Hkkjr ljdkj

GOVERNMENT OF INDIA

dsUnzh; yksd fuekZ.k foHkkx


CENTRAL PWD

dqjlh {ks= njsa


PLINTH AREA RATES
(1.10.2012)

fuekZ.k egkfuns”kd] ds-yks-fu-fo-] ubZ fnYyh ds izkf/kdkj ls izdkf”kr


Published under the Authority of Director General, CPWD, New Delhi

eqfnzr ,oa foif.kr% eSllZ tSu cqd ,tsalh] lh&‹] dukWV Iysl] ubZ fnYyh& ƒƒ000ƒ
Printed & Marketed by: M/S JAIN BOOK AGENCY, C-9, Connaught Place, New Delhi- 110001
© All rights reserved. No part of this publication, either in English or in Hindi, may be reproduced in any form
or by any means, electronic or mechanical, including photocopy, recording or any information storage and
retrieval system, without permission, in writing, from the Director General, CPWD, New Delhi.
This PAR-2012 is prepared for the use of CPWD. However, this may be used by other Government departments,
PSUs, private bodies & individuals also at their own discretion. CPWD shall not be responsible for any ambiguity,
discrepancy, dispute or financial loss, arising directly or indirectly by using or following items of PAR-2012 by
such Govt. departments, PSUs, private bodies or individuals.
A GOVERNMENT OF INDIA PUBLICATION
Published by
DIRECTOR GENERAL (WORKS)
CPWD, NIRMAN BHAWAN, NEW DELHI-110 011
Printed & Marketed by
JAIN BOOK AGENCY
Authorised Dealers of Govt. Publications
C-9, Connaught Place, New Delhi-110001
Phone : 44556677 Fax : 41513850
E-mail : sales@jainbookagency.com
Website : www.jainbookagency.com
Distributed by
JBA DISTRIBUTORS
N-67, First Floor, Munshiram Building,
Connaught Place, New Delhi-110001
Phones : 23354824, 43528601
E-mail : sales@jba.in
Website : www.jba.in

JAIN BOOK AGENCY (SOUTHEND) JAIN BOOK AGENCY (CENTRAL)


1, Aurobindo Place Market, 5061/1, Sant Nagar, Karol Bagh,
Hauz Khas, New Delhi-110016 New Delhi - 110005
Phone : 26567066, 26566113,41755666 Phone : 44332211
E-mail : sales@jainbookagency.com
Website : www.jainbookagency.com

JAIN BOOK AGENCY (GREATER NOIDA) JAIN BOOK AGENCY (GURGAON)


11 Jagat farm Complex 12, Central Plaza Mall, Sector 53,
Gama Sector Market Golf Course Road,
Near OBC Bank Gurgaon 122002, Haryana
Greater Noida Phone : 0124- 4143020, 4142665
Phone : 0120- 4206655, 4206657 Mobile 9810666810

DIAL-A-BOOK
( 011-4175 8700
Books will be delivered next day by COURIER
(Payment to courier-boy)
in Delhi, Noida, Ghaziabad, Faridabad & Gurgaon
(nominal courier charges extra)
Also available at
All Leading Booksellers & Authorised Govt. Dealers In India

Price : Rs. 100/- (excluding postage and forwarding charges etc.)


FOREWORD TO PAR 2012

Plinth Area Rates w.e.f. 1/10/2007(Reprint) published in 2010 by CPWD is a very useful
document for preparation of Preliminary Estimates for all Govt. residential buildings and non-
residential buildings e.g. Offices/ Colleges/ Hospitals, Schools, Hostels etc. which is in extensive
use by all Central Government Departments, Public Sector Undertakings, Private Sector Builders
and Engineers etc.
The rates adopted in the PAR are based on detailed analysis of actual cost of construction
of buildings of various types in different parts of the country and provide a realistic basis for
assessment of approximate cost of new proposed buildings.
I am sure that this PAR -2012 will be very useful to all concerned.

New Delhi ( Rakesh Misra )


Dec. 2012 Director General
Govt. of India
Central Public Works Department
(Technology Application and Standards Unit )
Nirman Bhawan, New Delhi
No: 62/SE(TAS)/Plinth Area Rates/399 Dated : 24/12/2012

MEMORANDUM
Plinth Area Rates as applicable on 1.10.2007(Reprint) were last circulated under Memo no.
SE(S&S)/EE-II/AE-III/ dated 19.7.2010 along with annexure I to IV. Relevant cost indices with reference
to base 100 as 1.10.2007 shall continue to be applicable on these plinth area rates for works in
progress etc.
However, the need for issuing fresh plinth area rates has been felt to account for rise in prices
in the last 5 years as well as the latest development in construction practices such as fire safety
measures for high rise buildings and also incorporating the green buildings concept for three star
rating of GRIHA.
Accordingly, fresh plinth area rates with reference to base 100 as on 1.10.2012 has been
prepared for circulation in the department. In future, Preliminary Estimates may be prepared on the
basis of these plinth area rates.
All the rates are based on data of actual expenditure for structures completed recently, as
received from various field formations. In case of any discrepancy in Hindi & English versions,
English version will prevail.
The latest plinth area rates as on 1.10.2012 is hereby issued with following annexures :
Annexure – I : Fresh Plinth Area Rates with base 100, as on 1.10.2012 (for residential /non
residential buildings, services and development ) .
Annexure – II : Broad specifications and scale of amenities for sanitary/Electrical fittings for
which plinth area rates are applicable.
Annexure – III : Memo no. 29/21/58/WI of 10/83 indicating the rules for working out plinth
area from plans, to be observed while adopting these plinth area rates given in
Annexure - I.
Annexure –IV : Proforma for calculating cost index for future cost index with base 100 as
on 1.10.2012 indicating revised weightages also.
Annexure –V : Specifications for buildings - Non Residential & Residential Buildings.

Encl: Annexure I to V Director General


CPWD, Nirman Bhawan,
New Delhi
PLINTH AREA RATES 3

PLINTH AREA RATES AS ON 01.10.2012


ANNEXURE – 1

S. No. Description Office/College/Hospital Schools Hostels Residential


1 2 3 4 5 6

1.0 (A) RCC FRAMED STRUCTURE Rates in Rs. per sq. metre
( Specifications as per Annexure –II)

1.1(A) RCC framed structure upto six storeys

1.1.1(A) Floor ht. 3.35 mtr. 23500 17000

1.1.2 (A) Floor ht. 2.90 mtr. 16500 16000

1.0 (B) RCC FRAMED STRUCTURE


(Normal Buildings)
(Specifications as per Annexure –V)
1.1 (B) RCC framed structure upto six storeys
1.1.1(B) Floor ht. 3.35 mtr. 19000 15200
1.1.2 (B) Floor ht. 2.90 mtr. 15000 14500

