Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Valve

Download as pdf or txt
Download as pdf or txt
You are on page 1of 136

D IR E C T IO N A L

CONTROL VALVES
H Y D R A U LIC C O M P O N E N T S

T E C H N I C A L C A T A L O G
CONTENT
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

DIRECTIONAL CONTROL VALVES

Mechanically operated
MECHANICALLY OPERATED 5
2/2 way directional valves KVC (NG 6) 5
2/2 way directional valves KVC-NV (NG 6) 7
4/2, 4/3 way directional valves KV (NG 6, 10) 9

HYDRAULICALLY OPERATED (AUTOMATIC) 17


4/2 way automatic directional valves PKV (NG 6, 10)) 17
4/2 way automatic directional valves PKV-...-T (NG 6) 21
4/2, 4/3 way directional valves KV (NG 6, 10) 25

Hydraulically operated
ELECTRICALLY OPERATED 29
2/2 way directional valves KV (NG 6) 29
3/2 way directional valves KVC (NG 4) 33
3/2 way directional valves KVC (NG 10) 37
4/2, 4/3 way directional valve KV-5KO (NG 6) 40
4/2, 4/3 way directional valve KV-5KO (NG 10) 46
4/2, 4/3 way directional valves type KV (NS 16) 53
4/2, 4/3 way directional valve KV-3KO (NG 6) 59
4/2, 4/3 way directional proportional valve KVP (NG 6) 65
4/2, 4/3 way bankable directional valves KVM (NG 6) 69
4/2, 4/3 way bankable directional valves KVM (NG 6) 71
Vertical stacking for KVM valves 77
Check valve KVM-NOV-6 81
Throttle with check valve KVM-NDV-6 83
Pressure relief valve KVM-VV-6 87
Electrically operated

Vertical stacking on valves KVM


with standard sandwich valves to ISO 4401 (NG 6) 91
Auxiliary control lever 93
Inlet plate OB-KVM-6 (NG 6) 95
End plate ZB-KVM-6 101
Fixing elements for mounting 103
6/2 way directional valve KV (NG 6) 105
6/2 way directional valves KV (NG 10) 109
6/2 way directional valves KV (NG 16) 113
6/2 way directional valves KV-6K (NG 6) 117
6/2 way directional valves KVH (NG 6) 121
6/2 way directional valves KVH (NG 10) 125
6/3 Way directional valves KV (NG 4) 129
8/3 way directional valves KV (NG 6) 131

27/01/14 3
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

4 27/01/14
MECHANICALLY OPERATED
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

2/2 way directional valves KVC (NG 6)

Mechanically operated
• NG 6
• Up to 250 bar [3 625 PSI]
• Up to 35 L/min [9.2 GPM]

KVC-2/2-K

Features Hydraulic symbol

Size 6
Flow rate L/min [GPM] 35 [9.2]
Operating pressure bar [PSI] 250 [3 625]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1 760]
Oil temperature range °C [°F] -20 to +70[-4 to 158]
Filtration ISO 4406-1999 19/17/14
Mass kg [lb] 1,2 [2.6]

Hydraulically operated
Seal type NBR seals for mineral oil HL, HLP, to DIN 51524

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].
Diff. pressure

Electrically operated

Flow

27/01/14 5
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

Stroke max.

Model code

K V C - 2 / 2 - K - -
*

Threaded connections
M12x1,5 No designation
G3/8 3/8

Special requirements to be briefly specified

6 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

2/2 WAY DIRECTIONAL VALVES KVC-NV (NG 6)

Mechanically operated
• NG 6
• Up to 210 bar [3 045 PSI]
• Up to 40 L/min [10.5 GPM]

KVC-2/2-NV-T

Features Hydraulic symbol

Size 6
Flow rate L/min [GPM] 40 [10.5]
Operating pressure bar [PSI] 210 [3 045]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1 760]
Oil temperature range °C [°F] -20 to +70[-4 to 158]
Filtration ISO 4406-1999 19/17/14
Mass kg [lb] 1,2 [2.6]

Hydraulically operated
Seal type NBR seals for mineral oil HL, HLP, to DIN 51524

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].
Diff. pressure

Electrically operated

Flow

27/01/14 7
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

Stroke max.

Model code

K V C - 2 / 2 - N V - T - -
*

Threaded connections
M18x1,5 No designation
G3/8 3/8

Special requirements to be briefly specified

8 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY DIRECTIONAL VALVES KV (NG 6, 10)

• NG 6, 10

Mechanically operated
• Up to 350 bar [5 076 PSI]
• Up to 60 L/min [15.8 GPM] for NG 6
• Up to 100 L/min [26.4 GPM] for NG 10

• Connecting dimensions to ISO 4401.

KV-4/3-5KO-6-R, KV-4/3-5KO-10-R

Operation Hydraulic symbols


Directional valves type KV with direct mechanical operation by means of a lever control the
direction of the hydraulic fluid medium flow. Spool types
These directional valves consist of a housing (1), control spool (2), control mechanism (3),
and return spring (4). In 4/3-way directional valves the centre position of the control spool
is the neutral position. The change-over to one of the operating positions "a" or "b" is done
by moving the operating pin lever (5) in such a manner that its acts on the control spool (2)
so as to clear corresponding flow ways and establish relevant links between ports, A, B, P,
and T.
On ceasing to apply force to the control mechanism (3), the return spring (4) push the
control spool into the neutral position.

Hydraulically operated
There are two types of operation:

1/ With control spool not held in the operating position (the control spool returns to neutral
position on ceasing to apply force to the control mechanism - type KV-../..-R).

2/ With control spool held (detent) in the operating position (the control spool remains in
the operating position on ceasing to apply force to the control mechanism lever - type
KV-../..-RA).

Electrically operated

27/01/14 9
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Size 6 10
Flow rate L/min [GPM] 60 [15.8] 100 [26.4]
P, A, B bar [PSI] 350 [5 076]
Operating pressure
T bar [PSI] 160 [2 320]
Viscosity range mm2 /s [SUS] 15 to 380 [69.5 to 1 760]
Oil temperature range °C [°F] -20 to+70 [-4 to 158]
Filtration NAS 1638 8
Mass kg [lb] 2,05 [4.52] 5,23 [11.53]
Mounting position Optional

Dimensions

Size 6 Size 10

3. Control mechanism on side ’’a’’ 3. Control mechanism on side ’’a’’


4/3 valves 4/3 valves
4/2 valves, spool types 51A 4/2 valves, spool types 51A
6. Fixing screws 4 pcs M5x30 to ISO 4762-10.9 6. Fixing screws 4 pcs M6x60 to ISO 4762-10.9
(by special order). (by special order).
Required tightening torque Md = 9 Nm. Required tightening torque Md = 15 Nm.
7. O-ring 9.25x1.78 7. O-ring 12.42x1.78
8. Valve cap. 8. Valve cap.
9. Nameplate. 9. Nameplate.

Required quality of the


mating surface.

10 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Cartridge throttle
If flow rates greater than permissible occur during change-over, a cartridge
throttle must be fitted into P-line of the directional valve.

Mechanically operated
P-Q Performance curves
Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Size 6 Size 10 Throttle


Diff. pressure

Diff. pressure

Diff. pressure
Flow Flow Flow

Hydraulically operated
Spool P-A P-B A-T B-T P-T
1 b,D b,D c,B c,C -
2 c,B c,B c,A c,A d,G
6 b,E b,E a,B a,B -
51A c,D b,D c,C a,B -

Electrically operated

27/01/14 11
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

K V - 4 / - 5 K O - - - - - -
*
Number of spool position
2 2
3 3
Special requirements to be
briefly specified
Size
Size 6 6
Size 10 10

Control spool held Seal type


NBR seals for mineral oil HL,HLP
No designation
R to DIN 51524
FPM seals for HETG, HEES, HEPG
E
to VDMA 24568 and ISO 15380
RA

Spool type Throttle mm [in]


No designation Without throttle in P line
D08 Throttle Ø 0,8 [0.03 dia.]
D10 Throttle Ø 1,0 [0.04 dia.]
1 D12 Throttle Ø 1,2 [0.05 dia.]

51A

12 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVES KV (NG 6, 10)

• NG 6, 10
• Up to 350 bar [5 076 PSI]
• Up to 60 L/min [15.8 GPM] for NG 6

Mechanically operated
• Up to 120 L/min [31.7 GPM] for NG 10

• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas).

KV-6/2-6-R..., KV-6/2-10-R...

Operation Hydraulic symbols

Directional valves type KV with direct mechanical operation by means of a lever control the Spool types
direction of the hydraulic medium flow.
They are mostly used as link between two consumers and the basic directional valve,
when we want to control both consumers alternately by means of one basic directional
valve.

There are two types of operation:

1/ With control spool not held in the operating position (the control spool returns to position
’’a’’ on ceasing to apply force to the mechanism - type KV-../..-R).

2/ With control spool held (detent) in the operating position (the control spool remains in
the operating position on ceasing to apply force to the control mechanism lever - type KV-
../..-RA).

Hydraulically operated
Mounting example

Electrically operated

27/01/14 13
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Size 6 10
Flow rate L/min [GPM] 60 [15.8] 120 [31.7]
With YZ bar [PSI] 350 [5 076]
Operating pressure
Without YZ bar [PSI] 160 [2 320]
Viscosity range mm2/s [SUS] 15 to 380 [69,5 to1 760]
Oil temperature range °C [°F] -20 to +70 [-4 to158]
Filtration NAS 1638 8
Mass kg [lb] 2,4 [5.3] 5,3 [11.7]
Mounting position Optional

14 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Dimensions

Size 6

Threaded connections M

Mechanically operated
A, B, C, D, P1, P2

Threaded LA=39,5 [1.55]( G3/8, M18x1,5)/37,5 [1.47] (G1/2, M22x1,5)


connection LC=23,5 [0.92] (G3/8, M18x1,5)/25,5[1.00] (G1/2, M22x1,5)

Hydraulically operated
Size 10

Threaded connections M
A, B, C, D, P1, P2

Threaded 1. Housing.
connection 2. Control mechanism.
3. Valve cap.
4. Name plate.
Electrically operated

27/01/14 15
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Size 6 Size 10

Diff. pressure

Flow

Model code

K V - 6 / 2 - - - - - -
*
Size
Size 6 6
Size 10 10

Control spool held

RA

Threaded connections (M ; YZ)


M18x1,5; M14x1,5 No designation
M22x1,5; M14x1,5 M22
Size 6 G3/8; G1/4 G3/8
G1/2; G1/4 G1/2
3/4-16 UNF-2B; 9/16-18 UNF-2B SAE 8
M22x1,5; M14x1,5 No designation
M27x1,5; M14x1,5 M27
Size 10 G1/2; G1/4 G1/2
G3/4; G1/4 G3/4
7/8-14 UNF-2B; 9/16-18 UNF-2B SAE 10

Drainage
Without YZ No designation
With YZ YZ

Seal type
NBR seals for mineral oil HL,HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified

16 27/01/14
HYDRAULICALLY OPERATED (AUTOMATIC)

POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2 WAY AUTOMATIC DIRECTIONAL VALVES PKV (NG 6, 10) )

• NG 6, 10
• Up to 210 bar [3 045 PSI]
• Up to 60 L /min [15.8 GPM]

• Indirect hydraulic operation.

Mechanically operated
• Connecting dimensions to ISO 4401.
• Provision of pressure setting for change - over.
• Automatic change - over from the other operating position.

PKV-6, PKV-10
Operation Hydraulic symbol

Indirectly, hydraulic - operated directional valves type PKV are used to control the
hydraulic fluid flow direction by an automatic change - over.

Mounting example

Hydraulically operated
Features

Size 6 10
Flow rate min/max L/min [GPM] 1/25 [0.3/6.6] 1/60 [0.3/15.8]
P, A, B bar [PSI] To 210 [3 045]
Operating pressure
T bar [PSI] To 40 [580]
Min. press. req. for autom. change over bar [PSI] 50 [725]
Change over pressure bar [PSI] 50 to210 [725 to3 045]
Electrically operated

15 to 380 [69.5 to 1 760]


Viscosity range mm2/s [SUS]

Oil temperature range °C [°F] -20 to +70 [-4 to158]


Filtration NAS 1638 8
Mass kg [lb] 2,6 [5.7] 3,2 [7.0]

27/01/14 17
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions
Size 6

Connection diagram and


connecting dimensions to
ISO 4401
1. Emergency manual override
2. Setting elements with protectivecap
3. O-ring 9.25 X 1.78
4. Fixing screws: 4 pcs M5 x 45 to EN
ISO 4762-10.9 must be ordered
separately.
Tightening torque Md = 9Nm
5. Nameplate

Size 10

Connection diagram and 1. Emergency manual override


connecting dimensions to 2. Setting elements with protectivecap
ISO 4401 3. O-ring 12 X 2
4. Fixing screws: 4 pcs M6 x 55 to EN
ISO 4762-10.9 must be ordered
separately.
Tightening torque Md = 14Nm
5. Nameplate

Required quality of
the mating surface.

18 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Size 6 Size 10

Mechanically operated
Pressure drop
Pressure drop

Flow Flow

Model code

P K V - - -
*

Hydraulically operated
Size
Size 6 6
Size 10 10

Seal type
NBR seals for mineral oil HL, HLP, to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified


Electrically operated

27/01/14 19
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

20 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2 WAY AUTOMATIC DIRECTIONAL VALVES PKV-...-T (NG 6)

• NG 6
• Up to 210 bar [3 045 PSI]
• Up to 30 L /min [7.9 GPM]

Mechanically operated
• Connecting dimensions to ISO 4401.
• Automatic, load - independent reversal.
• Predefined actuator direction at start - up.

