strip = 2538.90 mm²

* Provide 12 mm Dia Bars at130 mm C/C

Ultimate Moment at Midspan = 65.44 kN-m


Required Effective Depth = 88.91 mm
Required Ast for the Strip = 1531.53 mm²

* Provide 12 mm Dia Bars at220 mm C/C

Middle Strip = 3.00 m


Ultimate Moment at Intermediate Edges = 47.38 kN-m
Required Effective Depth = 75.66 mm
Required Ast for the Strip = 1080.36 mm²

mm Dia Bars at mm C/C


* Provide 8 mm Dia Bars at135 mm C/C

Ultimate Moment at Exterior Edges = 0.00 kN-m


Required Effective Depth = 0.00 mm
Required Ast for the Strip = 697.50 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Ultimate Moment at Midspan = 43.63 kN-m


Required Effective Depth = 88.91 mm
Required Ast for the Strip = 989.69 mm²

* Provide 8 mm Dia Bars at150 mm C/C


Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

Along Short span


Column Strip = 3.00 m
Ultimate Moment at Intermediate Supports = 102.58 kN-m
Required Effective Depth = 111.32 mm
Required Ast for the Strip = 1597.41 mm²

* Provide 12 mm Dia Bars at210 mm C/C

Ultimate Moment at Exterior Supports = 112.22 kN-m


Required Effective Depth = 116.43 mm
Required Ast for the Strip = 1758.48 mm²

* Provide 12 mm Dia Bars at190 mm C/C

Ultimate Moment at Midspan = 48.63 kN-m


Required Effective Depth = 76.65 mm
Required Ast for the Strip = 1218.80 mm²

* Provide 12 mm Dia Bars at275 mm C/C

Middle Strip = 4.50 m


Ultimate Moment at Intermediate Edges = 34.19 kN-m
Required Effective Depth = 52.48 mm
Required Ast for the Strip = 1046.25 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Ultimate Moment at Exterior Edges = 0.00 kN-m


Required Effective Depth = 0.00 mm
Required Ast for the Strip = 1046.25 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Ultimate Moment at Midspan = 32.42 kN-m


Required Effective Depth = 51.10 mm
Required Ast for the Strip = 1046.25 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Exterior Frames…..
Along Long span
m
Half Column Strip = 1.75 m
Ultimate Moment at Intermediate Supports = 87.68 kN-m
Required Effective Depth = 134.75 mm
Required Ast for the Strip = 1325.64 mm²

* Provide 12 mm Dia Bars at145 mm C/C

Ultimate Moment at Exterior Supports = 102.54 kN-m


Required Effective Depth = 145.73 mm
Required Ast for the Strip = 1575.89 mm²

* Provide 12 mm Dia Bars at125 mm C/C


Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

Ultimate Moment at Midspan = 40.37 kN-m


Required Effective Depth = 91.43 mm
Required Ast for the Strip = 950.12 mm²

* Provide 12 mm Dia Bars at205 mm C/C

Half Middle Strip = 1.50 m


Ultimate Moment at Intermediate Edges = 29.23 kN-m
Required Effective Depth = 84.03 mm
Required Ast for the Strip = 676.96 mm²

* Provide 8 mm Dia Bars at110 mm C/C

Ultimate Moment at Exterior Edges = 0.00 kN-m


Required Effective Depth = 0.00 mm
Required Ast for the Strip = 348.75 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Ultimate Moment at Midspan = 26.91 kN-m


Required Effective Depth = 80.64 mm
Required Ast for the Strip = 619.22 mm²

* Provide 8 mm Dia Bars at120 mm C/C

Along Short span


Half Column Strip = 1.75 m
Ultimate Moment at Intermediate Supports = 64.85 kN-m
Required Effective Depth = 115.89 mm
Required Ast for the Strip = 1015.47 mm²

* Provide 12 mm Dia Bars at190 mm C/C

Ultimate Moment at Exterior Supports = 70.94 kN-m


Required Effective Depth = 121.21 mm
Required Ast for the Strip = 1118.60 mm²

* Provide 12 mm Dia Bars at175 mm C/C

Ultimate Moment at Midspan = 30.74 kN-m


Required Effective Depth = 121.21 mm
Required Ast for the Strip = 775.87 mm²

* Provide 12 mm Dia Bars at255 mm C/C

Half Middle Strip = 2.25 m


Ultimate Moment at Intermediate Supports = 21.62 kN-m
Required Effective Depth = 59.01 mm
Required Ast for the Strip = 524.69 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Ultimate Moment at Exterior Supports = 0.00 kN-m


Required Effective Depth = 0.00 mm
Required Ast for the Strip = 523.13 mm²

* Provide 8 mm Dia Bars at215 mm C/C


Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

Ultimate Moment at Midspan = 20.50 kN-m


Required Effective Depth = 57.46 mm
Required Ast for the Strip = 523.13 mm²

* Provide 8 mm Dia Bars at215 mm C/C

Half Column Strip


Half Middle Strip
Column Strip
Middle Strip

Interior Frame
Interior Frame

Exterior Frame
ABCD

Ranjit
MM

189mm
189mm
119mm

119mm

20 N/mm²
415 N/mm²
2.76 N/mm²
ABCD

Ranjit
MM
ABCD

Ranjit
MM
ABCD

Ranjit
MM

Span
Company : ABCD

Site Ref.: XYZ Design By :


Job No.: 5678 Checked By :

IIIII III IIIII..