1.2 EXTRAS FOR

1.2.1 Every additional storey over six storeys 560 560 560 560
upto nine storeys

1.2.2 Every additional storey over nine 580 580 580 580
storeys upto twelve storeys

1.2.3 Every 0.3 mt. additional height of floor 270 270 270 270
above normal floor height of 3.35 mt./
2.90 mts.

1.2.4 Every 0.3 mt. higher plinth over normal 270 270 270 270
plinth height of 0.6 mt. (on G.F. area
only )

1.2.5 Every 0.30 mt. deeper foundations 270 270 270 270
over normal depth of 1.20 metre
(on G.F. area only )

1.2.6 Making stronger foundations to take 2270 2270 2270 2270


load of one additional floor at a later
date (on area of additional floor only )

1.2.7 Strip foundations in poor soil having 520 520 520 520
bearing capacity less than 10 tonnes/
sqmt. (on G.F. area only)

1.2.8 Resisting Earthquake forces 1140 1140 1140 1140

1.2.9 R.C.C. Raft foundations 6450 6450 6450 6450


(ground floor only )
4 PLINTH AREA RATES

1.2.10 Pile foundation up to a depth of 15 mts 11750 11750 11750 11750


(on ground floor area only.)

1.2.11 Stronger structural members to take


heavy load above 500 Kgs./sqm.
upto 1000 Kgs./Sqm. 1500 1500 1500 1500

1.2.12 Larger modules over 35 sqm. 1500 1500 1500 1500

1.3 BASEMENT FLOOR

1.3.1 Floor ht. 3.35 mtrs with normal water


proofing. 19000 - - -

1.3.2 EXTRA FOR BASEMENT WITH

1.3.2.1 Every 0.3 mt. addl. Height


(above 3.35 mt. ) 2320 - - -

1.3.2.2 Reduction for every 0.5 m. less height


of basement than normal height 3.35 mt. (- 1280) - - -

1.4 FIRE FIGHTING

1.4.1 With wet riser system 500 500 500 500

1.4.2 With sprinkler system 750 750 750 750*

1.5 FIRE ALARM SYSTEM

1.5.1 Manual Fire Alarm System - - - 300

1.5.2 Automatic Fire Alarm System 500 500 500 500*

1.6 Operation Theatre (OPD)


(Extra provision ) 2150 - - -
1.7 Pressurized mechanical ventilation
system in the basements (with supply
of Exhaust blowers) 650 650 650 650
1.8 STILT PORTION
1.8.1 Stilt Portion of Multistorey RCC structure
(up to ht of 3.35m) Applicable area only 9850 9850 9850 9850
1.8.2 Every 0.30 mt additional height (above 3.35m) 450 450 450 450

Note :- Rates marked as*under items 1.4.2 & 1.5.2 for residential building are NBC 2005 applicable for apartment houses more
than 45m height.
PLINTH AREA RATES 5

Sl. No. Description Non -Residential Residential


Office/College Schools Hostel Type-I, II, III Type –IV Type –V,
/Hospitals & servant Qtrs. VI and
Qtrs. above
1 2 3 4 5 6 7 8
2.0 LOAD BEARING
CONSTRUCTION
2.1 Floor height 3.35 mt.
2.1.1 Single storeyed 15000 14000 - - - -
2.1.2 Doubled storeyed 14300 12200 - - - -
2.1.3 Three storeyed 15000 14000 - - - -
2.1.4 Four storeyed 16000 14000 - - - -
2.2 Floor height 2.90 mt.
2.2.1 Single storeyed - - 13300 11600 12800 14000
2.2.2 Double storeyed - - 11700 11300 12400 13100
2.2.3 Three storeyed - - 13300 11600 12800 13400
2.2.4 Four storeyed - - 14000 12200 13500 14300
2.3 Scooter & Cycles sheds - - - 10500 10500 10500
2.4 Garrages - - - 10000 10000 10000
2.5 Extra for
2.5.1 Every 0.3 mt. additional height
above normal height
3.35 mt./2.90 mt. 270 270 270 270 270 270
2.5.2 Every 0.3 mt. higher plinth over
normal plinth height of 0.60 mt.
(on ground floor area only ) 270 270 270 270 270 270
2.5.3 Every 0.3 mt. deeper foundations
over normal depth of 1.20 mt.
(on G.F. area only) 270 270 270 270 270 270
2.5.4 Making stronger foundations to
take load of one additional floor
at a later date (on area of
additional floor only ) 780 780 780 780 780 780
2.5.5 Foundations on poor soils having
bearing capacity less
than 10 T/sqmt. 520 520 520 520 520 520
2.5.6 Foundation on poor soils requiring
under reamed pile 6 mt. long 5600 5600 5600 5600 5600 5600
2.5.7 R.C.C. Raft foundation
(G.F. area only) 6450 6450 6450 6450 6450 6450
2.5.8 Pile foundation up to a depth
of 15 mtr. (G. F. area only) 11750 11750 11750 11750 11750 11750
2.6 Extra for resisting Earth-quake
Forces
2.6.1 In Zone V 1050 1050 1050 1050 1050 1050
6 PLINTH AREA RATES

Sl. No. Description Non -Residential Residential


Office/College Schools Hostel Type-I, II, III Type –IV Type –V,
/Hospitals & servant Qtrs. VI and
Qtrs. above
1 2 3 4 5 6 7 8

2.6.2 Buildings of two storeyes or


more in Zone III & IV 520 520 520 520 520 520
2.6.3 Resisting earthquake forces in
Zone II and single storey buildings
in Zone III & IV
2.7 Stronger structural members to
take heavy loads above
500 Kg /sqm. Up to
1000 Kg/sqmt. 1500 1500 1500 1500 1500 1500
2.8 Larger modules over 35 sqmt. 1800 1800 1800 1800 1800 1800
2.9 Fire-fighting
2.9.1 With wet riser system 500 500 500 500 500 500
2.9.2 With sprinkler system 750 750 750 750 750 750
2.10 Fire Alarm System
2.10.1 a) Manual Fire Alarm system - - - 270 270 270
2.10.2 b) Automatic Fire Alarm system 500 500 500 - - -
2.11 O.P.D. Operation Theatre etc. 2150 - - - - -

Note : Rates for items are applicable on entire plinth area except for items 1.2.4, 1.2.5, 1.2.6, 1.2.7, 1.2.9,1.2.10,1.5, 1.6, 1.7, 1.8,
2.5.2, 2.5.3, 2.5.4, 2.5.5, 2.5.6, 2.5.7, 2.5.8, 2.8, 2.9, 2.10, and 2.11.
PLINTH AREA RATES 7

