Signal List

This document provides a signal list for unit 1/2 of the Nkusi 16 hydropower project in the final documentation. It details 60 signals related to mechanics for the turbine including temperature, pressure, levels, positions, and alarms. Each signal includes the unit, equipment, signal name, description, status source, and destination with adjusting values.

Uploaded by

Ddumba
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
242 views

Signal List

This document provides a signal list for unit 1/2 of the Nkusi 16 hydropower project in the final documentation. It details 60 signals related to mechanics for the turbine including temperature, pressure, levels, positions, and alarms. Each signal includes the unit, equipment, signal name, description, status source, and destination with adjusting values.

Uploaded by

Ddumba
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 40

Projekt: project: Nkusi 16 installatio signal list U1/2 (KKS)

Bestell-Nr.: order no.: M-1315843-E n Final Documentation


Turbine 2 x Francis altitude Heinz Haberbosch
Einstellwert
KKS Beschreibung Zustand Quelle Ziel
e
Unit Function Equip- ment Signal Description Status source destination adjusting

Signal List Mechanics


60 LNA10 CF001 XJ01 flow deemed energy (head water +60LNA10 +60LPB10
level) CF001
60 LPA10 CL001 XJ01 head water level upstream fine trash +60LNA10 +60LPB10
rack CL001
60 LPC10 CL001 XJ01 head water level downstream fine +60LNA10 +60LPB10
trash rack CL002
60 LNA10 CL001 XJ01 head water level reservoir +60LNA10 +60LPB10
CL003
60 CGA10 CE101 ZM01 common signal MCB monitoring at +60CGA10 +60CGA10
INTAKE - no alarm
60 MEY50 EH101 XM01 railswitch at INTAKE - no fault +60CGA10 +60CGA10

1/2 MEA10 CT001 XR01 Temperature turbine sealing box +1/2MEA10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEA20 CG001 XJ01 position wicket gate +1/2MEA10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB60 CP001 XJ01 pressure in front of Main Inlet Valve +1/2MEB60 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MEB60 CP002 XJ01 pressure behind Main Inlet Valve +1/2MEB60 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MEB60 CG101 XG01 Main Inlet Valve is open +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB60 CG102 XG02 Main Inlet Valve is closed +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB60 CG103 XG03 Main Inlet Valve > 90% open +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB60 CG104 XG01 MIV is locked in open position +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB60 CG105 XG02 MIV is locked in closed position +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB50 CG101 XG01 bypass valve is open +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEB50 CG102 XG02 bypass valve is closed +1/2MEB60 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 AP001 -M01 lubrication oil pump +1/2CHA10 +1/2MEV10 see KKS-list
GS100 mechanics
1/2 MEV10 AP001 YB01 lubrication oil pump ON +1/2CHA10 +1/2CHA10 see KKS-list
mechanics
1/2 MEV10 AP001 YB02 lubrication oil pump OFF +1/2CHA10 +1/2CHA10 see KKS-list
mechanics
1/2 MEV10 AP001 XM01 MCB lubrication oil pump tripped +1/2CHA10 +1/2CGA10 see KKS-list
mechanics
1/2 MEV10 CL101 XE51 lubrication oil level not too high +1/2MEV10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 CL101 XE02 lubrication oil level not too low +1/2MEV10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 CP101 XM51 lubrication oil filter not clogged +1/2MEV10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 CP102 XE02 lubrication oil pressure not too low +1/2MEV10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 CP102 XE51 lubrication oil pressure not too high +1/2MEV10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 CT001 XR01 lubrication oil temperature +1/2MEV10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEV10 CF101 XM02 oil flow gen. guide bearing DE not low +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MEV10 CF101 XE02 oil flow gen. guide bearing DE not too +1/2MKA10 +1/2CGA10 see KKS-list
low GH020 mechanics
1/2 MEV10 CF102 XM02 oil flow gen. thrust bearing DE not low +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MEV10 CF102 XE02 oil flow gen. thrust bearing DE not too +1/2MKA10 +1/2CGA10 see KKS-list
low GH020 mechanics
1/2 MEV10 CF103 XM02 oil flow gen. counter thrust bearing +1/2MKA10 +1/2CGA10 see KKS-list
DE not low GH020 mechanics
1/2 MEV10 CF103 XE02 oil flow gen. counter thrust bearing +1/2MKA10 +1/2CGA10 see KKS-list
DE not too low GH020 mechanics
1/2 MEV20 CF101 XM02 oil flow gen. guide bearing NDE not +1/2MKA10 +1/2CGA10 see KKS-list
low GH020 mechanics
1/2 MEV20 CF101 XE02 oil flow gen. guide bearing NDE not +1/2MKA10 +1/2CGA10 see KKS-list
too low GH020 mechanics
1/2 MEX10 AP001 -M01 governor oil pump 1 +1/2CHA10 +1/2MEX10 see KKS-list
GS100 mechanics
1/2 MEX10 AP001 YB01 governor oil pump 1 ON +1/2CGA10 +1/2CHA10 see KKS-list
mechanics
1/2 MEX10 AP001 XM01 MCB governor oil pump 1 is tripped +1/2CHA10 +1/2CGA10 see KKS-list
mechanics
1/2 MEX12 AP001 -M01 governor oil pump 2 +1/2CHA10 +1/2MEX12 see KKS-list
GS100 mechanics
1/2 MEX12 AP001 YB01 governor oil pump 2 ON +1/2CGA10 +1/2CHA10 see KKS-list
mechanics
1/2 MEX12 AP001 XM01 MCB governor oil pump 2 is tripped +1/2CHA10 +1/2CGA10 see KKS-list
mechanics
1/2 MEX10 CL101 XE51 governor oil level not too high +1/2MEX10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEX10 CL101 XE02 governor oil level not too low +1/2MEX10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEX10 CL101 XM02 governor oil level not low +1/2MEX10 +1/2CGA10 see KKS-list
GH010 mechanics
too high, +1/2MEX10 see KKS-list
1/2 MEX10 CP001 XJ01 governor oil pressure +1/2CGA10
pump off GH010 mechanics
1/2 MEX10 CP103 XD02 governor oil pressure not too low pump on, +1/2MEX10 +1/2CGA10 see KKS-list
too low GH010 mechanics
1/2 MEX10 CP104 XD02 nitrogen pressure not too low +1/2MEX10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEX10 CP101 XM51 governor oil filter not clogged +1/2MEX10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEX10 CT001 XR01 temperature governor oil +1/2MEX10 +1/2CGA10 see KKS-list
GH010 mechanics
1/2 MEX20 AA001 YJ01 control signal wicket gate servo valve +1/2CGA10 +1/2MEX10 see KKS-list
GH010 mechanics
1/2 MEX34 AA101 YB01 brake ON (ENERGIZE solenoid +1/2CGA10 +1/2MEX10 see KKS-list
valve) GH010 mechanics
1/2 MEX34 AA101 YB02 brake OFF (ENERGIZE solenoid +1/2CGA10 +1/2MEX10 see KKS-list
valve) GH010 mechanics
1/2 MEX60 AA101 YB01 Main Inlet Valve OPEN +1/2CGA10 +1/2MEX10 see KKS-list
GH010 mechanics
1/2 MEX50 AA101 YB01 Bypass of main inlet valve OPEN +1/2CGA10 +1/2MEX10 see KKS-list
GH010 mechanics
1/2 MEX70 AA101 YD01 emergency shut down W G +1/2CGA10 +1/2MEX10 see KKS-list
GH010 mechanics
1/2 MEX70 AA102 YD01 emergency shut down MIV +1/2CGA10 +1/2MEX10 see KKS-list
GH010 mechanics
1/2 MEX70 CE101 XD01 emergency shutdown (mech.) relay +1/2CGA10 +1/2CGA10 see KKS-list
energized mechanics
1/2 MEX70 CE101 XE03 quick shutdown (electr.) relay +1/2CGA10 +1/2CGA10 see KKS-list
energized mechanics
1/2 MEX70 AA101 YD01 no emergency shut down mechanical +1/2CGA10 +1/2CGA10 see KKS-list
(AA101/AA102) mechanics
1/2 MEX70 AA101 YE01 no quick shut down - electrical +1/2CGA10 +1/2CGA10 see KKS-list
mechanics
1/2 MKA10 AC001 -E01 generator standstill heater +1/2CHA10 +1/2MKA10 see KKS-list
GH020 mechanics
1/2 MKA10 AC001 YB01 generator standstill heater ON +1/2CGA10 +1/2CHA10 see KKS-list
mechanics
1/2 MKA10 CL101 XE51 generator heat exchanger - no +1/2MKA10 +1/2CGA10 see KKS-list
leakage GH020 mechanics
1/2 MKA10 CT001 XR01 temperature generator winding U +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA10 CT002 XR01 temperature generator winding V +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA10 CT003 XR01 temperature generator winding W +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA10 CT010 XR01 Temperature generator cold air IN +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA10 CT012 XR01 Temperature generator hot air Out +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA34 CG101 XG01 brake 1 is applied +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA34 CG102 XG01 brake 1 is released +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA34 CG103 XM51 brake 1 is not worn out +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA34 CG111 XG01 brake 2 is applied +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA34 CG112 XG01 brake 2 is released +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA34 CG113 XM51 brake 2 is not worn out +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKA35 CS001 XQ01 speed 1 +1/2MKA10 +1/2CGA10 7 teeth, 750
GH020 1/min
1/2 MKA35 FS002 XJ01 speed 2 (speed analyzer) +1/2CGA10 +1/2CGA10 see KKS-list
mechanics
1/2 MKA35 FS002 XD01 speed analyzer (speed 2): no +1/2CGA10 +1/2CGA10 see KKS-list
overspeed mechanics
1/2 MKD10 CT001 XR01 temperature generator thrust bearing +1/2MKA10 +1/2CGA10 see KKS-list
DE GH020 mechanics
1/2 MKD10 CT002 XR01 temperature generator radial bearing +1/2MKA10 +1/2CGA10 see KKS-list
DE GH020 mechanics
1/2 MKD10 CT003 XR01 temperature generator counter thrust +1/2MKA10 +1/2CGA10 see KKS-list
bearing DE GH020 mechanics
1/2 MKD10 CT004 XR01 temperature generator bearing oil +1/2MKA10 +1/2CGA10 see KKS-list
sump DE GH020 mechanics
1/2 MKD20 CT001 XR01 temperature generator bearing NDE +1/2MKA10 +1/2CGA10 see KKS-list
GH020 mechanics
1/2 MKD20 CT002 XR01 temperature generator bearing oil +1/2MKA10 +1/2CGA10 see KKS-list
sump NDE GH020 mechanics
1/2 MKD10 CY010 XM51 vibration generator bearing DE radial +1/2MKA10 +1/2CGA10 see KKS-list
not high GH020 mechanics
1/2 MKD10 CY010 XE51 vibration generator bearing DE radial +1/2MKA10 +1/2CGA10 see KKS-list
not too high GH020 mechanics
1/2 MKD10 CY020 XM51 vibration generator bearing DE axial +1/2MKA10 +1/2CGA10 see KKS-list
not high GH020 mechanics
1/2 MKD10 CY020 XE51 vibration generator bearing DE axial +1/2MKA10 +1/2CGA10 see KKS-list
not too high GH020 mechanics
1/2 MKD20 CY010 XM51 vibration generator bearing NDE +1/2MKA10 +1/2CGA10 see KKS-list
radial not high GH020 mechanics
1/2 MKD20 CY010 XE51 vibration generator bearing NDE +1/2MKA10 +1/2CGA10 see KKS-list
radial not too high GH020 mechanics
1/2 PAB10 AP001 -M01 cooling water pump 1 +1/2CHA10 +1/2PAB10 see KKS-list
GH??? mechanics
1/2 PAB12 AP001 -M01 cooling water pump 2 +1/2CHA10 +1/2PAB10 see KKS-list
GH??? mechanics
1/2 PAB10 AP001 YB01 cooling water pump 1 ON +1/2CGA10 +1/2CHA10 see KKS-list
mechanics
1/2 PAB10 AP001 XM01 MCB cooling water pump 1 is tripped +1/2CHA10 +1/2CGA10 see KKS-list
mechanics
1/2 PAB12 AP001 YB01 cooling water pump 2 ON +1/2CGA10 +1/2CHA10 see KKS-list
mechanics
1/2 PAB12 AP001 XM01 MCB cooling water pump 2 is tripped +1/2CHA10 +1/2CGA10 see KKS-list
mechanics
KKS

