QB300
QB300
QB300
DIRECT OPERATED PROPORTIONAL DIRECTIONAL AND FLOW VALVES - CLOSED LOOP update 11-18 This section considers the different valves options, illustrating the multiple variants of the available electrical connections.
The electrical connections have to be wired according to the selected valve code
Valve model:
DHZO-TEB DKZOR-TEB QVHZO-TEB STEP 1
DLHZO-TEB DLKZOR-TEB QVKZOR-TEB 1 Remove main connector cap P2 2 Select main connector according to valve code and
proceed with wirings operations
Driver model:
E-RI-TEB-N P2 A1 A2
STEP 3
STEP 4
IDENTIFICATION
Valve identification plates and label Valve name plate : N Driver label : L
www.atos.com
3 made in Italy
2 E-RI-TEB-N-NP-01H 10 4
DLHZO-TEB-SN-NP-040-T53/I B: USB
L 1 B 2 3 1: +5V_USB WARNING: remove power supply before any Recommended LiYCY Recommended LiYCY
0123456789
2: ID
3: GND_USB
STEP 2 shielded cables: shielded cable:
N DLHZO-TEB-SN-NP-040-T53/I A 1 1
5
4 4: D-
5: D+
electrical or wiring operations
F
B A: MAIN
E
G
A: V+ ext. fuse 2,5A 5 T-000
7 x 0,75 mm2 max 20 m 12 x 0,75 mm2 max 20 m
C B: V0 E: INPUT-
D
C: AGND F: Q_MONITOR 7 x 1 mm2 max 40 m
3
A D: Q_INPUT+ G: EARTH
0123456789
STEP 1 STEP 2 STEP 3 STEP 4 F Q_MONITOR (±10VDC / 4 ÷ 20mA) 6 Q_MONITOR (±10VDC / 4 ÷ 20mA)
A1 G EARTH 7 AGND
MECHANICAL ELECTRICAL HYDRAULICS SOFTWARE 8 R_ENABLE (ouput 24VDC)
STEP 1 MECHANICAL /Q option 9 NC
INSTALLATION TOOLS ACCORDING TO VALVE MODEL - not included A V+ (power supply 24VDC) 10 NC
In case of first commissioning, before the valve installation the whole system must be cor-
ZM-12P (metallic) B V0 (power supply 0VDC) 11 FAULT (output 24VDC)
Fastening bolts Wrenches Main connectors rectly flushed to grant the required cleanliness level
12 PIN MAIN CONNECTOR C ENABLE (input 24VDC) PE EARTH
During the flushing operation use on-off or by-pass valves in place of the proportional valve
std, /Q, /F /Z D Q_INPUT+
(±10VDC / 4 ÷ 20mA)
• remove protection pad P1 located on the valve bottom face only immediately before installation A2
E INPUT-
(do not remove connectors caps) F Q_MONITOR (±10VDC / 4 ÷ 20mA)
or
• check the presence and correct positioning of the seals on valve ports G EARTH
• verify that valve mounting surface is clean and free from damages or burrs /F option
socket head screws for fastening bolts and air bleeding 7 pin - metallic 12 pin - metallic P1 • verify the correct valve orientation according to the pattern of the relevant mounting interface NOTE: the use of above metallic connectors is strongly A V+ (power supply 24VDC)
see STEP 1 and STEP 3 see STEP 2 • lock the fastening bolts respecting below sequence and tightening torque according to valve model recommended in order to fulfill EMC requirements B V0 (power supply 0VDC)
C AGND
PROGRAMMING TOOLS - not included D Q_INPUT+
(±10VDC / 4 ÷ 20mA)
E INPUT-
Software USB connection KIT OR Bluetooth connection KIT DHZO-TEB / DLHZO-TEB DKZOR-TEB / DLKZOR-TEB WARNING: a safety fuse is required in series
F FAULT (output 24VDC)
Mounting surface layout Mounting surface layout to driver power supply - 2,5 A time lag fuse
Cable Isolator Cable Adapter G EARTH
n°1 OR 2025 for option /Y n°1 OR 108 for option /Y
4401-03-02-0-05
y
4401-05-04-0-05 P y
T
4401-03-03-0-05 4401-05-05-0-05 A B ELECTRICAL WIRING EXAMPLES
(for /Y without X port) A B (for /Y without X port) T T
E-SW-BASIC P n°4 OR 108
free basic software download at: Valve size ISO 4401: 06 Valve size ISO 4401: 10 n°5 OR 2050 MAIN CONNECTOR - VOLTAGE MAIN CONNECTOR - CURRENT
www.atos.com E-C-SB-USB/M12 E-A-SB-USB/OPT E-C-SB-M12/BTH E-A-SB-USB/BTH
REFERENCE INPUT - DIFFERENTIAL MODE REFERENCE INPUT - DIFFERENTIAL MODE
Fastening bolts Tightening torque: 8 Nm Fastening bolts Tightening torque: 15 Nm
main connector main connector
socket head screws socket head screws cabinet side pin-out valve internal circuit cabinet side pin-out valve internal circuit
4÷20 mA
0÷10 VDC std /F /Q /Z std /F /Q /Z Rsh = 500 ohm
DOWNLOAD AREA
Q_INPUT+ 50K Q_INPUT+
Ref. Q D 4 Ref. Q D 4
E-SW-BASIC free basic software can be download upon web registration at www.atos.com INPUT- 50K INPUT-
Upon web registration user receive via email the Activation Code (software free license) and login data to access Ref. Q E 5 Ref. Q E 5
STEP 3 HYDRAULICS
RELATED DOCUMENTATION - www.atos.com - section Catalog on-line
F003 Commissioning and troubleshooting - tech. table GS208 TEB/LEB basic drivers - tech. table V
Air bleeding - only DHZO, DLHZO, DKZOR and DLKZOR:
FS165 DHZO, DKZOR positive spool overlap - tech. table GS500 Programming tools - tech. table
V
• release 2 or 3 turns the air bleed screw V
FS168 DHZO, DKZOR zero spool overlap - tech. table K500 Electric / electronic connectors - tech. table • cycle the valve at low pressure until the oil leaking from the V port
is exempted from air bubbles
FS180 DLHZO, DLKZOR servoproportional - tech. table STARTUP-BASIC Software startup guide
• lock the air bleed screw V
FS412 QVHZO, QVKZOR flow controls - tech. table STARTUP-BTH Bluetooth adpter startup guide
