Cable gland
Indication (Option “C”)
scale
Mounting backet
(Stainless steel) Spring
2
THE “USER FRIENDLY GENERATION“
The “User Friendly Generation” is no idle boast. BETA can – and always will – supply the best -
instrumentation for the given conditions.
Many years of close attention to our customer’s requirements have resulted in a vast experience
of virtually all known switch applications.
Major users all over the world, in all areas of industry, already enjoy the benefits of BETA’s “user friendly”
switches. BETA manufactures high quality instruments to meet all of your requirements.
The piston sensor is isolated from the process fluid by a diaphragm and static O-Ring seal and retained by
a process connection port. These (3) are the only process wetted parts and are available in an extensive
range of materials.
THE FEATURES
C E RT I F I C
SAFETY Safe, secure electrical hookup by clamp terminals. TEM AT
YS
Standard earth terminal.
IO
N
IP 66 enclosure.
Solid cover with gasket and captive screws.
IS O
RELIABILITY Highest Overrange protection. 90 01
Spring loaded piston, excellent resistance against shock
and vibration.
Flexible stainless steel mounting bracket:
No pipe strains on the instrument to cause shift of setpoint.
QUALITY SGS SGS certified Quality Assurance according to ISO 9001 - 2000 covers all switch
manufacturing, Engineering & Design.
ECONOMY A wide range of wetted process materials virtually eliminates the need for
costly chemical seals.
SERVICE The international BETA sales network backs up this high quality product with
equally high quality service.
3
GUIDE OF HOW TO SELECT YOUR BETA SWITCH
BETA uses a simple and logical model code system for easy, accurate product specification, project coordination,
efficient document handling and after sales service.
C3 - P304L - S1N - B1 - K1 - Y - X2
1 ENCLOSURES
2 RANGES
Type
P Pressure switch
D Differential pressure switch
V Vacuum switch
T Temperature switch
Sensor body
L Low pressure sensor body
M Medium pressure sensor body
H High pressure sensor body
F Fluid power sensor body (only as combination P…F)
D Double (D…D for Double differential)
Free of charge: BETA will add your tag no. on the nameplate and set the
pressure switches at desired setpoint if this is requested
on your order.
(Temperature switches can also be set at an additional charge)
* For standard BETA switch (Switch with “K1” switching element and “B1” diaphragm/O-Ring).
4
PRESSURE SWITCHES
1 ENCLOSURES
C3 - P304L - S1N - B1 - K1 - Y - X2
W3 - D...L
M0
C - D...M
C - D...L
W3 - D...M W3 - D...H
C - D...H
Enclosure “B2” only available with Range codes P…H, P…F and V…H.
2) Includes 316 SS sensor body and adjusting nut.
3) D...L and D...H type only.
4) All differentials except D...D-type.
5
PRESSURE SWITCHES
“Ranges” given here are valid for setpoints at increasing pressures (vacuum) in psi (in. wc). The “Deadband” values are the max. possible values for
a standard micro & diaphragm/ O-ring and varies nearly linear with setpoint between indicated limits of range and should be multiplied by deadband
multipliers as given in section 4 and 5, where appropriate. (For Fluid Power multiplier acc. to section 5 only). Selection of other than standard micro
may influence lower end of range. For deadband calculation in combination with “SR”- and “SP”- micro, Consult Factory.
1) Only available with L1 –microswitch element.K1/G1 possible consult factory). Not available on M-series switches.
MAX.
ADJUSTABLE RANGE MAX. DEADBAND PROOF PRESSURE
RANGE CODE OVERRANGE PRESSURE
psi bar psi bar psi bar psi bar
P 904 F 147 - 800 12 - 55 50.8 - 87.0 3.5 - 6.0
P 906 F 232 - 1880 16 - 130 58.0 - 123.5 4.0 - 8.5
9400 650 10160 700
P 908 F 290 - 4350 20 - 300 87.0 - 174.0 6 - 12
P 918 F 435 - 7840 30 - 540 218.0 - 450.0 15 - 31
1) For setpoint around zero bar gauge, consult factory. (Note: Setpoint stability around zero bar cannot be guaranteed)
6
PRESSURE SWITCHES
NOTES:
1) Ranges and deadbands are given at 50% of Max. Static pressure. All differential pressure sensors are sensitive to static pressure,
3) P301L-D and D…L can withstand a differential pressure P-low max. 1 bar above P-High.