Beschreibung Zustand Lieferant Hersteller Gerätetyp Spannung Ausgang Me

Unit Function Equip- ment

ltage supply

signal range measuring range phys. magnitude source destination adjusting record / adjusted Rema

1/2 PAB10 CP001 XJ01 cooling water pressure Andritz Hydro see KKS-list mechanics

1/2 PAB10 CT002 XR01 temperature cooling water forerun generator Andritz Hydro see KKS-list mechanics

1/2 PAB10 CT003 XR01 temperature cooling water return generator Andritz Hydro see KKS-list mechanics

1/2 PAB10 CT004 XR01 temperature cooling water forerun lubrication oil Andritz Hydro see KKS-list mechanics

1 0GMA10 CL101 XM51 flooding switch powerhouse: level not high Andritz Hydro see KKS-list mechanics

24V DC 4 - 20 mA see KKS-list mechanics

PT100 100 - 168 Ohm see KKS-list mechanics

PT100 100 - 168 Ohm see KKS-list mechanics

PT100 100 - 168 Ohm see KKS-list mechanics

24V DC see KKS-list mechanics

+1/2PAB10

GH010

+1/2PAB10

GH010

+1/2PAB10

GH010

+1/2PAB10

GH010

+2MEA10

GH010

+1/2CGA10 see KKS-list mechanics see KKS-list mechanics


+1/2CGA10 see KKS-list mechanics see KKS-list mechanics

+1/2CGA10 see KKS-list mechanics see KKS-list mechanics

+1/2CGA10 see KKS-list mechanics see KKS-list mechanics

+1CGA10 see KKS-list mechanics see KKS-list mechanics

Meiner Meinung nach nur W arnung: Mit

Michael abklären.

21.12.17: Lt. Michael "forerun" anstatt

"return".

only unit 1, coupling relay: one contact to terminals

x <

<<

x > >> x > >> x > >>

1 0MEB10 CF001 XJ01 flow penstock (client) Client see KKS-list mechanics

2-wire current loop 24V DC 4 - 20 mA see KKS-list mechanics

see KKS-list mechanics +client +1CGA10 see KKS-list mechanics see KKS-list mechanics

only unit 1, overv. protect. in +1CGA10,

cable delivered by client x

Internal - Control elements and indications

1/2 CGA10 GS101 XG01 start sequence ON (pushbutton) Andritz Hydro pushbu

1/2 CGA10 GS102 XG02 stop sequence ON (pushbutton) Andritz Hydro pushb

1/2 CGA10 GS103 XG01 control location REMOTE (switch) Andritz Hydro switch,

1/2 CGA10 GS103 XG02 operating mode AUTOMATIC (switch) Andritz Hydro switch,

1/2 CGA10 GS103 XG03 operating mode MANUAL ENABLE (switch) Andritz Hydro switch

1/2 CGA10 GS104 XG01 UNLOCK after shutdown (pushbutton) Andritz Hydro pushb

1/2 CGA10 GS105 XG01 RELEASE synchronisation (pushbutton) Andritz Hydro pushb

1/2 CGA10 GS106 XG02 generator circuit breaker OFF (pushbutton) Andritz Hydro pushb

1/2 CGA10 GS115 YB01 generator circuit breaker is ready (white lamp) Andritz Hydro white

1/2 CGA10 GS120 XG01 ESD Button cubicle: no ESD Andritz Hydro ESD B

24VDC +1/2CGA10 +1/2CGA10

1/2 CGA10 CE101 ZM01 common signal MCB monitoring - no alarm Andritz Hydro fuses /

1/2 CGA10 CE102 ZD01 common signal MCB monitoring - no shut down Andritz Hydro fuses

1/2 CGA10 GS101 YB01 start sequence is running (green lamp) Andritz Hydro green

1/2 CGA10 GS102 YB02 stop sequence is running (red lamp) Andritz Hydro red la

1/2 CGA10 GS111 YB02 shutdown occured - RESET necessary (red lamp) Andritz Hydro red lam

1/2 CGA10 GS112 YB01 common alarm (yellow lamp) Andritz Hydro yellow

1/2 CGA10 GS130 YB01 horn ON Andritz Hydro horn

1/2 CGA10 GS130 XG01 ACKNOW LEDGE horn (pushbutton) Andritz Hydro pushb

1/2 CGA10 GS113 XG01 opening controller OPC ON (switch) Andritz Hydro switch,

1/2 CGA10 GS114 XG01 pushbutton OSP+ Andritz Hydro pushbu

1/2 CGA10 GS114 XG02 pushbutton OSP- Andritz Hydro pushbu

1/2 MEY50 EH100 YQ01 TC watchdog Togglebit Andritz Hydro Pepperl+Fuchs KFD2-S
1/2 MEY50 EH100 XD01 external watchdog TC failure Andritz Hydro Pepperl+Fuchs KFD2

1 0MEY50 EH101 XM01 railswitch - no fault Andritz Hydro

1/2 MEX70 DE101 YB01 UNLOCK QSD/ESD (via TC) Andritz Hydro Phoenix safety

1 0BFA10 EZ101 XM52 auxiliary power supply 400VAC undervoltage Andritz Hydro Phoenix EMDFL

1 0BRV10 GS101 XG01 auxiliary power supply by transformer Andritz Hydro aux-cont

1 0BRV10 GS101 XG02 auxiliary power supply by DIESEL-GEN Andritz Hydro aux-con

Medium Voltage Switchgear

1/2 AJA03 GS100 XG01 generator circuit breaker is on Andritz Hydro

1/2 AJA03 GS100 XG02 generator circuit breaker is off Andritz Hydro

1/2 AJA03 GS100 XG25 generator circuit breaker: spring not charged Andritz Hydro

1/2 AJA03 GS100 XM22 generator circuit breaker in REMOTE mode Andritz Hydro

1/2 AJA03 GS100 XM62 generator circuit breaker vessel: gas pressure low Andritz Hydro

