BA Rainstar E11-E51 Engl
BA Rainstar E11-E51 Engl
BA Rainstar E11-E51 Engl
for
Rainstar
Series E 11 – E 51
The present manual is a very important document that describes how to operate and BAUER
Rainstar E.
This manual describes the system as detailed as possible. If you need still more information, please
contact your dealer or turn directly to BAUER in Voitsberg/Austria.
Please note that the content of this manual neither constitutes part of nor alters in any way any previous
or existing agreement, promise or legal relationship. BAUER’s commitment is based solely on the
respective purchase contract which also contains the complete and only valid warranty agreement. Said
contractual warranty is neither extended nor limited by the content of this manual.
All information contained in the present manual is based on the latest product details available at the
time of printing.
BAUER reserves the right to change without notice without assuming any liability!
BAUER RAINSTAR E is designed for highest performance safety and reliability provided it is operated
in accordance with the present operating instructions.
Therefore you should study this manual thoroughly before starting your BAUER RAINSTAR E !
Strictly observe all instructions pertaining to system handling, operation and service!
On this condition, BAUER RAINSTAR E will operate to your satisfaction for many years!
Non-observance of this manual may cause personal injury or damage the equipment!
This manual is to be considered an integral part of BAUER RAINSTAR E. Suppliers of both new and
used systems are advised to put down in writing that they delivered the manual together with the
system.
Please make this manual available to your staff. State the pump type and serial number of your
BAUER RAINSTAR E in all inquiries, correspondence, warranty problems, or parts orders.
1
Serial number :
Dealer: Name:
Adresse:
ph./fax:
Date of shipment:
Address:
ph. / fax:
Note: Please make a note of the type and serial number of your Rainstar and accessories. Be sure to specify these
details every time you contact your dealer.
1
In all warranty claims and correspondence relating to this machine it is essential to specify the full serial number group including all letters.
This applies to both the machine and the components concerned. We cannot emphasise this point often enough.
Qualified operators are persons who on account of their training, experience and instruction as well as their
knowledge of relevant standards, rules, precautions to be taken for accident prevention, and prevailing
operating conditions, have been authorised by the person in charge of plant safety to perform the respective
tasks required, and in doing so are able to recognise and avoid potential hazards. Among other things,
knowledge of first-aid procedures is also required.
Product liability
As defined by the product liability law every farmer is also an entrepreneur!
According to §9 PHG (Product Liability Law), liability for damage to corporeal things caused by defective
products is expressly excluded. This exclusion of liability also applies to parts not manufactured by BAUER
itself but purchased from external suppliers.
Intended use
• BAUER Rainstar is built exclusively for normal agricultural applications (intended use).
• Any use beyond this normal use is considered non-conforming. Manufacturer is not liable for damage
resulting from such non-conforming use, the sole liability for damage from non-conforming use is with the
user.
• Intended use also includes compliance with the manufacturer’s operating, maintenance and service
instructions.
• The BAUER Rainstar may be used and operated only by persons who are familiar with the device and
aware of the hazards involved.
• All rules for accident prevention as well as any other generally valid specifications and regulations relating
to safety, work medicine and traffic law must be strictly observed.
• Unauthorised modifications on the machine release the manufacturer from liability for damage resulting
therefrom.
2 GENERAL .............................................................................................................................................................3
4 DESCRIPTION ......................................................................................................................................................6
1. In addition to the instructions contained in this manual, all specifications generally valid for safety and
accident prevention must be observed!
2. The warning and instruction signs affixed to the machine give very important instructions for safe operation.
Observing them serves your own personal safety!
3. Never put the machine into operation unless all guards and safety devices are completely mounted and in
their proper working position!
4. Acquaint yourself with all equipment components and controls as well as their respective functions before
starting to work. It is too late when the device is already running!
5. The operator’s clothes should fit tightly. Avoid wearing loose clothes!
6. When handling slurry always keep in mind that the gasses produced are highly toxic and extremely explosive
in combination with oxygen. Therefore, open fires, light tests, sparking and smoking are strictly forbidden!
7. Utmost care is required with regard to gasses in slurry and dung channels at open valves to the preliminary
pit, before the main pit, or at cross channels. The same applies to mixing and withdrawal points when
mixers or pumps are running!
8. When handling slurry always ensure sufficient ventilation!
9. Keep the machine clean to avoid fire hazards!
Tractor-driven machines
1. Before starting inspect the area around the machine (Children) ! Make sure your view is unrestricted!
2. Riding on the machine during transport is forbidden!
3. Couple the machine according to instructions and fasten it only at the specified points!
4. Be especially careful when coupling the machine to the tractor or uncoupling it!
5. Always adjust the supports in the proper position when coupling or uncoupling the machine (stability)!
6. Always mount balancing weights properly at the points provided!
7. Observe restrictions pertaining to axle load, total weight, and transport dimensions!
8. Inspect and mount all items required for transport such as lighting, warning signals and possible safety
devices!
9. Mounted or trailed machines as well as balancing weights influence road behaviour, steering and braking
capacity. Therefore make sure that proper steering and braking are possible!
10. Consider the projection and/or centrifugal mass of the machine when driving in curves!
11. It is forbidden to stay in the working range of the machine while it is operating !
12. Keep out of the turning and swivelling range of the machine!
13. Only operate hinged hydraulic frames when nobody is in the swivel range!
14. Externally powered machines (e.g. hydraulic) bear a crushing and shearing hazard!
15. Nobody is allowed between the tractor and the implement unless the tractor is secured by the parking brake
and /or wedges under the wheels!
16. Hinged supports must always be folded up and secured before driving away!
17. Secure the machine and the tractor against rolling!
Tractor-mounted machines
1. Before a machine is linked to or detached from the three-point linkage, the control device must be shifted to a
position in which unintentional lifting or lowering is impossible!
