Manual Bombas
Manual Bombas
Manual Bombas
FOR INSTALLATION
OPERATING,
AND
MAINTENANCE.
Dosing pump
PRIMEROYAL
PN117(140)S(W)38.1UT160TX/ VV1.Z
This manual should be made available to the person responsible for installation,
operating and maintenance.
REPRESENTED BY:
I - DESCRIPTION
I - 1. Unpacking and storage
I - 2. Description
I - 3. Operating principle of the mechanical assembly
I - 4. Operating principle of the liquid end
I - 5. Safety and health instructions
II - INSTALLATION
II - 1. Hydraulic installation
II - 2. Drip collection
II - 3. Handling
II - 4. Setting up
II - 5. Electrical installation
III - START UP
III - 1. Procedures before start up
III - 2. Start up
III - 3. Failures on start up
III - 4. Operation - Schedule of checks and maintenance operations
IV - ROUTINE MAINTENANCE
IV - 1. Oil change
IV - 2. Other maintenance operations
IV - 3. Tracing causes of failure
IV - 4. Ordering spare parts
V - PREVENTIVE MAINTENANCE
GUARANTEE
REPRESENTED BY:
UNPACKING
The packaging must be carefully examined on receipt in order to ensure that the contents have not
sustained any obvious damage. Precautions must be taken when opening the packaging in order to
avoid damaging accessories which may be secured inside the packaging. Examine the contents and
check them off against the delivery note.
STORAGE PRECAUTIONS
Equipment shall preferably be stored in its original packaging and protected from adverse
weather conditions.
- Grease all visible unpainted sections. Rubber parts (such as semi-flexible couplings) must be
protected from sunlight and sudden temperature changes.
- Store the pump in its original packaging. In addition, packaging in heat-sealing plastic cover
and dessicant bags must be provided for. The quantity of dessicant bags should be adapted to
the storage period and to the packaging volume.
- Store protected from adverse weather conditions.
I - 2. DESCRIPTION
The PRIMEROYAL Pump is a compact electro-mechanical metering pump, oil-lubricated with a sealed
housing, allowing adjustment of its capacity when stopped or in operation.
It is designed for industrial operation in continuous mode.
It is made up of the following items :
• a driving device consisting of a motor ,
• a mechanical assembly ,
• a liquid end assembly
REPRESENTED BY:
M0226001 1 /7
I - 3. OPERATING PRINCIPLE OF THE MECHANICAL ASSEMBLY
Drawing 1066136410
The movement of rotation of the motor is transmitted by the worm [052] to the tangent wheel
The system of rod [014] and eccentric [016A] transforms the rotative movement in a linear movement
The crosshead [010] connected to the connecting rod [014] move with an adjusting linear stroke. The
stroke of the crosshead [010] depends to the position of the slide [016] and the eccentric female
[016A]
The personnel responsible for installing, operating and maintaining this equipment must become
acquainted with, assimilate and comply with the contents of this manual in order to:
• avoid any possible risk to themselves or to third parties,
• ensure the reliability of the equipment,
• avoid any error or pollution due to incorrect operation.
Any servicing on this equipment must be carried out when it is stopped. Any accidental start-up must
be prevented (either by locking the switch or removing the fuse on the power supply line).
A notice must be attached to the location of the switch to warn that servicing is being carried out on
the equipment.
During oil changing operations, the waste oil must be collected in a suitable receptacle. Any overflow
of oil which may result must be removed using a degreasing agent suitable for the operating
conditions.
Soiled cleaning cloths must be stored in suitable receptacles. The oil, degreasing agent and cleaning
cloths must be stored in accordance with the rules on pollution.
Switch off the power supply as soon as any fault is detected during operation: abnormal heating or
unusual noise.
Special care has to be taken for chemicals used in the process (acids, bases, oxiding/reducing
solutions, ...).
