Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ca Choke Valve Series: Technical Data Sheet For Maximum Trim Size of 1.18"

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

THE ART OF FLOW CONTROL

When you are serious about your flow control,


LFA Provides genuine solutions.

CA CHOKE VALVE SERIES


TECHNICAL DATA SHEET FOR
MAXIMUM TRIM SIZE OF 1.18”

The ‘CA’ product family of production choke valves utilize a 0.75”


To 1.18” orifice and offer the ability to manually or remotely control
well production flow at the wellhead and or flowline with a more
conventional type choke body. The cage & plug flow trim is pressure
balanced to minimize the stem loads and provide low operating
torques. Standard end connections range in size from 1” to 4”.

DESIGN CAGE & PLUG NEEDLE CAGE & PLUG


TRIM SIZE: 0.75” 1.00” 1.18”
CV: 11.2 27.0 26.5
MAX BEAN SIZE: 48/64” 64/64” 76/64”
END CONNECTION: CUSTOMER SPECIFIED

VALVE MODEL CA
BODY TYPE Right Angle
BODY SIZE Suitable for max. 1.18” orifice
BODY RATING 15,000 psi (max.), Limited by the rating of the body end connection.
INLET CONNECTION See ‘End Connection’ table below
OUTLET CONNECTION See ‘End Connection’ table below
BONNET TYPE Lancaster Proprietary Bonnet
BODY / BONNET MATERIAL See 'Material Options' table below
STEM MATERIAL See ‘Material Options’ table below
SEAL MATERIAL See ‘Material Options’ table below
TRIM STYLE Equal Percentage Cage and Plug or Needle
BALANCED / UNBALANCED Balanced
FLOW CHARACTERISTIC Equal Percentage or Linear
TRIM MATERIAL See ‘Trim Options’ table below
DESIGN CV See the table above
LEAKAGE CLASSIFICATION ANSI/FCI 70-2 Class IV (Standard)
THE ART OF FLOW CONTROL
When you are serious about your flow control, LFA Provides genuine solutions.

API SPEC. 6A MATERIAL CLASS DESIGNATIONS

Temperature Certification Material Class Designations


Class Level AA BB CC DD EE FF HH
TECHNICAL DATA SHEET FOR MAXIMUM TRIM SIZE OF 1.18”

STD/PSL-1 BB BB FF EE EE FF HH
P-U
-20F to 250F PSL-2 EE EE FF EE EE FF HH
CA CHOKE VALVE SERIES

-29C to 82C
PSL-3 EE EE FF EE EE FF HH
STD/PSL-1 EE EE FF EE EE FF HH
L-U
-50F to 250F PSL-2 EE EE FF EE EE FF HH
-46C to 121C
PSL-3 EE EE FF EE EE FF HH

NOTES: other temperature classes are available upon request

BB-GENERAL FF- SOUR HH- SOUR


EE-SOUR SERVICE
SERVICE SERVICE SERVICE
RECOMMENDED General Oil, Sour (H2S) Sour (H2S) High Sour (H2S)
SERVICE Corrosive (CO2) Low Corrosive (CO2) Corrosive (CO2) High Corrosive (CO2)
Clad Low Alloy Steel
Carbon Steel (60K) Carbon Steel (60K) Carbon Steel (60K)
BODY Low Alloy Steel (75K) Low Alloy Steel (75K) Low Alloy Steel (75K)
Corrosion Resistant
Alloy
Carbon Steel (60K) Carbon Steel (60K) Carbon Steel (60K) Clad Low Alloy Steel
BONNET Low Alloy Steel (75K) Low Alloy Steel (75K) Low Alloy Steel (75K) Corrosion Resistant
Stainless Steel (75K) Stainless Steel (75K) Stainless Steel (75K) Alloy
AISI 17-4PH AISI 17-4PH Inconel 625 or Inconel 625 or
STEM Low Alloy Steel Low Alloy Steel Inconel 718 Inconel 718
AISI 17-4PH AISI 17-4PH
PLUG/CAGE
Low Alloy Steel w/ Low Alloy Steel w/ Inconel 718 w/ TCC Inconel 718 w/ TCC
ASSEMBLY TCC TCC

SEALS PTFE/PEEK PTFE/PEEK PTFE/PEEK PTFE/PEEK

NOTE: The materials supplied may change based on the customers NACE service designation (i.e.- “x.xx- NL”)
THE ART OF FLOW CONTROL
When you are serious about your flow control, LFA Provides genuine solutions.

