Wind Load Calculation
Wind Load Calculation
DESIGN OF PURLIN
INTRODUCTION & BASIC LOAD CALCULATION
1. GENERAL
This report contains the structural analysis and design of steel structure for Store -1
Analysis & design calculation is done in STAAD.Pro -V8i (Consider IS:800 2007 LSD)
Here Basic Wind Speed 47 m/sec. Detail wind load calculation has done in separate sheet.
Calculation of Wind Load
WIND LOAD CALCULATION ON WALL
Basic wind speed,Vb = 47 Terrain Category - II
K1 = 1.00 K3 = 1
0 - 10 HT 0.135 MT/m²
10 -15 HT 0.149 MT/m²
15 - 20 HT 0.155 MT/m²
20 - 30HT 0.169 MT/m²
Total = 2.688
15 % Extra for Gusset Plate = 0.403
Total = 3.091
Wind Solidity Ratio along wind ,Ø = 3.091 / 20 = 0.155
Force-efficient Cf = 1.840
X-wind
Z-wind
0 - 10 HT 0.135 MT/m²
10 -15 HT 0.149 MT/m²
15 - 20 HT 0.155 MT/m²
20 - 30HT 0.169 MT/m²
Wind udl [t/m] on roof for wind in Z-dirn: Wind udl [t/m] on roof for wind in X-dirn:
Span (m) Internal Pressure(-0.7) Internal Suction(+0.7) Span (m) Internal Pressure(-0.7) Internal Suction(+0.57)
Windward Leeward Windward Leeward Windward Leeward Windward Leeward
1.00 -0.054 0.041 -0.245 -0.15 1.00 -0.013 -0.013 -0.203 -0.203
h (m.) = 4
Cpi = -0.7 Cpi = +0.7 Cpi = -0.7 Cpi = +0.7
w (m.) = 10
DESIGN OF BASE PLATE
Design of Base Plate on grid For all Col.
Maximum compressive force for Node No 2 Load case 500 DL+LL= 7.292 Ton
Maximum tensile force for Node no.3 Load case no. 516 0.9*DL + WL (-) X (CPI
7.897
= +0.7)=
Ton
Maximum Shear force for Node Number 13 Load case 13= 1.441 Ton
Column Size is MB250
The following configuration is considered for base plate design:
W=250
Grade of Conc= M20 M25
Per. Conc. Bearing stress= 90Kg/cm^2
62.5 Dia of bolt Chosen= 16 mm
L=350 Tension capacity of Bolt= 4.60Ton
p= 125 Thickness of base plate = 20 mm
62.5 Thickness of gusset plate = 8 mm
Tension per bolt = 1.97 ton
g= < Bolt capacity, hence OK
125 Stiffner height = 200 mm
Both side fillet weld size in gusset =6 mm
Concrete bearing Pressure = 7.292X100000/350x250= 8.33 kg/cm2 <Per. Conc. Bearing stress=
90Kg/cm^2Kg/cm^2, Hence OK
i)Moment in base plate from concrete bearing pressure for two adjacent side supported panel as per
Moddy's chart for unifrom pressure as per the following =
a/b= 0.413
Moment Co-efficient α = 0.078
50.0mm =a
Moment per unit centimeter width =
=α x 8.33x12.1^2 kg-cm/cm
= 95.13 kg-cm/cm
Bending capacity of base plate per unit cm= 1.2xfyxZe/ϒm0 =
= Mdp = 1672.7 kg-cm/cm
121.0mm =b
>95.13Kg-cm,OK
ii)Moment in base plate from concrete bearing pressure for three adjacent side supported panel as per
Mukhanov's chart for unifrom pressure as per the following =
a1= 121.6mm
a1/d1 = 1.08
Moment Co-efficient α3 = 0.115
Moment per unit centimeter width =
d1= 113.0mm =α x 8.33x11.3^2 kg-cm/cm
= 122.32 kg-cm/cm
Bending capacity of base plate per unit cm= 1.2xfyxZe/ϒm0 =
= Mdp = 1672.7 kg-cm/cm
>122.32Kg-cm,OK
iii) Checking of base plate thickness for bolt tension is calculated considering the angle of dispersion of load from
bolt to base plate is 45o. The load accumulation per side of three side supported panel is calculated first.