2. When using the three-point linkage the linkage parameters of both tractor and attached machine must
correspond, if not, they have to be matched accordingly!
3. The three-point linkage bears crushing and shearing hazards!
4. When operating the external control of the three-point linkage never step in-between tractor and the machine!
5. When the machine is in the transport position make sure that the tractor’s links are always properly secured
on the sides.
6. When driving on the road with the machine lifted the control lever must be locked against lowering!
Trailed machines
1. When a machine is coupled to the drawbar make sure that the coupling point provides sufficient flexibility!
1. It is not allowed to use any other types of PTO drive shafts except the ones prescribed by the manufacturer!
2. Drive-shaft guard tube and guard cone as well as the PTO guard – also on the machine side - must be
mounted and in good working order!
3. When using a PTO drive shaft always observe the specified overlap in transport and working position!
4. Never connect or disconnect the PTO drive shaft unless the PTO is stopped, the engine turned off, and
the ignition key pulled out!
5. Make sure the drive shaft is always connected and secured properly!
6. Attach the safety chain to keep the drive shaft guard from rotating with the shaft!
7. Before you turn on the PTO make sure that the selected tractor PTO speed corresponds with the
permissible implement speed!
8. Before starting the PTO make sure that nobody is standing in the danger zone of the machine!
9. Never turn on the PTO when the engine is turned off or during a transport drive!
10. When working with the PTO nobody is allowed near the turning PTO or drive shaft!
11. Warning! The PTO shaft may continue turning due to its centrifugal mass after the PTO has been turned
off! Keep clear of the machine during this time and do not touch until the PTO shaft stands absolutely
still!
12. For cleaning, greasing, or adjusting the PTO driven implement or drive shaft, PTO and engine must be
switched off and the ignition key pulled out!
13. Place the disconnected drive shaft on the provided support!
14. When drive shaft has been removed put the guard on the PTO shaft!
15. If a defect occurs repair it immediately before starting to work with the machine!
Hydraulic system
Electric-driven implements
1. All work beyond normal maintenance of the implement should be performed only by a professional electrician!
2. Defective or broken plugs and sockets must be replaced by a professional electrician!
3. Never pull a plug out of the socket at the flexible electric cord!
4. Extension cables for power supply should be used only temporarily! Never use such lines permanently as
a substitute for the required fixed installations!
5. Flexible lines laid across traffic areas on the farm must have at least 5 m ground clearance!
6. Always turn off the power supply before you do any work on the machine!
7. Check all electric lines for visible defects before you put the machine into operation! Replace defective
cables and do not start the machine before that!
8. Never use electric-driven implements in damp situations or locations exposed to fire hazard unless they
are adequately protected against moisture and dust!
9. Covering electric motors may cause heat concentration with high temperatures which could destroy the
operating equipment and cause fires!
1. Because of the slurry gasses produced in the lines, no slurry is allowed to remain in closed pipelines –
bursting hazard!
2. Lay the pipelines with sufficient inclination and make sure that the selected closing order of valves allows all
lines to be drained completely!
3. Protect the valves against unauthorised handling!
4. If a valve gets jammed do not apply force! Use only the operating levers supplied with the implement!
5. Observe the permissible maximum operating pressure of valves and pipelines when pumps are operated!
6. Service only when the tanks are empty!
Maintenance
1. Never perform any maintenance, service or cleaning work or fault elimination steps unless the drive is turned
off and the engine is standing still!
2. Check proper fit of all nuts and bolts regularly and tighten them, if necessary.
3. If maintenance work is required on the lifted machine always secure it by means of appropriate supports!
4. When exchanging tools with cutting edges always use proper tools and wear safe protective gloves.
5. Dispose of oil, grease and filters according to local laws and regulations!
6. Always turn off power before working on the electric system!
7. Before electric welding on the tractor and mounted machines the generator and battery cables must be
disconnected!
8. Spare parts must meet manufacturer’s minimum technical specifications! This is the case for instance with
original spare parts for instance!
2 GENERAL
BAUER products are designed and manufactured carefully, subject to a system of continuous quality control.
BAUER Rainstar models E 11, E 21, E 31, E 41, E 51 are turbine-driven machines designed for fully mechanised
and labour-saving irrigation. Individual pipe sets are no longer laid down by hand; system set-up, repositioning,
and operation are all done with the tractor only.
BAUER Rainstar is a universal machine suitable of covering fields of varying lengths and widths. There is no
need for supervision while the system is operating.
Strict observance of all operating and service instructions in this manual is the basic prerequisite for many years of
trouble-free operation. Therefore please make sure that all operators on your staff are familiar with the instructions
given in this manual.
The model number as well as the serial number (Vehicle identification number) are stamped into the nameplate.
In addition, the serial number is stamped into the frame of the undercarriage. Please state these data in all your
inquiries, correspondence, warranty matters and parts orders.
4. Never service or set any part of the system (except speed settings) while it is operating.
5. Keep clear of all moving parts.
6. Never expose any moving parts by removing protective elements.
7. Keep a safe distance from the sprinkler during operation.
8. Be careful in case of high connecting pressure!
9. Make sure that the water jet from spray nozzles does not hit public roads.
10. The Rainstar licensed for transport in agricultural operation only. For transportation on public roads all
applicable traffic requirements must be strictly adhered to.
WARNING! For safety reasons it is not allowed to transport the Rainstar by pulling it with a fork-
type drawbar (OPTIONAL) and the toolbar!
11. When loading the machine on a trailer note that the water remaining in the pipe shifts the system’s centre
of gravity upward.
12. When driving in curves with the Rainstar loaded on a trailer the permissible maximum driving speed is
considerably reduced dependent on the position of the Rainstar’s centre of gravity!
13. Always ensure that the locks and stops are secured according to the machine’s general conditions for
transport.
14. Before starting to irrigate near electric power lines you should contact your local power supply company
regarding safe distances that have to be allowed.
