Application Note Grounding Kit (#1993, #1995, #1996, #1997) Instructions
Application Note Grounding Kit (#1993, #1995, #1996, #1997) Instructions
Application Note Grounding Kit (#1993, #1995, #1996, #1997) Instructions
For many sites, the NRG grounding kit provides all the needed parts to earth ground your TallTower and instrumentation.
The grounding kit includes a copper-clad lightning spike, copper ground wire, and two copper-clad ground rods. Determine
the soil type and classify its resistivity. The lower the resistivity, the better the earth ground.
The NRG grounding kit will perform adequately in type 1 and 2 soils. For other soil types, or for sites with a high incidence
of lightning, you will need to augment the earth grounding system. Consult NRG for more information.
Installation
The grounding kit is usually installed before the sensors and sensor cabling in a new installation, but may also be retro-
fitted to an existing tower installation. Refer to the drawing on the next page. To install the grounding kit:
1. Drive the two ground rods through the holes provided in the TallTower baseplate when laying out the tower. Leave
enough of each rods above the baseplate to attach the ground wires.
2. Raise the TallTower slightly off the ground. Attach the top end of the copper ground wire to the lightning spike using
one of the supplied ground clamps. Mount the lightning spike to the tower using the two supplied stainless steel band
clamps.
3. Unwind the ground wire to the base of the tower, wrapping the wire around the tower in a downward spiral, 1 turn every
6 meters (20 feet) as shown in the figure. Tape the wire securely to the tower every 1 to 2 meters (3 to 6 feet) to
prevent the wire being damaged by wind motion or icing.
4. For best protection, mount all sensors below a 45 cone from the lightning spike, as shown in the drawing on the next
page. Sensors on top-mount or Z booms may be at the top of the tower. For sensors on side-mount booms, keep the
boom at least 0.6 m (2 feet) below the top of the tower.
5. Attach the bottom end of the ground wire to BOTH ground rods using the supplied clamps. This is easiest if the first
clamp is threaded over the end of the ground wire before leading the wire to the second clamp.
6. Ground your NRG logger. Connect the logger grounding cable supplied with the logger from the ground stud or
terminal on the logger to one of the ground rods, using the same ground clamp as for the tower
ground. Ground the logger immediately after mounting it to the TallTower and prior to connecting
the sensors to the logger.
Global leader in wind measurement technology
110 Riggs Road · Hinesburg · VT 05461 USA · TEL (802) 482-2255 · FAX (802) 482-2272 · EMAIL sales@nrgsystems.com
angroundkit.doc Rev #5 5 January 2012
APPLICATION NOTE