Array Box: Protect and Enhance The Performance of Your Photovoltaic Installation
Array Box: Protect and Enhance The Performance of Your Photovoltaic Installation
Array Box: Protect and Enhance The Performance of Your Photovoltaic Installation
True bankability
• Warranty from a trusted partner with 178 years of experience
• World leader in industrial power drives, UPS and electrical distribution
• Strong service infrastructure worldwide to support your global needs
Flexible
• Fits every PV plant design and module technology with a range of
8/16/24 input channels and 160/300 A STC output currents
• Range available with and without monitoring of string currents
• On-field weather sensors easily connected inside the Array Box to avoid
any additional equipment
Easy to service
• Conext ControlTM identifies the service needs of the Array Box
• Motorized switch controlled remotely by Conext Control accelerates
lock-out / tag-out procedure and allows an easy return to operation
Easy to install
• Mounting on a support bracket or on a plinth for independence to the
racking system, or attached to the racking system for less civil work
• Capabilities to directly connect up to 2 PV string cables and 2 DC
output cables per polarity
Product applications
solar.schneider-electric.com
Array Box
Device short name AB08-160 AB16-160 AB16-300 AB24-300
Electrical specifications
DC inputs
Number of inputs 8 16 16 24
Max. voltage in open circuit 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc
Max. input current in short circuit 25 A 25 A 25 A 25 A
Max. input current in short circuit at STC 20 A 20 A 20 A 20 A
DC output
Max. output current in short circuit
at ambient temperature < 40°C 200 A 200 A 375 A 375 A
at ambient temperature < 45°C 180 A 200 A 350 A 350 A
at ambient temperature < 50°C 160 A 200 A 315 A 315 A
Max. output current in short circuit at STC
at ambient temperature < 40°C 160 A 160 A 300 A 300 A
at ambient temperature < 45°C 145 A 160 A 280 A 280 A
at ambient temperature < 50°C 125 A 160 A 250 A 250 A
AC supply*
Voltage at 50/60 Hz 230 V + 10 / -15% 230 V + 10 / -15% 230 V + 10 / -15% 230 V + 10 / -15%
Environmental specifications (in operation)
Ambient temperature -25°C to +50°C, above* -25°C to +50°C, above* -25°C to +50°C, above* -25°C to +50°C, above*
Relative humidity 0 to 100% condensing 0 to 100% condensing 0 to 100% condensing 0 to 100% condensing
Altitude 0 to 2000 m without derating 0 to 2000 m without derating 0 to 2000 m without derating 0 to 2000 m without derating
Mechanical specifications
Enclosure
Type Outdor use, full insulating cabinet (polyester reinforced with fiberglass)
Fire withstand Self-extinguishing (does not propagate fire during the glow-wire test at 960 ºC), halogen-free
Color RAL 7032, grey RAL 7032, grey RAL 7032, grey RAL 7032, grey
Product
Dimensions (H x W x D) 84.7 x 63.6 x 30.0 cm 105.6 x 85.2 x 35.0 cm 105.6 x 85.2 x 35.0 cm 105.6 x 85.2 x 35.0 cm
(33.3 x 25.0 x 11.8 in) (41.6 x 33.5 x 13.8 in) (41.6 x 33.5 x 13.8 in) (41.6 x 33.5 x 13.8 in)
Weight 33.0 / 37.0 / 40.0 kg 58.0 / 62.0 / 65.0 kg 63.0 / 67.0 / 71.0 kg 67.0 / 71.0 / 75.0 kg
(protect / monitored / controlled) (72.8 / 81.6 / 88.1 lb) (127.9 / 136.7 / 143.3 lb) (138.9 / 147.7 / 156.5 lb) (147.7 / 156.5 / 165.3 lb)
Mounting Floor-standing on support, wall-fixing or attached with lugs (must be installed protected from direct sunshine)
Degrees of protection IP54 (IP55 with optional covers), IK10
Features
Protection
DC inputs overcurrent protection Protection on both polarities, gPV fuses, size 10 x 38 (fuses not provided with product)
DC overvoltage protection Surge arrester, 1000 Vdc, type 2, Imax 40 KA
AC supply overvoltage protection* Surge arrester, 230 Vac, type 2, Imax 40 KA
Electric shock protection Class II equipment
Monitoring and control*
DC input currents* 0 to 30 A, accuracy +/- 0.5% full scale (one measurement per input)
DC voltage* 0 to 1000 V, accuracy +/- 0.5%
Internal temperature** -30 to +120°C, accuracy +/- 1°C
Temperature sensor input*** -30 to +120°C, accuracy +/- 1°C, for external PT1000 2 wires temperature sensor
2 x irradiance sensor inputs*** 0 to 1600 W/m², accuracy +/- 0.5% full scale, for external 4-20 mA irradiance sensor
Communication** Profibus DP / RS485 and Modbus RTU / RS485 link
Switch disconnector remote control**** Motor pack and MX shunt release
Compliance
LV switchgear IEC / EN 61439-1 and 61439-2
CE marking According LV directive 2006 / 95 / CE and EMC directive 2004 / 108 / CE
Available models
Protect: protection only PVSAB31101 PVSAB31201 PVSAB31301 PVSAB31401
Monitored: protection and monitoring PVSAB31111 PVSAB31211 PVSAB31311 PVSAB31411
Controlled: Protection, monitoring
PVSAB31121 PVSAB31221 PVSAB31321 PVSAB31421
and switch control
Optional weather module* PVSAB31021 PVSAB31021 PVSAB31021 PVSAB31021
Specifications are subject to change without notice. *Contact Schneider Electric. **For monitored and controlled models. ***With optional weather sensors connection module. ****For controlled models.
© 2014 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. DS20141002 _ArrayBox