15. Maximum permissible speed: 10 km/h
Running direction
The indicated safety distances in the above chart are valid for a nozzle diameter of 26 mm or 36 mm at an operating pressure
of 5 bar. For higher operating pressures the safety distances have to be increased by 2 m. The safety distances are not
valid when normed jet pipes, like they are used by fire brigades, are being used.
When applying polluted water or slurry, note that a conductive layer can build up on the insulators. Therefore do not spray
on the insulators.! Flashovers and insulator damage can otherwise cause power failure.
If metal sprinkler pipes are laid parallel to a high voltage power line, this can lead, even without irrigating, to a perceptible
contact voltage because of the electric influence. Touching the pipes is not dangerous, but can be unpleasant and painful.
This is why it should be avoided to lay metal pipes parallel to high voltage lines or only over the shortest distances possible.
When using synthetic pipes, you will not encounter any of these problems.
Note ! Do not put pipe line pieces into a vertical position in the range of high voltage lines ! Only transport them
horizontally
WARNING! Never remove the drive cover before you have turned off the water supply to the
machine and slackened the stretched PE-pipe.
To slacken the stretched PE-pipe move the gear shift lever downward carefully (see proper procedure on
page13).
A winding carriage moved by a helically grooved spindle ensures that the PE-pipe is wound up properly on all
layers. To keep the retraction speed constant on all layers independent of the pipe length still lying on the field,
the Rainstar is equipped with an ECOSTAR 4000 S.
At the end of the irrigation strip the automatic drive shut-off is actuated by rods.
If the machine is equipped with an overpressure-actuated shut-off valve the water supply to the machine is shut
off simultaneously.
If a low-pressure operated shut-off valve is mounted, the pumping unit is shut off.
After shut-off the rear hydraulic machine supports can be withdrawn. In doing so the cart is raised automatically
into the transport position. Without any further preparations the Rainstar can be transported to its next setting-up
position immediately. Pull off or lay down the PE-pipe again, connect the water supply, and the machine is ready
for the next run.
When driving on public roads the reel must be turned into the driving direction and secured with the lock bolt. The
PE-pipe must be fully wound up on the reel and the cart lifted. The jack and both rear machine supports must be
withdrawn to their uppermost position..
On public roads the drawbar and coupling ring must be hitched to the tractor’s yoke and secured with the pin.. The
maximum permissible driving speed of 10 km/h must be observed. For increased safety against overturning in
curves we recommend to set the maximum possible track width.
On principle, it is possible to transport the machine between hydrants in the field with the cart lifted on the side. In
this configuration the driving speed must always be adapted to the existing conditions and should never exceed 5
km/h. You must also take into consideration that this type of transport requires a wider driving lane.
Tighten the wheel nuts before the first operation and check the tires for the specified pressure (see technical
Data).
Tighten also the connecting bolts, the connection of the turntable side member on the undercarriage, the
ball race on the undercarriage, and the fastening of the hitch eye, according to the “Service and Maintenance“
table.
Note: If you use a blow-out device, the stop valve has to be mounted between cart flange and sprinkler
pendulum tube.
The number of weights required depends on cart track width setting, nozzle diameter, and nozzle pressure.
Note: When using an asymmetric wheel cart, additional 2 weights have to be mounted on the wheel
carrier opposite the inlet (PE pipe) in addition to the weights specified above!
Set the sector on the wide-range sprinkler (ar. 220° for full
track width). Further instructions see in manual for sprinkler.
The VARI-ANGLE can be adjusted to the existing wind
conditions by adapting the trajectory angle.
When positioning the Rainstar make sure that the machine’s vertical axis of rotation is in the middle
of the driving lane or centered between two crop rows.
For lateral pull-off remove the lock bolt, turn the reel into the
direction of the driving lane and secure it again with the lock
bolt.
The standard Rainstar equipment does not include a control unit (Optional). After
WARNING! coupling the hoses the tractor’s hydraulic system for extending or retracting the
supports must therefore be changed over accordingly. If this is not possible, you
have to exchange the two hoses.
For maximum stability the machine supports should be fully extended to their end position.
.
WARNING! During this procedure the operator’s position should be outside the supports.
On very hard soil the supports have to be lowered or extended into holes dug into the ground for this purpose.
Then depressurise the tractor’s hydraulic system and uncouple the hydraulic hoses.
Brake release
PE-pipe pull-off
Traktor rewind
Do not stop abruptly, but slow down gradually at an intermediate stop or at the end of the pull-off.
CAUTION! If the PE-pipe is to be pulled off in a wide bow, make sure that it is pulled in a straight
line of about 80 to 100 m first (90° angle to the reel) and then in a wide bow.
If the PE-pipe has been exposed to the sun for a longer period or if its surface
WARNING! temperature rises above 35 °C you must let water run through the pipe to cool it off
before the unwinding or retraction procedure.
TVR 60
1 8 -- 20 m/ h
2 16 -- 32 m/ h
3 28 -- 50 m/ h
4 > 45 m/ h
Before system start-up, the control range of the TVR 60 turbine must be limited according to the following chart.
Please take discharge and retraction speed from the performance chart.
If discharge or retraction speed change substantially, the limiting bolt must be readjusted.
When the full operating pressure has been reached and clear
water is discharged at the sprinkler’s nozzle in a full jet without
air bubbles, push the gear shift lever to the “PE-pipe
retraction“ position.
CAUTION! Switching into the gear speeds 1 to 4 is only possible when the turbine is rotating!
CAUTION! Move the gear shift lever into the desired position and set back the shut-off lever to
the “PE-pipe retraction“ position.
Further procedure:
At the end of the irrigation run the drive is shut off by rods.
In case the Rainstar gets misaligned or pulled aslant during PE-pipe rewind it has to be realigned. For this
purpose you need to slacken the PE-pipe first.
