6 4
6 4
6 4
Cause Remedy
YES
Defective
YES Check pressure hydraulic system
at EPPR valve
NO Check electric Defective Replace
current at EPPR SPEC : 5~20 kgf/cm2
NO
EPPR valve
valve See TEST 3
SPEC : 100~700 mA
See TEST 2
Defective MCU Replace
Check if HCESPN NO
140 active fault
display on the LCD YES
Short circuit or Check & repair
poor connection wire harness or
between CN-53 between CN-53
Check resistance
YES at EPPR valve -CN-75 -CN-75
Wiring diagram
MCU
FUSE
4
NO.10
8
7 1
18 8 2
21096MS01
6-40
2) TEST PROCEDURE SPEC : 15~25̫(20˚C)
(1) Test 1 : Check resistance at connector
CN-75. CN-75
Η Starting key OFF.
Θ Disconnect connector CN-75 from EPPR Multimeter
valve at main hydraulic pump.
Ι Check resistance between 2 lines as
figure.
EPPR valve
Main pump
2107A5MS15
(3) Test 3 : Check pressure at EPPR valve. Spec : 2~25 kgf/cm2 (30~350 psi)
Η Remove plug and connect pressure
gauge as figure.
Pressure adjusting
ÂGauge capacity : 0 to 50 kgf/cm2 screw locknut
Pilot pressure
(0 to 710 psi) CN-75
supply line
Θ Start engine.
Ι Set S-mode and cancel auto decel
mode.
Κ Position the accel dial at 10.
EPPR valve
Λ If tachometer show approx 1750Ü50 rpm
check pressure at relief position of bucket
circuit by operating bucket control lever. Main pump
Μ If pressure is not correct, adjust it.
Ν After adjust, test the machine. 2107A5MS13
6-41
2. ENGINE STALL
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Not enough Check engine
engine power fault
YES Check pressure Contact cummins
at EPPR valve
SPEC : 15~25̫(20˚C)
See TEST 1
NO
Defective EPPR Replace
valve
Wiring diagram
MCU
FUSE
4
NO.10
8
7 1
18 8 2
21096MS01
6-42
2) TEST PROCEDURE SPEC : 100~700 mA
(1) Test 4 : Check electric current at EPPR Adapter(P/no.:21Q6-50410)
Main pump
21095MS21
(2) Test 5 : Check pressure at EPPR valve at SPEC : 2~25 kgf/cm2 (30~350 psi)
S-mode Pressure adjusting
Η Connect pressure gauge at EPPR valve. Pilot pressure
screw locknut
CN-75
supply line
Θ Start engine.
Ι Set the accel dial at "10" (max)
Κ Set S-mode with 1750Ü50 rpm.
Λ Operate bucket lever completely push or
pull. EPPR valve
Μ Hold arm lever at the end of stroke.
ΝCheck pressure at relief position.
Main pump
2107A5MS13
6-43
3. MALFUNCTION OF CLUSTER OR MODE SELECTION SYSTEM
· Fault code : HCESPN 840, FMI 2
※ Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
No power supply to Check fuse No.3
See if all lamps the MCU
YES off in the MCU
case YES
Y R G MCU failure Replace
Y R G
See if HCESPN
840 active fault NO
display on the LCD
NO Y R G
ⓐ
NO
OK
Check connection Cluster failure Replace
between CN-51
ⓐ (33) - CN-56(4) or
CN-51(23) -
CN-56(8) No connection Check and repair
NO
KEY OFF
Wiring diagram
CLUSTER MCU
BATT. 24V
SIG_3
GND
TX 4 1 33
IG 24V 8 2 23
SIG_2
CN-56 CN-5 2
CAMERA SIG
RX CN-51
FUSE
NO.3
21096MS03
6-44
4. MALFUNCTION OF ACCEL DIAL
· Fault code : HCESPN 714, FMI 3 or 4
※ Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
YES
Open circuit or Replace or repair
poor connection
YES Check voltage between CN-16
between CN-16
(2) -CN-52 (21)
(2)-GND
Check voltage
between YES Check voltage Spec : actuator operating
NO
Open circuit or Replace or repair
CN-52(21)-GND between 1~5V poor connection
CN-7(15)-GND between CN-7
Spec : actuator operating (15) -CN-16 (2)
1~5V Spec : actuator operating
1~5V YES
See TEST 6 Check resistance Defective accel Replace
between dial
NO CN-142(B)- CN-52
Check voltage CN-7(15) Open circuit or Replace or repair
NO
between Spec : 0Ω poor connection
NO between CN-142 21
CN142(A)-(C)
(B) -CN-7 (15)
Spec : 5V
YES
Open circuit or Replace or repair
poor connection MCU
between CN-142
(A) -CN-7 (14) or ACCEL DIAL
Check voltage CN-142 (C )- + A 14 3 6
between CN-7 (16) B
NO CN-7(14)-(16) S 15 2 7
YES
- C 16 1
Open circuit or Replace or repair
Spec : 5V poor connection CN-142
between CN-7 CN-7 CN-16 CN-51
Check voltage (14) -CN-16 (3) or
NO
between CN-16 CN-7 (16 )-
(1)-(3) CN-16 (1)
Spec : 5V
Open circuit or Replace or repair
NO poor connection
between CN-16
(3) -CN-51 (6) or
CN-16 (1 )-
CN-51 (7)
21096MS04
6-45
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 6 : Check voltage at CN-52(21) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper.