GS100)

1/2 AJA03 GS100 YB02 generator circuit breaker NOT OFF Andritz Hydro

1/2 AJA03 GS180 XG01 unit disconnector in disconnect position Andritz Hydro

1/2 AJA03 GS180 XG02 unit disconnector in closed position Andritz Hydro

1/2 AJA03 GS180 XG03 unit disconnector in earthed position Andritz Hydro

1/2 AJA03 CE101 ZM01 MV-switchgear: MCB not tripped - no warning Andritz Hydro

1/2 AJA03 CE101 ZE01 MV-switchgear: MCB not tripped - no shutdown Andritz Hydro

1 0AJA01 GS100 XG01 out-feeder circuit breaker is on Andritz Hydro

1 0AJA01 GS100 XG02 out-feeder circuit breaker is off Andritz Hydro

1 0AJA01 GS100 XG25 out-feeder circuit breaker: spring not charged Andritz Hydro

1 0AJA01 GS100 XM22 out-feeder circuit breaker in REMOTE mode Andritz Hydro

1 0AJA01 GS100 XM62 out-feeder circuit breaker vessel: gas pressure low Andritz Hydro

1 0AJA01 GS100 YB02 out-feeder circuit breaker OFF Andritz Hydro

Phoenix…HC)

1 0AJA01 GS100 YB01 out-feeder circuit breaker ON (only prepared) Andritz Hydro

Phoenix…HC)

1 0AJA01 GS180 XG01 out-feeder disconnector in disconnect position Andritz Hydro

1 0AJA01 GS180 XG02 out-feeder disconnector in closed position Andritz Hydro

1 0AJA01 GS180 XG03 out-feeder disconnector in earthed position Andritz Hydro

1 0AJA01 CE101 ZM01 out-feeder: MCB tripped - warning Andritz Hydro

1 0AJA04 GS100 XG01 service-feeder circuit breaker is on Andritz Hydro

1 0AJA04 GS100 XG02 service-feeder circuit breaker is off Andritz Hydro

1 0AJA04 CE180 XM01 service-feeder HV fuse not tripped Andritz Hydro

1 0AJA04 GS100 XM62 service-feeder circuit breaker vessel: gas pressure low Andritz Hydro

1 0AJA04 GS100 YB02 service-feeder circuit breaker OFF Andritz Hydro

Phoenix…HC)

1 0AJA04 GS180 XG01 service-feeder disconnector in disconnect position Andritz Hydro

1 0AJA04 GS180 XG02 service-feeder disconnector in closed position Andritz Hydro

1 0AJA04 GS180 XG03 service-feeder disconnector in earthed position Andritz Hydro

1 0AJA04 CE101 ZM01 MV-switchgear: MCB heater tripped - warning Andritz Hydro
1 0AJA01 EZ102 ZM01 out-feeder protection DRS-LIGHT: no malfunction Andritz Hydro

Synchroniser (DEIF)

1/2 MKY10 DE101 XG01 speed set point HIGHER (synchronisation) Andritz Hydro DEIF GPC3

1/2 MKY10 DE101 XG02 speed set point LOW ER (synchronisation) Andritz Hydro DEIF GPC3

1/2 MKY10 DE101 YB01 RELEASE synchronisation Andritz Hydro DEIF GPC3

1/2 MKY10 EZ101 YB01 ACKNOW LEDGE alarm signals Andritz Hydro DEIF GPC

1/2 MKY10 CE001 XJ01 active power (Deif) Andritz Hydro DEIF GPC3

1/2 MKY10 CE002 XJ01 apparent power (Deif) Andritz Hydro DEIF GPC3

1/2 MKY10 EZ101 XM01 generator protection & synchroniser DEIF - no warning Andritz Hydro DEIF GPC3

generator protection & synchroniser DEIF - no trip - resynchronisation

allowed Andritz Hydro DEIF GPC3 24VDC

generator protection & synchroniser DEIF - no shut down -

resynchronisation blocked Andritz Hydro DEIF GPC3 24VDC

1/2 MKY10 EZ101 XD04 generator protection & synchroniser DEIF - no malfunction Andritz Hydro DEIF GPC

Measuring Transducer SINEAX

1 0MKY20 CE001 XJ01 active power (SINEAX) Andritz Hydro SIRAX SINEAX

1 0MKY20 CE002 XJ01 apparent power (SINEAX) Andritz Hydro SIRAX SINEAX

Electrical Protection (DRS Compact)

1/2 CHA10 EZ101 XM01 generator protection tripped (DRS) - resynchronisation allowed Andritz Hydro Andritz Hydro DRS

1/2 CHA10 EZ101 XD02 generator protection tripped (DRS) - resynchronisation blocked Andritz Hydro Andritz Hydro DRS

1/2 CHA10 EZ102 XD01 generator protection (DRS) - no malfunction Andritz Hydro Andritz Hydro DRS

Generator

+1/2MKA10

GH020

+1/2CGA10 0

Excitation THYNE

1/2 MKC10 CE101 XG01 excitation is on Andritz Hydro THYNE

1/2 MKC10 CE101 ZE01 excitation system: no MCB trip (excitation transformer) Andritz Hydro THYN

1/2 MKC10 CE102 XG01 power factor control is on Andritz Hydro THYNE

1/2 MKC10 CE102 XG02 voltage control is on Andritz Hydro THYN

KKS Beschreibung Zustand Quelle Ziel Einstellwert


e
Unit Function Equip- ment Signal Description Status source destination adjusting

1/2 MKC10 CE102 XG03 field current control is on +1/2CHA10 +1/2CGA10

1/2 MKC10 CE102 XG04 var control is on +1/2CHA10 +1/2CGA10

1/2 MKC10 DE101 YB02 excitation OFF +1/2CGA10 +1/2CHA10

1/2 MKC10 DE101 YB01 excitation ON (pulse) +1/2CGA10 +1/2CHA10

1/2 MKC10 DE102 YB01 power factor control ON +1/2CGA10 +1/2CHA10

1/2 MKC10 DE103 YB01 voltage set point HIGHER +1/2CGA10 +1/2CHA10

1/2 MKC10 DE103 YB02 voltage set point LOW ER +1/2CGA10 +1/2CHA10

1/2 MKC10 DE102 YB04 VAR control ON +1/2CGA10 +1/2CHA10

1/2 MKC10 DE102 YB02 voltage control ON +1/2CGA10 +1/2CHA10

1/2 MKC10 DE102 YB03 field current control ON +1/2CGA10 +1/2CHA10


1/2 MKC10 DE102 YB05 grid operation +1/2CGA10 +1/2CHA10

1/2 MKC10 DE105 YB01 Isolated operation ON +1/2CGA10 +1/2CHA10

1/2 MKC10 EZ102 XE01 no malfunction THYNE 1 generator +1/2CHA10 +1/2CGA10


controller
1/2 MKC10 EZ101 XM01 AVR (THYNE 1) excitation warning +1/2CHA10 +1/2CGA10

1/2 MKC10 EZ101 XE01 AVR (THYNE 1) no excitation tripping +1/2CHA10 +1/2CGA10

1/2 MKC10 EZ101 XE02 AVR (THYNE 1) THYNE channel +1/2CHA10 +1/2CGA10
error
1/2 MKC10 CT001 XR01 excitation transformer temperature high +1/2MKA10 +1/2CGA10 >85°C,
too high GH020 >>90°C
Unit Transformer

1/2 BBT10 EZ101 XM51 unit transformer temperature +1/2BBT10 +1/2CGA10


supervision no warning
1/2 BBT10 EZ101 XD51 unit transformer temperature +1/2BBT10 +1/2CGA10
supervision no trip
1/2 BBT10 EZ103 XM51 unit transformer Buchholz supervision +1/2BBT10 +1/2CGA10
- no alarm
1/2 BBT10 EZ103 XD51 unit transformer Buchholz supervision +1/2BBT10 +1/2CGA10
- no trip
1/2 BBT10 EZ105 XD51 unit transformer pressure relief - no +1/2BBT10 +1/2CGA10
trip
1/2 BBT10 EZ110 XD51 unit tranformer remote control system +1/2BBT10 +1/2CGA10
/ tap changer - no trip
1/2 BBT10 CL101 XD51 unit transformer oil level too high +1/2BBT10 +1/2CGA10

1/2 BBT10 CL101 XD02 unit transformer oil level too low +1/2BBT10 +1/2CGA10

1/2 BBT10 CT002 XJ01 unit transformer temperature HV high +1/2BBT10 +1/2CGA10 >100°C,
winding too high >>105°C
1/2 BBT10 CT003 XJ01 unit transformer temperature LV high +1/2BBT10 +1/2CGA10 >100°C,
winding too high >>105°C
1/2 BBT10 CT001 XJ01 unit transformer oil temperature high +1/2BBT10 +1/2CGA10 >95°C,
too high >>100°C
Meters on cubicles

