Plumbing Notes:: Legend

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SEPTIC TANK

0.15 1.50 0.15


3.70

0.80 0.15 0.80 0.15


PLUMBING NOTES:
CO

F.D. F.D. C L O S E T

* ALL PLUMBING WORKS SHALL STRICTLY FOLLOW

0.15
W.C.
WC
BEDROOM 5
F.D.
T&B THE NATIONAL PLUMBING CODE OF THE
W.C. C L O S E T

MANHOLE MANHOLE MANHOLE PHILIPPINES AS PER P.D. 1096 OF N.B.C.

0.50
1.30

1.00
C L O S E T C L O S E T

BEDROOM 2 BEDROOM 4

C L O S E T C L O S E T

* SLOPE:

0.15
2% FOR HORIZONTAL OR WASTE PIPES
C L O S E T C L O S E T

BEDROOM 1 BEDROOM 3
12mm REINF. BARS @ .0m O.C. B.W. 0.50 1% FOR HORIZONTAL VENT

0.15
C L O S E T C L O S E T

PLAN
1½% FOR STORM DRAIN LINES
K.S. LIVING AREA
KITCHEN
CO

NGL
INLET min. 100mm Ø PVC PIPE scum min. 100mm Ø PVC PIPE
min. 100mm Ø PVC PIPE
* PROVIDE CONTROL VALUE FOR EVERY TOILET
water line

ROOM

0.30
water line

0.30
min. 0.20m

Min. 1.20m/Max. 1.80m liquid depth


PORCH

More than 0.15m less than 0.30m


10mm HOR. BARS @ EVERY

D S A N I T A R Y L A Y- O U T P L A N SEDIMENTATION DIGESTION LEACHING


3 LAYER 10mm VERT. BARS
@ 0.40m O.C.
* PLUMBING WORKS MUST BE PROPERLY TESTED
A 2 SCALE 1:100 MTS.
CHAMBER CHAMBER CHAMBER
4" CHB AND APPROVED BY PROPER AUTHORITIES BEFOR
Min. of 2m³ (12 to 2 3 of total volume) COVERING
Min. of 1m³
(Max. of 13 of total volume)

0.15
* ALL P.V.C. PIPES AND FITTINGS SHALL BE OF
12mm REINF. BARS @ .0m O.C. B.W.
STANDARD SIZES AND SERVICE WEIGHT
W.C. W.C. C L O S E T

SECTION
BEDROOM 5 Note: ST is rectangular in shape

W.C.
T&B
C L O S E T
ST with the length of more than 3.7m shall have
additional manhole * SEPTIC VAULT CONSTRUCTION SHALL STRICTLY
Note: Minimum of two compartments
C L O S E T C L O S E T
Tank capacity: more than 2.8m³, Detention time 3 days
Note: ST with over 6m³ capacity:
FOLLOW SECTION 233 OF THE NATIONAL
Second compartment shall be less than 1.5m length
BEDROOM 2 BEDROOM 4
PLUMBING CODE
SEPTIC TANK DETAIL
L I N E

C L O S E T C L O S E T

SCALE : 1 : 25 MTS
C L O S E T C L O S E T

BEDROOM 1 BEDROOM 3
* DIMENSIONS OF THE SEPTIC VAULT TO BE USED:
LENGTH L 3.40m.
W A T E R

LEGEND:
C L O S E T C L O S E T

WIDTH W 1.10m.
K.S.
LIVING AREA
KITCHEN
HEIGTH H 1.20m.

W.C. - WATER CLOSET


CV
PORCH
S.T. - SEPTIC TANK
WM

LAV. - LAVATORY
TO WATER SOURCE
C.O. - CLEAN OUT
W A T E R L I N E L A Y- O U T P L A N
F.D. - FLOOR DRAIN
D
A 2 SCALE 1:100 MTS. V.T.R. - VENT THRU ROOF
K.S. - KITCHEN SINK

MASTER PLUMBER : TITLE OF PROJECT : APPROVED AS TO PLAN & LOCATION : R.A. 9266, ARTICLE IV, SECTION 33: SHEET CONTENTS SHEET NUMBER
D R A W I N G S A N D S P EC I F I C A T I O N S A N D O T H ER
CONTRACT DOCUMENTS DULY SIGNED, STAMPED,
OR SEALED, AS INSTRUMENTS OF SERVICE, ARE PLUMBING PLAN
THE INTELLECTUAL PROPERTY AND DOCUMENTS OF
THE ARCHITECT, WHETHER THE OBJECT FOR WHICH
"PROPOSED ONE-STOREY RESIDENTIAL BLDG." RICKY BALILI MAIINIT THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE P 1
PRC REG. NO. DATE ISSUED: O W N E R
UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO
MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE
RE PET IT ION O F A N FO R OT H ER PR OJ EC TS OR 1
PTR NO. DATE ISSUED: BUILDINGS, WHETHER EXECUTED PARTLY OR IN
WH O LE , W IT H O U T T H E WR IT T E N C O N SEN T OF
PLACE ISSUED : T I N: LOCATION: TANGNAN, PANGLAO, BOHOL ADDRESS: BAANG, CATIGBIAN, BOHOL ARC HITECT OR AUTHOR OF SAID DOCUM ENTS.