REPRESENTED BY:
M0226001 2 /7
8 7 6 5 4 3 2 1
053
K (1 : 2)
431
435F
A A
E E
037
I (1 : 1)
072A
H (1 : 2) 434B D
438F 435E 068B 010 406
D
068
A-A
435A 016A
439F
016
439D
439B B
B C
C 439C
014 037A 052 438I 438K 438A 037B 434 438H 081A
438E
B-B 438J 435D 435F 081
439A
019C
435C
439
435J
434A
008 438C
435F
B 068A B
072 F (1 : 1)
056
435F
26.05.05 EMISSION INITIALE YChevallier DDeparrois 00
Date Texte de la modification - Modification Dessiné-Drawned / Visa Vérifié-Checked / Visa Revision
406
PRIMEROYAL N A
A 435G ENS MECANIQUE A PISTON SIMPLEX
068D 438B 072C SX PLUNGER MECHANICAL ASSEMBLY
432B 072B 432B 435H
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
434C Tel : +33 (0)2 32 68 30 00
A2 1:4 1/ 1 Fax : +33 (0)2 32 68 30 93 106.6136.410
Propriété exclusive - Communication et reproduction interdites. All rights reserved - Copyright DOSAPRO MILTON ROY COMPANY
8 7 5 1 SOLIDWORKS
6 4 3 2
PART II - INSTALLATION
II - 1. HYDRAULIC INSTALLATION
All the information concerning the hydraulic installation of a metering pump is detailed in a volume,
« Generalities about dosing pumps installation ». You should consult that manual to define the
installation required for your application. However the main items are describe hereafter.
GENERAL
• Piping layout
• There must be no swan-necks or stagnant volumes which can trap air or gas.
• Stresses due to incorrect alignment of piping with respect to the centreline of valves must be
avoided as far as possible.
• Remove burrs and clean the piping before fitting.
• It is advisable to provide for a calibrating chamber in order to calibrate the pump in service
conditions.
• Provide for a filter with suitable mesh size upstream of the pump.
• Check whether the diameter and length of pipe are compatible with the pump's maximum
capacity.
•
• Provide for a safety valve on the discharge pipe, designed to protect the installation.
• It is advisable to install a priming valve on the discharge circuit in order to make starting and
maintenance of the pump easier.
•
1 Tank 6 Utilization
2 Suction circuit isolating valve 7 Priming valve
3 Calibrating chamber 8 Safety valve
4 Pump 9 Return
5 Discharge circuit isolating valve 10 Filter
M0226001 3 /7
REPRESENTED BY:
• It’s recommended to install a drain system to collect the leakage and the drip, especially if the
liquid pumped is harmful
•
II - 3. HANDLING
The lifting equipment must be compatible with the motor weight (Refer to the motor signaletic plate).
Fit a sling in each ring on the motor.
Check that the motor is correctly balanced before starting to move it.
II - 4. SETTING UP
Pump Installation
Fix by the fixing holes the pump to an horizontal support correctly dimensioned. Leave enough clear
space around the pump to be able to carry out servicing operations and adjustments.
Pumps installed outdoors must be protected by a shelter (according to the climatic conditions).
Noise level, in dB (A) < 75
II - 5. ELECTRICAL INSTALLATION
Check the specifications of the motor and compare them with the voltage available on your installation
before making connections. Connect up the motor in accordance to the indications specified in the
connecting box.
Check the motor rotation as indicated on the motor spacer
Do not forget to connect the earth terminal of the motor [PE] to the equipment earth
conductor.
The electrical protection for the motor (fuse or thermal protection) must be suitable for the motor's
rated current.
M0226001 4 /7
REPRESENTED BY:
Special care has to be taken for chemicals product used in the process (acids, bases, oxyding
/reducing solutions, ...).
• Check the pump fixation(Chapter II - 4.).
• Fill the housing with the lubricating oil (Chapter IV-1)
• Check the opening of all isolating valves installed on the suction and discharge circuits.
Disconnect discharge circuit ( caution to the liquid pumped). This procedure is to verify that there is
liquid present (pump is installed in flooded suction), or to prime the pump (pump installed in suction
lift).
• Check that the pump capacity is set to "0%" (hand-knob).
III - 2. START UP
• Once all the checks and procedures described in the previous section have been carried out,
start up the pump.
• Check visually and by listening. (In particular, check that there are no suspicious noises).