S. No. Description Office & Hospitals Schools Hostels Type of Quarters


College I II III IV V,VI &
above
1 2 3 4 5 6 7 8 9 10 11
3.0 SERVICES.
3.1 Internal water supply & 4% 10% 5% 15% with 12% 12% 12% 12% 12%
sanitary installations attached
toilets, 10%
% age means % age of building
with
cost of normal Building (1.0B)
common
toilets.
3.2 External service connections 5% 5% 5% 5% 5% 5% 5% 5% 5%
3.3 Internal electric 12 ½% 12 ½% 12½% 12½% 12½% 12½% 12½% 12½% 12½%
installations
Note : The above does not include
service connection charges &
electrification
3.4 Internal electric - - 15% of - - - - - -
installations for laboratories building
of schools cost
of
normal
building
(1.0B)
3.5 Internal electric 15% of - - - - - - - -
installations for terminal building
building and other allied cost
structures in airports
3.6 Extra for :
3.6.1 Power wiring and plugs 4% 4% - - - - - - -
3.6.2 Central Call bell system 1% - - - - - - - -
3.6.3 Lightening conductors
3.6.3.1 Upto 4 storeyed building 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
3.6.3.2 5 to 8 storeys buildings 0.33% 0.33% 0.33% 0.33% 0.33% 0.33% 0.33% 0.33% 0.33%
3.6.3.3 Beyond 8 storeyed 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25%
buildings
3.6.4 Telephone conduits 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
3.6.5. Centralized Intercom system - - - - 1% 1% 1% 1% 1%
3.6.6 Computer conduiting 0.5% 0.5% 0.5% 0.5%
3.6.7 Quality assurance 1% 1% 1% 1% 1% 1% 1% 1% 1%

Note :- Quality control charge of 1% should be taken in estimate only when client department request for TPI.
8 PLINTH AREA RATES

Sl. No. Type of lift Capacity/ Weight Speed in Travel Doors Control Price Addl. Price
Persons M/Sec. (Rs. In lacs) for each
additional
floor (Rs. )
1 2 3 4 5 6 7 8 9 10
4.0 LIFTS
4.1 Passenger lifts
4.1.1 Passenger lift 8 544 Kg. 1.0 G+4 Power ACV 18.00 1,25,000.00
operated VVF
4.1.2 Passenger lift 8 544 Kg. 1.5 G+5 Power ACV 24.00 1,25,000.00
operated VVF
4.1.3 Passenger lift 13 884 Kg. 1.0 G+4 Power ACV 22.00 1,25,000.00
operated VVF
4.1.4 Passenger lift 13 884 Kg. 1.5 G+5 Power ACV 28.00 1,25,000.00
operated VVF
4.1.5 Passenger lift 16 1088 Kg. 1.0 G+4 Power ACV 28.00 1,50,000.00
operated VVF
4.1.6 Passenger lift 16 1088 Kg. 1.5 G+5 Power ACV 34.00 1,50,000.00
operated VVF
4.1.7 Passenger lift 16 1088 Kg. 2.5 G+12 Power ACV 70.00 1,50,000.00
operated VVF
4.1.8 Passenger lift 20 1360 Kg. 0.75 G+4 Power ACV 24.00 1,50,000.00
(Bed lift) operated VVF
4.1.9 Passenger lift 20 1360 Kg. 1.5 G+5 Power ACV 32.00 1,50,000.00
operated VVF
4.1.10 Passenger lift 20 1360 Kg. 2.5 G+12 Power ACV 75.00 1,50,000.00
operated VVF
4.2 Goods lifts
(2 speed )
4.2.1 1 Ton - 0.5 G+4 26.00 85,000.00
4.2.2 2 Ton - 0.5 G+4 33.00 85,000.00
4.2.3 3 Ton - 0.25 G+4 41.00 1,00,000.00

Note:- 1. ACVVVF= AC variable voltage variable frequency.


2. Provision for lift may also be taken for the buildings having floor less than G+ 4.

Sl. No. Description Rates in Rupees


5 WATER TANK (RCC ONLY )
5.1 Overhead tank without independent staging 15 / Litre.
5.2 Overhead tank upto staging height 20 metres 25/ Litre.
5.3 Overhead tank with staging height between 20 metres and upto 30 metres 30/ Litre.
5.4 Overhead tank with staging height between 30 metres and 40 metres 35/ Litre.
5.5 Underground sump 15 / Litre
PLINTH AREA RATES 9

Sl. No. Description Rates in Rupees


6 DEVELOPMENT OF SITE
6.1 Levellling 95/ sqm.
6.2 Internal roads & paths 145/ sqm
6.3 Sewer 110/ sqm.
6.4 Filter Water Supply
6.4.1 Distribution lines 100 mm dia and below 80/ sqm.
6.4.2 Peripheral grid 150 mm to 300 mm dia pipes 60/ sqm.
6.4.3 Unfiltered water supply distribution lines 45/ sqm.
6.5 Storm water drains 85/ sqm.
6.6 Horticulture Operations 80/ sqm.
6.7 Street lighting
6.7.1 With fluorescent lamps 95/ sqm.
6.7.2 With HPMV Lamps 130/ sqm.
6.7.3 With HPSV Lamps 165/ sqm.
6.7.4 Exit sign board i/c electric signage. 85/ sqm.

Note :-
(1) The rates are per sqm. and are to be applied on the entire areas of the plinth/ plot to be developed.
(2) These rates will apply to normal conditions and normal layout plans. If any extras are required due to nature of layout involving filling,
cutting or bringing services, from large distances, then additional provision should be made.
(3) Cost of bulk services water supply, sewage disposal e.g.
(a) Tube wells, pumps, open wells, treatment plant, extension of lines from source of local bodies, head works at water source etc.
(b) Sewage pumps, sewage treatment plants, septic tanks, extension of cut-fall sewer up to point of disposal etc. are not included in
these rates. Extra provision depending upon site conditions may be made for these.
(4) Cost of HT sub - station equipments, LT distribution system, DG sets, pumps, air-conditioning and other specialized works like
aesthetic external lighting with metal halide lamp & facade lighting, addressable fire alarm system, rising mains, UPS, aviation obstruction
lights, external service connections, storage water cooler, IBMS, CCTV, access control system for security, solar water heating system,
solar lighting etc. are not included in above rates and the same are to be taken as per actual based on functional / utility of the proposed
building.
(5) 1.0 (A) shall be adopted for GPO and GPRA.
1.0 (B) may be adopted for other buildings.
(6) The green measures considered for Civil & Electrical works
(a) Over deck insulation and Application of high SRI reflective paint on the roof.
(b) Masonry work in super structure with Autoclave Aerated Concrete (AAC) blocks/ fly ash bricks.
(c) Window with reflective glass coating / High performance double glazed unit.
(d) Paints with low VOC options.
(e) Rain water harvesting.
(f) Replacement of conventional pillar cock with pillar cock having infrared sensor and foam flow technology (in offices and
Hospitals).
(g) AC plant with VVVF drives and ECBC complaint chillers, high efficiency motors, plant optimizers etc. (cost of plant not
included.)
(h) Automated lighting controls with day light sensors and PIRs etc.

