Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 54

Load-sensing control block in mono block/sandwich plate design

M4-12
RE 64276
Edition: 04.2016
Replaces: 05.2015

▶▶ Size 12
▶▶ Series 2X
▶▶ Nominal pressure
–– on pump side 400 bar
–– on consumer side 420 bar
▶▶ Maximum flow
–– on pump side 300 l/min
–– 130 l/min on the consumer side with pressure
compensator and load holding function

Features Contents
▶▶ Flow control independent of load pressure Functional description 2
–– Open center for fixed pump Technical Data 3
–– Closed center for variable pump Modular system 5
▶▶ Sandwich plate design with up to 20 directional valves Ordering code 8
▶▶ Mono block with 1 axis, expandable with max. 9 directional Order examples 13
valves Inlet plates 17
▶▶ Type of actuation: mechanical, hydraulic, electrohydraulic Mono block 20
(switching, proportional or with on-board electronics) Directional valves 21
▶▶ Pressure limitation Types of actuation 28
–– Inlet plate: pilot operated pressure valves of large Secondary valves 31
nominal width Options 32
–– Directional valve/consumer ports: compact shock Available housing variants 33
valves with feed function End plates 34
▶▶ LS pressure limitation Dimensions 36
–– Adjustable per consumer port On-board electronics: Electronic pilot module (EPM) 49
–– External pressure setting per consumer port possible Accessories 51
–– Electro-proportional per section M4 configurator 53
Related documents 54
Fields of application
▶▶ Truck applications ▶▶ Construction machines
▶▶ Drilling equipment ▶▶ Aerial work platforms
▶▶ Forestry machinery ▶▶ Heavy duty vehicles
▶▶ High-capacity forklifts ▶▶ Marine engineering
and teleforklifts ▶▶ Mining applications
▶▶ Municipal vehicles ▶▶ Stationary applications
▶▶ Cranes

 RE 64276/04.2016, Bosch Rexroth AG


2 M4-12 | Control block
Functional description

Functional description

Control block M4-12 Load pressure compensation


The directional valves are proportional valves according to The pressure compensator (3) regulates pressure changes
the load sensing principle. on the consumers or on the pump. The flow to the consum-
ers remains constant, including with varying loads.
Consumer control
The main spool (2) is used to determine the flow direction Flow limitation
and the flow level that reaches the consumer ports (A or B). The maximum flow can be individually set mechanically at
Pressure reducing valves (10) control the position of the the factory according to the ordering code using the stroke
main spool (2). The size of the electric current on the limitations (7).
pressure reducing valve determines the level of the pilot
pressure in the spring chambers (9) and thereby the stroke Pressure limitation
of the main spool (P → A; P → B). The LS pressure for each consumer port can optionally be
The pressure compensator (3) keeps the pressure differential overridden internally via the LS pressure relief valves (4),
on the main spool (2) and thereby the flow to the consumers electro-proportionally for each spool axis or externally via
constant. the LS ports MA, MB.
Shock valves with large nominal widths with combined feed
function (5) protect consumer ports A and B against pres-
sure peaks.
The highest load pressure on the pump is reported via the
LS line and the integrated shuttle valve (8).

▼▼ Section M4-12 ▼▼ Symbol M4-12

4 2 7 6 5
P X Y LS T

B
9 5 6
12
A B
MA
„b“ MB
A
10 7 A B
T T 7 b
„a“ X
Y a P T
P
LSP

13 4 MA MB 8 1 3 2 11 9 14

8 10 3

1 Housing 5 Shock valve with 8 LS shuttle valve 12 Hand lever


2 Main spool feed function 9 Spring chamber 13 Cover A side
3 Pressure compensator 6 Threaded plug 10 Pressure reducing valve 14 Control B side
4 LS pressure relief valve 7 Stroke limiter 11 Compression spring

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 3
 Technical Data

Technical Data

General
Weight Inlet plate P SP J SJ JZ JK
kg 6 11.4 4.3 11 8.4 11
Mono block PM JM
kg 5.6 3.8
Directional valve M H W CBA
kg 4.9 4.2 4.5 4.8
Hand lever surplus weight kg 0.6
End plate LA LAPT LA… LA… … LZ LZPT
kg 3 4.3 3.8 3.8 2.8 4.4
LU LU… L8 TI
kg 3.5 4 4.5 6.3
Installation position Ideally horizontal to the spool axis.
For versions with spool position sensor, horizontal to
the spool axis or vertical, with the sensor cable on the
bottom.
Consumer line connections Pipe thread as per ISO 228/1 (inches),
ISO 11926-1 (UNF) or JIS B 2351-1 (on request)
Ambient temperature range θ °C -20 to 80 (−40° to +100°C on request)
Priming (standard) One-coat paint RAL 5010 (more on request)
Surface protection according to Standard priming h 96
DIN EN 60068-2-11 Special painting h 480
Painting for SO-038 h 1000

Mechanical
Actuating force on Mechanically operated N < 20
the hand lever Mechanical override (with parallel N < 70
(encapsulated) hydraulic actuation)
Mechanical override (with parallel N < 50
electrohydraulic actuation)
Actuating force in Tongue N < 250
spool axis Detent with tongue N < 350
(not encapsulated)

Hydraulic
Maximum working pressure at port P pmax bar 400 (420 on request)
A, B pmax bar 420
LS pmax bar 350
T pmax bar 30 (20 with mechanical actuation only)
Y pmax bar Must be routed to reservoir without pressure
Maximum pilot pressure at port a, b pSt bar 35
X pSt bar 35
Pilot pressure range Hydraulic pSt bar 8.5 to 22.5
Electrohydraulic pSt bar 6.5 to 17.2
Required differential pressure Version S, C p bar 18
control on the control block
Recommended hydraulic pilot controls TH6 control curve 97, see data sheet 64552 or 64555

 RE 64276/04.2016, Bosch Rexroth AG


4 M4-12 | Control block
Technical Data

Hydraulic
Required pump controller Controller without LS connection to reservoir,
e.g., DFR1, DRS
Maximum primary pressure limitation p bar 370 (set at the factory according to ordering code),
min. 20 bar above the pressure cut-off value of the pump
LS pressure limitation p bar 50 to 350
(set at the factory according to ordering code)
The highest reduce response pressure of the valve
block LS pressure relief valves set at the factory must
be at least 20 bar lower than the pressure cut-off value
of the pump.
Maximum flow Inlet plate P P … P100 SP J SJ
Port P qVmax l/min 150 100 120 150 150
JZ JK PM JM
qVmax l/min 200 300 130 150
Directional valve
Port A, B qVmax l/min 130 with pressure compensator and load holding function
End plate LAPT LZPT
Port P qVmax l/min 100 100
Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524, HEES
(synthetic ester) according to ISO 15380 and other
hydraulic fluids on request
Hydraulic fluid temperature range θ °C -20 to 80
-40 to 100 on request
Viscosity range ν mm²/s 10 to 380
Maximum admissible degree of contamination of the Class 20/18/15, we recommend a filter with a minimum
hydraulic fluid retention rate of β10 ≥ 75
Cleanliness level as per ISO 4406 (c)

Electric
Electrical pilot control valve FTWE2K...; see data sheet 580071)
FTDRE2K...; see data sheet 580321)
Recommended amplifier RA 1-0/10; 1 axis, see data sheet 95230
(other actuating options on request) RA 2-1/10; 4 to 6 axes, see data sheet 95230
RC control units, see data sheet 95200
Connector version 1 and 3 Junior Timer, 2-pin (AMP)
8 and 9 DT04-2P (Deutsch)
Protection rating as per VDE 0470-1 Connector version 1 and 3 IP66, IP67 and IP69K
(DIN EN 60529), DIN 40050-9 (with Rexroth plug-in connector)1)
Connector version 8 and 9 IP66, IP 67 and IP 69K
(with installed and locked plug-in connector)1)
On-board electronics (EPM2) Data from page 49; see also instruction manual
64815-B
Spool position sensor See data sheet 95190

Notice
▶▶ Please contact us if the unit is to be used outside the
specified range of values.
▶▶ The technical data were determined at a viscosity of
ν = 32 mm²/sec (HLP46: 50 °C).

1) Plug-in connectors are not included and must be ordered separately,


see page 52.

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 5
 Modular system

Modular system

Control blocks in the M4-12 series have a modular structure. D: Electrohydraulic actuation W
They can be combined to provide the perfect solution for the E: Electrohydraulic actuation W with spool
application at hand. position sensor
F: Electrohydraulic actuation with on-board
Control block with lateral inlet plate electronics EPM2 CBA
1. Inlet plate 2.4 Actuation B side
A: Closed center with spool position sensor SJ A: Mechanical actuation Z with tongue
B: Mono block JM, combined with 1 spool axis B: Mechanical actuation N with hand lever
C: Open center P C: Standard cover –
D: Closed center J D: Mechanical actuation K with hand lever
2. Directional valves E: Mechanical actuation B2 with guide and
2.1 LS pressure limitation hand lever (aluminum-free)
2.2 Secondary pressure limitation 2.5 Electro-proportional LS pressure limitation
2.3 Actuation A side 3. End plate
A: Mechanical actuation A A: With LS unloading LA
B: Mechanical actuation M B: With LS port LZ
C: Hydraulic actuation H C: With two installation bores LAW…W…

2.2
E

2.4
D

2.
C

C B
B
A
A
3.

