Secop Compressors Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 180

WITH MORE THAN 50 ADVANCED COMPRESSOR

YEARS OF EXPERIENCE IN TECHNOLOGIES TO ACHIEVE


COMPRESSOR TECHNOLOGY STANDARD SETTING
AND HIGHLY COMMITTED PERFORMANCE FOR LEADING
EMPLOYEES, OUR FOCUS IS PRODUCTS AND BUSINESSES
TO DEVELOP AND APPLY THE AROUND THE WORLD.

HERMETIC COMPRESSORS
FOR AC VOLTAGE

R134a | R404A | R507 | R407C


R290 | R600a

www.secop.com SETTING THE STANDARD


TABLE
OF CONTENTS

P / T / X / D / N / F / S / G-Series KAPPA / DELTA


1. Secop hermetic reciprocating Compressors........................ 3 Secop hermetic reciprocating Compressors made in Austria
1.1 Voltages and frequencies............................................... 4
1.2 Refrigerants.................................................................... 4
1.2.1 Handling of refrigerants................................................. 4 General Product Documentation KAPPA................................ 35
1.2.2 Charging with refrigerant............................................... 4 1. Compressor denomination / Label........................................ 36
1.2.3 Replacement of refrigerant............................................ 4 2. Motor types / Approvals.......................................................... 37
1.2.4 Flammable refrigerants R290 and R600a..................... 5 3. Delivery conditions / Applications conditions........................ 38
1.3 Connectors...................................................................... 5 4. Drawings................................................................................. 39
1.4 HFC refrigerants (R134a) . ............................................... 6 5. Transport, packing, palletization............................................ 42
1.5 Compressor designations.................................................. 6 Accessories KAPPA................................................................. 44
1.6 Design............................................................................. 6 1. Electrical components............................................................ 45
1.7 Compressor dimensions.................................................. 6 2. Electric terminal circuit diagram / Mounting accessories.... 46
1.8 Type label........................................................................ 6 3. Evaporation tray...................................................................... 47
1.9 Date code & country of origin........................................... 8
1.10 Denomination.................................................................. 8
General Product Documentation DELTA................................. 48
2. Application Range............................................................... 10
1. Compressor denomination / Label........................................ 49
3. Motors Breakdown Torque................................................. 12
2. Motor types / Approvals / Delivery conditions....................... 50
4. Precondition for long operating Life................................... 14
3. Drawings................................................................................. 51
4.1 Motor overload.............................................................. 14
4. Transport, packing, palletization............................................ 54
4.2 Thermal overload.......................................................... 14
5. Electrical components / Electric terminal circuit diagram... 56
5. Design Limits...................................................................... 15
6. Accessories............................................................................. 57
5.1 Coil temperature............................................................ 15
7. Brazing and refrigerant charge.............................................. 59
5.2 Condensing temperature............................................... 15
6. Electrical Equipment / Motor Systems............................... 16
6.1 LST (RSIR)...................................................................... 16
6.2 LST (RSCR)..................................................................... 16
6.3 HST (CSR)...................................................................... 16
6.4 HST (CSIR)...................................................................... 17
6.5 Connections .................................................................. 17
6.6 Approvals....................................................................... 17
6.7 ePTC.............................................................................. 18
6.8 Run capacitor holder ..................................................... 18
6.9 Survey of starting capacitors........................................ 19
6.10 Survey of run capacitors................................................. 19
6.11 Electronic units / Controllers (variable speed)................ 23 Compressors Catalogue 220-240 V........................................... 60
7. IP44 Equipment for SC Compressors................................. 24 R134a · 220-240 V · 50 Hz...................................................... 60
8. Twin Compressors.............................................................. 25 R600a · 220-240 V · 50 Hz...................................................... 78
9. Moisture and Impurities .................................................... 26 R404A/R507 · 220-240 V · 50 Hz............................................ 98
R290 · 220-240 V · 50 Hz...................................................... 112
10. Condition at Delivery / Warnings ....................................... 27
R407C · 220-240 V · 50 Hz.................................................... 122
11. Max. Refrigerant Charge ................................................... 28 R134a · 220-240 V · 60 Hz.................................................... 126
12. Conversions........................................................................ 29 R404A/R507 · 220-240 V · 60 Hz.......................................... 136
13. Mounting............................................................................. 30
13.1 Connector positions...................................................... 30 Compressors Catalogue 115 V................................................ 144
14. Mounting Accessories........................................................ 31 R134a · 115 V · 60 Hz............................................................ 144
15. Shipment Position of Refrigeration Appliances................. 32 R600a · 115 V · 60 Hz............................................................ 156
R404A/R507 · 115 V · 60 Hz................................................. 160
R290 · 115 V · 60 Hz.............................................................. 168

2
1.
SECOP HERMETIC RECIPROCATING
COMPRESSORS

The Secop range of hermetic reciprocating AC compressors packs a mighty punch in a small package.
Compact design, efficient motors and low energy consumption are the main features in hermetic
compressors that build on over 50 years of reliability and quality.

This catalogue contains information on Secop hermetic refrigeration compressors for fixed voltages ranging
from 115 V to 240 V.
The Secop hermetic refrigeration compressor programme consists of the types P / T / X / D / N / F / S and
G-Series compressors and designed for household or light commercia applications. All of the compressor
types are designed for refrigeration systems using the designated refrigerants listed below.

P T X D N F S G
Refrigerant R134a (typelabel stripe colour: blue), typelabel colour
chemical formula: CH2FCF3
Voltages & 220-240 V, 50 & 60 Hz yellow
Frequencies 115 V, 60 Hz green
Basic types 220- 240 V: PL, TL, TF, NL, NF, FR, SC, SC Twin | 115 V: PL, TF, TL, TT, NF, NL, NT, FF, SC

Refrigerant R404A/R507 (typelabel stripe colour: lilac), typelabel colour


chemical formula R404A: CHF2CF3 / CH3CF3 / CH2FCF3
chemical formula R507: CHF2CF3 / CH3CF3
Voltages & 220-240 V, 50 & 60 Hz yellow
Frequencies 115 V, 60 Hz green
Basic types 220- 240 V: PL, TL, TF, NL, NF, FR, SC, SC Twin | 115 V: PL, TF, TL, TT, NF, NL, NT, FF, SC

Refrigerant R407C (typelabel stripe colour: lilac), typelabel colour


chemical formula: CH2F2 / CHF2CF3 / CH2FCF3
Voltage & Frequency 220-240 V, 50 Hz yellow
Basic types SC, SC Twin

Refrigerant R290 (typelabel stripe colour: red), chemical formula: C3H8 typelabel colour
Voltages & 220-240 V, 50 & 60 Hz yellow
Frequencies 115 V, 60 Hz green
Basic types TL, DL, NL, SC

Refrigerant R600a (typelabel stripe colour: red), chemical formula: C4H10 typelabel colour
Voltages & 220-240 V, 50 & 60 Hz yellow
Frequencies 115 V, 60 Hz green
Basic types PL, TL, XV, DL, NL

Note: Direct current compressors and most variable speed compressors (except NLV and BD150F) have a grey label.

P / T / X / D / N / F / S / G-Series
1.1 Secop AC refrigeration compressors are designed for the main voltage 220 V 50 Hz and 115 V 60 Hz. The
Voltages and frequencies compressors can also be used at other voltages and frequencies. Thus 220 V compressors can also be used
on 240 V 50 Hz mains as the higher voltage tends to amplify the motor capacity. Some compressors can be
used on 60 Hz mains, for instance 220 V 60 Hz and 230 V 60 Hz, however dependent on the application, the
compressor, and the type. The rated voltages 100 V 50 Hz, 120 V 60 Hz, 127 V 60 Hz, 110 V 50 Hz and 127 V
50 Hz will strengthen the motors. The rated voltages 110 V 60 Hz and 100 V 60 Hz will weaken the motors. If
used at 50 Hz the motors will be strengthened but the compressor capacity will be reduced by approx. 17%.

1.2 In accordance with the Montreal Protocol the use of CFC refrigerants (chloro-fluoro-carbons) has been
Refrigerants discontinued. This also includes refrigerants such as R12 and R502. Within the foreseeable future HCFC
refrigerants (partly halogenated chloro-fluoro-carbons) can no longer be used in Europe. In order to observe
time limits for abandoning HCFC refrigerants, various refrigerants were developed to replace the old ones.

All new refrigeration units must operate with the remaining refrigerants, i.e. PFC (perfluorcarbons), HFC
(hydrofluoro-carbons), hydrocarbons or inorganic refrigerants.

In the case of HFC refrigerant R134a a long-term replacement for the ozone-depleting R12 has been found.
R134a has approximately the same thermodynamic properties as R12, which simplifies the conversion of
installations. Secop can offer a wide range of compressors designed for R134a refrigeration units.

Hydrocarbons are an eco­friendly alternative to the CFC/HCFC/HFC fluorocarbons linked to ozone damage.
Isobutane (R600a) is the hydrocarbon most frequently found in domestic fridges and freezers, whilst propane
(R290) is common in commercial heat pump-, air conditioning-, refrigeration- and freezer applications.

Until recently, the CFC refrigerant R502 was used in commercial refrigeration. There are some HFC-
mixtures which will – in the long run – replace R502. Among these mixtures are R404A and R507. Instead
of the HCFC refrigerant R22, R404A and R507 can also be used in commercial applications. CL and DL
compressors are designed for use in refrigeration systems working with R404A and R507.

1.2.1 To ensure reasonable refrigeration system life, the refrigerant must have a maximum moisture content
Handling of refrigerants of 20 ppm (20 mg/kg). Do not fill the refrigerant from a large container into a filling bottle through several
container sizes, as with every drawing-off the water content in the refrigerant is increased considerably.

1.2.2. Normally, charging with refrigerant is no problem with a suitable charge, provided that the charging amount
Charging with refrigerant of the refrigeration system equipment is known.

Always charge the refrigerant amount and type stated by the refrigerator manufacturer. In most cases
this information is stated on the refrigerator type label. The different compressor brands contain different
amounts of oil, so when converting to another brand it may be advisable to correct the amount of refrigerant.
Charge of refrigerant can be made by weight or volume.

Flammable refrigerants like R600a and R290 must always be charged by weight. Charging by volume must
be made with a refrigerant charging cylinder. The refrigerant R404A and all other refrigerants in the 400
series must always be charged as liquid.

If the charging amount is unknown, charging must be done gradually until the temperature distribution
above the evaporator is correct. However, mostly it will be more appropriate to overcharge the system and
then gradually draw off refrigerant until the correct charge has been obtained. The refrigerant charge must
be made with the compressor running, the refrigerator without load and with the door closed.

The correct charge is characterized by the temperature being the same from the inlet to the outlet of the
evaporator. At the compressor suction connector the temperature must be approx. ambient temperature.
Thus transfer of moisture to the refrigerator insulation is avoided.

Systems with an expansion valve must be charged with refrigerant until there are no bubbles in the sight
glass, which should be placed as close to the expansion valve as possible.

1.2.3. The best solution for a repair is to select the same refrigerant as used in the same system. Secop
Replacement of compressors are supplied, or were supplied, in versions for the refrigerant R12, R22, R502, R134a, R404A/
refrigerant R507/R407C and for the flammable refrigerants R290 and R600a. The refrigerants R12 and R502, which are
covered by the regulations in the Montreal Protocol, are only used in very few countries, and will eventually
be phased out of production altogether.

For heat pump systems the refrigerant R407C is now used instead of R22 and R502. The more
environmentally acceptable R134a has replaced R12, and the refrigerants R404A and R507 have replaced
R22 and R502 in many applications.

P / T / X / D / N / F / S / G-Series
1.2.4 R600a and R290 are hydrocarbons. These refrigerants are flammable and are only allowed for use in
Flammable refrigerants appliances which fulfil the requirements laid down in the latest revision of EN/IEC 60335-2-24. (To cover
R290 and R600a potential risk originated from the use of flammable refrigerants). Consequently, R600a and R290 are only
allowed to be used in household appliances designed for this refrigerant and fulfil the above-mentioned
standard. R600a and R290 are heavier than air and the concentration will always be highest at the floor.
R600a must only be stored and transported in approved containers and must be handled according to
existing guidelines.

Do not use open fire near the refrigerants R600a and R290. The refrigeration systems must be opened with a
tube cutter.

The flammability limits are approx. as follows,

Refrigerant R600a R290


Lower limit 1.5% by vol. (38g/m³) 2.1% by vol. (39 g/m³)
Upper limit 8.5% by vol. (203 g/m³) 9.5% by vol. (177 g/m³)
Ignition temperature 460°C 470°C

In order to carry out service and repair on R600a and R290 systems the service personnel must be properly
trained to be able to handle flammable refrigerants. This includes knowledge on tools, transportation of the
compressor and refrigerant, and the relevant regulations and safety precautions when carrying out service
and repair.

Do not use open fire when working with refrigerants R600a and R290!

Conversions from refrigerants R12 or R134a to R600a is not permitted, as the refrigerators are not approved
for operation with flammable refrigerants, and the electrical safety has not been tested according to existing
standards either. The same applies to conversions from refrigerants R22, R502
flammable_small_yellow.pdf or R134a
10.11.2014 to R290.
17:08:35

Secop compressors for the flammable C

refrigerants R600a and R290


are equipped with a yellow warning M

label as shown. Y

CM

MY

CY

CMY

1.3 Most compressors are supplied with sealed connectors, which consist of a thick walled copper plated steel
Connectors tube with great corrosion resistance and good solder ability. The connectors are welded in the compressor
housing and thus the welding cannot be destroyed by overheating during soldering operations. The sealing
is an aluminium cap which gives a tight sealing. The seal is easily removed with an ordinary pair of pliers or
with the tool shown in the figure.
Compressor with copper connectors are sealed with
rubber plugs.
Refer to chapter 13.1 for connector positions.

Oil cooler tubes are made of copper and the


connectors are sealed with rubber plugs. 220 V
compressors are normally supplied with millimetre
tubes, while 115 V compressors are supplied with
inch tubes. All connectors have a shoulder to
provide optimal soldering conditions. Drifting of the
connectors for more than 0.3 mm is not allowed.
Compressors with an “S” in the model denomination
and all NL/DL types have a direct intake system, which
means increased capacity. The suction connectors at
these compressors must be connected to the suction
line to prevent capacity loss.

For the refrigerants R600a and R290, process tubes can be closed with a LokRing® connection.
Soldering is not allowed on systems with flammable refrigerants.

P / T / X / D / N / F / S / G-Series
1.4 The HFC refrigerant R134a and HFC mixtures require Polyester type oil. Contamination of components and
HFC refrigerants (R134a) systems with mineral oil and alkylbenzols must be avoided. Greasy substances and other long-chained,
high molecular substances not dissolved must not be present. Manufacturing processes which require a
lubricant can be done with Polyester oil approved for the compressors. Procedures for mounting, evacuation
and charging must be carried out in such a way that contamination with chlorine refrigerants is avoided. HFC
refrigeration systems must always have a drier with 3 Angstrom Molecular Sieves.

1.5 The first letter (P, D, T, N, F, S or G) indicates the compressor series whereas the second indicates the motor
Compressor designations protection placing. Nominal displacement is indicated by a number, which – for practical reasons - has been
approximated to the actual displacement.
Between the indicators for compressor series and displacement the identification marking for the
optimization of the compressor is given.

The letter following the marking for nominal displacement indicates which refrigerant must be used as well
as the field of application of the compressor. LBP (Low Back Pressure) indicates the range of low evaporating
temperatures, MBP (Medium Back Pressure) the range of medium evaporating temperatures, and HBP
(High Back Pressure) the range of evaporating temperatures.
The extra “T” indicates a compressor intended for the tropics.

The final letter in the compressor marking provides information on starting torque. If, as standard, the
compressor is intended for LST and HST, this place is left empty.

“K” also indicates low starting torque (Capillary tube, LST = Low Starting Torque) and “X” high starting torque
(Expansion valve, HST = High Starting Torque)

1.6 All Secop hermetic reciprocating compressors for R404A/R507 and R407C from the TL, TF, NL, FR and SC
Design range are standard efficiency types. Furthermore, all compressors for R290 from the TL, NL and SC range
are standard efficiency types as well. All compressors for R134a with the denominations PL, PLE, TLS, TFS,
TLES, TTE, TLY, NL, NF and NLE are designs with semi direct intake. Compressors with the denomination
NLY and TTY are designs with direct intake. Using the wrong suction connector on TTY and NLY is not
allowed, as the compressor will not function. Using the wrong suction connector on PL, PLE, TLS, TTE, TFS,
TLES, TLY, NL, NF and NLE compressors will lead to reduced capacity and efficiency.

All compressors for R600a are designed with semi direct intake. Using the wrong suction connector will lead
to reduced capacity and efficiency. Please note that the suction and process connectors on all TLS, TFS, TLX,
TTE, TLES, TTY and TLY compressors have been interchanged as compared with the basic TL compressors.

1.7 The built in conditions (total height, weight, tube dimensions etc.) are specified in the individual datasheets
Compressor dimensions including dimensioned sketches.

1.8 All compressors for 220-240 V have a yellow label with the type designation. Compressors for 115 V have a
Type label green label with the type designation.
Direct current compressors and most variable speed compressors have a grey label.
The label for “R404A R507” or “R404A R407C
R507” has a lilac stripe. The label for “R134a”
has a blue stripe. The labels for “R290” and
“R600a” both have a red stripe.
The country of origin indicated on the
compressor paper label and on the
compressor varies depending on the
manufacturing place (see 1.9)

Barcode format
The Secop typelabel contains two barcode
lines. The first line is the full code number
of the compressor and the second line is the
compressor serial number. These barcodes
contain 8 characters each and are printed in
code 128.

Serial number
The compressor serial number will also be written in normal letters below the barcodes
The serial number contains 8 digits, written in characters 0...9 and A…Z, without I and O.

P / T / X / D / N / F / S / G-Series
1.9 Secop compressors have a manufacturing date code
Date code & country of stamping on the housing.
origin
The content of the coding (fig. 1) is 2 lines, with 6 and 7
characters each, according to the example below.

H4485C (6 characters)
051D11R (7 characters, 8 characters for BD Micro)

Composition on line 1
H4485: compressor type information
(102H4485 = H4485)
C: internal Secop code

Composition of line 2
05: production week
1: production year
D: production day
A= Monday, B = Tuesday, C= Wednesday, etc.
11: production hour 00 to 23 or
shift code -1, -2, -3
R: Secop compressors internal production
location code
A to G, U Germany A until week 50/2005
D until week 35/2006 Fig.1 Needle print coding on
U until week 08/2010 compressor housing
and country of origin
on type label
K to N Slovenia K until week 39/2012
L until week 34/2011
M until week 02/2012
N until week 02/2012

A, D, R, U Slovakia A from week 01/2006


D from week 38/2006
L from week 45/2011
M from week 09/2012
R from week 01/2005
U from week 12/2010

S, R Mexico R up to week 27/2004



Fig.2 Slovenia
W to Z China

On BD Micro compressors (code number 109Z....), the


production year is indicated by two digits, e.g. “11” for
2011 and a serial number behind the location code.

The country of origin (in capital letters) or the manufac-


turer will also be marked on the typelabel, examples: Fig.3 Slovakia

MADE IN SLOVENIA
- for compressors made in Slovenia (Fig.2)

MADE IN SLOVAKIA
- for compressors made in Slovakia (Fig.3)
Fig.4 China
Made by Secop | optional label “Made in China”
- for compressors made in China (Fig.4)

P / T / X / D / N / F / S / G-Series
1.10 Key to AC-Compressor Type Designation (P / D / T / N / F / S / G-Series)
Denomination
1 2 3
Compressor Protector location Optimization level
design
Internal External
PTC Relay PTC Relay Variable Standard > High
LST HST speed

semi-direct
Always
intake
P Ea)

T S

Semi-direct or direct intake


D T LV Eb) Ya)b) Xa)

Blank
N Ua)

F R

S C C LV E

Power supply semi-direct


Always
intake
G 1 phase 3 phase
S T

E = Energy-optimized
Standard
Blank =

S = Semi-direct intake
Y = High energy-optimized
X = High energy-optimized
U = High energy-optimized
Key to AC-Compressor Type Designation (X-Series)
1 2 3
Compressor Protector location Optimization level
design
Internal External
PTC Relay PTC Relay Variable Standard > High
LST HST speed
Blank

X V

1 The first letter of the denomination (P, T, D, N, F, S, G or X) indicates compressor series


2 The second letter indicates motor protection placing. LV or V means variable speed compressors
3 E, Y, X and U mean different energy optimization steps. S means semi direct suction. On all these
mentioned types the indicated suction connector has to be used. Using the wrong connector as suction
connector will lead to reduced capacity and efficiency.
4 A number indicates the displacement in cm3, but for PL compressors the number indicates the nominal
capacity.
5 The letter after the displacement indicates which refrigerant must be used as well as the field of
application for the compressor.

P / T / X / D / N / F / S / G-Series
4 5 6 7
Compressor size Application range Refrigerant Code letter Generation
for starting
characteristics
Capacity Displacement
at rating
point
20
C = LBP R22
30
35 CL = LBP R404A/R507
50
CM = LBP R22
2.5, 3, 3.5, 4, Blank >
CN = LBP/MBP R290 first
4.5, 4.8
5, 5.7, 6 CNL = LBP R290 generation
6.5, 7, 7.5
8, 8.7, 9, 10 D = HBP R22 Blank >
universal
DL = HBP R404A/R507/R407C (principal rule) .1 >
4, 4.8
5.7, 6.5 updated
F = LBP/(MBP) R134a
7.5, 8.7 first generation
9.4, 10 FT = LBP tropical R134a

5.2, 5.5 G = LBP/MBP/HBP R134a


5.7, 6, 6.1 K = LST .2 >
GH = Heat pumps R134a
7, 7.3, 8.0 characteristics second
8.4, 8.8, 9 GHH = Heat pumps optimized R134a (capillary tube) generation
9.5, 10, 11
13, 15 K = LBP/(MBP) R600a
6
KT = LBP/(MBP) tropical R600a .3 >
7.5
8.5 MF = MBP R134a third
10 X = HST generation
11 MK = MBP R600a characteristics
10 (expansion valve)
ML = MBP R404A/R507
12
15 .4 >
MN = MBP R290
18 fourth
21 S = LBP/HBP (service) R426A generation
R401A/R401B
18 R409A/R409B
21
26 ST = LBP tropical (service) R426A
R401A/R401B
34 R409A/R409B

a) = Run capacitor compulsory


b) = Run capacitor optional

4 5 6 7
Compressor size Application range Refrigerant Code letter Generation
for starting
characteristics
Capacity Displacement
at rating
point
X = LST & HST
5.0 Blank >
characteristics
7.2 K = LBP/(MBP) R600a first
(capillary tube &
8.0 generation
expansion valve)

5 LBP (Low Back Pressure) indicates the range of low evaporating temperatures, typically -10°C down to -35°C or even -45°C, for
use in freezers and refrigerators with freezer compartments. MBP (Medium Back Pressure) indicates the range of medium evapo
rating temperatures, typically -20°C up to 0°C, such as in cold cabinets, milk coolers, ice machines and water coolers. HBP (High
Back Pressure) indicates high evaporating temperatures, typically -5°C up to +15°C, such as in dehumidifiers and some liquid cool
ers. T as extra character indicates a compressor intended for tropical application. This means high ambient temperatures and
capability of working with more unstable power supply.
6 The next letter in the compressor denomination provides information on the starting torque. If, as principal rule, the compressor
is intended for LST (Low Starting Torque) and HST (High Starting Torque), the place is left empty.
The starting characteristics depend on the electrical equipment chosen. K indicates LST (capillary tube and pressure equalization
during standstill) and X indicates HST (expansion valve or no pressure equalization). Exception: X-Series compressors.
7 The final letter (separated by a dot) mentions the generation of the compressor.
9

P / T / X / D / N / F / S / G-Series
2.
APPLICATION RANGE

R290 CN
Compressors with denominations ending with CN are designed for low evaporating temperatures (LBP Low
Back Pressure) and medium evaporating temperatures (MBP Medium Back Pressure) for use in commercial
refrigerators, freezers, glass door merchandisers and similar applications in regions with normal supply
voltage.

CNL
Compressors with denominations ending with CNL are designed for low evaporating temperatures (LBP
Low Back Pressure) for use in commercial freezers and similar applications in regions with normal supply
voltage.

MN
Compressors with denominations ending with MN are designed for medium evaporating temperatures (MBP
Medium Back Pressure) for use in commercial refrigerators, freezers and similar applications in regions
with normal supply voltage.

R404A/R507 and R407C CL


Compressors with denominations ending with CL are primarily designed for low evaporating temperatures
(LBP Low Back Pressure) for use in commercial refrigerators, freezers and similar applications in regions
with normal supply voltage.

ML
Compressors with denominations ending with ML are primarily designed for medium evaporation
temperatures (MBP Medium Back Pressure) for use in commercial refrigerators, bottle coolers, ice
machines and similar applications.

DL
Compressors with denominations ending with DL are primarily designed for high evaporation temperatures
(HBP High Back Pressure) for use in commercial refrigerators, liquid coolers, dehumidifiers, refrigerated
display counters, vending machines, heat pumps and similar applications.

R600a K
All compressors for R600a have denominations ending with K after the number for displacement or capacity.
They are designed for low operating temperatures (LBP Low Back Pressure) for use in refrigerators, freezers
and similar applications.

KK
Compressors with endings K and KK are designed for regions with stable supply voltage.

KTK
Compressors with endings KTK are designed for less stable supply voltage and tropical conditions.