( R.K. Saraswat ) (Mathura Prasad) (V. K. Rokde)


Executive Engineer (TAS)-I Superintending Engineer (TAS) Chief Engineer (CSQ)
CPWD, Nirman Bhawan, CPWD, Nirman Bhawan, CPWD, Nirman Bhawan
New Delhi New Delhi
10 PLINTH AREA RATES

ANNEXURE - II
SPECIFICATIONS FOR RESIDENTIAL BUILDINGS
Item no. Item Type I, II, III & Servant Qtrs. Type –IV Type –V/VI Hostel
1.1 Foundation Bearing capacity 10 tonnes per sq. metre.
Applicable to all
1.2 Type –spread foundation in RCC isolated
/combined, continuous wall footing with
lean concrete.
1.3 Depth upto 1.2 metres below ground level
2.1 Super structure RCC framed construction with filler walls
in brick work or load bearing construction
if brick/stone masonry with intermediate
columns where found necessary.
2.2 Internal partition- half brick masonry in
cement mortar 1:4

S No. Item Type I, II, III & Servant Qrs. Type IV Type V and VI
3.1 Frames
3.1.1 Window Pressed steel frames made out of Pressed steel frames made Same as Type IV
corrosion resistant coated sheet out of corrosion resistant
of 1.6 mm thick with double rebate coated sheet of 1.6 mm thick
with double rebate/scratch
proof aluminium sheets/poly-
propylene windows
3.1.2 Door T-Iron /Pressed steel/Pre-cast R.C.C. Pressed steel frames made Same as Type IV
frames. out of corrosion resistant
coated sheet of 1.6 mm thick
with single rebate/factory
manufactured precast RCC
frames.
3.2 Shutters
3.2.1 Window M.S. tubular box section corrosion M.S. tubular box section Same as Type IV
resistant coated shutters. Wire mesh corrosion resistant coated
shutters may also be provided at the shutters. Wire mesh shutters
discretion of Zonal Chief Engineer. may also be provided at the
discretion of Zonal Chief
Engineer /Scratch proof
aluminium window. Shutters
to match with frame.
3.2.2 Main Door Double door, one with iron grill with Same as Type 1 to III. Same as Type I to III
wire mesh mosquito proof and other except that panelling
35 mm thick panelled shutter with will be of both side
hard wood style and rail with decorative,
panelling of pre-laminated particle pre-laminated particle
board, one side decorative other side board.
balancing.
3.2.3 W.C / Bath Solid PVC shutters 28 mm thick Same as Type I to III Same as Type I to III
room
3.2.4 Kitchen Partly panelled and partly wire mesh Same as Type I to III Partly panelled and
door with stainless steel wire mesh. The partly wire mesh with
panelling with pre-laminated particle stainless steel wire mesh.
board, one side decorative-35 mm The panelling with pre-
thick panelled shutter with hard wood laminated particle board,
style and rails. both sides decorative-
35 mm thick panelled
shutter with hard wood
styleand rails.
PLINTH AREA RATES 11

S No. Item Type I, II, III & Servant Qrs. Type IV Type V and VI
3.2.5 Other doors 35 mm thick panelled shutters with hard Same as Type I to III 35 mm thick panelled
wood style and rail with panelling of pre- shutters with hard wood
laminated board, one side decorative. style and rail with
panelling of pre
laminated board, both
sides decorative.
3.3 Fittings Powder coated M.S. fittings/stainless Powder coated aluminium/ Same as type IV
steel fittings stainless steel fittings
3.4 Peep hole and
security chain
for external
door only. Yes Yes Yes

Note : 1. In item no. 3 of Wood work, if any other option of local material is available, the same can also be used by the
respective Chief Engineers.
2. External sliding door bolt and handles will be in powder coated M.S. or stainless steel.
3. Koba treatment on roofing in all type of quarters.
S No. Item Type I, II, III & Servant Qrs. Type IV Type V and VI
4 Flooring
4.1 Bedrooms/ Grey/Beige color ceramic floor tiles Same as Type 1 to III Grey/Beige color rectified
living rooms (size 12** × 12** Matt finish) of ceramic floor tiles (size
approved design 16** × 16** Matt finish)
of approved design.
4.2 Kitchen, Ceramic floor tiles (size 12** × 12** Same as Type 1 to III Rectified ceramic floor tiles
internal Matt finish) of approved design. (size 16** × 16** Matt finish)
circulation area of approved design.
4.3 Common (i) Kota stone flooring and matching Same as type I to III Same as type IV
circulation skirting. In staircase, single piece
area, staircase pre-polished kota stone slab with
pre-finished nosing be used.
(ii) Dado of ceramic tile light grey/
dull green shade 12** × 12** size upto
120 cm ht. above skirting i/c green
marble nosing.
4.4 Kitchen work Green marble pre-polished with Same as type I to III Granite with pre-polished
top pre-moulded nosing and premoulded nosing
4.5 Toilets Ceramic floor tiles (Size 12** × 12**) Matt Same as type I to III Rectified ceramic floor tiles
finish/anti skid of approved design. (size 16** × 16**)Matt finish/
anti skid of approved design
4.6 Skirting/Dado Ceramic white glazed tiles (min. size Same as type I to III Ceramic white giazed tiles
in toilets 8** × 12**½ upto door lintel level. (min. size 8**** × 12***½ upto
ceiling ht. with decorative
band of tiles.
5.0 Finishing Acrylic smooth exterior finish or Premium Acrylic smooth Premium Acrylic smooth
5.1 External washed stone grit plaster or exterior finish with additive exterior finish with additives
exposed brick work of silicone or washed mosaic of silicone or washed mosaic
plaster in ordinary cement plaster in ordinary cement
or exposed brick work or exposed brick work.
5.2 Internal All walls and ceilings to be treated Same as type I to III All walls and ceilings to be
with the 2 mm thick POP followed treated with the 2 mm thick
with a coat of acrylic/ oil bound POP followed by plastic
distemper except ceiling which will emulsion paint except
be done with white wash. Synthetic ceiling which will be done
enamel paint on all wood work and with white wash. Synthetic
steel work. enamel paint on all wood
work and steel work.
12 PLINTH AREA RATES