• Make sure that the hand-knob is unlocked.
• Adjust the pump capacity gradually from 0 % to 100% and control the liquid output at priming
valve.
• As soon as the liquid to be pumped flows out of the priming valve, priming on the process side
has been achieved. Close the priming valve or reconnect the discharge pipe, as applicable.
• Once the priming is obtained, adjust the pump to the desired capacity.
• Lock the hand-knob with the locking screw
• The pump capacity is incorrectly adjusted: adjust the capacity to the desired value and lock
the hand-knob.
• The suction power is insufficient (pipe cross-section too small or pipe too long): replace the
pipe with ones that have a larger cross-section or install the pump in flooded suction.
• The leak -tightness of suction pipe is unsatisfactory.
• The viscosity of the liquid is incompatible with the pump's capabilities.
REPRESENTED BY:
• The stroke adjustment of debit of the pump is incorrect: to adjust the debit to the wanted value
• A syphoning phenomen is observed: check if the suction pressure is not superior to the
discharge pressure . So necessary, to place a back-pressure valve on the discharge line.
•
•
The capacity is variable
• This problem may be due to particles from the piping which interfere with the operation of the
valve assemblies: clean the piping and the valve assemblies (by checking the assembly sequence
of different components).
•
• The programme of checks and maintenance operations depends on the conditions in which
the equipment is used. For this reason, the following frequencies are given as an example only.
Individual users should adapt these frequencies to their own specific operating conditions.
** Our Technical Assistance Department staff is available for any maintenance matters on site (see
DOSAPRO adress at the end of this manual).
A model maintenance sheet is shown hereafter to help you ensure follow-up of your servicing actions
(checking or maintenance).
M0226001 6 /7
REPRESENTED BY:
REPRESENTED BY:
M0226001 7 /7
To avoid any risk of burning by the hot oil, protective gloves must be used..
• Perform the first oil change after 2000 hours' operation. Subsequent oil changes will be carried
out every 8000 hours operation or every 1 year
• Disconnect the pump electrically, check that the equipment cannot be switched on
accidentally. Position a notice at the location of the switch.
• Unscrew the plug and drain the oil into a tray. Degrease the plug and screw it into place.
• Remove any overflow of oil immediately with a suitable degreasing agent for the
operating conditions.
• Fit the plug [R1] and fill up the housing to the middle of the oil level indicator [L1] with
a mechanical oil suitable for service conditions.
• Drain also the liquid end spacer and the displacement chamber
• Fit the plug [R2] and fill up the housing to the middle of the oil level indicator [L2] with
a hydraulic oil. Fill up the displacement chamber by the safety valve hole
REPRESENTED BY:
Equivalencies :
Hydraulic oil FUCHS Renolin Extra 32S Part number : 437 0013 033N
Equivalencies :
BP HLPD 32
CASTROL HYSPIN VG 32
ELF OLNA 32
FINA CIRKAN 32
IGOL SONHYDRO 32
MOBIL DTE 24
SHELL TELLUS 32
TOTAL AZOLLAS ZS 32
ESSO NUTO H 32
REPRESENTED BY:
M0202001a
IV - 2. OTHER MAINTENANCE OPERATIONS
This is a question of determining the straight line representing the pump's capacity according to its
adjustment. Four measurements are sufficient (adjustment at 100%, 75%, 50% and 25%).There are
two possible methods:
If the pump is installed in pressurizing mode
Measure the volume of pumped liquid in a calibrating chamber for a given period of time. It may be
necessary to reproduce actual operating conditions (suction pressure).
The first method is recommended. In addition, this method avoids placing the operator in contact with
the liquid, which is important if the pumped liquid is hazardous. For a precise check, it may be
necessary to use an electromagnetic flow-meter.
• The quantity of lubricating oil is incorrect: trace the leak (see Chapter IV - 2.)
• The quality of the lubricating oil is incorrect. Check the date of the last oil change and the
specifications of the oil used.
• The pump is used in conditions it was not designed for.
