EVC-ICC-A5 User Manual V1.0.

0ENG

Intelligent Elevator Control Module

User Manual

Dnake (Xiamen) Intelligent Technology Co., Ltd.


Tel: +86-592-5705812 Email: support@dnake.com
Fax: +86-592-5705812 URL: http://www.dnake-global.com
Address: North Gate, No.1, Haijing Road, Haicang District, Xiamen, 361026, Fujian, China

1
EVC-ICC-A5 User Manual V1.0.0ENG

Index

1.General....................................................................................................................3
2.Standard Specification ............................................................................................3
3.Functions ................................................................................................................4
4.Dimensions .............................................................................................................5
5.Installation.............................................................................................................. 5
6.Wiring Diagram .......................................................................................................6
7. Quick use steps........................................................................................................9
8.Parameter Settings ............................................................................................... 11
8.1 Main ............................................................................................................ 11
8.2 Network....................................................................................................... 11
8.3 Device ......................................................................................................... 12
8.4 Settings ....................................................................................................... 12
8.4.1 EVRC mode...................................................................................... 13
8.4.2 EVDC mode(Type: only control Down Button of elevator ) ............... 17
8.4.3 EVDC mode(Type: control UP & Down Buttons of elevator ) ........... 18
8.5 Card ............................................................................................................ 20
8.6 Logout ......................................................................................................... 22
9.System Connection ............................................................................................... 22

2
EVC-ICC-A5 User Manual V1.0.0ENG

1.General
The elevator is one of the main tools for people in vertical moving. The wide use of
the elevator system brings people a lot of convenience and benefits. In most cases, when
using the elevator, it's short of measures in safety management and intelligence as well
as personal access and permission management.
With POE power supply, the equipment uses TCP/IP to communicate and establish
system network. It supports network expansion and elevator call permission control by
elevator cab button. (Two 485 interfaces are available for extending card interface and
communication interface. It identifies the users through IC/ID card and the password,
then gives the access permissions.It communicates data and configures the network
through 485 bus.)
2.Standard Specification
Channels 16

Operation Parameters are stored by EEPROM for more than 10


Parameter Storage
years

Enclosure IP30

Weight 0.5 Kg

Dimensions 197mm(L)*89mm(W)*37mm(H)

Ambient Temperature -40 ~+70 ℃


Ambient Humidity 20% to 93%

Power Supply POE(Optional 24VDC)

Communication RS485*2 & TCP/IP

Control Method Relay(1A 120VAC;1A 24VDC)

Firmware Upgrade USB/Ethernet

Remote Management Yes

Network Ethernet (10/100Base-T) RJ-45

RS485 Communication 2 channels

Standby Consumption 4W

Max Consumption (NC ) 7W

Mini Consumption (NO) 1W

3
EVC-ICC-A5 User Manual V1.0.0ENG

3.Functions

No. Function No. Function


Network Port for Communication and B1~B16,16-channels relay for
① ⑤
POE Power Supply controlling elevator key panel
② Reserved(12VDC power supply) ⑥ Reserved(24VDC power supply)
RS485+ & RS485-,Used to connect ID/IC
③ ⑦ Fire Switch
card reader
RS485+ & RS485-, Used for Indicator
④ communication with DNAKE outdoor ⑧ Red: power supply(always on)
panel or computer serial port Green: communicating(flashing)

4
EVC-ICC-A5 User Manual V1.0.0ENG

4.Dimensions

5.Installation

DIN rail installation

5
EVC-ICC-A5 User Manual V1.0.0ENG

6.Wiring Diagram

Connect to Outdoor Panel or Computer

Connect to Elevator
Working mode:EVDC (Control Down Button)

6
EVC-ICC-A5 User Manual V1.0.0ENG

Working mode:EVDC (Control UP & Down Buttons)

Working mode:EVRC

7
EVC-ICC-A5 User Manual V1.0.0ENG

Fire Switch

Connect to ID/IC Card Reader

8
EVC-ICC-A5 User Manual V1.0.0ENG

7.Quick use steps

Working logic:
Unlock from the indoor monitor(or click “call elevator” icon).
Monitor will sends command to Outdoor panel,then Outdoor panel sends command to
EVC IP Relay Module via network(or RS485 command at the same time);then the
corresponding relay will be triggered.
Step 1:
Connect the EVC ip relay module and PC to network switch.

Step 2:
Use our Search Tool to find IP address of EVC module
The ID number is E×××× for the EVC module. You can query the device ID, Mac address
and IP address.

Step 3:
Change the local IP address of the PC on the same network segment according to the IP
address of the device.

9
EVC-ICC-A5 User Manual V1.0.0ENG

Step 4:
Input the IP address of EVC to the browser, then input the user name and password(the
default name is “admin”,the password is “123456”) to into the following interface:

10
EVC-ICC-A5 User Manual V1.0.0ENG

8.Parameter Settings

8.1 Main

The system and software information:

8.2 Network

Network Settings:
DHCP: enable / disable DHCP function
IP: IP address should be unique in the same network
Mask: according to the actual network situation
Gateway: according to the actual network situation
DNS: according to the actual network situation

Click the submit button to complete parameter modification:

11
EVC-ICC-A5 User Manual V1.0.0ENG

8.3 Device

Lift control device settings:


Build: Building number of EVC ( the same with the outdoor panel which is used
together.),range 1~999
Riser: Unit number of EVC,range 0~99
Device Address: range 0~98

Click the submit button to complete parameter modification:

8.4 Settings

12
EVC-ICC-A5 User Manual V1.0.0ENG

Lift control Settings:

Mode: Working mode EVRC or EVDC


EVRC:Usually used to control the internal call panel of elevator
Use contacts:Choose the type of contacts
Type:Control down and up key of lift’s external call panel,or only control down key
of lift’s external call panel
Relay time:The default time is 500ms,which is used to stimulate the time of
pressing up and down key.
EVDC:Usually used to control the external panel of elevator
Select the EVRC/EVDC mode and click the submit button, the corresponding parameter
setting interface will appear.
Use contacts:Choose the type of contacts
Type:Control Automatically or Control Manually
Use:Configure the settings based on Floor and Apartment
Lift release time (card):The duration of triggering with card
Lift release time (intercom): The duration of triggering via intercom
Energise all relays(FailSafe):if you want the relay status to be opposite when
power it,enable it,if not,leave it alone. (Usage: On EVRC mode of the elevator
module, when you enable this option, you can use the NC port of the relays as an NO
port to connect the Floor buttons inside the elevator. In this way, the module in the
case of failure or power will not affect the normal use of the elevator.)

8.4.1 EVRC mode


Lift release time (card): 0~9999 (default 5s)seconds
Lift release time (intercom):0~9999 (default 1s)seconds
use Contacts COM/NO:When receiving the corresponding trigger command, the
normally-open (NO) relay will activate.
use Contacts COM/NC:When receiving the corresponding trigger command, the
normally-closed (NC) relay will activate.
Type:Control Automatically or Control Manually
Use:Configure the settings based on Floor and Apartment
Energise all relays(FailSafe):
When EVC enables this function, all relays are in the opposite state.
When EVC is Powered on with this function enabled,all relays are in the opposite
state. use Contacts COM/NO:When receiving the corresponding trigger command, the
normally-closed (NC) relay will activate. 13
EVC-ICC-A5 User Manual V1.0.0ENG

use Contacts COM/NC:When receiving the corresponding trigger command, the


normally-open (NO) relay will activate.
The relay will be restored to its original state after Power OFF.

If “Use” at “Settings” is configured as “Floor”,you will see “Advanced” as follow:

If “Use” at “Settings” is configured as “Apartment”,you will see “Advanced” as follow:

When “Type” is configured as “Automatic”,the table will display as follow. In this


configuration,the two relays at lift controller will be triggered at the same time,B1 and
B9,B2 and B10,B3 and B11…will be triggered in pairs at the same time.

Select button: Setting Upload File Path


Import: After setting the file path, click Import to upload the file.Only support “.csv”
format file.

14
EVC-ICC-A5 User Manual V1.0.0ENG

Export: Export configuration file (.csv)


Port: Select port 1~16(B1~B16)
Floor/Apartment: Support 1 to 4 digits that is the same as the indoor monitor’s room
number

For Example:

Indoor Monitor

IP Address: 192.168.98.190
Building Number: 1
Unit: 1
Room: 101
Device: 0

Outdoor Panel:

IP Address: 192.168.98.54
Building: 1
Unit: 1

15
EVC-ICC-A5 User Manual V1.0.0ENG

EVC Module:
IP Address:192.168.98.231
Building:1
Riser(Unit):1

Calling room number 101 from the outdoor panel.When indoor monitor unlocks the door,
when “Type” is configured as “Manual”,the EVC relay Port1 (B1) normally-open contact
will work,and visitors can press the floor button he want to visit,in this example,he will
have access to press floor 1;When “Type” is configured as “Automatic”, the EVC relay
Port1 (B1) and Port9 (B9) normally-open contact will work at the same time,vistors no
need to do any operation.

Permit button: Permission to open the floor where the indoor monitor is located

16
EVC-ICC-A5 User Manual V1.0.0ENG

8.4.2 EVDC mode(Type: only control Down Button of elevator )

17
EVC-ICC-A5 User Manual V1.0.0ENG

Parameter settings are the same as EVRC.


Click indoor monitor Elevator icon(only Down button enable) , the EVC relay Port1 (B1)
normally-open contact will work.

8.4.3 EVDC mode(Type: control UP & Down Buttons of elevator )

18
EVC-ICC-A5 User Manual V1.0.0ENG

Parameter settings are the same as EVRC.


Click indoor monitor Elevator icon(Down button) , the EVC relay Port1 (B1) normally-
open contact will work.
Click indoor monitor Elevator icon(UP button) , the EVC relay Port9 (B9) normally-open
contact will work.

Note:
Port 1(B1) corresponds to port 9(B9)
Port 2(B2) corresponds to port 10(B10)
Port 3(B3) corresponds to port 11(B11)
Port 4(B4) corresponds to port 12(B12)
Port 5(B5) corresponds to port 13(B13)
Port 6(B6) corresponds to port 14(B14)

19
EVC-ICC-A5 User Manual V1.0.0ENG

8.5 Card

20
EVC-ICC-A5 User Manual V1.0.0ENG

The controller supports to connect with a card reader via RS485 to realize that the
residents can swipe their fobs at lift car to call the lift/elevator,and the controller will
provide access to the floor where the fobs are bound with.
You can Export and Import the card list here,and also Add the fobs/cards here manually
and automatically.
If you want to Add the fobs/cards automatically,pls make sure the controller and card
reader is connected correctly,and then press “Start read” to start reading card No.,swipe
the fob/card above card reader,a card adding interface will come out automatically,you
can only input apartment No.,then press “Add” to add this card to the card list.

Note:1. The card list only works at “EVRC” mode.


2.Make sure the RS485 port is existing at the controller,because some old version
doesnot support RS485 now,because some components are not patched before.