Design of C Section Purlin: From Table C Section (D, TW, Ix, ZX, Zy, SX, Sy)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Design of C section Purlin

𝑾𝑫 = 𝑫. 𝑳 ∗ 𝑺 + 𝑶. 𝑾 = ⋯ . 𝒍𝒃/𝒇𝒕

𝑶. 𝑾 = 𝟐𝟎 𝒍𝒃/𝒇𝒕 𝑺 = 𝟒~𝟔 𝒇𝒕

𝑾𝑳 = 𝑳. 𝑳 ∗ 𝑺 = ⋯ . 𝒍𝒃/𝒇𝒕 𝒘𝒉𝒆𝒓𝒆 𝑳. 𝑳 = 𝟐𝟎 𝑰𝒃/𝒇𝒕𝟐

𝑾𝒖 = 𝟏. 𝟐𝑾𝑫 + 𝟏. 𝟔𝑾𝑳
𝒊𝒏
∝= 𝒕𝒂𝒏−𝟏 (𝒔𝒍𝒐𝒑𝒆) [ ]
𝒇𝒕∗𝟏𝟐

𝑾𝒖𝒙 = 𝑾𝒖 𝒔𝒊𝒏 ∝ 𝑾𝒖𝒚 = 𝑾𝒖 𝒄𝒐𝒔 ∝

𝑾𝒖𝒚 𝑳𝟐
𝑴𝒖𝒙 =
𝟖
𝑾𝒖𝒙 𝑳𝟐
𝑴𝒖𝒚 = (𝒏𝒐 𝒕𝒊𝒆 𝒓𝒐𝒅 )
𝟖
𝑳 𝟐
𝑾𝒖𝒙 ( )
𝐌𝐮𝐲 = 𝟐 (𝐰𝐢𝐭𝐡 𝐨𝐧𝐞 𝐭𝐢𝐞 𝐫𝐨𝐝 )
𝟖
𝑴𝒖𝒙 + 𝟐 ∗ 𝟗 ∗ 𝑴𝒖𝒚
𝒁𝒙 ≥
𝟎. 𝟗 ∗ 𝒇𝒚

From table C section ( d , tw , Ix, Zx , Zy, Sx , Sy ).


𝑴𝒖𝒙 𝟐𝑴𝒖𝒚
+ ≤𝟏
∅𝐌𝐧𝐱 ∅𝑴𝒏𝒚
𝒁𝒚
∅𝑴𝒏𝒙 = 𝟎. 𝟗 𝑭𝒚 𝒁𝒙 ∅𝑴𝒏𝒚 = 𝟎. 𝟗 𝑭𝒚 𝒁𝒚 → ≤ 𝟏. 𝟔
𝑺𝒚

𝒁𝒚
∅𝑴𝒏𝒚 = 𝟎. 𝟗 ∗ 𝟏. 𝟔𝑭𝒚 𝑺𝒚 → > 𝟏. 𝟔
𝑺𝒚
𝑾𝒖𝒚 𝑳
𝑽𝒖𝒚 = ∅𝑽𝒏 = 𝟎. 𝟔 ∗ 𝑭𝒚 ∗ (𝒅 ∗ 𝒕𝒘)
𝟐
𝑽𝒖𝒚
≤𝟏
∅𝑽𝒏