REPRESENTED BY:
M0202001a
PROBLEMS WITH FLOW RATE
• The pump capacity is adjusted to « 0 % » : Adjust the capacity to the desired value and lock
the hand-knob.
• The liquid end is not primed: release the pressure on the discharge pipe and prime the liquid
end, or check the leak-tightness of the suction circuit.
• The balls of the valve assemblies are blocked by particles: clean or replace the valve
assemblies.
• First, check whether the presence of the particles in the valve assemblies is normal and take
corrective action if necessary.
• If the problem is not solved check the mechanical assembly and liquid end functioning
• The pump capacity is incorrectly adjusted: adjust the capacity to the desired value and lock the
hand-knob.
• The valve assemblies are blocked by particles: clean or replace the valve assemblies.
• Information on the pump: type and contract number. These two items of information are shown
on the identification plate mounted on the pump.
• Information on the spare part: reference, description and quantity. These items of information
are specified in the spare parts list supplied with the pump.
You will find the phone and fax number of the Spare Parts Department at the end of this document
M0202001a
PART V - PREVENTIVE MAINTENANCE
V-1. GENERALITIES
The preventive maintenance consists in replacing the wear parts included in a "spare parts kit". This
kits are available on request at the spare part department (chapter IV -4)
The corresponding action is detailed in the chapter VI and VII : Servicing of the mechanical assembly
and servicing of the liquid end
* Approximate hours number when operating under max performances and normal using
conditions
REPRESENTED BY:
M0202001a
VI-SERVICING THE MECHANICAL ASSEMBLY
REMARKS
• By measure of simplification, the described procedures don't mention the washers fitted with
fasteners (such as screws and nuts) and the magnet.
PRECAUTION
• Disconnect the electrical power Any accidental start-up must be prevented. position a notice at the
switch location to avoid start up.
• Check that there is no temperature before starting to operate
• Disconnect the hydraulic power
• Drains the oil from the housing (refer to chapter V-1 oil change)
REPRESENTED BY:
M00017001a 1 /1
VI-1 Assembly / Disassembly setting guide
Drawing 1066136400D00 rev00 M0203001
Disassembly Assembly
Perform the following steps before this Position Torque
disassembly :
[439] 80 N.m - 30 N.m
- disassembly of the adjusting stroke system
- disassembly of the wheel-connecting rod [435A] 40 N.m
assembly
1. Unscrew the screw [435A] 1. Fit the part [016A],[016] and insert the part [037A] in the
same time
2. Remove the part [008] 2. Insert the bearing [439B] on the part [068A]
3. Remove the assembly [016],[016A] from 3. Heat the internal cage of the bearing [439B] (110°C)
the upper side of the mechanical housing
4. Remove the part [068A] with the bearings 4. Insert the heated internal cage on the part [016]
[439B]
5. Remove the bearings [439B] 3. Fit the external cages of the bearing [439B] on the part
[068A]
REPRESENTED BY:
F F
E E
C (1 : 3)
016A
D D
016
435A
A
C C
A
B B B
PRIMEROYAL N
REGLAGE DE COURSE
A
A STROKE ADJUSTMENT
FORMAT Ech - Scale Folio - Page Matière - Material Numéro Plan Dwg-Nr
4 3 2 1 SOLIDWORKS
VI-2 Assembly / Disassembly of the wheel and
connecting rod
Drawing 1066136400D01 rev00 M0204001
Disassembly Assembly
Perform the following steps before this Position Torque
disassembly :
[435A] 40 N.m
- disassembly of the worm
[435E]-[435F] 280 N.m
2. Remove the part [037] 2. Position the connecting rod [014] on the part [016A]
3. Remove the parts[072A],[052] 3. Fit the part [068] equipped with the part [434B] to the