1/2 MEA20 FG001 YJ01 indication wicket gate +1/2CGA10 +1/2CGA10

1/2 MKA35 FS001 YJ01 indication speed +1/2CGA10 +1/2CGA10

1/2 LNA10 FL001 YJ01 indication head water level +1/2CGA10 +1/2CGA10

1/2 MEB60 FP001 YJ01 indication penstock pressure +1/2CGA10 +1/2CGA10

24VDC System

1 0BTA10 CE101 ZE01 UPS: battery capacity too low +0BTA10 +1CGA10 time delay

1 0BTA10 CE102 ZM51 UPS: operation not via battery +0BTA10 +1CGA10

1 0BTA10 CE103 ZM01 UPS: no fuse trip +0BTA10 +1CGA10

1 0BTA10 CE104 ZM01 UPS: spare +0BTA10 +1CGA10

Blackstart and Isolated Operation

1/2 MKY10 DE200 YB01 ENABLE black-softstart +1/2CGA10 +1/2CHA10

1/2 MKY10 DE200 YB02 ENABLE black closing of GCB +1/2CGA10 +DEIF

1/2 MKY10 DE200 YB03 isolated operation is active +1/2CGA10 +1/2CGA10

1/2 MKY10 DE200 YB04 blackstart / isolated operation is +1/2CGA10 +1/2CGA10


active (yellow lamp)
1/2 MKA35 FS001 XQ01 speed 3 (SI1010) SI1010 +1/2CGA10

Auxiliary Transformer

1 0BAT10 EZ101 XM01 aux. transformer Hermetic Protection +0BAT10 +1CGA10 >85°C
temperature - no warning
1 0BAT10 EZ101 XE01 aux. transformer Hermetic Protection +0BAT10 +1CGA10 >>95°C
temperature - no trip
1 0BAT10 EZ103 XM51 aux. transformer Hermetic Protection +0BAT10 +1CGA10 0,325 bar
Gas - no trip
1 0BAT10 EZ105 XM51 aux. transformer Hermetic Portection +0BAT10 +1CGA10
Pressure - no trip
1 0BAT10 CT001 XJ01 aux. transformer temperature high +0BAT10 +1CGA10 >90°C;
too high >>100°C
Intake Transformer 15kVA
1 0BAT12 CT001 XR01 intake transformer (power house) high +0BAT12 +1CGA01 >110°C,
temperature winding U too high >>120°C
1 0BAT12 CT002 XR01 intake transformer (power house) high +0BAT12 +1CGA01 >110°C,
temperature winding V too high >>120°C
1 0BAT12 CT002 XR01 intake transformer (power house) high +0BAT12 +1CGA01 >110°C,
temperature winding W too high >>120°C
60 BAT12 CT001 XR01 intake transformer (intake) high +60BAT12 +60LPB10
temperature winding U too high
60 BAT12 CT002 XR01 intake transformer (intake) high +60BAT12 +60LPB10
temperature winding V too high
60 BAT12 CT002 XR01 intake transformer (intake) high +60BAT12 +60LPB10
temperature winding W too high
24VDC System Intake

60 BTA10 CE101 ZE01 UPS Intake: battery capacity too low +0BTA10 +1CGA10

60 BTA10 CE102 ZM51 UPS Intake: operation not via battery +0BTA10 +1CGA10

60 BTA10 CE103 ZM01 UPS Intake: no fuse trip +0BTA10 +1CGA10

Diesel Generator Set

1 0BRV10 CE101 XM01 DGset: no fuel reserve +0BRV10 +1CGA10

1 0BRV10 CE101 XM02 DGset: no common warning / no +0BRV10 +1CGA10


shutdown BOC
1 0BRV10 CE101 XM03 DGset: not in Automatic Mode +0BRV10 +1CGA10

1 0BRV10 CE101 XM04 DGset: no Alarm Maintenance +0BRV10 +1CGA10

1 CE101 XG05 message 5 +0BRV10 +1CGA10

Client others

60 LPC10 CF001 XJ01 environmental flow +client +60LPB10

0BRV10

Unit Function Equipment SC Designation Measuring source


Range
1/2 MKA35 CS001 XQ0 speed 1 see KKS-list mechanics +1/2MKA10 GH020
1

#NV #NV #NV #NV spare #NV #NV

1/2 MKA35 FS001 XQ0 speed 3 (SI1010) 0 SI1010


1

#NV #NV #NV #NV spare #NV #NV

1/2 MEA20 CG001 XJ0 position wicket gate see KKS-list mechanics +1/2MEA10 GH010
1

1/2 MKY10 CE002 XJ0 apparent power (Deif) -0.3..6.7 MVA +1/2CHA10
1

1/2 MKA35 FS002 XJ0 speed 2 (speed analyzer) see KKS-list mechanics +1/2CGA10
1
1/2 MKY10 CE001 XJ0 active power (Deif) -0.3..6.7 MW +1/2CHA10
1

1/2 MEB60 CP001 XJ0 pressure in front of Main Inlet Valve see KKS-list mechanics +1/2MEB60 GH020
1

1/2 MEB60 CP002 XJ0 pressure behind Main Inlet Valve see KKS-list mechanics +1/2MEB60 GH020
1

#NV #NV #NV #NV spare #NV #NV

1/2 MEX10 CP001 XJ0 governor oil pressure see KKS-list mechanics +1/2MEX10 GH010
1

1/2 PAB10 CP001 XJ0 cooling water pressure see KKS-list mechanics +1/2PAB10 GH010
1

1 0MEB10 CF001 XJ0 flow penstock (client) see KKS-list mechanics +client
1

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

1/2 CGA10 GS101 XG0 start sequence ON (pushbutton) 0 +1/2CGA10


1
1/2 CGA10 GS102 XG0 stop sequence ON (pushbutton) 0 +1/2CGA10
2
1/2 CGA10 GS103 XG0 control location REMOTE (switch) 0 +1/2CGA10
1
1/2 CGA10 GS103 XG0 operating mode AUTOMATIC (switch) 0 +1/2CGA10
2
1/2 CGA10 GS103 XG0 operating mode MANUAL ENABLE 0 +1/2CGA10
3 (switch)
1/2 CGA10 GS104 XG0 UNLOCK after shutdown (pushbutton) 0 +1/2CGA10
1
1/2 CGA10 GS105 XG0 RELEASE synchronisation 0 +1/2CGA10
1 (pushbutton)
1/2 CGA10 GS106 XG0 generator circuit breaker OFF 0 +1/2CGA10
2 (pushbutton)
1/2 CGA10 CE101 ZM0 common signal MCB monitoring - no 0 +1/2CGA10
1 alarm
1/2 CGA10 CE102 ZD0 common signal MCB monitoring - no 0 +1/2CGA10
1 shut down
1/2 CGA10 GS113 XG0 opening controller OPC ON (switch) 0 +1/2CGA10
1
1/2 CGA10 GS114 XG0 pushbutton OSP+ 0 +1/2CGA10
1
1/2 CGA10 GS114 XG0 pushbutton OSP- 0 +1/2CGA10
2
1 0BFA10 EZ101 XM5 auxiliary power supply 400VAC 0 +1CHA10
2 undervoltage
1/2 MEY50 EH100 XD0 external watchdog TC failure 0 +1/2CGA10
1
1/2 MKA35 FS002 XD0 speed analyzer (speed 2): no see KKS-list mechanics +1/2CGA10
1 overspeed
1/2 MEX70 CE101 XD0 emergency shutdown (mech.) relay see KKS-list mechanics +1/2CGA10
1 energized
1/2 MEX70 CE101 XE0 quick shutdown (electr.) relay see KKS-list mechanics +1/2CGA10
3 energized
1/2 MEX10 CL101 XE0 governor oil level not too low see KKS-list mechanics +1/2MEX10 GH010
2
1/2 MEX10 CL101 XE5 governor oil level not too high see KKS-list mechanics +1/2MEX10 GH010
1
1/2 MEX10 CP101 XM5 governor oil filter not clogged see KKS-list mechanics +1/2MEX10 GH010
1
1/2 MEX10 CP104 XD0 nitrogen pressure not too low see KKS-list mechanics +1/2MEX10 GH010
2
1/2 MEX10 AP001 XM0 MCB governor oil pump 1 is tripped see KKS-list mechanics +1/2CHA10
1
1/2 MEV10 AP001 XM0 MCB lubrication oil pump tripped see KKS-list mechanics +1/2CHA10
1
1/2 MEX10 CP103 XD0 governor oil pressure not too low see KKS-list mechanics +1/2MEX10 GH010
2
1/2 MEX10 CL101 XM0 governor oil level not low see KKS-list mechanics +1/2MEX10 GH010
2
1/2 MEX12 AP001 XM0 MCB governor oil pump 2 is tripped see KKS-list mechanics +1/2CHA10
1
1/2 MKC10 CE101 ZE0 excitation system: no MCB trip 0 +1/2CHA10
1 (excitation transformer)
1/2 MKC10 CE102 XG0 power factor control is on 0 +1/2CHA10
1
1/2 MKC10 CE102 XG0 voltage control is on 0 +1/2CHA10
2
1/2 MKC10 CE102 XG0 field current control is on 0 +1/2CHA10
3
1/2 MKC10 CE102 XG0 var control is on 0 +1/2CHA10
4
1/2 AJA03 GS100 XG0 generator circuit breaker is off 0 +1/2AJA03
2
1/2 AJA03 GS100 XG0 generator circuit breaker is on 0 +1/2AJA03
1
1/2 AJA03 GS100 XG2 generator circuit breaker: spring not 0 +1/2AJA03
5 charged
1/2 AJA03 GS100 XM2 generator circuit breaker in REMOTE 0 +1/2AJA03
2 mode
1/2 MKA10 CE101 ZD0 common signal no fuse trip generator - 0 +1/2MKA10 GH020
1 shut down
#NV #NV #NV #NV spare (terminals) #NV #NV

