Application Fields
AZP-RA AZP-RA-U
IPKZ-MS-RA IPKZ-E-RA
PM-U
(48/96)
ENES-4M
ENES-1
IPKZ-M-RA-TC IPKZ-RA UDP-300 KIP-PSS
Pulse Transformers
Rated output power, kW — from 0.3 to 5
Rated output current, A — from 6.3 to 100
Rated output voltage, V — 48/96
Supply voltage, V — 220 22
IPKZ-M-RA
Output voltage ripple, %, max — 1
Regulation range of output current and voltage,% — from 0 to 100
Measuring range of polarization and total potentials, V — from -4.5 to +4.5
The range of setting the total potential, V — from -3.5 to -0.5
Energy conversion efficiency in rated mode,%, min – 90
Power factor, min – 0,95
Service life, years, min – 15
A possibility of 100% backup of power modules
Ingress protection rating IEC 60529 – IP34
Climatic Design - medium low temperature version
IPKZ-E-RA
Test Points
Показатели
Parameter ЭНЕС-1
ENES-1 ЭНЕС-4М
ENES-4M ЭНЕС-5М
ENES-5M
Внутреннее
Internal электрическое
electrical resistance 0,1 - 2,5 1,0 0,5
сопротивление,
kOhm(kΩ), max), max кОм, не ENES-1
более
Переходноеelectrical
Transitional электрическое 15,0 10,0 10,0
сопротивление,
resistance, kOhmкОм
Потенциал
Potential withпоrespect
отношению
to theк 120 100 120
хлорсеребряному
silver chloride electrode, mV
электроду, мВ
Количество
The электролита,
electrolyte filling amount 120 800 260
заливаемого
into в корпус,
the casing, ml мл
Маркаof
Model кабель-выводов
output cable ПВ З*1,5 КГВЭВнг 2х4 ПВ 3*1,5
Установленный
Service срокmin
life, years, 15 25 3 ENES-4M
службы, лет, не менее
ESHS-S-RA
IPKZ-MC_RA
IPKZ-M-RA-TC
PAKM-40
P-BTTC
Galvanic Anodes Protection
We produce the whole range of Al, Mg, Zn galvanic anodes according to GOST,
specifications
Interflange galvanic
anodes P-KLA-15 P-KOM-3a UPBA
potential (total, polarization);
output current;
output voltage;
system voltage;
stabilization mode;
installation by stabilization parameter;
readings of metering devices;
working time;
protection time of the constructure;
deactivating/activating of the device;
local/remote mode;
backup/primary station;
unauthorized access;
connection with the control unit;
emergency situation (door condition, output cable break, ES cable break, short circuit,
network overvoltage).
The Effect of the Complex Usage of Cathodic
Crotection Systems
Increased safety
Visualization and
Reduced maintenance automation of
costs operating cathodic
protection system
Decreasing of the time processes
loses