Room Air Conditioner


SVC MANUAL(Exploded View)
MODEL : TS-C1825DA1

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
Product Model TS-C1825DA1
Sales Model SJ182CD
Capacity
Cooling Capacity Btu/h 18000
Heating Capacity Btu/h -
Electrical Parts
Voltage. Frequency/Phase Φ / V / Hz 1,220V,60Hz
Power Input Cooling W 1800
Heating W -
Running Current Cooling A 8.4
Heating A -
Performance
EER Cooling Btu/h 10.0
COP Heating W/W -
Air Circulation Indoor,Max ㎥/min(cfm) 13.0
Outdoor,Max ㎥/min(cfm) 28
Moisture Removal l/h 2.5
Sound Level Indoor,H/M/L dB(A)+3 42
Outdoor,Max dB(A)+3 56
Feature
Neo Plasma Air Purifying System N
Anti Corrasion N
Temperature Control Y
CHAOS Wind(Auto Wind) N
Airflow Direction Control(up&down) Auto
Airflow Direction Control(left&right) Manual
Remocon Type Wireless Simple
Setting Temperature Range Cooling 18-30
Heating -
Auto Chage Over N
Auto Clean N
Seps,Fan/Cool 3/4
o
Temperature Increment 1 C
Timer 7Hr,Off
Sleep Operation Y
Restart Delay(Minute) 3
Hot start -
Jet Cool Y
Compressor Type Rotary,PH250(Toshiba)
Installation & Stuffing
Net Dimensions WxHxD mm 1090*314*190/770*540*245
Net Weight Indoor/Outdoor kg 14/41
Q'ty With S/parts 20/40FT
Without S/parts 20/40FT

Note: Some of functions are slightly different depending upon models.


O : Applied, - : No relation The specification may be subject to change without prior notice for purpose of
* For circuit breaker rating, please conform to local standards wherever necessary. improvement.

2 Room Air Conditioner


2. Piping Diagrams
Indoor Unit Outdoor Unit

Liquid Side Capillary Tube

2-Way Valve
Th2

Th1

Heat Heat
Exchanger Exchanger
(Evaporator) (Condenser)

Compressor
Gas Side

Accumulator
3-Way Valve
High Pressure S/W

Cooling

LOC. Description PCB Connector


Th1 Thermistor for indoor air temperature
CN-TH1
Th2 Thermistor for evaporating temperature

Service Manual 3
3. Wiring Diagrams
Indoor Unit

GN/YL
BR
BL

1(L)2(N) 3
GN/YL
BR
BL

3854A23009

CN-U/D
RY-COMP CN-HVB
RY-COMP4 CN-DISP2

FUSE
CN-N2

CN-N1

CN-MOTOR

4 Room Air Conditioner


Outdoor Unit

BLUE

CAPACITOR
RED H C F RED

R S BLUE BLUE

OVERLOAD
PROTECT
C

FAN

YELLOW
BROWN

BLUE

YELLOW/GREEN

TERMINAL BLOCK 1(L) 2(N)


BLUE
BROWN

THE UNIT INDOOR

OUTDOOR DIAGRAM WIRING


EBY36312302

Capacitor
Terminal Block

Service Manual 5
Exploded View

Exploded View
1. Indoor Unit
135316

152302
135313

131410 733010

342800

359011
135311
354210

147581

352115
35211B 346810

268711A 352116 135516

268711D
352150

W0CZZ

146811

267110 249951

6 Room Air Conditioner


Exploded View

Exploded View
Outdoor Unit 554031
437212

552112
435512

552111
649950

549610
435511
559010

546810

435301 447910

554160
552203-1
550140

430410

437210 552203-2

Service Manual 7
P/NO : MFL37322726 JANUARY, 2008

You might also like