1/2 MKC10 CE101 XG0 excitation is on 0 +1/2CHA10


1
1/2 MKY10 DE101 XG0 speed set point HIGHER 0 +1/2CHA10
1 (synchronisation)
1/2 MKY10 DE101 XG0 speed set point LOWER 0 +1/2CHA10
2 (synchronisation)
1/2 MEB50 CG101 XG0 bypass valve is open see KKS-list mechanics +1/2MEB60 GH010
1
1/2 MEB50 CG102 XG0 bypass valve is closed see KKS-list mechanics +1/2MEB60 GH010
2
1/2 MEB60 CG102 XG0 Main Inlet Valve is closed see KKS-list mechanics +1/2MEB60 GH010
2
1/2 MEB60 CG103 XG0 Main Inlet Valve > 90% open see KKS-list mechanics +1/2MEB60 GH010
3
1/2 MEB60 CG101 XG0 Main Inlet Valve is open see KKS-list mechanics +1/2MEB60 GH010
1
1/2 MEB60 CG104 XG0 MIV is locked in open position see KKS-list mechanics +1/2MEB60 GH010
1
1/2 MEB60 CG105 XG0 MIV is locked in closed position see KKS-list mechanics +1/2MEB60 GH010
2
1/2 MKY10 EZ101 XM0 generator protection & synchroniser 0 +1/2CHA10
1 DEIF - no warning
1/2 MKY10 EZ101 XM0 generator protection & synchroniser 0 +1/2CHA10
2 DEIF - no trip - resynchronisation
1/2 MKY10 EZ101 XD0 allowed protection & synchroniser
generator 0 +1/2CHA10
3 DEIF - no shut down -
1/2 MKY10 EZ101 XD0 resynchronisation
generator protectionblocked
& synchroniser 0 +1/2CHA10
4 DEIF - no malfunction
1/2 CGA10 GS120 XG0 ESD Button cubicle: no ESD 0 +1/2CGA10
1
1/2 MKA34 CG101 XG0 brake 1 is applied see KKS-list mechanics +1/2MKA10 GH020
1
1/2 MKA34 CG102 XG0 brake 1 is released see KKS-list mechanics +1/2MKA10 GH020
1
1/2 MKA10 CL101 XE5 generator heat exchanger - no leakage see KKS-list mechanics +1/2MKA10 GH020
1
1/2 MKA34 CG103 XM5 brake 1 is not worn out see KKS-list mechanics +1/2MKA10 GH020
1
1/2 BBT10 EZ101 XM5 unit transformer temperature 0 +1/2BBT10
1 supervision no warning
1/2 BBT10 EZ101 XD5 unit transformer temperature 0 +1/2BBT10
1 supervision no trip
#NV #NV #NV #NV spare (terminals) #NV #NV

1/2 MKC10 EZ102 XE0 no malfunction THYNE 1 generator 0 +1/2CHA10


1 controller
1/2 MKC10 EZ101 XM0 AVR (THYNE 1) excitation warning 0 +1/2CHA10
1
1/2 MKC10 EZ101 XE0 AVR (THYNE 1) no excitation tripping 0 +1/2CHA10
1
1/2 MKC10 EZ101 XE0 AVR (THYNE 1) THYNE channel error 0 +1/2CHA10
2

Unit Function Equipment SC Designation Measuring source


Range
1/2 MKA10 CT001 XR0 temperature generator winding U see KKS-list mechanics +1/2MKA10 GH020
1

1/2 MKA10 CT002 XR0 temperature generator winding V see KKS-list mechanics +1/2MKA10 GH020
1

1/2 MKA10 CT003 XR0 temperature generator winding W see KKS-list mechanics +1/2MKA10 GH020
1

1/2 MKA10 CT012 XR0 Temperature generator hot air OUT see KKS-list mechanics +1/2MKA10 GH020
1

1/2 MKA10 CT010 XR0 Temperature generator cold air IN see KKS-list mechanics +1/2MKA10 GH020
1

1/2 MKD10 CT001 XR0 temperature generator thrust bearing see KKS-list mechanics +1/2MKA10 GH020
1 DE
1/2 MKD10 CT002 XR0 temperature generator radial bearing see KKS-list mechanics +1/2MKA10 GH020
1 DE

1/2 MKD10 CT003 XR0 temperature generator counter thrust see KKS-list mechanics +1/2MKA10 GH020
1 bearing DE

1/2 MKD20 CT001 XR0 temperature generator bearing NDE see KKS-list mechanics +1/2MKA10 GH020
1

1/2 MKD20 CT002 XR0 temperature generator bearing oil see KKS-list mechanics +1/2MKA10 GH020
1 sump NDE

1/2 MEX10 CT001 XR0 temperature governor oil see KKS-list mechanics +1/2MEX10 GH010
1

1/2 MEA10 CT001 XR0 Temperature turbine sealing box see KKS-list mechanics +1/2MEA10 GH010
1

1/2 PAB10 CT002 XR0 temperature cooling water forerun see KKS-list mechanics +1/2PAB10 GH010
1 generator

1/2 PAB10 CT003 XR0 temperature cooling water return see KKS-list mechanics +1/2PAB10 GH010
1 generator

1/2 PAB10 CT004 XR0 temperature cooling water forerun see KKS-list mechanics +1/2PAB10 GH010
1 lubrication oil

#NV #NV #NV #NV spare (terminals) #NV #NV


1/2 MEV10 CL101 XE5 lubrication oil level not too high see KKS-list mechanics +1/2MEV10 GH010
1
1/2 MEV10 CL101 XE0 lubrication oil level not too low see KKS-list mechanics +1/2MEV10 GH010
2
1/2 MEV10 CP101 XM5 lubrication oil filter not clogged see KKS-list mechanics +1/2MEV10 GH010
1
1/2 MEV10 CP102 XE0 lubrication oil pressure not too low see KKS-list mechanics +1/2MEV10 GH010
2
1/2 MEV10 CP102 XE5 lubrication oil pressure not too high see KKS-list mechanics +1/2MEV10 GH010
1
1/2 MEV10 CF101 XM0 oil flow gen. guide bearing DE not low see KKS-list mechanics +1/2MKA10 GH020
2
1/2 MEV10 CF101 XE0 oil flow gen. guide bearing DE not too see KKS-list mechanics +1/2MKA10 GH020
2 low
1/2 PAB10 AP001 XM0 MCB cooling water pump 1 is tripped see KKS-list mechanics +1/2CHA10
1
1/2 PAB12 AP001 XM0 MCB cooling water pump 2 is tripped see KKS-list mechanics +1/2CHA10
1
#NV #NV #NV #NV spare (relay,terminals) #NV #NV