4) D…M, D…H and D…D can sustain full High and Low-side reversal.
IN THE FOLLOWING TABLE THE ESTIMATED INFLUENCE FOR INCREASING STATIC PRESSURE IS GIVEN.
SETPOINT DEADBAND
SENSOR
psi bar psi bar
P 301 L - ... D ≈ + 0.04 InchWC/Psi ≈ + 0.1 mbar/bar ≈ + 0.04 InchWC/Psi ≈ + 0.1 mbar/bar
D...L - 0.3 InchWC/Psi - 0.7 mbar/bar ≈ - 0.04 InchWC/Psi ≈ - 0.1 mbar/bar
D...M ≈ + 1.2 InchWC/Psi ≈ + 3 mbar/bar 4 InchWC/Psi + 10 mbar/bar
D...H -0.8 InchWC/Psi - 2 mbar/bar ≈ -0.2 InchWC/Psi ≈ - 0.4 mbar/bar
Example: D…H-type Diff. setpoint: 1 bar (1000 mbar).
If static pressure increases 10 bar Diff.setpoint will be (10 x – 2 mbar ) = - 20 mbar less = 980 mbar.
NOTE: For vacuum differential application consult your BETA Switch Representative.
7
PRESSURE SWITCHES
3 PROCESS CONNECTIONS
C3 - P304L - S1N - B1 - K1 - Y - X2
L&M
A1N A1B B1N B1B
1/4”F D...L / M S1N S1B M1N M1B
H
D...H / D
F
L&M
1/2”F A2N A2B S2N S2B B2N B2B
D...L / M M2N M2B
H
L, M & H
1/2”M S7N S7B M7N M7B
D...L / M
M&H
1”M S8N S8B
D...M
Other materials such as P.V.C., Hastelloy, 316 SS Ti, Titanium etc. and other sizes and (Teflon lined) flanged connections are available.
1) Vacuum switches: Process conn. size max. 1/2”. Vacuum piston & spring (both wetted) standard in 316 SS.
2) Standard process connection for “L”ow & “M”edium pressure sensor body : A1N or A1B
“H”igh pressure sensor body : S1N or S1B
“F”luid power pressure sensor body : B1N or B1B
Differential switches: D…H, D…D : S1N or S1B only
D…L : A1N or A1B; For Low side only
High side; Only “L”-sensor connection
NOTES: Process connection according to NACE standards are available, consult your BETA Switch Representative.
NPT connections are tapered; BSP are parallel threaded.
8
PRESSURE SWITCHES
4 DIAPHRAGM / O-RINGS
C3 - P304L - S1N - B1 - K1 - Y - X2
DIAPHRAGM/ DEADBAND
DIAPHRAGM 6) O-RING USE 1)
O-RING CODE MULTIPLIER
1) Wetted parts are suggested for use on the service indicated. However they do not constitute a guarantee against corrosive or permeation
1) since processes vary from plant to plant. Empirical experience by users should be the final guide. The diaphragm / O-Ring combinations are
1) for process temperatures of -22 °F to +176 °F, unless otherwise indicated. For process temperatures beyond these limits please contact
1) your BETA Switch Representative.
2) Switches for fluid power applications are limited to these options (O-Ring only with 316 SS piston).
3) Only for 1/4” & 1/2” process connections. Not available on vacuum switches. For other sizes and materials, consult your
1) BETA Switch Representative.
4) PTFE O-Ring not suitable for vacuum switches or vacuum conditions. (Wetted internal spring of Co-Cr-Ni alloy, comparable with Elgiloy).
5) For process temperature > 212 °F, consult your BETA Switch Representative.
6) Other diaphragm materials like Hastelloy available, consult your BETA Switch Representative.
Note:
Wetted parts are not guaranteed against corrosion or permeation since processes vary from plant and concentration of harmful fluids,
gasses or solids vary from time to time in a given process.
Empirical experience by users should be the final guide and alternate materials based on this are generally available.
9
DIFFERENTIAL PRESSURE SWITCHES
4 DIAPHRAGM / O-RINGS
C3 - D352H - S1N - P1 - K1 - Y - X2
W3 - D...L
C - D...M
C - D...L
W3 - D...M W3 - D...H
C - D...H
Differential Pressure Switches can use the same Diaphragm/O-ring combinations as Pressure Switches but
we have to consider following:
Note: Deadband Multiplier for Diaphragm/O-Ring and microswitch element is the same as for pressure switch.