SCALE OF AMENITIES FOR GENERAL POOL ACCOMMODATION


Item Item Type I Type II Type III Type IV Type V/VI
No.
1 Kitchen
(i) Shelves in tiers not more Yes Yes Yes Covered cup boards Same as Type IV
than 400mm wide along above sill level with pre-
one wall laminated decorative
1 " thick board.
(ii) Kitchen sink Stainless Same as Same as Stainless steel sink with Same as type
steel sink type -I type - I drain board -IV/vitreous
without drain china sink with
board draining board
(iii) Dado Ceramic glazed tiles Yes Yes Yes Yes Ceramic glazed
(size 8** × 12**) for 60cm. tiles (size
above and along work top 8** × 12**) 60cm
and around and below high dado from
kitchen sink skirting level
upto 60cm/-ht.
above kitchen
platform above
and along the
work top and
around and
below kitchen
sink excluding
areas where built
in cupboards are
fixed.
(iv) Built in cupboard with Yes Yes Yes Yes with 2 drawers Yes with 2 drawers
open shelves below
cooking platform shutters
of pre-laminated particle
board 18mm thick below
window sill level of
cooking platform along
one wall
(v) Cooking platform standing Yes Yes Yes Yes Yes
2(i) Wardrobes (One in each One in each (One in (One in each Bed Room) One in each Bed
Built in cupboard with Bed Room ) Bed Room, each Bed upto ceiling height Room upto
R.C.C./pre-laminated 7’- 00" height 7’-00" Room) ceiling height
particle board/Kota stone height 7’-00"
shelves and shutter upto height
ceiling height

(ii) Magic eye in front door One One One One One
(iii) Window sill lining 18mm Kota Stone Kota Stone Kota Kota Stone Marble
thick projected with Kota Stone
stone/marble
(iv) Curtain rods with brackets All rooms All rooms All rooms Drapery rods Drapery rods
(v) Set of Pegs In bath and In bath and In bath, In bath, bed and In bath, bed and
bed rooms bed rooms bed and wardrobes wardrobes
wardrobes
PLINTH AREA RATES 13

SCALES OF SANITARY FITTINGS FOR GENERAL POOL RESIDENTIAL


QUARTERS
Item Item Type I Type II Type III Type IV Type V/VI
No.
1. Indian W.C. Pan One WC Pan One Same as One same as One same as One + One for
with dual flushing Orissa pattern Type I Type I Type I servant quarter
cistern with low level
PVC Flushing
Cistern
2. European type W.C. - - - One with low level One (syphonic
with low level dual PVC flushing type )with
dual flushing cistern cistern matching low
level cistern
2(a) Water Jet with low - - - One One
level European W.C.
3. Wash basin with one One One One Two CP Brass mixer Three CP Brass
pillar tap each type for hot and cold mixer type for hot
water with single and cold water
lever with single lever
4. Tap (kitchen bath & 4 PTMT 4 PTMT 4 C.P. brass 5 C.P. brass 12 (1 PTMT + 11
W.C.) C.P. Brass/ CP brass )
PTMT bib cock
5 Shower C.P. Brass / One PTMT One PTMT One PTMT Two C.P.brass Three C.P. brass
PTMT
6. Towel rail C.P. Brass/ One PTMT One PTMT One PTMT Two C.P. brass Two C.P. brass
PTMT
7. Mirror / Bevelled edge One One One Two Three
/ P.V.C. frame with
PTMT glass shelf
8. Soap rack (Nitch in One One One Two Three
W.C./ Bath)
9. Liquid soap container - - - Two Three
10. Storage tank 500 ltr. 500 ltr. 500 ltr. 750 litre 1000 litre + 500
litre for servant
quarters
11. Nitch with Kota stone One One One Two 3 + 1 for servant
sill in bath room quarter
12. Plumbing for water Yes Yes Yes Yes Yes
purifier and Geyser

Note : Waste coupling in wash basins and grating over the floor trap shall be only of PTMT.
14 PLINTH AREA RATES

SPECIFICATIONS FOR ELECTRICAL INSTALLATION IN RESIDENTIAL QUARTERS


Item No. Description Type I Type II Type III Type IV Type V Type VI Servant
(excluding (excluding Qtrs &
servant servant Garage
quarter & quarter &
Garage) garage )
1. Power Points (15 2 3 4 5 6 7 1
amperes, 6 pins
2. MCB connected 1 1 1 2 4 5 -
socket outlet for A.C.
unit /Geyser complete
with wiring
3. Ceiling Fans 2 3 4 5 6 7 1
4. Exhaust Fans 1 1 2 2 3 3 -
5. Call bells 1 1 1 1 2 3 -
6. Light/Fans/Call bell/5A 17 20 23 27 38 44 5
Plug Points
7. F.I. Fittings excluding 2 3 4 5 7 8 1
Tube and Starter
Type of Wiring Recessed Conduit wiring Concealed
Concealed conduit conduit
wiring wiring
8. EDB MCB Type
A. Single Phase 1 1 1 - - - 1
B. 3 Phase - 1 1 1 -
9. Cable TV Point 1 1 1 1 2 2 -
10. Telephone Point - 1 2 2 -
PLINTH AREA RATES 15

SPECIFICATION FOR NON - RESIDENTIAL BUILDING


ITEM DESCRIPTION SPECIFICATION
NO.
1.0 FOUNDATION As per structural design based on soil investigation.
2.0 SUPER STRUCTURE
2.1 Structure R.C.C. framed construction with filler walls with fly ash bricks /brick work or
load bearing construction in fly ash brick/brick/ stone masonry with intermediate
columns as per design.
2.2 Internal partitions.
2.2.1 Light weight auto claved aerated concrete blocks.
2.2.2 Gypsum Blocks.
2.2.3 Non asbestos double skin cement boards.
2.2.4 Fly ash bricks.
3.0 DOORS & WINDOWS
3.1 Frames:
3.1.1 Door frames of 2nd class Indian teakwood or equivalent in officer’s room.
3.1.2 Anodized / Powder coated/ Polyester powder coated Aluminium windows/doors.
3.1.3 Glazing with reflective glass or double glass using float glass.
3.2 Door Shutters:
3.2.1 Panelled type in 2nd class teak wood or flush door with teak veneered ply/
commercial ply as per CPWD Specifications/as per design.
3.2.2 Anodized/powder coated/ Polyester powder coated Aluminium shutters with
float glass panelling where required.
3.2.3 PVC/FRP door frames & shutters in wet areas.
3.3 Window shutters Factory made Anodised/ powder coated/ Polyester powder coated ‘Z’ section
aluminium frames & shutters for windows.
3.4 Fittings Anodized aluminium /stainless steel or equivalent.
3.5 Fire check door As per fire safety specifications
4.0 FLOORING
4.1 Main entrance hall Pre polished granite flooring.
4.2 Corridors Matt finished vitrified tiles/Granite flooring.
4.3 Rooms Granite tiles/Vitrified tiles/Ceramic tile flooring.
4.4 Lavatory Blocks Granite flooring.
4.5 Flooring in basement Vacuum dewatered concrete.
4.6 Rest of the area Kota Stone flooring.
5.0 STAIRCASE
5.1 Internal staircases Single piece Granite or marble flooring in treads & risers with dado of matching
permanent finish specifications.
5.2 Fire escape staircase Single piece Kota stone flooring in treads & risers with dado of matching
permanent finish specifications.
6.0 RAILING Stainless steel railings.
7.0 TOILETS Granite flooring. Glazed tiles of size not less than 300 x 450 mm in dado.
Granite counters. Stainless steel sinks. Mirrors with moulded PVC frame. FRP/
PVC doors with frames.
16 PLINTH AREA RATES

