Fire Alarm Systems | W‑HS Series Wall‑mount Multi‑candela Horn Strobes

W‑HS Series Wall‑mount Multi‑candela


Horn Strobes
▶ Sleek modern aesthetics
▶ Multiple voltages (12 VDC or 24 VDC)
▶ Voltage test points
▶ Eight strobe candela options and three horn volume
options
▶ Universal mounting base
▶ Environment‑friendly low current draw

The Cooper Wheelock Exceder Series Horn Strobes feature Certifications and Approvals
a sleek modern design that incorporates high reliability and
high-efficiency optics to minimize current draw. The
Region Certification
reduced current draw allows for a greater number of
USA UL ULSZ: Audible-signal Appliances (ANSI/UL
devices on the two‑wire notification appliance circuit. This,
464), UUKC: Signaling Appliances and
in combination with eight candela options in one appliance,
Equipment for the Hearing Impaired (ANSI/
no tools needed for changing settings, voltage test points, UL 1971)
12 V or 24 V DC operation, the universal mounting base, and
CSFM 7125-0785:168
multiple mounting options results in a reduced cost of
ownership. Canada ULC UEESC: Visual and Visual-audible Signal
Appliances, Fire Alarm (CAN/ULC-S525,
These horn strobes provide eight candela settings and three CAN/ULC-S541, CAN/ULC-S526, ULC-
sound settings on each appliance. All the switches to S527), ULSZC: Audible Signal Appliances
change these settings can be set without a tool and are and Accessories, Fire Alarm (CAN/ULC-
located behind the appliance to prevent tampering. S525, ULC-S527)
The separate universal mounting base can be easily
Cooper Wheelock has also designed these horn strobes to comply with:
mounted to five industry‑standard back box types. They can
US ADA ADAAG Equivalent Facilitation Guidelines
also be pre‑wired to allow full testing of the circuit wiring
before the appliance is installed and the surface finished. ANSI ANSI 117.1
These wall‑mounting horn strobes also feature voltage test FCC Tested and found to comply with the limits
points for taking readings with a volt meter for for a Class B digital device, pursuant to
Part 15 of the FCC Rules.
troubleshooting or AHJ inspection.
NEC National Electrical Code
NFPA NFPA 72

www.boschsecurity.com
2 | W‑HS Series Wall‑mount Multi‑candela Horn Strobes

Installation/Configuration Notes 3 For synchronization, use the SM or DSM modules with


Compatibility these control panels.
Horn: Mounting Considerations
The Universal Mounting Base supplied with each horn
These horns provide a selectable Continuous or Code 3
strobe can be pre-wired. With the supplied Contact Cover
horn tone when connected directly to the Fire Alarm
in place, the pre‑wired circuit can be checked for continuity
Control Panel (FACP). They can also provide a synchronized
before the horn strobes are mounted. The horn strobes
Code 3 Horn tone when used in conjunction with an FACP
snap onto the pre-installed Universal Mounting Bases with
that incorporates the Cooper Notification sync protocol, a
the Contact Covers removed and can be secured to the base
Cooper Notification Sync Module, or the Cooper
with an optional securing screw. The Universal Mounting
Notification Power Supply. The Horn Appliances can be field
Base flush mounts on single-gang, double-gang, 4 in.
set for High (HI), Medium (MED), or Low (LO) dBA sound
square, 4 in. octal, 3.5 in. octal, and 100 mm European-type
output.
back boxes.
Strobe:
Wiring Considerations
These strobes provide a non-synchronized strobe appliance
The wiring terminals on the Universal Mounting Base accept
when connected directly to a Fire Alarm Control Panel
two appliance wires with diameters between 12 AWG
(FACP), or provide a synchronized strobe appliance when
(2.3 mm) and 18 AWG (1.2 mm) at each terminal.
used in conjunction with an FACP that incorporates the
Cooper Notification sync protocol, a Cooper Notification
Sync Module, or the Cooper Notification Power Supply.
They are designed to flash at 1 flash per second minimum Parts Included
over their Regulated Voltage Range.
Quant. Component
Note Strobes are not designed to be used on coded 1 Horn Strobe appliance
systems in which the applied voltage is cycled 1 Universal mounting base
on and off.
1 Contact cover
Compatible Products 1 Hardware pack
The following Bosch Security Systems, Inc. products are • Two pan head mounting screws
compatible with the Cooper Wheelock Exceder Series
• One securing screw
1 Literature – Installation Instructions
Horn Strobes:

Category Product ID Product Description


Control Panels FPA-1000-UL1 Compact Fire Panel Technical Specifications
FPD-70241 Conventional or Addressable2 Audible Patterns and Ratings
FACP
Analog FACP Pattern Volume Sound Output1
D10024A3
Setting
D80243 Analog FACP
8.0 V 12.0 V 17.5 V
D91243 Addressable FACP
Continuous: High: 83 dBa 88 dBa 91 dBa
D70243 Conventional or Addressable2
Medium: 79 dBa 82 dBa 86 dBa
FACP
Low: 72 dBa 76 dBa 79 dBa
D70223 Conventional FACP
Code 32: High: 80 dBa 84 dBa 86 dBa
Modules SM‑12/24‑R Synchronization module (red)
Medium 74 dBa 78 dBa 82 dBa
DSM‑12/24‑R Dual synchronization module
(red) Low: 68 dBa 72 dBa 76 dBa
Power Supplies FPP-RNAC-8A-4C1 Remote Notification Appliance 16.0 V 24.0 V 30.0 V
Circuit (RNAC) Power Supply Continuous: High: 91 dBa 93 dBa 96 dBa
PS‑24‑8MC1 Power supply with built-in syn- Medium: 86 dBa 89 dBa 92 dBa
chronization protocol
Low: 78 dBa 82 dBa 85 dBa
1These products have built‑in Cooper Notification synch Code 32: High: 86 dBa 89 dBa 91 dBa
protocol.
Medium 81 dBa 85 dBa 84 dBa
2 When used with a D7039 Multiplex Expansion Module, the
Low: 74 dBa 78 dBa 80 dBa
FPD‑7024 or the D7024 becomes an addressable FACP.
W‑HS Series Wall‑mount Multi‑candela Horn Strobes | 3

1 Sound output is a minimum UL rating based on sound Horn and Strobe Current Draw5
power measurements at a distance of 10 ft (3 m) in a
FWR: High: 15 cd: 133 mA, 15/75 cd: 138 mA,
reverberant test room per UL464. 30 cd: 138 mA, 75 cd: 216 mA,
2The Code 3 temporal pattern (1/2 second on, 1/2 second 95 cd: 258 mA, 110 cd: 289 mA,
135 cd: 357 mA, 185 cd: 384 mA
off, 1/2 second on, 1/2 second off, 1/2 second on,
1-1/2 second off and repeat) is specified by ANSI and NFPA Medium: 15 cd: 112 mA, 15/75 cd: 126 mA,
30 cd: 126 mA, 75 cd: 201 mA,
72 for standard emergency evacuation signaling.
95 cd: 247 mA, 110 cd: 272 mA,
Note The Code 3 temporal pattern should be used 135 cd: 340 mA, 185 cd: 378 mA
only for fire evacuation signaling and not for Low: 15 cd: 106 mA, 15/75 cd: 120 mA,
any other purpose. 30 cd: 120 mA, 75 cd: 196 mA, 95 cd:
235 mA, 110 cd: 265 mA,
Environmental Considerations 135 cd: 331 mA, 185 cd: 375 mA
12 V nominal (8.0 V to 17.5 V range)
Environment: Indoor, dry
Voltage Volume Current Draw
Relative Humidity: 93±2% maximum, non‑condensing
Type Setting
Temperature (operating): +32°F to +120°F (0°C to +49°C)
DC: High: 15 cd: 125 mA, 15/75 cd: 159 mA
Mechanical Properties Medium: 15 cd: 122 mA, 15/75 cd: 153 mA