10
PRESSURE AND TEMPERATURE SWITCHES
5 SWITCHING ELEMENTS
C3 - D352H - S1N - P1 - K1 - Y - X2
1) For D.P.D.T. action second code figure should be specified as “2” (Example: K1 = S.P.D.T ./ K2 = D.P.D.T.).
7) For pneumatic element ask for our separate Air Relay documentation.
* Subminiature.
** DC rating not U.L. listed, although experience and third party testing confirm the DC voltage ratings.
Consult your BETA Switch Representative.
11
PRESSURE AND TEMPERATURE SWITCHES
ENCLOSURE
SWITCHING
C1, C2, C3, C4, C8, C9 M0 W3, W8, W9
ELEMENT
Internal Earth Ground Internal & External
Earth Ground Terminal via wired lead Earth Ground Terminal
SE
SG
SP
SR SCREW.TERM.BL.
SV 4-WAY TERM. BL.
(SINGLE SWTCHING ELEMENT)
G1 3-WAY
H1 TERMINAL BLOCK
S. P. D. T.
K1
4-WAY
L1
TERMINAL BLOCK
U1
O1
N1
F1
M1 3-WAY 4-WAY
Y1 TERMINAL BLOCK 4-WIRE LEADS TERMINAL BLOCK
Z1
F2
(DOUBLE SWITCHING ELEMENT)
M2 6-WAY 7-WAY
Y2 TERMINAL BLOCK 7-WIRE LEADS TERMINAL BLOCK
Z2
D. P. D. T.
G2
H2
6-WAY
K2
TERMINAL BLOCK
U2
O2 7-WAY
N2 TERMINAL BLOCK
NOT POSSIBLE
12
PRESSURE SWITCHES
6 OPTIONS
C3 - D352H - S1N - P1 - K1 - Y - X2
S Stainless steel Tag-clipped to enclosure. Tag has 3 lines (20 characters per line).
V Fungicidal varnish coating (internal).
Y Epoxy coating of switch (external). Only in combination SS 316 process connection.
7 SPECIALS
C3 - D352H - S1N - P1 - K1 - Y - X2
We can incorporate numerous specials to meet your requirements. These special requirements are
indicated by the letter “X” in the model code or at the end of the model number, followed by a figure
showing the number of specials.
Example:
“X1” at the end of model “X2” at the end of model Details of each special
reference means one reference means two must always be
special. specials have been specified completely
incorporated. on enquiries and orders.
13
SELECT YOUR BETA SWITCH
1 ENCLOSURES
C3 - P506H - S1B - S2 - K1 - Y - X2
2 RANGES
C3 - P506H - S1B - S2 - K1 - Y - X2
4 DIAPHRAGM / O-RINGS
C3 - P506H - S1B - S2 - K1 - Y - X2
5 SWITCHING ELEMENTS
C3 - P506H - S1B - S2 - K1 - Y - X2
14
TEMPERATURE SWITCHES
15
TEMPERATURE SWITCHES
1 ENCLOSURES
C3 - T548H - D00 - S0 - K1 - Y - X2
C - D...H
M0 - T
C
B2
B2 - T
W3
ELECTRIAL
ENCLOSURE CODE CLASSIFICATION MATERIAL EARTH TERMINAL TERM. BLOCK
COND. CONN.
Hirschmann Plug conn. Standard
B2 Weathertight Miniature (IP65) Aluminium Not applicable
DIN 43650-A (Via plug)
C1 PG 13.5
Weathertight
C2 M20 x 1.5
(IP66) Aluminium
C3 CSA & FM Type 4X 3/4” NPT (F) Standard
Standard
C4 Intrinsically safe 1/2” NPT (F) (Internal)
(with Option “I”)
C8 M20 x 1.5
Ex ia IIC T6 316 SS 1)
C9 3/4” NPT (F)
Miniature Explosion-proof
EEx d IIC T6 Standard
Wire leads 1)
M0 (IP65) 316 SS (Wire leads Not applicable
02 ATEX 2189X (20”Length)
20”Length)
CSA & FM Pending
Explosion-proof
W3 ATEX & IECEx: 3/4” NPT (F) Aluminium
Ex d II C T6...T5
Standard
W8 Ex tD A21 T100°C, IP66 M20 x 1.5 Standard
CSA: Ex d II C T6..T5
In- & External
316 SS 1)
FM: AExd II C T6..T5
W9 3/4” NPT (F)
IP66 NEMA Type 4X
16
TEMPERATURE SWITCHES
2 RANGES
C3 - T548H - D00 - S0 - K1 - Y - X2
W3 - Temp. Direct
M0 C - Temp. Capillar
W3 - Temp. Capillar
1) In case process temperature > 285 °F, Direct mount sensing bulb is not recommended.