2.1

D
E
D 2.5 C
C

B B
2.3 1.
A

 RE 64276/04.2016, Bosch Rexroth AG


6 M4-12 | Control block
Modular system

Control block with central inlet plate


1. Central inlet plate JZ 2.4 Actuation B side
2. Directional valves A: Mechanical actuation Z with tongue
2.1 LS pressure limitation B: Mechanical actuation N with hand lever
2.2 Secondary pressure limitation C: Standard cover –
2.3 Actuation A side D: Mechanical actuation K with hand lever
A: Mechanical actuation A E: Mechanical actuation B2 with guide and
B: Mechanical actuation M hand lever (aluminum-free)
C: Hydraulic actuation H 2.5 Electro-proportional LS pressure limitation
D: Electrohydraulic actuation W 3. End plate
E: Electrohydraulic actuation W with spool A: Diversion plate LU
position sensor B: With two installation bores LUW…W…
F: Electrohydraulic actuation with on-board C: With LS unloading LA
electronics EPM2 CBA D: With LS port LZ
E: With two installation bores LAW…W…

2.2

2.4
D
2.

C
E
B
D 2.
C A

3.

2.1

1.

F
B
E

A
D
2.5
C
3.
2.3 B

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 7
 Modular system

Mono block E: Electrohydraulic actuation W with spool


1. Mono block PM, JM position sensor
(combined inlet, 1 spool axis and end plate) F: Electrohydraulic actuation with on-board
11 LS pressure limitation electronics EPM2 CBA
1.2 Secondary pressure limitation 1.7 Actuation B side
1.3 Primary pressure limitation A: Mechanical actuation Z with tongue
1.4 Electro-proportional LS pressure limitation B: Mechanical actuation N with hand lever
1.5 LS switch-off C: Standard cover –
1.6 Actuation A side D: Mechanical actuation K with hand lever
A: Mechanical actuation A E: Mechanical actuation B2 with guide and
B: Mechanical actuation M hand lever (aluminum-free)
C: Hydraulic actuation H 2. Flange-mountable directional valves
D: Electrohydraulic actuation W

2.

1.4 E

1.7
D

C
1.

1.3

012

1.1 1.2

F
1.5
E

1.6 B

 RE 64276/04.2016, Bosch Rexroth AG


8 M4-12 | Control block
Ordering code

Ordering code

Specifications on the name plate


The ordering code is used to record the technical features The complete control block is defined as per the type code
and requirements. according to DCCS 46001-10.
The Rexroth sales organization uses the ordering code to For recording the ordering code, the M4 configurator is
derive a short type and a material number. alternatively available at: www.boschrexroth.com/m4

Example: M4-12 control block with three directional valves

01 02 03 04 05 06 07 08 09 10 11 12
M4 – G12345 – 2 0 / 3 M4-12 J W21 – V_ 01 -450

01 Series: M4 load-sensing control block

02 6-digit control block number

03 Series 2X (unchanged installation and connection dimensions)

04 Series amendment status

05 Total number of spool axes (1 to 20)1)

06 Size, directional valve

07 Inlet plate

08 Actuation A side (mostly)

09 Actuation B side (mostly)

10 Sealing material

11 Line connections

12 Optional: Special designation

1) A maximum of 10 directional valves per side is possible. Always


indicate “9” for 10 or more directional valves.

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 9
 Ordering code

Ordering code sequence

M4-12-2X / Inlet plate

Directional valves

End plate, additional information

Inlet plate
01 02 03 04 05 06
M4-12-2X /

Design, system
01 Open center Lateral inlet plate P
Closed center Lateral inlet plate J
Lateral inlet plate with integrated switch-over axis SJ
Central inlet plate JZ
Central inlet plate for combination M4-12/M4-15 JK
Mono block Open center (installation of further directional valves is not possible) PM
Closed center (installation of further directional valves is possible; available only
JM
in variants …M…)

Primary pressure limitation


02 Without primary pressure relief valve (cannot be retrofitted, only for inlet JZ) Z
Without primary pressure relief valve (can be retrofitted, not possible with open center inlet P) Q
With primary pressure relief valve (specified pressure in bar, 3-digit, not possible with open center mono block PM) …

Pilot oil supply


03 With internal pilot oil supply Y
For external pilot oil supply X

Option 1
04 With LS switch-off (only in conjunction with inlet J, P) A
With LS damping nozzles, specifi- LS to pressure compensator Pressure compensator to LS
cation of the nozzle diameter in d = 0.6 d = 0.6 S0.6–0.6
mm (only in conjunction with
d = 0.6 d = 1.2 S0.6–1.2
inlet P)
d = 0.4 d = 1.2 S0.4–1.2
Without LS damping nozzles (can be retrofitted, only in conjunction with inlet P) N
With spool position sensor (only in conjunction with inlet SJ) S
Without spool position sensor (only in conjunction with inlet SJ) B

Option 1 – specification is only required for inlet SJ


05 External flow at port C 8 l/min Q008
26 l/min Q026
40 l/min Q040
90 l/min Q090
150 l/min Q150

Option 2
06 With unloading function, max. flow on the pump side 100 l/min (only in conjunction with inlet P) P100

= Preferred program

 RE 64276/04.2016, Bosch Rexroth AG


10 M4-12 | Control block
Ordering code

Directional valves
01 02 03 04 05 06 07 08 09 10 11 12 13
M4-12-2X / *
Spool axis 1

*
Spool axis 2

*
Spool axis 3, etc.

Pressure compensator
01 With pressure compensator, with load holding function S
Without pressure compensator, with load holding function (not in conjunction with PM) C
Without pressure compensator, without load holding function Q
With sensitive pressure compensator, with load holding function F
With 3-way pressure compensator (in conjunction with PM only) D
Without pressure compensator bore for switch-over axis Z

LS pressure limitation and housing variant1) 02 03 04


02 Without LS pressure relief valve (LS-PRV cannot be retrofitted; only Z or U are possible) Z Z
04 With threaded plug (Z not possible) Q Q
With LS pressure relief valve (specified pressure in bar, 3-digit; Z not possible) … …
With 1 LS pressure relief valve for same pressure setting in A and B (specified pressure in bar, 3-digit) = …
LS relief plug B B
03 Housing with measuring ports M
Housing without measuring ports Z
Housing for switch-over axis (only combination ZUZ possible) 2)
U
Housing for electro-proportional pressure limitation or switchable directional valves3) K
– 210 bar, decreasing characteristic curve 3)
L
– 210 bar, increasing characteristic curve3) J
– 350 bar, decreasing characteristic curve3) R
– 350 bar, increasing characteristic curve 3)
N
Housing for hydraulic pressure control, with LS and PST outlet3) C

Spool type4)
05 Main spool E E
Main spool J J
Main spool Q Q
Main spool with regeneration function R
Plunger cylinder as a consumer2) P
Floating position spool 2)
W
Floating position spool2) Y

Flow
06 Flow in consumer port A and B (parameter in l/min, 3-digit) …–…
Main spool with pressure function T (only in conjunction with E, J or Q)2) …T…
Main spool with pressure function T (only in conjunction with E) 2)
…M…

1) For possible housing/secondary valve combinations, see page 33


2) Please consult out technical sales department
3) Exact specifications in plain text, see information from page 24
= Preferred program
4) For symbols, see “Main spool” on page 26

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 11
 Ordering code

Actuation A side
07 Mechanical only Spring-centered A
With detent in 1 B1
With detent in 2 B2
With detent in 1, 2 B4
Mechanical 5)
Encapsulated, spring-centered M
Hydraulic6) H
Electrohydraulically proportional Standard W2
With measuring ports, on both sides W8
With damping nozzle + check valve for hydraulic superposition G2
Electrohydraulically switchable Standard W4
With damping nozzles, on both sides W5
With measuring ports, on both sides W6
With damping nozzle, with measuring ports, on both sides W7
With damping nozzle + check valve for hydraulic superposition G4
Electrohydraulic actuation with on-board Standard CBA
electronics (EPM2) With position sensor CPA

Supply voltage and connector version7) 24 V 12 V


08 Junior Timer, 2-pin (AMP) 1 3
DT04-2P (Deutsch) 8 9

Actuation B side
09 Mechanical only, spool end with tongue Z
Mechanical only, spool end with tongue and hand lever2) N
Standard cover –
Cover with hand lever8) Revolving Not revolving
Without hand lever R X
Hand lever position 60° K N
Hand lever position 0° L O
Hand lever position -60° M P

Secondary valves for consumer ports A and B 1)

10 None9) Flange surface2) F


11 Consumer port G 3/4 Z
Consumer port G 1/2 X
With threaded plug (secondary valves can be retrofitted) Q
With Shock/feed valve, adjustable A…
Shock/feed valve, non-adjustable H…

Optional special designation


12 One-sided actuation, two switching positions -011
With spool position sensor -S

13 Further specifications in plain text *

5) Always in conjunction with revolving hand lever 8) For more details and explanations, see “Variant overview” on page 30
6) For combination with mechanically superposed actuation (B side), 9) Secondary valves must be present in the hydraulic circuit
Bosch Rexroth recommends a non-revolving hand lever
7) Parameter only required with electrohydraulic actuation and with
= Preferred program
electro-proportional pressure limitation

