Application Operation
Series D1V hydraulic directional control valves are Series D1V directional control valves consist of a
A high performance, direct operated 4-way valves.
They are available in 2 or 3-position styles. They are
4-chamber style body, and a case hardened sliding
spool. The spool is directly shifted by a variety of
manifold mounted valves, which conform to NFPA’s operators including: solenoid, lever, cam, air or oil
D03, CETOP 3 mounting pattern. These valves pilots.
were designed for industrial and mobile hydraulic
applications which require high cycle rates, long life
and high efficiency.
D1.indd, dd
Electrical Connections
Series D1V valves may be configured in all popular electrical configurations including:
D1.indd, dd
D1.indd, dd
D1.indd, dd
A
Maximum Flow, LPM (GPM)
350 Bar (5000 PSI) w/o Malfunction
High Watt Low Watt Low Watt
Model Spool Symbol DC AC DC
A B
D1V*001 78 (20) 49 (13) 37 (10)
P T
A B
D1V*002 78 (20) 45 (12) 68 (18)
P T
A B
D1V*003 70 (18) 30 (8) 34 (9)
P T
A B
D1V*004 37 (10) 30 (8) 68 (18)
P T
A B
D1V*005 60 (16) 45 (12) 45 (12)
P T
A B
D1V*006 79 (21) 49 (13) 52 (14)
P T
A B
D1V*007 45 (12) 18 (5) 18 (5)
P T
A B
D1V*008 49 (13) 45 (12) 37 (10)
P T
A B
D1V*009 58 (15) 45 (12) 45 (12)
P T
A B
D1V*010 13 (4) 11 (3) 15 (4)
P T
A B
D1V*011 58 (16) 30 (8) 37 (10)
P T
A B
D1V*014 45 (12) 18 (5) 18 (5)
P T
A B
D1V*015 79 (21) 30 (8) 34 (9)
P T
A B
D1V*016 60 (16) 45 (12) 52 (14)
P T
A B
D1V*020 78 (20) 45 (12) 75 (20)
P T
A B
D1.indd, dd
A
Maximum Flow, LPM (GPM) Maximum Flow, LPM (GPM)
350 Bar (5000 PSI) 350 Bar (5000 PSI)
Model Spool Symbol w/o Malfunction Model Spool Symbol w/o Malfunction
A B A B
D1V*1 83 (22) D1V*20 # 53 (14)
P T P T
A B A B
D1V*2 83 (22) D1V*26 # 11 (3)
P T P T
A B A B
D1V*4 45 (12) D1V*30 # 19 (5)
P T P T
A B A B
D1V*8 45 (12) D1V*81 30 (8)
P T P T
A B A B
Quantity Required
A,C,D B,E,F H,K,M
Hirschmann – Female Connector
692915 Gray (Solenoid A) 1 – 1
692914 Black (Solenoid B) 1 1 –
D1.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#004 spool) at 138 Bar (2000 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “004”. At 138 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(2000 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
57 LPM (15 GPM). At 207 Bar (3000 PSI), the flow 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
is 49 LPM (13 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#008 spool) at 83 Bar (1200 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “008”. At 83 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(1200 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
57 LPM (15 GPM). At 207 Bar (3000 PSI), the flow is 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
19 LPM (5 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#081 spool) at 83 Bar (1200 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “081”. At 83 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(1200 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
42 LPM (11 GPM). At 138 Bar (2000 PSI), the flow is 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
42 LPM (11 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
A
PSI Bar
5000 345
003,004,
011,015
009
300
4000
021,022
Supply Pressure
100 005,016,020
1000
50
0
L/M 10 20 30 40 50 60 70 80 83
0
GPM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Flow
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#009 spool) at 83 Bar (1200 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “009”. At 83 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(1200 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
75 LPM (20 GPM). At 207 Bar (3000 PSI), the flow is 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
68 LPM (18 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
Pressure Drop vs. Flow, D1VW Pressure Drop Reference Chart – 30 Watt Coil
High Watt
A
Curve Number
The table to the right provides Spool Shifted Center Condition
the flow vs. pressure drop No. P–A P–B B–T A–T (P–T) (B–A) (A–B) (P-A) (P-B) (A-T) (B-T)