PKV-6-T, PKV-6-T-G

Operation Hydraulic symbol


These valves reverse the movement of an actuator every timethe flow through the valve
stops. Preferential starting is P  Band A  T position. The spool is moved by two springs PKV-6-T
andlocked by unbalanced pressure inside valve. When no moreflow is crossing the valve,
the spool changes the positioninverting the direction of the actuator. These valves are
mostlyused to control the movement compactors or system where it isnot possible to use
electrical device.

About the spindle for the PKV-6-T-G valves:

The spindle for the PKV-6-T-G valves is used just to set the system pressure limiter. To set PKV-6-T-G
the maximum pressure you have to block the self-reversing function.

Hydraulically operated
Procedure to set a pressure on the system pressure limiter:

1/ Switch off the pump or reduce pressure to minimum (10 bar max).
2/ To set the system pressure limiter first block the automatic reversal of the valve.
Remove the dome nut and turn the offsetting spindle clockwise until it hits its inner end Mounting example
spool. The spool is now clamped P to B and A to T.
3/ Start the pump and set the required pressure.
4/ After that stop again the pump.
5/ Turn the offsetting spindle anticlockwise until it hits its outer end stop then put the dome
nut back.

Never turn the offsetting spindle when the valve is pressurized over
10 bar [145 PSI]. This can cause seal damage. If necessary switch off
the pump.

System
pressure
Offsetting limiter
spindle

Dome nut
Electrically operated

Seal

27/01/14 21
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Size 6
Flow rate min/max L/min [GPM] 3/30 [0.8/7.9]
Operating pressure P, A, B bar [PSI] 50 to 210 [725 to 3 045]
Max. pressure T bar [PSI] 40 [580]
Viscosity range mm2 /s [SUS] 20 to 200 [92.7 to 926.8]
Oil temperature range °C [°F] -20 to +60 [-4 to 140]
Filtration NAS 1638 8
PKV-6-T 1,3 [2.8]
Mass kg [lb]
PKV-6-T-G 1,4 [3.1]

Dimensions

Required quality of
the mating surface.

Connection diagram and connecting dimensions to ISO 4401.

Tightening torque
max. 2Nm

Spindle

PKV-6-T PKV-6-T-G

4 x fixing screws M5x30 to DIN EN ISO 4762-10.9 must be ordered separately.


Required tightening torque Md = 9 Nm [79.65 in.lbf].

22 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves


Measured at 50°C [122°F] and
viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Pressure drop

Flow

Model code

P K V - 6 - T - - -
*

Hydraulically operated
Offsetting spindle
Without offsetting spindle No designation
With offsetting spindle G

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified


Electrically operated

27/01/14 23
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

24 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY DIRECTIONAL VALVES KV (NG 6, 10)

• NG 6, 10
• Up to 350 bar [5 076 PSI]

Mechanically operated
• Up to 80 L/min [21.1 GPM]
• Up to 130 L/min [34.3 GPM]

• Direct hydraulically operation.


• Connecting dimensions to ISO 4401.
• Threaded connections to ISO 1179.

KV-4/3-5KO-6-H, KV-4/3-5KO-10-H

Operation Hydraulic symbols

The KV-...-H is a hydraulically controlled 4/3 or 4/2 way directional control valve. The valve Spool types
is operated by the pilots ports X and Y via the connection of an external pilot pipe direct on
the valve body.

The minimum pilot pressure must be ensured for all operating conditions of the directional
valve.

Hydraulically operated
Features

Size 6 10
Flow rate L/min [GPM] 80 [21.1] 130 [34.3]
Ports A, B, P bar [PSI] 350 [5 076]
Operating pressure
Ports X, Y, T bar [PSI] 210 [3 045]
Electrically operated

Pilot supply pressure min. bar [PSI] 10 [145]


2 15 to 380 [69.5 to 1 760]
Viscosity range mm /s [SUS]
Oil temperature range °C [°F] -20 to +70[-4 to 158]
Filtration NAS 1638 8
Mass kg [lb] 1,4 [3.1] 4,0 [8.8]
Mounting position Optional

27/01/14 25
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions
Size 6 Size 10

1. Threaded connection X (Y) - G1/4 1. Threaded connection X (Y) - G1/4


2. Fixing screws 4 pcs M5x30 to ISO 2. Fixing screws 4 pcs M6x60 to ISO
4762-10.9 (by special order) Required 4762-10.9 (by special order) Required
tightening torque Md = 9Nm tightening torque Md = 15Nm
3. O-ring 9.25 x 1.78 3. O-ring 12.42 x 1.78
4. Nameplate. 4. Nameplate.

Required quality of the


mating surface.

Cartridge throttle

If flow rates greater than permissible occur during change-over, a cartridge


throttle must be fitted into P-line of the directional valve.

26 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Size 6 Size 10

Mechanically operated
Diff. pressure
Diff. pressure

Flow Flow

Spool P-A P-B A-T B-T P-T Spool P-A P-B A-T B-T P-T
1 8 8 6 6 - 1 1 1 5 5 -
2 5 5 4 4 1 2 3 3 2 7 8
6 5 5 9 9 - 6 1 1 2 2 -
51A 5 5 1 1 - 51A 1 1 3 3 -

Model code

K V - 4 / - 5 K O - - H - - -
*

Hydraulically operated
Number of control spool position
Two positions 2
Three positions 3

Size
Size 6 6 Special requirements to be
Size 10 briefly specified
10

Hydraulically operated

Spool types
Seal type
1
NBR seals for mineral oil
No designation
HL,HLP to DIN 51524
(NS10) 2 FPM seals for HETG, HEES,
E HEPG to VDMA 24568 and
ISO 15380
Electrically operated

(NS 6) 2

51A

Throttle mm [in]
51B
No designation Without throttle in P line
D08 Throttle Ø 0,8 [0.03 dia.]
D10 Throttle Ø 1,0 [0.04 dia.]
D12 Throttle Ø 1,2 [0.05 dia.]

27/01/14 27
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

28 27/01/14
ELECTRICALLY OPERATED
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

2/2 WAY DIRECTIONAL VALVES KV (NG 6)

• NG 6
• Up to 210 bar [3045 PSI]
• Up to 30 L/min [7.9 GPM]

Mechanically operated
• Direct in-line mounting.
• Threaded connections to ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Hermetically sealing at closed flow path.
• No STICK-SLIP effect even after a prolonged dwell time under pressure.
• Plug-in solenoid connector to ISO 4400.
• Protection of solenoid IP65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-2/2-6-S-..

Operation Hydraulic symbols


Directly-operated directional seat valves KV are used forthe control of direction of
hydraulic fluid.

KV-2/2-6-S-A-...

In the start control position a, the return spring (4) holds the ball(2) in its open position, thus
freeing the flow path betweenports A and B. The change-over into the control position b
isaccomplished by energizing the solenoid (3), whereby the ball(2) is pushed against the
seat (1). The hydraulic fluid on port Ais under pressure.

KV-2/2-6-S-B-...

Hydraulically operated
The hydraulic fluid on port A in the start control position a isunder pressure. The return
spring (4) pushes the ball (2)against its seat (1). The change-over to the control position
bis performed by energizing the solenoid (3), thus freeing theflow path between ports
A and B.

The change-over can also be done manually by pressing theemergency manual Mounting example
override (5).

Electrically operated

27/01/14 29
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] 30 [7,93]
Operating pressure bar [PSI] 210 [3045,79]
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Filtration NAS 1638 8
Mass kg [lb] 2,2 [4,85]

Electrical
Supply voltage V 12, 24, 48, 110, 230 DC or AC
Power W 29 *
Intermittence continuous
Ambient temperature °C [°F] To +50 [To +122]
Coil temperature °C [°F] To +180 [To +356]
Duty cycle min-1 250
* 12V supply voltage - 36W

Dimensions

KV-2/2-6-S-A-

3. Solenoid ’’b’’ MR-045.


5. Emergency manual override.
6. Nameplate.

KV-2/2-6-S-B-

30 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32


mm2/s [148 SUS].

Valid for flow direction A to B.


Symbol A

Mechanically operated
Pressure drop
Symbol B

Flow

Model code

K V - 2 / 2 - 6 - S - - - -
*
Manual override option
Emergency manual override No designation
Special requirements to be
Manual override with rubber cover G briefly specified
Lockable manual override C

Hydraulically operated
Spool type
Seal type
NBR seals for mineral oil HL,
A No designation
HLP, to DIN 51524
FPM seals for HETG, HEES,
E HEPG to VDMA 24568 and
B ISO 15380

Supply voltage Threaded connections


Direct voltage Alternating voltage G 3/8
No designation
12 V 12 DC 12 AC SAE 8 3/4-16 UNF-2B
24 V No designation 24 AC
48 V 48 DC 48 AC
110 V 110 DC 110 AC
220 V 220 DC - Overvoltage protection
230 V - 230 AC* No designation overvoltage protection
Electrically operated

T With overvoltage protection


- Alternating voltage solenoids are fitted with a bridge rectifier
-With solenoids of over 48 V an earthing clampto ISO 4400 must be
connected.
To fulfil EMC (89/336/EEC) a capacitor must be built in.

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP junior timer without connector M
Deutsch V

27/01/14 31
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

32 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

3/2 WAY DIRECTIONAL VALVES KVC (NG 4)

• NG 4
• Up to 160 bar [2 320 PSI]
• Up to 16 L/min [4.2 GPM]

Mechanically operated
• Plug-in connector for solenoids to ISO 4400.
• Optimized flow paths for low losses of pressure.
• Wet pin solenoid with interchangeable coil.
• Manual emergency control.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KVC2-3/2-4-47B, KVC-3/2-4-47B

Features Hydraulic symbol

Hydraulic Single: KVC-3/2-4-47B


Size 4
Flow rate L/min [GPM] 16 [4.2]
Operating pressure bar [PSI] 160 [2 320]
Viscosity range mm2/s [SUS] 15 to 380 [69.5to 1760]
Oil temperature range °C [°F] -20 to+70 [-4 to 158] Double: KVC2-3/2-4-47B

Filtration ISO 4406-1999 19/17/14

Hydraulically operated
KVC-3/2-4 1,6[3.5]
Mass kg [lb]
KVC2-3/2-4 3,5 [7.7]

Electrical
Supply voltage V 12, 24
Power W 29 *
Switch-on time** ms 50 to 80
Switch-off time** ms 30 to 55
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to50 [122]
Coil temperature °C [°F] to 180 [356]
Duty cycle Continuous
* 12 V supply voltage - 36 W.
** The switching-on and off times apply to 24 V DC solenoids
Electrically operated

27/01/14 33
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

KVC-3/2-4 KVC2-3/2-4

Diff. pressure
Diff. pressure

Flow Flow

Dimensions

KVC-3/2-4-47B KVC2-3/2-4-47B

Emergency manual override Emergency manual override

34 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Model code

K V C - 3 / 2 - 4 - 4 7 B - - - -
*

Mechanically operated
Hydraulic symbol
Simple No designation
Double 2
Special requirements to
be briefly specified
Working ports
Three working ports 3

Number of control spool position


Two positions 2 Seal type
NBR seals for mineral oil
No designation
HL,HLP to DIN 51524
Size
PM seals for HETG,
Size 4 E HEES, HEPG to VDMA
24568 and ISO 15380

Spool type

Hydraulically operated
Supply voltage
Direct voltage 24V 24 DC
Direct voltage 12V 12 DC

Manual override option


Emergency manual
No designation
override
Connector type Manual override with
G rubber cover
EN 175301-803 without signal lamp No designation
C Lockable manual override
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP Junior timer without connector M
Deutsch V

Overvoltage
Without overvoltage protection No designation
With overvoltage protection T
Electrically operated

Threaded connections A, B, P
M14x1,5; - No designation
G1/4 ; - 1/4
9/16-18 UNF-2B ; 9/16-18 UNF-2B SAE 6

27/01/14 35
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

36 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

3/2 WAY DIRECTIONAL VALVES KVC (NG 10)

• NG 10
• Up to 350 bar [5 076 PSI]

Mechanically operated
• Up to 100 L/min [26.4 GPM]

• Direct in-line mounting.


• Plug-in connector for solenoids to ISO 4400.
• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP65 to EN 50529 / IEC 60529.

KVC-3/2-10

Operation Hydraulic symbol


Directional valves type KVC-3/2-10 with direct solenoid operation are used to control the
direction of hydraulic fluid flow.
Type KVC-3/2-10 is a reduced version of type KV-6/2. It is used for alternate control of two
one-pipe working units (e.g. Plunger) with common, main directional valve.

It is also very proper as bypass valve.

The change-over can also be done manually by pressing the emergency manual override.