3) For deadband calculation in combination with “SR”- and “SP”- micro, Consult Factory.
17
TEMPERATURE SWITCHES
3 SENSOR BULBS
C3 - T548H - D00 - S0 - K1 - Y - X2
PROCESS
SENSOR CODE TYPE OF TEMPERATURE SENSING BULB
CONNECTION
All 316 SS stainless steel sensor, capillary (304 SS armored) and compression fitting.
1) Not in combination with range T588H (+320/+572 ˚F), not recommended with T568H in case of process temperature >284 ˚F.
2) Length of capillary should be specified, consult your BETA Switch Representative.
4 DIAPHRAGM / O-RINGS
C3 - T548H - D00 - S0 - K1 - Y - X2
5 SWITCHING ELEMENTS
C3 - T548H - D00 - S0 - K1 - Y - X2
18
TEMPERATURE SWITCHES
6 OPTIONS
C3 - T548H - D00 - S0 - K1 - Y - X2
C Cable gland (weather proof IP65, EExe, EExi or EExd in acc. with classification of enclosure).
I Intrinsically safe application (EEx)i. Only on “C”-Series.
S Stainless steel Tag-clipped to enclosure. Tag has 3 lines (20 characters per line).
V Fungicidal varnish coating (internal).
Y Epoxy coating of enclosure and sensorbody (external).
7 SPECIALS
C3 - T548H - D00 - S0 - K1 - Y - X2
Example:
“X1” at the end of model “X2” at the end of model Details of each special must
reference means one reference means two always be specified
special. specials have been completely on enquiries
incorporated. and orders.
19
BETA SWITCHES FOR HAZARDOUS AREA
BETA offers complete line of switches for (classified) hazardous locations!
The “BETA Switch”, well known as a safety instrument, adds an extra dimension to industrial safety by
having area approval up to the highest classification by ATEX, IECEx, CSA and FM.
For W-Series
ATEX: Cert.: KEMA 02 ATEX 2186
Ex II 2G Ex d II C T6 (-40 to +158 °F)...T5 (-40 to +176 °F)
Ex II 2D Ex tD A21 IP66 T100 °C
CSA: Cert.:1873316
Class I, Div. 1, Groups B, C, D T6...T5 (T6: 158 °F/ T5: 176 °F)
Class II, III, Div.1, Groups E, F and G
Ex d II C T6...T5
FM: Cert.:3028962
Class I, Div. 1, Groups A, B, C and D
Class II, Div. 1, Groups E, F and G
Class III, T6...T5
AExd IIC T6...T5, IP66 NEMA Type 4X
CSA: Cert.:1891054
Acc. to Class 2258 04
IS Class I, II, III, Div.1, Groups A, B, C, D, E, F and G
Ex ia IIC T6 T85 °C (185 °F)
Enclosure Type 4X
FM: Pending
20
BETA SWITCHES FOR HAZARDOUS AREA
21
BETA SWITCHES FOR HAZARDOUS AREA
W-Series -ATEX, IECEx, CSA and FM approved (see also page 20)
"W"-Series "W"-Series
ATEX approved: KEMA 02 ATEX 2186 CSA No.: 1873316 IECEx No.: KEM07.0034
* For Gas : Ex II 2G Ex d IIC T6 Ex d IIC T6...T5 Ex II 2D Ex tD A21 T100°C IP66
For Dust : Ex II 2D Ex tD A21 IP 66 T100°C FM No.: 3028962
AEx d IIC T6...T5
(For more information see also page 20)
22
BETA SWITCHES FOR HAZARDOUS AREA
“C”-Series
BETA "C" - Series with option "I" for intrinsically safe systems
BETA has its “C”-Series switches with option “I” certified by KEMA
acc. to NEN EN IEC 60079-0 / EN 50 020 for Ex II 1G/D EEx ia IIC T4...T6 T 85 °C or
Ex II 2G/D EEx ib IIC T4...T6 T 85 °C.