 RE 64276/04.2016, Bosch Rexroth AG


12 M4-12 | Control block
Ordering code

End plate, additional information


01 02 03 04 05 06
M4-12-2X / *

End plate
01 With LS unloading LA
With additional P and T port LAPT
With two installation bores LA
Threaded plug Q Q
Electrohydraulically proportional W2 W2
Electrohydraulically switchable W4 W4
With three installation bores LA
Threaded plug Q Q Q Q Q Q
Pressure reducing valve (specified pressure in bar, 3-digit) … … …
4/2-way spool valve according to data sheet 18136-09
KKDER… KKDER… KKDER…
(specifications in plain text)
Without LS unloading LZ
With additional P and T port LZPT
Mono block, no end plate LM
Adapter plate for SP-08 directional valves + inlet pressure limitation
L8
(specified pressure in bar, 3-digit)
Adapter plate for ED1 and ED2 valves1) TI
Diversion plate for use with central inlet plate LU
With two installation bores LU
Threaded plug Q Q
Electrohydraulically proportional W2 W2
Electrohydraulically switchable W4 W4

Sealing material
02 FKM (fluoroelastomer) V_
NBR (nitrile rubber), FKM (fluoroelastomer) MV
NBR (nitrile rubber), FKM (fluoroelastomer) for low temperature range down to -40 °C (on request) MT

Pipe thread line connections


03 Inches according to ISO 228/12) 01
UNF according to ISO 11926/-13) 19
JIS B 2351-1 (on request) 64

Supply voltage and connector version4) 24 V 12 V


04 Junior Timer, 2-pin (AMP) 1 3
DT04-2P (Deutsch) 8 9

Optional special designation


05 Increased corrosion protection (seawater-resistant)1) -038
Aluminum-free -450
For safety-related applications -S

06 Further specifications in plain text *

1) Please consult out technical sales department


2) See “Line connections” on page 36.
3) For UNF thread, see data sheet 64272.
4) Parameter only required with electrohydraulic actuation and with
= Preferred program
electro-proportional pressure limitation

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 13
 Order examples

Order examples

Closed center with mono block and switch-over axis


Example: ––Three-fold control block with 3 directional valves Ordering codes:
––Variable pump qV, max = 150 l/min via inlet + 100 l/
min via end plate is possible
Inlet, com- ––Closed center, mono block Short type, inlet
bined with ––Without primary pressure relief valve 01 02 03
spool axis 1 ––With internal pilot oil supply
3 M4 – 12 – 2X / JM Z Y

––With pressure compensator, with load holding Spool axis 1


function 01 02 03 04 05 06 07 08 09 10 11
––With LS pressure relief valve for consumer port A
S 180 M Q J 100-100 W2 1 – H350 H350
180 bar, consumer port B plugged
––Spool symbol J
––Flow in A and B 100 l/min
––Type of actuation: electrohydraulically proportional
––With Junior Timer, 2-pin (AMP) 24 V
––Secondary valves: Pressure/feed valve, consumer
port A and B 350 bar (not adjustable)
Spool axis 2 ––Without pressure compensator, switch-over axis Spool axis 2
––Without LS pressure relief valve bore 01 02 03 04 05 06 07 08 09 10 11
––Housing for switch-over axis
Z Z U Z J 065-090 W4 1 – Z Z
––Spool symbol J
––Flow in C 65 l/min, 90 l/min for internal consumers
––Type of actuation: electrohydraulic switchable
––With Junior Timer, 2-pin (AMP) 24 V
––Without secondary valve (cannot be retrofitted)
Spool axis 3 ––With pressure compensator, with load holding Spool axis 3
function 01 02 03 04 05 06 07 09 10 11
––Without LS pressure relief valve bore
S Z Z Z J 085-085 CBA K Z Z
––Spool symbol J
––Flow in A and B 85 l/min
––Type of actuation: digital OBE
––Overriding hand lever (revolving)
––Without secondary valve (cannot be retrofitted)
End plate, ––Without internal LS unloading, with LS port, with End plate, additional information
additional P and T port 01 02 03
information ––FKM seals
LZPT V 01
––Pipe thread connections

A1 B1 C A3 B3

P P
X
Y
LS LSZ

a a a

b b b
P

A
T

T T
MB MA

 RE 64276/04.2016, Bosch Rexroth AG


14 M4-12 | Control block
Ordering code

Open center with lateral inlet plate


Example: ––Three-fold control block with 3 directional valves Ordering codes:
––Fixed pump qV, max = 150 l/min
Inlet ––Open center, lateral Short type, inlet
––With primary pressure relief valve, set to 300 bar 01 02 03
––With internal pilot oil supply
3 M4 – 12 – 2X / P 300 Y

Spool axis 1 ––Without pressure compensator, with load holding Spool axis 1
function 01 02 03 04 05 06 07 09 10 11
––With LS pressure relief valve for consumer port A
C 250 M B E 050-000 A Z A230 Q
250 bar and LS relief plug in B
––Spool symbol E
––Flow in A 50 l/min, port B plugged
––Type of actuation: mechanical, spring-centered,
not encapsulated, with tongue
––Secondary valve: adjustable shock/feed valve for
actuator port A 230 bar, secondary valve bore B
plugged
Spool axis 2 ––Without pressure compensator, without load hold- Spool axis 2
ing function 01 02 03 04 05 06 07 09 10 11
––With 1 LS pressure relief valve for consumer ports
Q = M 275 E 100-100 H – H100 A230
A and B 275 bar
––Spool symbol E
––Flow in A and B 100 l/min
––Type of actuation: hydraulic
––Secondary valve: non-adjustable shock/feed valve
for actuator port A 100 bar, adjustable shock/
feed valve for consumer port B 230 bar
Spool axis 3 ––With pressure compensator, with load holding Spool axis 3
function 01 02 03 04 05 06 07 08 09 10 11
––Without LS pressure relief valve bore
S Z Z Z J 070-070 W7 8 X Z Z
––Spool symbol J
––Flow in A and B 70 l/min
––Type of actuation: electrohydraulically switchable,
with damping nozzle, with measuring ports
––With DT04-2P connector (Deutsch) 24 V
––Hand lever cover, not revolving, without hand lever
––Without secondary valve (cannot be retrofitted)
End plate, ––With internal LS unloading End plate, additional information
additional ––FKM seals 01 02 03
information ––Pipe thread connections
LA V 01

M X A1 B1 a b A2 B2 Mb A3 B3

P
Y
LS
a

b
P

A
T

T
MB MA MA Ma

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 15
 Ordering code

Closed center with central inlet plate


Example: ––Two-fold control block with 2 directional valves Ordering codes:
––Variable pump qV, max = 200 l/min
Short type, ––Diversion plate Short type, diversion plate
diversion 01
plate 2 M4 – 12 – 2X / LU

Spool axis 1 ––With pressure compensator, with load holding Spool axis 1
function 01 02 03 04 05 06 07 08 09 10 11
––Without LS pressure relief valve bore S Z Z Z E 100-100 W6 1 K Q Q
––Spool symbol E
––Flow in A and B 100 l/min
––Type of actuation: electrohydraulically proportional
with measuring ports on both sides
––With Junior Timer, 2-pin (AMP) 24 V
––Overriding hand lever (revolving)
––Secondary valve bores plugged
Inlet ––Closed center, central Inlet
––With primary pressure relief valve, set to 300 bar 01 02 03
––With internal pilot oil supply JZ 300 Y

Spool axis 2 ––With pressure compensator, with load holding Spool axis 2
function 01 02 03 04 05 06 07 09 10 11 13
––With LS pressure relief valve for consumer port A S 270 L 300 E 090-090 CBA K Q Q KBPSL8BA
270 bar, consumer port B 300 bar
––With electro-proportional Pressure limitation,
210 bar (decreasing characteristic curve)
––Spool symbol E
––Flow in A and B 90 l/min
––Type of actuation: digital OBE
––Overriding hand lever (revolving)
––Secondary valve bores plugged
End plate, ––With internal LS unloading End plate, additional information
additional ––FKM seals 01 02 03
information ––Pipe thread connections LA V 01

Mb A1 B1 LS P Y MP X A2 B2
P
X
Y
LS

a a

b b
P

A
T

T
Ma T MB MA

 RE 64276/04.2016, Bosch Rexroth AG


16 M4-12 | Control block
Ordering code

Closed center with combination inlet plate for M4-12 and M4-15 directional valves
Example: ––Three-fold control block with 3 directional valves Ordering codes:
––Variable pump qV, max = 200 l/min
Short type, ––Diversion plate Short type, diversion plate
diversion 01
plate
3 M4 – 15 – 2X / LU

M4-15 spool ––With pressure compensator, without load holding Spool axis 1
axis 1 function 01 02 03 04 05 06 07 09 10 11
––With LS pressure relief valve for consumer port A
T 230 M B E 190-000 CBA K Q Q
230 bar and LS relief plug in B
––Spool symbol E
––Flow in A 190 l/min, port B plugged
––Type of actuation: digital OBE
––Overriding hand lever (revolving)
––Secondary valve bores plugged
Inlet ––Central closed center for M4-12/M4-15 Inlet
––With primary pressure relief valve, set to 280 bar 01 02 03
––With internal pilot oil supply
JK 280 Y

M4-12 spool ––With pressure compensator, with load holding Spool axis 2
axis 2 and 3 function 01 02 03 04 05 06 07 09 10 11
––With LS pressure relief valve for consumer port A
S 180 M 120 E 090-090 CBA – Z Z
180 bar, consumer port B 120 bar
––Spool symbol E
Spool axis 3
––Flow in A and B 90 l/min
––Type of actuation: digital OBE 01 02 03 04 05 06 07 09 10 11
––Without secondary valve bores S 180 M 120 E 090-090 CBA – Z Z

End plate, ––With internal LS unloading End plate, additional information


additional ––FKM seals 01 02 03
information ––Pipe thread connections
LA V 01

A1 B2 LS P Y M X A2 B2 A3 B3
P
X
Y
LS

a a a

b b b
P

A
T

T
MB MA T MB MA MB MA

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 17
 Inlet plates

Inlet plates

Open center (P)

With primary pressure relief valve, with internal pilot


oil supply X
Ordering code:
P … Y

▶▶ Specified pressure in bar required after P (3-digit)

M
P Y LS T

With LS switch off


Ordering code:
P … X A

▶▶ LS line connected to the Y-line to the reservoir in


de-energized condition
▶▶ All downstream M4-12 sections remain in load holding
M
P LS Y T

With LS damping nozzle and sensitive pressure


compensator X
Ordering code:
P Q X S0.6–0.6 P100

▶▶ Nozzle diameter parameter in mm required after S


(standard: 0.6–0.6)
▶▶ Sensitive unloading function
▶▶ Maximum flow 100 l/min on the pump side
M
P Y LS T

Pilot oil supply (Y)


▶▶ Pressure limitation 45 bar
▶▶ Pilot pressure max. 30+5 bar
Notice
With internal pilot oil supply, pilot oil for other consumers
can also be directed via the X port. However, this can
affect the switching times on the M4-12. Please consult
technical sales for information about potential impacts.
With an external pilot oil supply, the X port is not generally
plugged. It must be plugged if it is not in use (e.g. with
hydraulic control H).