P005 Mounting surfaces - tech. table E-MAN-RI-LEB TEB/LEB - driver operating manual Wrenches types
P007 Functional safety - tech. table Tightening NOTE: to facilitate bleeding operations, apply a light backpressure
DHZO torque (1 or 2 bar) by adding a check valve on T line for standard valves or
P010 O-Ring size - tech. table DLHZO
3 mm 4 Nm on Y line for valves with /Y option
CONTACT US Tightening
DKZOR or torque
Atos spa - Italy - 21018 Sesto Calende DLKZOR Consult tech table F003 for general guidelines about component’s
4 mm 13 mm 8 Nm commissioning
ü www.atos.com support@atos.com
STEP 4 SOFTWARE BIAS AND SCALE - 2 POSITION VALVES and FLOW CONTROL VALVES WIZARD REFERENCE - E-SW level 2 functionality
REMARK proportional valves with integral electronics are factory preset with default parameter and ready to use after piping Bias setting: supply input signal just over the Threshold value; increase the Bias until the actuator is start moving, then Reference input signal is factory preset according to selected valve code, defaults are ±10 VDC for standard and 4 ÷ 20 mA for /I option.
and electrical connections. Play with parameters is optional, not mandatory! lightly reduce the Bias just to stop the actuator Input signal can be reconfigured via software selecting between voltage and current, browsing to Reference Analog Range page:
Scale setting: supply the max input signal; adjust the Scale to obtain the max actuator speed
4.1 CONNECTION
2 Remove USB plastic protection cap P3 and connect valve to the PC as shown below
REMARK: Voltage Standard or Current 4..20 mA buttons do not act on Monitor output signal configuration!
B For Monitor output signal configuration browse to page Others - Monitor Outputs
E-C-SB-USB/M12 E-SW-BASIC
B
USB CABLE - cable lenght 4m installed on PC
P3
BIAS AND SCALE - 3 POSITION VALVES 4.3 STORE
E-A-SB-USB/OPT
isolator adapter Follow the same indications reported for 2 position valves for both valve’s solenoids Parameters modifications will be stored into driver permanent memory
WARNING: During valve parameters storing operations, the driver automatically shuts down the solenoid power
supply for a short time. Do not perform any storing commands while the system is working.
3
Launch the software using E-SW icon:
• software does NOT detect valid connection
communication is not established, please follow wizard procedure 4
• software detects valid connection
communication automatically established - valve is ON-LINE see 5
CONNECT TO
NP, PS, IR
OFFSET AND SCALE – 3 POSITION VALVES, ZERO OVERLAP
a b Offset setting: supply the input signal equal to 0%; adjust the Offset until the actuator is stopped
4.4 BACK UP
Scale setting: supply the max input signal (positive/negative); adjust the Scale to obtain the max actuator speed in both directions
Parameter modifications will be saved into PC memory
Single solenoid directional Double solenoid directional Single or double solenoid directional Ramps setting: select the required ramp configuration and adjust the ramp time to optimize the actuator’s acceleration and Valve vibration or noise
control valve, 2 positions control valve, 3 positions control valve, 3 positions deceleration • presence of air in the solenoid; perform air bleeding procedure – see STEP 3
with positive overlapping with positive overlapping with zero overlapping
and flow control valve No Ramp : no ramps selected Double Ramp : setup Ramp 1 and 2 The valve does not follow the reference signal
Single Ramp : setup Ramp 1 Four Ramps : setup Ramp 1, 2, 3 and 4 (only 3 way) • valve is powered off, verify presence of 24 Vdc power supply
• valve is disabled, verify presence of 24 Vdc on enable pin - only for /Q and /Z options
Spool position [%] Spool position [%] Spool position [%] • flow/pressure values exceeding the valve’s performance limits, verify that hydraulic operating conditions are incompliance
BiasP BiasP
Threshold with the valve's characteristics
BiasP BiasP • spool sticking, contact Atos service center
Threshold Offset
BiasN Software parameters modifications are lost when valve is switched off
ScaleP ScaleP ScaleP
• parameter store operation was not performed, check store procedure – see STEP 4, section 4.3
Reference [%] Reference [%] Reference [%]
ScaleN ScaleN Software parameters modifications have no effect on the valve
• valve is OFF LINE, check connection procedure – see STEP 4, section 4.1
BiasN
After the modifications of software parameters the valve does not work properly
• restore valve factory parameters using ‘Restore Factory’ button, located in ‘Driver - Memory Store’ window:
BiasP positive bias BiasP positive bias ScaleP positive scale - during restore, the current to the solenoid(s) will be temporarily switched to off!
ScaleP positive scale ScaleP positive scale ScaleN negative scale - factory parameters will be applied at next driver restart or after power off-on sequence!
BiasN negative bias Offset
ScaleN negative scale
Threshold = 2% Threshold = 2%
(200mV or 0,32mA for /I option) (±200mV or ±0,16mA for /I option)