TECHNICAL DATA SHEET FOR MAXIMUM TRIM SIZE OF 1.18”


CA CHOKE VALVE SERIES

C D
Connection Working Dim. A B
Manual Mounting
Size Pressure psig Ref. Outlet Inlet
Operator Flange
1.00” (25.4) Nom. Orifice (Adj.-Pos., 64/64 Linear Needle or 76/64 EP Cage), Max CV = 26.5
2” NPS, RF ANSI 600 LB. 7.62 (194) 7.62 (194)
3” NPS, RF ANSI 600 LB. 8.00 (200) 8.00 (200)
4” NPS, RF ANSI 600 LB. 10.75 (273) 10.75 (273)
2” NPS, RTJ ANSI 900 LB. 8.75 (222) 8.75 (222)
3” NPS, RTJ ANSI 900 LB. 8.75 (222) 8.75 (222)
4” NPS, RTJ ANSI 900 LB. 11.25 (286) 11.25 (286) 20.03 18.50
2” NPS, RTJ ANSI 1500 LB. 8.81 (224) 8.81 (224) (508.76) (469.90)

3” NPS, RTJ ANSI 1500 LB. 9.94 (224) 9.94 (224)


4” NPS, RTJ ANSI 1500 LB. 11.31 (287) 11.31 (287)
2” NPS, RTJ ANSI 2500 LB. 8.75 (222) 8.75 (222)
3” NPS, RTJ ANSI 2500 LB. 9.38 (238) 9.38 (238)
4” NPS, RTJ ANSI 2500 LB. 11.62 (295) 11.62 (295)
THE ART OF FLOW CONTROL
When you are serious about your flow control, LFA Provides genuine solutions.

C D
Connection Working Dim. A B
Manual Mounting
Size Pressure psig Ref. Outlet Inlet
Operator Flange
2-1/16” (52.38) API 5,000 6.89 (175) 7.99 (203)
TECHNICAL DATA SHEET FOR MAXIMUM TRIM SIZE OF 1.18”

2-9/16” (65.09) API 5,000 8.19 (208) 9.33 (237)


3-1/16” (77.79) API 5,000 9.69 (246) 9.57 (243)
CA CHOKE VALVE SERIES

4-1/16” (103.19) API 5,000 10.12 (257) 12.64 (321)


1-13/16” (46.04) API 10,000 7.68 (194) 8.82 (224)
2-1/16” (52.39) API 10,000 7.68 (195) 8.82 (224) 20.03 18.50
2-9/16” (65.09) API 10,000 8.19 (208) 9.33 (237) (508.76) (469.90)

3-1/16” (77.79) API 10,000 7.80 (198) 8.94 (227)


4-1/16” (103.19) API 10,000 9.82 (252) 11.50 (292)
1-13/16” (46.04) API 15,000 8.46 (215) 9.65 (245)
2-1/16” (52.39) API 15,000 8.86 (225) 10.32 (262)
2-9/16” (65.09) API 15,000 10.51 (267) 11.73 (298)
3-1/8” (79.38) API 15,000 10.35 (263) 11.61 (295)

* “C” and “D” shown with 3” x 2” reduced orifice trim


1. Using our 24vDC actuator shown, “E” is 11.97”; Pneumatic & Hydraulic units are also available as well as other
Electric units
2. For sizes or dimensions not shown, for ANSI flanges or hub connections, contact sales or engineering
3. In addition to “C”, provide clearance for bonnet and trim removal as follows (worse case – with trim in fully
closed position): 1.0” (25.4) Nominal, add 7.81” (198.37) for needle trim; add 6.75” (171.45) for cage trim
4. (xxx.xx) dimensions shown in parenthesis are in millimeters (mm)
5. Orifices in X/64ths are openings with the equivalent area of a circle with the diameter of X/64ths of an inch;
64/64ths = 1.00”
6. API 5,000 psig is equal to 34.473 MPa; 10,000 psig = 68.946 MPa; 15,000 psig = 103.420 MPa; 20,000 psig =
137.893 MPa.
7. Dimensions shown above are subject to change without notice. Other dimensions are available, please consult
the Lancaster engineering department.