 RE 64276/04.2016, Bosch Rexroth AG


18 M4-12 | Control block
Inlet plates

Closed center (J)

With primary pressure relief valve, for external pilot


oil supply
Ordering code:
M
J … X
P X Y LS T
▶▶ Specified pressure in bar required after J (3-digit)

Without primary pressure relief valve, with internal pilot


oil supply X

Ordering code:
J Q Y

M
P Y LS T

Without primary pressure relief valve, with internal pilot


oil supply, with LS switch-off X

Ordering code:
J Q Y A

▶▶ LS line connected to the Y-line to the reservoir in M


de-energized condition P LS Y T
▶▶ All downstream M4-12 sections remain in load holding

With integrated switch-over axis, primary pressure relief


valve and internal pilot oil supply
Ordering code: C

SJ 350 Y D Q080

▶▶ Specified pressure in bar required after SJ (3-digit)


▶▶ With switching position detection of the integrated
switch-over axis
▶▶ For external flow (port C) of 80 l/min
▶▶ Switch-over axis actuation with on/off valves type
FTWE2K according to data sheet 58007
S1 S2
▶▶ Further information is available on request

Y LS P M T

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 19
 Inlet plates

Central closed center inlet plates (JZ, JK)

With primary pressure relief valve, for external pilot


oil supply X

Ordering code:
M
JZ … X
Y
▶▶ Specified pressure in bar required after JZ (3-digit) P T
LS

Without primary pressure relief valve, with internal pilot


oil supply X

Ordering code:
M
JZ Q Y
Y
P T
LS

Without primary pressure relief valve, with internal pilot


oil supply X 160-200 μm

Ordering code:
M
JZ Z Y
Y
▶▶ Primary pressure relief valve is not retrofittable P T
LS

For connection of directional valves of NG 12 and 15, M4-12


without primary pressure relief valve, with internal pilot
X 160-200 μm
oil supply
Ordering code:
M
JK Q Y
Y
P T
LS
M4-15

For connection of directional valves of NG 12 and 15, M4-12


without primary pressure relief valve, for external pilot
X
oil supply
Ordering code:
M
JK Q X
Y
P T
LS
M4-15

 RE 64276/04.2016, Bosch Rexroth AG


20 M4-12 | Control block
Mono block

Mono block

Mono block open center, with primary pressure relief


B
valve, with internal pilot oil supply
Ordering code:
PM Z Y MA

D = M … J …-… W2 1 – H… H… A
A B
b
LM V 01
a P T
▶▶ Primary pressure limitation via pressure compensator
and LS-PRV
X

P Y T

Mono block closed center, without primary pressure


B
relief valve, with internal pilot oil supply
Ordering code:
JM Z Y MA
MB
S Q M … J …-… W2 1 – H… H… A
A B
b
LM V 01
a P T

P X Y LS T

Mono block closed center, without primary pressure


B
relief valve, for external pilot oil supply, for installation
of further directional valves
Ordering code: MA
JM Z X MB
A
A B
S … M … J …-… W2 1 – H… H… b

Notice a P T

Design by technical sales.

P X Y LS T

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 21
 Directional valves

Directional valves

Pressure compensator In the main spool central position there is no connection


from P to the consumer ports A and B. Pump pressure
▼▼ Main spool in central position shifts the compensator spool (1) to the left against the
A B spring (2) in this operating condition.
When the main spool (3) (= metering orifice) is actuated, the
LS pressure reaches the spring chamber (4) and shifts the
T T pressure compensator spool to the right into the control
X position. The flow is also kept constant in parallel operation
of consumers with different load pressures.
The pressure compensator S is equipped with load holding
P function. This function is not free of leakage oil.
LSP It is equipped with a disc (5) as standard. The number of
discs fitted depends on the required flow.
MA MB
4 2 5 1 3
▼▼ Main spool actuated Type Summary Symbol
▶▶ With pressure compensator
A B
S ▶▶ With load holding function1)
▶▶ Maximum flow 130 l/min
▶▶ Without pressure compensator
T T C ▶▶ With load holding function1)
X ▶▶ Maximum flow 140 l/min
▶▶ Without pressure compensator
Q ▶▶ Without load holding function
P ▶▶ Maximum flow 140 l/min

LSP ▶▶ With pressure compensator


F ▶▶ With load holding function1)
MA MB ▶▶ Sensitive to flows up to 20 l/min
4 2 5 1 3
D2) ▶▶ With open center unloading valve

▼▼ Flow control by pressure compensator


1) This load holding function is not free of leakage oil
120 2) Only in conjunction with mono block design PM

100

80
Flow [l/min]

60

40

20

0 50 100 150 200 250 300


Pressure difference [bar]

 RE 64276/04.2016, Bosch Rexroth AG


22 M4-12 | Control block
Directional valves

LS pressure limitation

▼▼ Consumer flow reduction by LS pressure limitation

100

80
Flow [%]

60

40

20

0 50 100 150 200 250 300 350


Setting (example)
LS pressure [bar]

Minimum setting: 50 bar


Maximum setting: 385 bar

With LS pressure relief valve and LS threaded plug P X Y LS T


Ordering code:
B
S … M Q J …–… W2 1 – H… H…

▶▶ Specified pressure in bar for consumer port A (3-digit)


MA
▶▶ Threaded plug for consumer port B MB
▶▶ With the QMQ design, LS pressure limitation can be A
retrofitted onto the directional valve. A B
b
▶▶ The LS pressure can be influenced externally via ports
a P T
MA and MB. These ports can also be used as measuring
ports.

With 1 LS pressure relief valve P X Y LS T


Ordering code:
B
S = M … J …–… W2 1 – H… H…

▶▶ Only 1 LS-PRV for the same pressure setting in A and B,


MA
specified pressure in bar (3-digit)
▶▶ 1 measuring port A
A B
b

a P T

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 23
 Directional valves

With LS pressure relief valve and relief plug P X Y LS T


Ordering code:
B
S … M B J …-000 W2 1 – H… Q

▶▶ Specified pressure in bar for consumer port A (3-digit)


MA
▶▶ Relief plug for consumer port B MB
▶▶ E.g., for cylinders actuated on one side A
A B
b

a P T

Without LS pressure relief valves P X Y LS T


Ordering code:
B
S Z Z Z J …–… W2 1 – H… H…

▶▶ LS-PRV cannot be retrofitted


▶▶ Housing without measuring ports
A
A B
b

a P T

Housing for switch-over axis P X Y LS T


Ordering code:
Z Z U Z J …–… W4 1 K Z Z

▶▶ Housing for switch-over axis


▶▶ Maximum flow of internal consumers 90 l/min
C
b A B

a P T

 RE 64276/04.2016, Bosch Rexroth AG


24 M4-12 | Control block
Directional valves

Housing for electro-proportional LS pressure P X Y LS T


limitation/hydraulically switchable directional valves
B
Distinction between:
1. Type KBPS
2. KBPS housing and plug
3. KBPS porting pattern and cover plate
A
4. Type MH2DAD and type KBPS A B
5. Type KKDE
b
6. Type MHDRD2 P T M
a

The exact designation of the valve must be specified


in plain text as follows.