Hydraulically operated
B
P Mounting example

Electrically operated

27/01/14 37
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 10
Without drainage 60 [15.8]
Flow rate L/min [GPM]
With drainage 100 [26.4]
Without drainage 250 [3 625]
Operating pressure bar [PSI]
With drainage 350 [5 076]
Oil temperature range °C [°F] -20 to +70 [-4 to+158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Mounting position Optional
Without drainage 5,6 [12.34]
Mass kg [lb]
With drainage 7,1 [15.65]
Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
Power W 45
Switching frequency 1/h 15000
Ambient temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

Dimensions
[0.59]
15

L7 B Dimensions Without YZ With YZ


L4 11 ±0.2 L 201 [7.91] 210 [8.27]
Pg 9

[0.43 ±0.01dia.] z=2 L1 85 [3.34] 94 [3.70]


P
L2 29,5 [1.16] 31,5 [1.24]
H

A L3 55,5 [2.18] 62,5 [2.46]


L4 42,5 [1.67] 47 [1.85]
L5 19,5 [0.76] 18 [0.71]
H1

L6 46 [1.81] 40 [1.57]
H5

L7 - 79,5 [3.13]
H 104 [4.09] 105 [4,13]
H4

YZ
H1 67 [2.63] 74 [2,91]
H2 73 [2,87] 90 [3,54]
6.6 L5 L6 ±0.2 [L6 ±0.01] 108 [4.25]
[0.26 dia.] H3 46 [1,81] 66 [2,60]
L1 122 [4.80] (with manual override)
H4 - 33 [1,30]
L H5 50,5 [1,98] 31 [1,22]

9 8 7 3 6 5
L3
B 3. Solenoid "b" MR-060
5. Emergency manual override
P 6. Plug-in connector "b" -black
7. Fixing screws:
]

-without YZ: 2 x M6x60 to ISO 4762-10.9


±0.01

-with YZ: - 2 x M6x40 to ISO 4762-10.9


H3 ±0.2 [H3
H2

8. Nameplate
9. Valve cap

L2 A Threaded connection
z=3

38 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Without YZ With YZ

Mechanically operated
Pressure drop

Flow

Model code

K V C - 3 / 2 - 10 - - 41B - - - - -
*

Manual override option


Special requirements to be

Hydraulically operated
Emergency manual override No designation briefly specified
Manual override with rubber cover G
Lockable manual override C

Spool type Seal type


NBR seals for mineral oil HL,
No designation
41B HLP to DIN 51524
FPM seals for HETG, HEES,
E HEPG to VDMA 24568 and
ISO 15380

Supply voltage
Direct voltage 24V No designation
Direct voltage 12V 12 DC Drainage

No designation Without YZ
Connector type
175301-803 without signal lamp No designation
YZ With YZ
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
Electrically operated

AMP Junior timer without connector M


Deutsch V

Threaded connections A,B,P ; YZ


No designation M18x1,5 ; -
Overvoltage M22 M22x1,5 ; -
Without overvoltage protection No designation
M20 M20x1,5 ; -
With overvoltage protection T 3/8 G3/8; -
1/2 G1/2; -
3/4 G3/4; -
3/4 G3/4; G1/4
SAE 12 1 1/16-12 UNF-2B ; 9/16-18 UNF-2B

27/01/14 39
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

4/2, 4/3 WAY DIRECTIONAL VALVE KV-5KO (NG 6)

• NG 6
• Up to 350 bar [5 076 PSI]
• Up to 75 L/min [19.8 GPM]

• Connection diagram and connecting dimensions to ISO 4401.


• Plug-in connector for solenoids to ISO 4400.
• 5-chamber model with good spool guidance.
• Optimized flow paths for low losses of pressure.
• Adjustment of the switching time.
• Wet pin solenoid with interchangeable coil.
• Manual emergency control.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-4/3-5KO-6

Operation Hydraulic symbols

Directional valves type KV with direct solenoid operation control the direction of the hydraulic Spool types
medium flow.

These directional valves consist of a housing (1), a control spool (3), and one solenoid (2) with
two return springs (4) in 4/2-way directional valves, and two solenoids (2) with two return
springs (4) in 4/3-way directional valves. In 4/3-way directional valves the centre position of the
control spool is the neutral position. The change-over to the operating position (a) and (b) is
done by energizing the solenoids (2) "a" and "b" respectively, whereby the solenoid plunger
acts on the control spool (3) via the operating pin (5), thus clearing the corresponding flow ways
and establishing relevant links between ports A, B, P, and T.

When the solenoid (2) is de-energized, the control spool (3) is returned to its neutral position by
the return spring (4). The change-over can be done manually by pressing the emergency
manual override (6).

KV-4/2-5KO-6-81

Directional valve with two operating position, two solenoids without springs allow the control
spool to be held in the operating position (detent). The control spool remains in the operation
position also when the solenoids are de-energized.

40 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Features

Hydraulic
Size 6
Flow rate L/min [GPM] see P-Q curves
Ports A, B, P bar [PSI] 350 [5 076]

Mechanically operated
Operating pressure
Port T bar [PSI] 250 [3 625]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1 760]
Oil temperature range °C [°F] -20 to +70[-4 to 158]
Filtration NAS 1638 8
4/2 1,9 [4.2]
Mass kg [lb]
4/3 2,7 [5.9]
Mounting position Optional

Electrical
Direct 12, 24, 48
Supply voltage V
Alternating 110, 230
Power W 29 *
Switch-on time** ms 50 to 80
Switch-off time** ms 30 to 55
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to 50 [122]
Coil temperature °C [°F] to180 [356]

Hydraulically operated
Duty cycle Continuous
* 12 V supply voltage - 36 W.
** The switching-on and off times apply to 24 V DC solenoids.

P-Q Performance curves P-Q Operating limits


2
Measured at 50°C [122°F] and viscosity of 32 mm /s [148 SUS]. Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].
Diff. pressure
Diff. pressure

Electrically operated

Flow
Flow
The operating limits of the valve are
determined at a voltage 10% below
the nominal rating. The curves refer
Flow path Spool Kurve to application with symetrical flow
Spool P-A P-B A-T B-T P-T 1 throw the valve (P-A and B-T). In the
1 case of asymetric flow (e.g. one part
1 8 8 6 6 - 2 4 not used) reduced values may result.
2 5 5 4 4 1 3 3
Note: For valves with adjustment of
3 8 8 7 7 - 6 3 the switching time reduced values of
6 the operating limits may result.
5 5 9 9 - 81 1
81 5 5 1 1 - 51A, 51B 1
51A, 51B 5 5 1 1 - 41A, 41B 2
41A, 41B 7 7 - - -

27/01/14 41
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

With hand operation - add


letter G before spool type in
ordering code.

KV-4/2-5KO-6

Max. torque 30 Nm

Max. torque Connection diagram and


connecting dimensions to
ISO 4401.

KV-4/3-5KO-6

Max. torque 30 Nm

Required quality of the


Max. torque
mating surface.

KV-4/2-5KO-6-81

Cartridge throttle

If flow rates greater than permissible occur during change-over, a


cartridge throttle must be fitted into P-line of the directional valve.

Installation
The directional control valve must be installed horizontally (Nameplate on top). If this is not the case, the valve must be removed for venting.
Unscrew the vent screw. Move the spool alternately to the switching positions a and b until no more bubbles appear at the screw hole. The oil
must be visible at the screw hole. Missing oil should be refielled with an oilcan, drop by drop. Screw in the vent screw.A constant or short time
static oil pressure of at least > 4 bar must prevail at connection T of the directional control valve to maintain the oil pressure in the spring
chambers. If this is not the case, the preloaded oil volume of the restricted valve would leak into the T channel through the leakage section of the
control spool shoulders.The dampening constancy also depends on the constancy of the oil viscosity.
For this reason the dampening effect should always be adjusted with the system at operational temperature.

42 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Function drawing

KV-4/3-5KO-6
(KV-4/2-5KO-6)

Mechanically operated
KV-4/2-5KO-6-81
Vent screw

Hydraulically operated
KV-4/3-5KO-6-2
Vent screw

1. Solenoid "a" - MR-045


2. Solenoid "b" - MR-045
3. Fixing screws 4 pcs M5 x 30 to ISO 4762
-10.9 must be ordered separately.
Required tightening torque Md = 9 Nm
Vent screw 4. Plug-in connector "a" - grey
Electrically operated

5. Plug-in connector "b" - black


KV-4/2-5KO-6-UD 6. Emergency manual override
7. O-ring 9,25 x 1,78
8. Valve cap
9. Nameplate
10. Constant action restrictor

27/01/14 43
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

K V - / - 5 K O - 6 -

Working ports
Three working ports 3
Four working ports 4

Number of control spool positions


Two positions 2
Three positions 3

Manual override option


Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C

Spool types

1 1A 1B 81

2 2A 2B

3 3A 3B

6 6A 6B

51A 51B

41A 41B

Port T in the valves with spool type 41A and 41B to be used as lekage line.

Valves with adjustment of the switching time - a constant or short - time static
oil pressure of at least  4 bar [58 PSI] must prevail at connection T of the
directional control valve to maintain the pressure in the spring chambers.

44 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

- - - - -
*

Mechanically operated
Supply voltage
Direct voltage Alternating voltage
12 V 12 DC 12 AC
24 V No designation 24 AC
48 V 48 DC 48 AC
110 V 110 DC 110 AC
230 V 230 DC 230 AC*

Alternating voltage solenoids are fitted with a bridge rectifier


With solenoids of over 48 V an earthing clampto ISO 4400 must
be connected
*To fulfil EMC (89/336/EEC) a capacitor must be built in.

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP junior timer without connector M
Deutsch V

Hydraulically operated
Overvoltage protection
Without overvoltage protection No designation
With overvoltage protection T

Throttle mm [in]
Without throttle in P line No designation
Throttle Ø 0,8 [0.03 dia.] D08
Throttle Ø 1,0 [0.04 dia.] D10
Throttle Ø 1,2 [0.05 dia.] D12

Constant action restrictor


Without restrictor No designation
With restrictor Ø 0,35 [0.01 dia.] UD

Seal type
NBR seals for mineral oil HL,HLP to
Electrically operated

No designation
DIN 51524
FPM seals for HETG, HEES, HEPG to
E
VDMA 24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 45
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

4/2, 4/3 WAY DIRECTIONAL VALVE KV-5KO (NG 10)

• NG 10
• Up to 350 bar [5 076 PSI].
• Up to 120 L/min [31.7 GPM].

• Connection diagram and connecting dimensions to ISO 4401.


• Plug-in connector for solenoids to ISO 4400.5-chamber model with good spool guidance.
• Optimized flow paths for low losses of pressure.
• Adjustment of the switching time.
• Wet pin solenoid with interchangeable coil.
• Manual emergency control.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.

KV-4/3-5KO-10

Operation Hydraulic symbol

Directional valves type KV with direct solenoid operation control the direction of the hydraulic Spool types
medium flow.

These directional valves consist of a housing (1), a control spool (3), and one solenoid (2) with
two return springs (4) in 4/2-way directional valves, and two solenoids (2) with two return
springs (4) in 4/3-way directional valves. In 4/3-way directional valves the centre position of the
control spool is the neutral position. The change-over to the operating position (a) and (b) is
done by energizing the solenoids (2) "a" and "b" respectively, whereby the solenoid plunger
acts on the control spool (3) via the operating pin (5), thus clearing the corresponding flow
ways and establishing relevant links between ports A, B, P, and T.

When the solenoid (2) is de-energized, the control spool (3) is returned to its neutral position
by the return spring (4). The change-over can be done manually by pressing the emergency
manual override (6).

KV-4/2-5KO-10-81

Directional valve with two operating position, two solenoids without springs allows the control
spool to be held in the operating position (detent). The control spool remains in the operation
position also when the solenoids are de-energised.

1 3 4 5 2 6

A B

T A P B T

46 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Features

Hydraulic
Size 10
Flow rate L/min [GPM] see P-Q curves
Ports A, B, P bar [PSI] 350 [5 076]

Mechanically operated
Operating pressure
Port T bar [PSI] 250 [3 625]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1 760]
Oil temperature range °C [°F] -20 to+70 [-4 to 158]
Filtration NAS 1638 8
Mass 4/2 6,5 [14.3]
kg [lb]
4/3 7,3 [16.1]
Mounting position Optiona

Electrical
Direct 12, 24, 48
Supply voltage V
Alternating 110, 230
Power W 45
Switch-on time* ms 70 to 95
Switch-off time* ms 40 to 80
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to 50 [122]
Coil temperature °C [°F] to 180 [356]

Hydraulically operated
Duty cycle Continuous
* The switching-on and off times apply to 24 V DC solenoids.

P-Q Performance curves P-Q Operating limits


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS]. Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].
Diff. pressure

Pressure

Flow
Flow
Electrically operated

Flow path Spool curve The operating limits of the valve are
Spool P-A P-B A-T B-T 1 1 determined at a voltage 10% below the
1 1 1 5 5 - 2 4 nominal rating. The curves refer to
2 3 3 2 7 8 3 5 application with symetrical flow throw the
valve (P-A and B-T). In the case of
3 6 6 3 4 - 6 3 asymetric flow (e.g. one part not used)
6 1 1 2 2 - 9 6 reduced values may result.
9 6 6 2 2 - 81 1
Note: For valves with adjustment of the
81 1 1 3 3 - 51A, 51B 1
switching time reduced values of the
51A, 51B 1 1 3 3 - 41A, 41B 2 operating limits may result.
41A, 41B 6 6 - - -

27/01/14 47
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions
122 [4.80]
0.04]

T T
[2.44 dia.]

46 [1.81]
62
[2.76

KV-4/2-5KO-10
A B
P
70

With hand operation - add letter G


24.5 54 [2.13] before spool type in ordering code.
Max. torque 6 Nm [0.96]
ca. 219[8.62]
.Connection diagram and connecting
dimensions to ISO 4401.
ø 11[0.43 dia.]
A B
ca. 112 [4.41]

50.5 [1.99]
83 [3.27]

KV-4/3-5KO-10

ø 6.6 [0.26 dia.] S=27 [1.06]


ca. 108 [4.25] 103 [4.06] Max. torque 50 Nm

ca. 319[12.56]

A B
Pg9.

KV-4/2-5KO-10-81

17.5 S=27 [1.06]


[0.69] ca. 336.5 [13.23] Max. torque 50 Nm

0,01/100mm

Rmax4 Required quality of the


mating surface.

Cartridge throttle

If flow rates greater than permissible occur during change-over, a


cartridge throttle must be fitted into P-line of the directional valve.