curve reference for standard 001 3 3 2 2 — — — — — — —
and high performance D1V 002 2 2 1 1 2 1 1 1 1 1 1
Series valves by spool type. 003 2 2 1 1 — — — — — 1 —
The chart below demonstrates 004 2 2 1 1 — — — — — 2 2
graphically the pressure drop 005 2 3 1 1 — — — 5 — — —
characteristics of the standard 006 2 2 1 1 — 6 6 6 6 — —
D1VW*****F and the high 007 2 3 1 1 4 — 1 — — — —
performance D1V. The low watt 008 5 5 5 5 5 — — — — — —
coil and other design features 009 4 4 4 4 4 — — — — — —
of the standard D1VW*****F 010 3 3 — — — — — — — — —
accommodate a maximum flow 011 3 3 1 1 — — — — — 8 8
of 50 LPM (13 GPM) at
014 3 2 1 1 4 1 — — — — —
345 Bar (5000 PSI).
015 2 2 1 1 — — — — — — 1
016 3 2 1 1 — — — — 5 — —
020 4 4 2 2 — — — — — — —
026 4 4 — — — — — — — — —
030 2 2 1 1 — — — — — — —
081 7 7 8 8 — — — — — — —
082 7 7 8 8 — — — — — — —
D1.indd, dd
Pressure Drop vs. Flow, D1VW Pressure Drop Reference Chart – 10 Watt Coil
Low Watt Curve Number
D1.indd, dd
D1.indd, dd
General Description
Series D1VW directional control valves are high
performance, 4-chamber, direct operated, wet
armature solenoid controlled, 3 or 4-way valves.
B AB A A
They are available in 2 or 3-position and conform to
NFPA’s D03, CETOP 3 mounting patterns. PT
Features
• Soft shift available.
• 19 standard spool styles available (for other spools –
Consult Factory).
• Proportional spools.
• DC surge suppression.
• Eight electrical connection options.
• AC & DC lights available (CSA approval for solenoids and
lights).
• Internally ground.
• Easy access mounting bolts.
• Waterproof (meets NEMA 4, up to IP67 on some models). • U.L. recognized available - Contact the division.
• Explosion proof. • No tools required for coil removal.
• CSA approvals. • AC rectified coils.
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6 Leakage Rates* Maximum Allowable:
Mounting DIN 24340-A6 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/Land @
Interface ISO 4401-AB-03-4-A 49°C (120°F) 69 Bar (1000 PSI)*
CETOP R35H 4.2-4-03, 73.8 cc (4.5 Cu. in.) per Minute/Land @
NFPA D03 207 Bar (3000 PSI)*
Maximum P, A, B *#008 and #009 Typical:
Pressure 345 Bar (5000 PSI) Standard Spools may 4.9 cc (0.3 Cu. in.) per Minute/Land @
207 Bar (3000 PSI) 10 Watt exceed these rates. 69 Bar (1000 PSI)*
CSA 276 Bar (3750 PSI) Consult Factory 26.2 cc (1.6 Cu. in.) per Minute/Land @
Tank: 345 Bar (5000 PSI)
103 Bar (1500 PSI) AC only
207 Bar (3000 PSI) DC/AC
Rectified Standard Response Time
207 Bar (3000 PSI) AC Optional Response time (milliseconds) at 345 Bar (5000 PSI) is
CSA 103 Bar (1500 PSI) 32 LPM (8.5 GPM).
Solenoid Type Pull-In Drop-Out
AC 13 20
DC 10 Watt 61 22
DC 30 Watt 51 21
Spool Center Condition
Orifice Closed Open 2-Position
Soft Shift Size Energize De-Energize Energize De-Energize Energize De-Energize
S2 0.020 125 ms 920 ms 200 ms 275 ms 51 ms 100 ms
S5 0.050 51 ms 675 ms 50 ms 27 ms 51 ms 21 ms
D1.indd, dd
D 1V
NFPA D03 Code Description Code Description Code Description Code Description
CETOP 3 W* Solenoid, N Nitrile A** 24/50 VAC Q** 100/60 VAC
DIN NG6 Wet Pin, V Fluorocarbon D 120 VDC QD† 100/60 - 100/50 VAC
Screw-in
E* EPR G 198 VDC R 24/60 VAC
HW* Reversed
* Contact HVD for J 24 VDC T 240/60 - 220/50 VAC
Wiring
availability. K 12 VDC U 98 VDC
* Valve schematic symbols are per NFPA/
L 6 VDC Y 120/60 - 110/50 VAC
ANSI standards, providing flow P to A when
energizing solenoid A. Note operators reverse N*** 220/50 VAC Z 250 VDC
sides for #008 and #009 spools. See installation P*** 110/50 VAC
information for details. To configure per DIN ** High Watt only
standards (A coil over A port, B coil over B port) *** Explosion Proof only.
code valves as D1VHW***. † Available in DIN only.
