Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

14 DMR 9300 BaseStations

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

DMR • BASE STATION INFRASTRUCTURE

TB9300 DMR Base Stations _

 Base Stations
 Options & Accessories

© Tait Limited June 2014 Page 1 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300
Intelligent • Flexible • High Performance
Building on the industry-wide success of the Tait TB8100 Base
Stations, the new generation TB9300 DMR base station sets the
standard for high-performing radio communications technology. This
software-flexible product is built on a foundation of flexibility for
system integration, modularity and robustness.

All TB9300 systems offer continuous duty cycle operation at full


performance specifications within the complete temperature and
altitude range.

With flexible, modular design and practical features, the TB9300


raises the bar for DMR base stations/repeaters.

Its practical features coupled with impressive RF performance to


really make a difference in high interference/RF sites makes the
TB9300 the next generation base station.

The TB9300 offers you the following features:


Frequency 50W 100W 50W DUAL
 Full IP connectivity allows efficient scaling and design of your
network
148–174MHz   
 Full remote control, diagnostics & self-monitoring capability
400-440MHz   
 Compact 4U rack profile
440-480MHz   
 Choice of single 100W or single 50W or dual 50W
configurations per subrack 470-520MHz  
 Programmable power input in 1W steps, per channel 762-870MHz   
 Seamless backup battery operation and charging with ACDC
= 12/24/48V PMU solution
supply

Note:
All TB9300 packages include:  DC power options are 12/24/48VDC with AUX output.
 Complete subrack including front panel with triple fans  AC power options are 110/240VAC + AUX output.
 Control panel, modules & software features as described  ACDC power options are AC + 12/24/48VDC + AUX output.
 Power cord for AC & ACDC systems  Auxiliary (AUX) power output voltage options are 12VDC, 24VDC
 Installation guide or 48VDC AUX.

Note:

 Not all products have compliance in all regions/countries. Please


check the Tait Product Specification sheet or contact your Tait
Representative for further information.

© Tait Limited June 2014 Page 2 of 18 www.taitradio.com


© Tait Limited 2013. www.taitradio.com
DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300
Base Station – VHF Single 50W & 100W
Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to pages12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply.

ITEM CODE DESCRIPTION


TB9315-B3H0-0000-YZAA-10 Base Station Repeater 148-174M 50W AC
TB9315-B3H0-0000-Y0AA-10 Base Station Repeater 148-174M 50W DC
TB9315-B3H0-0000-YZAA-10 Base Station Repeater 148-174M 50W ACDC
TB9335-B3M0-0000-YZAA-10 Base Station Repeater 148-174M 100W AC
TB9335-B3M0-0000-Y0AA-10 Base Station Repeater 148-174M 100W DC
TB9335-B3M0-0000-YZAA-10 Base Station Repeater 148-174M 100W ACDC

© Tait Limited June 2014 Page 4 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300

Base Station – UHF Single 50W


Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to pages12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply

ITEM CODE DESCRIPTION


TB9315-H1H0-0000-YZAA-10 Base Station Repeater 400-440M 50W AC
TB9315-H1H0-0000-Y0AA-10 Base Station Repeater 400-440M 50W DC
TB9315-H1H0-0000-YZAA-10 Base Station Repeater 400-440M 50W ACDC
TB9315-H2H0-0000-YZAA-10 Base Station Repeater 440-480M 50W AC
TB9315-H2H0-0000-Y0AA-10 Base Station Repeater 440-480M 50W DC
TB9315-H2H0-0000-YZAA-10 Base Station Repeater 440-480M 50W ACDC
TB9315-H3H0-0000-YZAA-10 Base Station Repeater 470-520M 50W AC
TB9315-H3H0-0000-Y0AA-10 Base Station Repeater 470-520M 50W DC
TB9315-H3H0-0000-YZAA-10 Base Station Repeater 470-520M 50W ACDC

© Tait Limited June 2014 Page 5 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300
Base Station – UHF Single 100W
Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to pages12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply

ITEM CODE DESCRIPTION


TB9335-H1M0-0000-YZAA-10 Base Station Repeater 400-440M 100W AC
TB9335-H1M0-0000-Y0AA-10 Base Station Repeater 400-440M 100W DC
TB9335-H1M0-0000-YZAA-10 Base Station Repeater 400-440M 100W ACDC
TB9335-H2M0-0000-YZAA-10 Base Station Repeater 440-480M 100W AC
TB9335-H2M0-0000-Y0AA-10 Base Station Repeater 440-480M 100W DC
TB9335-H2M0-0000-YZAA-10 Base Station Repeater 440-480M 100W ACDC

© Tait Limited June 2014 Page 6 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300

Base Station – 700/800MHz Single


Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to pages 12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply.

ITEM CODE DESCRIPTION


TB9315-K4H0-0000-YZAA-10 Base Station Repeater 762-870M 50W AC
TB9315-K4H0-0000-Y0AA-10 Base Station Repeater 762-870M 50W DC
TB9315-K4H0-0000-YZAA-10 Base Station Repeater 762-870M 50W ACDC
TB9335-K4M0-0000-YZAA-10 Base Station Repeater 762-870M 100W AC
TB9335-K4M0-0000-Y0AA-10 Base Station Repeater 762-870M 100W DC
TB9335-K4M0-0000-YZAA-10 Base Station Repeater 762-870M 100W ACDC

© Tait Limited June 2014 Page 7 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300
Base Station – VHF Dual
Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to pages 12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply.

ITEM CODE DESCRIPTION


TB9315-B3H0-B3H0-YZAA-10 Base Station Repeater 148-174M 50/50W AC
TB9315-B3H0-B3H0-Y0AA-10 Base Station Repeater 148-174M 50/50W DC
TB9315-B3H0-B3H0-YZAA-10 Base Station Repeater 148-174M 50/50W ACDC

© Tait Limited June 2014 Page 8 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300
Base Station – UHF Dual
Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to pages 12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply.

ITEM CODE DESCRIPTION


TB9315-H1H0-H1H0-YZAA-10 Base Station Repeater 400-440M 50/50W AC
TB9315-H1H0-H1H0-Y0AA-10 Base Station Repeater 400-440M 50/50W DC
TB9315-H1H0-H1H0-YZAA-10 Base Station Repeater 400-440M 50/50W ACDC
TB9315-H2H0-H2H0-YZAA-10 Base Station Repeater 440-480M 50/50W AC
TB9315-H2H0-H2H0-Y0AA-10 Base Station Repeater 440-480M 50/50W DC
TB9315-H2H0-H2H0-YZAA-10 Base Station Repeater 440-480M 50/50W ACDC
TB9315-H3H0-H3H0-YZAA-10 Base Station Repeater 470-520M 50/50W AC
TB9315-H3H0-H3H0-Y0AA-10 Base Station Repeater 470-520M 50/50W DC
TB9315-H3H0-H3H0-YZAA-10 Base Station Repeater 470-520M 50/50W ACDC

© Tait Limited June 2014 Page 9 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


TB9300
Base Station – 700/800MHz Dual
Standard Package Includes:

 Subrack including front panel with triple fans

 Control panel

 Power Management Unit (PMU) options as selected

 Power Amplifier (PA)

 Reciter (receiver/exciter) with system interface

 Installation guide

Options:

 PMU options are:


 AC = Input of 240VAC with 12VDC AUX output
 DC = Input of 12VDC with 12VDC AUX output
 ACDC = Inputs of 240VAC + 12VDC with 12VDC AUX output
 Auxiliary (AUX) power output voltage options are 12VDC, 24VDC or 48VDC AUX.
 Other PMU options are also available, please refer to page 12 to 14
 Choose the PMU (“Y” value) from the TB9300 Base Station configuration table on page 3
 Power Cord: Choose the Power Cord (“Z” value) from the TB9300 Base Station configuration table on page 3. Please note that for the DC
PMU option, a power cord is not required.

Note:

 Not all products have compliance in all regions/countries. Please check the Tait Product Specification sheet or contact your Tait
Representative for further information.