Installation
The directional control valve must be installed horizontally (Nameplate on top). If this is not the case, the valve must be removed for venting.
Unscrew the vent screw. Move the spool alternately to the switching positions a and b until no more bubbles appear at the screw hole. The oil
must be visible at the screw hole. Missing oil should be refielled with an oilcan, drop by drop. Screw in the vent screw.A constant or short time
static oil pressure of at least > 4 bar must prevail at connection T of the directional control valve to maintain the oil pressure in the spring
chambers. If this is not the case, the preloaded oil volume of the restricted valve would leak into the T channel through the leakage section of the
control spool shoulders.The dampening constancy also depends on the constancy of the oil viscosity.For this reason the dampening effect
should always be adjusted with the system at operational temperature.

48 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Function drawing

4 1 9 7 3 8 2 5 6

KV-4/3-5KO-10

Mechanically operated
A B (KV-4/2-5KO-10)

1. Solenoid "a" - MR-060 4. Plug-in connector "a" - grey


2. Solenoid "b" - MR-060 5. Plug-in connector "b" - black
3. Fixing screws 4 pcs M6 x 60 to ISO 6. Emergency manual override
4762 -10.9 must be ordered separately. 7. O-ring 12,42 x 1,87
Required tightening torque Md = 15 Nm 8. Valve cap
9. Nameplate
10. Constant action restrictor

Hydraulically operated
KV-4/2-5KO-10-81
A B

Vent screw

KV-4/3-5KO-10-2-UD
A 10 B (KV-4/2-5KO-10-2-UD)
Electrically operated

27/01/14 49
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

K V - / - 5 K O - 10 -

Working ports
Three working ports 3
Four working ports 4

Number of control spool position


Two positions 2
Three positionsTwo positions 3

Manual override option


Emergency manual override No designation
Manual override with rubber cover
G
Lockable manual override C

Spool types

1 1A 1B 81

2 2A 2B

3 3A 3B

6 6A 6B

51A 51B

41A 41B

Port T in the valves with spool type 41A and 41B to be used as lekage line.

Valves with adjustment of the switching time - a constant or short - time static oil pressure
of at least > 4 bar [58 PSI] must prevail at connection T of the directional control valve to
maintain the pressure in the spring chambers.

50 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

- - - - -
*

Mechanically operated
Supply voltage
Direct voltage Alternating voltage
12 V 12 DC 12 AC
24 V No designation 24 AC
48 V 48 DC 48 AC
110 V 110 DC 110 AC
230 V 230 DC 230 AC*

- Alternating voltage solenoids are fitted with a bridge rectifier


- With solenoids of over 48 V an earthing clamp to ISO 4400 must
be connected
*To fulfil EMC (89/336/EEC) a capacitor must be built in.

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP junior timer without connector M
Deutsch V

Hydraulically operated
Overvoltage protection
Without overvoltage protection No designation
With overvoltage protection T

Throttle mm [in]
Without throttle in P line No designation
Throttle Ø 0,8 [0.03 dia.] D08
Throttle Ø 1,0 [0.04 dia.] D10
Throttle Ø 1,2 [0.05 dia.] D12

Constant action restrictor


Without restrictor No designation
With restrictor Ø 0,35 [0.01 dia.] UD
Electrically operated

Seal type
NBR seals for mineral oil HL,HLP to
No designation
DIN 51524
FPM seals for HETG, HEES, HEPG to
E
VDMA 24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 51
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

52 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY DIRECTIONAL VALVES TYPE KV (NS 16)

• NG 16
• To 350 bar [5 076 PSI]
• To 300 L/min [79 GPM]

Mechanically operated
• Indirect, solenoid, and mechanical (by lever) operation.
• Connection diagram and connecting dimensions to ISO 4401.
• Plug-in solenoid connector to ISO 4400.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-4/3-16-

Operation Hydraulic symbols


Directional valves type KV with indirect, solenoid-hydraulic operation control the hydraulic
fluid flow direction. Spool types
These valves consist of the main valve (1), a control spool (2), two return springs (3) in
4/3-way valves and none in 4/2-way valves, a double throttle check/valve (4) and a
pilot valve (5).
The pilot valve (5) is connected with the pressure chambers (8) via the pilot line (7).
Feeding of the pilot valve oil is either or external (via the port "x"). Change-over of the
control spool to one of the operating position is activated by the introduction of oil via the
pilot valve (5) into one of the pressure chambers (8). A pressure rise in chambers provokes
the movement of the control spool (2). Suitable links between ports A,B,P,T according to
spool types are established as set forth in the table.
When the solenoid of the pilot valve (5) are de-energized a link between the pressure
chamber (8) and the return line "y" for the pilot oil discharge is established. A pressure

Hydraulically operated
drop in the chamber actuates the main valve return spring (3) which automatically return
the control spool to the neutral position.
Dischange of the return pilot oil from the pressure chambers is either internal or external
(via the port "y").
Manual change-over of the main valve is also possible by pressing the emergency manual
override (9).
Indirect directional valves can also be provided with a manual pilot valve. These valves are
manually operated by moving the operating lever.

Electrically operated

27/01/14 53
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Flow rate l/min [GPM] 300 [79.2]


Ports A, B, P 350 [5076.3]
Operating pressure bar[PSI]
Port T 250 [3625.9]
Pilot oil pressure (x-external) bar [PSI] 50-250 [725.2-3625.9]
In valve types with internal pilot oil supply (x) the
spool types 2, 3, and 4 are possible only when the oil
Pilot oil pressure (x-internal) flow in the direction from P towards T achieves the
Pre-load valve is fitted into P-port of the main valve
Without Pre-load valve in the P-port of the main valve flow rate
Q = 150 L/min [39.6 GPM], with the control spool in
the centre position.
Oil temperature range °C [°F] -20 to +70 [-4 to 158]
Viscosity range mm2/S 15 to 380
3 7,8 [0.47]
Required pilot oil volume cm [cu.in] 2 positions valve
3 positions valve 3,9 [0.24]
Main valve 8 [17.6]
4/3 pilot valve 2,5 [5.5]

Mass Kg [lb] 4/2 pilot valve 2,2 [4.8]


Throttle/check valve 1,45 [3.2]
Pressure reducing 1,70 [3.7]
valve
Mounting position Optional, horizontal for spool types 4/2
Switch-on time 3 positions valve 60
(ms)
Solenoid change-over from the operating to the centre position 2 positions valve 85
Switch-off time 3 positions valve 45
(ms)
Solenoid change-over from the operating to the centre position 2 positions valve 50
Filtration NAS 1638 8
Ambient temperature range °C [°F] +50 [122]
Coil temperature range °C [°F] +180 [356]
Power W 29 (12V supply voltage - 36W)
Voltage V 12, 24, 48, 110, 230
The switch-on and switch-off times apply to 24 V DC solenoids.

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].


Throttle
Diff. pressure
Diff. pressure

Flow Flow

Spool type P-A P-B A-T B-T P-T


1, R1, 51B, 51A, F51, R51 e e e f -
2, R2 a b c e f See Model Code for
3, R3 b b c d - spool type choice.
4, R4 b c c e -
5, R5 b c c e -
6, R6 b c d e -

54 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Cartridge throttle Pre-load valve

Pilot valve In valves with a low pressure bypass


If the pilot oil supply rate (x) is greater than and internal pilot oil feed, minimum
permissible a cartridge throttle shall be pilot pressure is obtained by installing
fitted into the P line of the directional valve. a pre-load valve in the P-port of the
main valve.
The cracking pressure is approx.

Mechanically operated
4,5 to 6 bar [65 to 87 PSI].
Main valve

Pressure reducing valve Throttle check valve


The pressure reducing valve used when the pilot oil "X" pressure The throttle check valve used for setting the supply flow rate of the
exceeds the permissible limit p = 250 bar [3 626 PSI]. pilot oil to the pressure chambers. Simultaneously, the change-
over speed of the main control spool is adjusted. In this way a
smoother change-over, without hydraulic shocks is provided.

Dimensions

Manual override

Hydraulically operated
1. Main valve
4. Throttle / check valve
5.1 4/3 pilot valve
5.2 4/2 pilot valve
10. Control mechanism
11. Pressure reducing valve
14.1 Solenoid "a" MR-045
14.2 Solenoid "b" MR-045
15. Nameplate
16. Fixing screws: 4 pcs M10x60 to
ISO 4762 -10.9
tightening torque Md = 64 Nm
17. Fixing screws: 2 pcs M6x55 to
ISO 4762 -10.9
tightening torque Md = 14 Nm
18. O-ring ports P,A,B,T 22,22 x 2,62
19. O-ring ports X,Y, 10x2
20.1 Plug-in connector "a" grey
20.2 Plug-in connector "b" black
21. Connecting dimmensions to ISO 4401

Electrically operated

Required quality of
the mating surface.

27/01/14 55
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

K V - 4 / 1 6 - - -

Number of control spool positions


Two positions 2
Three positions 3

Manual override option


Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C
Pilot oil supply and discharge
Three positions Two positions

Internal x, y

N
Spool types

1
Internal y, external x
2

3
YN
4

5
Internal x, external y
6

R1
XN
R2

R3
External x, y
R4

R5
Z
R6

R51

For supply and discharge with spool type 2 and 3, refer to the features
F51 table.

51A

51B

56 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

- - - -
*

Mechanically operated
Supply voltage
Direct voltage Alternating voltage
12V 12 DC 12 AC
24V No designation 24 AC
48V 48 DC 48 AC
110V 110 DC 110 AC
230V 230 DC 230 AC*

- Alternating voltage solenoids are fitted with a bridge rectifier.


- With solenoids of over 48 V an earthing clamp ( )
to DIN EN 175301-8003 must be connected.
* To fulfil EMC (89/336/EEC) a capacitor must be built in.

Connector type
EN 175301-803, without signal lamp No designation
EN 175301-803, with signal lamp L

Hydraulically operated
EN 175301-803 without connector K
AMP junior timer without connector M
Deutsch V

Overvoltage
Without overvoltage protection No designation
With overvoltage protection T

Pilot oil control with a double throttle valve


Without a double throttle valve No designation
With a double throttle valve H

Pilot oil control with pressure reducing valve


Without pressure reducing valve No designation
With pressure reducing valve RT

Pre-load valve
Without pre-load valve No designation
With pre-load valve V
Electrically operated

Throttle mm [in]
Without throttle in P line No designation
Throttle Ø 0,8 [0.03 dia] D08
Throttle Ø 1,0 [0.04 dia] D10
Throttle Ø 1,2 [0.05 dia] D12

Seal type
NBR seals for mineral oil HL,HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 57
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

58 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY DIRECTIONAL VALVE KV-3KO (NG 6)

• NG 6
• Up to 250 bar [3 625 PSI]
• Up to 40 L/min [10,6 GPM]

Mechanically operated
• Connection diagram and connecting dimensions to ISO 4401.
• Different types of plug-in connectors.
• 3-chamber model.
• Optimized flow paths for low losses of pressure.
• Wet pin solenoid with interchangeable coil.
• Manual emergency control.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-4/3-3KO-6

Operation Hydraulic symbols

Directional valves type KV-3KO with direct solenoid operation control the direction of the Spool types
hydraulic medium flow.

These directional valves consist of a housing (1), a control spool (3), and one solenoid (2)
with two return springs (4) in 4/2-way directional valves, and two solenoids (2) with two
return springs (4) in 4/3-way directional valves. In 4/3-way directional valves the centre
position of the control spool is the neutral position. The change-over to the operating
position (a) and (b) is done by energizing the solenoids (2) "a" and "b" respectively,
whereby the solenoid plunger acts on the control spool (3) via the operating pin (5), thus
clearing the corresponding flow ways and establishing relevant links between ports A, B, P,
and T.

Hydraulically operated
When the solenoid (2) is de-energized, the control spool (3) is returned to its neutral
position by the return spring (4). The change-over can be done manually by pressing the
emergency manual override (6).

Electrically operated

27/01/14 59
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] see P-Q curves
Ports A, B, P bar [PSI]
Operating pressure 250 [3 625]
PortT bar [PSI]
15 to 380 [69.5 to 1 760]
Viscosity range mm2/s [SUS]

Oil temperature range °C [°F] -20 to +70[-4 to 158]


Filtration NAS 1638 8
Mass 4/2 1,3 [2.9]
kg [lb]
4/3 1,8 [3.9]
Mounting position Optional

Electrical
Direct 12, 24, 48
Supply voltage V
Alternating 110, 230
Power W 26
Switch-on time* ms 50 to 80
Switch-off time* ms 30 to 55
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to50 [122]
Coil temperature °C [°F] to180 [356]
Duty cycle Continuous
* The switching-on and off times apply to 24 V DC solenoids.

P-Q Performance curves P-Q Operating limits


2
Measured at 50°C [122°F] and viscosity of 32 mm /s [148 SUS]. Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].
Diff. pressure

Pressure

Flow
Flow

Flow path
Spool P-A P-B A-T B-T P-T Spool curve
1 1 1 2 2 - 1 1
2 3 3 3 3 5 2 2
3 1 1 4 4 - 3 3
6 1 1 1 1 - 6 4
51A, 51B 1 1 3 3 - 51A, 51B 1
41A, 41B 3 3 - - - 41A, 41B 5

60 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Dimensions

Connection diagram and connecting


dimensions to ISO 4401.

KV-4/2-3KO-6

Mechanically operated
Option: Plug-in connector to ISO 4400 Option: AMP JUNIOR connector

Max. torque 50 Ncm

KV-4/3-3KO-6

Name plate

Hydraulically operated
Max. torque 30 Nm
Max. torque 6 Nm

4 x Fixing screws M5x50 to ISO 4762- 10.9 must be ordered separately.


Required tightening torque Md= 7Nm.