Proper procedure:
1. Close the water supply to the Rainstar. The PE-pipe slackens only partially by the turbine that acts like a
hydraulic brake
2. Pull the shut-off lever into the shut-off position and push
it downward slowly and carefully...
The four-speed gearbox adapts perfectly to existing operating conditions. As a result the following retraction
speeds [m/h] can be reached:
.
TVR 60
1 8 -- 20 m/h
2 16 -- 32 m/h
3 28 -- 50 m/h
4 > 45 m/h
Removal of the drive cover for service is only permitted when the PE-pipe is
WARNING! completely slack and the water supply turned off !
The gear shift lever must be moved to the shut-off position ! This shut-off position
must also be used for transporting the machine on the road !
or shut-off position
WARNING! If the shut-off lever is in the shut-off position, press the lever down slowly and
carefully so that the band brake is released and the PE-pipe slackens (see also page
13).
If required, you can rewind the PE-pipe also with the tractors
PTO system
A spring presses the gear shift lever into a locking recess. In this position the band brake is slightly loosened
and does not have any brake action during the wind-up.
Winding up the PE-pipe with the PTO will become necessary if there is no need to continue irrigating due to
natural rainfall.
BAUER 4000 S
6.1 GENERAL
BAUER ECOSTAR 4000 S allows you to operate your irrigation machine with ease at the touch of a
button.
An illuminated four-line display provides comprehensive indication of the machine’s operational status.
Through permanent comparison of set-point and actual value of the retraction speed you can administer your
crops precisely the precipitation they need.
ECOSTAR 4000 S consists of the electronic box, a cable harness with the connected sensors for PE-pipe
length, retraction speed and shut-off as well as connections for battery, solar panel, and turbine regulating
motor.
Connections are also provided for installing both a shut-off valve and a pressure switch (both optional
equipment).
The electronic system of ECOSTAR 4000 S is rigidly built and has been tested under different climatic
conditions.
If problems still occur it is advisable to exchange the complete electronic box.
If a sensor is defective, you can replace the sensor only.
Always disconnect the battery before carrying out welding work and repairs on the
WARNING! Rainstar!
Because of the standard solar panel it is not necessary to charge the battery during the irrigation season. If you
have to charge it nevertheless, the maximum charging current should not exceed 2 amperes.
ECOSTAR 4000 S keeps the pre-selected retraction speed on a constant level throughout the pipe retraction.
Due to simple key assignment, operator control requirements are very low.
Normally, ECOSTAR 4000 S is in the energy-saving mode without displaying information.
Simply press the “POWER ON“ or “PE-pipe retraction” key to activate the electronic system and turn on the
background illumination with the standard display.
The first line indicates the desired retraction speed; it can be altered any time also while the system is irrigating
(pre-setting 30 m/h).
The second line indicates the time (in hours and minutes) remaining until the irrigation run is finished, including
pre and post irrigation. This time setting can be read off any time during the irrigation run.
The third line shows the length of PE-pipe laid down on the ground.
It is possible to enter this length by hand, for instance after a metering error (locate the cause and exchange the
length sensor for instance) – for this purpose see Parameter Sheet no. 1, program constant no. 07.
The fourth line shows pre and post irrigation time in minutes. If the number is blinking, it means that the system
is currently running on pre or post irrigation.
If the display shows LOW BAT instead of the speed the battery voltage is lower than 11.8 V. Charge the battery
th
with a power supply unit or exchange the battery. (Check if solar panel charges properly, see 4 line of test
menu).
Test 1
Stop - sensor
Speed – sensor
MOTOR 1 MOTOR 2
If the symbol appears on the display it means that this function is switched on.
The first line on the left indicates the menu status „Test 2“
The first line on the right shows if - with a pressure sensor mounted - the pressure at the machine is sufficient.
The symbol appears when pressure rises above the minimum pressure at which the pressure switch is set.
The machine will operate only with sufficient pressure or stop in case the pressure is lower than the set minimum
pressure.
The second line shows if the stop sensor is activated, the symbol is displayed if the stop sensor is activated
(operating position, the magnet sits 2 – 5 mm close to the sensor)
The third line shows if the speed sensors are in proper working order. The symbol appears when a
magnet activates the two speed sensors at the turning of the magnet disk.
The fourth line shows if the motors 1 and 2 have been switched off after having reached their mechanical stop.
If the symbol appears and one motor has not reached its end position there is a blockage inside the turbine
(MOTOR 1) or the shut-off valve ( MOTOR 2 ).
The motor is turned off when the current input rises above 4.7 amperes, the symbol appears.
If the display shows MOTOR 1 blinking, it means that the regulating motor is currently running.
MOTOR 1
During this motor running time (max. 26 seconds), it is impossible to make entries on the keyboard.
If the display shows a blinking MOTOR 2, it means that the shut-off motor for the shut-off valve is currently
running.
MOTOR 2
It is impossible to activate keys on the display while the motor is running. The motor runs for max. 26 seconds.
POWER OFF
The electronic system is activated again when the PROG/POWER ON key is pressed or the PE-
pipe pulled off.
The battery is only charged while the electronic system is active. No charging takes place in the stand-by mode.
Summary:
Take over the retraction speed from the previous run or make a new entry.
FURTHER INSTRUCTIONS
After a longer standstill the electronic system of ECOSTAR 4000 S is in the stand-by mode.
Pulling off or laying down of the PE-pipe activates the electronic system and the length of the pulled off or laid
down pipe is counted.
TIME 10 : 00
LENGTH 300 m
First the speed changes by 0.1 m/h step by step, than the speed changes by 1.0 m in steps of 10.
The speed can be changed at any time while the machine is running.
The time remaining until the end of the run is always adjusted automatically, too.
It is impossible to change the speed while a turbine regulating or shut-off valve motor is operating. The display
shows MOTOR 1 or MOTOR 2.
Along with the speed change, the time pertaining to the speed setting it is also changed.