MK
Compressors with endings MK are designed for medium operating temperatures (MBP Medium Back
Pressure) for use in commercial refrigerators like bottle coolers.

Some of the smaller TLS-K, TLES-K, TLY-K and the PLE-K compressors are also released for medium
operating temperatures (MBP Medium Back Pressure).

None of the compressors are released for high evaporation temperatures (HBP High Back Pressure).

10

P / T / X / D / N / F / S / G-Series
R134a – 115 V F
R134a – 220-240 V Compressors with denominations ending with F are primarily designed for low evaporating temperatures
(LBP Low Back Pressure/ MBP Medium Back Pressure on small displacements) for use in refrigerators,
freezers and similar applications in regions with stable supply voltage.

FT
Compressors with denominations ending with FT are F-types designed for low evaporation temperatures
(LBP Low Back Pressure) for use in refrigerators, freezers and similar applications operating in regions with
unstable supply voltage.

FK
Compressors with denominations ending with FK are F-types designed for low evaporation temperatures
with LST starting characteristics (capillary tube)

FX
Compressors with denominations ending with FX are F-types designed for low evaporation temperatures
with HST starting characteristics.

G
Compressors with denominations ending with G are primarily designed for high evaporation temperatures
(HBP High Back Pressure) for use in liquid coolers, dehumidifiers, refrigerated display counters, vending
machines and similar applications. The compressors can also be used for ‘Heavy Duty’ purposes at low
evaporating temperatures for use in refrigerators, freezers and similar applications operating in regions with
unstable supply voltage.

R134a – 115 V GK
Compressors with denominations ending with GK are G-types designed for high evaporating temperatures
with LST starting characteristics (capillary tube).

GX
Compressors with denominations ending with GX are G-types designed for high evaporating temperatures
with HST starting characteristics (expansion valve).

R134a – 220-240 V GH
Compressors with denominations ending with GH are designed for high evaporating temperatures for
cooling of electronic cabinets and for use in heat pump systems.

GHH
Compressors with denominations ending with GHH are optimized versions of GH compressors.

MF
Compressors with denominations ending with MF are primarily designed for medium evaporation
temperatures (MBP Medium Back Pressure) for use in commercial refrigerators, bottle coolers, ice
machines and similar applications.

11

P / T / X / D / N / F / S / G-Series
3.
MOTORS BREAKDOWN TORQUE

The motor designation relates to the output at a load corresponding to half the breakdown torque. The
concept “breakdown torque” expresses the highest load the motor is capable of handling without stopping.
When testing a compressor in practice, motor breakdown torque should be sufficiently high to enable the
motor to handle extreme conditions.

The load the compressor is capable of withstanding is illustrated by “breakdown curves” and the operating
conditions the compressor is capable of withstanding are thus made clear. These curves are determined
by maintaining a constant suction pressure (evaporating temperature) and subsequently allowing the
compressor to work at an increasing back pressure on a constant voltage. If the load becomes too high, the
number of revolutions will fall while current consumption increases and finally the compressor will stop.
The figure illustrates the load limits for compressors TL - “F” and TL - “G” on various under voltages and the
same motor temperature. In addition, the limit for TL – “G” at 60Hz has been included in the diagram.

The diagram also shows a typical example of the load fluctuations to which a compressor is subjected from
start up to stationary operation in a refrigerant circuit with capillary tube throttling. The pressure sequence,
determined by the start condition and system composition, is called “system characteristics”. In this
example the start condition is determined by the occurrence of pressure and temperature equalization in the
refrigeration system at 43°C.

For a compressor to be able to handle the shown load sequence, it is a precondition that the breakdown
curve at a specific voltage does not intersect the system curve.

It can be seen from the figure that the sequence of the breakdown curve for a TL – “G” at 60 Hz is more or
less the same as the curve for a TL – “F” at 50Hz. In the example shown consideration should be given to
the inclusion of a G compressor if refrigeration appliances designed for 230V 50Hz are to be connected to a
220V or 230V 60Hz mains supply. Furthermore, improved under voltage properties are obtained at the same
frequency by the stronger motor of a G compressor, than is the case with a corresponding “F” compressor.
This is the reason why “G” types are an excellent solution in fields with heavier under voltage, while the “F”
type is used in household refrigeration and freezing appliances intended for countries with a more stable
power supply.

Higher motor torque will be required for operation at high evaporating temperatures (HBP) than for
operation at low evaporating temperatures (LBP). “G” compressors are suitable for this field and can thus be
characterized as R134a universal compressors.

Energy – optimized compressors are characterized by a minimum in mechanical and electrical losses but
high volumetric efficiency. With a view to achieving high motor efficiency, well defined application conditions,
limited under voltage and a proper system curve should be taken into consideration when dimensioning the
compressor. Here, the careful dimensioning of system components (condenser surface, condenser volume
and capillary tubes) is necessary.

12

P / T / X / D / N / F / S / G-Series
System and breakdown
characteristics

Fig. : Presentation of system and breakdown curves

Seen from this point of view, “F” compressors are a better solution in terms of energy consumption than the
“G” types, and are intended for household refrigeration appliances. In all cases the precondition for trouble
free operation is a stable supply voltage (min. 90% of line voltage) and suitable system dimensioning.

13

P / T / X / D / N / F / S / G-Series
4.
PRECONDITION FOR
LONG OPERATING LIFE

In order to achieve trouble free operation and long operating life for a hermetic compressor, the following
preconditions should be observed:

1. Sufficient starting torque of the compressor motor to allow the motor to start at the pressure conditions
in the refrigeration system.
2. Sufficient breakdown torque to allow the motor to handle the load conditions at start up and during
operation.
3. When the refrigeration system is in operation, the temperature in the compressor should not rise to levels
which could damage its components. Consequently, condensing and compression temperatures should
be kept as low as possible.
4. Precise dimensioning of the refrigeration system in question and careful evaluation of the operating
conditions of the compressor at expected maximum loads.
5. Sufficient cleanliness and low residual humidity in the circuit.

4.1 Compressor start up is influenced by the starting and/ or breakdown torque of the motor. If starting and/
Motor overload or breakdown torque is insufficient, the compressor either cannot start or the start will be hampered and
delayed because the motor protector is activated. Repeated start attempts subject the motor to overload,
which sooner or later will result in failure. Faults of this kind can mostly be avoided by using the correct
compressor/ motor combination. Secop offers the best solution for nearly all applications. It is a question of
selecting the correct compressor for difficult fields of application.

4.2 Operating conditions resulting in thermal decomposition of the materials used in the compressor must
Thermal overload be avoided to ensure long compressor life. The materials relevant in this relation are motor insulation,
refrigerant and oil.

The motor insulation consists of the insulating enamel for the copper wires, the slot liner of the stator iron,
bandages and feeder cables.

As early as 1960, Secop (Danfoss Compressors) introduced fully synthetic insulation materials on all
its compressors and the enamel for the wire insulation and the insulating system itself has improved
continuously ever since. The result is constantly improved protection against motor overload. Like all other
CFC gases, R12 and R502 were found to be harmful to the environment and were consequently prohibited.
These refrigerants were used together with mineral oils. A so called Spauschus reaction between oil and
refrigerant could consequently occur at high temperatures, which led to valve coking, especially at high
residual humidity.

14

P / T / X / D / N / F / S / G-Series
5.
DESIGN LIMITS

In order to secure a satisfying lifetime of the compressor, some design criteria for the appliances must
be fulfilled. Both the condensing temperature and the compressor temperature should be kept as low as
possible. This can be done by using well dimensioned condenser surfaces and by ensuring good ventilation
around the compressor under all operating conditions.

In order to protect the compressor against overload, the compressor must start and work properly through
pressure peaks obtained in the highest ambient temperature and lowest working voltage. These limitations
ensure a protection of valves, gaskets, oil, and motor insulation. Refrigerants R134a, R404A or R507 used
today need improved oils. They are only used in connection with special quality polyester oils.

Because of these new oil types and the application of the above mentioned refrigerants there is – in practice
– no longer any danger of valve coking.
Restrictions on condensing and motor temperatures are now set to protect the motor and thus increase its
life.

For the application of Secop compressors in household and commercial refrigeration using the available
refrigerants, we recommend the following rules to be observed:

5.1 Coil temperature must not exceed 125°C during continuous operation.
Coil temperature
For limited periods of time, e.g. during compressor start up or in the case of short load peaks, the
temperature should not exceed 135°C.

For commercial refrigeration with R134a the same limits as for household refrigeration apply.

However, fan cooling of the compressor is recommended.

5.2 When using R600a or R134a the condensing temperature during continuous operation must not exceed 60°C.
Condensing temperature During limited load peaks the temperature must not exceed 70°C. In commercial refrigeration using R404A
and R507 the condensing temperature limit is 48°C during continuous operation and 58°C in the case of load
peaks. All CL and DL compressors are fan cooled.

15

P / T / X / D / N / F / S / G-Series
6.
ELECTRICAL EQUIPMENT /
MOTOR SYSTEMS

The compressors are equipped with a single phase AC motor. The electrical equipment of Secop AC
compressor series P, T, D, N, F, S and G (electrics with relay, starting device, capacitor, cord relief and
cover) is classified as "normal tight" (IP20). The motor protector is built into the motor (winding protector).
Exceptions include compressors with the denominations TF/TT and NF/NT and some SCs. Earth connections
are located on the bracket around the current lead in of the compressor.
No attempt must be made to start the compressor without a complete starting device.

R134a: With some exceptions these compressors are designed with universal motors which means that
they can obtain a high (HST) or low starting torque (LST) depending on the external electrical
equipment used.

R600: Nearly all compressors for R600a are designed only for use with Low Starting Torque (LST).

R290: All compressors for R290 are designed for use with Low Starting Torque (LST) or
High Starting Torque (HST).

R404A/R507 All compressors for R404A/R507 and R407C are designed only for use with
and R407C: High Starting Torque (HST).

6.1 Compressors with the motor type Resistant Start Induction Run (RSIR) have a starting device for Low
LST (RSIR) Starting Torque (LST). The design of the electrical equipment depends on the actual compressor design. The
following designs of starting devices exist:

a) PTC + cord relief + cover, the motor protector is built into the motor (winding protector),

b) Relay housing incl. motor protector + cord relief + cover (alternative: terminal board with cord relief)

The PTC starting device requires pressure equalization before each start. This starting device is normally
used in well designed refrigerating systems with capillary tube as throttling device. The PTC needs a
compressor standstill period of 5 minutes to cool down before each start.

6.2 Compressors with the motor type Resistant Start Capacitor Run (RSCR) have a starting device for Low
LST (RSCR) Starting Torque (LST). This starting device consists of a PTC and a run capacitor.
The PTC starting device requires pressure equalization before each start. This starting device is normally
used in well designed refrigerating systems with capillary tube as throttling device.
The PTC needs a compressor standstill period of 5 minutes to cool down before each start.

6.3 Compressors with the motor type Capacitor Start Run (CSR) have a starting device for High Starting Torque
HST (CSR) (HST). The following designs of starting devices exist:

a) Relay + starting capacitor + run capacitor + terminal board + cord relief + cover

b) Relay + starting capacitor (with bracket) + run capacitor + cover/ protector/ protector holder (parts of
compressor), used for compressors which have an external protector.

The starting capacitor is designed for short time cut in. “1.7% ED”, which is stamped on the starting
capacitor, means for instance max. 10 cut ins per hour each with a duration of 6 seconds.

16

P / T / X / D / N / F / S / G-Series
6.4 Compressors with the motor type Capacitor Start Induction Run (CSIR) have a starting device for High
HST (CSIR) Starting Torque (HST). This starting device consists of a starting relay and a starting capacitor. The following
designs of starting devices exist:

a) Relay + starting capacitor + cord relief + cover

b) Relay housing including motor protector + starting capacitor + cord relief (2x)

c) Relay + starting capacitor (with bracket) + cover/ protector/ protector holder (parts of the compressor),
used for compressors which have an external protector.

The starting device requires no pressure equalization before each start and is normally used in refrigerating
systems with expansion valve as throttling device or in capillary tube systems where pressure equalizing is
not obtained during standstill periods.

The starting capacitor is designed for short time cut in. “1.7% ED”, which is stamped on the starting
capacitor, means for instance max. 10 cut ins per hour each with duration of 6 seconds (normally shorter
than 1 sec).

6.5 The electrical equipment is equipped with connectors depending on the ordered code number,
Connections
Starting relays: 6.3 mm spade connectors only
PTCs: 6.3 or 4.8mm spade connectors and screws

The power supply must be connected as shown in the wiring diagrams for the chosen electrical equipment
given in the actual datasheets.

6.6 The compressors have been approved in respect of safety by testing authorities in the majority of Western
Approvals European countries. Actual standards to which the compressors have been approved are specified in the
individual data sheets. Approval markings appear on the compressor type labels.

Most compressors which are capable of running at 60Hz


have been approved in respect of safety by testing authority .
UL.
UL approval markings appear on a separate approval mark
label.

Actual standards to which the compressors have been


approved are specified in the individual data sheets.

Note:
To fulfil the requirements of EN 60335-2-34
the protection screen 103N0476 must be
applied to the PTC starting device.

17

P / T / X / D / N / F / S / G-Series
6.7 Introduction
ePTC The asynchronous motor of a single phase AC powered compressor has two windings, a main and an
auxiliary winding. The auxiliary winding is powered high at start by means of a starting device, then powered
down, often still utilized continuously by means of a run capacitor. The starting device of our standard PTC
starters is a “Positive Temperature Coefficient” resistor, PTC. When heated up during the start phase, the
PTC almost cuts off the current to the auxiliary winding, leaving only enough current to keep itself heated to
this closing level. The associated heat loss amounts to approximately 2.5 W. With the ePTC this loss can be
reduced down to approximately 0.4 W by an extra electronic circuit.

Features Technical data


The electronic design of the starting device Electronically controlled PTC (version E-2)
offers some strong features such as: can alternatively be used for
• Compressor restart possible after a few P / T / D / N / F / S - Series
seconds. Only a very short cooling time is 103N0050 (25 Ohm)
necessary due to the electronic design. Code number 103N0058 (5 Ohm)
103N0055 (38 Ohm)
• Operational wattage loss reduced by 2 watt
• PTC protection screen not needed Nominal supply voltage 220 - 240 V, 50/60 Hz 115 V, 60 Hz
(surface temp. < 82 °C) Minimal supply voltage 187 V 90 V
• Temperature resistant up to min. +60 °C Maximal supply voltage 254 V 140 V
Power consumption approx. 0.4 W (after 2 s) approx. 0.5 W (after 2 s)
Functional description Spade connectors 4.8 mm 6.3 mm
The main component of the ePTC is the Cables temperature resistant up to min. +60 °C
same PTC pill like in other 220-240V
Run capacitor optional
103N…. Secop PTC starters. Thus the start
of the compressor motor is performed in from 0 °C to 50 °C during operation
Ambient temperatures
the same way. In standard PTC starters the from -20 °C to 70 °C during transport
>2 W energy loss to keep the PTC heated Enclosure IP 00
during compressor operation are not PTC protection screen not needed (surface temp. < 82 °C)
avoidable. In the ePTC a small electronic
circuit cuts off the current through the PTC a short time after start and thus reduces the energy loss down
to an approx 0.4W. The switch used is a Triac, an electronic AC switch, controlled by a timer circuit. As the
timer circuit has a short reset time and the main PTC cools down during compressor operation, the full start
torque will be available after approx 6 seconds compressor off time. However, if it is a LST starting device,
full pressure equalization is needed before start.

Connection & Terminals


The wiring diagram shows how to make the connections. The two screw terminals marked N and L are for
supply voltage. The spade on the L terminal and the spade marked C are for the thermostat. The spade
marked S at the top right position is internally connected to the start (or auxiliary) fusite terminal. This
spade together with N is used for a run capacitor. The spade marked N at the top left position is internally
connected to the neutral screw terminal. The spade marked C at the bottom position is internally connected
to the common fusite terminal. On the rear side of the ePTC starter there are three holes. The hole in
the bottom is for the common fusite terminal on the compressor. The top left hole is for the start fusite
terminal and the top right hole is for the main fusite terminal. The ePTC starter is mounted with the C spade
downwards.

EMC optimised ePTC versions (“E-2“)


Starting second quarter 2012 Secop has shipped EMC optimised ePTC versions (“E-2“). An added “gate cap” filter
on the PCB ensures improved Electromagnetic Compatibility (EMC). All other components remain unchanged.

6.8 A run capacitor holder is available for the “Energy optimized” and
Run capacitor holder “High Energy optimized” compressor range. This optional part is
fixed to the run capacitor for 220V directly and earth connected
on the compressor shell, concentrating all electrical accessories
on the compressor. This will save space in the machine
compartment. See drawing four mounting seequence.

Code numbers:
run capacitor holder 117-0300
screw M4 x 8 PZD 2 117-0301

18

P / T / X / D / N / F / S / G-Series
6.9 Code No. Capacity Voltage Stamping Bleeder Mount Compressor Approvals Supplier
Survey of starting [µF] [V] IEC Resistor Series L / D [mm]
capacitors 220V AB 1.7% ED KEMET / NGM
117U5012 125 220 no A SC VDE / CQC
300V AB 0.1% ED 121/39 95/39
220V AB 1.7% ED KEMET / NGM
117U5014 60 220 no A PL, TL VDE / CQC
300V AB 0.1% ED 95/39
220V AB 1.7% ED KEMET / NGM
117U5015 80 220 no A FR, NL VDE
300V AB 0.1% ED 95/39
220V AB 1.7% ED KEMET / NGM
117U5017 80 220 no A SC VDE / CQC
300V AB 0.1% ED 95/39
220V AB 1.7% ED KEMET / NGM
117U5018 125 220 no A NF, NL VDE / CQC
300V AB 0.1% ED 121/39 95/39
125V AB 1.7% ED KEMET / NGM
117U5022 320 115 no A NF, TFS CQC
165V AB 0.1% ED 80/39
125V AB 1.7% ED TL, TLS, KEMET / NGM
117U5023 240 115 no A CQC
165V AB 0.1% ED SC 80/39
125V AB 1.7% ED FR, NF, KEMET / NGM
117U5025 280 115 no A CQC
165V AB 0.1% ED TF, TFS 80/39
125V AB 1.7% ED KEMET / NGM
117U5028 410 115 no A NF CQC
165V AB 0.1% ED 95/39
125V AB 1.7% ED KEMET / NGM
117U5035 125 115 yes A NL, TL CQC
165V AB 0.1% ED 95/39
125V AB 1.7% ED KEMET / NGM
117U5040 320 115 no B FF CQC
165V AB 0.1% ED 95/39
125V AB 1.7% ED KEMET / NGM
117U5041 280 115 no B FF CQC
165V AB 0.1% ED 95/39
125V AB 1.7% ED KEMET / NGM
117U5042 410 115 no B SC CQC
165V AB 0.1% ED 95/39
125V AB 1.7% ED KEMET / NGM
117U5043 410 115 yes1 B SC CQC
165V AB 0.1% ED 95/39

Note:
1
for use with run capacitor

6.10 Code No. Capacity Voltage Frequency Connectors Compressor Approvals Drawing
Survey of run capacitors [µF] [V] [Hz] [mm] | type type
117-7111 5.0 430 50/60 6.3 | F SC VDE
117-7112 10.0 430 50/60 6.3 | F SC VDE
117-7114 23.5 190 60 6.3 | S SC UL
117-7117 4.0 320 50/60 6.3 | S NL/TL VDE
117-7118 15.0 190 60 6.3 | S NL/TL UL
117-7119 4.0 320 50/60 4.8 | S NL/TL VDE
117-7120 15.0 190 60 4.8 | S NL UL
117-7121 10.0 430 60 6.3 | F SC UL
117-7123 4.0 320 50/60 4.8 | S NL/TL VDE
117-7126 12.0 190 60 6.3 | S NL UL
117-7127 15.0 430 60 6.3 | F SC UL
117-7129 5.0 320 50/60 4.8 | S NL VDE
117-7130 5.0 320 50/60 6.3 | S NL VDE
117-7131 3.0 320 50/60 6.3 | S NL/TL VDE
117-7132 3.0 320 50/60 4.8 | S NL/TL VDE
117-7133 23.5 190 60 6.3 | F SC UL
117-7134 15.0 450 50/60 6.3 | F GS VDE
117-7135 20.0 330 50/60 6.3 | F GS VDE
117-7136 2.0 320 50/60 4.8 | S NL/TL VDE
117-7137 15.0 430 60 6.3 | F SC UL
117-7138 20.0 330 60 6.3 | F GS UL
117-7139 2.5 320 50/60 4.8 | S NL/TL VDE
117-7140 3.5 320 50/60 4.8 | S NL/TL VDE

19

P / T / X / D / N / F / S / G-Series
LST - RSIR LST - RSCR
PL-DLE TL/TLES/TLS/TLY - NL/NLE - FR PLE - DLE/DLX/DLY

HST - CSIR LST - RSCR


PL - DLE TL/TLES/TLS - NL/NLE - FR TLES/TLS/TLX/TLY - NLE/NLU/NLX/NLY

Legend HST - CSIR


SC Twin

a1: PTC starting device


a2: Starting relay
a3: Starting device
b: Cover
b1: Clamp (part of compressor)
b2: Gasket (part of compressor)
c: Starting capacitor
d: Cord relief
e: Run capacitor
f: Protector
g: Protection screen for PTC
h: Holder

20

P / T / X / D / N / F / S / G-Series
LST - RSIR
TF/TFS - NF - FF TT TF - NF - FF

HST - CSIR
TFS - NF - FF FF TF - NF - FF

HST - CSR LST - RSCR


SC Twin TTE/TTY - NTX/NTY

21

P / T / X / D / N / F / S / G-Series
HST - CSIR
SC SC SC

LST - RSIR HST - CSR


SC SC SC

HST - CSR
SC SC (kit) GS

22

P / T / X / D / N / F / S / G-Series
HST - Electronic Unit 105N4220/105N4210/105N4212 (variable speed) LST / HST - 105N50xx Series Controller (variable speed)
BD150F/NLV XV - drawings shows electronic unit 105N5022 (attached)

LST - 105N46xx Series Controller (variable speed)


SLV

Mains red
R L 1 blue
R L 2 yellow
R L 3 black
R L 4 grey
R L 5 green
S3 red
S4 blue
S5 yellow
S6 black
DI grey
Display green

6.11 Full load operation is extremely rare in most cooling applications, restricted to a few days per year. That is why
Electronic units / Secop builds variable speed control into the BD/NLV/SLV and X-Series. This unique technology makes capacity
Controllers automatically adapt to your actual requirement.
(variable speed) The compressor runs at low speed most of the time, minimizing energy consumption. On top of this, system
efficiency is greatly improved thanks to reduced loss when less heat is transferred via the evaporator and con-
denser. Altogether, substantial energy savings can be obtained.
The variable speed compressor motors are electronically controlled. No attemp must be made to start the
compressor without a complete electronic unit, as specified in the data sheet for the compressor type in
question.
The electronic unit has a built-in overload protection as well as thermal protection. In case of activation of
this protection the electronic unit will protect the compressor motor as well as itself. When the protection
has been activated, the electronic unit automatically will restart the compressor after a certain time.
The electronic unit provides the compressor with High Starting Torque (HST) which means that a pressure-
equalizeation of the system before start is not necessary.
The compressors are equipped with permanent magnet rotors (PM motor) and 3 identical stator windings.
The electronic unit is mounted directly on the compressor and controls the PM motor.
Connecting the motor to AC mains, by fault, will damage the magnets and lead to drastically reduced
efficiency, or even non functioning.
For further information on which starting device to use on individual compressors, please refer to the actual
datasheets (some compressors have limitations for either LST or HST). and to our "Operationg Instructions"
and "Instructions".
For further information on the variable speed technology please refer to our Whitepaper "Advantages of
adaptable Capacity".

23

P / T / X / D / N / F / S / G-Series
7.
IP44 EQUIPMENT FOR
SC COMPRESSORS

As the expansion of refrigeration and air condition-


ing technology into new application areas is ongo-
ing, traditional applications face an increasing use
worldwide.

Consequently, refrigeration equipment is more often


operated under extreme conditions and hermetic
compressors have to meet the resulting require-
ments.
One of these requirements is the adequate protec-
tion of the compressor and its outside electrical
parts against moisture and water.

Secop now offers special accessories, which provide


a better IP protection class for a major part of the
SC compressor models.
All SC models for 220-240V/50Hz or 208-230V/60Hz
with CSIR motor can be IP upgraded.

The equipment consists of one additional part, the


so called “back cover”, and an upgraded starting
capacitor (Fig.1 ).
When using this equipment, the protection class is Fig.1 Back cover 103N2020 + starting capacitor
117U5117
increased to IP44, i.e. the compressor and its elec-
trical parts are splash-proof (Fig.2 ).

Code number Description

103N2020 Back cover


IP44 starting
117U5117*
capacitor 80µF
*replaces standard capacitor 117U5017

This equipment may be used with VDE approved


compressors.
Starting capacitors with other capacities can be
upgraded on demand.

Fig.2 IP44 Equiment mounted on a SC compressor

24

P / T / X / D / N / F / S / G-Series
8.
TWIN COMPRESSORS

The twin version consists of two SC compressors mounted on a common base plate. The two compressors
are joined by an oil-equalizing tube and also have an intake manifold with screw connector for a service valve
or a solder connector (these parts are supplied as accessories, please refer to data sheets for more info).

Each twin compressor is supplied with two sets of electrical equipment and mounting accessories.