Internal Column…..
Average Effective Depth at the Section
Average Effective Depth of Drop = 194 mm
Average Effective Depth of Slab = 124 mm
Location of Critical Perimeter = 97 mm From Column Capital
Smaller Projection of Drop = 250 mm From Column Capital

* Critical Perimeter is Within Drop


Diameter of Critical Perimeter = 1694 mm
Weight of Drop Below Slab = 1.75 kN/m²
Design Shear at Critical Section = VUD = 432.33 kN
Design Shear of Concrete = τu = 1.12 N/mm²
Shear Resistance of Concrete = 1154.30 kN SAFE

Exterior Column…..
Average Effective Depth at the Section
Average Effective Depth of Drop = 194 mm
Average Effective Depth of Slab = 124 mm

Maximum Unbalanced Moment = 166.24 kN-m


Larger Side of Column Capital = C1 = 915 mm
Smaller Side of Column Capital = C2 = 1330 mm
A1 = 1012 mm
A2 = 1524 mm
α= 0.648
* Critical Perimeter is Within Drop

Perimeter along the Critical Section = Po = 3548 mm


Design shear at critical Section = VUD = 225.53 kN
Area at Critical section = 688312 mm²
Distance Between Axis of the Column and
the Centroidal Axis of the Critical Section = 265.85 mm

τc = 7.79E+10 mm4

τmax = 0.139 N/mm²


βo = 0.66
Design Shear Strength = τc = 1.12 N/mm² SAFE
ABCD

Ranjit
MM

From Column Capital


From Column Capital
Company : ABCD

Site Ref.: XYZ Design By : Ranjit


Job No.: 5678 Checked By : MM

IIII IIIIIII IIIIIIIIIIIII IIIII IIII IIII.. Span at Top CS : Column Strip
at Bottom MS : Middle Strip
MS
a c b d b d b c a
CS 1.75 Dia Lengths (mm(
e f f f e Mark
g 1.50 (mm( L1 L2
MS g h h
i i a 12 2310 1400
MS j j j
k l 1.50 b 12 5120 3300
l k
m n n n m c 12 7325 6700
CS d 12 7350 6100
o p p o 3.00
e 8 1540
i j j j i
3.00 f 8 3580
MS
k l l k g 8 7325 6275
m n n n m h 8 7350 5250
3.00
CS
p p o i 8 1540
o
j 8 3580
i j j j i k 8 7325 6275
MS 3.00
k l l k l 8 7350 5250
m n n n m m 12 2310 1400
3.00
CS
p p o n 12 5120 3300
o
i j j j i 1.50 o 12 7325 6700
MS k l l k
p 12 7350 6100
MS e g f h f h f g e
1.50
CS c d d c 1.75
a b b b a
NOTES:
1). For bars marked as a, e, i & m (at exterior supports), the lengths given are from face of supports, anchorage should be added to it.
2). Wherever two different lengths (L1 & L2) are given for a particular mark, these lengths should be used alternately starting from the larger length.
Company : ABCD

Site Ref.: XYZ Design By : Ranjit


Job No.: 5678 Checked By : MM

IIII IIIIIII IIIIIIIIIIIII IIIII IIIII IIII.. Span at Top CS : Column Strip
at Bottom MS : Middle Strip
CS MS CS MS CS MS MS CS MS
CS MS MS

E Dia Lengths (mm(


A I M I M I M I E A Mark
(mm( L3 L4
C G K G C A 12 1815 1100
O K O K O K
B 12 4130 2700
B F J N J N N J F B C 12 5825 5200
J
D 12 5850 4600
E 8 1210
D H L P L P L P L H D 8 2920
F
G 8 5825 5000
B F J N J N F B H 8 5850 4200
N J J
I 8 1210
J 8 2920
D H L P L P L P L H D K 8 5825 5000
L 8 5850 4200
B F J N N F B M 12 1815 1100
J N J J
N 12 4130 2700
O 12 5825 5200
C G K O K O K O K G C 12 5850 4600
P

A E I M I M I M I E A
I

2.25 4.50 4.50 2.25 2.25


1.75 2.25 3.00 3.00 3.00 1.75
NOTES:
1). For bars marked as A, E, I & M (at exterior supports), the lengths given are from face of supports, anchorage should be added to it.
2). Wherever two different lengths (L3 & L4) are given for a particular mark, these lengths should be used alternately starting from the larger length.
Ranjit
MM

CS : Column Strip
MS : Middle Strip
MS

Spacing
(mm(
125
145
205
205
215
110
120
120
215
135
150
150
130
155
220
220
icular mark, these lengths should be used alternately starting from the larger length.
CS : Column Strip
MS : Middle Strip
MS

Spacing
(mm(
175
190
255
255
215
215
215
215
215
215
215
215
190
210
275
275
icular mark, these lengths should be used alternately starting from the larger length.