TIME 15 : 00
LENGTH 300 m
Caution! When setting the speed you must check on the speed that can actually be reached
according to the test window (push test key once).
In case of deviation you have to reduce the set speed to the speed actually possible.
Pre and post irrigation time are pre-programmed. ECOSTAR 4000 S calculates them as being 8 times the time
required for covering 1 m at the actual speed.
TIME 15 : 48
LENGTH 300 m
If you press the “START-RESET” key in the pr-irrigation mode, the pre-irrigation function is
cancelled.
Before activating the pre or post irrigation mode the PE-pipe should be pulled off (the shut-off frame and thus
the shut-off sensor should be in the operating mode) and the START-RESET button should have been pressed.
If the post-irrigation mode is activated the machine stops 8 m before the end of the run for the post-irrigation
time. This value is pre-adjusted and can be changed in the program constant no. 6 – see Parameter Sheet 1 :
Constants.
If you push START – RESET in the post irrigation mode, the post irrigation function is cancelled.
6.3.3. START
When the PE-pipe is pulled off and the desired speed is set on the device, push the button to start irrigating.
The turbine can only start if the shut-off frame and thus also the shut-off sensor are in the operating state (PE-
pipe pulled off).
If the START–RESET key is pressed the turbine flap closes, the toothed segment on the regulating motor turns
away from the reel and the shut-off valve (if mounted - optional) opens.
6.3.4. MONITORING
At the end of the run the shut-off sensor is activated through shut-off frame and shut-off rods.
That way the turbine stops and the shut-off valve - overpressure - slowly closes and remains in this position
until the next run.
If the Rainstar is connected to a hydrant the water pressure existing after closing
of the hydrant can be released by pressing the START-RESET key.
The irrigation cycle can be stopped at any time by pressing the STOP key.
The turbine flap opens (the turbine stops), the overpressure shut-off valve closes or the low-pressure shut-off
valve opens.
Thereby the laid-down PE-pipe length remains saved in the system. It is only reset to 000 if the shut-off sensor
(shut-off position) is activated.
WARNING !
If the „STOP“ button is actuated during the retraction on a machine, that does not have a shut-off valve, the
retraction stops, the gun, though, continues operating. To prevent a local over-irrigation around the gun, the
machine should operate only for a short period of time without retraction, if required, and then put into operation
again by pressing the START button.!!
WARNING !
When the machine data at pos. 12 is set „0000“, the retraction stops only for a short period of time
when actuating the „STOP“ button. After a few seconds the retraction starts automatically again.
WARNING: When working on the machine always turn off the entire drive completely !!
If the Rainstar, after having been positioned for the run, is supposed to start-up only after the required pressure
has built up in the supply line (pressure start), a pressure switch must be installed.
If such a switch is available, the monitoring system will also interrupt the irrigation cycle in case of low water
pressure. As soon as the pressure returns to standard the run is continued.
CAUTION: The pressure switch always has to be used in connection with an overpressure shut-off valve. !!
Charge.
Battery defective.
Exchange.
Cover solar panel, disconnect the
battery and hook it up again
(Reset).
Electronic system defective. Electronic fault.
Call customer service.
Exchange the electronic box
Turn off water supply.
Overwinding fault. Slacken PE-pipe.
Readjust the machine.
Premature machine shut-off Put the shut-off frame into the
Shut-off frame has been operating position
activated unintentionally. enter laid-down pipe length
and press “START”
Increase pressure or enter
The retraction speed is not Low pressure in supply line
retraction speed according to the
reached. or pump station
performance chart
WARNING!
If the setting is in US units, you have to enter 11 [f/h] instead of 11,1 [m/h].
Immediately press the “PROGRAM” key 3 x (three times) in order to get access to program
constant 01 (see Parameter sheet no. 1).
Press the PROGRAM key for a short while again to select the program constants 01 to 09 – see parameter
sheet no.1.
.
Use the cursor keys to change the values of the constants as required.
If you press the TEST key the program returns to the standard display and the changed constants are saved.
If the TEST key is not pressed the program will return to the standard display after 1 minute and the changes are
not saved.
The constants remain saved even if the battery is disconnected for a longer period of time.
In the program constant 09 with the value 111 you have access to the machine data.
By pressing the PROGRAM key you enter the machine data mode.
See Parameter Sheet No. 2.
Press the PROGRAM key for a short while again to select machine data numbers 00 – 18 .
.
Now you can use the cursor keys to change values according to actual requirements.
If you press the TEST key the program returns to the standard display and the changed machine data
are saved.
6.5.1. BATTERY
The standard factory equipment includes a battery with 12 volts and 6,5 ampere-hours.
Due to the standard solar panel it is not necessary to charge the battery during the irrigation season. The battery
should be newly charged every 6 months at a charging voltage of max.
2 amperes. (Please observe the enclosed service and maintenance instructions).
When you connect the battery the display shortly shows VERSION 4.1 and then the standard display comes up.
To reach a long life of the dry battery (LC-R 127R2PG 7,2 Ah/20 HR) used on the ECOSTAR, it is important to
follow certain guidelines when storing it for a longer period of time and when charging it.
When using the battery on the ECOSTAR during the operation, there is no need for any special pre-cautions,
because it get re-charged through the solar panel.
1. Every RAINSTAR irrigation machine delivered by BAUER, that is equipped with the electronic control
ECOSTAR, comes with a fully charged battery, ready to be used.
The solar panel, though, is covered and not hooked up to the battery. If there is a longer period of time
between delivery and first operation, follow the maintenance steps (as pointed out below)
This should also be observed, when a battery is stored for a longer period of time as a spare part.
2. If the RAINSTAR is not operating for a longer period of time, e.g. out of the irrigation season, disconnect and
take off the battery.
3. Store the battery fully charged, separate from any conducting material and unexposed to sun.
If the battery is stored uncharged for a longer period of time, it will not reach its full capacity again when re-
charging it.