1/2 CHA10 EZ101 XM0 generator protection tripped (DRS) - 0 +1CHA01


1 resynchronisation allowed
1/2 CHA10 EZ101 XD0 generator protection tripped (DRS) - 0 +1CHA01
2 resynchronisation blocked
1/2 CHA10 EZ102 XD0 generator protection (DRS) - no 0 +1CHA01
1 malfunction
1/2 BBT10 EZ103 XM5 unit transformer Buchholz supervision - 0 +1/2BBT10
1 no alarm
1/2 BBT10 EZ103 XD5 unit transformer Buchholz supervision - 0 +1/2BBT10
1 no trip
1/2 BBT10 EZ105 XD5 unit transformer pressure relief - no trip 0 +1/2BBT10
1
1/2 CGA10 GS101 YB0 start sequence is running (green lamp) 0 +1/2CGA10
1
1/2 CGA10 GS102 YB0 stop sequence is running (red lamp) 0 +1/2CGA10
2
1/2 MKC10 DE101 YB0 excitation OFF 0 +1/2CGA10
2
1/2 MKC10 DE101 YB0 excitation ON (pulse) 0 +1/2CGA10
1
1/2 MKC10 DE102 YB0 power factor control ON 0 +1/2CGA10
1
1/2 MKC10 DE103 YB0 voltage set point HIGHER 0 +1/2CGA10
1
1/2 MKC10 DE103 YB0 voltage set point LOWER 0 +1/2CGA10
2
1/2 MKC10 DE102 YB0 VAR control ON 0 +1/2CGA10
4
1/2 MKY10 DE101 YB0 RELEASE synchronisation 0 +1/2CGA10
1
1/2 AJA03 GS100 YB0 generator circuit breaker NOT OFF 0 +1/2CGA10
2
1/2 MKC10 DE102 YB0 voltage control ON 0 +1/2CGA10
2
1/2 MKC10 DE102 YB0 field current control ON 0 +1/2CGA10
3
1/2 MKY10 EZ101 YB0 ACKNOWLEDGE alarm signals 0 +1/2CGA10
1
1/2 MKC10 DE105 YB0 Isolated operation ON 0 +1/2CGA10
1
1/2 MKC10 DE102 YB0 grid operation 0 +1/2CGA10
5
1/2 CGA10 GS112 YB0 common alarm (yellow lamp) 0 +1/2CGA10
1
1/2 MEX10 AP001 YB0 governor oil pump 1 ON see KKS-list mechanics +1/2CGA10
1
1/2 MEV10 AP001 YB0 lubrication oil pump ON see KKS-list mechanics +1/2CHA10
1
1/2 MEX12 AP001 YB0 governor oil pump 2 ON see KKS-list mechanics +1/2CGA10
1
1/2 MEV10 AP001 YB0 lubrication oil pump OFF see KKS-list mechanics +1/2CHA10
2
1/2 CGA10 GS115 YB0 generator circuit breaker is ready 0 +1/2CGA10
1 (white lamp)
1/2 MEX60 AA101 YB0 Main Inlet Valve OPEN see KKS-list mechanics +1/2CGA10
1
1/2 PAB10 AP001 YB0 cooling water pump 1 ON see KKS-list mechanics +1/2CGA10
1
1/2 PAB12 AP001 YB0 cooling water pump 2 ON see KKS-list mechanics +1/2CGA10
1
1/2 MEX70 AA101 YD0 no emergency shut down mechanical see KKS-list mechanics +1/2CGA10
1 (AA101/AA102)
1/2 MEX70 AA101 YE0 no quick shut down - electrical see KKS-list mechanics +1/2CGA10
1
1/2 MEX34 AA101 YB0 brake OFF (ENERGIZE solenoid valve) see KKS-list mechanics +1/2CGA10
2
1/2 MEX50 AA101 YB0 Bypass of main inlet valve OPEN see KKS-list mechanics +1/2CGA10
1
1/2 MEX70 DE101 YB0 UNLOCK QSD/ESD (via TC) 0 +1/2CGA10
1
1 0AJA01 GS100 YB0 out-feeder circuit breaker OFF 0 +1CGA10
2
1/2 CGA10 GS111 YB0 shutdown occured - RESET necessary 0 +1/2CGA10
2 (red lamp)
1/2 MKA10 AC001 YB0 generator standstill heater ON see KKS-list mechanics +1/2CGA10
1
1/2 MEY50 EH100 YQ0 TC watchdog Togglebit 0 +1/2CGA10
1
#NV #NV #NV #NV xx #NV #NV

#NV #NV #NV #NV xx #NV #NV

#NV #NV #NV #NV xx #NV #NV

#NV #NV #NV #NV xx #NV #NV

#NV #NV #NV #NV xx #NV #NV

#NV #NV #NV #NV xx #NV #NV

#NV #NV #NV #NV xx #NV #NV

1 0AJA01 GS100 YB0 out-feeder circuit breaker ON (only 0 +1CGA10


1 prepared)
1/2 MEX34 AA101 YB0 brake ON (ENERGIZE solenoid valve) see KKS-list mechanics +1/2CGA10
1
#NV #NV #NV #NV spare (relay,terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

1/2 MKY10 DE200 YB0 ENABLE black-softstart 0 +1/2CGA10


1
1/2 MKY10 DE200 YB0 ENABLE black closing of GCB 0 +1/2CGA10
2
1/2 MKY10 DE200 YB0 isolated operation is active 0 +1/2CGA10
3
1/2 MKY10 DE200 YB0 blackstart / isolated operation is active 0 +1/2CGA10
4 (yellow lamp)

Unit Function Equipment SC Designation Measuring source


Range
1/2 MEX20 AA001 YJ0 control signal wicket gate servo valve see KKS-list mechanics +1/2CGA10
1

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

1/2 MEA20 FG001 YJ0 indication wicket gate 0..100% +1/2CGA10


1
1/2 MEB60 FP001 YJ0 indication penstock pressure 0..18 bar +1/2CGA10
1

1/2 MKA35 FS001 YJ0 indication speed 0..200% +1/2CGA10


1

1/2 LNA10 FL001 YJ0 indication head water level 782.30 - 788.30 masl +1/2CGA10
1

1/2 MKD10 CT004 XR0 temperature generator bearing oil see KKS-list mechanics +1/2MKA10 GH020
1 sump DE

#NV #NV #NV #NV spare (terminals) #NV #NV

1/2 MKC10 CT001 XR0 excitation transformer temperature -20°C..140°C +1/2MKA10 GH020
1

1/2 MEV10 CT001 XR0 lubrication oil temperature see KKS-list mechanics +1/2MEV10 GH010
1

1/2 BBT10 CT001 XJ0 unit transformer oil temperature 0°C..150°C +1/2BBT10
1

1/2 BBT10 CT002 XJ0 unit transformer temperature HV 0°C..150°C +1/2BBT10


1 winding

1/2 BBT10 CT003 XJ0 unit transformer temperature LV 0°C..150°C +1/2BBT10


1 winding
#NV #NV #NV #NV spare #NV #NV

1/2 CGA10 GS130 YB0 horn ON 0 +1/2CGA10


1
#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

1/2 MKD10 CY010 XM5 vibration generator bearing DE radial see KKS-list mechanics +1/2MKA10 GH020
1 not high
1/2 MKD10 CY010 XE5 vibration generator bearing DE radial see KKS-list mechanics +1/2MKA10 GH020
1 not too high
1/2 MKD10 CY020 XM5 vibration generator bearing DE axial see KKS-list mechanics +1/2MKA10 GH020
1 not high
1/2 MKD10 CY020 XE5 vibration generator bearing DE axial see KKS-list mechanics +1/2MKA10 GH020
1 not too high
1/2 MKD20 CY010 XM5 vibration generator bearing NDE radial see KKS-list mechanics +1/2MKA10 GH020
1 not high
1/2 MKD20 CY010 XE5 vibration generator bearing NDE radial see KKS-list mechanics +1/2MKA10 GH020
1 not too high
1/2 MEV10 CF102 XM0 oil flow gen. thrust bearing DE not low see KKS-list mechanics +1/2MKA10 GH020
2
1/2 MEV10 CF102 XE0 oil flow gen. thrust bearing DE not too see KKS-list mechanics +1/2MKA10 GH020
2 low
1/2 MEV20 CF101 XM0 oil flow gen. guide bearing NDE not see KKS-list mechanics +1/2MKA10 GH020
2 low
1/2 MEV20 CF101 XE0 oil flow gen. guide bearing NDE not too see KKS-list mechanics +1/2MKA10 GH020
2 low
1/2 AJA03 GS100 XM6 generator circuit breaker vessel: gas 0 +1/2AJA03
2 pressure low
1/2 AJA03 GS180 XG0 unit disconnector in disconnect position 0 +1/2AJA03
1
1/2 AJA03 GS180 XG0 unit disconnector in closed position 0 +1/2AJA03
2
1/2 AJA03 GS180 XG0 unit disconnector in earthed position 0 +1/2AJA03
3
1/2 AJA03 CE101 ZM0 MV-switchgear: MCB not tripped - no 0 +1/2AJA03
1 warning
1/2 AJA03 CE101 ZE0 MV-switchgear: MCB not tripped - no 0 +1/2AJA03
1 shutdown
1/2 MEV10 CF103 XM0 oil flow gen. counter thrust bearing DE see KKS-list mechanics +1/2MKA10 GH020
2 not low
1/2 MEV10 CF103 XE0 oil flow gen. counter thrust bearing DE see KKS-list mechanics +1/2MKA10 GH020
2 not too low
1/2 MKA34 CG111 XG0 brake 2 is applied see KKS-list mechanics +1/2MKA10 GH020
1
1/2 MKA34 CG112 XG0 brake 2 is released see KKS-list mechanics +1/2MKA10 GH020
1
1/2 MKA34 CG113 XM5 brake 2 is not worn out see KKS-list mechanics +1/2MKA10 GH020
1
1/2 BBT10 EZ110 XD5 unit tranformer remote control system / 0 +1/2BBT10
1 tap changer - no trip
1/2 BBT10 CL101 XD5 unit transformer oil level too high 0 +1/2BBT10
1
1/2 BBT10 CL101 XD0 unit transformer oil level too low 0 +1/2BBT10
2
#NV #NV #NV #NV spare (relay,terminals) #NV #NV