8.0 ROOFING
8.1 Roof treatment Coba treatment/over deck insulation with Puf slab.
8.2 False ceiling False ceiling in office area & toilets to cover the services as per design requirement.
9. FINISHING
9.1 External Dry stone cladding, washed grit plaster, water proof weather coat paints, structural
glazing, ACP cladding conforming to Energy Conservation Building Code.
9.2 Internal
9.2.1 Gypsum plaster in dry areas.
9.2.2 Cement plaster in wet areas
9.2.3 Dry distemper in service area & basement.
9.2.4 Oil bound distemper/Acrylic emulsion paint/ Textured paint (low V.O.C)
9.3 Painting Doors & windows – Painting/polishing on wood work as per design requirement.
10.0 PROVISION FOR BARRIER
FREE BUILDING Ramps, toilets for physically challenged, chequered tiles use of Braille signages
& lifts etc.GRC (Glass reinforced concrete) tiles in Ramp area.
11.0 LANDSCAPING 10% of the building cost will be kept in Preliminary Estimate for murals and/
Landscape related construction i/c pavement/ paving.
PLINTH AREA RATES 17
ANNEXURE –III

Central Public Works Department



Copy of the Memo no. 29/21/58/WI Dated: New Delhi, Oct. 1983
Subject: Rules for working out plinth area from plans

In order to ensure the adoption of a uniform method of working out plinth areas from plans, the following rules
are laid down. These rules are general in nature and should be taken as a guide. They are based on the fundamental
principle that the plinth area of a building should present a true picture of the covered floor area provided in the
plan.
1. GENERAL
(a) The total plinth area of a building shall be the sum total of the plinth area at every floor including the
basement, if any.
(b) Internal sanitary shafts shall not be included in the plinth area in the case of a residential building at
any floor level.
(c) In case of non-residential building internal shafts for sanitary installations, air-conditioning ducts,
lifts etc. shall be included in the plinth area at all floor levels.
(d) The area of the mumty at terrace level shall not be included in the plinth area. If a Barsati is
provided jointly with mumty then the area of the Barsati excluding mumty at the terrace level shall
be included in the plinth area as shown below in the hatched area.

(e) Towers, turrets domes projecting above the terrace shall not be included in the plinth area at terrace
level, but shall be allowed for separately for costing purposes.

PLINTH AREA OF GROUND FLOOR


The plinth area of the ground floor shall be calculated at the plinth level excluding the plinth off-sets
provided such plinth off-sets are not more than 2 ¼” . In cases where the building consists of – columns
projecting beyond cladding, the plinth area shall be taken up to the external face of the cladding and shall
not be included the projections of the columns.
18 PLINTH AREA RATES

In case open verandah with parapets are protected at the ground floor projecting out of the building, the
full area shall be taken up to the outer line of the external verandah lintel and only 50% of area shall be
taken for the unprotected verandah. Open platform without parapets and terraces at ground floor and
porches, shall not be included in the plinth area but shall be allowed for separately for costing purposes.

PLINTH AREA AT FIRST AND HIGHER FLOORS


The plinth area of first and higher floors shall be calculated at the relevant floor levels. Architectural
bonds, cornice etc. shall not be included in the plinth area even though they may occur at the floor level,
vertical sun breakers or box louvers projecting out also shall not be include in plinth area. See illustrative
sketch below :
PLINTH AREA RATES 19
In the case of projecting balconies protected to their full width by the shades full width roof projections
or by upper in the case of unprotected balconies equivalent area to the extent of 50% of the area of the
balconies shall be included in the plinth area. See illustrative sketch given below:

IV) GALLARIES, MEZZANINE FLOORS, LOFTS


(a) Area of galleries i.e. upper floor of seats in an assembly hall, Auditorium, theatres, etc. shall be
fully included in the plinth area.
(b) Area of mezzanine floor i.e. an intermediate floor introduced between two main floors, shall be
included in the plinth area, if no separate provision is made for the same.
(c) The area of a loft i.e. an intermediate slab just beneath the floor of roof without any direct staircase
leading to it and used for storage purpose shall not be included in the plinth area.

Sd/-
Chief Engineer
Central P.W.D.

(Er. RAM DIYA) (Er. K.L.LANGAR) (Er. M.K.KANCHAN)


ASSTT. ENGINEER-III EXECUTIVE ENGINEER SUPTDG.ENGINEER(S&S)
S&S- II, CPWD (S&S) II, CPWD CPWD, NIRMAN BHAWAN
NIRMAN BHAWAN, N.D. NIRMAN BHAWAN, N.D. NEW DELHI
20 PLINTH AREA RATES

ANNEXURE - 4
PROFORMA FOR CALCULATION OF COST INDEX
S.No. Description Unit Rate as on Weightage Rate at Cost
1.10. 2012 the time of Index
in Rs. revision of
cost Index
1. BRICKS 1000 Nos. 3867.00 8.00
2. CEMENT(OPC) QTL. 587.00 14.50
3. STEEL QTL. 4669.00 19.50
a) 8 & 10 MM(TOR STEEL) 50%
b) 12 & 16 MM (TOR STEEL) 50 %
4. AGGREGATE 20 MM SIZE CUM. 1350.00 6.50
5. SAND(COARSE SAND) CUM. 1293.00 3.00
6. FLOORING ITEMS SQM. 467.00 3.00
(a) MOSAIC TILES 40%
(b) CERAMIC TILES 40%
(c) KOTA STONE 10%
(d) GRANITE STONE 10%
7. PAINTS LITRE 151.00 3.00
(a) SYNTHETIC ENAMEL
PAINT 33.33%
(b) O.B.D. 33.33%
(c) PLASTIC EMULSION 33.33%
PAINT
8. PLY AND COMM. WOOD SQM. 1476.00 5.00
(i) 12 MM THICK PARTICLE
BOARD 33.33%
(ii) STEEL WINDOW
STANDARD Z SECTION 33.33%
(iii) ALUMINIUM WINDOW 33.33%
9. PIPES MTR. 300.00 2.50
(i) 15 MM G.I. PIPE 33.33%
(ii) 100MM SCI PIPES 33.33%
(iii) 20 MM Black Conduit 33.33%
10. LAMPS & FANS EACH 1024.00 3.50
(i) CEILING FANS 48" 50 %
(ii) 1.20 M FLUORSCENT
TUBE WITH FITTINGS 50 %
11. ELECT MACHINERY FITTING EACH 30380.00 2.50
MOTORS 7.5 HP (PUMP SET)
1500 RPM (KIRLOSKAR)
12. WIRES & CABLES COPPER 100 1790.00 4.00
WIRES` MTR.
(a) 1.5 SQMM 70%
(b) 4.0 SQMM 30%
13. LABOUR EACH 309.38 25.00
(i) SKILLED 50 %
(ii) UNSKILLED 50 %
PLINTH AREA RATES 21
ANNEXURE - V
SPECIFICATIONS FOR BUILDINGS
NON- RESIDENTIAL
S.No. Description Item no. Office Hospitals Schools
1 2 3 4 5 6
1 FOUNDATIONS 1.1 Bearing capacity 10 tonnes/square metre.