4. The optimum storage temperature is between 0° and +25°.
A stored battery discharges itself also. Therefore, re-charge at the following intervals:
5. You will need a low humidity in the storage room ( 55%+/- 30% ) to avoid a corrosion of the poles.
6. Avoid that the battery gets completely discharged. In that case, the battery can reach its full capacity again,
but, if discharged completely repeatedly, its lifetime will be reduced.
7. Keep the batteries clean. To clean them, you can use a dry towel. If necessary, soak them in water or
alcohol. Do not use oil, gas or dilutents.
8. In no case, you should take batteries apart, because they contain acid and can cause serious burns.
9. Do not short-circuit batteries, because this may damage them.
10. Charging the battery should be done with a charging current that does not exceed 2,0 A. If a battery is
empty, it takes around 7 hours to re-charge it completely.
Devices to monitor the battery capacity and chargers with intelligent (self-regulating) charging function,
enable a precise analysis and a controlled charging of the battery.
The regulating motor closes (the segment turns towards the limit bolt)
The overpressure shut-off valve is opened.
The low-pressure shut-off valve remains closed.
The regulating motor opens the turbine (the segment turns away from the limit bolt)
The overpressure shut-off valve closes.
The low-pressure shut-off valve is opened.
The magnet disk with 4 magnets is mounted on the input shaft of the gearbox and turns clockwise during pull-
off.
Because of the clock-wise turn of the magnet disc, the display for the laid-down pipe must count from 0 m rising.
If the distance meter counts into the opposite direction, the speed sensor must be turned around, so that the
cable connection is pointing upward. Distance 2 – 5 mm between double sensor and magnet disc.
Speed sensor
6.6.1 LIMITER FOR TURBINE REGULATING FLAP WITH ECOSTAR 4000S AND 4200
See item 6.5. The regulating range of the turbine regulating flap has to be adjusted to the respective flow rate. If
the limiter is not ajdusted correctly, the regulation at the turbine might not function any more, i.e. that the PE pipe
retraction is at a maximum speed.
If the flow rate is reduced considerably, the limiting bolt must be adjusted again because otherwise the retraction
speeds according to the performance chart cannot be reached.
The flow rate can be drawn from the performance chart affixed on the machine right below the nozzle size used.
5. Checking the setting of the limiting bolt of the toothed segment of the regulating flap according to
the values on the setting chart sticker.
During the first start-up and at the start of the season, but also during operation, error messages or
maloperationin may occur in connection with the electronic system or the sensors connected as well as
problems resulting from wrong operation.
In most cases, the error can be detected and eliminated very quickly by a systematic system check-up on the
basis of the following checklist.
This checklist serves as a supplement to the detailed operating manual for ECOSTAR 4000 S and 4200
After checking up the device according to the separate SHORT CHECK-LIST the handling instructions can be
taken from the table below.
Note: In some cases, operation differs due to different control keys of the models 4000 S and
4200. However, special reference is made at the respective points.
Pos.
Note !
•
If the solar panel is not covered up, the display may show a
voltage read-out even if the battery is empty, or it may even Charge or
pretend sufficient battery charge in sunshine. replace the
The electric charge, however, is not sufficient for system battery
operation under these circumstances!
2. If the battery voltage (now uninfluenced by the covered-up
solar panel) is lower than 12 V, power supply is not sufficient for
system operation.
2. No read-out Check battery, cable connections, and fuse !
on display 1. Test battery voltage, battery is empty Charge or
replace battery.
2. The connecting cables between battery and ECOSTAR are not Check
connected or do not make contact. connections
and contacts.
3. The fuse is defective.
The fuse is located inside the electronic box where there is also a Replace fuse.
spare fuse.
Notes !
• When checking the contacts make sure that the cables are
connected correctly:
„+“ terminal = brown wire, „-“ terminal = blue wire.
• The solar panel should be covered up also while connecting and
disconnecting the battery, and as long as the battery is
disconnected because otherwise the system could display errors.
• The stored machine data are preserved when the battery is
disconnected.
• When re-connecting the battery, never confuse the “Plus” and
“Minus” terminals because this would short-circuit the system and
trip the fuse, or possibly damage the electronic system.
ECOSTAR 4000S / 4200 feature a pre and post irrigation function in order to correct uneven precipitation at the
beginning and at the end of the field . The rain height at both the beginning (pre-irrigation) and end ( post
irrigation) of the field is achieved by stopping the retraction of the sprinkler cart for a predetermined length of
time The time of pre and post irrigation is set on the ECOSTAR by means of the program constants 01 and 02
in parameter sheet no. 1. The factory setting is program constant 08.
This factor establishes a relation between sprinkler retraction speed and pre as well as post irrigation. The set
factor can be changed – as a result pre and post irrigation times change.
The table below shows pre and post irrigation time in minutes (rounded) at various setting factors. .
8. WINDING MECHANISM
The winding mechanism operates synchronously with the
winding or unwinding of the PE-pipe. Starting from the reel it
is operated through a chain and the helically grooved spindle
transporting the winding carriage of the PE-pipe. The winding
mechanism ensures that the PE-pipe is properly guided
winding for winding. When you put the machine into operation
for the first time, pull off the full length of the PE-pipe to let it
take a circular shape under pressure and eliminate ovality.
This step is essential for trouble-free operation of the winding
mechanism.
10. CART
The high construction of both symmetric and asymmetric
wheel carts provides maximum crop protection (Asymmetric
wheel cart OPTIONAL). With infinitely variable track width
the carts adapt to any crop row spacing. The width is
symmetrically adjusted with the frame support member.
Depending on the type of sprinkler used, the nozzle height of the mounted sprinkler ranges between 1960 and
2120 mm.
At the end of the retraction, when the cart moves up to the machine it is slightly hoisted on the PE-pipe side.