010 082
* 020, 026 and 030 spools only.
P T P T † 020 and 030 spools only.
* 008, 020 & 026 spools have closed crossover. ‡ High Watt only.
** 009 & 030 spools have open crossover.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
87.8
(3.46)
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
D1.indd, dd
t
Note: A
u
163.7 2 black wires
(6.44) 18 Inch Lead 1 green wire
O
60.4
(2.38) Wires Standard
e
1/2" NPT
a s
94.4
(3.72)
130.8
(5.15)
P h 304.4
(11.98)
Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve.
46.0
(1.81)
73.0 (2.87)
15.1 (0.61)
7.5 (0.30)
113.0
(4.45)
131.7
(5.19)
100.9
(3.97) 100.6
(3.96)
42.8
(1.69)
7.5 (0.30)
141.0 (5.55)
46.0 (1.81)
73.5 (2.89) 324.7 (12.78)
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Monitor Switch
(Variation I7 and I8)
This feature provides for electrical confirmation of
the spool shift. This can be used in safety circuits,
to assure proper sequencing, etc.
Switch Data
Inductive switch requiring +18-42 volt input.
Outputs “A” and “B” are opposite; one at “0”
voltage, the other at input voltage. During
switching, “A” and “B” outputs reverse. Provides
0.4A switching current.
For repetitive switch power-up conditions, please consult factory.
D1.indd, dd
Manaplug (Options 56 & 1C) Micro Connector Options (7B & 1D)
Interface – Brad Harrison Plug
– 3-Pin for Single Solenoid
– 5-Pin for Double Solenoid
A
Ground
Wire #1 (Green)
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
A Bolt Kits for use with D1V Directional Control Valves, "ET" Explosion Proof & Sandwich Valves
(D1V*-91, 82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated)
Number of Sandwich Valves @40mm (1.58") thickness
0 1 2 3 4
BK209 1.25 in. BK243 2.88 in. BK225 4.38 in. BK244 6.00 in. BK245 7.50 in.
0
BKM209 30 mm BKM243 70 mm BKM225 110 mm BKM244 150 mm BKM245 190 mm
Number of Sandwich Valves at
BK246 3.00 in. BK247 4.62 in. BK248 6.12 in. BK249 7.75 in.
44.5mm (1.75") Thickness
1
BKM246 75 mm BKM247 115 mm BKM248 155 mm BKM249 195 mm
BK250 4.75 in. BK251 6.38 in. BK252 7.88 in.
2
BKM250 120 mm BKM251 160 mm BKM252 200 mm
BK253 6.50 in. BK254 8.12 in.
3
BKM102 170 mm BKM254 205 mm
BK103 8.25 in.
4
BKM103 210 mm
Note: All bolts are SAE Grade 8, 10-24 UNC 2A thread (Metric-M5-0.8)
Torque to 5.6 Nm (50 in-Lb).
Bolt Kits for use with D1V Directional Control Valves with Explosion Proof Coils & Sandwich Valves
(D1V*-91, 82 & 70/75 Design) Except "ET" Coil
Number of Sandwich Valves @40mm (1.58") thickness
0 1 2 3 4
BK50 2.00 in. BK211 3.63 in. BK101 5.12 in. BK102 6.75 in. BK103 8.25 in.
0
BKM50 50 mm — BKM101 130 mm BKM102 170 mm BKM103 210 mm
Number of Sandwich Valves at
BK51 3.75 in. BK212 5.37 in. BK105 6.87 in. BK106 7.75 in.
44.5mm (1.75") Thickness
1
BKM51 95 mm — BKM105 180 mm BKM106 195 mm
BK52 5.50 in. BK213 7.13 in. BK108 8.62 in.
2
BKM52 140 mm — BKM108 220 mm
BK53 7.25 in. BK214 8.87 in.
3
BKM53 185 mm —
BK54 9.00 in.