1.2 Type – Spread foundations isolated/ combined

1.3 Depth.- Upto 1.2 metres below ground level

2. SUPER 2.1 RCC framed construction with filler walls in brick work or load bearing construction in brick/stone
STRUCTURES masonry with intermediate columns where found necessary.
2.2 Internal partition in brick masonry
2.3 RCC chajjas, fins, jalis etc.
3. DOORS & 3.1 Frames of 2nd class Indian teakwood or equivalent or T-iron frame, pressed steel frame as per
WINDOWS CPWD Specifications
3.2 Door shutters; Panelled type in 2nd class teak wood or flush door with commercial ply as per CPWD
Specifications
3.3 Window shutters 2nd class Indian Window shutters 2nd class Indian teak Window shutters 2nd
teak wood wood. Fly proof shutters for all doors class Indian Teak wood
& windows and iron grills for windows in or Steel windows.
ground floor shall be provided for
which provision for extra rate will be
made or steel windows.
3.4 Fittings Anodized aluminium or equivalent
4. FLOORING 4.1 Main entrance hall terrazzo tiles, Main entrance hall terrazzo tiles, Main entrance hall,
kota stone and the like. Lavatory kota stone & the like. Lavotory blocks staircase, lavatory blocks
blocks and corridors & some corridors and other rooms except in-situ mosaic
officers room. stores, weather-maker rooms etc.
mosaic flooring with dado upto 7’0”
height.
Mosaic limited upto 25% of total In corridors & upto sill level in other
area. rooms, the flooring & dado to be
limited to 50% in ordinary cement
and 50% in white cement.
4.2 Rest of the area ordinary cement Rest of the area ordinary cement Rest of the area
concrete concrete ordinary cement
concrete
5. ROOFING 5.1 Filling for drainage lime concrete Filling for drainage lime concrete Filling of drainage lime
concrete finished with
brick tiles
5.2 Water-proofing treatment 4 Water-proofing treatment 4 course Water-proofing
course treatment finished with treatment finished with brick tiles. treatment 4 course
brick tiles treatment finished with
brick tiles.
6. FINISHING 6.1 External water proofing cement External water proofing cement paint External water proofing
paint cement paint
6.2 Internal Officers rooms & important Internal dry distemper in doctors room, Internal – entrance hall,
rooms such as Committee Rooms operation theatre other important principals room,
dry distemper to be limited upto rooms, such as committee room, Committee room etc.
25% of the total area. Rest either X-ray room etc. Limited upto 25% of dry distemper. Rest of
colour or white wash. Main entrance total area. Rest either colour or white the area white or
hall plastic emulsion paint or the like. wash. Main entrance hall, OPD Plastic colour wash. (Low V.O.C)
(Low V.O.C) emulsion paint or the like. (Low V.O.C)
6.3 Door & windows- painting Doors & windows painting Doors & windows
painting
22 PLINTH AREA RATES

SPECIFICATIONS FOR RESIDENTIAL BUILDINGS


Item no. Item Type I, II, III & Servant Qtrs. Type –IV Type –V/VI Hostel
1.1 Foundation Bearing capacity 10 tonnes per sq. metre.
Applicable to all
1.2 Type –spread foundation in RCC isolated
/combined, continuous wall footing with
lean concrete.
1.3 Depth upto 1.2 metres below ground level
2.1 Super structure RCC framed construction with filler walls
in brick work or load bearing construction
in brick/stone masonry with intermediate
columns where found necessary.
2.2 Internal partition- half brick masonry in
cement mortar 1:4

S No. Item Type I, II, III & Servant Qrs. Type IV Type V and VI
3.1 Frames
3.1.1 Window Pressed steel frames made out of Pressed steel frames made Same as Type IV
corrosion resistant coated sheet out of corrosion resistant
of 1.6 mm thick with double rebate coated sheet of 1.6 mm thick
with double rebate/scratch
proof aluminium sheets/poly-
propylene windows
3.1.2 Door T-Iron /Pressed steel/Pre-cast R.C.C. Pressed steel frames made Same as Type IV
frames. out of corrosion resistant
coated sheet of 1.6 mm thick
with single rebate/factory
manufactured precast RCC
frames.
3.2 Shutters
3.2.1 Window M.S. tubular box section corrosion M.S. tubular box section Same as Type IV
resistant coated shutters. Wire mesh corrosion resistant coated
shutters may also be provided at the shutters. Wire mesh shutters
discretion of Zonal Chief Engineer. may also be provided at the
discretion of Zonal Chief
Engineer /Scratch proof
aluminium window. Shutters
to match with frame.
3.2.2 Main Door Double door, one with iron grill with Same as Type I to III. Same as Type I to III
wire mesh mosquito proof and other except that panelling
35 mm thick panelled shutter with will be of both side
hard wood style and rail with decorative,
panelling of pre-laminated particle pre-laminated particle
board, one side decorative other side board.
balancing.
3.2.3 W.C / Bath Solid PVC shutters 28 mm thick Same as Type I to III Same as Type I to III
room
3.2.4 Kitchen Partly panelled and partly wire mesh Same as Type I to III Partly panelled and
door with stainless steel wire mesh. The partly wire mesh with
panelling with pre-laminated particle stainless steel wire mesh.
board, one side decorative-35 mm The panelling with pre-
thick panelled shutter with hard wood laminated particle board,
style and rails. both sides decorative-
35 mm thick panelled
shutter with hard wood
styleand rails.
PLINTH AREA RATES 23
S No. Item Type I, II, III & Servant Qrs. Type IV Type V and VI
3.2.5 Other doors 35 mm thick panelled shutters Same as Type I to III 35 mm thick panelled
with hard wood style and rail shutters with hard wood
with panelling of prelaminated style and rail with
board, one side decorative. panelling of pre
laminated board, both
sides decorative.
3.3 Fittings Powder coated M.S. fittings/ Power coated aluminium/ Same as type IV
stainless steel fittings stainless steel fittings
3.4 Peep hole and
security chain
for external
door only. Yes Yes Yes