1. Electro-proportional LS pressure relief valve type KBPS


M M
(see also data sheet 18139-04; 18139-05)

Preferred program:
S … L … J …–… H – H… H… KBPSL8BA

S … J … J …–… H – H… H… KBPSL8AA
KBPS…BA: KBPS…AA:
S … R … J …–… H – H… H… KBPSR8BA Decreasing characteris- Increasing characteristic
tic curve curve
S … N … J …–… H – H… H… KBPSR8AA

Supplementary program, e.g.:


S … K … J …–… H – H… H… KBPSH8BA -033

▼▼ Pressure control by electro-proportional LS pressure limitation


Additional
Decreasing Increasing
SO no. 450
characteristic characteristic
(Option:
curve curve 400
Pressure in the main port 1 [bar]

24 V; 0.8 A)
1
50 bar KBPSC8BA KBPSC8AA 350
3
100 bar KBPSF8BA KBPSF8AA 300
150 bar KBPSH8BA KBPSH8AA 250
2 4
210 bar KBPSL8BA (2)
KBPSL8AA (4)
-033 200
250 bar KBPSN8BA KBPSN8AA
150
315 bar KBPSP8BA KBPSP8AA
350 bar KBPSR8BA (1)
KBPSR8AA (3) 100

420 bar KBPST8BA KBPST8AA 50

= Preferred program 0 25 50 75 100


Setpoint [%]

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 25
 Directional valves

2. Housing KBPS and plug


M
S … K … J …–… H – H… H… Q

Plug

3. Porting pattern KBPS and cover plate


S … K … J …–… H – H… H… A

Cover plate

4. Pressure cut-off valve type MH2DAD and electro- MLS PLS


proportional LS pressure relief valve type KBPS
(see also data sheet 64586; 18139-04, 18139-05)
S … K … J …–… H – H… H… MH2DAD+KBPSH8BA

S … K … J …–… H – H… H… MH2DAD+Q

5. 2/2-way spool valve type KKDE


M M
(see also data sheet 18136-08)
S … K … J …–… H – H… H… KKDER8PA

▶▶ Normally open: KKDER8PA


▶▶ Normally closed: KKDER8NA
Notice
KKDE…PA: KKDE…NA:
The consumer pressure is not depressurized!
Normally open Normally closed

6. Hydraulic pressure control MHDRD2


Q … C … J …–… H – H… H… MHDRD2

▶▶ Pressure distortion of the LS signal P X Y LS T


related to the pilot pressure
B
▶▶ Application example: Slew drive in the crane
▶▶ Design by technical sales

A
A B

b Ma/b
P T
a

 RE 64276/04.2016, Bosch Rexroth AG


26 M4-12 | Control block
Directional valves

Main spool
Hydraulic cylinder as consumer Regeneration function (P, B → A) Plunger cylinder as a consumer
E R P
A MBMA B A MBMA B A MBMA B

P LS T P LS T P LS T

Hydraulic motors as consumers Floating position Spool with pressure function1)


J W (E, J, Q) …T…
A MBMA B A MBMA B
A MBMA B

P LS T P LS T
P LS T

Application with defined residual


opening (A/B → T) , consumer port Pressure main spool in connection
unloaded in neutral position Floating position1) with lowering brake valve1)
Q Y (E) …M…

A MBMA B A MBMA B A MBMA B

P LS T P LS T P LS T

▼▼ Characteristic curves symmetric main spool P → A/B ▼▼ Characteristic curves floating position spool P → A/B

140 100
1
120 2
80
3
Nominal flow [l/min]

100
Typical flow [l/min]

Typical flow [l/min]

4 60
80
W spool
5
60 40
6
40
7 20
20 8
9
10
0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 1 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 1
Current [A] Current [A]

0.89 1.0 1.12 1.23 1.34 1.45 1.56 1.68 1.8 2 0.89 1.0 1.12 1.23 1.34 1.45 1.56 1.68 1.8 2
Current [A] Current [A]

8.5 10 12 14 16 18 20 22.5 3 8.5 10 12 14 16 18 20 22.5 3


Pilot pressure [bar] Pilot pressure [bar]

0 50 100 150 200 250 4 0 50 100 150 200 250 4


Setpoint value [digits] 254 Setpoint value [digits] 254

1 Electrohydraulic actuation, 24 V control


2 Electrohydraulic actuation, 12 V control
3 Hydraulic actuation
4 Digital on-board electronics (EPM2)

1) Design by technical sales

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 27
 Directional valves

Flow
Symmetric main spool
Pressure
Spool type compen- Flow in l/min
sator
130–130 (1) 100-100 073-073 052-052 034-034 023-023 014-014 007-007
S 120-120 (2) 085–085 (4)
065-065 (5) 045-045 (6) 030-030 (7) 020-020 (8) 012-012 (9) 006-006 (10)
E, J, Q
100-100 (3) 070-070 057-057 038-038 026-026 017-017 010-010 005-005
C 140-140 115-115 090-090 063-063 042-042 028-028 017-017 008-008

(1)
… (10)
Note on spool characteristic curve page 26.

Asymmetric main spool


Pressure
Spool type compen- Flow in l/min
sator
100-073 100-052 052-034 034-023 023-014
S 085-065 085-045 045-030 030-020 020-012
E, J, Q
070-057 070-038 038-026 026-017 017-010
C 115-090 115-063 063-042 042-028 028-017

Floating position, regeneration and plunger spool1)


Pressure
Spool type compen- Flow in l/min (others on request)
sator
W 030-030 045-045 065-040
Y 030-030 065-065 065-045 065-085 085-100
S
R 130-101 085-030 065-025 130-140
P 185-000

Notice
Design by technical sales.

Example: Solution:
▶▶ Spool type J ▶▶ 85-liter spool + 2 discs = 100 l/min
▶▶ Pressure compensator S ▶▶ Set 90 liters via stroke limiter.
▶▶ Setpoint value: qconsumers = 90 l/min
Spool type Pressure Flow in l/min Number of discs
compensator
100-100 With 2 discs (pressure compensator Δp = 8.5 to 11.5 bar)
E, J, Q S 085-085 With 1 disc (pressure compensator Δp = 6 to 9.5 bar)
070-070 Without disc (pressure compensator Δp = 4 to 7 bar)

Notice
Place directional valves with maximum flow as close as
possible to the inlet plate.

1) Flow parameter corresponds to 1 disc

 RE 64276/04.2016, Bosch Rexroth AG


28 M4-12 | Control block
Types of actuation

Types of actuation

Mechanical only (not encapsulated) with tongue Mechanical only (not encapsulated) with hand lever and detent
AZ B1N
A B A B

P T P T

▶▶ Centering in central position by means of springs in case ▶▶ Centering in central position by means of springs in case of
of non-actuation. non-actuation.
▶▶ For variants, see page 29.
Mechanical (encapsulated) Hydraulic
M 1) 2) H
A BA B A B
X
b a
Y
P TP T P T

▶▶ Centering in central position by means of springs in case ▶▶ Centering in central position by means of springs in case
of non-actuation. of non-actuation.
▶▶ All hand lever position options are possible, cf. also ordering ▶▶ Recommended hydraulic pilot controls:
codes on page 30. Type 2TH6 and 4TH6 according to data sheet 64552 or 64555
1) Revolving hand lever

2) Non-revolving hand lever

Electrohydraulically switchable Electrohydraulically switchable with damping nozzle on both sides


W4 W5
X A B X b A B
Y Y
P T a P T

▶▶ On/off valve type FTWE2K according to data sheet 58007 ▶▶ On/off valve type FTWE2K according to data sheet 58007
Electrohydraulically switchable with measuring ports on both sides Electrohydraulically switchable with damping nozzle, with
measuring ports on both sides
W6 W7
Mb Mb
X A B X b A B
Y Ma Y Ma
P T a P T

▶▶ On/off valve type FTWE2K according to data sheet 58007 ▶▶ On/off valve type FTWE2K according to data sheet 58007
Electrohydraulically proportional Electrohydraulically proportional with measuring ports
on both sides
W2 W8
Mb
Y b A B Y b A B
X X
Ma
a P T P T
a

▶▶ FTDRE2K proportional pressure reducing valve as per data sheet ▶▶ FTDRE2K proportional pressure reducing valve as per data sheet
58032 58032

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 29
 Types of actuation

Electrohydraulically proportional with damping nozzle and check valve Electrohydraulically switchable with damping nozzle and check
for hydraulic superposition valve for hydraulic superposition
G2 G4
b b

Y X b A B
b A B
a a
X Y
P T a P T
a

▶▶ FTDRE2K proportional pressure reducing valve as per data sheet ▶▶ FTDRE2K on/off valve as per data sheet 58007
58032
Electronic pilot module Electronic pilot module with position sensor
CBA CPA

Y A B Y A B
b b
X X
a P T a P T

▶▶ Digital interface, standard, refer to instruction manual 64815-B ▶▶ Digital interface, with position sensor, refer to instruction manual
64815-B

Variant overview for mechanical actuation only (not encapsulated)

Spring-centered + tongue Spring-centered + tongue


with lever

AZ AN

Detent + tongue Detent + tongue with lever Lever position

B1 Z B1 N B1 = detent in 1
A B 1
0
2
B2 Z B2 N 2 0 1 B2 = detent in 2

P T
B4 Z B4 N B4 = detent in 1, 2

Actuating force:
Tongue < 250 N (spool axis)

 RE 64276/04.2016, Bosch Rexroth AG


30 M4-12 | Control block
Types of actuation

Variant overview for mechanical actuation with hand lever (encapsulated)


▼▼ Standard cover with hand lever ▼▼ Cover with clamping piece and hand lever, ▼▼ Lever screw fitting on the
aluminum-free mounting piece
(e.g., lever screw fitting in position 2)

±1°
20° 1° 60° = B2, G2
23°
±

°± °
20 °±1 30° = B12, G12 1
1 23 60° = K, N

0° = F2, H2
2

0° = L, O

-30° = D12, J12 3


-60° = M, P

1 Actuation angle for revolving lever -60° = D2, J2


2 Actuation angle for non-revolving lever

Ordering code
Standard cover Clamping piece with lever Clamping piece without lever
Lever Revolving Not revolving Revolving Not revolving Revolving Not revolving
2 2
Upward, 60° K N B G T Q
3 3
2 2
Upward, 30° B1 G1 T1 Q1
3 3
1 1
Straight, 0° L O F 2 H 2 U S
3 3
1 1
Downward, -30° D1 J1 V1 C1
2 2
1 1
Downward, -60° M P D J V C
2 2
Without lever R X

Actuating force (on the hand lever) Notice


▶▶ Mechanical < 20 N ▶▶ Revolving hand lever:
▶▶ Mechanical superposition Mechanical actuation can override the electrohydraulic
(with parallel hydraulic actuation) < 70 N actuation. The hand lever is directly connected to the
▶▶ Mechanical superposition main spool and follows the spool movement in electro-
(with parallel electrohydraulic actuation) < 50 N hydraulic control.
▶▶ Non-revolving hand lever:
= Preferred program The hand lever is connected to the main spool via a
coupling. If the main spool is in the central position,
the hand lever can be snapped into place. With elec-
trohydraulic control, it does not follow the spool move-
ment in this way.