 FULL DMR - Software Feature License TBAS300 is included in the Base Station configuration (i.e. one SFE per reciter). This one license
will activate two voice channels on a single Reciter. (e.g. TB9315-B3H0-0000-YZAA-10) At least one Trunking SFE license is required per
Reciter for DMR Trunking operation.

 DMR EXPRESS - Software Feature License TBAS302 used with TNAS320 (e.g. TB9315-B3H0-0000-YZAC-10)

 DMR ACCESS - Software Feature License TBAS303 is included in the DMR Access Stand Alone Base Station configuration without a
node controller. (e.g. TB9315-B3H0-0000-YZAD-10).

 For more configuration options, please refer to the TB9300 Base Station configuration table on page 3. Additional configuration costs may
apply.

ITEM CODE DESCRIPTION


TB9315-K4H0-K4H0-YZAA-10 Base Station Repeater 762-870M 50/50W AC
TB9315-K4H0-K4H0-Y0AA-10 Base Station Repeater 762-870M 50/50W DC
TB9315-K4H0-K4H0-YZAA-10 Base Station Repeater 762-870M 50/50W ACDC

© Tait Limited June 2014 Page 10 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300
Reciter (Receiver/Exciter)
Overview:

 A Reciter consists of a receiver and exciter, including RF, DSP & audio stages to give
stable performance for the life of the product.

ITEM CODE DESCRIPTION


T01-01105-DAAA TB9300 Reciter 148-174M
T01-01105-KAAA TB9300 Reciter 400-440M
T01-01105-LAAA TB9300 Reciter 440-480M
T01-01105-MAAA TB9300 Reciter 470-520M
T01-01105-NAAA TB9300 Reciter 762-870M

© Tait Limited June 2014 Page 11 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300
Power Amplifiers (PA)
Used with the PMU TB9300 system:

 Broadband

 Remotely configurable and programmable

 100% duty cycle @ 60°C (140°F)

 2.5 millisecond key-up-time

 Programmable output power in 1W steps

 Up to two 50W PA can be fitted into a TB9300 subrack

 A limit of one 100W PA can be fitted into a TB9300 subrack

50W PA 100W PA
ITEM CODE DESCRIPTION
T01-01136-CAAA TB9300 Power Amplifier 136-174M 50W Constant Envelope
T01-01136-CBAA TB9300 Power Amplifier 136-174M 100W Constant Envelope
T01-01136-JAAA TB9300 Power Amplifier 380-520M 50W Constant Envelope
T01-01136-JBAA TB9300 Power Amplifier 380-520M 100W Constant Envelope
T01-01136-NAAA TB9300 Power Amplifier 762-870M 50W Constant Envelope
T01-01136-NBAA TB9300 Power Amplifier 762-870M 100W Constant Envelope

© Tait Limited June 2014 Page 12 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300
Power Management Units (PMU)
Standard Features for Standby power supply include:

 Seamless ACDC change over

 DC options are 12, 24, 48VDC

 Enable AC, DC or ACDC supply

Standard Features for Auxiliary power supply include:

 TB9300 base station does not use the output of the Auxiliary power supply

 Floating output may be negatively or positively earthed

 Can be configured to be on all of the time (to supply external equipment) or only
while mains is available

Note:

 Standby and Auxiliary Power Supplies are included as standard

AC – Power Management Units (PMU)


Standard Package Includes:

 88 to 264V input with power factor correction

 Sufficient output power to drive 1 x 100W transmitter or up to two 50W transmitters

 Remotely controllable and programmable

 Built-in alarms and diagnostics

ITEM CODE DESCRIPTION


TBA30A0-0100 TB8000/9000 Power Management Unit AC aux12
TBA30A0-0200 TB8000/9000 Power Management Unit AC aux24
TBA30A0-0400 TB8000/9000 Power Management Unit AC aux48

© Tait Limited June 2014 Page 13 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300
DC – Power Management Units (PMU)
Standard Package Includes:

 Operates from 12, 24 or 48VDC supply

 Input supply can be negatively or positively earthed

 Sufficient output power to drive 1 x 100W transmitter or up to two 50W transmitters

 Remotely controllable and programmable

 Built-in alarms and diagnostics

ITEM CODE DESCRIPTION


TBA3001-1100 TB8000/9000 Power Management Unit DC12 aux12
TBA3001-1200 TB8000/9000 Power Management Unit DC12 aux24
TBA3001-1400 TB8000/9000 Power Management Unit DC12 aux48
TBA3002-2100 TB8000/9000 Power Management Unit DC24 aux12
TBA3002-2200 TB8000/9000 Power Management Unit DC24 aux24
TBA3002-2400 TB8000/9000 Power Management Unit DC24 aux48
TBA3004-4100 TB8000/9000 Power Management Unit DC48 aux12
TBA3004-4200 TB8000/9000 Power Management Unit DC48 aux24
TBA3004-4400 TB8000/9000 Power Management Unit DC48 aux48

© Tait Limited June 2014 Page 14 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300
ACDC - Power Management Units (PMU)
Standard Package Includes:

 Seamless and automatic switching from AC to DC

 AC operates 88 to 264V input with power factor correction

 DC operates from 12, 24 or 48VDC supply

 DC input supply can be negatively or positively earthed

 Sufficient output power to drive 1 x 100W transmitter or up to two 50W transmitters

 Remotely controllable and programmable

 Built-in alarms and diagnostics

ITEM CODE DESCRIPTION


TBA30A1-1100 TB8000/9000 Power Management Unit ACDC12 aux12
TBA30A1-1200 TB8000/9000 Power Management Unit ACDC12 aux24
TBA30A1-1400 TB8000/9000 Power Management Unit ACDC12 aux48
TBA30A2-2100 TB8000/9000 Power Management Unit ACDC24 aux12
TBA30A2-2200 TB8000/9000 Power Management Unit ACDC24 aux24
TBA30A2-2400 TB8000/9000 Power Management Unit ACDC24 aux48
TBA30A4-4100 TB8000/9000 Power Management Unit ACDC48 aux12
TBA30A4-4200 TB8000/9000 Power Management Unit ACDC48 aux24
TBA30A4-4400 TB8000/9000 Power Management Unit ACDC48 aux48

© Tait Limited June 2014 Page 15 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300

Software Licenses
ITEM CODE DESCRIPTION
TBAS300 SFE Key - DMR Trunking SFE License with TDMA operation (93)
TBAS302 SFE Key - DMR Express SFE License with TDMA operation (93)
TBAS303 SFE Key - DMR Access SFE License with TDMA operation (93)

Software maintenance and support is available on an annual renewal basis. Software maintenance ensures your software investment
remains fully operational, high performing and current through updates that also include valuable new features – please contact your
Tait Representative for further details

© Tait Limited June 2014 Page 16 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300

© Tait Limited June 2014 Page 17 of 18 www.taitradio.com


DMR • BASE STATION INFRASTRUCTURE
_

DIGITAL BASE STATIONS


SPARES OPTIONS & ACCESSORIES TB9300
Accessories
ITEM CODE DESCRIPTION
Power Management Unit (PMU) Option Boards
TBA-SP-WDA1 TB81/91/93 Spare PMU Auxiliary Supply 12VDC 40W
TBA-SP-WDA2 TB81/91/93 Spare PMU Auxiliary Supply 24VDC 40W
TBA-SP-WDA4 TB81/91/93 Spare PMU Auxiliary Supply 48VDC 40W
Support Bracket
TBAA03-13 TB8000/9000 Auxiliary Support Bracket
Handle
TBAA03-16 TB8000/9000 Carrying Handles
Power Chords
T952-310 Mains Power Lead ANZ-IEC
T952-320 Mains Power Lead UK-IEC
T952-330 Mains Power Lead EUR-IEC
T952-340 Mains Power Lead US/CAN IEC
T952-310 Mains Power Lead ANZ-IEC

© Tait Limited June 2014 Page 18 of 18 www.taitradio.com