MCU
Θ Insert prepared pin to rear side of PIN
connectors : One pin to (21) of CN-52. CN-51 CN-52 CN-53
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS04A
6-46
5. AUTO DECEL SYSTEM DOES NOT WORK
· Fault code : HCESPN 105, FMI 0~4 (work pressure sensor)
HCESPN 108, FMI 0~4 (travel oil pressure sensor)
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
YES
Defective travel Replace
Check voltage
NO pressure switch
between CD-6(A)
and (C)
Short circuit or poor Replace or repair
NO
Check voltage SPEC : connection
between CN-52 Key ON : 24±2V between CN-51(4)-
(26)-GND and CD-6(A) and / or
CN-52(35)-GND CN-51(5)-CD-6(C)
(fault code 108
SPEC :
Actuator operating : 1~5V
displayed)
See TEST 7, 8 YES
Defective work Replace
Check voltage
pressure sensor
between CD-7(A)
NO and (C)
Short circuit or poor Replace or repair
NO
SPEC : connection
Key ON : 24±2V between CN-51(4)-
CD-7(A) and / or
CN-51(5)-CD-7(C)
(fault code 105
displayed)
Wiring diagram
CN-51
CD-6
4 A SUPPLY
B SIG
5 C RETURN
TRAVEL PRESSURE SENSOR
MCU
26 CD-7
A SUPPLY
35 B SIG
C RETURN
CN-52 WORK PRESSURE SENSOR
21096MS05
6-47
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 7 : Check voltage at CN-52(26) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
MCU
copper.
PIN
Θ Insert prepared pin to rear side of CN-51 CN-52 CN-53
Multimeter
10 9 8 7 6 5 4 3 2 1
CN-52
20 11 Female
30 21
35
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS05A
6-48
6. MALFUNCTION OF PUMP 1 PRESSURE SENSOR
· Fault code : HCESPN 120, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
YES
Short circuit or Replace or repair
poor connection
YES Check voltage between CN-52-
between
CN-1(3)-GND (29)-CN-1(3)
Check voltage SPEC : Detective P1 Replace or repair
between CN-52 Actuator operating: 1~5V NO
Check voltage pressure sensor
(29) - GND YES between Short circuit or Replace or repair
SPEC : CD-42(A)-(C) poor connection
Actuator operating: 1~5V between CN-1(3)-
See TEST 9 SPEC :
Key ON : 24±2V CD-42(B)
Wiring diagram
CN-51
CD-42
4 2 A SUPPLY
3 B SIG
5 4 C RETURN
PUMP 1 PRESSURE SENSOR
CN-1
MCU
29
CN-52
21096MS06
6-49
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 9 : Check voltage at CN-52(29) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (29) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
29
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS06A
6-50
7. MALFUNCTION OF PUMP 2 PRESSURE SENSOR
· Fault code : HCESPN 121, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
YES
Short circuit or Replace or repair
poor connection
YES Check voltage between CN-52-
between
CN-1(1)-GND (38)-CN-1(1)
Check voltage SPEC : Detective P2 Replace or repair
between CN-52 Actuator operating: 1~5V NO
Check voltage pressure sensor
(38) - GND YES between Short circuit or Replace or repair
SPEC : CD-43(A)-(C) poor connection
Actuator operating: 1~5V between CN-1(1)-
See TEST 10 SPEC :
Key ON : 24±2V CD-43(B)
Wiring diagram
CN-51
CD-43
4 2 A SUPPLY
1 B SIG
5 4 C RETURN
PUMP 2 PRESSURE SENSOR
CN-1
MCU
38
CN-52
21096MS07
6-51
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 10 : Check voltage at CN-52(38) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (38) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
30 21
38
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS07A
6-52
8. MALFUNCTION OF PUMP 3 PRESSURE SENSOR
· Fault code : HCESPN 125, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
YES
Short circuit or Replace or repair
poor connection
YES Check voltage between CN-52-
between
CN-1(5)-GND (36)-CN-1(5)
Check voltage SPEC : Detective P3 Replace or repair
between CN-52 Actuator operating: 1~5V NO
Check voltage pressure sensor
(36) - GND YES between Short circuit or Replace or repair
SPEC : CD-44(A)-(C) poor connection
Actuator operating: 1~5V between CN-1(5)-
See TEST 11 SPEC :
Key ON : 24±2V CD-44(B)
Wiring diagram
CN-51
CD-44
4 2 A SUPPLY
5 B SIG
5 4 C RETURN
PUMP 3 PRESSURE SENSOR
CN-1
MCU
36
CN-52
21096MS08
6-53
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 11 : Check voltage at CN-52(36) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (36) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
30 21
36
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS08A
6-54
9. MALFUNCTION OF NEGATIVE 1 PRESSURE SENSOR
· Fault code : HCESPN 123, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
Wiring diagram
CN-51
CD-70
4 A SUPPLY