To ensure optimum starting


characteristics and the smallest
possible mains load we recommend
that the compressors be equipped
with a time delay relay for start
of the second compressor. Twin
compressors can operate with
capacity regulation depending on
the controls used.

Depending on the motor type


(CSR/CSIR) all accessories needed
are illustrated in the drawing below.

Accessories for SC Twin


SC10/10, SC12/12 and SC15/15:
Service valve for 12 mm tube 118-7350
Solder connector for 12 mm tube 104B0584

SC18/18 and SC21/21:


Service valve for 16mm tube 118-7351
Solder connector for 16mm tube 118-7405

SC10/10, SC12/12, SC15/15, SC18/18 and SC21/21:


Seal ring for service valve and solder connector 118-3638
Time delay relay 117N0001
Check valve (to be used with time – delay relay) 020-1014

25

P / T / X / D / N / F / S / G-Series
9.
MOISTURE AND IMPURITIES

The compressors are dried to a maximum moisture content of 60 to 75 mg depending on the compressor
size. The maximum impurity content is 40 to 50 mg depending on the compressor size.

Secop compressors leave the factories with a moisture load less or equal 125 ppm. This ppm rate includes
a safety factor for a storing time up to one year or longer. In addiction of storing time and storing conditions
the moisture level will increase. A level between 200 and 250 ppm in general is not critical and will not harm
the compressors or systems, where the compressors will be implemented.

Measurement method

Test parameters demand


Conditioning 24 h, room temperature
Condition of compressor charged with oil
Measurement temperature room temperature
Measurement time 1-2 min
Medium dew point
Measurement cell electrical hydrometer
Demand max.125 ppm H2O

With this measurement method, the total moisture in the air volume will be measured. The water, which
is fixed in the plastic structure and the oil, will only be measured indirectly. Within 24 hours equilibrium
between the humidity contents of the air and compressor parts is reached.
The limit of 125 ppm is very low, if we consider that the surrounding air contains approx. 8000 ppm at 22°C
and a relative humidity load of 40 %.

26

P / T / X / D / N / F / S / G-Series
10.
CONDITION AT DELIVERY/
WARNINGS

The compressors are delivered without mounted starting devices on pallets. The standard pack can be
stacked and is intended for transport by forklift truck. The bottom pallet has the dimensions 1144 x 800mm.

Quantities per pallets are specified in the individual data sheets.


Electrical equipment is packed in separate boxes.

The most important performance controls carried out during manufacturing are,
• A high potential insulation test with 1650V for 1 second
• Pumping capacity
• Tightness of discharge side and discharge valve
• Tightness of compressor housing
• Check of the right oil charge
• Noise test

The compressors are supplied with sealed connectors and the sealing should not be removed before the
system assembly takes place. (max. 15 minutes with open connectors).

The compressors are supplied charged with dried and degassed oil, which is normally sufficient for the
lifetime of the compressor. The refrigeration systems and the system components must be dimensioned in
such a way that the oil can be lead back continuously to the compressor housing without accumulating in
the system, e.g. without the oil pockets and with sufficient gas velocity. The compressors use polyolester
or mineral oils and are approved only for these oils and for the refrigerant to be used. The oil charge is
specified in the individual data sheets.

A high potential test with 1650V for 1 second is carried out on all compressors before delivery.
No high potential test or start tests must be carried out while the compressor is under vacuum. No attempt
must be made to start the compressor without a complete starting device.

Allow the compressor to reach a temperature above 10°C before starting the first time in order to avoid
starting problems.

Anti freeze agents must not be used in the compressors as such agents are damaging to several of the
materials used. In particular, the ethyl or methyl alcohol contents of such anti freeze agents have a
destructive effect on the synthetic motor insulation

27

P / T / X / D / N / F / S / G-Series
11.
MAX. REFRIGERANT CHARGE

R404A/R507 and R407C Only the refrigerant amount which is necessary for the system to function must be charged. The refrigerant
R134a amount may be critical, regarding oil foaming and liquid hammer after long standstill periods. Because of
115 V / 220-240 V this, limitations of refrigerant charges have been introduced.

SC Twin: max. 2200g


SC: max. 1300g
FR, FF: max. 900g
TL, TF, TT: max. 400g
NL, NF, NT: max. 400g

If the permissible limit of refrigerant charge stated in the compressor data sheet is exceeded the oil will
foam in the compressor after a cold start and may result in a damaged valve system in the compressor. The
refrigerant charge must never exceed the amount that can be contained in the condenser side of the system.

If these limitations cannot be complied with, the risk may be reduced if a crankcase heater is properly used
or if a pump down system is established.

Max. refrigerant charge


Compressor type
R134a R600a R290 R404A
P 300 g 120 g - -
T 400 g* 150 g 150 g 600 g
X - 150 g - -
D - 150 g 150 g -
TL-G 600 g - - -
N 400 g* 150 g 150 g 400 g
F 900 g - - 850 g
S 1300 g - 150 g 1300 g
G 2000 g - - 2000 g
SC Twin 2200 g - - 2200 g
* Single types with higher limits available, see Data Sheets
Please refer to the compressor data sheets, as the maximum refrigerant charge may deviate on single types
from the statements in the form. The maximum charge of 150g for R600a and R290 is an upper safety limit of
the appliance standards, whereas the other weights are stated to avoid liquid hammer.

R290 / R600a According to the European Standard EN 60335-2-24 or draft IEC 60335-2-89, which must be complied with,
the refrigerant charge must not exceed 150g.

Commercially available R600a and R290 must not be used because the fuel grades of these products are
of a variable composition. These products may also contain impurities which could significantly reduce the
reliability and performance of the system and lead to premature failure. All Secop compressors for R600a
and R290 are released for a base purity of 97% or better. Impurity limits shall comply with DIN 8960 of 1998
(extended version of ISO 916).

All users of refrigerant R600a should refer to the chemical data safety sheets for full information on the safe
handling of R600a and R290.

In general the charge of R600a or R290 is approximately 40-50% by weight than that for HFC.

The refrigerant charge must never be too large to be contained on the condenser side of the refrigeration
system. Only the refrigerant amount which is necessary for the system to function must be charged.

28

P / T / X / D / N / F / S / G-Series
12.
CONVERSIONS

From R12 to alterntaive As long as new or recycled R12 refrigerant is available this should be used. It is impossible to provide R12
refrigerant and illegal to use it. It should be thoroughly considered whether repair is worth while. It is hardly worth
repairing old small refrigeration systems if it involves replacement of the compressor. Another consideration
is use of an alternative refrigerant instead of R12.

From R12 to R134a Normally, the capillary tube shall be adjusted at low evaporating temperatures. Compared to an optimized
R12 system with the same evaporator capacity, the R134a system must have an increased resistance defined
as approx. 10% less N² flow at 10 bar inlet pressure.
The same size of capillary tube as used for R12 can be used at high evaporating temperatures.
• A drier with 3A desiccant of molecular sieves must always be used.
• Rules for dryness and cleanliness of system components (DIN 8964) are transferred to R134a systems.
• The system components must not contain mineral oil or greasy substances.
• The compressors must be soldered into the system no later than 15 minutes after the connector seals
have been removed.
• The same evacuation procedure as for R12 systems must be used.
• Max. 1% non – condensable gases.
• The system must not contain any chlorine.
• The charging equipment must only be used for R134a.
• If the same vacuum pump is to be used for R12 and R134a systems, special Ester oil must be used in
agreement with the pump supplier.

From R502 / R22 or Normally, the same system components can be used as were used with R22. However, an adjustment of the
R404/R507 to R290 charge must be made. Especially the system design must follow safety standards as EN/ IEC 60335-2-24 or
IEC 60335-2-89, EN 378 or national standards.
• A drier with 3A desiccant of molecular sieves or a hardcore drier compatible with R290 must always be
used.
• Rules for dryness and cleanliness of system components (DIN 8964) are transferred to R290 systems.
• The compressors must be soldered into the system no later than 15 minutes after the connecter seals
have been removed.
• The same evacuation procedure as for R22 / R502 / R404A systems must be used.
• Max. 1% non condensable gases.
• The system must not contain chlorine.

From R502 / R22 to Normally, the same system components can be used as were used with R502. However, an adjustment of
R404A/R507 or R407C the charge must be made.
• A drier with 3A desiccant of Molecular Sieves or a hard core drier compatible with R404A must always be
used.
• Rules for dryness and cleanliness of system components (DIN 8964) are transferred to R404A systems.
• The system components must not contain mineral oil or greasy substances.
• The compressors must be soldered into the system no later than 15 minutes after the connector seals
have been removed.
• The same evacuation procedure as for R502 / R22 systems must be used.
• Max. 1% non condensable gases.
• The system must not contain any chlorine.
• The charging equipment must only be used for R404A/R507 respectively R407C.

29

P / T / X / D / N / F / S / G-Series
13.
MOUNTING

Soldering problems caused by oil in the connectors can


be avoided by placing the compressor on its base plate
some time before soldering it into the system.
The compressor must never be placed upside down
when mounting the rubber grommets in the base plate.
Instead place the compressor on its side with
the connectors upwards.
The system should be closed within 15 minutes to avoid
moisture and dirt penetration.

Tightening torque for M6 bolt joint mountings should be


5 Nm ± 0,5 (hand-tight).

13.1 The positions of connectors are found in the sketches. C


Connector positions means suction and must always be connected to the suction line. E means discharge and must be connected
to the discharge line. D means process and is used for processing the system.

Most Secop compressors are equipped with tube connectors of thick-walled, copper-plated steel tube which
have a solderability which comes up to that of conventional copper connectors.
The connectors are welded into the compressor housing and weldings cannot be damaged by overheating
during soldering.
These copper-plated steel connectors have an aluminium cap sealing which gives a tight sealing. The seal-
ing secures that the compressors have not been opened after leaving Secop's production lines. In addition to
that, the sealing makes a protecting charge of nitrogen superfluous.

Compressor with copper connectors and are sealed with rubber plugs.
Oil cooler tubes are made of copper and the connectors are sealed with rubber plugs too.

30

P / T / X / D / N / F / S / G-Series
14.
MOUNTING ACCESSORIES

Mounting Code Bolt / pin Comp. Type of packaging Compressor series Parts
number dimension base hole list
Bolt joint 118-1917 M6 metric 16 mm Single pack for one compressor BD- / P- / T- / X- / D- / N- / F- / S-Series I
Bolt joint 118-1918 M6 metric 16 mm Industrial pack in any quantity BD- / P- / T- / X- / D- / N- / F- / S-Series I

Bolt joint 107B9150 M8 metric 19 mm Single pack for one compressor G-Series II

Bolt joint 118-1946 1/4 inch 16 mm Single pack for one compressor BD- / P- / T- / X- / D- / N- / F- / S-Series III
Bolt joint 118-1949 1/4 inch 19 mm Single pack for one compressor all with 19 mm base holes (except G-Series) IV

Snap-on 118-1947 Ø 7.3 mm 16 mm Single pack for one compressor BD- / P- / T- / X- / D- / N- / F- / S-Series V
Snap-on 118-1919 Ø 7.3 mm 16 mm Industrial pack in any quantity BD- / P- / T- / X- / D- / N- / F- / S-Series V

Parts list (4 pcs. per compressor needed) Symbol drawings


Sleeve Ø 8 mm x 6.4 mm x 0.8 mm 112-2052
Washer Ø 20 mm x Ø 6.7 mm x 1 mm 112-2053
I Bolt M6 x 25 mm 681X1130
Nut M6 118-3659
Rubber grommet 16 mm 118-3661
Sleeve Ø 11 mm x 8.6 mm x 1.2 mm 107B9152
Washer Ø 20 mm x Ø 8.8 mm x 1.2 mm 107B9155
II Bolt M8 x 40 mm 107B9153
Nut M8 107B9154
Rubber grommet 19 mm 107B9151
Sleeve Ø 8.3 mm x 6.7 mm x 0,8 mm 112-2088
Washer Ø 20 mm x Ø 6.7 mm x 1 mm 112-2053
III Bolt 1/4 x 1 inch, 20 UNC 119-3002
Nut 1/4 inch, 20 UNC 119-3031
Rubber grommet 16 mm 118-3661
Sleeve Ø 9.5 mm x 7.9 mm x 0,8 mm 112-2085
Washer Ø 20 mm x Ø 6.7 mm x 1 mm 112-2053
IV Bolt 1/4 x 1 1/4 inch, 20 UNC 119-3002
Nut 1/4 inch, 20 UNC 119-3031
Rubber grommet 19 mm 118-3666
Steel pin 118-3586
Washer Ø 21 x Ø 8.1 mm x 0.9 mm 118-3588
V
Clip 118-3585
Rubber Grommet 16 mm 118-3661

31

P / T / X / D / N / F / S / G-Series
14.
SHIPMENT POSITIONS
OF REFRIGERATION APPLIANCES

Shipment of refrigeration appliances in horizontal position

When refrigeration appliances are shipped in the normal vertical position, this will normally not cause
any damage to the compressor. If transported in horizontal position, the compressor must be oriented as
shown in the table on the next page to prevent the accumulation of oil in the muffler and subsequent risk of
damage. It is important to note that the compressor must be securely fastened and well supported during
transportation.

Refrigeration appliances can be safely transported in horizontal position:

• with trucks on roads and motorways in good condition


• by ship in containers
• on railways in good condition

Compressors
Shipment positions of refrigeration appliances - Position X must not be used

Connectors up Electrical lead-in up Connectors down Electrical lead-in down Base plate up

X - Series

D - Series

32

P / T / X / D / N / F / S / G-Series
Compressors
Shipment positions of refrigeration appliances - Position X must not be used

Connectors up Electrical lead-in up Connectors down Electrical lead-in down Base plate up

P - Series

T - Series

N - Series

F - Series

S - Series

G - Series

33

P / T / X / D / N / F / S / G-Series
SECOP HERMETIC RECIPROCATING
COMPRESSORS MADE IN AUSTRIA

Secop Austria GmbH was already established in 1982 as “Verdichter Oe” in Fürstenfeld, Austria. The production
site has several years of experience in developing high performing compressor solutions, mainly for household
refrigeration appliances. The highly advanced manufacturing technology allows to manufacture products with the
highest quality and performance standards and offer reliable efficiency in all areas. The Know-How and expertise
of the innovative research and development team along with the close cooperation with market leading customers
results in product innovation that enhances customer values and standards.

DELTA KAPPA

R600a (typelabel stripe colour: Red)


Refrigerant Typelabel colour
Chemical formula: C4H10

Voltage & frequency 220-240 V, 50Hz Yellow


Basic types KAPPA, DELTA

34

KAPPA / DELTA
GENERAL PRODUCT DOCUMENTATION
KAPPA

Table of Content

1 Compressor denomination / Label...................................................................................................................................... 36


2 Motor types / Approvals........................................................................................................................................................ 37
2.1 Motor types................................................................................................................................................................... 37
2.2 Certificate references................................................................................................................................................... 37
2.2.1 HXK...................................................................................................................................................................... 37
2.2.2 HKK...................................................................................................................................................................... 37
2.2.3 HTK...................................................................................................................................................................... 37
2.2.4 HMK..................................................................................................................................................................... 37
3 Delivery conditions / Application conditions........................................................................................................................ 38
3.1 Delivery conditions....................................................................................................................................................... 38
3.2 Application conditions.................................................................................................................................................. 38
3.2.1 Oil transport of the compressor in the refrigeration circuit.............................................................................. 38
4 Drawings ............................................................................................................................................................................. 39
4.1 3D sketch, mechanical data sketch............................................................................................................................. 39
4.2 Outline dimensions with short service tube................................................................................................................ 40
4.3 Outline dimensions with long service tube.................................................................................................................. 41
5 Transport, packing, palletization.......................................................................................................................................... 42
5.1 Recommended transport positions when fitted into appliances................................................................................ 42
5.2 Packaging and palletization......................................................................................................................................... 42
5.2.1 Packaging type, pallet data................................................................................................................................. 42
5.2.2 Transport............................................................................................................................................................. 42
5.2.3 Warehouse storing.............................................................................................................................................. 43
5.2.4 Recycling of compressors................................................................................................................................... 43

35

KAPPA / DELTA
1.
COMPRESSOR DENOMINATION/
LABEL

1 2 3 4 5 group
H X K 12 AA example

Group#5: Voltage Range


"AA" for 187-264 V~ 50 Hz (nominal 220-240 V~ 50 Hz)
"AT" for 170-264 V~ 50 Hz (nominal 200-240 V~ 50 Hz)

Group#4: Key figure


which indicates displacement of compressor

Group#3: Platform
"K" for KAPPA

Group#2: Performance level "M, T, K, X, Z" (Medium Efficiency > Superior Efficiency)

Group#1: Refrigerant
"H" for R600a

Production date

8804
Compressor model Secop logo
1005 HKK12AA
Background: white MADE IN AUSTRIA
Electrical characteristics
Suction tube indication
a

220-240 V ~ 50 Hz
00

Variant code B SUCTION


R6

9 052 1234567 0 Check digit


Background: yellow TP Serial number
Pantone 137 Approval marks
Symbol and text: black Manufacturer &
Bar code version code

1005 HKK12AA
MADE IN AUSTRIA
a

220-240 V ~ 50 Hz
00

B SUCTION
R6

9 052 1234567 0
TP

36

KAPPA / DELTA
2.
MOTOR TYPES/
APPROVALS

2.1 Resistance start – inductive run


Motor types RSIR:
Start winding is interrupted after start-up by a PTC.
Resistance start – capacitive run
RSCR: For higher efficiency the auxiliary winding is supporting the main winding by a run
capacitor.
RSIR/RSCR: Depending on requirements motor can be used as RSIR or RSCR type.

2.2
Certificate references

2.2.1 VDE, (CE) EAC


HXK
Licence No. Licence No.
TC RU D-AT.AG27.B.00381
40023933 TC RU D-AT.Ag27.B.00382
TC RU D-AT.AG27.B.00383

2.2.2 VDE, (CE) EAC


HKK
Licence No. Licence No.
40010874 TC RU D-AT.AG27.B.00381
40031157 TC RU D-AT.AG27.B.00382
- TC RU D-AT.AG27.B.00383

2.2.3 VDE, (CE) EAC


HTK
Licence No. Licence No.
TC RU D-AT.AG27.B.00381
40003038
TC RU D-AT.AG27.B.00382

2.2.4 VDE, (CE) EAC


HMK Licence No. Licence No.
TC RU D-AT.AG27.B.00381
40016826
TC RU D-AT.AG27.B.00382

37

KAPPA / DELTA
3.
DELIVERY CONDITIONS/
APPLICATION CONDITIONS

3.1 Max. solid impurities (*) [mg] 30


Delivery conditions
Max. soluble impurities (*) [mg] 600
Max. total compressor water content (*) [mg] 100
(*) When delivered

3.2 Max. ambient temp.1 [°C] 43


Applications conditions
Max. steady discharge temp.2 [°C] 120
Max. peak discharge temp. 2, 5 [°C] 135
Max. steady condensing temp. 3 [°C] 60
Max. peak condensing temp. 3, 5 [°C] 70
Max. winding temp. 4 [°C] 130
1 ... static
2 ... measured on discharge tube, 50 mm from the schell
3 ... measured in the middle of condenser
4 ... calculated out of the measured difference of resistance
5 ... max. 5% life time

3.2.1 Average value of the transported oil in the refrigeration circuit:


Oil transport of the 2.5 g oil/kg R600a mass flow per hour.
compressor in the
refrigeration circuit Tolerance:
±2.5 g oil/kg R600a mass flow per hour.

38

KAPPA / DELTA
4.
DRAWINGS

4.1
3D sketch, mechanical
data sketch

39

KAPPA / DELTA
4.2
Outline dimensions with
short service tube

40

KAPPA / DELTA
4.3
Outline dimensions with
long service tube

41

KAPPA / DELTA
5.
TRANSPORT, PACKING, PALLETIZATION

5.1
Recommended transport
positions when fitted into
Upright Tubes down Terminal board down
appliances

5.2
Packing and palletization Compressors Pallet
Packing-type Layers Quantity per layer Size L×W
5.2.1 L×Q mm
Packing type, pallet data
4 80 5×4 = 20 1120×820
Wood-EPS *
One-Way 5 100 5×4 = 20 1120×820
packaging
Single
5 60 4×3 = 12 1120×820
packaging
More-Way 4 84 7×3 = 21 1200×800
ABS
packaging 5 105 7×3 = 21 1200×800
*Optional protection and reinforcement with cardboard-box and PE top foil.

5.2.2 Stacking height


Transport Packing-type Layers Number of pallets
Truck Container Train 1, 2
4 1 - -
Wood-EPS
5 1 - -
Wood-EPS + 4 1 - 1
cardboard-box 5 1 - 1
One-Way
packaging Wood-EPS + 4 1 2 1
cardboard-
box + 5 1 2 1
PE top foil
Single
5 1 1 -
packaging
More-way 4 2 - 1
ABS
packaging 5 1 - 1
1 Train transport according UIC-Codex 526-1. In sliding wall wagon with lockable bulkhead only;
2 Train loading according BT Band 2 Rail Cargo Austria, Loading guideline 100.1; Contact of pallet to bulk
head is mandatory; respectively the maximum distance of 45 mm has to be guaranteed. Maximum
weight of goods between bulk heads is 5 t.

42

KAPPA / DELTA
5.2.3 More-Way packaging
Warehouse storing One Way packaging max. 3 pallet layers – 3rd layer with offset.

8829

Attention: Single packaging one pallet layer only!

5.2.4 Oil and gas must be recycled separately. Afterwards the compressor must be removed from the refrigerator
Recycling of and has to be given to a scrap metal recycling unit.
compressors

43

KAPPA / DELTA
ACCESSORIES
KAPPA

Table of Content

1 Electrical components.......................................................................................................................................................... 45
1.1 Terminal board assembly............................................................................................................................................. 45
1.2 Outline with terminal board cover............................................................................................................................... 45
2 Electric terminal circuit diagram / Mounting accessories................................................................................................. 46
2.1 Standard frontal version............................................................................................................................................... 46
2.2 Standard........................................................................................................................................................................ 46
2.3 Optional......................................................................................................................................................................... 46
3 Evaporation tray.................................................................................................................................................................... 47
3.1 Dimension of evaporation tray .................................................................................................................................... 47
3.2 Outline dimension with evaporation tray..................................................................................................................... 47

44

KAPPA / DELTA
1.
ELECTRICAL COMPONENTS

1.1
Terminal board
assembly

1.2
Outline with terminal
board cover

45

KAPPA / DELTA
2.
ELECTRIC TERMINAL CIRCUIT DIAGRAM/
MOUNTING ACCESSORIES

2.1
Standard frontal version

2.2
Standard

2.3
Optional

46

KAPPA / DELTA
3.
EVAPORATION TRAY

3.1
Dimension of
evaporation tray

3.2
Outline dimension with
evaporation tray

47

KAPPA / DELTA
GENERAL PRODUCT DOCUMENTATION
DELTA

Table of Content

1 Compressor denomination / Label...................................................................................................................................... 49


2 Motor types / Approvals / Delivery conditions..................................................................................................................... 50
2.1 Motor types................................................................................................................................................................... 50
2.2 Certificate references................................................................................................................................................... 50
2.2.1 HXD...................................................................................................................................................................... 50
2.2.2 HTD...................................................................................................................................................................... 50
2.3 Delivery conditions....................................................................................................................................................... 50
3 Drawings............................................................................................................................................................................... 51
3.1 Outline dimensions and tubes..................................................................................................................................... 51
3.2 3D sketch, mechanical data sketch............................................................................................................................. 53
4 Transport, packing, palletization.......................................................................................................................................... 54
4.1 Recommended transport positions when fitted into appliances................................................................................ 54
4.2 Packaging and palletization......................................................................................................................................... 54
4.2.1 Packaging type, pallet data................................................................................................................................. 54
4.2.2 Transport............................................................................................................................................................. 54
4.2.3 Warehouse storing.............................................................................................................................................. 55
4.2.4 Recycling of compressors................................................................................................................................... 55
5 Electrical components / Electric terminal circuit diagram................................................................................................ 56
5.1 Terminal board assembly............................................................................................................................................. 56
5.2 Electric terminal circuit diagram................................................................................................................................. 56
6 Accessories........................................................................................................................................................................... 57
6.1 Adapter plate and compressor mounting.................................................................................................................... 57
6.1.1 Outline dimensions with adapter plate.............................................................................................................. 58
6.2 Plastic evaporation tray................................................................................................................................................ 58
6.2.1 Outline dimensions with plastic evaporation tray.............................................................................................. 58
7 Brazing and refrigerant charge............................................................................................................................................ 59

48

KAPPA / DELTA
1.
COMPRESSOR DENOMINATION/
LABEL

1 2 3 4 5 group
H X D 55 AA example

Group#5: Voltage range


"AA" for 187-264 V~ 50 Hz (nominal 220-240 V~ 50 Hz)

Group#4: Key figure


which indicates displacement of compressor

Group#3: Platform
"D" for DELTA

Group#2: Performance level "T, X, Z" (Top Efficiency > Superior Efficiency)

Group#1: Refrigerant
"H" for R600a

Approval marks

8817
Compressor model
Suction tube indication Production date

Electrical characteristics Secop logo


220-240 V ~ 50 Hz
HXD55AA Approval marks
a

S MADE IN AUSTRIA
00

F
TP
R6

0 001 00001234 0 1005


Background: white
Background: yellow
Manufacturer & Pantone 137
version code Symbol and text: black
Variant code Check digit
Serial number Bar code

220-240 V ~ 50 Hz
HXD55AA
a

S MADE IN AUSTRIA
00

F
TP
R6

0 001 00001234 0 1005

49

KAPPA / DELTA
2.
MOTOR TYPES/
APPROVALS/
DELIVERY CONDITIONS

2.1 Resistance start – inductive run


Motor types RSIR:
Start winding is interrupted after start-up by a PTC.
Resistance start – capacitive run
RSCR: For higher efficiency the auxiliary winding is supporting the main winding by a run
capacitor.
RSIR/RSCR: Depending on requirements motor can be used as RSIR or RSCR type.