4
BKM54 230 mm
Note: All bolts are SAE Grade 8, 10-24 UNC 2A thread (Metric-M5-0.8)
Torque to 5.6 Nm (50 in-Lb).
D1.indd, dd
General Description
Series D1VA and D1VP directional control valves are B AB A
high performance, 4 and 5-chamber, direct operated,
air and oil pilot controlled, 3 or 4-way valves. They are P T
A
available in 2 or 3-position and conform to NFPA’s
D03, CETOP 3 mounting patterns. B AB A
Features P T
• Low pilot pressure required.
D1VA – 4.1 Bar (60 PSI) minimum
D1VP – 15.2 Bar (220 PSI) minimum
Air Operated
Shift Volume. The air pilot chamber requires a volume
of 1.8 cc (.106 in.3) for complete shift from center to
end.
Pilot Piston. The pilot piston area is 506 mm2 (.785
in.2). Pilot piston stroke is 3.4 mm (.135 in.).
Response Time. Response time will vary with pilot
line size, pilot line length, pilot pressure, air control
valve shift time and air valve flow capacity (Cv). Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Oil Operated Operating: 345 Bar (5000 PSI)
Maximum
Shift Volume. The hydraulic pilot chamber requires Pressure Tank Line: D1VA 34 Bar (500 PSI)
a volume of 0.7 cc (.042 in.3) for complete shift from D1VP 207 Bar (3000 PSI)
center to end. Maximum Flow See Reference Data
Pilot Piston. The hydraulic piston area is 198 mm2 D1VA:
Air Minimum 4.1 Bar (60 PSI)
(.307 in.2). Pilot piston stroke is 3.4 mm (.135 in.).
Pilot Pressure Air Maximum 10.2 Bar (150 PSI)
Response Time. Response time will vary with pilot D1VP:
line size, pilot line length, pilot pressure, pilot valve Oil Minimum 15.2 Bar (220 PSI)
shift time and oil valve flow capacity (GPM). Oil Maximum 207 Bar (3000 PSI)
23.0
Y
(0.91)
15.5 9.0
42.0 1/4 BSPP (90) (0.35)
(1.65) (0.61) 43.0 22.0
or (1.70) (0.87)
16.9
min.
(0.67)
SAE #4
Note: 22.0 mm (0.87”) from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
D 1V P
A Directional
Control
Valve
Basic
Valve
Actuator Spool Style Seal Variations Design
Series
NOTE:
Not required
when ordering.
Code Description
Code Symbol N Nitrile
A B V Fluorocarbon
001
P T
A B
002
Code
Description Symbol
P T
A B Single operator, two position
004 B# spring offset.
P to A and B to T in offset position.
P T
A B Double operator,
008* C three position,
P T
spring centered.
A B
D Double operator,
009**
two position, detent.
P T
A B Two position, spring centered.
020* E# P to B and A to T
P T in shifted position.
A B Single operator, two position,
026* H# spring offset. P to B and A to T
P T in offset position.
A B Two position, spring centered.
030** K# P to A and B to T
P T in shifted position.
A B
# D available with 020 and 030 spools only.
081 B & H available with 020, 026 and 030 spools only.
P T E & K not available with 020, 026 and 030 spools.
A B
D 1V A
Directional
Control
Valve
Basic
Valve
Actuator Spool Style Seal Variations Design
Series
NOTE:
A
Not required
when ordering.
Code Symbol
Code Description
A B
001 N Nitrile
V Fluorocarbon
P T
A B
002
P T Code
Description Symbol
A B
Single operator, two position b A B
004 B spring offset.
P T P to A and B to T in offset position. P T
A B
Double operator, b A B a
008* C three position,
P T spring centered. P T
A B
b A B a
009** D Double operator,
two position, detent.
P T
P T
A B
b A B
Two position, spring centered.
081
E P to B and A to T
P T in shifted position. P T
A B A B a
Single operator, two position,
082
H spring offset. P to B and A to T
P T in offset position. P T
A B a
* 008 spool has closed Two position, spring centered.
crossover. K P to A and B to T
** 009 spool has open in shifted position. P T
crossover.
Valve schematic symbols are per NFPA/
ANSI standards, providing flow P to A when
energizing operator A. Note operators reverse
sides for #008 and #009 spools. See installation This condition varies
information for details. with spool code.