pump
7. Remove the parts [068] 7. Insert the assembly into the pump
8. Remove the connecting rod [014] 8. Fit the parts [037] to the pump
REPRESENTED BY:
F F
A A
E E
072A
037
435E D
D
438F
B (1 : 4) 435A
068
C 434B C
052
016A
B B
435F 014 A-A
29.09.04 EMISSION INITIALE YChevallier DDeparrois 00
Date Texte de la modification - Modification Dessiné-Drawned / Visa Vérifié-Checked / Visa Revision
PRIMEROYAL N
ROUE-BIELLE
A
A WHEEL-CONNECTING ROD
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
4 3 2 1 SOLIDWORKS
VI-3 Assembly / Disassembly of the worm
Drawing 1066136400D02 rev00 M0205001
Disassembly Assembly
Perform the following steps before this Position Torque
disassembly :
[439C] 80 Nm -30 Nm
disassembly of the motor
[435G] 20 Nm
[435F] 120 Nm
1. Unscrew the screws [435F] 1. Fit the external cages of the bearing [439F],[439G] to
the part[068D]
2. Remove the part [434C] 2. Heat the internal cage of the bearing [439G] (110°C)
3. Remove the part [068E] 3. Insert the internal cage of the bearing [439G] on the
worn [052]
4. Remove the seals [438I],[438G] 4. Insert the part [068D] on the worn [052]
5. Unscrew the screws [435G] 5. Insert the bearing cage [439F] on the worn [052]
6. Remove the worm [052] from the upper 6. Fit a new washer [439D]
7. Unscrew the nut [439C] 7. Tighten the nut [439C] in two time
10. Insert the worm [052] from the bottom of the housing
REPRESENTED BY:
F F
435F
438I
A (1 : 2)
E E
052 439E
068D 439G
D C (1 : 2) D
C C
B B
B (1 : 2)
30.09.04 EMISSION INITIALE YChevallier DDeparrois 00
Date Texte de la modification - Modification Dessiné-Drawned / Visa Vérifié-Checked / Visa Revision
PRIMEROYAL N
VIS SANS FIN
A
A WORM
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
4 3 2 1 SOLIDWORKS
VI-4 Assembly / Disassembly of the crosshead and spacer
Drawing 1066136410D00 rev00 M0227001
Disassembly Assembly
Perform the following steps before this Position Torque
disassembly :
[435B] 280 N.m
disassembly of the liquid-end assembly
[435A] 17N.m
1. Unscrew the screws [435B] 1. Protect the crosshead [010] with a cloth
2. Protect the crosshead [010] with a cloth 2. Position the crosshead [010] on the connecting rod
[014]
4. Remove the retaining ring [434] 4. Tighten the screws [435C] (mechanical stop)
8. Remove the part [068B] the lip of the seal [438C] must be positionned to
the internal side
REPRESENTED BY:
438A 438B
F 072C F
014
010
E 068B E
435C
B (1 : 3)
072B
A (1 : 3) 037B
D 434 D
438L
438C
438
C C
435B
B B
PRIMEROYAL N
COULISSEAU-LANTERNE A PISTON
A
A CROSSHEAD-SPACER
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
4 3 2 1 SOLIDWORKS
VI-5 Assembly/ Disassembly of the adjusting stroke system
Drawing 1066136400D04 rev00 M0207001
Disassembly Assembly
Position Torque
[435F] 120N.m
[435] 17N.m
[435A] 10N.m
1. Unscrew the screws[435A] 2. Position the part [072] on the side [A]
3. Remove the assembly [440],[055] 4. Insert the seal [438] on the part [056]
5. Unscrew the screws [435F} 6. Screw the screw [056] into the part [072] to obtain the
dimension X=30mm
11. Unscrew the locking screw [440A] 12. Exit the nut [008] to the maximum
13. Remove the part [056] 14. Fit the assembly to the pump (left-hand) and screw
of 9 turns
REPRESENTED BY:
008 081 438E 438A 435 056A 072 053 438B 440
F F
E 055
E
435A
438
Z
D 435B D
X
C C
B B
PRIMEROYAL N
REGLAGE MANUEL
A
A MANUAL STROKE ADJUSTMENT
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
4 3 2 1 SOLIDWORKS
VI-6.Assembly / Disassembly of the multiplexing
Drawing 1066136310 rev00 M0238001
Disassembly Assembly
Position Torque
[435] 60 N.m
1. Unscrew the screws [435B] 1. Fit the part [052] on the worm of the driving pump