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 31
 Secondary valves

Secondary valves

Shock/feed valves, non-adjustable P X Y LS T


Ordering code:
B
S … M … J …–… H – Q H…

▶▶ Non-adjustable shock/feed valve


MA
▶▶ Specified pressure in bar required after H (3-digit), MB
see table below for possible values A
▶▶ Example: Q H150 A B

Q: Threaded plug for consumer port A H150: Shock/ b


P T
feed valve, fixed setting to 150 bar for consumer port B a
Notice
Only suitable for reduction of pressure peaks, not to be
used as a pressure relief valve!

Possible pressure settings for shock valves with feed function


Pressure setting in bar for consumer port A and B
H025 = 25 bar H125 = 125 bar H210 = 210 bar H320 = 320 bar
H035 = 35 bar H140 = 140 bar H230 = 230 bar H350 = 350 bar
H050 = 50 bar H150 = 150 bar H240 = 240 bar H380 = 380 bar
H063 = 63 bar H160 = 160 bar H250 = 250 bar H405 = 405 bar
H080 = 80 bar H175 = 175 bar H280 = 280 bar H420 = 420 bar
H100 = 100 bar H190 = 190 bar H300 = 300 bar

Notice
Shock valves have a fixed setting!

Shock/feed valves, adjustable P X Y LS T


Ordering code:
B
S … M … J …–… H – Q A…

▶▶ Adjustable shock/feed valve


MA
▶▶ Specified pressure in bar required afterA (3-digit) MB
▶▶ Example: Q A200 A
Q: Threaded plug for consumer port A A200: Shock/ A B

feed valve, set to 200 bar for consumer port B b


P T
Notice a
Only suitable for reduction of pressure peaks, not to be
used as a pressure relief valve!

Adjustable pressure stages in bar for consumer port A and B


10 – 70 201 – 270
71 – 120 271 – 320
121 – 200 321 – 380

 RE 64276/04.2016, Bosch Rexroth AG


32 M4-12 | Control block
Options

Without secondary valves P X Y LS T


Ordering code:
B
S … M … J …–… H – Z Z

▶▶ Secondary valves are not retrofittable


MA
▶▶ Consumer port G 3/4 MB
Ordering code: A
A B
S … M … J …–… H – X X
b
▶▶ Secondary valves are not retrofittable P T
a
▶▶ Consumer port G 1/2
Notice
Secondary pressure limitation must be provided by the
customer if necessary.

Without secondary valves, secondary valves, with flange P X Y LS T


surface
B
Ordering code:
S … M … J …–… H – F F … …
MA
▶▶ Secondary valves are not retrofittable MB
▶▶ Flange-mountable valves specified in the plain text A
A B
Notice
b
▶▶ Secondary pressure limitation must be provided by the P T
customer if necessary. a
▶▶ Design by technical sales.

Options

Electrohydraulic, with spool position sensor P X Y LS T


Ordering code:
B
S … M … J …–… W2 1 K H… H… -S

▶▶ Main spool neutral position and A and B direction of


MA
motion detected and monitored by an analog voltage MB
output signal A
▶▶ Pin assignment for connector A B
b
(connector version DT04-4P DEUTSCH)
a P T

Pin 4 Pin 1

Pin 3 Pin 2

Notice
Pin 1: +VBatt
Pin 2: GND ▶▶ Design by technical sales.
Pin 3: Sensor signal for flow direction of consumer port B For further information, see data sheet 95190.
Pin 4: Sensor signal for flow direction of consumer port A

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 33
 Available housing variants

Available housing variants

With secondary Without secondary Without secondary Flange surface


valve option valve valve without secondary
(can be retro- (cannot be retro- (cannot be retro- valve option
fitted) fitted) fitted) (cannot be retro-
fitted)
Q, A…, H… XX ZZ FF
A, B = G 1/2 G 1/2 G 3/4

Without LS pressure relief valve


ZZZ ● ● ●
(LS-PRV cannot be retrofitted)

Without LS pressure relief valves for switch-over


ZUZ ●
axis (LS-PRV cannot be retrofitted)
Standard

With only 1 LS pressure relief valve for same


= M… ● ●
pressure setting in A and B

With 2 LS pressure relief valves,


…M… ● ● ● ●
(specified pressure in bar, 3-digit)

With LS pressure relief valves (specified pressure


in bar, 3-digit)
…K… ● ●
Housing for electro-proportional or switchable
pressure limitation

Without LS pressure relief valve


ZZZ ● ●
(LS-PRV cannot be retrofitted)

With only 1 LS pressure relief valve for same


= M…
pressure setting in A and B

With 2 LS pressure relief valves,


…M… ● ● ●
Mechanical only

(specified pressure in bar, 3-digit)

With LS pressure relief valves (specified pressure


in bar, 3-digit)
…K…
Housing for electro-proportional or switchable
pressure limitation
Without LS pressure relief valve (LS-PRV cannot
be retrofitted)
ZKZ ●
Housing for electro-proportional or switchable
pressure limitation

Housing for hydraulic pressure control, with LS


…C… ●
and PST outlet

● = available

 RE 64276/04.2016, Bosch Rexroth AG


34 M4-12 | Control block
End plates

End plates

With LS unloading
Ordering code:
LA LS T

End plate LA with additional P and T port P T


Ordering code:
LAPT
LS

With LS port LSZ


Ordering code:
LZ

▶▶ LS unloading must be provided externally

End plate LZ with additional P and T port P LSZ T


Ordering code:
LZPT

▶▶ LS unloading must be provided externally

LA end plate with two installation bores for FTDRE4K, PXY C1 C2 T


FTWE4K1)
Ordering code:
LA W4 W2

▶▶ For 30 bar pilot pressure


▶▶ See also data sheet 58038 and/or 58008

LS

End plate LA with two installation bores for pressure C1 C2 C3 C4 C5 C6


reducing valve, KKDER... 1)

Ordering code:
LA … KKDER… … KKDER… Q Q

▶▶ Max. 40 l/min per working port


▶▶ See also data sheet 18136-09 Y

P X Y LS T

1) Please consult out technical sales department

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 35
 End plates

Diversion plate for use with central inlet plate LS


Ordering code:
LU

Diversion plate LU with two installation bores for LS


FTDRE4K, FTWE4K1)
Ordering code:
LU Q W4

▶▶ For 30 bar pilot pressure


▶▶ See also data sheet 58038 and/or 58008

PXY C1 C2 T

Adapter plate for SP-08 directional valves


SP-08
Ordering code:
L8 210

▶▶ With integrated 2-with pressure compensator


▶▶ With LS pressure relief valve, set to 210 bar
▶▶ Ordering code for flanged SP-08 directional valves in
accordance with data sheet 64139
▶▶ A maximum of 7 directional valves M4-12 is permissible
P X Y LS M4-12 T

Adapter plate for Bosch Rexroth Oil Control ED valves


P1 ED... T
Ordering code:
TI

▶▶ Please consult technical sales for ordering code


for flanged ED directional valves.
LS

P X Y LS M4-12 T T

 RE 64276/04.2016, Bosch Rexroth AG


36 M4-12 | Control block Dimensions [mm]
Dimensions

Dimensions

Line connections
Ports
P Pump LS Load sensing signal
A, B Consumer LSZ LS supply
a, b Pilot oil M Measuring port, pump
T Reservoir MA, MB Measuring port, LS pressure
X Pilot oil supply Mb, Mb Measuring port, pilot pressure
Y Pilot oil return C External consumers

Line connections as pipe threads (code 01)


P T A, B a, b LS X, Y M, MA, MB Ma, Mb C, C1…C6
Inlet P G 3/4 G1 – – G 1/4 G 1/4 G 1/4 – –
J G 3/4 G 3/4 – – G 1/4 G 1/4 G 1/4 – –
JZ G1 G1 – – G 1/4 G 1/4 G 1/4 – –
JK G 1 1/4 G 1 1/4 – – G 1/4 G 1/4 G 1/4 – –
Mono block PM, JM G 3/4 G 3/4 G 1/2 G 1/4 G 1/4 G 1/4 G 1/4 – –
Directional With secondary – – G 1/2 G 1/4 – – G 1/4 G 1/8 –
valve valves
Without second- – – G 3/4 G 1/4 – – G 1/4 G 1/8 G 3/4
ary valve (ZZ)
Without second- – – G 1/2 G 1/4 – – G 1/4 G 1/8 –
ary valve (XX)
End plate LZ – – – – G 1/4 –
LAPT, LZPT G 3/4 G 3/4 – – G 1/4 – – – –
LA… … G 1/2 G 3/8 – – G 1/4 G 1/4 – – G 1/4
LU… … G 1/2 G 3/8 – – G 1/4 G 1/4 – – G 1/4

Mounting bolts M10 as per EN ISO 4762 or EN ISO 4014:


Tensile strength class 8.8 10.9
Tightening torque 41±2 Nm 60±3 Nm

Ports as per ISO 1179-1

Bosch Rexroth AG, RE 64276/04.2016


Control block | M4-12 37
Dimensions [mm]
Dimensions

Inlet plates

▼▼ Lateral inlet plate J…Y ▼▼ Lateral inlet plate P…Y

103 103
25 25

12
M10; 15 deep

12
M10; 15 deep
48 48 13.5

4
Y

LS X M

114
Y

114
X

92
LS

51.5
44.5
54

50
40
27

25
13 35
50 4 65 4
38.5 45
65 91.5
89 132
125
26

43
T
28

T P

48
45
85 91.5 48

▼▼ Central inlet plate JZ ▼▼ Central inlet plate JK

112.5 125
34.5 12
15
27
25

12

80
65
M10; 15 deep 30 78 35
48 90
M10; 15 deep
MP
114

X
130
93
43

LS X
25

47

Y
40
25

Y
137 15
153 14
P 64
27

70
53
65

P
T
60

T LS
46

37
76 ca. 34 40 ca. 48
99 105

 RE 64276/04.2016, Bosch Rexroth AG


38 M4-12 | Control block Dimensions [mm]
Dimensions

Mono block

▼▼ Standard mono block Closed Center JM as input plate combined with 1 axis; further directional valves are flange-mountable

47
27
Fastening thread
103
2 × M10; 19 deep

125 36.5

T
Y

20.5
93

LS
68

63
P
52
37.5

29

89
16.5

15 107.5
18
44.5
72
78.5

94

50
15.5

37

88
94

17.5

168

Bosch Rexroth AG, RE 64276/04.2016


Control block | M4-12 39
Dimensions [mm]
Dimensions

▼▼ Standard mono block Open Center PM (installation of further directional valves is not possible)

43
Fastening thread
95 3 × M10; 19 deep

125

124
119

98.5

87.5
72

33

19
15 40

18 67

72 114.5

78.5

94

50
41

98

 RE 64276/04.2016, Bosch Rexroth AG


40 M4-12 | Control block Dimensions [mm]
Dimensions

Directional valves
▼▼ Housing with secondary valve bore, ▼▼ Housing without secondary valve bore, ▼▼ Housing for switch-over axis,
consumer port G 1/2 consumer port G 3/4 or G 1/2 consumer port G 3/4

Ordering code: Ordering code: Ordering code:


… A… A… … … Z Z … … ZUZ … Z Z …

… H… H… … … X X …

… Q Q …

125 125

83.5 98 125
49 46
47

B B
18

C
23
28

23
46
46

46
A A
30 30 30

MB MB MA
33

33

34
MA MA
13

13

19 19

Actuation

▼▼ Mechanical actuation only, spring-centered with tongue ▼▼ Mechanical actuation only with detent, tongue and lever

Ordering code: Ordering code:


… A Z … … B1 N …

A side B side A side B side

Ø8

280
8

45.5 41.5
52

78.5 128

Bosch Rexroth AG, RE 64276/04.2016


Control block | M4-12 41
Dimensions [mm]
Dimensions

▼▼ Mechanical/hydraulic actuation with cover with clamping piece ▼▼ Electrohydraulic actuation with standard cover
and hand lever (encapsulated), aluminum-free
Ordering code:
Ordering code:
… W. – …
… M B2 …
A side B side
… H B2 …

A side B side

26.9 23.9
"b"

107
56.5
"a"

b
Mb Ma

209
21.7 28.9
107

a
56.5

108 56.5

▼▼ Electrohydraulic actuation with check valve for hydraulic


superposition

64 157
Ordering code:
… G. – …

▼▼ Electronic pilot module EPM2 with hand lever (encapsulated) A side B side

Ordering code:
… C.A K …

61
147

26.9 23.9

A side B side "b"


107

169
56.5

"a"

21
Mb Ma
230
152

60

64
°

108

135 86
46

 RE 64276/04.2016, Bosch Rexroth AG


42 M4-12 | Control block Dimensions [mm]
Dimensions

End plates

▼▼ End plate LA ▼▼ End plate LZ

103
103
25
25

15
15

M10
M10

125
125
114.5
114.5
30 67
30 67
15 46.5 15 46.5

83.5
114

114
15
63

63

27
LSZ
15

17

15
▼▼ End plate LAPT ▼▼ End plate LZPT

103 103

25 25
15
15

M10 M10

125 125
114.5 114.5
50 67 50 67
15 46.5 15 46.5

T T

P
114

P
114

83.5
83.5

63
63

35
35

LSZ
27

87 37
15

87
15

Bosch Rexroth AG, RE 64276/04.2016


Control block | M4-12 43
Dimensions [mm]
Dimensions

▼▼ Diversion plate LU ▼▼ Diversion plate LU with two installation bores

123.5
45.5
103

20
25

M10
20

M10
106
12.5 47
18 28
8 16 17.5

33
33
T
114

50 C2
83.5

64

63
17

77

93.5

90
96

114
C1
P

83.5
35
15

46.5 Y
67
67 24

15
114.5
87.5 35
125
135
145

▼▼ End plate LA with two installation bores

123.5
45.5
20

M10
105
77
47
17.5 27 18
33

C2
33

T
50
64
64

75
88
84

C1
93.5

LSZ
114

P1
83.5

Y1

35 67
15

87.5
135
150

 RE 64276/04.2016, Bosch Rexroth AG


44 M4-12 | Control block Dimensions [mm]
Dimensions

Order examples

▼▼ Closed center control block with lateral inlet plate (as per order example on page 13)

429

230
"b"
152

LS
X Y
86.5

"a"
63

44.5
54
40
39

27
13
38.5
65
89
135 125 86

4 98

8 83.5 11 114
49
6 10
18

30
B2
28

46
A2
C 8
23

239
46
47
B1 3
23

46
4
A1 7
5
T 50 9
28

46 114 4
2
4

108 48 56.5
85
114.5
67
15

46.5
83.5

103

25

1 Name plate
12

2 Inlet plate J…Y


12 3 Directional valves
4 LA end plate
M 5 Control cover W (side A)
34

for electrohydraulic actuation


MB 6 Control cover CBA (side A) with
33

MA electronic pilot module (EPM2)


7 Control cover, standard (side B)
8 Control cover K (side B)
15

19
25 9 Stroke limiter
30 10 Secondary valves
72
11 Tie rod
103
12 Fastening thread 4 × M10; 15 deep

Bosch Rexroth AG, RE 64276/04.2016


Control block | M4-12 45
Dimensions [mm]
Dimensions

▼▼ Open center control block with lateral inlet plate (as per order example on page 14)

1
"b"
X M
86.5
"a"
63 LS

51.5

50
39

25
35
108 45 79
91.5
132
317
114 34
125 86
86.5
98 56.5
13 39
83.5 52
27
4 49

41.5 10 LSZ

13
46

50
7 T
B3

A
46
6 A3 11
9

AB
B2

23
46
257
A2
3 "a" "b"

AB
5

13.5
B1
8

46
A1
12

B
Ø8
26

Y
43

65
T
P

2 50 45 7 4
64 91.5 48 92
114 31.5
114.5
15

87
35
83.5

46.5 P

67

103
30 1 Name plate
25 2 Inlet plate P…Y
19
3 Directional valves
4 LZPT end plate
12

5 Control cover A (side A)


14
for mechanical actuation
6 Control cover H (side A)
for hydraulic actuation
33

7 Control cover W (side A)


for electrohydraulic actuation
30
13

20
8 Mechanical actuation only with
tongue (side B)
9 Control cover, standard (side B)
10 Control cover X (side B)
11 Stroke limiter
15

25 12 Secondary valves
103 13 Tie rod
14 Fastening thread 4 × M10; 15 deep

 RE 64276/04.2016, Bosch Rexroth AG


46 M4-12 | Control block Dimensions [mm]
Dimensions

▼▼ Closed center control block with central inlet plate (as per order example on page 15)

"b"
86.5

83.5
"a"
63

39

15
46.5
10 67
114.5
125

137
125
11 83.5 4 114
49 6
7 8.5 3
18

28

30
B2

15
46
A2
1 P

X
27

30
8
53

65
65

270
80

MP
T LS

Y
2 B1

A
46
A1

B
35
6
108 28.5
3 9
4 7
67.5
5 25
90.5 43
125 93
114
135 125 170
97 114.5 86
46.5
15
52.5

83.5

°
152

60

230

67

137
103
1 Name plate
25
8.5 2 Central inlet plate JZ
20

12 3 Directional valves
4 End plate LA
5 Diversion plate LU
34.5 6 Control cover W (side A) for
25

electrohydraulic actuation
7 Control cover CBA (side A) with
112.5
electronic pilot module (EPM2)
8 Control cover K (side B)
9 Stroke limiter
15

10 KBPS electro-proportional pressure


25 relief valve
103 11 Tie rod
12 Fastening thread 4 × M10; 15 deep

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 47
Dimensions

▼▼ Closed center control block with combination inlet plate (as per order example on page 16)

236
157.5

135 133

440

98

46

11 25 78 114

5 12
15

30
4

46
23
9
A3 B3
10

46
20
1
12

A2 B2

44
T
30

2 118
40
45

76
344

90
63

MP
75
LS
40
P X
22

51
A1 B1
3
25.5

7 8

50
35

6
18 20 25
106
48.5 40

85 47

93.5 130

28

48

113

141

125 64
1 Name plate
2 Central inlet plate JK
63

3 M4-15 directional valve


4 M4-12 directional valve
5 LA end plate
6 Diversion plate LU
7 Control cover CBA (side A) with
electronic pilot module (EPM2)
8 Control cover K (side B)
9 Control cover, standard (side B)
10 Stroke limiter
11 Tie rod
12 Fastening thread 4 × M10; 15 deep