Required quality of the


mating surface.
Electrically operated

Cartridge throttle

If flow rates greater than permissible occur during change-over, a


cartridge throttle must be fitted into P-line of the directional valve.

27/01/14 61
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

K V - / - 3 K O - 6 -

Working ports
Three working ports 3
Four working ports 4

Number of control spool positions


Two positions 2
Three positions 3

Manual override option


Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C

Spool types

1 1A 1B

2 2A 2B

3 3A 3B

6 6A 6B

51A 51B

41A 41B

Port T in the valves with spool type 41A and 41B to be used as lekage line when
working pressure is higher than 210 bar [3 045 PSI].

62 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

-
*

Mechanically operated
Supply voltage
Direct voltage Alternating voltage
12 V 12 DC 12 AC
24 V No designation 24 AC
48 V 48 DC 48 AC
110 V 110 DC 110 AC
230 V 230 DC 230 AC

- Alternating voltage solenoids are fitted with a bridge rectifier.


- With solenoids of over 48 V an earthing clampto ISO 4400 must
be connected

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP junior timer without connector M
Deutsch V

Hydraulically operated
Overvoltage protection
Without overvoltage protection No designation
With overvoltage protection T

Throttle mm [in]
Without throttle in P line No designation
Throttle Ø 0,8 [0.03 dia.] D08
Throttle Ø 1,0 [0.04 dia.] D10
Throttle Ø 1,2 [0.05 dia.] D12

Seal type
NBR seals for mineral oil HL,HLP to
No designation
DIN 51524
FPM seals for HETG, HEES, HEPG to
E
VDMA 24568 and ISO 15380
Electrically operated

Special requirements to be briefly specified

27/01/14 63
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

64 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY DIRECTIONAL PROPORTIONAL VALVE KVP (NG 6)

• NG 6
• Up to 350 bar [5 076 PSI]
• Up to 30 L/min [7.9 GPM]

Mechanically operated
• Plug-in connector for solenoids to ISO 4400.Connection diagram and connection
dimensions to ISO 4401.
• 5 chamber models with good spool guidance.Optional control electronics: Amplifier P/N:
1659574.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KVP-4/3-5KO-6

Operation Hydraulic symbols

The KVP directional control valve is a proportional valve providing variable flow rates. This Spool type
valve is used with control electronics. Typical applications are soft switching via adjustable
ramps for the reduction of hydraulic and mechanical shocks, and electrically adjustable
flow rates - speeds for automating machine functions.

This directional valves consist of a housing (1), a control spool (2), one or two proportional
solenoids (3) and two return springs (4). The change-over can be done manually by
pressing the emergency manual override (5).

Hydraulically operated
Electrically operated

27/01/14 65
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] 10, 20, 30 [2.6 - 5.2 - 7.9]
A, B, P 350 [5 076]
Operating pressure bar [PSI]
T 250 [3 625]
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24to82]
Mounting position Optional
4/2 1,65 [3.63]
Mass kg [lb]
4/3 2,2 [4.85]
Filtration NAS 1638 7

Proportional
Hysteresis 5% of max. flow rate
12 DC 2
Nominal current A
24 DC 1

Electrical
Supply voltage V 12, 24 DC
Power W 36
Ambiant temperature °C [°F] to+50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

Dimensions
Connection diagram and connecting
dimensions to ISO 4401
Max. torque 6 Nm

Max. torque 50 Nm

Fixing screws 4 pcs M5 x 30 to EN ISO 4762 - 10.9 must be


ordered separately / Max. torque Md = 9Nm

Required quality of the


mating surface

66 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Input signal curves / Flow rate Power limits transmitted


2
Measured at 40°C [104°F] and viscosity of 32 mm /s. Measured at 40°C [104°F] and viscosity of 32 mm2/s.
P=5 bar [72.5PSI] P-A or P-B

Mechanically operated
Flow

Flow
% Pp

Model code

K V P - 4 / - 5 K O - 6 -
*
Number of spool positions
Two positions 2

Hydraulically operated
Three positions 3

Special requirements to be
briefly specified
Spool types

1A

1B

Seal type
6A
NBR seals for mineral oil HL, HLP, to
No designation
DIN 51524
6B FPM seals for HETG, HEES, HEPG
E
to VDMA 24568 and ISO 15380
Electrically operated

Connector type
No designation EN 175301-803 without signal lamp
Regulated flow rate
(P=5 bar [72.1 PSI] / P-A or P-B) L EN 175301-803 with signal lamp
0-10 L/min [0-2.6 GPM] 10 K EN 175301-803 without connector
0-20 L/min [0-5.2 GPM] 20 V Deutsch
0-30 L/min [0-7,9 GPM] 30

Supply voltage
Direct voltage 24V No designation
Direct voltage 12V 12 DC

27/01/14 67
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

68 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY BANKABLE DIRECTIONAL VALVES KVM (NG 6)

• NG 6
• Up to 350 bar [5 076PSI]

Mechanically operated
• Up to 40 L/min [10.6 GPM]

• Threaded connection to ISO 9974 (Metric), ISO1179 (BSPP/Gas).


• Series or parallel connections.
• Inlet plate possbility with pressure relief valve, pump unloading valve or flow control valve.
• Possibility to use standard components for vertical stacking.

KVM-6-...-VV-KV-N4

Basic concept

Hydraulically operated
1. Basic (directional control) valves KVM-6 5. Threaded connection P
2. Inlet plate OB-KVM-6 6. Threaded connection T
3. End plate ZB-KVM-6 7. Threaded connection A
4. Fixing elements for mounting SET-KVM-6 8. Threaded connection B
9. Threaded connection MP (closed)

Type of connection
Electrically operated

Parallel (KVM-P) Series (KVM-S)

27/01/14 69
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

70 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

4/2, 4/3 WAY BANKABLE DIRECTIONAL VALVES KVM (NG 6)

• NG 6
• Up to 350 bar [5 076 PSI]
• Up to 40 L/min [10.6 GPM]

Mechanically operated
• Parallel or series connection.
• Plug-in connection for solenoids to ISO 4400.
• 5-chamber model with good spool guidance.
• Wet pin solenoid with interchangeable coil.
• Manual emergency control.
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).
• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).

KVM-P-4/3-6-1-1-12DC-3/8

Hydraulic symbol

Spool types - Parallel connection (KVM-P)

Spool types - Series connection (KVM-S)

Hydraulically operated
Features

Hydraulic
KVM-P KVM-S
Size 6 6

Flow rate L/min [GPM] 40 [10.6] 30 [7.9]

A, B, P 350 [4 568] 250 [3 626]


Operating pressure bar [PSI]
T 250 [3 626]
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
1,85 [4.08]
Mass 4/2 kg [lb]
4/3 2,4 [5.29]
Electrically operated

Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
29
Power W
(12 V DC supply voltage) 36
Switching frequency 1/h 15 000
Ambiant temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

27/01/14 71
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

(Manual override - G)

(Manual override - G)

1. Solenoid ’’a’’ / MR-045-O


2. Solenoid ’’b’’ / MR-045-O
3. Plug-in connector «a» -grey
4. Plug-in connector «b» -black
5. Emergency manual override
6. Manual override with rubber (G)
7. O-ring 9,25 x 1,78
8. Valve cap (KVM-...-4/2)
9. Nameplate
10. Threaded connection A-M torque = max. 100 Nm
11. Threaded connection B-M torque = max. 100 Nm

Connection dimensions for KVM-6

Required quality of the mating surface

72 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Parallel connection -KVM-P (N1 to N8) .Series connection -KVM-S (P to T).

Mechanically operated
Diff. pressure
Diff. pressure

Flow Flow

Series connection -KVM-S (P to A(B)).

Hydraulically operated
Diff. ressure

Flow

The operating limits of the valve shall be determined at a voltage 10% bellow
the nominal rating. The curves refer to application with symmetrical flow
throw the valve (P-A and B-T). In the case of asymmetrical flow (e.g. one part
not used) reduced values may result.
Pressure

Spool type Curve


Electrically operated

1 1
2 2
3,6 3

Flow

27/01/14 73
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

K V M - - 4 / - 6 -

Type of connection
Series connection S
Parallel connection P

Number of control spool positions


Two positions 2
Three positions 3

Manual override option


Emergency manual override No designation
Manual override with rubber G
Lockable manual override C

Spool type

1A

3A

6A
Parallel connection
(KVM-P)
51A

1B

3B

6B

51B

81

Series connection
2A
(KVM-S)

2B

74 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

- - -
*

Mechanically operated
Supply voltage
Direct voltage 24V No designation
Direct voltage 12V 12 DC

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP Junior timer without connector M
Deutsch V

Overvoltage protection
Without overvoltage protection No designation

Hydraulically operated
With overvoltage protection T

Threaded connections
M18 x1,5 No designation
G3/8 3/8
9/16-18 UNF-2B SAE 6

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA 24568 and ISO 15380 E Electrically operated

Special requirements to be briefly specified

27/01/14 75
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

76 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

VERTICAL STACKING FOR KVM VALVES

• NG 6

Mechanically operated
• Up to 350 bar [5076 PSI]
• Up to 40 l/min [10.56 GPM]

• Threaded connections to ISO 9974, ISO 1179 or ISO 11926.


• Possibility of stacking one, two or three vertical stacking components.

Mounting example Hydraulic symbol

B
1. Bankable directional valve KVM-6
2. First stacking component (KVM-NOV-6) A
3. Second stacking component (KVM-NDV-6)
4. Third stacking component (KVM-VV-6)
5. Mounting screws for vertical stacking components:
• M5x55, ISO 4762-10.9 (for one stacking component) - ordering code: 1114573
• M5x95, ISO 4762-10.9 (for two stacking components) - ordering code: 1253603
• M5x135, ISO 4762-10.9 (for three stacking components) - ordering code: 1668356

Mounting screws tightening torque: max. 9 Nm [79.6 in.lbf]

Hydraulically operated
45 [1.77]

4
45 [1.77]

2
45 [1.77]

1
a
a

55 [2.16]
P

23
0

5
Electrically operated

[0.90]
B
T
b
47 [1.85]

[0.92]
23,5

Threaded connections options:


• M16x1,5 (ISO 9974-1)
• G3/8 (ISO 1179-1)
• 9/16-18 UNF-2B (ISO 11926-1)

27/01/14 77
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Directional valve KVM and KVM-VV-6 relief valve mounting example Hydraulic symbol

A B
4
45 [1.77]

a
55 [2.16]

a
A
P
23
5

0
[0.90]

B
T
47 [1.85]

b
[0.92]
23,5

b
Threaded connections

Directional valve KVM and KVM-NDV-6 throttle valve mounting example Hydraulic symbol

A B
3
45 [1.77]

1
a
P

55 [2.16]
0

23 5
B
T

[0.90]
b
47 [1.85]
[0.92]
23,5

Threaded connections

78 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Solenoid orientation options Sealing between stacking elements

Six different orientation options:

30° 30°

Mechanically operated
[dia. 0.07]
1,78
17,2
[dia. 0.68]

30° 30°

Hydraulically operated
Electrically operated

27/01/14 79
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

80 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

CHECK VALVE KVM-NOV-6

• Up to 350 bar [5 076 PSI]

Mechanically operated
• Up to 40 l/min [10,6 GPM]

• Flow shut-off in both or one service line.


• For vertical stacking on KVM directional valves.

Operation Hydraulic symbols


A B
Pilot operated check valves type KVM-NOV-6 enables the hydraulic fluid flow in the service
lines to be automatically shut off and made free, respectively.
Free flow direction is always from the valve side to the ports side. In the opposite direction KVM-NOV-6-D
is the valve blocked for the hydraulic fluid flow. Free flow in port A in direction from ports to
valve side is achieved by means of pressure in port B and vice versa.
To assure zero leakage there is necessary to discharge ports A and B towards port T in the
zero position of the directional valve. A B

KVM-NOV-6-EA

Hydraulically operated
A B

KVM-NOV-6-EB

Features Mounting example

Size 6
Flow rate l/min [GPM] 40 [10.5]
Operating pressure bar [PSI] 350 [5 076]
Cracking pressure bar [PSI] 1 [14.5] A B
Area ratio 1:3,9
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1760]
Filtration ISO 4406: 1999 19/17/14
Mass kg [lbs] 1,4 [3.0]
a

Electrically operated
a
P

A
0

B
T
b
b

27/01/2014 81
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

45 [1.77]
116 [4.57] 45 [1.77]

40,5 [1.59]
0,75 [0.03]

37,5 [1.48] Threaded


5,5 [0.22] connections
[0.61]
15,5

0.01

Rmax 8
31 [1.22]

[1.28]
32,5
P-Q Performance curves
Measured at 50C [122F]
and viscosity of 32 mm2/s [148 SUS].
bar [PSI]
10 145

8 116
Diff. pressure

6 87

4 58 Against spring force


Pilot opened
2 29

0 0
0 5 10 15 20 25 30 35 40 l/min
[0] [1.32] [2.64] [3.96] [5.28] [6.60] [7.93] [9.25] [10.57] [GPM]
Flow

Model code

K V M - N O V - 6 - - - -
*
Symbol
A B Threaded connections Special requirements
to be briefly specified
M16 x 1,5 (ISO 9974-1) No designation
D G3/8 (ISO 1179-1) 3/8
9/16-18 UNF-2B (ISO 11926-1) SAE6
A B

EA
Seal type
NBR seals for mineral oil HL,HLP to DIN 51524 No designation
A B
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380
D

82 27/01/2014
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

THROTTLE WITH CHECK VALVE KVM-NDV-6

• Up to 350 bar [5 076 PSI]

Mechanically operated
• Up to 40 l/min [10.6 GPM]

• Flow control in both or one service line.


• For flow throttling in supply and/or return lines.
• For vertical stacking on KVM directional valves.