117.8 (4.64)
61.6
104.55 (4.12)
(2.43)
38.5
192.5 (1.52)
(7.58)
51.95
(2.05)
23.8
(0.94)
23.0 (0.91)
46.0
Note: 22.0 mm (0.87") from bottom of bolt (1.81)
hole counterbore to bottom of valve.
D1.indd, dd
General Description
Series D1VC, D1VD and D1VG directional control
valves are high performance, 4-chamber, direct
operated, cam controlled, 4-way valves. They are
A
available in 2-position and conform to NFPA’s D03,
CETOP 3 mounting patterns.
Features
• Choice of 2 cam roller positions (D1VC and D1VD)
• Two styles available (D1VC and D1VG)
• Short stroke option
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Nominal Flow 32 LPM (8.5 GPM)
Maximum Flow See Reference Data
Force Required D1VC, D1VD: 107 N (24 lbs.)
to Shift D1VG: 36 N (8 lbs.)
Maximum
Cam Angle 30°
Ordering Information
D 1V
Directional Basic Actuator Spool Style Seal Variations Design
Control Valve Series
Valve NOTE:
Not required
NFPA D03 Code Symbol Code Description when ordering.
CETOP 3 A B N Nitrile
001 V Fluorocarbon
P T
A B
Code Description
002
P T
Omit Standard
A B P05 Short Stroke
004 P10* Monitor Switch
Code Description
P T * Not CE or CSA approved.
C Cam (90° to A B
mounting surface)
008* Code Description Symbol
D Cam parallel to
mounting surface
P T
Two position, A B
G Cam Lever
A B B spring offset operator
009† at “A” port end. P T
P T Two position, A B
A B H spring offset operator
081 at “B” port end. P T
Valve Weight: Type C & D 1.44 kg (3.2 lbs.) P T
Type G 1.6 kg (3.7 lbs.) Valve schematic symbols are per NFPA/
A B
Standard Bolt Kit: BK209 1–24x1.25 ANSI standards, providing flow P to A when
082
energized. Note flow paths reverse sides for
Metric Bolt Kit: BKM209 M5–0.8x30mm P T #008 and #009 spools.
Seal Kit:
* 008 spool has closed crossover.
Nitrile SKD1VC
† 009 spool has open crossover.
Fluorocarbon SKD1VCV
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
D1.indd, dd
38.5 38.4
Over-Travel (1.51)
(1.52) Full Spool Travel
Pre-Travel
Over-Travel
Full Spool Travel
Pre-Travel 38.5
(1.52)
38.5
(1.52)
79.1
(3.11)
52.0
(2.05)
See 23.8
Note (0.94)
General Description
Series D1VL directional control valves are high-
performance, 4-chamber, direct operated, lever
controlled, 4-way valves. They are available in 2 or
A B A
3-position and conform to NFPA’s D03, CETOP 3
mounting patterns. P T
Features
• Spring return or detent styles available
• Heavy duty handle design
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Reference Data
Force Required
to Shift Lever 25 N (5.6 lbs)
Operator
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
15.5
8.9° (0.61)
85.5 Full Shift
(3.37) 15.5
(0.61)
150.6
38.6 (5.93)
(1.52)
50.0
46.0 (1.97)
(1.81) 23.8
See
Note (0.94)
149.5 23.0
(5.89) (0.91)
46.0
(1.81)
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
D 1V
A Directional
Control
Valve
Basic
Valve
Operator
Type and Location
Spool Style Seal Variations Design
Series
NOTE:
Not required
when ordering.
D1.indd, dd
A 51.00
(2.000) M5-0.8 (10-24) UNC-2B thread
min. x 10.40 (.410) min. thread depth
40.50
(1.594) 4-holes
0.28
33.00
(0.011) S A B
(1.300)
30.20
5.10 (1.190)
(0.200)
21.50
(0.850)
0.75
(0.030) B
O 7.5 (.295) max.
A P.A.B. & T ports
T 0.56
15.50 (0.022)
L A B
31.00 (0.610)
43.00 (1.220)
(1.70) A
min.
25.90
(1.020) O 3.86/4.27 (.152/.168)
31.75 B x 4.00 (.160) min. depth
(1.250)
0.28
(0.011) S A B
P
12.70
(0.500)
4.80 (0.190) R. max. typ.
4 places
D1.indd, dd