2.2
Certificate references

2.2.1 VDE, (CE) EAC


HXD
Licence No. Licence No.
40029645 TC RU D-AT.AG27.B.00382

2.2.2
HTD VDE, (CE) EAC
Licence No. Licence No.
40030818 TC RU D-AT.AG27.B.00382

2.3 Max. solid impurities [mg] 30


Delivery conditions
Max. soluble impurities [mg] 600
Max. total compressor water content (*) [mg] 100

50

KAPPA / DELTA
3.
DRAWINGS

3.1
Outline dimensions
and tubes

t t

51

KAPPA / DELTA
3.1
Outline dimensions
and tubes

52

KAPPA / DELTA
3.2
3D sketch, mechanical Bracket
Clamping sleeve

8830
data sketch
Piston pin Cover pressed
Piston
Valve plate gasket
Suction valve
Valve plate
Discharge valve
Cylinder head gasket
Clamping element Conrod
Fixing element Roller Bearing

Crankcase
Crankshaft
Rotor
Oilpump
Stator screw
Direct suction element
Suction muffler
Discharge muffler
Plug casing assembled
Terminal fence
Capacitor

Hermetic Terminal
Board assembled
Stator assembled
Stator brackets
Suspension spring
Spring pins for shell

Discharge tube
Rubber grommet
Hermetic terminal
Suction tube Steel pin
Shell pressed Adapter plate
Service tube

53

KAPPA / DELTA
4.
TRANSPORT, PACKING, PALLETIZATION

4.1
Recommended transport
positions when fitted into
appliances Upright Tubes up Terminal board up

4.2 Compressors Pallet


Packing and palletization per layer Size L×W
Packing-type Layers Quantity
4.2.1 L×Q mm
Packing type, pallet data 6 168 7×4 = 28 1200×800×1100
EPS +
5 140 7×4 = 28 1200×800×946
PE top foil
One-Way 4 112 7×4 = 28 1200×800×792
packaging
EPS +
Cardboard-box 6 168 7×4 = 28 1200×800×1100
+ PE top foil

4.2.2 Stacking height


Transport Number of pallets
Packing-type Layers
Truck Container Train 1, 2
6 1 1 1
EPS +
5 1 1 1
PE top foil
One-Way 4 1 1 1
packaging
EPS +
Cardboard-box 6 1 2 1
+ PE top foil
1 Train transport according UIC-Codex 526-1. In sliding wall wagon with lockable bulkhead only;
2 Train loading according BT Band 2 Rail Cargo Austria, Loading guideline 100.1; Contact of pallet to bulk
head is mandatory; respectively the maximum distance of 45 mm has to be guaranteed. Maximum
weight of goods between bulk heads is 5 t.

54

KAPPA / DELTA
4.2.3
Warehouse storing

8829

Attention: Single packaging one pallet layer only!

4.2.4
Recycling of Oil and gas must be recycled separately. Afterwards the compressor must be removed from the refrigerator
compressors and has to be given to a scrap metal recycling unit.

55

KAPPA / DELTA
5.
ELECTRICAL COMPONENTS/
ELECTRIC TERMINAL CIRCUIT DIAGRAM

5.1
Terminal board
assembly

5.2
Electric terminal circuit
diagram

56

KAPPA / DELTA
6.
ACCESSORIES

6.1
Adapter plate

Compressor mounting

Step 1

Put down compressor in front of key holes.

Step 2

Click in first foot with linear movement.

Step 3

Click in foot 2 and 3 with rotary movement.

57

KAPPA / DELTA
6.1.1
Outline dimensions with
adapter plate

6.2
Plastic evaporation tray

6.2.1
Outline dimensions with
plastic evaporation tray

58

KAPPA / DELTA
7.
BRAZING AND REFRIGERANT CHARGE

Í
Use brazing protection shield Do not reduce tube length

Max. 10 sec.
Í
Factory/OEM: Factory/OEM:
Stop brazing after max. 10 sec to allow Avoid heating tube root and direct flame on
the tube to cool down compressor surface
Service/Repair: Service/Repair:
Use LokRing® tooling Use LokRing® tooling

Gas quantity We recommend using roughly 10% less refrigerant versus Kappa to achieve optimum energy consumption.

59

KAPPA / DELTA
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R134a
220-240 V | 50 Hz

P-Series............................................................................................................................................................62-63
T-Series............................................................................................................................................................64-65
N-Series............................................................................................................................................................66-69
F-Series............................................................................................................................................................70-71
S-Series............................................................................................................................................................72-75
G-Series............................................................................................................................................................76-77

Chemical formula Starting devices


CH2FCF3 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Blue The PTC starting device requires 5 minutes cooling before
Typelabel colour: Yellow each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

60
61
R134a • 220-240 V • 50 Hz • P-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
PL20F 101G0100 MBP 36 65 83 16 0.38 50 0.87 45 81 103
PL35F 101G0202 MBP 60 101 125 32 0.64 79 1.10 75 125 156
PL50F 101G0220 LBP 14 74 40 0.67 95 1.11 18 92
PL50F 101G0222 MBP 74 120 148 40 0.69 95 1.14 92 149 184
PL35G 101G0250 M/HBP 53 89 112 172 209 28 0.58 69 1.04 140 1.55 66 111 140 214 261
PLE50F 101G0221 MBP 76 122 150 42 0.81 97 1.31 95 152 187

R134a • 220-240 V • 50 Hz • P-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
PL20F 101G0100 103N0011 103N0018 103N1010 103N0491
PL35F 101G0202 103N0011 103N0018 103N1010 103N0491
PL50F 101G0220 103N0011 103N0018 103N1010 103N0491
PL50F 101G0222 117U6021 117U5014 103N1010 103N0491
PL35G 101G0250 103N0011 103N0018 117U6021 117U5014 103N1010 103N0491
PLE50F 101G0221 103N0016 103N0021 117-7117 117-7119 103N1010 103N0491

62

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

ASHRAE Dimensions

Run capacitor

Displacement

(refer-data sheet)
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
24 0.55 67 1.12 1/50 1.41 198-254 V, 50 Hz S 129 127 6.2 6.2 5.0 1|5
45 0.86 105 1.39 1/25 2.00 198-254 V, 50 Hz S 134 132 6.2 6.2 5.0 1|5
56 0.89 1/20 2.50 198-254 V, 50 Hz S 137 135 6.2 6.2 5.0 1|5
56 0.92 126 1.41 1/20 2.50 198-254 V, 50 Hz F1 137 135 6.2 6.2 5.0 1|5
39 0.79 93 1.31 174 1.89 1/20 2.00 198-254 V, 50 Hz * F1 137 135 6.2 6.2 5.0 X 3|9
59 1.08 128 1.63 4 1/20 2.50 198-254 V, 50 Hz S 140 138 6.2 6.2 5.0 1|5

PL / PLE

63

R134a
R134a • 220-240 V • 50 Hz • T-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TL2.5F 102G4200 L/MBP 65 110 137 32 0.59 86 1.07 81 136 170
TL3F 102G4300 L/MBP 82 138 173 42 0.64 108 1.09 101 171 215
TL4F 102G4400 LBP 31 107 61 0.75 137 1.12 38 133
TL5F 102G4501 LBP 43 144 82 0.81 183 1.19 53 178
TL2.5G 102G4251 L/M/HBP 11 69 116 145 219 264 36 0.60 90 1.08 179 1.58 14 86 144 181 273 331
TL3G 102G4350 L/M/HBP 80 136 170 258 312 41 0.62 106 1.10 211 1.59 100 169 212 322 390
TL4G 102G4452 L/M/HBP 107 180 226 342 413 58 0.70 140 1.19 280 1.82 133 223 281 426 515
TL4G 102G4458 L/M/HBP 107 180 226 342 413 58 0.70 140 1.19 280 1.82 133 223 281 426 515
TL5G 102G4550 L/M/HBP 139 224 278 414 497 79 0.79 178 1.19 341 1.67 173 278 345 515 620
TL4GH 102G4455 HBP 104 182 230 353 429 140 1.16 287 1.81 130 226 286 440 535
TLES3F 102G4310 L/MBP 93 155 193 50 0.81 121 1.31 115 192 240
TLES4F 102G4410 LBP 33 124 70 0.88 160 1.35 41 154
TLES5F 102G4510 LBP 50 169 98 0.93 216 1.37 62 210
TLES6F 102G4610 LBP 58 183 104 0.93 235 1.37 72 227
TLES5.7FT.3 102G4615 LBP 66 200 120 1.00 253 1.48 82 248
TLES6.5FT.3 102G4703 LBP 72 228 134 1.01 290 1.56 89 283
TLS5F 102G4520 LBP 48 170 98 0.88 216 1.33 59 210
TLS6F 102G4620 LBP 58 183 104 0.87 235 1.30 72 227
TLS7F 102G4720 LBP 66 208 120 0.88 264 1.28 82 258
TLS3FT 102G4324 LBP 21 92 50 0.80 120 1.30 26 115
TLS4FT 102G4424 LBP 27 117 63 0.72 152 1.24 34 145
TLS5FT 102G4524 LBP 48 170 98 0.86 216 1.30 59 210
TLY4F 102G4441 LBP 35 126 72 0.99 162 1.49 43 157
TLY5FK 102G4547 LBP 50 169 98 1.01 216 1.48 62 210

R134a • 220-240 V • 50 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TL2.5F 102G4200 103N0011 103N0018 103N1010 103N2010
TL3F 102G4300 103N0011 103N0018 117U6007 117U5014 103N1010 103N2010
TL4F 102G4400 103N0011 103N0018 117U6009 117U5014 103N1010 103N2010
TL5F 102G4501 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010
TL2.5G 102G4251 103N0011 103N0018 117U6007 117U5014 103N1010 103N2011
TL3G 102G4350 103N0011 103N0018 117U6009 117U5014 103N1010 103N2010
TL4G 102G4452 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010
TL4G 102G4458 103N0011 103N0018 117U6004 117U5014 103N1010 103N2011
TL5G 102G4550 103N0011 103N0018 117U6000 117U5014 103N1010 103N2010
TL4GH 102G4455 117U6000 117U5014 103N1010 103N2011
TLES3F 102G4310 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
TLES4F 102G4410 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
TLES5F 102G4510 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
TLES6F 102G4610 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
TLES5.7FT.3 102G4615 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 117U6004 117U5014 103N1010 103N2010
TLES6.5FT.3 102G4703 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 117U6016 117U5014 103N1010 103N2010
TLS5F 102G4520 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010
TLS6F 102G4620 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010
TLS7F 102G4720 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 117U6000 117U5014 103N1010 103N2010
TLS3FT 102G4324 103N0011 103N0018 117U6007 117U5014 103N1010 103N2010
TLS4FT 102G4424 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010
TLS5FT 102G4524 103N0011 103N0018 117U6000 117U5014 103N1010 103N2010
TLY4F 102G4441 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY5FK 102G4547 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010

64

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
46 0.80 115 1.35 1/25 2.61 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 1|7
59 0.85 144 1.36 1/20 3.13 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 1|7
84 0.98 1/10 3.86 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 1|7
113 1.06 1/10 5.08 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1|2|7
51 0.82 121 1.36 223 1.92 1/10 2.61 187-254 V, 50 Hz * S 163 159 6.2 6.2 5.0 X 3
59 0.85 142 1.38 262 1.93 1/10 3.13 187-254 V, 50 Hz * S 163 159 6.2 6.2 5.0 X 3
81 0.94 187 1.51 347 2.23 1/10 3.86 187-254 V, 50 Hz * S 173 169 6.2 6.2 5.0 X 3
81 0.94 187 1.51 347 2.23 1/10 3.86 187-254 V, 50 Hz * S 173 169 6.5 6.5 5.0 X 3
109 1.04 234 1.48 421 2.01 1/8 5.08 187-254 V, 50 Hz * S 173 169 6.2 6.2 5.0 X 3
189 1.48 357 2.21 1/10 3.86 198-254 V, 50 Hz * F2 173 169 6.2 6.2 5.0 8
70 1.07 161 1.62 * 1/10 3.13 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
97 1.16 * 1/10 3.86 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
134 1.22 * 1/8 5.08 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1|2
143 1.20 * 1/8 5.70 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 1|2
163 1.30 * 1/7 5.70 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 1|2
183 1.33 4* 1/6 6.49 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 2
134 1.15 1/8 5.08 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1|2
143 1.14 1/8 5.70 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1|2
165 1.15 * 1/7 6.49 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
69 1.07 1/10 3.13 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
88 0.97 1/10 3.86 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
134 1.12 1/8 5.08 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 1|2
99 1.30 4* 1/10 3.86 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
134 1.32 4* 1/8 5.08 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1|2

TL TLS / TLES / TLY

65

R134a
R134a • 220-240 V • 50 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NF7FX 105G6743 L/MBP 262 422 522 150 0.85 336 1.36 636 2.01 325 523 647
NF9FX 105G6841 L/MBP 288 464 577 168 0.84 369 1.31 709 1.94 357 576 716
NF10FX 105G6846 L/MBP 339 543 673 196 0.72 433 1.17 823 1.76 418 672 833
NF11FX 105G6944 L/MBP 368 585 725 216 0.74 467 1.17 887 1.72 455 726 899
NL6F 105G6606 LBP 52 200 110 0.93 258 1.39 64 248
NL7F 105G6706 LBP 71 238 136 0.93 303 1.31 88 295
NL8F 105G6822 LBP 82 249 149 0.97 317 1.37 100 308
NL9F 105G6802 LBP 74 268 155 0.93 340 1.31 92 332
NL11F 105G6900 LBP 102 351 200 0.94 453 1.37 127 436
NL6FT 105G6628 LBP 60 198 115 0.93 253 1.37 74 245
NL6.1FT 105G6620 LBP 60 198 115 0.93 253 1.37 74 245
NL7FT 105G6728 LBP 71 235 136 0.94 299 1.36 88 291
NL7.3FT 105G6726 LBP 71 235 136 0.94 299 1.36 88 291
NL7.3FT 105G6731 LBP 71 235 136 0.94 299 1.36 88 291
NL8.4FT 105G6865 LBP 87 275 162 0.95 350 1.39 107 341
NL8.4FT 105G6866 LBP 87 275 162 0.95 350 1.39 107 341
NL9FT 105G6828 LBP 87 275 162 0.95 350 1.39 107 341
NL10FT 105G6829 LBP 115 352 210 0.98 444 1.40 141 434
NL10FT 105G6839 LBP 115 352 210 0.98 444 1.40 141 434
NL6.1MF 105G6660 MBP 189 312 390 588 709 245 1.31 482 1.98 234 388 486 733 886
NL7.3MF 105G6772 MBP 236 385 480 719 867 304 1.34 591 1.98 293 478 597 896 1082
NL8.4MF 105G6879 MBP 277 445 553 825 994 353 1.36 679 1.94 343 552 687 1029 1242
NL10MF 105G6885 MBP 346 554 687 1023 1231 441 1.37 843 1.94 429 688 854 1274 1536
NL11MF 105G6151 M/HBP 380 609 756 1125 1354 485 1.35 927 1.87 471 756 939 1402 1689
NLE10MF 105G6888 MBP 88 343 554 688 194 0.98 440 1.43 845 1.98 110 426 687 855

R134a • 220-240 V • 50 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NF7FX 105G6743 117U4140 117U5018 117U0349 117U1023
NF9FX 105G6841 117U4140 117U5018 117U0349 117U1021
NF10FX 105G6846 117U4139 117U5018 117U0349 117U1023
NF11FX 105G6944 117U4139 117U5018 117U0349 117U1023
NL6F 105G6606 103N0011 103N0018 117U6004 117U5015 103N1010 103N2010
NL7F 105G6706 103N0011 103N0018 117U6000 117U5015 103N1010 103N2010
NL8F 105G6822 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL9F 105G6802 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL11F 105G6900 103N0011 103N0018 117U6002 117U5015 103N1010 103N2010
NL6FT 105G6628 103N0011 103N0018 117U6000 117U5015 103N1010 103N2010
NL6.1FT 105G6620 103N0011 103N0018 117U6017 117U5015 103N1010 103N2010
NL7FT 105G6728 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL7.3FT 105G6726 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL7.3FT 105G6731 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL8.4FT 105G6865 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL8.4FT 105G6866 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
NL9FT 105G6828 103N0011 103N0018 117U6015 117U5015 103N1010 103N2010
NL10FT 105G6829 103N0011 103N0018 117U6002 117U5015 103N1010 103N2010
NL10FT 105G6839 103N0011 103N0018 117U6002 117U5015 103N1010 103N2010
NL6.1MF 105G6660 103N0011 103N0018 117U6015 117U5015 103N1010 103N2011
NL7.3MF 105G6772 103N0011 103N0018 117U6016 117U5015 103N1010 103N2011
NL8.4MF 105G6879 103N0011 103N0018 117U6016 117U5018 103N1010 103N2011
NL10MF 105G6885 103N0011 103N0018 117U6022 117U5018 103N1010 103N2011
NL11MF 105G6151 103N0011 103N0018 117U6022 117U5018 103N1010 103N2011
NLE10MF 105G6888 103N0011 103N0018 103N0050 117U6003 117U5015 103N1010 103N2010

66

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
206 1.12 441 1.71 781 2.43 1/4 7.27 198-242 V, 50 Hz * S 203 197 8.2 6.5 6.5 X 3
229 1.10 485 1.64 874 2.36 1/4 8.34 198-242 V, 50 Hz F1 203 197 8.2 6.5 6.5 X 3
267 0.95 567 1.47 1011 2.13 1/3 10.09 198-242 V, 50 Hz * F1 203 197 8.2 6.5 6.5 X 3
294 0.97 612 1.46 1092 2.08 1/3 11.15 198-242 V, 50 Hz F2 203 197 8.2 6.5 6.5 X 3
152 1.22 1/7 6.13 198-254 V, 50 Hz S 188 181 6.2 6.2 5.0 2
187 1.21 1/6 7.27 198-254 V, 50 Hz S 190 183 6.2 6.2 5.0 2
201 1.25 1/5 7.95 198-254 V, 50 Hz S 197 191 6.2 6.2 5.0 2
213 1.21 1/5 8.35 198-254 V, 50 Hz S 197 191 8.2 6.2 6.2 2
274 1.23 1/4 11.15 198-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 X 2
157 1.21 1/7 6.13 187-254 V, 50 Hz * S 197 191 6.2 6.2 5.0 2
157 1.21 1/7 6.13 187-254 V, 50 Hz S 188 182 6.2 6.2 5.0 2|4
186 1.22 1/6 7.27 187-254 V, 50 Hz S 197 191 6.2 6.2 5.0 2|4
186 1.22 1/6 7.27 187-254 V, 50 Hz S 188 182 6.2 6.2 5.0 2|4
186 1.22 1/6 7.27 187-254 V, 50 Hz S 188 182 6.2 6.2 5.0 5.0 2|4
220 1.24 1/5 8.35 187-254 V, 50 Hz F1 190 184 6.2 6.2 5.0 X 2|4
220 1.24 1/5 8.35 187-254 V, 50 Hz F1 190 184 6.2 6.2 5.0 5.0 X 2|4
220 1.24 1/5 8.35 187-254 V, 50 Hz S 197 191 6.2 6.2 5.0 X 2|4
285 1.25 1/4 10.09 187-254 V, 50 Hz S 203 197 8.2 6.2 6.2 X 2|4
285 1.25 1/4 10.09 187-254 V, 50 Hz S 203 197 8.2 6.2 6.2 6.2 X 2|4
326 1.66 597 2.41 1/6 6.13 187-254 V, 50 Hz * S 190 184 8.2 6.2 6.2 X 3
402 1.69 731 2.40 1/5 7.27 187-254 V, 50 Hz * F1 197 191 8.2 6.2 6.2 X 3
465 1.69 839 2.35 1/4 8.35 187-254 V, 50 Hz * F1 197 191 8.2 6.2 6.2 X 3
580 1.70 1040 2.35 1/3 10.09 187-254 V, 50 Hz * F1 203 197 8.2 6.2 6.2 X 3
638 1.66 1144 2.26 1/3 11.15 187-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 X 3
268 1.28 579 1.76 1044 2.40 * 1/3 10.09 198-254 V, 50 Hz F1 203 197 8.2 6.2 6.2 3

NF NL / NLE

67

R134a
R134a • 220-240 V • 50 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54,4°C, Tliq=32,2°C, Tsuc=32,2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NLY6F 105G6630 LBP 80 235 138 1.17 299 1.65 99 291
NLY7F 105G6730 LBP 94 265 158 1.18 334 1.67 115 328
NLY7F 105G6735 LBP 94 265 158 1.18 334 1.67 115 328
NLY9FK 105G6814 LBP 92 291 171 1.13 372 1.60 115 361
NLY9FK 105G6830 LBP 94 297 175 1.15 380 1.63 117 368

R134a • 220-240 V • 50 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NLY6F 105G6630 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLY7F 105G6730 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLY7F 105G6735 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLY9FK 105G6814 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLY9FK 105G6830 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010

68

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
188 1.51 4 1/6 6.70 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
214 1.53 4 1/5 7.27 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
214 1.53 4 1/5 7.27 198-254 V, 50 Hz S 203 197 6.5 6.5 5.0 X 2
233 1.47 4 1/5 8.35 198-254 V, 50 Hz S 203 197 6.5 6.5 4.9 X 2
238 1.50 4 1/5 8.35 198-254 V, 50 Hz S 203 197 8.2 6.2 6.2 X 2

NLY

69

R134a
R134a • 220-240 V • 50 Hz • F-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
FR6G 103G6660 L/M/HBP 171 290 365 552 83 0.76 226 1.32 452 1.88 213 360 453 688
FR7.5G 103G6680 L/M/HBP 193 325 408 618 99 0.79 254 1.30 505 1.86 240 403 507 770
FR7.5G 103G6690 L/M/HBP 193 325 408 618 99 0.79 254 1.30 505 1.86 240 403 507 770
FR8.5G 103G6780 L/M/HBP 228 381 478 722 123 0.82 298 1.29 592 1.84 284 473 594 900
FR8.5G 103G6790 L/M/HBP 228 381 478 722 123 0.82 298 1.29 592 1.84 284 473 594 900
FR10G 103G6880 L/M/HBP 250 412 516 779 136 0.76 324 1.22 638 1.76 310 511 641 970
FR10G 103G6890 L/M/HBP 250 412 516 779 136 0.76 324 1.22 638 1.76 310 511 641 970
FR11G 103G6980 L/M/HBP 307 501 628 170 0.84 395 1.25 780 1.75 381 622 781
FR7GH 103G6683 HBP 199 327 417 655 807 255 1.33 525 2.04 247 408 520 818 1009
FR7GH 103G6692 HBP 199 327 417 655 807 255 1.33 525 2.04 247 408 520 818 1009

R134a • 220-240 V • 50 Hz • F-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
FR6G 103G6660 103N0011 103N0018 117U6000 117U5015 103N1010 103N2010
FR7.5G 103G6680 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
FR7.5G 103G6690 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
FR8.5G 103G6780 103N0011 103N0018 117U6015 117U5015 103N1010 103N2010
FR8.5G 103G6790 103N0011 103N0018 117U6015 117U5015 103N1010 103N2010
FR10G 103G6880 103N0011 103N0018 117U6010 117U5015 103N1010 103N2010
FR10G 103G6890 103N0011 103N0018 117U6010 117U5015 103N1010 103N2010
FR11G 103G6980 103N0011 103N0018 117U6010 117U5015 103N1010 103N2010
FR7GH 103G6683 117U6016 117U5015 103N1010 103N2011
FR7GH 103G6692 117U6016 117U5015 103N1010 103N2011

70

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
121 1.04 302 1.64 560 2.28 1/6 6.23 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 3
141 1.06 338 1.62 626 2.25 1/5 6.93 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 X 3
141 1.06 338 1.62 626 2.25 1/5 6.93 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 6.2 3
172 1.08 397 1.60 732 2.23 1/5 7.95 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 3
172 1.08 397 1.60 732 2.23 1/5 7.95 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 6.2 3
189 1.01 429 1.53 789 2.14 1/4 9.05 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 X 3
189 1.01 429 1.53 789 2.14 1/4 9.05 187-254 V, 50 Hz * F1 196 191 8.2 6.2 6.2 6.2 3
236 1.10 523 1.54 1/5 11.15 187-254 V, 50 Hz F2 196 191 8.2 6.2 6.2 X 3
341 1.65 658 2.52 1/5 6.93 198-254 V, 50 Hz * F2 196 191 8.2 6.2 8.2 8
341 1.65 658 2.52 1/5 6.93 198-254 V, 50 Hz * F2 196 191 8.2 6.2 8.2 8.2 8