1/2 CGA10 GS130 XG0 ACKNOWLEDGE horn (pushbutton) 0 +1/2CGA10


1
#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

#NV #NV #NV #NV spare (relay,terminals) #NV #NV

Unit Function Equipment SC Designation Measuring source


Range
ONLY Unit 1, located in +0BTA10 #NV #NV

1 0MKY20 CE001 XJ0 active power (SINEAX) -0.6..13.4 MW +1CHA10


1

1 0MKY20 CE002 XJ0 apparent power (SINEAX) 0..13.4 MVA +1CHA10


1

1 0BAT10 CT001 XJ0 aux. transformer temperature 0°C..150°C +0BAT10


1

#NV #NV #NV #NV spare (terminals) #NV #NV

1 0BAT12 CT001 XR0 intake transformer (power house) -20°C..140°C +0BAT12


1 temperature winding U

1 0BAT12 CT002 XR0 intake transformer (power house) -20°C..140°C +0BAT12


1 temperature winding V

1 0BAT12 CT002 XR0 intake transformer (power house) -20°C..140°C +0BAT12


1 temperature winding W
#NV #NV #NV #NV spare #NV #NV

1 0BTA10 CE101 ZE0 UPS: battery capacity too low 0 +0BTA10


1
1 0BTA10 CE102 ZM5 UPS: operationnot via battery 0 +0BTA10
1
1 0BTA10 CE103 ZM0 UPS: no fuse trip 0 +0BTA10
1
1 0MEY50 EH101 XM0 railswitch - no fault 0 +1/2CGA10
1
1 0BAT10 EZ101 XM0 aux. transformer Hermetic Protection 0 +0BAT10
1 temperature - no warning
1 0BAT10 EZ101 XE0 aux. transformer Hermetic Protection 0 +0BAT10
1 temperature - no trip
1 0BAT10 EZ103 XM5 aux. transformer Hermetic Protection 0 +0BAT10
1 Gas - no trip
1 0BAT10 EZ105 XM5 aux. transformer Hermetic Portection 0 +0BAT10
1 Pressure - no trip
1 0BRV10 CE101 XM0 DGset: no fuel reserve 0 +0BRV10
1
1 0BRV10 CE101 XM0 DGset: no common warning / no 0 +0BRV10
2 shutdown BOC
1 0BRV10 CE101 XM0 DGset: not in Automatic Mode 0 +0BRV10
3
1 0BRV10 CE101 XM0 DGset: no Alarm Maintenance 0 +0BRV10
4
1 0BRV10 GS101 XG0 auxiliary power supply by transformer 0 +0BRV10GH20
1
1 0BRV10 GS101 XG0 auxiliary power supply by DIESEL- 0 +0BRV10GH20
2 GEN
1 0GMA10 CL101 XM5 flooding switch powerhouse: level not see KKS-list mechanics +2MEA10 GH010
1 high
1 0AJA01 EZ102 ZM0 out-feeder protection DRS-LIGHT: no 0 +0AJA04
1 malfunction
1 0AJA01 GS100 XG0 out-feeder circuit breaker is off 0 +0AJA01
2
1 0AJA01 GS100 XG0 out-feeder circuit breaker is on 0 +0AJA01
1
1 0AJA01 GS100 XG2 out-feeder circuit breaker: spring not 0 +0AJA01
5 charged
1 0AJA01 GS100 XM6 out-feeder circuit breaker vessel: gas 0 +0AJA01
2 pressure low
1 0AJA01 GS180 XG0 out-feeder disconnector in disconnect 0 +0AJA01
1 position
1 0AJA01 GS180 XG0 out-feeder disconnector in closed 0 +0AJA01
2 position
1 0AJA01 GS180 XG0 out-feeder disconnector in earthed 0 +0AJA01
3 position
1 0AJA01 CE101 ZM0 out-feeder: MCB tripped - warning 0 +0AJA01
1
1 0AJA01 GS100 XM2 out-feeder circuit breaker in REMOTE 0 +1/2AJA03
2 mode
#NV #NV #NV #NV spare (terminals) #NV #NV

1 0AJA04 CE180 XM0 service-feeder HV fuse not tripped 0 +0AJA04


1
1 0AJA04 GS100 XM6 service-feeder circuit breaker vessel: 0 +0AJA04
2 gas pressure low
1 0AJA04 GS180 XG0 service-feeder disconnector in 0 +0AJA04
1 disconnect position
1 0AJA04 GS180 XG0 service-feeder disconnector in closed 0 +0AJA04
2 position
1 0AJA04 GS180 XG0 service-feeder disconnector in earthed 0 +0AJA04
3 position
1 0AJA04 CE101 ZM0 MV-switchgear: MCB heater tripped - 0 +0AJA04
1 warning
Unit Function Equipment SC Designation CMIC at INTAKE Signal Measuring source
Range Range
60 CGA10 CE101 ZM0 common signal MCB monitoring at 0 0 +60CGA10
1 INTAKE - no alarm
60 MEY50 EH101 XM0 railswitch at INTAKE - no fault 0 0 +60CGA10
1
60 BTA10 CE101 ZE01 UPS Intake: battery capacity too low 0 0 +0BTA10

60 BTA10 CE102 ZM5 UPS Intake: operation not via 0 0 +0BTA10


1 battery
60 BTA10 CE103 ZM0 UPS Intake: no fuse trip 0 0 +0BTA10
1
#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (terminals) #NV #NV #NV

#NV #NV #NV #NV spare (relay, teminals) #NV #NV #NV

#NV #NV #NV #NV spare (relay, teminals) #NV #NV #NV

60 LNA10 CF001 XJ01 flow deemed energy (head water 4 - 20 mA 0 +60LNA10


level) CF001

60 LPA10 CL001 XJ01 head water level upstream fine 4 - 20 mA 0 +60LNA10


trash rack CL001

60 LPC10 CL001 XJ01 head water level downstream fine 4 - 20 mA 0 +60LNA10


trash rack CL002

60 LNA10 CL001 XJ01 head water level reservoir 4 - 20 mA 0 +60LNA10


CL003

60 BAT12 CT001 XR0 intake transformer (intake) 0 -20°C..140°C +60BAT12


1 temperature winding U

60 BAT12 CT002 XR0 intake transformer (intake) 0 -20°C..140°C +60BAT12


1 temperature winding V

60 BAT12 CT002 XR0 intake transformer (intake) 0 -20°C..140°C +60BAT12


1 temperature winding W
#NV #NV #NV #NV spare #NV #NV #NV

60 LPC10 CF001 XJ01 environmental flow 4 - 20 mA 0 +client

#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare #NV #NV #NV

#NV #NV #NV #NV spare #NV #NV #NV


Protokollw
Bemerkung
erte
record / Remark
adjusted

overv. protect. in
+60LPB10
overv. protect. in
+60LPB10
overv. protect. in
+60LPB10
overv. protect. in
+60LPB10

see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS- coupling relay
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS- W eidmüller
list Optokoppler, MOS
mechanics
see KKS- 24VDC/5-33VDC
W eidmüller 10A
list Optokoppler, MOS
mechanics
see KKS- 24VDC/5-33VDC
W eidmüller 10A
list Optokoppler, MOS
mechanics
see KKS- 24VDC/5-33VDC
W eidmüller 10A
list Optokoppler, MOS
mechanics
see KKS- 24VDC/5-33VDC
hardwired from 10A
list Phoenix relay to ESD-
mechanics
see KKS- valve, no ESD
hardwired fromif valve
list energized,
Phoenix relay to ESD-
mechanics
see KKS- valve, no ESD if valve
list energized,
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS- hardwired also into
list ESD-circuit and brake-
mechanics
see KKS- circuit
list
mechanics
see KKS-
list
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics
see KKS-
list
mechanics

Meßbereich Phys. Größe Quelle Ziel Einstellwerte Protokollwerte Bemerkung

mark other action

s
button 24VDC +1/2CGA10 +1/2CGA10

button 24VDC +1/2CGA10 +1/2CGA10

h, 2 pos. 24VDC +1/2CGA10 +1/2CGA10

h, 3 pos. 24VDC +1/2CGA10 +1/2CGA10

h, 3 pos. 24VDC +1/2CGA10 +1/2CGA10

button 24VDC +1/2CGA10 +1/2CGA10

button 24VDC +1/2CGA10 +1/2CGA10

button 24VDC +1/2CGA10 +1/2CGA10

e lamp 24VDC +1/2CGA10 +1/2CGA10

Button, auxiliary contact

/ MCB in CGA 24VDC +1/2CGA10 +1/2CGA10

es / MCB in CGA 24VDC +1/2CGA10 +1/2CGA10

n lamp 24VDC +1/2CGA10 +1/2CGA10

amp 24VDC +1/2CGA10 +1/2CGA10

amp 24VDC +1/2CGA10 +1/2CGA10

w lamp 24VDC +1/2CGA10 +1/2CGA10

24VDC +1/2CGA10 +1/2CGA10

hbutton 24VDC +1/2CGA10 +1/2CGA10

h, 2 pos. 24VDC +1/2CGA10 +1/2CGA10

button 24VDC +1/2CGA10 +1/2CGA10

button 24VDC +1/2CGA10 +1/2CGA10

-SR2-2.W .SM 24VDC +1/2CGA10 +1/2CGA10


D2-SR2-2.W .SM 24VDC +1/2CGA10 +1/2CGA10

24VDC +1/2CGA10 +1/2CGA10

ty valves 24VDC +1/2CGA10 +1/2CGA10

FL3V400 24VDC +1CHA10 +1CGA10

ntact 24VDC +0BRV10GH20 +1CGA10

ntact 24VDC +0BRV10GH20 +1CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2CGA10 +1/2AJA03