Owing to its pendulous mounting (self-balancing assembly) the sprinkler is not tilted and always remains in the
optimum position regarding distance of throw and distribution uniformity. This pendulous mounting assembly
compensates also slopes in the terrain in longitudinal direction.
CAUTION! The low pressure shut-off valve option can only be used if only one irrigation machine
is fed by the pumping unit. If several machines are fed simultaneously by one
pumping unit this low-pressure or underpressure shut-off valve cannot be used !
OVERPRESSURE SHUT-OFF
In areas, where frost is likely in winter after the irrigation season, the machine must be drained in time. werden.
A compressor with a minimum air capacity of 5000 l/min at 1,5 bar overpressure is best suited for this purpose.
Connect the compressor to the inlet of the machine For blowing out the water the PE-pipe should not be pulled
off. It can stay on the reel.
In most cases, winding up the empty PE-pipe after the draining will cause extreme ovality and faulty winding.
The small amount of water remaining in the PE-pipe after the draining (approx. 30 to 50 % of the volume) will not
do any harm.
Turn out the drain plug on the bottom of the TVR 60 turbine. We recommend to turn it in again only when you
start up the machine again at the beginning of the next season. Clean the Rainstar and regrease all appropriate
points. The machine should preferably be stored in a roofed shelter where it is protected from direct exposure to
the weather.
Note the following instructions to ensure proper function of the blow-out unit:
1. The blow-out must be performed before further transport of the machine to ensure that no water is drained
from the PE pipe.
If parts of the PE-pipe have run empty and air bubbles are enclosed in the pipe,
CAUTION!
the blow-out will not work !
2. If you use an electric shut-off valve, press the menu button „START“ so that the valve opens.
3. Connect a drain pipe at the inlet of the machine to avoid soaking the machine’s standing position.
If you use the supply hose (7) for draining, make sure that the hose is not
CAUTION!
kinked and the water can run off freely.
PROCEDURE:
The PE pipe is wound up on the reel, the cart is just before the shut-off position, take off the end cap (with bore
and baffle plate) from the „garage“ (1).
Press the plastic ball in the “garage“ down by hand or with a piece of wood until the ball gets to lie in the straight
horizontal pipe (2) behind the outlet to the sprinkler.
Connect the pipe bend 90° (4) to the coupling „garage“ (1) and the compressor hose (5) to the pipe bend (4)
and the compressor (6).
The PE pipe can now be drained with the help of the compressor.
Technical specifications of the compressor:
• Operating pressure: 1,5 bar sufficient
• Air capacity: minimum 5000 litres at 1,5 bar
It does not take more than 5 to 8 minutes to drain the PE-pipe. If the blow-out takes longer, there are already air
bubbles in the pipe that prevent further draining.
Remove the fittings with the hose and couple the end cap with the baffle plate.
The blow-out ball is in the inlet bend to the reel and the water will carry it back to the „garage“ (at the end of the
horizontal pipe), when you resume irrigation.
Fault Remedy
PE-pipe has run empty. Put the irrigation machine under pressure
again until a full jet without air bubbles is
discharged at the sprinkler.
Kink in the drain hose from the turbine. Lay the hose straight without kinks or connect
a rigid pipe.
Plastic ball not in the correct position. Push down the plastic ball far enough to place
it in the straight horizontal pipe
110mm : : 100mm
120mm : : 110mm
125mm : : 125mm
CAUTION! The end cap on the branch pipe of the horizontal pipe („“Garage“ of the plastic ball)
must have a vent bore through which the branch pipe is deaerated when the ball is
pressed to the cart by the water pressure from the turbine side.
Then the plastic ball will park properly in the „“garage“ during irrigation. If this vent
bore is missing, the plastic ball remains in the area of the horizontal pipe during
irrigation and may cause considerable pressure loss on account of the reduced
cross section..
We cannot emphasise often enough that proper service at the right time is essential for the operating reliability
and service life of a machine. At the end of every irrigation season the Rainstar should be thoroughly checked
and cleaned, and all parts greased carefully.
6. Change-speed gear Change oil for first time after 500 OMALA OIL 220
service hours and then every
500 to 800 hours or at least once gear lubricant oil
a year
T-Model E-Model
2 1 2 1
The PE-pipe cannot be pulled Incorrect gear shift lever position. Put it into the pull-off position.
off.
PE-pipe retraction stops before Turbine blocked by a foreign Remove the foreign body.
the final shut-off is actuated body.
The final shut-off is activated but Values for shut-off valve Adjust the settings according to
the shut-off valve does not activation are not set correctly. the manual.
close.
The reel overwinds or the Tractor stopped abruptly. Slow down gradually.
windings become loose when
the PE-pipe is pulled off.
The selected retraction speed is Incorrect drive transmission. Select proper gear transmission
not reached
Procedure:
Move the shut-off lever (9) to the “PE-pipe retraction“ position.
Turn the V-belt pulley (10) - the PTO shaft (11) rotates too!.
Shift the shut-off lever (9) slowly to the “0“ position.
The spring (12) presses the shut-off lever (9) upward along the incline of the shifting gate and thus into the
recess in the gearbox.
Tighten the hex. nuts (2) of the band brake until the bolt thread of the brake band (1) protrudes B = 13 mm/0.51
inch. Lock the hex. nuts (2).
Hex. nut (3) is tightened until the spring (5) is pre-tensioned at A = 22mm/0.86 inches , lock with nut (4).
Turn the hex. nuts (6) on the threaded rod (7) apart until the spacing between the brake lever (13) and the nut
(4) is at C =2 mm/0.08 inch. Lock the hex. nut (6).shifting gate (8) and the shut-off lever (9) is about 4 to 5 mm.
Secure the hex. nuts (6).
16.4. INSPECTING THE BAND BRAKE FOR RELEASE OF THE BRAKE BAND
In this position the brake band must be slightly lifted off the brake disk. This prevents the brake band from
sticking to the brake disk.