FR

71

R134a
R134a • 220-240 V • 50 Hz • S-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC15F 104G8500 LBP 100 439 726 230 0.84 573 1.33 126 546 902
SC18F 104G8800 LBP 129 518 842 280 0.90 669 1.36 159 641 1042
SC21F 104G8100 LBP 186 602 987 335 0.88 780 1.30 228 743 1219
SC21F 104G8110 LBP 186 602 987 335 0.88 780 1.30 228 743 1219
SC12FT 104G8205 LBP 103 408 645 233 0.88 517 1.36 129 506 803
SC12FT 104G8215 LBP 103 408 645 233 0.88 517 1.36 129 506 803
SC15FT 104G8505 LBP 126 489 772 280 0.90 620 1.38 158 607 959
SC18FTX 104G8805 LBP 144 567 896 325 0.89 719 1.39 181 704 1115
SC21FTX 104G8105 LBP 192 713 1119 415 0.97 901 1.47 241 886 1393
SC10G 104G8000 L/M/HBP 23 268 486 618 925 1100 113 0.63 369 1.27 764 2.00 30 334 604 767 1150 1370
SC12G 104G8240 L/M/HBP 65 348 603 768 1182 1437 175 0.77 464 1.31 960 1.95 81 433 750 955 1473 1794
SC12G 104G8250 L/M/HBP 65 348 603 768 1182 1437 175 0.77 464 1.31 960 1.95 81 433 750 955 1473 1794
SC15G 104G8520 L/M/HBP 424 728 908 1340 1600 164 0.71 568 1.29 1110 1.87 528 905 1129 1671 2001
SC18G 104G8820 L/M/HBP 532 873 1087 1619 1942 286 0.88 689 1.31 1335 1.89 659 1083 1349 2014 2420
SC18G 104G8830 L/M/HBP 532 873 1087 1619 1942 286 0.88 689 1.31 1335 1.89 659 1083 1349 2014 2420
SC21G 104G8140 L/M/HBP 606 1013 1269 1889 2254 333 0.96 793 1.39 1561 2.04 756 1262 1581 2355 2814
SC10GH 104G8041 HBP 233 478 613 927 1113 352 1.25 762 1.93 290 593 762 1158 1394
SC12GH 104G8261 HBP 302 577 752 1196 1471 429 1.20 957 1.97 378 719 937 1491 1837
SC15GH 104G8561 HBP 417 723 915 1398 1698 559 1.32 1139 2.02 518 899 1139 1744 2120
SC18GH 104G8860 HBP 539 855 1077 1645 1990 676 1.36 1340 1.92 667 1063 1340 2051 2485
SC18GH 104G8861 HBP 485 825 1047 1618 1976 639 1.42 1310 2.17 603 1026 1303 2018 2468
SC10GHH 104G8071 HBP 259 467 604 942 1144 352 1.35 762 2.21 322 581 751 1174 1428
SC15GHH 104G8571 HBP 435 726 911 1405 1731 570 1.51 1135 2.25 534 898 1130 1748 2157

R134a • 220-240 V • 50 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC15F 104G8500 103N0011 117U6003 117U5017 103N1004 103N2009
SC18F 104G8800 117U6005 117U5017 103N1004 103N2009
SC21F 104G8100 117U6019 117U5017 103N1004 103N2009
SC21F 104G8110 117U6019 117U5017 103N1004 103N2009
SC12FT 104G8205 103N0011 117U6003 117U5017 103N1004 103N2009
SC12FT 104G8215 103N0011 117U6003 117U5017 103N1004 103N2009
SC15FT 104G8505 103N0011 117U6005 117U5017 103N1004 103N2009
SC18FTX 104G8805 117U6019 117U5017 103N1004 103N2009
SC21FTX 104G8105 117U6019 117U5017 103N1004 103N2009
SC10G 104G8000 103N0011 117U6002 117U5017 103N1004 103N2009
SC12G 104G8240 103N0011 117U6003 117U5017 103N1004 103N2008
SC12G 104G8250 103N0011 117U6003 117U5017 103N1004 103N2009
SC15G 104G8520 117U6005 117U5017 103N1004 103N2009
SC18G 104G8820 117U6019 117U5017 103N1004 103N2009
SC18G 104G8830 117U6019 117U5017 103N1004 103N2009
SC21G 104G8140 117U5373 117-7029 103N1004 103N2009
SC10GH 104G8041 117U6005 117U5017 103N1004 103N2008
SC12GH 104G8261 117U6011 117U5017 103N1004 103N2008
SC15GH 104G8561 117U6011 117U5017 103N1004 103N2008
SC18GH 104G8860 117U6019 117U5017 103N1004 103N2009
SC18GH 104G8861 117U5373 117-7039 103N1004 103N2008
SC10GHH 104G8071 117U5372 117-7025 103N1004 103N2009
SC15GHH 104G8571 117U5373 117-7027 103N1004 103N2009

72

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
324 1.11 759 1.63 1/3 15.28 198-254 V, 50 Hz F1 209 203 8.2 6.2 6.2 4
389 1.17 879 1.67 1/3 17.69 198-254 V, 50 Hz F1 209 203 10.2 6.2 6.2 4
458 1.14 1026 1.59 1/2 20.95 198-254 V, 50 Hz F1 219 213 10.2 6.2 6.2 4
458 1.14 1026 1.59 1/2 20.95 198-254 V, 50 Hz F1 219 213 10.2 6.2 6.2 6.2 4
322 1.16 678 1.69 1/3 12.87 187-254 V, 50 Hz * F1 209 203 8.2 6.2 6.2 4
322 1.16 678 1.69 1/3 12.87 187-254 V, 50 Hz * F1 209 203 8.2 6.2 6.2 6.2 4
386 1.18 811 1.70 1/3 15.28 187-254 V, 50 Hz * F2 209 203 10.2 6.2 6.2 X 4
448 1.17 942 1.73 1/2 17.69 187-254 V, 50 Hz * F2 219 213 10.2 6.2 6.2 X 4
570 1.27 1178 1.82 1/2 20.95 187-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 4
169 0.87 502 1.64 942 2.43 1/3 10.29 187-254 V, 50 Hz * F2 199 193 8.2 6.2 6.2 3
249 1.03 626 1.65 1194 2.36 1/3 12.87 187-254 V, 50 Hz * F2 209 203 8.2 6.2 6.2 X 3
249 1.03 626 1.65 1194 2.36 1/3 12.87 187-254 V, 50 Hz * F2 209 203 8.2 6.2 6.2 6.2 3
261 1.01 760 1.61 1369 2.27 1/2 15.28 187-254 V, 50 Hz * F2 209 203 10.2 6.2 6.2 X 3
398 1.14 910 1.63 1645 2.29 1/2 17.69 187-254 V, 50 Hz * F2 219 213 10.2 6.2 6.2 X 3
398 1.14 910 1.63 1645 2.29 1/3 17.69 187-254 V, 50 Hz * F2 219 213 10.2 6.2 6.2 6.2 3
462 1.23 1059 1.73 1928 2.48 10 3/4 20.95 187-254 V, 50 Hz * F2 219 213 10.2 6.2 6.2 X 3
490 1.61 944 2.35 1/3 10.29 198-254 V, 50 Hz * F2 209 203 10.2 6.2 8.2 8
594 1.56 1199 2.42 1/3 12.87 198-254 V, 50 Hz * F2 209 203 10.2 6.2 8.2 8
751 1.65 1415 2.49 1/2 15.28 198-254 V, 50 Hz * F2 209 203 10.2 6.2 8.2 X 8
892 1.67 1665 2.35 1/2 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 8.2 8
857 1.79 1632 2.66 10 1/2 17.69 198-254 V, 50 Hz * F2 219 213 10.2 6.2 8.2 8
481 1.75 950 2.71 5 1/3 10.29 198-254 V, 50 Hz F1 209 203 10.2 6.2 8.2 8.2 8
753 1.89 1410 2.75 10 1/2 15.28 198-254 V, 50 Hz F1 209 203 10.2 6.2 8.2 8.2 X 8

SC

73

R134a
R134a • 220-240 V • 50 Hz • S-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC15MFX 104G8501 MBP 458 767 954 1405 226 0.81 602 1.38 1166 1.97 569 952 1186 1751
SC18MFX 104G8804 MBP 553 894 1113 1670 709 1.34 1370 1.94 686 1109 1382 2079
SC21MFX 104G8120 MBP 662 1052 1303 1936 840 1.37 1596 1.96 820 1306 1618 2411
SC12/12G 104G8280 L/M/HBP 129 696 1206 1535 2364 2875 350 0.77 928 1.31 1920 1.95 163 866 1500 1910 2946 3587
SC15/15G 104G8580 L/M/HBP 847 1457 1815 2679 3201 328 0.71 1137 1.29 2220 1.87 1055 1811 2258 3342 4001
SC18/18G 104G8880 L/M/HBP 1053 1740 2174 3248 3900 566 0.86 1369 1.35 2674 1.92 1299 2153 2691 4032 4850
SC21/21G 104G8180 L/M/HBP 1212 2026 2538 3778 4510 665 0.86 1584 1.37 3121 1.97 1510 2523 3160 4710 5630

R134a • 220-240 V • 50 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC15MFX 104G8501 117U6005 117U5017 103N1004 103N2008
SC18MFX 104G8804 117U6019 117U5017 117-7027 103N1004 103N2008
SC21MFX 104G8120 117U6019 117U5017 117-7039 103N1004 103N2009
SC12/12G 104G8280 117U6003 117U5017 103N1004 103N2009
SC15/15G 104G8580 117U6005 117U5017 103N1004 103N2009
SC18/18G 104G8880 117U6019 117U5017 103N1004 103N2009
SC21/21G 104G8180 117U5373 117-7029 103N1004 103N2009

74

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
326 1.10 800 1.71 1436 2.38 1/2 15.28 198-254 V, 50 Hz F2 209 203 10.2 6.2 6.2 3
434 1.15 933 1.68 1694 2.36 * 1/2 17.69 187-254 V, 50 Hz * F2 219 213 10.2 6.2 6.2 3
533 1.21 1101 1.70 1969 2.38 * 3/4 20.95 187-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 3
497 1.03 1252 1.65 2388 2.36 3/4 25.74 187-254 V, 50 Hz F2 249 244 12.0 6.2 6.2 3
522 1.01 1519 1.61 2737 2.27 3/4 30.56 187-254 V, 50 Hz F2 249 244 12.0 6.2 6.2 3
783 1.12 1808 1.68 3291 2.31 1 35.38 187-254 V, 50 Hz F2 259 254 16.0 6.2 6.2 3
923 1.13 2116 1.72 3855 2.37 10 1 1/4 41.90 187-254 V, 50 Hz F2 259 254 16.0 6.2 6.2 3

SC SC-Twin

75

R134a
R134a • 220-240 V • 50 Hz • G-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
GS26MFX 107B0700 MBP 938 1523 1893 1207 1.72 2327 2.37 1164 1892 2354
GS34MFX 107B0701 MBP 1217 1992 2487 1572 1.68 3069 2.40 1511 2473 3090
GS26GHX 107B0702 HBP 877 1407 1749 2624 3173 1119 1.48 2152 2.13 1088 1748 2175 3273 3965

R134a • 220-240 V • 50 Hz • G-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
GS26MFX 107B0700 117-7055 107B9101
GS34MFX 107B0701 117-7056 107B9101
GS26GHX 107B0702 117-7070 107B9101

76

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
1592 2.13 10 3/4 26.30 198-254 V, 50 Hz F2 259 247 12.9 6.5 8.2 3
2079 2.10 3799 2.90 10 1 33.80 198-254 V, 50 Hz F2 259 247 12.9 6.5 8.2 3
1472 1.84 2664 2.58 20 3/4 26.30 198-254 V, 50 Hz F2 259 247 12.9 6.5 8.2 8

GS

77

R134a
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R600a
220-240 V | 50 Hz

P-Series............................................................................................................................................................80-81
T-Series............................................................................................................................................................82-85
X-Series............................................................................................................................................................86-87
D-Series............................................................................................................................................................88-89
N-Series............................................................................................................................................................90-93
KAPPA...............................................................................................................................................................94-95
DELTA................................................................................................................................................................96-97

Chemical formula Starting devices


C4H10 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Red The PTC starting device requires 5 minutes cooling before
Typelabel colour: Yellow each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

78
79
R600a • 220-240 V • 50 Hz • P-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
PLE35K 101H0360 MBP 52 87 109 27 0.68 68 1.28 63 106 133

R600a • 220-240 V • 50 Hz • P-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
PLE35K 101H0360 103N0016 103N0021 117-7117 117-7119 103N1010 103N0491

80

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
38 0.91 90 1.60 4 1/25 2.50 198-254 V, 50 Hz S 137 135 6.2 6.2 5.0 X 1|5

PLE

81

R600a
R600a • 220-240 V • 50 Hz • T-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C. Tliq=55°C. Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TLES4KK.3 102H4438 LBP 18 75 42 0.90 96 1.43 23 91
TLES4.8KK.3 102H4538 LBP 28 94 55 1.00 119 1.53 34 115
TLES5.7KK.3 102H4638 LBP 36 114 68 1.02 144 1.54 45 139
TLES6.5KK.3 102H4738 LBP 45 134 81 1.02 168 1.51 55 163
TLES7.5KK.3 102H4838 LBP 53 155 94 1.02 194 1.52 64 189
TLES8.7KK.3 102H4938 LBP 62 181 110 1.03 228 1.53 75 221
TLES10KK.3 102H4038 LBP 73 205 126 0.98 255 1.43 89 250
TLES4KTK 102H4436 LBP 18 74 123 154 40 0.83 96 1.49 22 91 151 189
TLES5KTK 102H4536 LBP 28 99 159 196 57 0.93 126 1.49 34 121 194 240
TLES6KTK 102H4636 LBP 31 112 66 0.95 140 1.44 38 136
TLES7KTK 102H4736 LBP 40 130 77 0.95 163 1.41 49 158
TLES8KTK 102H4836 LBP 48 149 89 0.95 188 1.40 59 182
TLES8.7KTK.3 102H4834 LBP 58 178 107 0.98 224 1.49 71 217
TLES10KTK.3 102H4050 LBP 73 205 126 1.06 255 1.54 89 250
TLX4KK.3 102H4447 LBP 21 76 44 1.15 95 1.74 25 92
TLX5.7KK.3 102H4647 LBP 37 115 70 1.28 143 1.85 46 140
TLX6.5KK.3 102H4747 LBP 46 133 83 1.30 165 1.83 57 163
TLX7.5KK.3 102H4847 LBP 55 157 98 1.32 195 1.86 67 192
TLX8.7KK.3 102H4947 LBP 65 184 115 1.31 227 1.84 79 224

R600a • 220-240 V • 50 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TLES4KK.3 102H4438 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES4.8KK.3 102H4538 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES5.7KK.3 102H4638 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES6.5KK.3 102H4738 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES7.5KK.3 102H4838 103N0011 103N0018 103N0016 103N0021 103N0050 117-7131 117-7132 103N1010 103N2010
TLES8.7KK.3 102H4938 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES10KK.3 102H4038 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES4KTK 102H4436 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES5KTK 102H4536 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES6KTK 102H4636 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES7KTK 102H4736 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES8KTK 102H4836 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLES8.7KTK.3 102H4834 103N0011 103N0018 103N1010 103N2010
TLES10KTK.3 102H4050 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLX4KK.3 102H4447 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLX5.7KK.3 102H4647 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLX6.5KK.3 102H4747 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLX7.5KK.3 102H4847 103N0016 103N0021 103N0050 117-7131 117-7132 103N1010 103N2010
TLX8.7KK.3 102H4947 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010

82

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
57 1.18 * 1/20 4.01 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 1|7
74 1.30 * 1/10 4.78 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 1|7
91 1.32 * 1/10 5.70 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 1|2
108 1.31 * 1/10 6.49 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 2
126 1.32 * 1/10 7.48 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 2
147 1.33 * 1/8 8.67 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 2
168 1.26 * 1/7 10.13 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
55 1.10 127 1.87 * 1/20 3.86 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
77 1.22 165 1.83 * 1/10 5.08 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 1
89 1.23 * 1/10 5.70 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
103 1.23 * 1/10 6.49 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
119 1.22 * 1/10 7.76 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
143 1.27 1/8 8.67 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
168 1.36 * 1/7 10.13 187-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2
60 1.49 4 1/10 4.01 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 1
94 1.65 4 1/10 5.70 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 1|2
111 1.66 4 1/10 6.49 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 2
130 1.69 3 1/8 7.48 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 2
153 1.68 4 1/7 8.67 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 X 2

TLES / TLX

83

R600a
R600a • 220-240 V • 50 Hz • T-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TLY4KK.3 102H4442 LBP 19 75 42 0.99 95 1.58 23 91
TLY4.8KK.3 102H4542 LBP 28 94 55 1.06 119 1.62 34 115
TLY5.7KK.3 102H4642 LBP 36 114 68 1.06 144 1.61 45 139
TLY6.5KK.3 102H4742 LBP 46 135 82 1.10 170 1.63 56 165
TLY7.5KK.3 102H4842 LBP 53 155 94 1.09 194 1.62 64 189
TLY8.7KK.3 102H4942 LBP 65 182 112 1.16 227 1.69 79 222
TLY10KK.3 102H4042 LBP 74 208 128 1.21 260 1.74 90 254

R600a • 220-240 V • 50 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TLY4KK.3 102H4442 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY4.8KK.3 102H4542 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY5.7KK.3 102H4642 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY6.5KK.3 102H4742 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY7.5KK.3 102H4842 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY8.7KK.3 102H4942 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
TLY10KK.3 102H4042 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010

84

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
57 1.29 4* 1/20 4.01 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 1
74 1.37 4* 1/10 4.78 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 1
91 1.37 4* 1/10 5.70 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 1|2
110 1.42 4* 1/10 6.49 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 2
126 1.41 4* 1/10 7.48 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 2
149 1.49 4* 1/8 8.67 198-254 V, 50 Hz S 163 159 6.2 6.2 5.0 X 2
170 1.55 4* 1/7 10.13 198-254 V, 50 Hz S 173 169 6.2 6.2 5.0 2

TLY

85

R600a
R600a • 220-240 V • 50 Hz • X-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
XV5.0KX 1000 rpm 108H5012 LBP 8 29 43 50 16 1.29 36 1.99 10 36 54 63
XV5.0KX 1500 rpm 108H5012 LBP 9 47 72 84 25 1.35 59 2.02 12 58 89 104
XV5.0KX 2500 rpm 108H5012 LBP 27 75 112 130 45 1.37 93 2.03 32 92 138 161
XV5.0KX 4000 rpm 108H5012 LBP 34 127 196 230 67 1.28 161 1.89 41 155 240 282

XV7.2KX 1000 rpm 108H7210 LBP 17 52 87 107 28 1.39 69 2.12 21 65 107 131
XV7.2KX 2000 rpm 108H7210 LBP 31 105 168 203 57 1.41 135 2.06 39 129 206 249
XV7.2KX 3000 rpm 108H7210 LBP 47 153 242 84 1.35 195 1.96 58 187 297
XV7.2KX 4000 rpm 108H7210 LBP 62 192 106 1.31 247 1.92 76 236

XV8.0KX 1000 rpm 108H7710 LBP 17 57 87 101 32 1.40 72 2.14 21 70 106 124
XV8.0KX 1500 rpm 108H7710 LBP 27 88 131 154 52 1.46 109 2.14 33 108 160 188
XV8.0KX 2500 rpm 108H7710 LBP 40 142 215 81 1.42 177 2.04 49 173 263
XV8.0KX 4000 rpm 108H7710 LBP 65 214 122 1.33 270 1.94 80 262

R600a • 220-240 V • 50 Hz • X-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
XV5.0KX 108H5012
Electronic unit 105N5022 (attached) - XV-AEO/Freq., inputs: Modbus, thermostat, frequency signal
XV7.2KX 108H7210
Electronic unit 105N5052 (detached) - XV-Frequency, input: frequency signal
XV8.0KX 108H7710

86

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location / diameter

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C (I.D.) D (O.D.) E (0.D.) F
22 1.67 47 2.45 1/8 5.0 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 1|9
35 1.75 77 2.46 1/8 5.0 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 1|9
60 1.77 119 2.46 1/8 5.0 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 1|9
93 1.66 207 2.30 1/8 5.0 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 1|9

39 1.80 90 2.60 1/5 7.2 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2


79 1.82 176 2.51 1/5 7.2 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2
115 1.74 254 2.37 1/5 7.2 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2
145 1.69 1/5 7.2 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2

44 1.82 92 2.61 1/5 7.7 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2


70 1.88 139 2.60 1/5 7.7 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2
110 1.83 226 2.47 1/5 7.7 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2
165 1.72 1/5 7.7 160-264 V, 50 Hz * S 97 91 6.2 6.0 3.2 2

XV

87

R600a
R600a • 220-240 V • 50 Hz • D-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
DLE5.7KK 102H4696 LBP 42 124 186 75 1.24 154 1.73 51 152 227
DLE7.5KK 102H4890 LBP 53 153 96 1.25 189 1.69 65 186
DLE8.7KK 102H4950 LBP 63 179 112 1.23 226 1.68 76 219
DLE9.4KK 102H4952 LBP 71 195 123 1.22 246 1.67 87 238
DLE10KK 102H4082 LBP 78 216 138 1.23 271 1.68 95 264
DLY7.5KK 102H4891 LBP 55 156 96 1.39 195 1.96 67 190
DLY8.7KK 102H4951 LBP 66 183 114 1.37 226 1.93 81 223
DLY9.4KK 102H4953 LBP 73 201 125 1.36 249 1.90 89 245
DLY10KK 102H4083 LBP 74 217 133 1.32 274 1.78 91 265
DLX4KK.1 102H3459 LBP 23 79 46 1.44 101 2.19 28 97
DLX4.8KK.1 102H3559 LBP 30 104 60 1.47 131 2.20 36 127
DLX5.7KK.1 102H3659 LBP 41 123 75 1.47 154 2.08 51 151
DLX6.5KK.1 102H3759 LBP 44 131 80 1.49 164 2.11 54 161
DLX7.5KK.1 102H4859 LBP 52 156 95 1.49 195 2.10 64 191
DLX8.7KK.1 102H4959 LBP 62 186 113 1.49 232 2.10 76 227
DLX9.4KK.1 102H4159 LBP 69 207 126 1.48 259 2.08 85 253
DLX10KK.1 102H4059 LBP 76 227 138 1.47 284 2.07 93 277

R600a • 220-240 V • 50 Hz • D-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
DLE5.7KK 102H4696 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLE9.4KK 102H4890 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLE8.7KK 102H4950 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLE9.4KK 102H4952 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLE10KK 102H4082 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLY7.5KK 102H4891 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLY8.7KK 102H4951 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLY9.4KK 102H4953 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLY10KK 102H4083 103N0016 103N0021 103N0050 117-7119 103N1010 103N0491
DLX4KK.1 102H3459 103N0016 103N0021 103N0055 117-7136 103N1010 103N0491
DLX4.8KK.1 102H3559 103N0016 103N0021 103N0055 117-7136 103N1010 103N0491
DLX5.7KK.1 102H3659 103N0016 103N0021 103N0055 117-7136 103N1010 103N0491
DLX6.5KK.1 102H3759 103N0016 103N0021 103N0055 117-7136 103N1010 103N0491
DLX7.5KK.1 102H4859 103N0016 103N0021 103N0055 117-7139 103N1010 103N0491
DLX8.7KK.1 102H4959 103N0016 103N0021 103N0055 117-7139 103N1010 103N0491
DLX9.4KK.1 102H4159 103N0016 103N0021 103N0055 117-7140 103N1010 103N0491
DLX10KK.1 102H4059 103N0016 103N0021 103N0055 117-7132 103N1010 103N0491

88

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
101 1.59 196 2.09 * 1/10 5.70 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 1|2|9
128 1.59 * 1/10 7.48 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9
148 1.56 * 1/7 8.67 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 2|9
163 1.55 * 1/7 9.38 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9
182 1.56 * 1/6 10.14 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 2|9
128 1.78 4 1/10 7.48 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 2|9
152 1.75 4 1/7 8.67 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 2|9
167 1.73 4 1/7 9.38 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 2|9
177 1.67 4 1/6 10.14 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9
62 1.86 2 1/10 4.01 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 1|9
81 1.90 2 1/10 4.78 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 1|9
100 1.89 2 1/10 5.70 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 1|2|9
107 1.91 2 1/10 6.49 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9
127 1.91 2.5 1/10 7.48 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9
151 1.91 2.5 1/7 8.67 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9
168 1.89 3.5 1/7 9.38 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 2|9
185 1.89 3 1/6 10.14 198-254 V, 50 Hz S 175 169 6.2 4.5 5.0 X 2|9

DLE / DLY / DLX

89

R600a
R600a • 220-240 V • 50 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NLE10KK.4 105H6867 LBP 74 207 128 1.19 257 1.60 90 252
NLE11KK.4 105H6952 LBP 81 232 143 1.19 290 1.62 100 283
NLE13KK.4 105H6959 LBP 99 274 170 1.18 340 1.59 121 334
NLE15KK.4 105H6968 LBP 110 307 190 1.20 382 1.63 134 374
NLE9KTK 105H6848 LBP 54 166 98 1.03 211 1.57 66 202
NLE11KTK 105H6948 LBP 73 206 127 1.03 261 1.47 88 251
NLE15KTK 105H6946 LBP 93 280 169 1.00 351 1.49 114 341
NLE11KTK.2 105H6173 LBP 84 242 149 1.18 302 1.72 102 295
NLE13KTK.2 105H6929 LBP 96 277 171 1.18 345 1.73 117 338
NLE15KTK.2 105H6966 LBP 106 314 190 1.19 395 1.72 129 384
NLE15MKK 105H6533 MBP 308 480 588 186 1.16 387 1.68 713 2.20 376 586 719
NLU8.0KK.1 105H6008 LBP 51 158 95 1.52 198 2.12 63 193
NLU10KK.1 105H6131 LBP 71 219 131 1.55 274 2.16 86 267
NLU11KK.1 105H6132 LBP 81 247 149 1.55 309 2.14 99 301
NLU13KK.1 105H6372 LBP 93 285 172 1.55 357 2.15 114 348
NLU15KK.1 105H6553 LBP 105 320 194 1.54 400 2.13 129 390
NLU11KTK.1 105H6133 LBP 83 253 153 1.45 317 2.02 102 309
NLU13KTK.1 105H6381 LBP 95 285 173 1.46 356 2.02 116 348
NLU15KTK.1 105H6554 LBP 106 321 195 1.45 401 2.00 130 392