Candela Ratings3: 15 cd, 15/75 cd4, 30 cd, 75 cd, 95 cd, Low: 15 cd: 120 mA, 15/75 cd: 148 mA
110 cd, 135 cd, or 185 cd Voltage (input)
Dimensions: 5.24 in. x 4.58 in. x 2.19 in. Regulated Range
(133.1 mm x 116.4 mm x 55.7 mm)
12 VDC 8.0 V to 17.5 V
Material: Molded plastic enclosure incorporating a
24 VDC or Vrms 16.0 V to 33.0 V
Xenon flashtube and Lexan lens.
5Current Draw is the same for the Continuous Horn and
Volume Settings: 90 db, 95 db, or 99 db
Code 3 Horn Settings.
3When set for 12 V operation, strobe devices are only
Trademarks
approved by UL to be set at 15cd or 15/75 cd and only to
be powered by DC not FWR. Trademark names are used throughout this document. In
most cases, these designations are claimed as trademarks
4Although this product is UL Listed at 15 cd, it provides 75 or registered trademarks in one or more countries by their
cd on axis. respective owners. Rather than placing a trademark symbol
Power Requirements in every occurrence of a trademark name, Bosch Security
Systems, Inc. uses the names only in an editorial fashion
Horn and Strobe Current Draw5 and to the benefit of the trademark owner with no intention
24 V nominal (16.0 V to 33.0 V range) of infringing the trademark.
Voltage Volume Current Draw
Cooper Notification, Cooper Wheelock, Wheelock and Exceder are either
Type Setting
trademarks or registered trademarks of Cooper Wheelock, Inc. which is a
DC: High: 15 cd: 82 mA, 15/75 cd: 95 mA, division of Cooper Menvier, a Cooper Industries, Ltd. company.
30 cd: 102 mA, 75 cd: 148 mA,
Lexan is a registered trademark of General Electric Corporation, USA, in the
95 cd: 176 mA, 110 cd: 197 mA,
United States and other countries.
135 cd: 242 mA, 185 cd: 282 mA
Medium: 15 cd: 73 mA, 15/75 cd: 83 mA,
30 cd: 87 mA, 75 cd: 139 mA,
95 cd: 163 mA, 110 cd: 186 mA, Ordering Information
135 cd: 230 mA, 185 cd: 272 mA
W‑HSR Wall‑mount Multi‑candela Horn W-HSR
Low: 15 cd: 65 mA, 15/75 cd: 75 mA, Strobe (two‑wire, 12/24 V, red)
30 cd: 87 mA, 75 cd: 139 mA, Rectangular red two‑wire horn strobe field‑se-
95 cd: 157 mA, 110 cd: 184 mA, lectable for three volume options and eight
135 cd: 226 mA, 185 cd: 267 mA candela options.
W‑HSW Wall‑mount Multi‑candela Horn W-HSW
Strrobe (two‑wire, 12/24 V, white)
Rectangular white two‑wire horn strobe
field‑selectable for three volume options and
eight candela options.

www.boschsecurity.com
4 | W‑HS Series Wall‑mount Multi‑candela Horn Strobes

Americas: Europe, Middle East, Africa: Asia-Pacific: Represented by


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems
130 Perinton Parkway P.O. Box 80002 11 Bishan Street 21
Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943
Phone: +1 800 289 0096 Phone: + 31 40 2577 284 Phone: +65 6258 5511
Fax: +1 585 223 9180 Fax: +31 40 2577 330 Fax: +65 6571 2698
security.sales@us.bosch.com emea.securitysystems@bosch.com apr.securitysystems@bosch.com
www.boschsecurity.us www.boschsecurity.com www.boschsecurity.com

© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T6888480011 | Cur: en-US, V2, 4 Jul 2010

You might also like