 RE 64276/04.2016, Bosch Rexroth AG


48 M4-12 | Control block
Dimensions

▼▼ PM open center mono block (installation of further directional valves is not possible)

43
95
2

125
4

T 5

124
Y

98.5
72
33
P

3 15

18

1 72

78.5

94

50
41

A B
98

6
144.5
105.4 67

40
11

19
43
87.5

67
90.5

1 Name plate
119

2 Mono block PM
3 Control cover W (side A)
for electrohydraulic
actuation
4 Control cover, standard
(side B)
294.5
5 Stroke limiter
6 Fastening thread
3 × M10; 19 deep

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 49
 On-board electronics: Electronic pilot module (EPM)

On-board electronics: Electronic pilot module (EPM)

▼▼ Electronic pilot module EPM2 Features


Time functions (ramp functions), characteristic curve form
and increase can be configured or changed directly via the
CAN bus during the working cycle. Various diagnostic func-
tions monitor the correct functioning of the pilot module.
The following are monitored in the basic version:
▶▶ The correct receipt of a valid setpoint signal
▶▶ Stability of the connection to the transmitter
▶▶ Compliance with the defined limits of the supply voltage
▶▶ Function of the pilot valves (short circuit, cable break)

Malfunctions are displayed externally via a visible light-emit-


ting diode (LED) (1) displayed in the form of an error code
1 (flashing code) on the housing.
The CAN bus version transfers the error code in the pilot
module status telegram to the open loop control, which can
evaluate it.

▶▶ Low wiring costs with CAN wiring as a result of the


Function
(daisy-chain) assembly
The electronic pilot module provides the flow control on
▶▶ Low flow rate hysteresis through clocked output stages
M4-12 control block via a digital electrical signal.
with superimposed dither
The digital (CAN bus) input signal is converted into a pilot
▶▶ Processor-independent watchdog
pressure by the pilot module by means of two electrohy-
▶▶ Separate selectable time ramps for each valve output
draulic pressure reducing valves.
A and B, opening and closing
With the CAN bus control, a looping of the electrical connec-
▶▶ Separate changeable characteristic curves from linear to
tion via the second plug-in connection to the next pilot mod-
progressive sequence for A and B
ule is possible (daisy-chain wiring). The entire control block is
▶▶ Linear characteristic curve reduction in operation and
then connected via the 4-pin Bosch Compact 1 connector of
consequent linear reduction of total quantity
the first pilot module to the machine control.
▶▶ Selectable monitoring limits of the operating voltage
It is possible to connect further CAN bus devices to the
can be configured via CAN bus
output of the last pilot module (see also RE 64815‑B).
▶▶ Extensive parameterizability according to customer
requirements from the plant by Bosch Rexroth

Options
▶▶ Position sensor
▶▶ Measuring port

 RE 64276/04.2016, Bosch Rexroth AG


50 M4-12 | Control block
On-board electronics: Electronic pilot module (EPM)

Parameterization specifications ▼▼ Daisy-chain wiring, standard version


For the parameterization specifications form, see project
planning help 64815-02.
It is used for setting the electronic pilot module supplied
according to the customer's requirements.

CAN connector pin assignment B B


Connection via Bosch compact connector, coding 1.
When using the CAN control, a connection to the next
module or to another CAN participant is possible via the
second Bosch compact connector, coding 2.
A A
A A A A
▼▼ Pin assignment on the Bosch compact connector

4 3 2 1

2
UBat
CANlow
CANhigh
Gnd
3 2 1
1 2 3 4

▼▼ Daisy-chain wiring, compact version


1

1 Bosch compact, coding 1 (black)


2 Bosch compact, coding 2 (gray)

Notice B B
Connection cables and connectors are not included and
must be ordered separately (see “Accessories” on
page 51).
Rexroth guarantees the correct function of the device, as
A A
described in instruction manual 64815-B. Rexroth A A A A
assumes no liability for the safe operation of the machine
or system of which this device forms part.

All control blocks with EPM2 can be optionally equipped


with mounted daisy-chain wiring and terminal resistor
connector. Terminal resistor is mounted in the last section
of the block.
Recommended cable for connection to the machine
electronics: Material number: R917c02724

3 2 1

1 Open connector for connection to the machine electronics


2 Daisy-chain wiring
3 Connector with terminal resistor

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 51
Accessories

Accessories

Cables and connectors for EPM


Material number Type Description Length
Daisy-chain cable, standard version

R917c02581 Cable For connection of two pilot modules (standard) 190 mm


R917c02599 Cable For connection of two pilot modules 240 mm
R917c02628 Cable For connection of two pilot modules via central inlet 370 mm

Daisy-chain cable, compact version

R917c05332 Cable With two connectors, coding 1 (black) 90°

R917c05333 Cable With two connectors, coding 2 (gray) 90°

Connection cable

R917c02724 Cable With one connector, coding 1 (black) 4000 mm


R917c04484 Cable With one connector, coding 2 (gray) 4000 mm

Connector and connector sets

R917c05459 Connector Coding 1 (black), dummy connector


R917c02627 Connector Coding 2 (gray), dummy connector

R917c05458 Connector Coding 1 (black), dummy connector with integrated terminal resistor

R900785606 Connector set Bosch compact, coding 1 (black)

R900785607 Connector set Bosch compact, coding 2 (gray)

 RE 64276/04.2016, Bosch Rexroth AG


52 M4-12 | Control block
On-board electronics: Electronic pilot module (EPM)

Plug-in connector for FTDRE… and FTWE…

Recommended plug-in connector 1 and 3 Junior Timer, Recommended plug-in connector 8 and 9 DT04
2-pin (AMP) (DEUTSCH)
▶▶ Material number: R900313533 ▶▶ Material number: R900733451
–– For conductor cross section from 0.5 to 1 mm² and –– For conductor cross section from 1.3 to 2.08 mm²
for an insulation diameter of the individual seals from and for an insulation diameter of the individual seals
1.2 to 2.1 mm from 1.35 to 3.05 mm
▶▶ Material number: R901022127 ▶▶ Material number: R901017847
–– For conductor cross section from 0.5 to 1 mm² and –– For conductor cross section from 0.83 to 1.3 mm²
for an insulation diameter of the individual seals from and for an insulation diameter of the individual seals
2.2 to 3 mm from 1.35 to 3.05 mm

▼▼ Recommended plug-in connector for Junior Timer, 2-pin (AMP) ▼▼ Recommended plug-in connector for DT04 (DEUTSCH)

Bosch Rexroth AG, RE 64276/04.2016


 Control block | M4-12 53
 M4 configurator

M4 configurator

The M4 configurator is available online. It helps to efficiently


utilize the flexibility and versatility of the valve right from the
design and engineering phase for new machines. This user-
friendly and intuitive program asks systematic questions
about the specific requirements for the system. It then
assembles the corresponding control block from individual
components. Technical data sheets, parts lists, schematics,
and both 2D and 3D information are instantly available and
speed up the development process for the machine.
The M4 configurator is linked to the Bosch Rexroth eShop.
The order of the configured control block can be placed
immediately.
Link: www.boschrexroth.com/m4-configurator

 RE 64276/04.2016, Bosch Rexroth AG


54 M4-12 | Control block
Related documents

Related documents

Title Document number Document type


Control blocks for mobile applications 64025-B Instruction manual
Load-sensing control block M4-12 64276-E Spare parts list
Load-sensing control block M4-12 64276-01-R Repair manual
Load-sensing control block M4-12 for explosive areas 64276-01-B Instruction manual
Electronic pilot module EPM2 64815-B Instruction manual
Ordering information for electronic pilot module EPM2 64815-02 Project planning help
Spool position sensor PSM for control blocks for mobile applications 95190 Data sheet
Hydraulic pilot controllers 2TH6 64552 Data sheet
Hydraulic pilot controllers 4TH5, 4TH6, 4TH6N 64555 Data sheet
Directional spool valve FTWE2K 58007 Data sheet
Directional spool valve FTWE4K 58008 Data sheet
Proportional pressure reducing valve FTDRE2K 58032 Data sheet
Proportional pressure reducing valve FTDRE4K 58038 Data sheet
Analog amplifier RA 95230 Data sheet
BODAS series 20 RC controller 95200 Data sheet
2/2-way spool valve KKDE 18136-08 Data sheet
3/2-way spool valve KKDE 18136-09 Data sheet
Proportional pressure relief valve, increasing characteristic 18139-04 Data sheet
curve KBPS.8A
Proportional pressure relief valve, decreasing characteristic 18139-05 Data sheet
curve KBPS.8B
2-way logic element MH2DAD 64586 Data sheet
Load-sensing control block SP-08 64139 Data sheet
Hydraulic fluids based on mineral oils and related hydrocarbons 90220 Data sheet
Environmentally acceptable hydraulic fluids 90221 Data sheet

Bosch Rexroth AG © Bosch Rexroth AG 2016. All rights reserved, also regarding any disposal,
Mobile Applications exploitation, reproduction, editing, distribution, as well as in the event of
Zum Eisengießer applications for industrial property rights. The data specified within only
97816 Lohr am Main, Germany serves to describe the product. No statements concerning a certain condition
Phone +49 9352 18-0 or suitability for a certain application can be derived from our information.
info.ma@boschrexroth.de The information given does not release the user from the obligation of own
www.boschrexroth.com judgment and verification. It must be remembered that our products are
subject to a natural process of wear and aging.

Bosch Rexroth AG, RE 64276/04.2016