R600a • 220-240 V • 50 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NLE10KK.4 105H6867 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLE11KK.4 105H6952 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLE13KK.4 105H6959 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLE15KK.4 105H6968 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLE9KTK 105H6848 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
NLE11KTK 105H6948 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
NLE15KTK 105H6946 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
NLE11KTK.2 105H6173 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLE13KTK.2 105H6929 103N0011 103N0018 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLE15KTK.2 105H6966 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
NLE15MKK 105H6533 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 103N1010 103N2010
NLU8.0KK.1 105H6008 103N0021 103N0055 117-7139 103N1010 103N2010
NLU10KK.1 105H6131 103N0021 103N0055 117-7139 103N1010 103N2010
NLU11KK.1 105H6132 103N0021 103N0055 117-7139 103N1010 103N2010
NLU13KK.1 105H6372 103N0021 103N0055 117-7132 103N1010 103N2010
NLU15KK.1 105H6553 103N0021 103N0055 117-7132 103N1010 103N2010
NLU11KTK.1 105H6133 103N0021 103N0055 117-7132 103N1010 103N2010
NLU13KTK.1 105H6381 103N0021 103N0055 117-7129 103N1010 103N2010
NLU15KTK.1 105H6554 103N0021 103N0055 117-7119 103N1010 103N2010

90

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
170 1.51 * 1/6 10.09 198-254 V, 50 Hz S 190 183 6.2 6.2 5.0 2
190 1.52 * 1/5 11.15 198-254 V, 50 Hz S 190 183 6.2 6.2 5.0 2
226 1.50 * 1/5 13.25 198-254 V, 50 Hz S 190 183 6.2 6.2 5.0 2
253 1.53 * 1/4 14.65 198-254 V, 50 Hz S 197 190 6.2 6.2 5.0 2
131 1.33 * 1/8 8.35 187-254 V, 50 Hz * S 197 190 6.2 6.2 5.0 2
168 1.31 * 1/7 11.15 187-254 V, 50 Hz * S 197 190 6.2 6.2 5.0 2
226 1.28 * 1/5 14.65 187-254 V, 50 Hz S 197 190 6.2 6.2 5.0 2
199 1.51 * 1/5 11.15 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
227 1.52 * 1/5 13.25 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
254 1.52 * 1/4 14.65 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
248 1.49 500 2.05 868 2.58 * 1/4 14.65 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2|3
127 1.94 2.5 1/10 8.05 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
176 1.98 2.5 1/6 10.09 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
200 1.97 2.5 1/5 11.15 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
230 1.98 3 1/5 13.25 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
259 1.96 3 1/4 14.65 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
205 1.85 3 1/5 11.15 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
231 1.87 5 1/5 13.25 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
260 1.85 4 1/4 14.65 187-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2

NLE NLU

91

R600a
R600a • 220-240 V • 50 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NLX10KK.1 105H6104 LBP 67 215 128 1.36 270 1.93 82 262
NLX13KK.1 105H6304 LBP 91 276 167 1.37 345 1.91 111 337
NLX15KK.1 105H6502 LBP 99 308 185 1.34 387 1.87 121 377
NLX8.0KK.2 105H6010 LBP 52 167 99 1.47 210 2.08 64 204
NLX8.8KK.2 105H6011 LBP 62 187 113 1.49 234 2.03 76 228
NLX10KK.2 105H6101 LBP 74 217 133 1.49 271 2.01 91 265
NLX11KK.2 105H6970 LBP 85 240 148 1.48 298 1.99 104 293
NLX13KK.2 105H6300 LBP 93 271 167 1.47 338 1.99 115 332
NLX15KK.2 105H6977 LBP 110 309 192 1.48 384 1.99 135 377
NLX10KK.3 105H6106 LBP 73 216 131 1.47 269 2.00 88 263
NLX11KK.3 105H6184 LBP 79 237 147 1.47 300 2.00 97 289
NLX13KK.3 105H6306 LBP 93 283 168 1.45 356 1.99 113 345
NLX15KK.3 105H6506 LBP 109 317 190 1.45 403 1.99 132 389

R600a • 220-240 V • 50 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NLX10KK.1 105H6104 103N0016 103N0021 103N0050 117-7131 117-7132 103N1010 103N2010
NLX13KK.1 105H6304 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLX15KK.1 105H6502 103N0016 103N0021 103N0050 117-7136 103N1010 103N2010
NLX8.0KK.2 105H6010 103N0016 103N0021 103N0050 117-7132 103N1010 103N2010
NLX8.8KK.2 105H6011 103N0016 103N0021 103N0050 117-7136 103N1010 103N2010
NLX10KK.2 105H6101 103N0016 103N0021 103N0050 117-7136 103N1010 103N2010
NLX11KK.2 105H6970 103N0016 103N0021 103N0050 117-7136 103N1010 103N2010
NLX13KK.2 105H6300 103N0016 103N0021 103N0050 117-7132 103N1010 103N2010
NLX15KK.2 105H6977 103N0016 103N0021 103N0050 117-7117 117-7119 103N1010 103N2010
NLX10KK.3 105H6106 103N0021 103N0050 117-7140 103N1010 103N2010
NLX11KK.3 105H6184 103N0021 103N0050 117-7119 103N1010 103N2010
NLX13KK.3 105H6306 103N0021 103N0050 117-7119 103N1010 103N2010
NLX15KK.3 105H6506 103N0021 103N0050 117-7140 103N1010 103N2010

92

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
172 1.74 3 1/6 10.09 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
224 1.75 4 1/5 13.25 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
248 1.71 2 1/4 14.65 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
133 1.88 3 1/8 8.05 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
151 1.89 2 1/7 8.76 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
178 1.89 2 1/6 10.09 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
198 1.88 2 1/5 11.15 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
222 1.87 3 1/5 13.25 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
255 1.88 4 1/4 14.65 198-254 V, 50 Hz S 203 197 8.2 6.2 6.2 X 2
175 1.87 4 1/6 10.09 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
195 1.86 4 1/6 11.15 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 X 2
225 1.85 4 1/5 13.25 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2
254 1.85 4 1/4 14.65 198-254 V, 50 Hz S 203 197 6.2 6.2 5.0 2

NLX

93

R600a
R600a • 220-240 V • 50 Hz • KAPPA
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
HMK80AA 15950000 LBP 55 170 102 1.18 211 1.68 67 207
HMK95AA 15460700 LBP 67 207 125 1.20 257 1.72 81 253
HMK12AA 16236200 LBP 82 239 149 1.21 292 1.66 100 291
HTK55AA 16122700 LBP 32 119 69 1.20 150 1.79 39 146
HTK70AA 16106100 LBP 44 150 87 1.26 185 1.85 54 182
HTK80AA 16068300 LBP 55 170 102 1.26 212 1.83 67 207
HTK95AA 16068200 LBP 71 207 126 1.29 258 1.82 86 252
HTK12AA 16111600 LBP 82 239 149 1.29 292 1.77 100 291
HKK55AA 16124400 LBP 32 120 69 1.37 150 2.00 39 146
HKK70AA 16124500 LBP 44 148 87 1.40 186 1.98 54 181
HKK80AA 16072100 LBP 55 170 102 1.40 212 1.99 67 207
HKK95AA 16049700 LBP 69 207 126 1.42 256 1.95 84 252
HKK12AA 16065900 LBP 82 239 149 1.42 292 1.93 100 291
HXK55AA 15650400 LBP 36 122 72 1.45 152 2.00 44 149
HXK70AA 15690400 LBP 47 149 88 1.47 186 2.02 57 181
HXK80AA 15621800 LBP 58 173 105 1.50 214 2.05 71 210
HXK95AA 15592900 LBP 73 209 129 1.51 258 2.05 89 255
HXK12AA 15593100 LBP 83 245 152 1.50 300 2.04 101 299
HZK95AA 16313100 LBP 73 208 128 1.58 257 2.15 89 254
HZK12AA 16312900 LBP 82 244 152 1.57 299 2.14 101 298
HKK12AT 16173800 LBP 82 245 152 1.42 300 1.97 100 299

R600a • 220-240 V • 50 Hz • KAPPA • Electrical Equipment

Run capacitor (RC) alt. electrics Evaporation tray


Standard
available Terminal
Code PTC / terminal board Terminal
Compressor (protectors, board cover
number E-Starter with external board cover
RC, starters, V0
optional / protector
µF connectors) vertical horizontal
compulsory

HMK80AA 15950000 PTC Z_F5 X


HMK95AA 15460700 PTC Z_F5 X
HMK12AA 16236200 PTC Z_FP X
HTK55AA 16122700 2 optional PTC Z_F0 X
HTK70AA 16106100 3 optional PTC Z_F7 X
HTK80AA 16068300 3 optional PTC Z_FC X
HTK95AA 16068200 4 optional PTC Z_FC X
HTK12AA 16111600 4 optional PTC Z_F9 X
HKK55AA 16124400 2.5 compulsory PTC Z_FF X
HKK70AA 16124500 3 compulsory PTC Z_F6 X
HKK80AA 16072100 3 compulsory PTC Z_F4 X 157595__ 106364__ 113188__
HKK95AA 16049700 4 compulsory PTC Z_FC X
HKK12AA 16065900 4 compulsory PTC Z_FP X
HXK55AA 15650400 3 compulsory E-Starter Z_F6 X
HXK70AA 15690400 3 compulsory E-Starter Z_F6 X
HXK80AA 15621800 3 compulsory E-Starter Z_F4 X
HXK95AA 15592900 4 compulsory E-Starter Z_F5 X
HXK12AA 15593100 4 compulsory E-Starter Z_FP X
HZK95AA 16313100 4 compulsory E-Starter Z_F5 X
HZK12AA 16312900 4 compulsory E-Starter Z_FP X
HKK12AT 16173800 4 compulsory PTC Z_FV X

94

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location / diameter

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C (I.D.) D (O.D.) E (I.D.) F
136 1.51 1/7 8.10 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 1|2|3|6
168 1.55 1/7 9.60 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 1|2|3|6
199 1.54 1/6 11.20 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 1|2|3|6
93 1.55 2* 1/10 5.60 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
118 1.62 3* 1/10 6.60 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
136 1.62 3* 1/8 8.10 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
168 1.65 4* 1/7 9.60 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3
199 1.64 4* 1/5 11.20 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3
94 1.77 2.5 1/10 5.60 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
118 1.80 3 1/10 6.60 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
136 1.80 3 1/8 8.10 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
169 1.81 4 1/7 9.60 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3
198 1.81 4 1/5 11.20 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3
98 1.85 3 1/10 5.60 187-264 V, 50 Hz S 159 165.5 6.15 6.00 5.15 X 1|2|3
119 1.88 3 1/10 6.60 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3|6
141 1.91 3 1/8 8.10 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3|6
172 1.92 4 1/6 9.60 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3|6
203 1.91 4 1/5 11.10 187-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3|6
171 2.01 4 1/6 9.60 187-264 V, 50 Hz S 170 176.5 6.15 6.00 5.15 X 1|2|3|6
202 2.00 4 1/5 11.10 187-264 V, 50 Hz S 170 176.5 6.15 6.00 5.15 X 1|2|3|6
203 1.81 4 1/5 11.10 170-264 V, 50 Hz S 167 173.5 6.15 6.00 5.15 X 1|2|3

KAPPA

95

R600a
R600a • 220-240 V • 50 Hz • DELTA
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
HTD30AA 16250500 LBP 14 62 98 34 1.17 79 1.81 17 76 120
HTD35AA 16250700 LBP 20 73 115 41 1.19 93 1.83 24 90 141
HTD40AA 16250900 LBP 25 86 135 50 1.22 109 1.87 31 106 165
HTD45AA 16251100 LBP 30 104 159 61 1.24 130 1.78 37 127 194
HTD55AA 16251300 LBP 40 126 189 76 1.27 156 1.83 49 154 231
HTD60AA 16255700 LBP 50 144 221 87 1.27 180 1.80 62 176 269
HXD30AA 16260300 LBP 14 62 98 34 1.32 79 2.03 17 76 120
HXD35AA 16260700 LBP 20 73 115 41 1.33 93 2.04 24 90 141
HXD40AA 16261700 LBP 25 86 135 50 1.36 109 2.06 31 106 165
HXD45AA 16261900 LBP 30 104 159 61 1.40 130 2.02 37 127 194
HXD55AA 16257500 LBP 40 126 189 76 1.44 156 2.09 49 154 231
HXD60AA 16302500 LBP 48 145 88 1.43 180 2.04 59 176

R600a • 220-240 V • 50 Hz • DELTA • Electrical Equipment

Run capacitor (RC) Evaporation tray


Standard terminal Terminal board
Code
Compressor PTC / E-Starter board with external cover (small) Adapter plate
number
protector delivered seperately
optional /
µF horizontal
compulsory

HTD30AA 16250500 1 optional PTC B_E7


HTD35AA 16250700 1.5 optional PTC B_E7
HTD40AA 16250900 2 optional PTC B_E6
HTD45AA 16251100 2 optional PTC B_E4
HTD55AA 16251300 2 optional PTC B_E4
HTD60AA 16255700 2 optional PTC B_E4
155471__ 157008__ 162531__
HXD30AA 16260300 1 compulsory E-Starter B_E7
HXD35AA 16260700 1.5 compulsory E-Starter B_E7
HXD40AA 16261700 2 compulsory E-Starter B_E6
HXD45AA 16261900 2 compulsory E-Starter B_E6
HXD55AA 16257500 2 compulsory E-Starter B_E6
HXD60AA 16302500 2 compulsory E-Starter B_E4

96

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location / diameter

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C (I.D.) D (O.D.) E (I.D.) F
46 1.53 101 2.18 1* 1/25 3.00 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9
56 1.55 119 2.19 1.5 * 1/20 3.50 187-264 V, 50 Hz S 133 6.20 6.00 5.00 X 1|2|3|5|6|7|9
68 1.58 140 2.24 2* 1/10 4.00 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9
83 1.60 165 2.11 2* 1/10 4.80 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9
103 1.63 197 2.18 2* 1/10 5.50 187-264 V, 50 Hz S 133 6.20 6.00 5.00 X 1|2|3|5|6|7|9
117 1.63 228 2.13 2* 1/10 6.20 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9
46 1.72 101 2.43 1 1/25 3.00 187-264 V, 50 Hz S 133 6.20 6.00 5.00 X 1|2|3|5|6|7|9
56 1.73 119 2.44 1.5 1/20 3.50 187-264 V, 50 Hz S 133 6.20 6.00 5.00 X 1|2|3|5|6|7|9
68 1.76 140 2.46 2 1/10 4.00 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9
83 1.80 165 2.38 2 1/10 4.80 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9
103 1.85 197 2.49 2 1/10 5.50 187-264 V, 50 Hz S 133 6.20 6.00 5.00 X 1|2|3|5|6|7|9
117 1. 83 2 1/10 6.20 187-264 V, 50 Hz S 133 6.20 6.00 5.00 1|2|3|5|6|7|9

DELTA

97

R600a
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R404A/R507
220-240 V | 50 Hz

T-Series........................................................................................................................................................ 100-101
N-Series........................................................................................................................................................ 102-103
F-Series........................................................................................................................................................ 104-105
S-Series........................................................................................................................................................ 106-109
G-Series........................................................................................................................................................ 110-111

Chemical formula Starting devices


R404A: CHF2CF3 / CH3CF3 / CH2FCF3 LST: Low Starting Torque
R507: CHF2CF3 / CH3CF3 LST is used with capillary tube control and pressure
equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel The PTC starting device requires 5 minutes cooling before
Typelabel stripe colour: Lilac each start.
Typelabel colour: Yellow To fulfil the requirements of EN 60355-2-34 the protection
screen 103N0476 must be applied to the PTC starting device.
Applications HST: High Starting Torque
LBP: Low Back Pressure HST consisting of relay and starting capacitor is used for
HBP: High Back Pressure expansion valve control or for capillary tube control without
MBP: Medium Back Pressure pressure equalizing.
ePTC: Electronically controlled PTC
Motor types • Compressor restart possible after a few seconds
RSIR: Resistant Start Induction Run • Operational wattage loss reduced by 2 watt
RSCR: Resistant Start Capacitor Run • PTC protection screen not needed (surface temp. < 82 °C)
CSIR: Capacitor Start Induction Run • Temperature resistant up to min. +60 °C
CSR: Capacitor Start Run • Additonal information, code numbers: refer to page 18
Test conditons
Compressor cooling Electrical equipment being used is listed in our data sheets
S = Static cooling normally sufficient
O = Oil cooling 1 Watt = 0.86 kcal/h
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 3.41 Btu/h
temp. equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary

98
99
R404A/R507 • 220-240 V • 50 Hz • T-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TL4CL 102U2071 LBP 84 230 352 87 0.80 248 1.19 75 240 391
TL4.5CLX 102U2111 LBP 106 294 107 0.74 318 1.19 102 302
TL4DL 102U2038 M/HBP 229 349 432 631 243 1.14 395 1.38 227 363 455 672

R404A/R507 • 220-240 V • 50 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TL4CL 102U2071 117U6000 117U5014 103N1010 103N2010
TL4.5CLX 102U2111 117U6001 117U5014 103N1010 103N2010
TL4DL 102U2038 117U6001 117U5014 103N1010 103N2010

100

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
152 1.03 317 1.44 1/7 3.86 198-254 V, 50 Hz F2 173 169 6.2 6.2 5.0 4
198 1.05 1/6 4.63 198-254 V, 50 Hz F2 173 169 6.2 6.2 5.0 4|6
293 1.30 531 1.88 1/6 3.86 198-254 V, 50 Hz F2 173 169 6.2 6.2 5.0 10 | 11

TL

101

R404A/R507
R404A/R507 • 220-240 V • 50 Hz • N-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NF7MLX 105F3720 MBP 511 777 940 1336 551 1.29 861 1.58 548 852 1040 1506
NL7CLX 105F3710 LBP 199 536 796 195 0.89 570 1.42 201 577 878
NL8.4CLX 105F3800 LBP 216 583 866 212 0.87 620 1.37 218 627 955
NL6.1MLX 105F3611 MBP 425 650 789 460 1.40 722 1.72 455 712 870

R404A/R507 • 220-240 V • 50 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NF7MLX 105F3720 117U4139 117U5018 117U0349 117U1021
NL7CLX 105F3710 117U6002 117U5015 103N1010 103N2010
NL8.4CLX 105F3800 117U6003 117U5015 103N1010 103N2010
NL6.1MLX 105F3611 117U6022 117U5015 103N1010 103N2011

102

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
695 1.54 1191 2.20 1/2 7.27 187-254 V, 50 Hz * F2 203 197 9.7 6.5 6.5 X 10 | 11
389 1.32 718 1.65 1/3 7.27 198-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 X 4|6
423 1.28 781 1.60 1/2 7.27 198-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 4|6
291 1.14 580 1.67 998 2.40 1/3 6.13 187-254 V, 50 Hz * F2 203 197 8.2 6.5 6.5 10 | 11

NF NL

103

R404A/R507
R404A/R507 • 220-240 V • 50 Hz • F-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
FR6CL 103U2670 LBP 145 383 578 143 0.75 410 1.10 149 394 606
FR7.5CL 103U2790 LBP 154 417 627 155 0.76 447 1.07 158 433 658
FR8.5CL 103U2890 LBP 168 468 173 0.74 501 1.01 171 492 0
FR6DL 103U2680 M/HBP 385 576 698 999 409 1.10 626 1.22 404 600 731 1059

R404A/R507 • 220-240 V • 50 Hz • F-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
FR6CL 103U2670 117U6015 117U5015 103N1010 103N2010
FR7.5CL 103U2790 117U6016 117U5015 103N1010 103N2010
FR8.5CL 103U2890 117U6010 117U5015 103N1010 103N2010
FR6DL 103U2680 117U6010 117U5015 103N1010 103N2010

104

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
268 1.04 494 1.23 1/4 6.23 198-254 V, 50 Hz F2 196 191 8.2 6.2 6.2 X 4
294 1.03 538 1.19 1/4 6.93 198-254 V, 50 Hz F2 196 191 8.2 6.2 6.2 4
333 0.98 1/3 7.95 198-254 V, 50 Hz F2 196 191 8.2 6.2 6.2 X 4
491 1.24 838 1.63 1/4 6.23 198-254 V, 50 Hz F2 196 191 8.2 6.2 6.2 10 | 11

FR

105

R404A/R507
R404A/R507 • 220-240 V • 50 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10CL 104L2523 LBP 168 634 991 183 0.70 694 1.24 132 664 1080
SC12CL 104L2623 LBP 237 835 1292 262 0.78 909 1.32 165 859 1399
SC15CL 104L2853 LBP 299 988 1458 329 0.76 1048 1.26 180 1102 1680
SC18CL 104L2123 LBP 395 1154 1735 405 0.86 1236 1.31 375 1222 1884
SC21CL 104L2322 LBP 455 1306 472 0.87 1393 1.34 442 1388
SC10CLX 104L2533 L/MBP 166 625 977 1190 180 0.65 685 1.28 1096 1.53 130 655 1065 1318
SC12CLX.2 104L2697 LBP 294 834 298 0.79 890 1.28 278 900
SC15CLX.2 104L2896 LBP 358 1017 364 0.81 1086 1.32 339 1098
SC18CLX.2 104L2197 LBP 439 1245 446 0.83 1329 1.33 415 1345
SC10DL 104L2525 M/HBP 611 968 1192 1747 2085 673 1.33 1100 1.64 645 1053 1302 1919 2299
SC12DL 104L2625 M/HBP 806 1279 1565 2258 2674 892 1.36 1441 1.70 866 1409 1731 2512 2989
SC15DL 104L2856 M/HBP 964 1493 1825 2652 3156 1047 1.38 1682 1.71 1036 1643 2015 2933 3498
SC15DLX.2 104L2871 M/HBP 983 1504 1824 2604 3071 1063 1.37 1669 1.70 1056 1648 2012 2912 3464
SC10MLX 104L2506 MBP 687 1051 1278 742 1.36 1162 1.64 723 1129 1382
SC12MLX 104L2606 MBP 838 1272 1542 900 1.38 1401 1.64 887 1371 1673
SC15MLX 104L2869 MBP 1038 1574 1909 1114 1.36 1752 1.61 1119 1720 2105
SC18MLX 104L2139 MBP 1210 1832 2220 1299 1.43 2037 1.70 1307 2004 2450
SC18MLX.3 104L2146 MBP 1266 1898 2292 1351 1.46 2109 1.71 1386 2100 2556
SC10/10CL 104L4087 LBP 336 1268 1981 365 0.70 1389 1.24 264 1329 2160
SC12/12CL 104L4088 LBP 475 1670 2583 524 0.78 1818 1.32 331 1717 2798
SC15/15CL 104L4089 LBP 599 1976 2916 657 0.76 2097 1.26 361 2205 3361
SC18/18CL 104L4090 LBP 789 2307 3469 810 0.86 2472 1.31 749 2443 3768
SC21/21CL 104L4094 LBP 910 2613 945 0.87 2787 1.34 885 2776

R404A/R507 • 220-240 V • 50 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10CL 104L2523 117U6003 117U5017 103N1004 103N2009
SC12CL 104L2623 117U6005 117U5017 103N1004 103N2009
SC15CL 104L2853 117U6019 117U5017 103N1004 103N2009
SC18CL 104L2123 117U5373 117-7027 103N1004 103N2009
SC21CL 104L2322 117U5373 117-7027 103N1004 103N2009
SC10CLX 104L2533 117U6005 117U5017 103N1004 103N2008
SC12CLX.2 104L2697 117U6019 117U5017 103N1004 103N2008
SC15CLX.2 104L2896 117U6019 117U5017 103N1004 103N2009
SC18CLX.2 104L2197 117U6013 117U5012 103N1004 103N2009
SC10DL 104L2525 117U6005 117U5017 103N1004 103N2009
SC12DL 104L2625 117U6019 117U5017 103N1004 103N2009
SC15DL 104L2856 117U5373 117-7029 103N1004 103N2009
SC15DLX.2 104L2871 117U6019 117U5017 103N1004 103N2009
SC10MLX 104L2506 117U6011 117U5017 103N1004 103N2008
SC12MLX 104L2606 117U6011 117U5017 103N1004 103N2008
SC15MLX 104L2869 117U6013 117U5012 103N1004 103N2009
SC18MLX 104L2139 117U5373 117-7027 103N1004 103N2009
SC18MLX3 104L2146 117-7027 103N1004 103N2009
SC10/10CL 104L4087 117U6003 117U5017 103N1004 103N2009
SC12/12CL 104L4088 117U6005 117U5017 103N1004 103N2009
SC15/15CL 104L4089 117U6019 117U5017 103N1004 103N2009
SC18/18CL 104L4090 117-7027 103N1004 103N2009
SC21/21CL 104L4094 117U5373 117-7027 103N1004 103N2009

