Heat Pumps Up To 2000 KW
Heat Pumps Up To 2000 KW
Heat Pumps Up To 2000 KW
Heating systems
Industrial systems
Refrigeration systems
2/3
In industrialised Western nations, heat generation for residential and commercial buildings
accounts for the largest proportion of energy consumption – and therefore offers the
greatest savings potential. Advanced and energy efficient heating systems from Viessmann
are in use around the world, not only in many private households, but also in numerous
major international projects, where they make an important contribution to the sustainable
conservation of energy reserves.
Time and again, Viessmann successfully overcomes the most diverse challenges facing
manufacturers of advanced heating technology by offering innovative solutions – in historical
listed buildings, highly productive industrial complexes and the large scale residential and
commercial arena.
Viessmann has been developing and manufacturing heat pumps for international markets
for more than 35 years. Its product range includes customer-specific solutions and matching
services.
Contents
4/5
Introduction
from page 6
Heating with renewable energy from the environment –
even in the higher output ranges
Heat pumps offer ideal conditions for reducing Recovering environmental energy
heating bills and achieving environmentally Various natural sources are suited to heat
responsible heat generation. After all, the recovery using a heat pump:
energy a heat pump uses is free and available
in unlimited supply from the environment. Water – such as groundwater, river or lake
water, waste water
With a heat pump, up to 80 percent of the Ground – via geothermal probes,
total energy demand can be drawn from nature geothermal collectors, energy piles
in a highly effective and environmentally Air
responsible manner. Only 20 to 30 percent Waste heat
electrical energy needs to be invested.
Not all of these heat sources can be used
The principle is as simple as it is ingenious: in all locations. It is therefore necessary to
the solar energy stored in the ambient air, consult the relevant authorities before making
ground and groundwater is used to efficiently a decision, and discuss the technical options
heat domestic hot water and heating water. with Viessmann.
The Vitocal 300-G/-W Pro heat pumps up Proven and reliable technology
to 290 kW are in series production. The Pro The control philosophy was adopted from the
series features all the characteristics of the Vitocal series for detached and two-family
highly efficient Vitocal 300-G series. The seven houses. Here too, the Refrigerant Cycle
output sizes enable most requirements from Diagnostic system (RCD) checks efficiency
residential and commercial buildings to be continuously and safeguards reliable function
reliably met. These appliances are standardised, at any operating point through the interaction Easy to operate Vitotronic control
unit with plain text and graphic
enabling quick and comprehensive system between the electronic expansion valve (EEV)
display
engineering, as well as transparent cost and extensive sensor technology.
calculation parameters. Higher output levels
can be achieved by linking up to five Vitocal The Vitotronic 200 regulates up to three
300 Pro heat pumps in a single cascade. heating circuits and, thanks to its natural
cooling function, ensures a pleasant ambience
Space efficient design on hot summer days. With the optional
The hermetically sealed design with new Vitocom 300 communication module, a
scroll technology requires little space. At only comprehensive range of system optimisation
855 mm wide, with removable casing panels settings can be made from anywhere via
and a clearance at the bottom to enable it to internet or mobile phone.
be moved by pallet truck, the appliance is very
easy to handle. Series with PLC-based Vitotronic
All models are further available with a
Direct use of groundwater without an programmable logic controller (PLC). Data
intermediate circuit communication via Modbus/BACnet or LAN
Only the Vitocal 300-W Pro series, with its in particular provides options for even more
stainless steel tubular evaporator, provides targeted integration into BMS systems.
a reliable solution for the direct use of The PLC-based Vitotronic also allows
groundwater without an additional intermediate management of dry coolers and control of
circuit, thus minimising installation costs. up to three heating/cooling circuits.
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 86.6 111 82.8 106.6
Cooling capacity kW 68.9 88.7 65.8 84.6
Power consumption kW 18.7 23.5 17.9 23.2
Coefficient of performance ¡ in htg mode 4.6 4.7 4.6 4.6
Dimensions
Length mm 1343 1343 1343 1343
Width mm 911 911 911 911
Height mm 1650 1650 1650 1650
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 134.6 173.2 222.0
Cooling capacity kW 106.6 137.6 177.4
Power consumption kW 29.3 37.3 47.0
Coefficient of performance ¡ in htg mode 4.6 4.6 4.7
Dimensions
Length mm 1932 1932 1932
Width mm 911 911 911
Height mm 1650 1650 1650
Performance data
(to EN 14511, W10/W35 °C, 5 K spread)
Rated heating output kW 116 140.1 112.1 145.1
Cooling capacity kW 102 120 94.2 121.6
Power consumption kW 20.2 24.2 18.6 24.4
Coefficient of performance ¡ in htg mode 5.74 5.79 6.0 5.94
Dimensions
Length mm 1932 1932 1932 1932
Width mm 911 911 911 911
Height mm 1650 1650 1650 1650
Performance data
(to EN 14511, W10/W35 °C, 5 K spread)
Rated heating output kW 186 240 290
Cooling capacity kW 157 199 244
Power consumption kW 32.1 42.1 49.5
Coefficient of performance ¡ in htg mode 5.9 5.7 5.8
Dimensions
Length mm 2521 2521 2521
Width mm 911 911 911
Height mm 1650 1650 1650
The frame design of the brine/water heat Remote monitoring and communication
pump makes the powerful and efficient The control unit recognises numerous data
Vitocal 350-G Pro heat pump easier to handle communication options. From a simple
and install. The sound insulated casing analogue modem to a LAN-based system:
(supplied separately) offers a snug fit and Modbus technology and BACnet can be
reduces the transport weight by around used to enable the system to be accessed
200 kg. The unit is ideal for modernising via the internet for remote maintenance and
heating systems with high flow temperatures. communication purposes. Large colour touchscreen with clear
display
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 27.2 34.3 56.1 76 96.9
Cooling capacity kW 20.8 26.4 43.2 58.8 74.6
Power consumption kW 6.4 7.9 12.8 17.3 21.9
Coefficient of performance ¡in heating mode 4.2 4.4 4.4 4.4 4.4
Performance data*
(to EN 14511, W10/W35 °C, 5 K spread)
Rated heating output kW 37.1 47.8 78.6 106 134.1
Cooling capacity kW 29.7 39 64.2 85.9 109.6
Power consumption kW 7.4 8.8 14.5 19.6 24.6
Coefficient of performance ¡ in heating mode 5 5.4 5.4 5.4 5.5
Dimensions
Length mm 1848 1848 1848 2153 2153
Width (excl. anti-vibration fittings (casing)) mm 820 (750) 820 (750) 820 (750) 911 (850) 911 (850)
Height mm 1450 1450 1450 1650 1650
+ + + + ++ + ++ +
Energy efficiency class LT/HT** A /A A /A A /A A /A A /A+
++
Types BW 352.A027SA to BW 353.A198SA come fitted as standard with electronic soft starters with integral rotary field monitoring
* In W/W operation with intermediate circuit
** LT for B0/W 35 °C, HT for B0/W 55 °C
14/15
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 114.2 131.9 155 170.2 197
Cooling capacity kW 88.4 101.5 119.2 132 153.3
Power consumption kW 25.9 30.4 36.3 38.4 45.7
Coefficient of performance ¡ in heating mode 4.4 4.3 4.3 4.4 4.4
Performance data*
(to EN 14511, W10/W35 °C, 5 K spread)
Rated heating output kW 158 181.9 214.4 237 274.2
Cooling capacity kW 129 148 173.8 193.5 222.8
Power consumption kW 29 34.1 40.7 44.2 52
Coefficient of performance ¡ in heating mode 5.4 5.3 5.3 5.4 5.3
Dimensions
Length mm 2153 2153 2153 2816 2816
Width (excl. anti-vibration fittings (casing)) mm 911 (850) 911 (850) 911 (850) 911 (850) 911 (850)
Height mm 1650 1650 1650 1650 1650
++ + ++ + ++ + ++ +
Energy efficiency class LT/HT** A /A A /A A /A A /A A /A+
++
Types BW 352.A027SA to BW 353.A198SA come fitted as standard with electronic soft starters with integral rotary field monitoring
* In W/W operation with intermediate circuit
** LT for B0/W 35 °C, HT for B0/W 55 °C
Vitocal 350-G Pro
The Vitocal 350-G Pro with compact rotary Comprehensive equipment level and
screw compressors is a heat pump straightforward operation
manufactured in series with heating output The machine's control is supported by a
ratings above 1 MW and cooling capacities of PLC-based Vitotronic. Intuitive operation
up to 1490 kW. All models are available with of the 5.7 inch colour touchscreen allows
different compressors, which offer various parameter settings to be made quickly. The
benefits depending on application. touch function can also be used to directly
access a visualised display of the scheme
Single and two-stage versions and the internal refrigerant circuit. System
from 223 to 1128 kW data can be automatically saved up to 14 days Single stage version of the
Vitocal 350-G Pro with a heating
The single stage version covers heating retroactively.
output of 564 kW
output ratings up to 564 kW. A refrigerant
circuit with optimised design is equipped As an extended means of control, a Modbus
with large area plate heat exchangers on both interface can be used to provide external
the evaporator and condenser sides. Integral cascade control or for other options. To
output control is possible in stages of 25, 50, prevent any liquid evaporator medium from
75 and 100 percent. reaching the compressor in the event of a
power failure, all Vitocal 350-G Pro appliances
Two-stage version are equipped with a separate power pack.
The two-stage version (up to 1128 kW) This reliably closes the injection valves and
features two refrigerant circuits that work shuts down the machine in a controlled way.
separately, but that are supplied via a joint
tubular evaporator. Optional accessories
The standard heat pumps comprise a modular
The particularly efficient single-pass version frame design with a mounted control panel.
optimises evaporation temperatures. One Sound insulation sets are available as retrofit
four-stage output control unit per refrigerant option.
circuit enables eight partial loads of 12.5 up
to 100 percent. The machines can also be ordered with an
electronic soft starter.
Through balancing control, virtually identical
compressor runtimes are achieved, thereby
reducing maintenance cycles.
Specification
6
1 4 2
4
4
5
6
7
7
7
Energy from water at 4 °C Refrigerant circuit of a water/water heat pump with stainless steel tubular heat exchanger
This heat pump uses waste heat and, at the same time,
cools the data processing centre and appliance test beds
at the Viessmann head office in Allendorf
30/31
A waste water heat pump with 150 kW output for DHW heating
Air/water
heat pumps
The individual design of large Viessmann heat pumps and full in-house manufacturing
guarantee optimum interaction of all components.
Special heat pumps from Viessmann are built according to customer specifications
and factory tested for fault-free function.
Residential complex,
Cologne, Germany
Cooling capacity installed: 56 kW
Electrical output: 18 kW
Heating output: 74 kW
Special feature:
Dual mode system with Vitocrossal 300
gas condensing boiler, 105 kW
References
Keckeisen Akkumulatoren,
Memmingen, Germany
Cooling capacity installed: 119 kW
Heating output installed: 150 kW
Special features:
Concrete core activation and
radiating ceiling panels,
energy contracting
Steca Elektronik,
Memmingen, Germany
Cooling capacity installed: 384 kW
Heating output installed: 484 kW
Heat pumps: 2
Special features:
Use of waste heat,
energy contracting
38/39
The company
Viessmann Group
Copyright Viessmann
Duplication and alternative use only with prior written consent.
Subject to technical modifications.