In the operating position the spacing between the shut-off frame (13) and the reel (17) is x = 25 mm/1 inch
Set the shut-off frame (13) in the shut-off position at X mm from the reel (17) (see chart). Put the shut-off lever
(9) into the shut-off position.
Adjust the hex. nut (15) on the control lever (16) to the bracket (14) of the shut-off frame.
Step 1:
Pull off the PE pipe and adjust the connecting bend (7) in a vertical position pointing down (except for E 51
PE-Pipe ∅ 120, inner width of reel 1600 mm, α=80°).
Step 3:
Fasten the two guide bars (4 and 5) symmetrically at distance X 2 on the guide part (3).
Mount the roller bracket (6) with the roller.
Step 4:
Move the guide part (3) of the winding carriage to the outermost reversing point of the groove on the right by
turning the helically grooved spindle.
Loosen both pillow blocks. ( Screws M12 )
Check the connection of pillow block – helically grooved spindle, if safety screws ( grub screw ) are tightened.
The pillow block must rest on the shaft shoulder of the helically grooved spindle (2).
Shift the bearing and the helically grooved spindle (2) until value X 1 is reached, fasten the right pillow block.
PE – pipe ∅ X1 X2
90 E11,E21 10 mm / 0,39 inch 110 mm / 4,33 inch
100 E11,E21,E31,E41 17 mm / 0,66 inch 126 mm / 4,96 inch
110 E11 14 mm / 0,55 inch 140 mm / 5,5 inch
110 E21,E31 20 mm / 0,78 inch 140 mm / 5,5 inch
110 E41 24 mm / 0,94 inch 146 mm / 5,74 inch
110 E51 28 mm / 1,1 inch 146 mm / 5,74 inch
120 E21 28 mm / 1,1 inch 150 mm / 5,9 inch
120 E41 18 mm / 0,7 inch 150 mm / 5,9 inch
120 E51 28 mm / 1,1 inch 150 mm / 5,9 inch
125 E31,E41 24 mm / 0,94 inch 160 mm / 6,3 inch
125 E51 30 mm / 1,18 inch 160 mm / 6,3 inch
140 E41,E51 20 mm / 0,78 inch 170 mm / 6,7 inch
Step 5:
Align the right guide bar by turning the helically grooved spindle to the inner reel side wall at value X 3.
(see chart)
PE – pipe ∅ X3 α
90 E11,E21 0 0°
100 E11,E21,E31,E41 0 0°
110 E11 0 0°
110 E21,E31 0 0°
110 E41 0 0°
110 E51 0 0°
120 E21 0 0°
120 E41 0 0°
*120 E51 0 80°
**120 E51 0 0°
125 E31,E41 0 0°
125 E51 0 0°
140 E41,E51 0 0°
*E 51 – Inner width of reel 1600 mm
** E 51 – Inner width of reel 1570 mm
The right and left machine supports are shipped in a wooden crate.
Mount the two anchoring shields (1), which are shipped loose, on both support legs according to the drawing
with the lock bolt (3). Fasten the lower support brace (4) with the bolt (2).
In special situations, e.g. if the path on which the Rainstar sits is slightly inclined, the anchoring shield can be
mounted extended by 120 mm.
The new design of the anchoring shield (1) with a round connection part allows to swivel it by 180 degree by
taking off the lock bolt (3). This means a higher ground clearance, which makes transportation easier.
Before mounting the right support, take off the cover (15).
Put the pre-mounted right support leg into engagement with the guide (5) and fasten it to the turntable side frame
(7) with the bolt (6) (per the drawing).
Mount the support lift (8) in the turntable side frame with the bolt, turn up the fork and screw it with the bolt (9).
Mount the cart lift (10) according to the sketch . (Stop brackets pointing upward).
Move the cross beam to 1550 or 1650 mm/61 or 65 inch height, adjust the set screw (11) and secure them.
Mount both square washers (12) on the lower braces (4).
CAUTION! The upper bore hole for E11 , E21 , E31 ; the lower bore hole for E41 , E51
Push the upper brace (13) over the lower brace (4).
Lift the cart lift bracket (10) and screw it with the braces in such a way that it can swivel.
ATTENTION Check setting dimension of cart lift bracket when mounting the machine
Now the hydraulic hoses are coupled with the non-return valve blocks (14).
If the inspection of the hydraulic system shows that the cylinder movements are wrong you must exchange the
hydraulic hoses !
This is also necessary when the moving directions with mounted control valve options do not correspond with
the predefined switching diagrams.
The standard Rainstar outfit includes hydraulic machine supports without a control valve block.
Hydraulic diagram “Control valve block - machine supports + swivel aid “ (OPTION)
Hydraulic diagram “Control valve block – machine supports + jack + swivel aid” (OPTION)
For safety reasons you must handle the hydraulic system with utmost care.
CAUTION!
The rear right support and the cart area are not directly visible from the
operator’s position Therefore no other person is allowed in the immediate
vicinity of the machine !
* Total weight including cart, sprinkler, and 4 sprinkler cart balancing weights.
Information:
Machine height with tandem axle: E11-E21/4W: N + 300mm, E31-E41/4W: N + 280mm, E51: N + 210mm
Machine height with 4-wheel design 4WB: E31/4WB: N + 70mm, E41+E51/4WB: N + 90mm
Always ensure that tire pressure is correct in order to guarantee maximum tire life and safe transport of the
Rainstar!
Note: Minimum track widths with wide tires on E 11 – E 51, E 11/4W - E 51/4W 1 900 mm
EU Declaration of Conformity
We,
herewith declare that in respect of its conception and design and in the types and styles which we market the
machine mentioned below fully corresponds with the relevant fundamental provisions for safety and health
stipulated in the General EU Practices for machinery.
This declaration becomes null and void should any modification be made on the machine without our prior
consent
This range of machines has been developed and manufactured according to the standard:
Technical director
Voitsberg, 18.07.2002