106

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
402 1.13 876 1.50 1/2 10.29 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 X 4|6
517 1.10 1135 1.55 1/2 12.87 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 X 4|6
698 1.20 1377 1.55 3/4 15.28 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 4
804 1.22 1539 1.55 10 3/4 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 4
906 1.18 10 1 20.95 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 4
397 1.11 864 1.56 1/3 10.29 198-254 V, 50 Hz * F2 209 203 8.2 6.2 6.2 X 4|6
594 1.15 1/2 12.87 198-254 V, 50 Hz * F2 219 213 8.2 6.2 6.2 X 4|6
725 1.18 3/4 15.28 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 4|6
887 1.20 3/4 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 4|6
854 1.56 1512 2.24 1/2 10.29 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 X 10 | 11
1145 1.62 1987 2.35 3/4 12.87 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 10 | 11
1338 1.61 2317 2.34 10 3/4 15.28 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 10 | 11
1344 1.65 2304 2.36 3/4 15.28 198-254 V, 50 Hz F2 219 213 10.2 6.2 8.2 10 | 11
920 1.59 1588 2.27 1/2 10.29 187-254 V, 50 Hz * F2 209 203 8.2 6.5 6.5 10 | 11
585 1.15 1119 1.61 1916 2.26 3/4 12.87 187-254 V, 50 Hz * F2 219 213 8.2 6.5 6.5 10 | 11
763 1.20 1403 1.61 2425 2.24 3/4 15.28 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 10 | 11
895 1.27 1636 1.70 2820 2.36 10 1 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 10 | 11
960 1.34 1717 1.73 2928 2.37 10 1 17,68 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 10 | 11
804 1.13 1753 1.50 3/4 20.58 198-254 V, 50 Hz F2 249 244 12.0 6.2 6.2 4
1034 1.10 2269 1.55 1 25.74 198-254 V, 50 Hz F2 249 244 12.0 6.2 6.2 4
1396 1.20 2754 1.55 1 1/4 30.56 198-254 V, 50 Hz F2 259 254 12.0 6.2 6.2 X 4
1608 1.22 3077 1.55 10 1 1/2 35.38 198-254 V, 50 Hz F2 259 254 16.0 6.2 6.2 4
1812 1.18 10 1 3/4 41.90 198-254 V, 50 Hz F2 259 254 16.0 6.2 6.2 4

SC SC-Twin

107

R404A/R507
R404A/R507 • 220-240 V • 50 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10/10DL 104L4091 M/HBP 1222 1935 2383 3494 4169 1345 1.33 2199 1.64 1290 2105 2604 3838 4597
SC12/12DL 104L4092 M/HBP 1612 2559 3130 4516 5348 1783 1.36 2883 1.70 1732 2817 3461 5024 5978
SC15/15DL 104L4093 M/HBP 1928 2985 3651 5304 6311 2094 1.38 3364 1.71 2071 3286 4029 5865 6995
SCE18CLX.2 104L2196 LBP 439 1245 446 0.93 1329 1.42 415 1345
SLV12CLK.2, 2000 rpm 104L2603 LBP 196 572 200 0.86 612 1.42 179 624
SLV12CLK.2, 2500 rpm 104L2603 LBP 243 742 254 0.89 790 1.45 201 805
SLV12CLK.2, 3000 rpm 104L2603 LBP 283 895 301 0.90 948 1.47 217 965
SLV12CLK.2, 4000 rpm 104L2603 LBP 370 1114 388 0.87 1162 1.51 335 1228

R404A/R507 • 220-240 V • 50 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10/10DL 104L4091 117U6005 117U5017 103N1004 103N2009
SC12/12DL 104L4092 117U6019 117U5017 103N1004 103N2009
SC15/15DL 104L4093 117U5373 117-7029 103N1004 103N2009
SCE18CLX.2 104L2196 117U5373 117-7027 103N1004 103N2009
SLV12CLK.2 104L2603 105N46xx series controller 103N2008

108

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
1708 1.56 3023 2.24 1 20.58 198-254 V, 50 Hz F2 249 244 12.0 6.2 6.2 10 | 11
2290 1.63 3974 2.35 1 1/4 25.74 198-254 V, 50 Hz F2 259 254 12.0 6.2 6.2 10 | 11
2676 1.61 4633 2.33 10 1 1/2 30.56 198-254 V, 50 Hz F2 259 254 16.0 6.2 6.2 10 | 11
887 1.31 10 3/4 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 4
405 1.19 3/4 12.87 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6
512 1.27 3/4 12.87 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6
605 1.32 3/4 12.87 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6
844 1.33 3/4 12.87 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6

SC-Twin SLV

109

R404A/R507
R404A/R507 • 220-240 V • 50 Hz • G-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
GS26CLX 107B0500 LBP 689 2036 703 1.05 2191 1.65 662 2186
GS34CLX 107B0501 LBP 1007 2816 4238 1003 1.09 3014 1.69 1016 3116 4808
GS21MLX 107B0502 MBP 1599 2508 3092 1748 1.81 2858 2.23 1711 2709 3358
GS26MLX 107B0503 MBP 2078 3204 3911 2254 1.86 3615 2.24 2243 3519 4325
GS34MLX 107B0504 MBP 2764 4143 4998 2953 1.71 4580 1.97 2998 4554 5527

R404A/R507 • 220-240 V • 50 Hz • G-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm
GS26CLX 107B0500 117-7056 107B9101
GS34CLX 107B0501 117-7074 107B9101
GS21MLX 107B0502 117-7070 107B9101
GS26MLX 107B0503 117-7072 107B9101
GS34MLX 107B0504 117-7056 107B9101

110

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
1297 1.39 20 1 1/4 26.30 198-254 V, 50 Hz F2 259 247 12.9 6.5 8.2 4
1880 1.49 3924 2.07 10 1 3/4 33.80 198-254 V, 50 Hz F2 279 267 12.9 6.5 8.2 X 4
2200 2.12 3954 3.09 20 1 1/4 21.20 198-254 V, 50 Hz F2 259 247 16.1 6.5 9.7 10 | 11
2866 2.20 5027 3.12 20 1 1/2 26.30 198-254 V, 50 Hz F2 279 267 16.1 6.5 9.7 10 | 11
3726 2.03 6330 2.74 20 1 3/4 33.80 198-254 V, 50 Hz F2 279 267 16.1 6.5 9.7 10 | 11

GS

Note:
On GS34CLX
compressors
suction and
process
connectors are
interchanged.

111

R404A/R507
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R290
220-240 V | 50 Hz

T-Series........................................................................................................................................................ 114-115
D-Series........................................................................................................................................................ 116-117
N-Series........................................................................................................................................................ 118-119
S-Series........................................................................................................................................................ 120-121

Chemical formula Starting devices


C3H8 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Red The PTC starting device requires 5 minutes cooling before
Typelabel colour: Yellow each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

112
113
R290 • 220-240 V • 50 Hz • T-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TL3CN 102H4380 L/MBP 54 161 244 294 55 0.59 177 1.25 281 1.57 49 161 249 304
TL4CN 102H4490 L/MBP 78 205 302 360 78 0.74 222 1.30 344 1.63 76 212 316 380
TL5CN 102H4590 L/MBP 109 283 416 496 108 0.80 306 1.38 472 1.60 109 296 437 522

R290 • 220-240 V • 50 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TL3CN 102H4380 103N0011 103N0018 117U7004 117U5014 103N1010 103N2010
TL4CN 102H4490 103N0011 103N0018 117U7004 117U5014 103N1010 103N2010
TL5CN 102H4590 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 117U7000 117U5014 103N1010 103N2010

114

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
105 0.91 212 1.42 1/10 3.13 198-254 V, 50 Hz F1 163 159 6.2 6.2 5.0 3|4|6|10|11
146 1.07 270 1.51 1/8 3.86 198-254 V, 50 Hz F1 173 169 6.2 6.2 5.0 3|4|6|10|11
205 1.18 374 1.58 * 1/5 5.08 198-254 V, 50 Hz F1 173 169 6.2 6.2 5.0 X 3|4|6|10|11

TL

115

R290
R290 • 220-240 V • 50 Hz • D-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
DLE4CN 102H4465 L/MBP 101 261 375 438 100 1.01 280 1.79 411 2.13 103 277 401 469
DLE4.8CN 102H4565 L/MBP 107 311 456 547 106 0.88 335 1.75 539 2.25 128 339 495 596
DLE5.7CN 102H4653 L/MBP 162 385 558 667 155 1.07 412 1.76 650 2.18 168 415 604 723
DLE6.5CN 102H4765 L/MBP 165 414 608 731 160 1.04 446 1.75 709 2.13 168 446 653 784
DLE7.5CN 102H4853 L/MBP 202 490 718 858 194 1.04 528 1.75 828 2.08 209 520 766 920

R290 • 220-240 V • 50 Hz • D-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
DLE4CN 102H4465 103N0050 117-7129 117U7000 117U5014 103N1010 103N0491
DLE4.8CN 102H4565 103N0050 117-7129 117U7001 117U5014 103N1010 103N0491
DLE5.7CN 102H4653 103N0050 117-7129 117U7015 117U5015 103N1010 103N0491
DLE6.5CN 102H4765 103N0050 117-7129 117U7016 117U5015 103N1010 103N0491
DLE7.5CN 102H4853 103N0050 117-7129 117U7002 117U5015 103N1010 103N0491

116

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
191 1.48 345 2.03 522 2.69 * 1/6 4.00 198-254 V, 50 Hz F2 175 169 6.2 6.2 5.0 3|4|6|7|10|11
243 1.56 423 2.04 708 2.91 * 1/4 4.80 198-254 V, 50 Hz F2 175 169 8.2 6.2 6.2 3|4|6|7|10|11
298 1.53 517 2.03 850 2.80 * 1/4 5.70 198-254 V, 50 Hz F2 175 169 8.2 6.2 6.2 X 3|4|6|7|10|11
316 1.53 559 1.98 921 2.71 * 1/3 6.50 198-254 V, 50 Hz F2 175 169 8.2 6.2 6.2 3|4|6|7|10|11
367 1.47 656 1.97 1077 2.65 * 1/3 7.48 198-254 V, 50 Hz F2 175 169 8.2 6.2 6.2 X 3|4|6|7|10|11

DLE

117

R290
R290 • 220-240 V • 50 Hz • N-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54,4°C, Tliq=32,2°C, Tsuc=32,2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NL7CN 105H6756 L/MBP 166 458 679 814 166 0.91 498 1.63 782 1.90 175 475 713 860
NL9CN 105H6856 L/MBP 194 526 778 930 192 0.94 571 1.62 890 1.88 205 549 816 981
NLE8.8CN 105H6880 L/MBP 248 576 838 1001 1400 237 1.12 619 1.80 964 2.20 236 612 895 1069 1499
NLE10CN 105H6175 L/MBP 274 669 978 1164 1603 265 1.10 721 1.73 1115 2.08 268 703 1039 1242 1724
NLE11CNL 105H6174 LBP 291 734 1066 283 1.05 790 1.72 301 779 1145

R290 • 220-240 V • 50 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NL7CN 105H6756 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 117U7002 117U5015 103N1010 103N2010
NL9CN 105H6856 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 117U7002 117U5015 103N1010 103N2010
NLE8.8CN 105H6880 103N0050 117U7002 117U5015 103N1010 103N2010
NLE10CN 105H6175 103N0050 117U7002 117U5015 103N1010 103N2010
NLE11CNL 105H6174 103N0050 117U7003 117U5015 103N1010 103N2010

118

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
326 1.35 609 1.87 * 1/2 7.27 198-254 V, 50 Hz F1 203 197 8.2 6.2 6.2 X 3|4|6|10|11
380 1.39 698 1.86 * 1/2 8.35 198-254 V, 50 Hz F1 203 197 8.2 6.2 6.2 X 3|4|6|10|11
431 1.57 766 2.04 1246 2.78 1/2 8.76 198-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 3|4|6|10|11
487 1.47 889 1.95 1439 2.62 1/2 10.09 198-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 3|4|6|10|11
541 1.52 981 1.98 1/2 11.15 198-254 V, 50 Hz F2 203 197 8.2 6.2 6.2 4 | 6 | 10

NL NLE

119

R290
R290 • 220-240 V • 50 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10CNX 104H8065 L/MBP 179 531 809 979 183 0.82 586 1.54 953 2.02 176 548 854 1044
SC12CNX 104H8265 L/MBP 250 678 1050 1293 251 0.89 751 1.57 1279 2.00 227 712 1112 1374
SC15CNX 104H8565 L/MBP 297 887 1328 1594 311 0.92 970 1.65 1549 1.93 252 919 1417 1719
SC18CNX 104H8865 L/MBP 341 1033 1543 1849 352 0.89 1129 1.52 1806 1.72 316 1107 1686 2034
SC12CNX.2 104H8266 LBP 258 725 260 0.85 794 1.50 231 743
SC15CNX.2 104H8566 LBP 332 900 327 0.89 993 1.55 346 929
SC18CNX.2 104H8866 LBP 384 1057 399 0.90 1130 1.58 343 1195
SC21CNX.2 104H8166 LBP 492 1233 502 0.97 1305 1.45 463 1401
SC10MNX 104H8075 MBP 567 883 1074 634 1.51 1043 2.04 576 922 1133
SC12MNX 104H8275 MBP 741 1127 1361 817 1.57 1330 2.06 758 1196 1463
SC15MNX 104H8575 MBP 887 1322 1586 966 1.56 1512 1.96 968 1411 1681
SC18MNX 104H8875 MBP 1035 1506 1798 1112 1.48 1747 1.85 1110 1624 1946
SLV15CNK.2 2000 rpm 104H8541 LBP 236 638 234 0.99 697 1.65 232 665
SLV15CNK.2 2500 rpm 104H8541 LBP 297 805 296 1.01 878 1.69 291 842
SLV15CNK.2 3000 rpm 104H8541 LBP 353 941 350 1.02 1021 1.70 360 981
SLV15CNK.2 4000 rpm 104H8541 LBP 460 1228 459 1.00 1325 1.64 439 1299

R290 • 220-240 V • 50 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10CNX 104H8065 117U5372 117-7025 117-9719 103N1004 103N2009
SC12CNX 104H8265 117U5372 117-7025 117-9719 103N1004 103N2009
SC15CNX 104H8565 117U5373 117-7031 117-9711 103N1004 103N2009
SC18CNX 104H8865 117U5373 117-7052 117-9718 103N1004 103N2009
SC12CNX.2 104H8266 117U7003 117U5017 103N1004 103N2009
SC15CNX.2 104H8566 117U7005 117U5017 103N1004 103N2009
SC18CNX.2 104H8866 117U7011 117U5017 103N1004 103N2009
SC21CNX.2 104H8166 117U7013 117U5012 103N1004 103N2009
SC10MNX 104H8075 117U7005 117U5017 103N1004 103N2008
SC12MNX 104H8275 117U7019 117U5017 103N1004 103N2008
SC15MNX 104H8575 117U7019 117U5017 103N1004 103N2008
SC18MNX 104H8875 117U7011 117U5017 103N1004 103N2008
SLV15CNK.2 104H8541 105N46xx series controller 103N2008

120

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
359 1.27 725 1.84 5 1/3 10.29 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 3|4|6|10|11
475 1.31 941 1.85 5 1/2 12.87 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 X 3|4|6|10|11
597 1.36 1206 1.89 10 1/2 15.28 198-254 V, 50 Hz F2 209 203 10.2 6.2 6.2 X 3|4|6|10|11
728 1.36 1438 1.80 10 3/4 17.69 198-254 V, 50 Hz F2 209 203 10.2 6.2 6.2 X 3|4|6|10|11
491 1.20 1/2 12.87 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 4|6
625 1.32 3/4 15.28 198-254 V, 50 Hz F2 209 203 10.2 6.2 6.2 4|6
798 1.31 3/4 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 4|6
963 1.46 10 1 20.95 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 4
352 1.20 781 1.75 1357 2.66 1/2 10.29 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 3 | 7 | 10 | 11
475 1.13 1015 1.83 1744 2.71 1/2 12.87 198-254 V, 50 Hz F2 219 213 8.2 6.2 6.2 3 | 7 | 10 | 11
681 1.51 1210 1.80 1948 2.48 3/4 15.28 198-254 V, 50 Hz F2 219 213 8.2 6.2 6.2 3 | 7 | 10 | 11
778 1.31 1391 1.76 2284 2.41 3/4 17.69 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 3 | 7 | 10 | 11
446 1.32 3/4 15.28 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6
566 1.43 3/4 15.28 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6
675 1.44 3/4 15.28 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6
889 1.42 3/4 15.28 180-254 V, 50 Hz * F2 199 193 10.2 6.2 6.2 4|6

SC SLV

121

R290
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R407C
220-240 V | 50 Hz

S-Series........................................................................................................................................................ 124-125

Chemical formula Starting devices


CH2F2 / CHF2CF3 / CH2FCF3 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Red The PTC starting device requires 5 minutes cooling before
Typelabel colour: Yellow each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

122
123
R407C • 220-240 V • 50 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10DL 104L2525 M/HBP 611 968 1192 1747 2085 673 1.33 1100 1.64 645 1053 1302 1919 2299
SC12DL 104L2625 M/HBP 806 1279 1565 2258 2674 892 1.36 1441 1.70 866 1409 1731 2512 2989
SC15DL 104L2856 M/HBP 964 1493 1825 2652 3156 1047 1.38 1682 1.71 1036 1643 2015 2933 3498
SC10/10DL 104L4091 M/HBP 1222 1935 2383 3494 4169 1345 1.33 2199 1.64 1290 2105 2604 3838 4597
SC12/12DL 104L4092 M/HBP 1612 2559 3130 4516 5348 1783 1.36 2883 1.70 1732 2817 3461 5024 5978
SC15/15DL 104L4093 M/HBP 1928 2985 3651 5304 6311 2094 1.38 3364 1.71 2071 3286 4029 5865 6995

R407C • 220-240 V • 50 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10DL 104L2525 117U6005 117U5017 103N1004 103N2009
SC12DL 104L2625 117U6019 117U5017 103N1004 103N2009
SC15DL 104L2856 117U5373 117-7029 103N1004 103N2009
SC10/10DL 104L4091 117U6005 117U5017 103N1004 103N2009
SC12/12DL 104L4092 117U6019 117U5017 103N1004 103N2009
SC15/15DL 104L4093 117U5373 117-7029 103N1004 103N2009

124

R407C
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
854 1.56 1512 2.24 1/2 10.29 198-254 V, 50 Hz F2 209 203 8.2 6.2 6.2 X 10 | 11
1145 1.62 1987 2.35 3/4 12.87 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 10 | 11
1338 1.61 2317 2.34 10 3/4 15.28 198-254 V, 50 Hz F2 219 213 10.2 6.2 6.2 X 10 | 11
1708 1.56 3023 2.24 1 20.58 198-254 V, 50 Hz F2 249 244 12.0 6.2 6.2 10 | 11
2290 1.63 3974 2.35 1 1/4 25.74 198-254 V, 50 Hz F2 259 254 12.0 6.2 6.2 10 | 11
2676 1.61 4633 2.33 10 1 1/2 30.56 198-254 V, 50 Hz F2 259 254 16.0 6.2 6.2 10 | 11

SC SC-Twin

125

R407C
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R134a
220-240 V | 60 Hz

T-Series........................................................................................................................................................ 128-129
N-Series........................................................................................................................................................ 130-131
F-Series........................................................................................................................................................ 132-133
S-Series........................................................................................................................................................ 134-135

Chemical formula Starting devices


CH2FCF3 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Blue The PTC starting device requires 5 minutes cooling before
Typelabel colour: Yellow each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

126
127
R134a • 220-240 V • 60 Hz • T-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TL2.5G 102G4251 L/M/HBP 14 80 134 168 253 306 42 0.62 105 1.09 208 1.58 18 100 167 210 317 383
TL3G 102G4350 LBP 95 161 47 0.68 125 1.13 118 200
TL4G 102G4452 LBP 127 211 70 0.80 166 1.23 158 261
TL4G 102G4458 LBP 127 211 70 0.80 166 1.23 158 261
TL5G 102G4550 LBP 162 260 91 0.87 207 1.22 200 322
TL4GH 102G4455 HBP 118 208 264 403 489 160 1.15 328 1.70 149 260 329 503 611

R134a • 220-240 V • 60 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TL2.5G 102G4251 103N0011 103N0018 117U6007 117U5014 103N1010 103N2011
TL3G 102G4350 103N0011 103N0018 117U6009 117U5014 103N1010 103N2010
TL4G 102G4452 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010
TL4G 102G4458 103N0011 103N0018 117U6004 117U5014 103N1010 103N2011
TL5G 102G4550 103N0011 103N0018 117U6000 117U5014 103N1010 103N2010
TL4GH 102G4455 117U6000 117U5014 103N1010 103N2011

128

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
60 0.85 140 1.37 258 1.92 1/10 2.61 198-254 V, 60 Hz * S 163 159 6.2 6.2 5.0 X 3 | 10 | 11
68 0.93 167 1.39 1/10 3.13 198-254 V, 60 Hz * S 163 159 6.2 6.2 5.0 X 6 | 10
97 1.06 220 1.53 1/10 3.86 198-254 V, 60 Hz * S 173 169 6.2 6.2 5.0 X 6 | 10
97 1.06 220 1.53 1/10 3.86 198-254 V, 60 Hz * S 173 169 6.5 6.5 5.0 X 6 | 10
126 1.13 272 1.49 1/8 5.08 198-254 V, 60 Hz * S 173 169 6.2 6.2 5.0 X 6 | 10
217 1.47 409 2.06 1/8 3.86 198-254 V, 60 Hz * F2 173 169 6.2 6.2 5.0 8

TL

129

R134a
R134a • 220-240 V • 60 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NF7FX 105G6743 L/MBP 313 489 602 187 0.91 393 1.35 734 1.96 387 606 746
NF10FX 105G6846 L/MBP 363 569 706 223 0.89 456 1.28 870 1.79 448 705 876
NL6FT 105G6628 LBP 59 199 119 0.94 251 1.40 73 247
NL6.1MF 105G6660 L/MBP 43 223 374 470 117 0.89 292 1.34 581 1.90 55 278 465 585
NL7.3MF 105G6772 L/MBP 73 283 458 570 159 0.92 363 1.32 700 1.85 92 352 570 709
NL8.4MF 105G6879 L/MBP 77 325 532 664 179 0.95 420 1.35 818 1.87 96 404 662 827
NL10MF 105G6885 L/MBP 109 406 650 807 233 1.00 518 1.39 989 1.91 136 503 807 1002

R134a • 220-240 V • 60 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NF7FX 105G6743 117U4140 117U5018 117U0349 117U1023
NF10FX 105G6846 117U4139 117U5018 117U0349 117U1023
NL6FT 105G6628 103N0011 103N0018 117U6000 117U5015 103N1010 103N2010
NL6.1MF 105G6660 103N0011 103N0018 117U6015 117U5015 103N1010 103N2011
NL7.3MF 105G6772 103N0011 103N0018 117U6016 117U5015 103N1010 103N2011
NL8.4MF 105G6879 103N0011 103N0018 117U6016 117U5018 103N1010 103N2011
NL10MF 105G6885 103N0011 103N0018 117U6022 117U5018 103N1010 103N2011

130

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
254 1.18 512 1.68 903 2.37 1/4 7.27 198-242 V, 60 Hz* F1 203 197 8.2 6.5 6.5 X 3
300 1.14 595 1.58 1078 2.15 1/3 10.09 198-242 V, 60 Hz * F2 203 197 8.2 6.5 6.5 X 3
162 1.22 1/7 6.13 198-254 V, 60 Hz * S 197 191 6.2 6.2 5.0 3
165 1.17 390 1.67 722 2.31 1/5 6.13 187-254 V, 60 Hz * S 190 184 8.2 6.2 6.2 X 3
221 1.19 480 1.64 865 2.24 1/4 7.27 187-254 V, 60 Hz * F1 197 191 8.2 6.2 6.2 X 3
249 1.24 556 1.67 1013 2.27 1/3 8.35 187-254 V, 60 Hz * F1 197 191 8.2 6.2 6.2 X 3
320 1.29 681 1.71 1221 2.31 1/3 10.09 187-254 V, 60 Hz * F1 203 197 8.2 6.2 6.2 X 3

NF NL

131

R134a
R134a • 220-240 V • 60 Hz • F-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
FR6G 103G6660 LBP 199 345 92 0.78 266 1.35 247 428
FR7.5G 103G6680 LBP 228 385 112 0.81 300 1.31 282 477
FR7.5G 103G6690 LBP 228 385 112 0.81 300 1.31 282 477
FR8.5G 103G6780 LBP 263 441 138 0.85 345 1.26 327 547
FR8.5G 103G6790 LBP 263 441 138 0.85 345 1.26 327 547
FR10G 103G6880 LBP 292 486 153 0.79 381 1.21 362 602
FR10G 103G6890 LBP 292 486 153 0.79 381 1.21 362 602
FR7GH 103G6683 HBP 225 379 482 753 924 294 1.35 607 1.91 279 471 600 940 1155
FR7GH 103G6692 HBP 225 379 482 753 924 294 1.35 607 1.91 279 471 600 940 1155

R134a • 220-240 V • 60 Hz • F-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
FR6G 103G6660 103N0011 103N0018 117U6000 117U5015 103N1010 103N2010
FR7.5G 103G6680 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
FR7.5G 103G6690 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
FR8.5G 103G6780 103N0011 103N0018 117U6015 117U5015 103N1010 103N2010
FR8.5G 103G6790 103N0011 103N0018 117U6015 117U5015 103N1010 103N2010
FR10G 103G6880 103N0011 103N0018 117U6010 117U5015 103N1010 103N2010
FR10G 103G6890 103N0011 103N0018 117U6010 117U5015 103N1010 103N2010
FR7GH 103G6683 117U6016 117U5015 103N1010 103N2011
FR7GH 103G6692 117U6016 117U5015 103N1010 103N2011