3. Remove the part [440] to replace it 3. Fit the second part [052] to keep a clearance of 2mm
between both half coupling
4. If necessary unscrew the screws [435] to remove 4. Tighten the screw [435]
the parts [052]
REPRESENTED BY:
A (1 : 1)
A A
434A
072
B B
438A
C C
D D
E E
PRIMEROYAL N
ENS EQUIPEMENT MULTIPLEX
F 435B MULTIPLEX EQUIPMENT ASSEMBLY
F
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
Tel : +33 (0)2 32 68 30 00
A3 1:4 1/1 Fax : +33 (0)2 32 68 30 93 106.6136.310
Propriété exclusive - Communication et reproduction interdites. All rights reserved - Copyright DOSAPRO MILTON ROY COMPANY
1 2 3 6 7 8 SOLIDWORKS
VI-7.Assembly / Disassembly of the motor
Drawing 1066136200 rev 00 M0208001a
Disassembly Assembly
Position Torque
1. Unscrew the screws [435]. 1. Fit the part [052] to the worm (mechanical stop)
3. Remove the part [440] 3. Fit the part [072] to the pump
5. Remove the parts [052A] 5. Fit the part [052A] to the motor
REPRESENTED BY:
A A
A-A
072
B B
435A
052A
C C
434A
440
E
435B
D D
435 052
434
E E
27.12.04 Modif des vis de fixation + ajout repère 434A YChevallier DDeparrois 01
20/09/04 EMISSION INITIALE YChevallier DDeparrois 00
Date Texte de la modification - Modification Dessiné-Drawned / Visa Vérifié-Checked / Visa Révision
PRIMEROYAL N
ENS MONTAGE MOTEUR FF265
F FF265 MOTOR MOUNT ASSEMBLY
F
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
Tel : +33 (0)2 32 68 30 00
A3 1:2 1/ 1 Fax : +33 (0)2 32 68 30 93 1066.136.200
Propriété exclusive - Communication et reproduction interdites. All rights reserved - Copyright DOSAPRO MILTON ROY COMPANY
1 2 3 6 7 8 SOLIDWORKS
1
PART VII-SERVICING THE LIQUID END
VII-1 GENERAL
Remarks
By measure of simplification, the described procedures don't mention the washers fitted with fasteners
(such as screws and nuts).
Precaution
Special care has to be taken for chemicals used in the process (acids, bases, oxiding/reducing
solutions, ...).
Provide for the rinsing of the liquid end, if necessary, and provide for appropriate protective equipment
Check that there is no pressure and the temperature of components before starting to dismantle.
The plunger is connected to the crosshead of the mechanical assembly and has the same
reciprocating linear motion.
In the suction phase, the displacement of the plunger creates a negative pressure and allows the
suction of a given volume (swept volume) through the valve assembly , while valve assembly closes
the discharge circuit.
During the discharge phase, the process is reversed. The plunger expels the fluid from the process
through valve assembly, while valve assembly closes the suction circuit.
M0020001a
REPRESENTED BY: 1 /1
M8 M12
[435]
30 Nm 120 Nm
2. Unscrew the screws [435] 2. Insert the part [438A] into the liquid end [021]
3. Remove the assembly 3. Insert the spring [438AB] into the liquid end [021]
4. Remove the plunger [012] 4. Grease with “Loctite 8105” the parts [438C], [438D],
[438E], [438F], [438G], [438H],
5. Remove the parts [438F], [438E], [438D], 5. Insert the “V” seals [438D] into the liquid end [021]
[438C], [438B], [438A]
10. Insert the plunger [012] into the liquid end [021]
REPRESENTED BY:
A A
021
438
012
B B
009
435
D D
E E
438G 03.10.06 EMISSION INITIALE YChevallier DDeparrois 00
Date Texte de la modification - Modification Dessiné-Drawned / Visa Vérifié-Checked / Visa Révision
438H
ENS DOSEUR UTEX
F F
FORMAT Ech - Scale Folio - Page 27360 PONT-SAINT-PIERRE Numéro Plan Dwg-Nr
Tel : +33 (0)2 32 68 30 00
A3 1:4 2/ 2 Fax : +33 (0)2 32 68 30 93 106.6148.080.D00
Propriété exclusive - Communication et reproduction interdites. All rights reserved - Copyright DOSAPRO MILTON ROY COMPANY
1 2 3 6 7 8 SOLIDWORKS
B-B (1 : 1)