Operation Hydraulic symbols

Throttle with check valves type KVM-NDV-6 are used for throttling flow of the A B A B

hydraulic fluid in lines A and/or B. The KVM-NDV-6 valves are allowing free flow
in one direction through check valve and throttled flow in reversed direction. D0 D1
Hydraulic fluid flow is throttled depending od adjustment of the throttling screw.

A B A B

A0 A1

Hydraulically operated
A B A B

B0 B1

Features Mounting example

Size 6
Flow rate l/min [GPM] 40 [10.6]
Operating pressure bar [PSI] 350 [5 076]
Cracking pressure bar [PSI] 0,5 [7.2]
A B
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1760]
Filtration ISO 4406: 1999 19/17/14
Mass kg [lbs] 1,5 [3.3]
Electrically operated
a
a
P

A
0

B
T
b
b

27/01/2014 83
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

SW13

45 [1.77]
100 [3.94] 45 [1.77]
141 [5.55] throttles closed
160 [6.30] throttles opened
SW5
40,5 [1.59] Throttling screw*
0,75 [0.03]

37,5 [1.48] Threaded


5,5 [0.22] connections
[0.61]
15,5

0.01
31 [1.22]

Rmax 8

[1.28]
32,5
* Clockwise rotation reduces the hydraulic fluid flow.It is recommended that the valve is set at zero pressure in setting line.

P-Q Performance curve

Measured at 50C [122F]


and viscosity of 32 mm2/s [148 SUS].

bar [PSI]
20 290
18 261
16 232
14 203
Diff. pressure

12 174
10 145 Through check
valve
8 116
6 87
4 58
2 29
0 0
0 5 10 15 20 25 30 35 40 l/min
[0] [1.32] [2.64] [3.96] [5.28] [6.60] [7.93] [9.25] [10.57] [GPM]

Flow

84 27/01/2014
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Model code

K V M - N D V - 6 - - - -
*

Mechanically operated
Symbol
A B Threaded connections Special requirements
to be briefly specified
M16 x 1,5 (ISO 9974-1) No designation
D0 G3/8 (ISO 1179-1) 3/8
9/16-18 UNF-2B (ISO 11926-1) SAE6

A B

A0
Seal type
NBR seals for mineral oil HL,HLP to DIN 51524 No designation
A B FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380
B0

A B

D1

Hydraulically operated
A B

A1

A B

B1

Electrically operated

27/01/2014 85
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

86 27/01/2014
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

PRESSURE RELIEF VALVE KVM-VV-6

• Up to 350 bar [5 076 PSI]


• Up to 40 l/min [10.6 GPM]

Mechanically operated
• Direct operated.
• For vertical stacking on KVM directional valves.
• Multiple pressure setting ranges.
• Various hydraulic symbols.

Operation

Throttle with check valves type KVM-NDV-6 are used for throttling flow of the hydraulic fluid in lines A and/or B. The KVM-NDV-6 valves
are allowing free flow in one direction through check valve and throttled flow in reversed direction. Hydraulic fluid flow is throttled
depending od adjustment of the throttling screw.

Hydraulic symbols
KVM-VV-6-AB KVM-VV-6-BA KVM-VV-6-AT

A B A B A B

Hydraulically operated
T

KVM-VV-6-DT KVM-VV-6-DD

A B A B

KVM-VV-6-BT

A B

T T

Features

Size 6
Electrically operated

Flow rate l/min [GPM] 40 [10.6]


Pressure setting range bar [PSI] 15 - 350 [270 - 5 076]
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1760]
Filtration ISO 4406: 1999 19/17/14
Mass kg [lbs] 1,1 - 1,8 [2.4 - 4.0]

27/01/2014 87
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

SW19

45 [1.77]
L3 L2 45 [1.77]
L1

SW5
Adjusting screw*
40,5 [1.59]
37,5 [1.48]
0,75 [0.03]

5,5 [0.22] Threaded


L5 connections
[0.61]
15,5

Mating surface quality


0.01
31 [1.22]

[1.28]
32,5
Rmax 8

* Clockwise rotation increases pressure rise at the inlet port of pressure relief valve.

L1 L2 L3 L4 L5 Mass
Option
mm [inch] mm [inch] mm [inch] mm [inch] mm [inch] kg [lbs]
KVM-VV-6-AB 109 [4.29] 70 [2.76] 0 39 [1.53] 13,5 [0.53] 1,1 [2.42]
KVM-VV-6-BA 109 [4.29] 70 [2.76] 39 [1.53] 0 13,5 [0.53] 1,1 [2.42]
KVM-VV-6-AT 144 [5.67] 100 [3.94] 44 [1.73] 0 29 [1.14] 1,6 [3.53]
KVM-VV-6-BT 121,5 [4.78] 80 [3.15] 0 41,5 [1.63] 8,5 [0.33] 1,3 [2.87]
KVM-VV-6-DT 188 [7.40] 100 [3.94] 44 [1.73] 44 [1.73] 28,5 [1.12] 1,8 [3.97]
KVM-VV-6-DD 188 [7.40] 100 [3.94] 44 [1.73] 44 [1.73] 28,5 [1.12] 1,8 [3.97]

P-Q Performance curves


Measured at 50C [122F]
and viscosity of 32 mm2/s [148 SUS].
bar [PSI]
400 5802

350
360 5221

320 4641

280 4061

240 3481
Diff. pressure

200
200 2901

160 2321
120
120 1740

80 1160
50

40 580

0 0

0 5 10 15 20 25 30 35 40 l/min
[0] [1.32] [2.64] [3.96] [5.28] [6.60] [7.93] [9.25] [10.57] [GPM]
Flow

88 27/01/2014
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Model code

K V M - V V - 6 - - - -
*

Mechanically operated
Symbol
A B
Special requirements
to be briefly specified
D0
Threaded connections
M16 x 1,5 (ISO 9974-1) No designation

A B
G3/8 (ISO 1179-1) 3/8
9/16-18 UNF-2B (ISO 11926-1) SAE6
A0

A B

B0
Pressure setting range
T bar [PSI]
A B
15 - 50 [217 - 725] 50
51 - 120 [740 - 1740] 120
D1 121 - 200 [1755 - 2900] 200
201 - 350 [2915 - 5076] 350
T

Hydraulically operated
A B

A1

A B

B1

Electrically operated

27/01/2014 89
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

90 27/01/2014
VERTICAL STACKING ON VALVES KVM
WITH STANDARD SANDWICH VALVES TO ISO 4401 (NG 6)

POCLAIN HYDRAULICS Hydraulic components - Directional control valves

VERTICAL STACKING ON VALVES KVM WITH STANDARD


SANDWICH VALVES TO ISO 4401 (NG 6)

Mechanically operated
• NG 6
• Up to 350 bar [5076 PSI]
• Up to 40l/min [10.57 GPM]

• Use standard components for vertical stacking.


• Threaded connections to ISO 9974 or ISO 1179.
• Possibility of stacking one or two standard components.

KVM-P-4/3-5KO-6 and VP-NOV-6 for stacking

Description Hydraulic symbol


One standard component
1. Bankable directional valve KVM-6
2. STACK-KVM-6 consist of: VP-NOV-6 VP-NDV-6
2.1 Adapter plate and two O-rings 18,77 x 1,78
2.2 End plate and two O-rings 9,25 x 1,78
2.3Fixing screws M5x100 ISO 4762-10.9 (for one stacking component)
or M5x140 ISO 4762-10.9 (for two stacking components)
3. First stacking component (standard VP-NOV-6 or VP-NDV-6)
4. Second stacking component (standard VP-NDV-6)

Hydraulically operated
(Two components)

Two standard components

Electrically operated

Mtorque = max. 9Nm [79.6 in.lbf]

27/01/14 91
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

S T A C K - K V M - 6 - - - -
*
Number of stacking components
One standard component N1
Two standard components N2

Threaded connections
G3/8 (ISO 1179) 3/8
M18 x 1,5 (ISO 9974) No designation

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA 24568
E
and ISO 15380

Special requirements to be briefly specified

92 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

AUXILIARY CONTROL LEVER

Mechanically operated
• Compatible with KV-5KO-6, KVM-6 and KVP-5KO-6 directional valves
• Without impact on valve´s performance.
• Up to 250 bar [3 625 PSI] on T port.

Description Hydraulic symbols

The optional auxiliary control lever module offers solenoid or manual operation of a\0/b
A B
directional valves. Control lever provides mechanical connection with main control
spool without significant impact on valve's performance. Auxiliary control lever a 0 b
module is mounted between the valve housing and solenoid. During solenoid
operation, hand lever remains in neutral position. Modular and robust design of a P T b
auxiliary control lever enables installation on A or B side of various types of
directional valves and operating pressure range up to 250 bar [3 625 PSI] on T port. a\0/b
A B

a 0 b
a P T b

Hydraulically operated
Features

Size 6
Ports A, B, P bar [PSI] 350 [5 076]
Operating pressure
Port T bar [PSI] 250 [3 626]
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [69.5 to 1760]
Filtration ISO 4406: 1999 19/17/14
Lever actuating force (end stroke) N [lbf] 40 [9.0]
Mass (ACL module) kg [lbs] 0,9 [1.98]

Dimensions
12° 12°
Electrically operated
83 [3.27]

139 [5.47]

73 [2.87] 78 [3.07] 56 [2.20] 46 [1.81]


280 [11.02] 52 [2.05]

27/01/2014 93
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Model code

The auxiliary control lever on valves KV-5KO-6 and KVM-6 is defined by the designation in the manual override option field.

K V - 4 / 3 - 5 K O - 6 - - ...

K V M - P or S - 4 / 3 - 6 - - ...

Manual override option


Emergency manual override No designation
Manual override with rubber G
Lockable manual override C
Auxiliary control lever on valve side A FA
Auxiliary control lever on valve side B FB

The auxiliary control lever on valves KVP-6 is defined by the designation FA or FB in the special requirements field.

94 27/01/2014
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

INLET PLATE OB-KVM-6 (NG 6)

• NG 6
• Up to 350 Bar [5076 PSI]
• Up to 40 L/min [10,6 GPM]

Mechanically operated
• Provide pressure relief valve.
• Provide pump unloading valve.
• Provide flow control valve.
• Threaded connections to ISO 9974 (Metric),
ISO 1179 (BSPP/Gas), ISO 11926 (UNF).

OB-KVM-6-VV20-KVO OB-KVM-6-VV20-TVTPG

Hydraulic symbol

OB-KVM-6 OB-KVM-6-VV20-KV1

Hydraulically operated
OB-KVM-6-VV35 OB-KVM-6-VV20-TVTP

By-pass way

Features

OB-KVM-6 OB-KVM-6-VV OB-KVM-VV-KV OB-KVM-VV-TVTP


Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Electrically operated

Filtration NAS 1638 8


Mass kg [lbs] 1,25 [2.76] 1,35 [2.98] 2,2 [4.85] 4,5 [9.92]
Flow rate l/min [GPM] / 40 [10.6]
/ 50-210 [13-55]
Press Setting bar [PSI]
/ 100-350 [26-92]
Adjustments / allen key
Max. pressure bar [PSI] / / 350 [5 076] 210 [3 045]
Supply voltage V DC / / 12, 24 /
Power W / / 17 /
Flow - inlet l/min [GPM] / / / max. 50 [max. 13,21]
Flow - priority way l/min [GPM] / / / 0 - 25 [0 - 6.6]
Flow - bypass l/min [GPM] / / / max. 40 [max. 10,6]

27/01/14 95
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

OB-KVM-6 OB-KVM-6-VV...-KV...
OB-KVM-6-VV

1. Pressure relief valve


2. Pump unloading valve
3. Manual override with knob
4. Threaded connection MP - G1/4 (closed)
6. Connection dimensions for KVM-6
7. Fixing hole (M8 X 12) for mounting assembly

96 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Dimensions

OB-KVM-6-VV...-TVTP...

Mechanically operated
Hydraulically operated
KVM-6-Ventile - Bypass-Strom

Electrically operated

KVM-6-Ventile - Hauptstrom
1. Pressure relief valve
2. Flow control valve - rotary knob -TVTPB
3. Flow control valve - proportional solenoid - TVTP
4. Flow control valve - proportional solenoid with manual
override - TVTPG
5. Threaded connection MP - G1/4 (closed)
6. Nameplate
7. Bankable directional valves KVM-6 Priority flow
8. Bankable directional valves KVM-6 Bypass flow
9. Fixing hole (M8 x 12) for mounting assembly
10. Connection dimensions for KVM-6 (see page 12.11.3)

27/01/14 97
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 28 mm2/s [148 SUS].


