DCM750 User's Manual
DCM750 User's Manual
DCM750 User's Manual
User Manual
1.1 Outline..................................................................................................................................................................... 1
1.2 Features....................................................................................................................................................................1
1.5 Specifications...........................................................................................................................................................2
3.1 login.......................................................................................................................................................................... 7
3.2 Operation.................................................................................................................................................................8
CHAPTER 4 TROUBLESHOOTING......................................................................................17
DCM750 IPTV Gateway User’s Manual
1.1 Outline
DCM750 is a powerful, yet low power consumption, rack-mount IPTV Gateway Controller&
Control Interface for 24/7 operation. Its modular design enables integrators and operators to
select from various protocol to customise operation and on-going service.
It can convert the broadcast network IP stream over HTTP, UDP, RTP, RTSP and HLS and TS
file into HTTP, UDP, HLS and RTMP protocol. The platform can achieve the integration by
receiving a variety of commercial streaming media services, and can provide streaming media
services directly.
Designed for the centralised control of Android STB’s the control protocol conversion function
acts, used for the protocol conversion scenarios and streaming media distribution scenarios, to
the commonly deployed STB’s in the hotel, hospitality, corporate, education and entertainment
sectors.
1.2 Features
1
DCM750 IPTV Gateway User’s Manual
1.5 Specifications
Play programs with APK downloaded android STB and TV, maximum 150
terminals
Support about 80 HD/SD programs (Bitrate: 2Mbps) When
HTTP/RTP/RTSP/HLS is converted into UDP (Multicast), the actual application
shall prevail, and suggest maximum 80% CPU utilization
web-based NMS management thru DATA port
Demission 482mm×324mm×44mm (WxLxH)
General Temperature 0~45℃(operation), -20~80℃(storage)
Power Supply AC 100V±10%, 50/60Hz or AC 220V±10%, 50/60Hz
3
DCM750 IPTV Gateway User’s Manual
When users open the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
DCM750 IPTV Gateway
User’s Manual
Grounding Cable
Power Cord
If any item is missing or mismatching with the list above, please contact local dealer.
When users install device, please follow the below steps. The details of installation will be
described at the rest part of this chapter. Users can also refer rear panel chart during the
installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing gateway
Connecting signal cables
4
DCM750 IPTV Gateway User’s Manual
Item Requirement
When user installs machine frame array in one machine hall, the
Machine Hall Space distance between 2 rows of machine frames should be 1.2~1.5m
and the distance against wall should be no less than 0.8m.
Relative
20%~80% sustainable 10%~90% short time
Temperature
Pressure 86~105KPa
All function modules’ good grounding designs are the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
Coaxial cable’s outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be
5
DCM750 IPTV Gateway User’s Manual
antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no less
than 25mm2.
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and avoid circling. The area of the conduction between
grounding wire and grounding strip should be no less than 25mm2.
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is
on the left ,power supply socket is on the right and the fuse is just between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to DCM750 IPTV Gateway, user should set the power
switch to “OFF”.
6
DCM750 IPTV Gateway User’s Manual
3.1 login
The default IP of this device is 192.168.200.136:3333 (3333 is IP port number which can’t be
changed)
Connect the PC (Personal Computer) and the device with net cable, and use ping command to
confirm they are on the same network segment.
I.G. the PC IP address is 192.168.200.136, we then change the device IP to 192.168.200.xxx
(xxx can be 0 to 255 except 136 to avoid IP conflict).
Use web browser to connect the device with PC by inputting this device’s IP address in the
browser’s address bar and press Enter.
It displays the Login interface as Figure-1. Input the Username and Password (Both the
default Username and Password are “admin”.) and then click “Login” to start the device
setting.
Figure-1
7
DCM750 IPTV Gateway User’s Manual
3.2 Operation
System Chart
When we confirm the login, it displays the status interface where users can have an overview
of system chart. (Figure-2)
Figure-2
8
DCM750 IPTV Gateway User’s Manual
Figure-3
Figure-4
Figure-5
: Click box in front of program number, and then click it to batch programs information as
10
DCM750 IPTV Gateway User’s Manual
11
DCM750 IPTV Gateway User’s Manual
Figure-6
Input contents
Figure-7
“Add” and then upload it. After submitting, boot images will appear when starting dibsys
IPTV APK. (Figure-8)
Figure-8
conversion” or “HTTP”
Figure-9
Select boot setting as “Boot Video” to upload boot video here and it will appear when
starting dibsys IPTV APK. Suggest the size of video file doesn’t over 500M.
13
DCM750 IPTV Gateway User’s Manual
Figure-10
14
DCM750 IPTV Gateway User’s Manual
Figure-11
Clicking “Download APK”, it will trigger a box as below (select saving pass) to save IPTV
APK flie.
15
DCM750 IPTV Gateway User’s Manual
Figure-12
System Information
Clicking “System Information”, it displays the interface where users can check the system
information such as CPU usage rate, CPU usage record and so on. (Figure-13)
Figure-13
16
DCM750 IPTV Gateway User’s Manual
Chapter 4 Troubleshooting
dibsys’s ISO9001 quality assurance system has been approved by CQC organization. For
guarantee the products’ quality, reliability and stability. All dibsys products have been passed
the testing and inspection before ship out factory. The testing and inspection scheme already
covers all the Optical, Electronic and Mechanical criteria which have been published by
dibsys. To prevent potential hazard, please strictly follow the operation conditions.
Prevention Measure
Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores
if necessary
Checking the input AC within the power supply working range and the connection is
correct before switching on device
Checking the RF output level varies within tolerant range if it is necessary
Checking all signal cables have been properly connected
Frequently switching on/off device is prohibited; the interval between every switching
on/off must greater than 10 seconds.