VII.4- Assembly / Disassembly of the single ball check valve
Drawing 1065696000 rev03 réf : M0054001a
Disassembly Assembly
Position Torque
flange nuts 70 Nm
1. Unscrew the three flange clamping screws 1. Fit a seal on each face of the seats [024].
and remove the connecting assemblies
2. Remove the seal [025], ball guide [003], ball 2. Position a seat [024] either on the liquid end
[437] and seat [024] equipped with two seals body or on the connecting assembly , taking
[025]. care to comply with the direction of fitting.
REPRESENTED BY:
The vendor guarantees his products according to the D.M.R. general conditions of sale.
The guarantee for components and sub-assemblies not fabricated by the vendor is limited
tothat given by the supplier.
The vendor’s guarantee only covers the replacement or the repair, at his cost and in his
factory, of all parts acknowledged by his technical services as being defective due to an error
in conception, of material or of execution.
It is the purchasers responsability to prove the said defects. The guarantee does not cover
the replacement of wear parts mentioned in part V - Preventive Maintenance.
The vendor reserves the right to modify all or part of his products in order to satisfy the
guarantee. The guarantee does not cover charges arising from dismantling, assembly,
transport and movements.
The replacement of one or several parts, for whatever reason, does not prolong the period of
guarantee.
The guarantee is not applicable notably in the following cases :
installation not in accordance with standard current practice.
deterioration or accident resulting from negligence.
lack of surveillance or maintenance.
modifications to conditions of use.
chemical corrosive or erosive attack. The proposed materials of construction are
recommendations subject in all cases to verification and acceptance by the client. The
recommendations, based on the experience of the vendor and the best available information,
do not guarantee against wear or chemical action.
INDUSTRIAL OWNERSHIP
This manual can only be used by the purchaser or the user. It cannot be distributed,
published, reproduced (partially or totally) or generally communicated to third parties without
the advance, formal written authorisation of the vendor.
Any breach of these rules may result in legel action being taken.
REPRESENTED BY:
M0014001a 1 /1
F FRANCE
ASSISTANCE TECHNIQUE : Tél. 33.(0.2.32.68.30.02 Fax . 33.(0)2.32.68.30.96
PIECES DE RECHANGE : Tél. 33 (0)2.32.68.30.01 Fax . 33.(0)2.32.68.30.92
ACCUEIL : Tél. 33.(0)2.32.68.30.00 Fax . 33.(0)2.32.68.30.93
10 Grande Rue 27360 Pont-Saint-Pierre ,France
www.dosapro.com email: contact@dosapro.com
E ESPAÑA
ASISTENCIA TECNICA Y PIEZAS DE REPUESTOS :
Tél. 34.91 517 80 00 - Fax. 34.91 517 52 38
C/Embajadores, 100 - 28012 MADRID
www.dosapro.es email: madrid@dosapro.es
I ITALIA
ASSISTENZA TECNICA E PARTI DI RICAMBIO :
Tel. 39.039 60.56.891 - Fax. 39.039 60.56.906
Centro Direzionale Colleoni - Via Paracelso 16
Palazzo Andromeda - Ingresso 1
20041 AGRATE BRIANZA (Ml)
www.miltonroy.it
GB UNITED KINGDOM
TECHNICAL ASSISTANCE AND SPARE PARTS :
Tel. 44.11.89.77 10 66 - Fax. 44.11.89 77 11 98 -
Oaklands Park, fishponds Road, WOKINGHAM - Berkshire RG 11 2FD
www.miltonroypumps.co.uk
OTHER COUNTRIES :
Representatives in all countries, contact in FRANCE:
INTERNATIONAL SALES DEPARTMENT
Tel. 33.2.32.68.3004 - Fax. 33.2.32.68.3094
www.dosapro.com email: contact@dosapro.com
06/01