.OB-KVM-6-VV (pressure relief valve- flow P to T. OB-KVM-6-KV (pump unloading valve- flow P to T.
Pressure drop

Pressure drop

Flow Flow

98 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Model code

O B - K V M - 6 - - - - - - -
*

Mechanically operated
Pressure relief valve
Without pressure relief valve No designation
Pressure relief valve range 50-210 bar
VV20
[725-3045 PSI]
Pressure relief valve range 100-350 bar
VV35
[1450-5076 PSI]

Pump unloading valve


No
Without pump unloading valve designation
Pump unloading valve - normally closed KV0
Pump unloading valve - with manual override - knob KVG0
Pump unloading valve - normally open KV1
Pump unloading valve - with manual override - knob KVG1

Normally open Normally closed

Hydraulically operated
Flow control valve
Without flow control valve No designation
Flow control valve - rotary knob - TVTP-25-B TVTPB
Flow control valve - prop. solenoid - TVTP-25-P TVTP
Flow control valve - with manual override - knob TVTPG

supply voltage
Direct voltage 24 V No designation
Direct voltage 12 V 12

Threaded connections
M18 x 1,5 (ISO 9974) No designation
M22 x 1,5 (ISO 9974) M22
G1/2 (ISO 1179) 1/2
G3/8 (ISO 1179) 3/8
3/4-16 UNF-2B SAE 8
Electrically operated

Plug-in connector
Without signal lamp No designation
With signal lamp L

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA 24568
E
and ISO 15380

Special requirements to be briefly specified

27/01/14 99
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

100 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

END PLATE ZB-KVM-6


Dimensions
Fixing hole M8 x 12 for mounting
assembly

Mechanically operated
Threaded connection
(reserve port T)

ZB-KVM-6

* ZB-KVM-6-PT-1/2(M22) = 27 Mass = 0,8 kg

Hydraulically operated
Model code

Z B - K V M - 6 - - - -
*
Symbol

No designation

PT

((It is necessary to use this end plate by series


connections KVM-S)(

Threaded connections
M18 x 1,5 (ISO 9974) No designation
Electrically operated

M22 x 1,5 (ISO 9974) M22


G1/2 (ISO 1179) 1/2
G3/8 (ISO 1179) 3/8
3/4-16 UNF-2B 3/4-16UNF

Seal type
NBR seals for mineral oil HL, HLP to DIN
No designation
51524
FPM seals for HETG, HEES, HEPG to
E
VDMA 24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 101
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

102 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

FIXING ELEMENTS FOR MOUNTING

• SET-KVM-6 consists of:

Mechanically operated
a) Nuts: 3 x M8 DIN 1587
b) Washers: 3 x A8 DIN 6798-J
c) Screws: 3 x M8 DIN 939 10.9

SET-KVM-6-N3

Description Model code

Screw M8 DIN 939 10.9:


S E T - K V M - 6 -

Number of bankable directional


valves KVM-6
L mm [in] :Max. number of bankable One valves KVM-6 N1
80 [3,15]

Hydraulically operated
N1 valves KVM: Two valves KVM-6 N2
N2 127 [4,99] Three valves KVM-6 N3
N3 174 [6,85] a) parallel connection (KVM-P) = Four valves KVM-6 N4
eight valves (max. N8).
N4 221[8,70] Five valves KVM-6 N5
N5 268 [10,55] Six valves KVM-6 N6
N6 315 [12,40] Seven valves KVM-6 N7
N7 362 [14,25] Eight valves KVM-6 N8
N8 409 [16,10]

Electrically operated

27/01/14 103
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

OB-KVM-6, OB-KVM-6-VV

H1 H2
OB-KVM-6 or OB-KVM-6-VV... 75+Nx47 (N = 1 to 8) 39+Nx47 (N = 1 to 8)
OB-KVM-6-VV...-KV... 90+Nx47 (N = 1 to 8) 54+Nx47 (N = 1 to 8)

OB-KVM-6-VV...-TVTPB...

1. [141 in.lbf]Mtorque / Parallel connection (KVM-P) - max. 20Nm [177 in.lbf] / Series connection (KVM-S) - max. 16 Nm

104 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

• NG 6
• Up to 350 bar [5 076 PSI]

Mechanically operated
• Up to 50 L/min [13.2 GPM]

• Plug-in connector for solenoids to ISO 4400.


• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-6/2-6-S50

Operation Hydraulic symbol

Directional valves type KV with direct solenoid operation control the direction of the Spool type
hydraulic medium flow. They are mostly used as link between two consumers and the
basic directional valve, when we want to control both consumers alternately by means of
one basic directional valve.

The KV type directional valves consist of a housing (1), a control spool (2), a solenoid (3)
and a return spring (5).

Change-over to the operating position is done by energizing the solenoid (3), whereby the
solenoid plunger acts on the control spool (2) via the operating pin (4), thus clearing the
corresponding flow ways and establishing respective links between the ports
P1, A, B and P2.

Hydraulically operated
Mounting example
When the solenoid (3) is de-energized, the control spool (2) is returned to its neutral
position by the return spring (5), thus establishing again the links between ports P1, C, D
and P2.

The change-over can also be done manually by pressing the emergency manual override
(6).

Electrically operated

27/01/14 105
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] 50 [13.2]
With YZ 350 [5 076]
Operating pressure bar [PSI]
Without YZ 250 [3 625]
Oil temperature range °C [°F] -20 to +70 [-4 to+158]

Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]

Mounting position Optional


Mass kg [lb] 2,5 [5.51]
Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
Power W 29 *
Switching frequency 1/h 15 000
Ambiant temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous
* 12 V supply voltage - 36 W.

Dimensions

Max. torque 6 Nm

Threaded connections M

Threaded connections YZ

3. Solenoid ’’a’’ MR-045


6. Emergency manual override
7. Plug in connector «a» grey
8. Nameplate
9. Valve cap

With hand operation

106 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

p-Q Performance curve


Measured at 40°C [104°F] and viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Diff. pressure

Flow

Model code

K V - 6 / 2 - 6 - - - - - - - - S 5 0 -
*
Spool type

No designation

Hydraulically operated
AB Special requirements to
be briefly specified

Overlap
Seal type
No designation
NBR seals for mineral oil HL,
No designation
HLP to DIN 51524
FPM seals for HETG, HEES,
P E HEPG to VDMA 24568 and
ISO 15380

Manual override option


Emergency manual override No designation
Drainage
Manual override with rubber cover G
No designation Without YZ
Lockable manual override C
YZ With YZ

Supply voltage
Electrically operated

Direct voltage 24V No designation


Direct voltage 12V 12 DC
Threaded connections M ; YZ
Connector type No designation M18x1,5 ; M14x1,5
EN 175301-803 without signal lamp No designation M22 M22x1,5 ; M14x1,5)
EN 175301-803 with signal lamp L 3/8 G3/8 ; G1/4)
EN 175301-803 without connector K 1/2 G1/2 ; G1/4)
AMP Junior timer without connector M SAE 8 3/4-16 UNF-2B; 9/16-18 UNF-2B
Deutsch V

Overvoltage protection
Without protection No designation
With protection T

27/01/14 107
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

108 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVES KV (NG 10)

• NG 10
• Up to 350 bar [5 076 PSI]

Mechanically operated
• Up to 120 L/min [31.7 GPM]

• Plug-in connector for solenoids to ISO 4400.


• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP65 to EN 50529 / IEC 60529.

KV-6/2-10

Operation Hydraulic symbol

Directional valves type KV with direct solenoid operation control the direction of the
hydraulic medium flow. They are mostly used as link between two consumers and the
basic directional valve, when we want to control both consumers alternately by means of
one basic directional valve.

The KV type directional valves consist of a housing (1), a control spool (2), a solenoid (3)
and a return spring (5).

Change-over to the operating position is done by energizing the solenoid (3), whereby the
solenoid plunger acts on the control spool (2) via the operating pin (4), thus clearing the
corresponding flow ways and establishing respective links between the ports
P1, A,B and P2.

Hydraulically operated
When the solenoid (3) is de-energized, the control spool (2) is returned to its neutral
position by the return spring (5), thus establishing again the links between ports P1, C,D Mounting example
and P2.

The change-over can also be done manually by pressing the emergency manual override
(6).

A
P1 P2

6 3 4 1 2 5

A B
Electrically operated

A B

P1 P2

C D L

C D L

27/01/14 109
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 10
Flow rate L/min [GPM] 120 [31.7]
With YZ 350 [5 076]
Operating pressure bar [PSI]
Without YZ 250 [3 625]
Oil temperature range °C [°F] -20 to+70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Mounting position Optional
Mass kg [lb] 5,5 [12.12]
Filtration NAS 1638 8

Electrica
Supply voltage V 12, 24 DC
Power W 45
Switching frequency 1/h 15000
Ambient temperature °C [°F] to+50 [to +122]
Coil temperature °C [°F] to+180 [to +356]
Duty cycle Continuous

Dimensions
[0.6]

[4.8] )(with manual override)

[4.5]

Threaded connection YZ
[1.10] [1.81] YZ
[4]

[2.69]
[1.25]

108 [4.25] [5.11]

246 [9.68]

[2.2] [1.81] Threaded connections M


[1.33] [1.81]

3. Solenoid ’’a’’ MR-060


6. Emergency manual override
[2.87]

7. Plug-in connector «a» - grey


[1.97]

8. Nameplate
9. Valve cap
[1.43]

[0.45]

Max. torque = 6Nm


[1.24] [2.63]

110 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Diff. pressure

Flow

Model code

K V - 6 / 2 - 10 - - - - - -
*
Manual override option
Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C

Hydraulically operated
Supply voltage
Direct voltage 24V No designation
Direct voltage 12V 12 DC

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP Junior timer without connector M
Deutsch V

Overvoltage
Without overvoltage protection No designation
With overvoltage protection T

Threaded connections M ; YZ
M22x1,5; M14x1,5 M22
M27x2; M14x1,5 M27
G1/2; G1/4 1/2
G3/4; G1/4 3/4
Electrically operated

7/8-14 UNF-2B; 9/16-18 UNF-2B SAE 10


Drainage
Without YZ No designation
With YZ YZ

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 111
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

112 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVES KV (NG 16)

• NG 16
• Up to 350 bar [5 076 PSI]
• Up to 250 L/min [66.04 GPM]

Mechanically operated
• Plug-in connector for solenoids to ISO 4400.
• Threaded connections to ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Flange ports to ISO 6162-2.
• Fulfil EMC (89 / 336 / EEC).
• Protection of solenoid IP 65 to EN 60529 / IEC 60529.

KV-6/2-16-XN

Hydraulic symbol

KV-6/2-16-...-XN KV-6/2-16-...-N KV-6/2-16-...-Z

Hydraulically operated
Features

Hydraulic
Size 16
Flow rate L/min [GPM] 250 [66]
bar [PSI] 15 to 350 [217.56 to 5076.32]
Operating pressure
(in port L or in return way) bar [PSI] 250 [3625.94]
Oil temperature range °C [°F] -20 to +70[-4 to 158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Mounting position Optional
Mass kg [lb] 22 [48.50]
Electrically operated

Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
W 29
Power
(12 V DC supply voltage) 36
Switching frequency 1/h 15 000
Ambiant temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

27/01/14 113
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

KV-6/2-16-...-G1/G1/4 Threaded connections M


A, B, C, D, P1, P2

1. Emergency manual override


2. Solenoid ’’a’’ MR-045
3. Plug-in connector «a» - grey
4. Nameplate

Threaded connections L
G1/4

KV-6/2-16-...-SAE...

Size
SAE 3/4 SAE 1
a 50.8 [2] 57.2[2.25]
23.8 [0.94]
b 27.8 [1.09]
M1 M10 M12

SAE-flange connection - High pressure serie

Threaded connections L

1. Emergency manual override


2. Solenoid ’’a’’ MR-045
3. Plug-in connector «a» - grey
4. Nameplate

114 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Pressure drop

Flow

Model code

K V - 6 / 2 - 16 - - - - - -
*
Pilot oil supply and discharge
Internal x, y N
Internal, external y (port L) XN
external, external Z

Hydraulically operated
Threaded connections M ; L
G1 ; G1/4 G1/G1/4
1 5/16-12 UNF-2B ; 9/16-18 UNF-2B SAE 16
SAE-Flange connections 3/4 - high pressure series SAE3/4
SAE-Flange connections 1 - high pressure series SAE1

Manual override option


Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C

supply voltage
direct voltage 24 V No designation
direct voltage 12 V 12 DC

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
G1/2 (YZ=G1/4) without connector K
AMP junior timer without connector M
Electrically operated

Deutsch V

Overvoltage protection
without overvoltage protection No designation
with overvoltage protection T

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 115
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

116 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVES KV-6K (NG 6)

• NG 6
• Up to 250 bar [3 625 PSI]
• Up to 50 L/min [13.2 GPM]

Mechanically operated
• Direct in-line mounting.
• Plug-in connector for solenoids to ISO 4400.
• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP65 to EN 60529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-6K/2-6

Operation Hydraulic symbol

Directional valves type KV-6K/2-6 with direct solenoid operation control the direction of the Spool type
hydraulic medium flow.
They are mostly used as link between two consumers and the basic directional valve,
when we want to control both consumers alternately by means of one basic directional
valve.

The KV-6K/2-6 type directional valves consist of a housing (1), a control spool (2), and a
solenoid (3) with return spring (5).

Change-over to the operating position is done by energizing the solenoid (3), whereby the
solenoid plunger acts on the control spool (2) via the operating pin (4), thus clearing the
corresponding flow ways and establishing respective links between the ports

Hydraulically operated
P1, A,B and P2.
Mounting example
When the solenoid (3) is de-energized, the control spool (2) is returned to its neutral
position by the return spring (5), thus establishing again the links between ports
P1, C,D and P2.

The change-over can also be done manually by pressing the emergency manual override
(6).

Electrically operated

27/01/14 117
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] 50 [13.2]
Operating pressure bar [PSI] 250 [3 625]
Oil temperature range °C [°F] -20 to +70 [-4 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3,24 to 82]
Mounting position Optional
Mass kg [lb] 2,5 [5.51]
Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
Power W 29
(12 V DC supply voltage) W 36
Switching frequency 1/h 15000
Ambient temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

Dimensions

Threaded connection

3. Solenoid ’’b’’ MR-045


6. Emergency manual override
7. Plug in connector «b» black
8. Nameplate
9. Valve cap

118 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Pressure drop

Flow

Model code

K V - 6 K / 2 - 6 - - - - -
*
Manual override option
Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C

Hydraulically operated
Special requirements to be
Supply voltage briefly specified
Direct voltage 24V No designation
VDirect voltage 12V 12 DC

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP Junior timer without connector M
Deutsch V

Overvoltage
Without overvoltage protection No designation
With overvoltage protection T
Electrically operated

Threaded connections
M18x1,5 No designation
G 3/8 G3/8
9/16-18 UNF-2B SAE 6

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA 24568 and
E
ISO 15380

27/01/14 119
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

120 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVES KVH (NG 6)

• NG 6
• Up to 315 bar [4 568 PSI]
• Up to 50 L/min [13.2 GPM]

Mechanically operated
• Plug-in connector for solenoids to ISO 4400.
• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP65 to EN 50529 / IEC 60529.
• Fulfil EMC (89/336/EEC).
• For stacking (1-5 units).