Then the stress in base plate per each side is checked with respect to dispersed width.
121.6mm Tension per bolt (T) = 1.97425 ton
Considering the Dispersed length and Tensile force
(T3,L3) per side as (T1,L1),(T2,L2) & (T3,L3) as per the
59.1 figure shown, the followins are evaluated:
50.5mm
L1 = 109.6 mm
(T1,L1)
#######
L2 = 121.55 mm
62.5mm o
45 L3 = 101.00 mm
(T2,L2)
Tensile forces are evaluated based on deflection compatibility at bolt location.The following equations
are solved to get the tensile force induced per side.
T1+T2+T3 = T (Eqn 1)
T1 x(59.1)^3 /(3EL1)=T2 x(62.5)^3 /(3EL2)=T3 x(50.5)^3 /(3EL3)Where E = Modulus of Elasticity =
(Eqn 2) =2X10^5 N/mm2
Hence Bending moment per unit cm in base plate due to T1= 600x5.91/10.96kg-cm/cm= 313.8 Kg-cm
Bending moment in base plate per unit cm due to T2= 500x6.25/12.155kg-cm/cm= 257.1
Bending moment in base plate per unit cm due to T3= 900x5.05/10.1kg-cm/cm= 450.0 Kg-cm
= yxZe/ϒm0 =
Bending capacity of base plate per unit cm width = M dp 1.2xf 1672.7 Kg-cm
The above mements are < Mdp, Hence OK
=20154.80 kg >518.75kg,OK
b) Web Stiffner
200mm 200mm
121.6mm 121.6mm
Shear force in gusset plate = 8.33x121.55x101/100 kg Shear force in gusset plate = 1.7Ton
= 1.02 Ton
Shear capacity of gst. = =20.15 Ton > 1.02 Ton,OK
Shear capacity of gst. = =20.15 Ton
> 1.7 Ton,OK
Check for welding stresses
Maximum shear at face of column from above two conditions= 1.7 Ton
Corresponding bending moment at face of column = 10047 kg-cm
Shear stress in both side fillet weld (τ)= 1.7x10^5/(2x0.7x151x6)kg/cm2 = 134.03 kg/cm2
<1100kg/cm2, OK
Bending stress in tensions in fillet weld (σ) = 10047/31.92 kg/cm2= 314.76 kg/cm2
<1893.7kg/cm2, OK
2 2
Combined stress in fillet weld =√σ +1.8τ 362.5 kg/cm2 <1893.7kg/cm2, OK
14.41 kg/cm2
50mm
(TOC) (TOC)
=100mm 20mm
200
Type -I OR Type-II
Maximum Bending Moment at the bottom of base plate = 1.441x(0.33x100+50)x1000/200 kg-cm = 598 kg-cm
Hence provide Star Shear Key of depth 150mm X200mm wide X 20mm which is butt welded with each other and butt
welded to bottom of base plate
DESIGN OF PURLIN
Design of Purlin
Design Wind Pressure = 135 kg/m2 Dead load of sheeting = 20.1 kg/m2
Pressure Co-efficient = 1.3 Live Load on sheeting = 160 kg/m2
Roof Slope = 1 in 3
Y
z
z
Y
θ WL
DL+LL
Minor axis moment is claculated based on same equation, where the support is counted by no of sag rod support. i.e
Case I: Single span My(span) ==wyLy2/8, (i.e No sag rod or Single central Sagrod support.)
Case II: Double span continious My(supp) ==wyLy2/10, (Two or More equidistance sag rod support)
UDL Load intencity about major (i.e about z axis) & about minor axis(i.e about Y axis) are as follows:
Wz(dead) =39.13kg/m Wz(live) =212.51kg/m Wz(wind) =245.70kg/m Wy(dead) =13.04kg/m Wy(live) =70.84kg/m
Hence factored Minor Axis Moment Due to Dead and Live load (My) = 7864.5 kg-cm
Factored Major Axis moment due to Dead and Wind load = Mzsupport) = 96984 kg-cm
Hence =My/Mdy+Mz/Mdz = 0.81 < 1.0, OK
Deflection of purlin at span due to Wind load & Dead Load δ = 8.21 mm <Lx/200,OK
Hence provideMC125as purlin with 1 no sag rod for span 5m