Lite-On Technology Corp.: 6N137 - High Speed 10Mbd Optocouplers Description Features
Lite-On Technology Corp.: 6N137 - High Speed 10Mbd Optocouplers Description Features
Lite-On Technology Corp.: 6N137 - High Speed 10Mbd Optocouplers Description Features
DESCRIPTION FEATURES
These diode-transistor photocouplers * High speed – 10MBd
consist of an AlGaAs LED optically * Common mode rejection - 10KV/μs
coupled to a high speed photodetector. * UL, CSA, IEC/EN/DIN EN60747-5-2 –
The output features is an open collector Pending
and coupler parameters are guaranteed * Dual-in-line package- 6N137
over the temperature range from * Wide lead spacing package- 6N137M
-40℃~85℃. The internal shield * Surface mounting package- 6N137S
provides a guaranteed Common Mode * Tape and reel packaging-
Transient Immunity (typical) 10KV/μs 6N137S-TA/6N137S-TA1
APPLICATIONS
* High Voltage Isolation
* Line receivers
* Feedback Element in Switching Mode Power Supplies
* High Speed Logic Ground Isolation – TTL/TTL, TTL/CMOS, TTL/LSTTL
* Pulse transformer replacement
* Power transistor isolation in motor drives
* Microprocessor system interfaces
* Ground loop elimination
OUTLINE DIMENSIONS
6N137:
6N137M
OUTLINE DIMENSIONS
6N137S
TAPING DIMENSIONS
6N137S-TA
6N137S-TA1
Forward Current IF 25 mA
Power Dissipation P 40 mW
Output Voltage VO 7 V
OUTPUT
Output Current IO 50 mA
Power Dissipation PO 85 mW
Note
1. AC For 1 Minute, R.H. = 40 ~ 60%
Isolation voltage shall be measured using the following method.
(1) Short Pin 1 to Pin4 on the primary side and Pin 5 to Pin 8 on the secondary side.
(2) The isolation voltage tester with zero-cross circuit shall be used.
(3) The waveform of applied voltage shall be a sine wave.
2. For 10 sec.
Input
Output
IF=0mA, VE=0.5V
High Level Supply Current ICCH — 7 10 mA
VCC=5.5V
IF=10mA, VE=0.5V
Low Level Supply Current ICCL — 9 13 mA
VCC=5.5V
VCC=5.5V,
Low Level Enable Current IEL — -0.8 -1.6 mA
VE=0.5V
VCC=5.5V,
High Level Enable Current IEH — -0.6 -1.6 mA
VE=2.0V
25 30 75
Propagation Delay time to Logic Low RL =350Ω
tPHL ns
Output (1)→(0) CL = 15pF
100
25 40 75
Propagation Delay time to Logic High RL =350Ω
tPLH ns
Output (0)→(1) CL = 15pF
100
RL =350Ω
Pulse Width Distortion ∣tPHL- tPLH∣ 10 ns
CL = 15pF
RL =350Ω
Output Rise Time (10%~90%) tr 50 ns
CL = 15pF
RL =350Ω
Output Fall time (90%~10%) tf 12 ns
CL = 15pF
IF=7.5mA
Enable Propagation Delay Time at high VEH =3.5V
tELH 20 ns
level output(1) RL =350Ω
CL = 15pF
IF=7.5mA
Enable Propagation Delay Time at low VEH =3.5V
tEHL 20 ns
level output(0) RL =350Ω
CL = 15pF
IF=0mA
Instantaneous common mode rejection VOH(Min)=2.0V
|CMH| 1 10 — KV / μs |VCM|=50VP-P,
at high logic output (1)
RL=350Ω
IF=7.5mA
Instantaneous common mode rejection VOH(Max)=0.8V
|CML| 1 10 — KV / μs |VCM|=50VP-P,
at low logic output (0)
RL=350Ω
** All typical at TA = 25℃
BNS-OD-C131/A4
LITE-ON TECHNOLOGY CORP.
Property of Lite-on Only
ISOLATION CHARACTERISTICS
( TA = -40~85°C, VCC = 5V, IF =7.5mA unless otherwise specified)
TRANSFER CHARACTERISTICS(DC)
( TA = -40~85°C, VCC = 5V, IF =7.5mA unless otherwise specified)
VCC=5.5V,
Vo=0.5V
High Level Output Current IOH 100 uA
IF=250μA,
VE=2.0V
VCC=5.5V,
IF=5mA,
Low Level Output Voltage VOL 0.35 0.6 V
VE=2.0V
IOL=13mA
VCC=5.5V,
Vo=0.5V
Input Threshold Current IFTH 3 5 mA
IOL=13mA,
VE=2.0V
** All typical at Vcc=5V,TA = 25℃
Note:
1. AC For 1 Minute, R.H. = 40 ~ 60%
Isolation voltage shall be measured using the following method.
(1) Considered a two-terminal device: Pin 1,2,3,4 shorted together and Pin 5,6,7,8 shorted
together.
(2) The isolation voltage tester with zero-cross circuit shall be used.
(3) The waveform of applied voltage shall be a sine wave.
2. For 10 sec.
3. Pin5 and Pin8 must connect a bypass 0.1uF capacitor.
Notes:
- The products shown in this publication are designed for the general use in electronic
applications such as office automation equipment, communications devices, audio / visual
equipment, electrical application and instrumentation.
- For equipment/devices where high reliability or safety is required, such as space applications,
nuclear power control equipment, medical equipment, etc, please contact our sales
representatives.
- When requiring a device for any”specific” application, please contact our sales in advice.
- If there are any questions about the contents of this publication, please contact us at your
convenience.
- The contents described herein are subject to change without prior notice.