KVH-6/2-6-S50-N3

Operation Hydraulic symbol

Directional valves type KVH with direct solenoid operation control the direction of the
hydraulic medium flow.
They are mostly used as link between two consumers and the basic directional valve,
when we want to control both consumers alternately by means of one basic directional
valve.

The KVH type directional valves consist of a housing (1), a control spool (2), and a
solenoid (3) with return spring (5).

Change-over to the operating position is done by energizing the solenoid (3), whereby the Mounting example
solenoid plunger acts on the control spool (2) via the operating pin (4), thus clearing the
corresponding flow ways and establishing respective links between the ports

Hydraulically operated
P1, A, B and P2.

When the solenoid (3) is de-energized, the control spool (2) is returned to its neutral
position by the return spring (5), thus establishing again the links between ports
P1, C, D and P2.

The change-over can also be done manually by pressing the emergency manual override
(6).

Electrically operated

27/01/14 121
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] 50 [13.21]
With YZ 315 [4 568]
Operating pressure bar [PSI]
Without YZ 250 [551]
Oil temperature range °C [°F] -20 to +70 to +158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Mounting position Optional
Mass kg [lb] 2,7 [5.95] (N1)
Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
29
Power W
(12 V DC supply voltage) 36
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to +50 [to+122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

Dimensions

Threaded connections M

Threaded connections YZ

LA= 39,5 (G3/8, M18x1,5)


37,5 [1.47] (G1/2, M22x1,5)

3. Solenoid ’’a’’ MR-045


6. Emergency manual override
7. Plug-in connector <<a>>-grey
8. Nameplate
9. O-Ring ; M18x1,5 / G3/8 = Ø21x2
Screws

M22x1,5 / G1/2 = Ø26x2


10. O-Ring ; M14x1,5 / G1/4 = Ø17x2
11. Valve cap

122 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

.Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].]

Mechanically operated
Diff. pressuree

Flow

Model code

K V H - 6 / 2 - 6 - - - - - - - S 5 0 - - -
*
symbol

No designation

Hydraulically operated
AB
Special
requirements to be
briefly specified

Overlap Number of units


N1 One
No designation
N2 Two
N3 Three
P N4 Four
N5 Five

Manual override option


Emergency manual override No designation Seal type
Manual override with rubber cover G No NBR seals for mineral oil HL,
designation HLP to DIN 51524
Lockable manual override C
FPM seals for HETG, HEES,
E HEPG to VDMA 24568 and
Supply voltage ISO 15380
Direct voltage 24V No designation
Direct voltage 12V 12 DC Drainage
Electrically operated

No designation Without YZ
YZ With YZ
Connector type
EN 175301-803 without signal lampp No designation
Threaded connections M ; YZ
EN 175301-803 with signal lamp L
No designation M18x1,5; M14x1,5
EN 175301-803 without connector K
M22 M22x1,5; M14x1,5
AMP Junior timer without connector M
3/8 G3/8; G1/4
Deutsch V
1/2 G1/2; G1/4
SAE 8 3/4-16 UNF-2b; 9/16-18 UNF-2B
Overvoltage protectionWithout
overvoltage protection
Without overvoltage protection No designation
With overvoltage protection T

27/01/14 123
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

124 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/2 WAY DIRECTIONAL VALVES KVH (NG 10)

• NG 10
• Up to 315 bar [4 568 PSI]

Mechanically operated
• Up to 120 L/min [31.70 GPM]

• Plug-in connector for solenoids to ISO 4400.


• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP 65 to EN 50529 / IEC 60529.

KVH-6/2-10-N2

Operation Hydraulic symbol

Directional valves type KVH with direct solenoid operation control the direction of the
hydraulic medium flow. They are mostly used as link between two consumers and the
basic directional valve, when we want to control both consumers alternately by means of
one basic directional valve.

The KVH type directional valves consist of a housing (1), a control spool (2), and a
solenoid (3) with return spring (5).

Change-over to the operating position is done by energizing the solenoid (3), whereby the
solenoid plunger acts on the control spool (2) via the operating pin (4), thus clearing the
corresponding flow ways and establishing respective links between the ports
P1, A, B and P2.

Hydraulically operated
Mounting example
When the solenoid (3) is de-energized, the control spool (2) is returned to its neutral
position by the return spring (5), thus establishing again the links between ports
P1, C, D and P2.

The change-over can also be done manually by pressing the emergency manual override
(6).

A
A B

6 3 4 1 2 5
Electrically operated

C D

C D YZ

A B

P1 P2 YZ

P1 P2 YZ

27/01/14 125
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 10
Flow rate L/min [GPM] 120 [31.70]
With YZ 315 [4 568]
Operating pressure bar [PSI]
Without YZ 250 [551]
Oil temperature range °C [°F] -20 to +70 [-4 to+158]
15 to 380 [3.24 to 82]
Viscosity range mm2/s [SUS]

Mounting position Optional


Mass kg [lb] 5,5 [12.12]
Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
Power W 45
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

Dimensions
[0.59]

122 (with hand operation)


15

Mmax=50Ncm Threaded connections M


116 [4.57]
Pg 9 (P1)34 (P2) 46 Threaded connections YZ
[1.34] [1.81]
[cca. 4.06]
cca. 103

68.5 [2.7]
32 [1.26]

M8x12 /15 (z=2)


108[4.25] 130 [5.12]
246 [9.68]
[0.75 max.]

(A) 54[2.13] (B) 46 [1.81]


max.19

3 2 1 4 (C) 34 (D) 46
[1.34] [1.81] 7 Mmax. = 20Nm

5
C D YZ

8
A B
n x 73 [n x 2.87]

6 1. Solenoid ’’a’’ MR-060


P1 P2 YZ 2. Plug-in connector «a» - grey
C D YZ 3. Emergency manual override
4. Nameplate
73 [2.87]

[1.97 ±0.01 ]

5. O-Ring ; 26x2 = KVH-6/2-10-G1/2 (M22)


50±0.2

31x2 = KVH-6/2-10-G3/4 (M27)


A B
6. O-Ring 17x2
[1.44]
36.5

7. Screws M10 - 10.9 (z=4)


P1 P2 YZ 8. Valve cap
[0.45]
11.5
[0.75 max.]

18.5 67 ±0.2
max.19

[0.73] [2.64 ±0.01]

126 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Pressure drop

Flow

Model code

K V H - 6 / 2 - 10 - - - - - S 4 0 - - -
*
Manual override option
Emergency manual override No designation
Manual override with rubber cover G

Hydraulically operated
Lockable manual override C

Supply voltage
Direct voltage 24V No designation
Direct voltage 12V 12 DC
Special
Connector type requirements to be
EN 175301-803 without signal lamp No designation briefly specified
EN 175301-803 with signal lamp L
175301-803 without connector K
AMP Junior timer without connector M
Deutsch V

Overvoltage protection Number of units


Without overvoltage protection No designation N1 One
With overvoltage protection T N2 Two
N3 Three
Threaded connections M; YZ N4 Four
M22x1,5; M14x1,5 M22 N5 Five
M27x2; M14x1,5 M27
G1/2; G1/4 G1/2
Electrically operated

G3/4; G1/4 G3/4


7/8-14 UNF-2B; 9/16-18 UNF-2B SAE 10

Drainage
Without YZ No designation
With YZ YZ

Seal type
NBR seals for mineral oil HL, HLP to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA 24568
E
and ISO 15380

27/01/14 127
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

128 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

6/3 WAY DIRECTIONAL VALVES KV (NG 4)

• NG 4
• Up to 210 bar [3045 PSI]

Mechanically operated
• Up to 7 l/min [1.8 GPM]

• Plug-in connector for solenoids to ISO 4400.


• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas).
• Manual emergency control.
• Fulfil EMC (89/336/EEC).

KV-6K/3-4

Features Hydraulic symbol

Hydraulic
Size 4
Flow rate L/min [GPM] 7 [1.8]
Operating pressure bar [PSI] 210 [3 045]
2 15 to 380 [69.5 to 1 760]
Viscosity range mm /s [SUS]

Oil temperature range °C [°F] -20 to+70[-4 to 158]


Filtration ISO 4406-1999 19/17/14

Hydraulically operated
Mass kg [lb] 1,6 [3.5]
Seal type NBR seals for mineral oil HL, HLP, to DIN 51524

Electrical
Supply voltage V 12, 24
Power W 25
Switching frequency 1/h 15 000
Ambient temperature °C [°F] to 50 [122]
Coil temperature °C [°F] to 180 [356]
Duty cycle Continuous

P-Q Performance curves


Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].
Electrically operated
Diff. pressure

Flow

27/01/14 129
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Dimensions

Emergency manual override

Model code

K V - 6 K / 3 - 4 - - -
*
Working ports
Six working ports 6
Special requirements to be
briefly specified
Number of control spool position
Three positions 3

Supply voltage
Direct voltage 24V 24 DC
Threaded connections A, B, P
Direct voltage 12V 12 DC
No designation M14x1,5; -
1/4 G1/4; -
Connector type SAE 6 9/16-18 UNF-2B; 9/16-18 UNF-2B
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP Junior timer without connector M
Deutsch V

Overvoltage
Without overvoltage protection No designation
With overvoltage protection T

130 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

8/3 WAY DIRECTIONAL VALVES KV (NG 6)

• NG 6
• Up to 250 bar [3 625 PSI]

Mechanically operated
• Up to 50 l/min [13.2 GPM]

• Plug-in connector for solenoids to ISO 4400.


• Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas), ISO 11926 (UNF).
• Protection of solenoid IP65 to EN 50529 / IEC 60529.
• Fulfil EMC (89/336/EEC).

KV-8/3-6

Operation Hydraulic symbol

Directional valves type KV with direct solenoid operation control the direction of the
hydraulic medium flow. They are mostly used as link between three consumers and the
basic directional valve, when we wish to control both consumers alternately by means of
one basic directional valve.

The KV type directional valves consist of a housing (1), a control spool (2,3), two solenoids
(4,5) with return spring (6,7). Change-over to one of the operating positions is done by
combination of operation of solenoids (4,5), whereby the solenoid plunger acts on the
control spool (2,3) via the operating pin (8), thus clearing the corresponding flow ways and
establishing respective links between the ports P1, A, B, C, D, E, F and P2, as seen forth in
the schematic diagram of a mounting example.

Hydraulically operated
When the solenoid (4,5) is de-energized, the control spool (2.3) is returned to their neutral
position by the return spring (6,7).

The change-over can also be done manually by pressing the emergency manual override Mounting example
(9).

Electrically operated

27/01/14 131
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

Features

Hydraulic
Size 6
Flow rate L/min [GPM] 50 [13.21]
Operating pressure bar [PSI] 250 [3 625]
Oil temperature range °C [°F] -20 to +70 [-4 to+158]
Viscosity range mm2/s [SUS] 15 to 380 [3.24 to 82]
Mounting position Optional
Mass kg [lb] 3,8 [8.38]
Filtration NAS 1638 8

Electrical
Supply voltage V 12, 24 DC
29
Power W
(12 V DC supply voltage) 36
Switching frequency 1/h 15000
Ambient temperature °C [°F] to +50 [to +122]
Coil temperature °C [°F] to +180 [to +356]
Duty cycle Continuous

Dimensions

Threaded connection

4.5. Solenoid ’’b’’ MR-045


9. Emergency manual override
10. Plug-in connector «b» - black
11. Nameplate
12. Valve cap

132 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

P-Q Performance curves

Measured at 50°C [122°F] and viscosity of 32 mm2/s [148 SUS].

Mechanically operated
Pressure drop

Flow

Model code

K V - 8 / 3 - 6 - - - - -
*
Manual override option
Emergency manual override No designation
Manual override with rubber cover G
Lockable manual override C

Hydraulically operated
Supply voltage
Direct voltage 24V No designation
Direct voltage 12V 12 DC

Connector type
EN 175301-803 without signal lamp No designation
EN 175301-803 with signal lamp L
EN 175301-803 without connector K
AMP Junior timer without connector M
Deutsch V
Overvoltage
Without overvoltage protection No designation
With overvoltage protection T

Threaded connections
M18x1,5 No designation
M22x1,5 M22
M20x1,5 M20
Electrically operated

G3/8 G3/8
G1/2 G1/2
3/4-16 UNF-2B SAE 8

Seal type
NBR seals for mineral oil HL, HLP, to DIN 51524 No designation
FPM seals for HETG, HEES, HEPG to VDMA
E
24568 and ISO 15380

Special requirements to be briefly specified

27/01/14 133
Directional control valves - Hydraulic components POCLAIN HYDRAULICS

134 27/01/14
POCLAIN HYDRAULICS Hydraulic components - Directional control valves

Mechanically operated
Hydraulically operated
Electrically operated

27/01/14 135
Poclain Hydraulics reserves the right to make any modifications it deems necessary to the products described in this document
without prior notification.The information contained in this document must be confirmed by Poclain Hydraulics before any order is
submitted.
Illustrations are not binding.
The Poclain Hydraulics brand is the property of Poclain Hydraulics S.A.

27/01/14

A35758S
A35771G

www.poclain-hydraulics.com

You might also like