23
BETA DIFFERENTIAL PRESSURE SWITCHES
The “USER FRIENDLY” generation of BETA switches offers you a complete range of Differential
Pressure Switches.
24
BETA DIFFERENTIAL PRESSURE SWITCHES
* “Clean fluids and gases”, must be free of particles > 40µm, filters (not included) are recommended in case of contaminated medium.
A differential pressure switch is a “dead end” instrument, so a simple filter with fine mesh will work.
25
BETA PRESSURE & TEMP. SWITCH - CERTIFICATIONS
EXPLOSIONPROOF CERTIFICATIONS
ATEX – Ex II 2G Ex d IIC T6...T5 for W-Series.
Ex II 2D Ex tD A21 T100°C
ATEX – EEx ed IIC T6 for M-Series.
ATEX – Ex II 1G EEx ia IIC T4...T6 for C-Series (intrinsically safe).
Ex II 2G EEx ib IIC T4...T6
II 1D T85 °C (185 °F)
II 2D T85 °C (185 °F)
ATEX – EEx II 2 G c T6 for Air Relay SA/SB.
FM – AExd IIC T6...T5 for W-Series.
CSA – Exd IIC T6...T5 for W-Series.
CSA – Ex ia IIC T6 T85 °C (185 °F) for C-Series (intrinsically safe).
IECEx – Ex d IIC T6...T5 for W-Series.
Ex tD A21 T100 °C
IECEx – Zone O Ex ia IIC T6 for C-Series intrinsically safe.
Ex ia D 20 IP66 T85 °C
And more available for different countries like Japan, Korea, South-Africa, Australia etc..
MARINE APPROVALS
RINA for B- and C-Series.
G.L. for C-Series.
26
DIMENSIONS
“C.”-Series: Pressure & Vacuum “W.”-Series: Pressure & Vacuum
TYPE SENSOR A
L 155
PRESSURE M 155
SWITCH H 155
F 163
L 175
VACUUM
M 175
SWITCH
H 169
Dimensions given here are for 1/4” and 1/2” (F) process connections: For “H”-sensor with 1/2” (F) add 4 mm
on “A” dimension. Sizes in mm, tolerances ± 1,5 mm.
27
DIMENSIONS
“C.”-Series: Differential “D...L” “C.”-Series: Differential “D...M”
28
DIMENSIONS
“W.”-Series: Differential “D...L” “W.”-Series: Differential “D...M”
Dimensions given here are for 1/4” and 1/2” (F) process connections: For “H”-sensor with 1/2” (F) add 4 mm
on “A” dimension. Sizes in mm, tolerances ± 1,5 mm.
29
DIMENSIONS
“M0”-Series: Differential “D...H” “C.”-Series: Temperature “Direct” mount
Dimensions given here are for 1/4” and 1/2” (F) process connections: For “H”-sensor with 1/2” (F) add 4 mm
on “A” dimension. Sizes in mm, tolerances ± 1,5 mm.
30
ACCESSORIES
NOTES:
1. “C10” requires special Thermowell. Consult your BETA Switch Representative.
2. BETA Thermowells to be ordered as separate item. Do not include Thermowell code into the switch code.
3. Special Thermowell possible. Consult your BETA Switch Representive.
31
Pressure & Temperature Switches
Weathertight switches ("C"-Series) - Optional: Intrinsically safe Exproof 316 SS offshore switches ("M"-Series)
CORPORATE HEADQUARTERS:
K-TEK LLC
18321 Swamp Road
Prairieville, LA 70769 USA
TELEPHONE
(225) 673.6100
FAX
(225) 673.2525
E-MAIL
sales@ktekcorp.com
INTERNET
www.ktekcorp.com
We reserve the right to change models and specifications without prior notice.
BETA products are manufactured at BETA B.V. Verrijn Stuartlaan 22, NL-2288 EL Rijswijk The Netherlands
c BETA B.V. Rijswijk The Netherlands SP.210.G/US/07/10/1M
32