Note : 1. In item no. 3 of Wood work, if any other option of local material is available, the same can also be used by the
respective Chief Engineers.
2. External sliding door bolt and handles will be in powder coated M.S. or stainless steel.
3. Over deck insulation with PUF Slab/Koba treatment on roofing in all type of quarters.
S No. Item Type I, II, III & Servant Qrs. Type IV Type V and VI
4 Flooring
4.1 In rooms, Mosaic flooring and skirting with Same as Type 1 to III Mosaic/ Terrazzo tile flooring
kitchen, internal ordinary cement except in common with white cement. In
circulation area circulation area and staircase kitchen, ceramic tiles/marbles
flooring
4.2 Common Kota stone flooring and matching Same as Type I to III Same as Type IV
circulation skirting. In staircase, single piece
area, staircase Kota stone shall be used
4.3 Kitchen work Kota stone Udaipur green marble/Granite Granite stone
top stone
4.4 Toilets Mosaic Ceramic Tiles Ceramic Tiles
4.5 Skirting/Dado Ceramic glazed tiles in Indian Type Same as Type I to III Ceramic glazed tiles upto
WC upto 90 cm. height and bath ceiling height with a
room upto door jamb height. decorative band of tiles.
5.0 Finishing
5.1 External Acrylic smooth exterior finish or Premium Acrylic smooth Premium Acrylic smooth
washed stone grit plaster or exposed exterior finish with additive exterior finish with additives
brick work of silicone or washed mosaic of silicone or washed mosaic
plaster in ordinary cement plaster in ordinary cement
or exposed brick work or exposed brick work.
5.2 Internal All walls and ceilings to be treated All walls & ceiling to be treated All walls & ceiling to be
with the 2 mm thick POP followed with 2 mm thick POP followed treated with 2mm thick POP
with a coat of acrylic/ oil bound with a coat of acrylic / oil bound plaster and cornices followed
distemper except kitchen, bath & WC distemper except kitchen, bath with a coat of plastic
and all ceiling, which will be done with & WC and all ceilings, which will emulsion paint except kitchen,
white wash. Synthetic enamel paint be done with white wash. bath and WC and all ceilings,
on all wood work and steel work. Synthetic enamel paint on all which will be done with white
wood work and steel work. wash. Synthetic enamel paint
on all wood work and steel
work.
24 PLINTH AREA RATES

SCALE OF AMENITIES FOR GENERAL POOL ACCOMMODATION


Item Item Type I Type II Type III Type IV Type V/VI
No.
1 Kitchen
(i) Shelves in tiers not more Yes Yes Yes Covered cup boards Same as Type IV
than 400mm wide along above sill level with pre-
one wall laminated decoarative
1 " thick board.
(ii) Kitchen sink Stainless Same as Same as Stainless steel sink with Stainless steel
steel sink Type -I Type - I drain board size 510 X sink of size 510
without drain 1040 mm with bowl depth x 1040 mm with
board size 200 mm bowl depth of
610 X 510 mm 250 mm with
with bowl draining board/
depth 200 mm. vitreous china
sink with
draining board of
size 600 x 450 x
250 mm
(iii) Dado Yes Yes Yes Yes Ceramic glazed
Ceramic glazed tiles for tiles upto 60 cm
60cm. above work top and above cooking
around sunken floor platform all
around
(iv) Built in cupboard with Yes Yes Yes Yes with 2 drawers Yes with 2 drawers
open shelves below
cooking platform shutters
of pre-laminated particle
board 18mm thick below
window sill level of
cooking platform along
one wall
(v) Cooking platform standing Yes Yes Yes Yes Yes
2(i) Wardrobes One in each One in each One in One in each Bed Room One in each Bed
Built in cupboard with Bed Room Bed Room, each Bed upto ceiling height Room upto
R.C.C./pre-laminated 7’- 00" height 7’-00" Room ceiling height
particle board/Kota stone height 7’-00"
shelves and shutter upto height
ceiling height

(ii) Magic eye in front door One One One One One
(iii) Window sill lining 18mm Kota Stone Kota Stone Kota Kota Stone Marble
thick projected with Kota Stone
stone/marble
(iv) Curtain rods with brackets All rooms All rooms All rooms Drapery rods Drapery rods
(v) Set of Pegs In bath and In bath and In bath, In bath, bed rooms and In bath, bed
bed rooms bed rooms bed rooms wardrobes rooms and
and wardrobes
wardrobes
PLINTH AREA RATES 25

SCALES OF SANITARY FITTINGS FOR GENERAL POOL RESIDENTIAL QUARTERS


Item Item Type I Type II Type III Type IV Type V/VI
No.
1. Indian W.C. Pan One WC Pan One Same as One same as One same as One + One for
with flushing cistern Orissa pattern Type I Type I Type I servant quarter
with low level
PVC Flushing
Cistern
2. European type W.C. - - - One with low level One (syphonic
with low level PVC flushing cistern type )with
flushing cistern matching low
level cistern
2(a) Water Jet with low - - - One One
level European W.C.
3. Wash basin with one One One One Two mixer type for Three mixer
tap each hot & cold water type for hot
& cold water
4. Tap (kitchen bath & 4 PTMT 4 PTMT 4 C.P. brass 5 C.P. brass 12 (1 PTMT + 11
W.C.) C.P. Brass/ CP brass )
PTMT bib cock
5 Shower C.P. Brass / One PTMT One PTMT One PTMT Two C.P.brass Three C.P. brass
PTMT
6. Towel rail C.P. Brass/ One PTMT One PTMT One PTMT Two C.P. brass Two C.P. brass
PTMT
7. Mirror / Bevelled edge/ One One One Two Three
P.V.C. frame with
PTMT glass shelf
8. Soap rack (Nitch in One One One Two Three
W.C./ Bath)
9. Liquid soap container - - - Two Three
10. Storage tank 500 ltr. 500 ltr. 500 ltr. 750 litre 1000 litre + 500
litre for servant
quarter
11. Nitch with Kota stone One One One Two 3 + 1 for servant
sill in bath room quarter

Note : Waste coupling in wash basins and grating over the floor trap shall be only of PTMT.
26 PLINTH AREA RATES

SPECIFICATIONS FOR ELECTRICAL INSTALLATION IN RESIDENTIAL QUARTERS


Item No. Description Type I Type II Type III Type IV Type V Type VI Servant
(excluding (excluding Qtrs &
servant servant Garage
quarter & quarter &
Garage) garage )
1. Power Points (15 2 3 4 5 6 7 1
amperes, 6 pins
2. MCB connected 1 1 1 2 4 5 -
socket outlet for A.C.
unit /Geyser complete
with wiring
3. Ceiling Fans 2 3 4 5 6 7 1
4. Exhaust Fans 1 1 1 1 1 1 -
5. Call bells 1 1 1 1 2 3 -
6. Light/Fans/Call bell/5A 17 20 23 27 38 44 5
Plug Points
7. F.I. Fittings excluding 2 3 4 5 7 8 1
Tube and Starter
Type of Wiring Recessed Conduit wiring Concealed conduit wiring
8. EDB MCB Type
A. Single Phase 1 1 1 - - - 1
B. 3 Phase - - - 1 1 1 -
9. Cable TV Point 1 1 1 1 2 2 -
10. Telephone Point - - - 1 2 2 -