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +0AJA01 +1CGA10

24VDC +0AJA01 +1CGA10

24VDC +0AJA01 +1CGA10

24VDC +1/2AJA03 +1/2CGA10

24VDC +0AJA01 +1CGA10

24VDC +1CGA10 +0AJA01

24VDC +1CGA10 +0AJA01

24VDC +0AJA01 +1CGA10

24VDC +0AJA01 +1CGA10

24VDC +0AJA01 +1CGA10

24VDC +0AJA01 +1CGA10

24VDC +0AJA04 +1CGA10

24VDC +0AJA04 +1CGA10

24VDC +0AJA04 +1CGA10

24VDC +0AJA04 +1CGA10

24VDC +1CGA10 +0AJA04

24VDC +0AJA04 +1CGA10

24VDC +0AJA04 +1CGA10

24VDC +0AJA04 +1CGA10

24VDC +0AJA04 +1CGA10


24VDC +0AJA04 +1CGA10

3 24VDC +1/2CHA10 +1/2CGA10

C3 24VDC +1/2CHA10 +1/2CGA10

C3 24VDC +1/2CGA10 +1/2CHA10

C3 24VDC +1/2CGA10 +1/2CHA10

C3 4 - 20 mA -0.3..6.7 MW +1/2CHA10 +1/2CGA10

C3 4 - 20 mA -0.3..6.7 MVA +1/2CHA10 +1/2CGA10

C3 24VDC +1/2CHA10 +1/2CGA10

C +1/2CHA10 +1/2CGA10

C +1/2CHA10 +1/2CGA10

C3 24VDC +1/2CHA10 +1/2CGA10

AX 4 - 20 mA -0.6..13.4 MW +1CHA10 +1CGA10

AX 4 - 20 mA 0..13.4 MVA +1CHA10 +1CGA10

S C2A 24VDC +1CHA01 +1CGA01

S C2A 24VDC +1CHA01 +1CGA01

S C2A 24VDC +1CHA01 +1CGA01

NE 1 24VDC +1/2CHA10 +1/2CGA10

YNE 1 24VDC +1/2CHA10 +1/2CGA10

NE 1 24VDC +1/2CHA10 +1/2CGA10

NE 1 24VDC +1/2CHA10 +1/2CGA10

Protokollw Bemerkung
erte
record / Remark
adjusted
>85°C,
>>90°C

overvoltage protection

overvoltage protection
contact multiplic.
hardwired toprotection
overvoltage QSD-E
contact multiplic.
hardwired toprotection
overvoltage QSD-E
contact multiplic.
hardwired toprotection
overvoltage QSD-E

overvoltage protection

overvoltage protection

overvoltage protection

overvoltage protection

overvoltage protection

overvoltage protection

only unit 1

only unit 1

only unit 1

only unit 1

>85°C only unit 1

>>95°C only unit 1

0,325 bar only unit 1

only unit 1

>90°C; only unit 1


>>100°C
>110°C, only unit 1
>>120°C
>110°C, only unit 1
>>120°C
>110°C, only unit 1
>>120°C

only unit 1

only unit 1

only unit 1

only unit 1

only unit 1

only unit 1

only unit 1

only unit 1

overv. protect. in
+60LPB10

destination device

+1/2CGA10 Braun
A5S0DD0M1810B
48

#NV #NV

+1/2CGA10 SI1010

#NV #NV

+1/2CGA10 0

+1/2CGA10 GPC3

+1/2CGA10 Braun Relay


D521.14
+1/2CGA10 GPC3

+1/2CGA10 0

+1/2CGA10 0

#NV #NV

+1/2CGA10 0

+1/2CGA10 0

+1CGA10 2-wire current loop

#NV #NV

#NV #NV

+1/2CGA10 pushbutton

+1/2CGA10 pushbutton

+1/2CGA10 switch, 2 pos.


+1/2CGA10 switch, 3 pos.

+1/2CGA10 switch, 3 pos.

+1/2CGA10 pushbutton

+1/2CGA10 pushbutton

+1/2CGA10 pushbutton

+1/2CGA10 fuses / MCB in


CGA
+1/2CGA10 fuses / MCB in
CGA
+1/2CGA10 switch, 2 pos.

+1/2CGA10 pushbutton

+1/2CGA10 pushbutton

+1CGA10 EMDFL3V400

+1/2CGA10 KFD2-SR2-
2.W.SM
+1/2CGA10 Braun, D521

+1/2CGA10 Feedback of PSR-


SCP- 24UC/
+1/2CGA10 Feedback of PSR-
SCP- 24UC/
+1/2CGA10 Levelswitch

+1/2CGA10 Levelswitch

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 Motor Circuit


Breaker
+1/2CGA10 Motor Circuit
Breaker
+1/2CGA10 0

+1/2CGA10 Levelswitch

+1/2CGA10 Motor Circuit


Breaker
+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

#NV #NV

+1/2CGA10 THYNE 1

+1/2CGA10 GPC3

+1/2CGA10 GPC3

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0
+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 GPC3

+1/2CGA10 GPC3

+1/2CGA10 GPC3

+1/2CGA10 GPC3

+1/2CGA10 ESD
Button,auxiliary
+1/2CGA10 contact
positionswitch

+1/2CGA10 positionswitch

+1/2CGA10 positionswitch

+1/2CGA10 0

+1/2CGA10 Thermometer

+1/2CGA10 Thermometer

#NV #NV

+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

+1/2CGA10 THYNE 1

destination device

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100
+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 2 PT100 2-wire

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 PT100

#NV #NV
+1/2CGA10 Levelswitch

+1/2CGA10 Levelswitch

+1/2CGA10 differential
pressure switch
+1/2CGA10 pressure switch

+1/2CGA10 pressure switch

+1/2CGA10 Flowswitch

+1/2CGA10 Flowswitch

+1/2CGA10 Motor Circuit


Breaker
+1/2CGA10 Motor Circuit
Breaker
#NV #NV

+1CGA01 DRS C2A

+1CGA01 DRS C2A

+1CGA01 DRS C2A

+1/2CGA10 Buchholz Relay

+1/2CGA10 Buchholz Relay

+1/2CGA10 Pressure Safety


Valve
+1/2CGA10 green lamp

+1/2CGA10 red lamp

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CHA10 GPC3

+1/2AJA03 0

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CHA10 GPC3

+1/2CHA10 THYNE 1

+1/2CHA10 THYNE 1

+1/2CGA10 yellow lamp

+1/2CHA10 power contactor

+1/2CHA10 power contactor

+1/2CHA10 power contactor

+1/2CHA10 power contactor

+1/2CGA10 white lamp

+1/2MEX10 solenoid valve


GH010
+1/2CHA10 power contactor

+1/2CHA10 power contactor

+1/2CGA10 PSR-SCP-
24UC/ESA2/4X1/1
+1/2CGA10 PSR-SCP-
24UC/ESA2/4X1/1
+1/2MEX10 X
double controlled
GH010 solenoid valve
+1/2MEX10 solenoid valve
GH010
+1/2CGA10 safety valves

+0AJA01 0

+1/2CGA10 red lamp

+1/2CHA10 powerrelay

+1/2CGA10 KFD2-SR2-
2.W.SM
#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

+0AJA01 0

+1/2MEX10 double controlled


GH010 solenoid valve
#NV #NV

#NV #NV

+1/2CHA10 0

+DEIF 0

+1/2CGA10 0

+1/2CGA10 0

destination device

+1/2MEX10 proportional valve


GH010

#NV #NV

#NV #NV

#NV #NV

+1/2CGA10 96x96 indication


on turbine cont
+1/2CGA10 96x96 indication
on turbine con

+1/2CGA10 96x96 indication


on turbine cont

+1/2CGA10 96x96 indication


on turbine con

+1/2CGA10 PT100

#NV #NV

+1/2CGA10 PT100

+1/2CGA10 PT100

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0
#NV #NV

+1/2CGA10 horn

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 Flowswitch

+1/2CGA10 Flowswitch

+1/2CGA10 Flowswitch

+1/2CGA10 Flowswitch

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 Flowswitch

+1/2CGA10 Flowswitch

+1/2CGA10 positionswitch

+1/2CGA10 positionswitch

+1/2CGA10 0
+1/2CGA10 0

+1/2CGA10 0

+1/2CGA10 0

#NV #NV

+1/2CGA10 pushbutton

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

destination device

#NV #NV

+1CGA10 SINEAX

+1CGA10 SINEAX

+1CGA10 0

#NV #NV

+1CGA01 PT100

+1CGA01 PT100

+1CGA01 PT100
#NV #NV

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1/2CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 aux-contact

+1CGA10 aux-contact

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1/2CGA10 0

#NV #NV

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0

destination device

+60CGA10 0

+60CGA10 0

+1CGA10 0

+1CGA10 0

+1CGA10 0
#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

#NV #NV

+60LPB10 0

+60LPB10 0

+60LPB10 0

+60LPB10 0

+60LPB10 PT100

+60LPB10 PT100

+60LPB10 PT100
#NV #NV

+60LPB10 0

#NV #NV

#NV #NV

#NV #NV