B SIG
5 C RETURN
NEGATIVE 1 PRESSURE SENSOR
MCU
37
CN-52
21096MS09
6-55
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 12 : Check voltage at CN-52(37) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (37) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
30 21
37
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS09A
6-56
10. MALFUNCTION OF NEGATIVE 2 PRESSURE SENSOR
· Fault code : HCESPN 124, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
Wiring diagram
CN-51
CD-71
4 A SUPPLY
B SIG
5 C RETURN
NEGATIVE 2 PRESSURE SENSOR
MCU
27
CN-52
21096MS10
6-57
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 13 : Check voltage at CN-52(27) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (27) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 27 11
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS10A
6-58
11. MALFUNCTION OF SWING PRESSURE SENSOR
· Fault code : HCESPN 135, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
Wiring diagram
CN-51
CD-24
4 A SUPPLY
B SIG
5 C RETURN
SWING PRESSURE SENSOR
MCU
24
CN-52
21096MS11
6-59
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 14 : Check voltage at CN-52(24) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (24) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
24
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS11A
6-60
12. MALFUNCTION OF ARM IN/OUT & BUCKET IN PRESSURE SENSOR
· Fault code : HCESPN 133, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
Wiring diagram
CN-51
CD-35
4 A SUPPLY
B SIG
5 C RETURN
ARM IN/OUT & BUCKET IN
PRESSURE SENSOR
MCU
25
CN-52
21096MS12
6-61
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 15 : Check voltage at CN-52(25) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (25) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
25
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS12A
6-62
13. MALFUNCTION OF BOOM UP PRESSURE SENSOR
· Fault code : HCESPN 127, FMI 0~4
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
Wiring diagram
CN-51
CD-32
4 A SUPPLY
B SIG
5 C RETURN
BOOM UP PRESSURE SENSOR
MCU
23
CN-52
21096MS13
6-63
2) TEST PROCEDURE SPEC : Actuator operating : 1~5 V
(1) Test 16 : Check voltage at CN-52(23) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (23) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
23
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS13A
6-64
14. MALFUNCTION OF POWER MAX
· Fault code : HCESPN 166, FMI 5 or 6
※ Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Short circuit or poor Repair or replace
connection between
YES Check resistance CN-88(1)-CN-52 (7)
between CN-88
(1)-(2)
Defective power
NO
YES Check resistance SPEC: 15-35Ω max. solenoid valve Repair or replace
between CN-53 See TEST 18 Check hydraulic
(30)-GND
system
Wiring diagram
MCU
CN-88
7 1
2
CN-52
POWER MAX SOLENOID
30 5
FUSE
6
NO.28
CN-53 CN-4
CS-29
1
2
21096MS14
6-65
2) TEST PROCEDURE SPEC : Key ON : 24Ü1V
Key OFF : 0V
(1) Test 17:
17 Check voltage between connector
CN-88(2) - GND.
Η Disconnect connector CN-88 from power
max solenoid valve. Power max switch
Θ Start key ON.
Ι Check voltage as figure.
LH RCV-lever
CN-88
Power max
solenoid valve
2 1
1 2
GROUND
Multimeter
21096MS14A
LH RCV-lever
CN-88
Power max 2 1
solenoid valve
1 2
Multimeter
21096MS14B
6-66
15. MALFUNCTION OF BOOM PRIORITY EPPR VALVE
· Fault code : HCESPN 141, FMI 5 or 6
ö Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Short circuit or poor Repair or replace
connection between
CN-53(19)-CN-133
Check resistance (1) or CN-53(9)-
between CN-133(2)
CN-133(1)-(2)
SPEC : 20~30V
KEY : ON
Defective EPPR Repair or replace
NO
valve
Wiring diagram
MCU
19
CN-133
9 2
BOOM PRIORITY
EPPR VALVE
CN-53
21096MS15
6-67
16. MALFUNCTION OF ARM REGENERATION SOLENOID
· Fault code : HCESPN 170, FMI 5 or 6
※ Before carrying out below procedure, check all the related connectors are properly inserted.
1) INSPECTION PROCEDURE
Cause Remedy
YES
Defective MCU Replace
Wiring diagram
MCU
CN-135
1 1
FUSE
NO.28
CN-52
21096MS16
6-68
2) TEST PROCEDURE SPEC : Key ON : 24±2 V
(1) Test 19 : Check voltage at CN-52(1) and
ground.
Η Prepare 1 piece of thin sharp pin, steel or
copper. MCU
Θ Insert prepared pin to rear side of PIN
CN-51 CN-52 CN-53
connectors : One pin to (1) of CN-52.
Ι Starting key ON.
Κ Check voltage as figure.
CN-52 Female
10 9 8 7 6 5 4 3 2 1
20 11
30 21
40 39 38 37 36 35 34 33 32 31
GROUND
Multimeter
21096MS16A
6-69