132

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
135 1.06 357 1.69 1/8 6.23 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 6 | 10
161 1.09 399 1.62 1/7 6.93 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 X 4 | 6 | 10
161 1.09 399 1.62 1/7 6.93 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 6.2 4 | 6 | 10
194 1.11 459 1.55 1/6 7.95 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 4 | 6 | 10
194 1.11 459 1.55 1/6 7.95 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 6.2 4 | 6 | 10
215 1.05 505 1.49 1/5 9.05 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 X 4 | 6 | 10
215 1.05 505 1.49 1/5 9.05 198-254 V, 60 Hz * F1 196 191 8.2 6.2 6.2 6.2 4 | 6 | 10
393 1.67 758 2.33 1/4 6.93 198-254 V, 60 Hz * F2 196 191 8.2 6.2 8.2 8
393 1.67 758 2.33 1/4 6.93 198-254 V, 60 Hz * F2 196 191 8.2 6.2 8.2 8.2 8

FR

133

R134a
R134a • 220-240 V • 60 Hz • S-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC12FT 104G8205 LBP 125 477 761 272 0.91 608 1.33 156 592 947
SC12FT 104G8215 LBP 125 477 761 272 0.91 608 1.33 156 592 947
SC15FT 104G8505 LBP 154 571 904 330 0.92 724 1.35 192 709 1124
SC18FTX 104G8805 LBP 187 675 1071 390 0.93 857 1.38 234 838 1333
SC21FTX 104G8106 LBP 240 800 1262 470 0.99 1012 1.43 298 991 1565
SC10G 104G8000 LBP 27 314 569 132 0.63 432 1.27 35 390 706
SC12G 104G8240 LBP 74 406 704 203 0.77 542 1.31 93 505 876
SC12G 104G8245 MBP 370 696 907 1449 519 1.34 1157 2.07 461 866 1130 1808
SC12G 104G8250 LBP 74 406 704 203 0.77 542 1.31 93 505 876
SC15G 104G8520 LBP 515 863 262 0.79 677 1.34 640 1071
SC15G 104G8526 MBP 468 834 1049 1567 641 1.37 1292 2.01 583 1037 1305 1956
SC18G 104G8823 MBP 573 955 1207 1858 745 1.46 1506 2.13 712 1188 1502 2318
SC18G 104G8820 LBP 623 1021 338 0.88 807 1.31 772 1266
SC18G 104G8830 LBP 623 1021 338 0.88 807 1.31 772 1266
SC21G 104G8140 LBP 655 1145 303 0.80 880 1.36 816 1421
SC10GH 104G8041 HBP 318 541 683 1042 1265 421 1.24 849 1.71 400 676 854 1305 1586
SC12GH 104G8261 HBP 371 680 880 1393 1714 511 1.31 1116 2.01 462 845 1095 1737 2141
SC15GH 104G8561 HBP 425 776 1012 1629 2019 582 1.37 1295 2.03 525 964 1259 2032 2523
SC18GH 104G8861 HBP 573 955 1207 1858 2268 745 1.46 1506 2.13 712 1188 1502 2318 2834
SC18MFX 104G8804 MBP 668 1067 1322 1968 851 1.45 1621 2.03 827 1324 1642 2451

R134a • 220-240 V • 60 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC12FT 104G8205 103N0011 117U6003 117U5017 103N1004 103N2009
SC12FT 104G8215 103N0011 117U6003 117U5017 103N1004 103N2009
SC15FT 104G8505 103N0011 117U6005 117U5017 103N1004 103N2009
SC18FTX 104G8805 117U6019 117U5017 103N1004 103N2009
SC21FTX 104G8106 117U5373 117-7039 103N1004 103N2008
SC10G 104G8000 103N0011 117U6002 117U5017 103N1004 103N2009
SC12G 104G8240 103N0011 117U6003 117U5017 103N1004 103N2008
SC12G 104G8245 117U6011 117U5017 103N1004 103N2008
SC12G 104G8250 103N0011 117U6003 117U5017 103N1004 103N2009
SC15G 104G8520 117U6005 117U5017 103N1004 103N2009
SC15G 104G8526 117U6011 117U5017 103N1004 103N2008
SC18G 104G8823 117U5373 117-7039 103N1004 103N2008
SC18G 104G8820 117U6019 117U5017 103N1004 103N2009
SC18G 104G8830 117U6019 117U5017 103N1004 103N2009
SC21G 104G8140 117U5373 117-7029 103N1004 103N2009
SC10GH 104G8041 117U6005 117U5017 103N1004 103N2008
SC12GH 104G8261 117U6011 117U5017 103N1004 103N2008
SC15GH 104G8561 117U6011 117U5017 103N1004 103N2008
SC18GH 104G8861 117U5373 117-7039 103N1004 103N2008
SC18MFX 104G8804 117-7027 103N1004 103N2008

134

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
375 1.19 799 1.64 1/3 12.87 198-254 V, 60 Hz * F1 209 203 8.2 6.2 6.2 X 4 | 6 | 10
375 1.19 799 1.64 1/3 12.87 198-254 V, 60 Hz * F1 209 203 8.2 6.2 6.2 6.2 X 4 | 6 | 10
453 1.20 950 1.67 1/2 15.28 198-254 V, 60 Hz * F2 209 203 10.2 6.2 6.2 X 4 | 10
536 1.21 1125 1.72 1/2 17.69 198-254 V, 60 Hz * F2 219 213 10.2 6.2 6.2 X 4 | 10
642 1.29 1322 1.74 10 3/4 20.95 187-254 V, 60 Hz F2 219 213 10.2 6.2 6.2 X 4 | 10
197 0.87 588 1.64 1/6 10.29 198-254 V, 60 Hz * F2 199 193 8.2 6.2 6.2 X 4 | 6 | 10
289 1.03 731 1.65 1/4 12.87 198-254 V, 60 Hz * F2 209 203 8.2 6.2 6.2 X 4 | 6 | 10
716 1.70 1451 2.54 1/2 12.87 187-254 V, 60 Hz F2 209 203 10.2 6.5 6.5 X 3
289 1.03 731 1.65 1/4 12.87 198-254 V, 60 Hz * F2 209 203 8.2 6.2 6.2 6.2 X 4 | 6 | 10
372 1.07 900 1.69 1/3 15.28 198-254 V, 60 Hz * F2 209 203 10.2 6.2 6.2 X 4 | 10
866 1.72 1597 2.46 1/2 15.28 187-254 V, 60 Hz F2 209 203 10.2 6.5 6.5 X 3
994 1.82 1876 2.59 10 3/4 17.69 187-254 V, 60 Hz F2 219 213 10.2 6.5 6.5 X 3
469 1.13 1064 1.63 1/2 17.69 198-254 V, 60 Hz * F2 219 213 10.2 6.2 6.2 X 4 | 10
469 1.13 1064 1.63 1/2 17.69 198-254 V, 60 Hz * F2 219 213 10.2 6.2 6.2 6.2 X 4 | 10
446 1.08 1186 1.72 10 1/2 20.95 198-254 V, 60 Hz * F2 219 213 10.2 6.2 6.2 X 4 | 10
566 1.53 1059 2.09 1/3 10.29 198-254 V, 60 Hz * F2 209 203 10.2 6.2 8.2 X 8
700 1.67 1398 2.46 1/2 12.87 198-254 V, 60 Hz * F2 209 203 10.2 6.2 8.2 X 8
797 1.72 1627 2.47 1/2 15.28 198-254 V, 60 Hz * F2 209 203 10.2 6.2 8.2 X 8
994 1.82 1876 2.59 10 3/4 17.69 198-254 V, 60 Hz * F2 219 213 10.2 6.2 8.2 X 8
529 1.26 1116 1.80 2000 2.45 10 3/4 17.69 187-254 V, 60 Hz * F2 219 213 10.2 6.2 6.2 3 | 10 | 11

SC

135

R134a
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R404A/R507
220-240 V | 60 Hz

N-Series........................................................................................................................................................ 138-139
S-Series........................................................................................................................................................ 140-141
G-Series........................................................................................................................................................ 142-143

Chemical formula Starting devices


R404A: CHF2CF3 / CH3CF3 / CH2FCF3 LST: Low Starting Torque
R507: CHF2CF3 / CH3CF3 LST is used with capillary tube control and pressure
equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel The PTC starting device requires 5 minutes cooling before
Typelabel stripe colour: Lilac each start.
Typelabel colour: Yellow To fulfil the requirements of EN 60355-2-34 the protection
screen 103N0476 must be applied to the PTC starting device.
Applications HST: High Starting Torque
LBP: Low Back Pressure HST consisting of relay and starting capacitor is used for
HBP: High Back Pressure expansion valve control or for capillary tube control without
MBP: Medium Back Pressure pressure equalizing.
ePTC: Electronically controlled PTC
Motor types • Compressor restart possible after a few seconds
RSIR: Resistant Start Induction Run • Operational wattage loss reduced by 2 watt
RSCR: Resistant Start Capacitor Run • PTC protection screen not needed (surface temp. < 82 °C)
CSIR: Capacitor Start Induction Run • Temperature resistant up to min. +60 °C
CSR: Capacitor Start Run • Additonal information, code numbers: refer to page 18
Test conditons
Compressor cooling Electrical equipment being used is listed in our data sheets
S = Static cooling normally sufficient
O = Oil cooling 1 Watt = 0.86 kcal/h
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 3.41 Btu/h
temp. equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary

136
137
R404A/R507 • 220-240 V • 60 Hz • N-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NF7MLX 105F3721 MBP 618 940 1137 666 1.34 1041 1.51 663 1031 1259
NL6.1MLX 105F3611 MBP 507 771 932 546 1.41 854 1.65 544 846 1032

R404A/R507 • 220-240 V • 60 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NF7MLX 105F3721 117U4139 117U5018 117U0349 117U1021
NL6.1MLX 105F3611 117U6022 117U5015 103N1010 103N2011

138

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
427 1.16 842 1.61 1441 2.12 1/2 7.27 187-254 V, 60 Hz * F2 203 197 9.7 6.5 6.5 X 10 | 11
350 1.24 690 1.67 1182 2.29 1/3 6.13 187-254 V, 60 Hz * F2 203 197 8.2 6.5 6.5 10 | 11

NF NL

139

R404A/R507
R404A/R507 • 220-240 V • 60 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10CLX 104L2533 LBP 224 738 244 0.72 786 1.20 156 817
SC12CLX 104L2695 LBP 282 972 303 0.74 1041 1.26 226 1098
SC15CLX 104L2854 LBP 351 1158 391 0.85 1229 1.35 235 1215
SC12CLX.2 104L2697 LBP 343 1011 351 0.85 1083 1.32 317 1087
SC12CLX.2 104L2699 LBP 343 1011 351 0.84 1083 1.46 317 1087
SC15CLX.2 104L2897 LBP 437 1239 444 0.91 1323 1.48 414 1339
SC18CLX.2 104L2195 LBP 542 1410 547 0.91 1482 1.42 521 1556
SC10MLX 104L2506 MBP 816 1246 1510 881 1.37 1371 1.52 843 1334 1637
SC12MLX 104L2606 MBP 970 1465 1770 1040 1.35 1605 1.49 1011 1576 1925
SC18MLX 104L2138 MBP 1412 2106 2538 1502 1.26 2337 1.47 1523 2331 2843
SC15MLX.2 104L2803 MBP 1145 1737 2107 1230 1.36 1934 1.62 1235 1898 2323
SC12/12CLX 104L4034 LBP 561 1935 602 0.73 2072 1.25 451 2185

R404A/R507 • 220-240 V • 60 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10CLX 104L2533 117U6005 117U5017 103N1004 103N2008
SC12CLX 104L2695 117U6019 117U5017 103N1004 103N2008
SC15CLX 104L2854 117U5373 117-7039 103N1004 103N2008
SC12CLX.2 104L2697 117U6019 117U5017 103N1004 103N2008
SC12CLX.2 104L2699 117-7027 103N1004 103N2008
SC15CLX.2 104L2897 117U5373 117-7039 103N1004 103N2008
SC18CLX.2 104L2195 117U5373 117-7066 103N1004 103N2008
SC10MLX 104L2506 117U6011 117U5017 103N1004 103N2008
SC12MLX 104L2606 117U6011 117U5017 103N1004 103N2008
SC18MLX 104L2138 117-7066 103N1004 103N2008
SC15MLX.2 104L2803 117-7058 103N1004 103N2008
SC12/12CLX 104L4034 117U6019 117U5017 103N1004 103N2009

140

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
518 1.16 1/2 10.29 198-254 V, 60 Hz * F2 209 203 8.2 6.2 6.2 X 4 | 10
699 1.23 3/4 12.87 198-254 V, 60 Hz F2 219 213 8.2 6.2 6.2 X 4|6
775 1.23 10 3/4 15.28 198-254 V, 60 Hz F2 219 213 10.2 6.2 6.2 4|6
708 1.20 3/4 12.87 198-254 V, 60 Hz * F2 219 213 8.2 6.2 6.2 X 4|6
708 1.27 10 3/4 12.87 187-254 V, 60 Hz F2 219 213 9.7 6.5 6.5 X 4|6
883 1.33 10 3/4 15.28 187-254 V, 60 Hz F2 219 213 9.7 6.5 6.5 X 4|6
1115 1.40 10 1 17.69 187-254 V, 60 Hz F2 219 213 9.7 6.5 6.5 X 4|6
531 1.15 1086 1.58 1884 2.09 3/4 10.29 187-254 V, 60 Hz * F2 209 203 8.2 6.5 6.5 10 | 11
651 1.18 1285 1.57 2206 2.05 3/4 12.87 187-254 V, 60 Hz * F2 219 213 8.2 6.5 6.5 10 | 11
1034 1.18 1904 1.52 3259 2.07 10 1 17.69 187-254 V, 60 Hz F2 219 213 9.7 6.5 6.5 10 | 11
842 1.20 1549 1.61 2677 2.24 15 3/4 15.28 187-254 V, 60 Hz F2 219 213 10.2 6.5 6.5 10 | 11
1391 1.23 1 1/4 25.74 198-254 V, 60 Hz F2 259 254 12.0 6.2 6.2 4

SC SC-Twin

141

R404A/R507
R404A/R507 • 220-240 V • 60 Hz • G-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
GS21CLX 107B0506 LBP 655 1937 669 1.05 2084 1.65 630 2080
GS26CLX 107B0505 LBP 755 2001 773 0.89 2135 1.27 720 2117
GS21MLX 107B0509 MBP 1939 2950 3578 2088 1.68 3227 1.95 2046 3138 3825

R404A/R507 • 220-240 V • 60 Hz • G-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
GS21CLX 107B0506 117-7056 107B9101
GS26CLX 107B0505 117-7073 107B9101
GS21MLX 107B0509 117-7073 107B9106

142

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
1360 1.53 10 1 1/4 21.20 187-254 V, 60 Hz F2 259 247 12.9 6.5 8.2 4
1427 1.22 20 1 1/4 26.30 187-254 V, 60 Hz F2 279 267 12.9 6.5 8.2 4
2564 1.92 4391 2.65 20 1 1/4 21.20 187-254 V, 60 Hz F2 279 267 12.9 6.5 9.7 4 | 10

GS

143

R404A/R507
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R134a
115 V | 60 Hz

P-Series........................................................................................................................................................ 146-147
T-Series........................................................................................................................................................ 148-149
N-Series........................................................................................................................................................ 150-151
F-Series........................................................................................................................................................ 152-153
S-Series........................................................................................................................................................ 154-155

Chemical formula Starting devices


CH2FCF3 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Blue The PTC starting device requires 5 minutes cooling before
Typelabel colour: Green each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

144
145
R134a • 115 V • 50 - 60 Hz • P-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
PL30F 101G9100 L/M/HBP 44 78 99 154 189 21 0.42 59 0.95 125 1.58 55 97 124 193 236
PL50F 101G9202 L/MBP 69 111 138 37 0.59 88 1.05 85 138 171

R134a • 115 V • 50 - 60 Hz • P-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
PL30F 101G9100 103N0026 103N0023 117U6000 117U5015 103N1010 103N0492
PL50F 101G9202 103N0026 103N0023 117U6000 117U5015 103N1010 103N0492

146

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
30 0.60 80 1.23 156 1.94 1/10 1.41 90-127 V, 60 Hz * S 134 132 6.5 6.5 5.0 1|5
52 0.79 117 1.33 1/10 2.00 103-127 V, 60 Hz S 134 132 6.5 6.5 5.0 1|5

PL

147

R134a
R134a • 115 V • 60 Hz • T-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54,4°C, Tliq=32,2°C, Tsuc=32,2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TF3.5F 102G3304 LBP 30 119 64 0.72 155 1.20 38 147
TFS4F 102G3431 LBP 35 142 75 0.82 186 1.34 44 176
TFS4.5FT 102G3432 L/MBP 56 180 290 358 102 0.84 231 1.27 435 1.69 70 223 360 444
TFS4.5FT 102G3433 LBP 56 180 102 0.84 231 1.27 70 223
TL2.5F 102G3206 LBP 80 134 43 0.70 105 1.11 99 167
TL3F 102G3300 LBP 97 163 54 0.75 127 1.11 121 203
TL4F 102G3402 LBP 42 120 66 0.77 159 1.21 52 149
TL2.5G 102G3255 L/M/HBP 79 144 186 289 350 39 0.57 108 1.14 234 1.85 99 179 231 360 436
TL4G 102G3460 L/M/HBP 123 211 268 408 493 64 0.71 163 1.20 333 1.76 153 263 333 508 615
TLS4.5F 102G3420 LBP 56 180 290 102 0.83 231 1.26 70 223 360
TT2.5F 102G3248 LBP 80 134 43 0.70 105 1.11 99 167
TTE4F 102G3444 LBP 36 152 84 0.94 195 1.46 45 189
TTE4.6FK 102G3448 LBP 50 184 106 1.06 235 1.57 62 229
TTY5F 102G3546 LBP 62 224 126 1.05 289 1.59 77 278

R134a • 115 V • 60 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TF3.5F 102G3304 117U0349 117U1021
TFS4F 102G3431 117U0349 117U1021
TFS4.5FT 102G3432 117U4126 117U5022 117U0349 117U1021
TFS4.5FT 102G3433 117U0349 117U1021
TL2.5F 102G3206 103N0026 103N0023 103N1010 103N2011
TL3F 102G3300 103N0026 103N0023 103N1010 103N2011
TL4F 102G3402 103N0026 103N0023 103N1010 103N2011
TL2.5G 102G3255 103N0026 103N0023 103N1010 103N2011
TL4G 102G3460 103N0026 103N0023 117U6003 117U5023 103N1010 103N2011
TLS4.5F 102G3420 103N0026 103N0023 117U6003 117U5023 103N1010 103N2011
TT2.5F 102G3248 117U6102 117U3301 117U1026
TTE4F 102G3444 117U6102 117U3304 117-7118 117U1026
TTE4.6FK 102G3448 117U6106 117U3302 117-7118 117U1026
TTY5F 102G3546 117U6102 117U3302 117-7118 117U1026

148

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
90 0.96 1/10 3.59 95-135 V, 60 Hz S 173 169 6.5 6.5 5.0 1|5
105 1.08 1/10 3.86 95-135 V, 60 Hz S 173 169 6.5 6.5 5.0 1|5
140 1.10 304 1.56 531 2.00 1/6 4.63 95-135 V, 60 Hz S 173 169 6.5 6.5 4.9 X 1|2
140 1.10 1/8 4.63 95-135 V, 60 Hz S 173 169 6.5 6.5 5.0 X 1|2
60 0.92 140 1.37 1/10 2.61 103-127 V, 60 Hz S 163 159 6.5 6.5 5.0 1|7
74 0.97 170 1.38 1/10 3.13 103-127 V, 60 Hz S 163 159 6.5 6.5 5.0 1|5
91 1.00 214 1.52 1/10 3.86 103-127 V, 60 Hz S 163 159 6.5 6.5 5.0 X 1|5
56 0.78 148 1.48 291 2.26 1/10 2.61 103-127 V, 60 Hz S 163 159 6.5 6.5 5.0 X 3
90 0.94 219 1.51 413 2.13 1/8 3.86 90-135 V, 60 Hz * S 173 169 6.5 6.5 5.0 X 3
140 1.09 304 1.54 1/8 4.63 103-127 V, 60 Hz S 163 159 6.5 6.5 5.0 1|2|5
60 0.92 140 1.37 1/10 2.61 103-127 V, 60 Hz S 158 152 6.5 6.5 4.9 1
117 1.24 15 1/10 3.86 103-127 V, 60 Hz S 173 169 6.5 6.5 5.0 1
145 1.38 15 1/8 4.63 103-127 V, 60 Hz S 173 169 6.5 6.5 5.0 1|2
174 1.38 15 1/6 5.54 103-127 V, 60 Hz S 173 169 6.5 6.5 4.9 1|2

TL TF/TT TFS / TTE / TTY

Note:
On TF and TT
compressors
suction and
process
connectors are
interchangeable.

149

R134a
R134a • 115 V • 60 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NF6FK 105G5628 L/MBP 63 249 397 490 143 0.88 317 1.30 599 1.91 79 309 493 610
NF7FK 105G5728 L/MBP 91 302 473 583 180 0.93 380 1.33 711 1.90 112 374 587 724
NF5.5FX 105G5623 L/MBP 66 260 414 511 148 0.93 330 1.38 624 2.02 83 322 514 635
NF7FX 105G5723 L/MBP 93 311 488 601 186 0.90 392 1.34 733 1.95 116 385 605 746
NF7FX 105G5733 L/MBP 93 311 488 601 186 0.90 392 1.34 733 1.95 116 385 605 746
NF9FX 105G5920 L/MBP 344 548 677 202 0.86 437 1.34 826 1.90 426 679 840
NF10FX 105G5941 L/MBP 386 610 752 227 0.91 488 1.34 919 1.86 476 756 934
NF11FX 105G5945 MBP 114 410 653 808 237 0.84 521 1.27 988 1.77 140 506 809 1003
NF6.1FX.2 105G5631 L/MBP 69 274 442 547 153 0.90 352 1.47 666 2.11 86 341 549 679
NF7.3FX.2 105G5722 L/MBP 91 334 532 656 190 0.88 426 1.40 796 2.00 114 414 661 814
NF8.4FX.2 105G5918 L/MBP 381 603 741 221 0.94 484 1.43 899 2.00 473 749 920
NF11FX.2 105G5916 MBP 485 772 950 618 1.36 1154 1.91 603 959 1180
NLV6.1F 2000 105G5660 L/MBP 43 158 257 319 89 1.16 204 1.78 392 2.61 53 196 319 397
NLV6.1F 3000 105G5660 L/MBP 70 236 378 468 137 1.14 301 1.74 572 2.48 87 292 469 580
NLV6.1F 3500 105G5660 L/MBP 88 285 453 560 167 1.12 362 1.66 683 2.33 109 353 562 694
NLV6.1F 4000 105G5660 L/MBP 93 314 502 622 182 1.07 400 1.61 761 2.30 115 389 623 772
NLV8.4F 2000 105G5960 L/MBP 68 219 348 430 129 1.18 278 1.69 525 2.32 84 271 432 533
NLV8.4F 3000 105G5960 L/MBP 104 335 532 656 197 1.13 425 1.64 801 2.27 129 414 659 814
NLV8.4F 3500 105G5960 L/MBP 119 382 607 749 225 1.11 485 1.60 914 2.21 148 473 752 929
NLV8.4F 4000 105G5960 L/MBP 133 427 678 838 251 1.10 542 1.59 1022 2.20 165 529 841 1039
NTY5.5FK 105G5620 LBP 90 256 151 1.14 329 1.59 111 318
NTY9FK 105G5921 LBP 129 369 221 1.18 469 1.61 159 458

R134a • 115 V • 60 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NF6FK 105G5628 117U4132 117U5022 117U0349 117U1021
NF7FK 105G5728 117U4132 117U5022 117U0349 117U1021
NF5.5FX 105G5623 117U4127 117U5025 117U0349 117U1021
NF7FX 105G5723 117U4061 117U5025 117U0349 117U1021
NF7FX 105G5733 117U4061 117U5025 117U0349 117U1021
NF9FX 105G5920 117U4129 117U5025 117U0349 117U1021
NF10FX 105G5941 117U4129 117U5022 117U0349 117U1021
NF11FX 105G5945 117U4123 117U5028 117U0349 117U1021
NF6.1FX.2 105G5631 117U4127 117U5025 117U0349 117U1021
NF7.3FX.2 105G5722 117U4061 117U5025 117U0349 117U1021
NF8.4FX.2 105G5918 117U4129 117U5025 117U0349 117U1021
NF11FX.2 105G5916 117U4151 117U5028 117U0349 117U1021
NLV6.1F 105G5660 Electronic unit
NLV8.4F 105G5960 105N4212
NTY5.5FK 105G5620 117U6102 117U3306 117-7118 117U1026
NTY9FK 105G5921 117U6102 117U3310 117-7118 117U1026

150

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
196 1.14 416 1.62 739 2.32 1/5 6.13 95-135 V, 60 Hz F2 203 197 8.2 6.5 6.5 X 2
245 1.20 496 1.66 876 2.30 1/4 7.27 95-135 V, 60 Hz F2 203 197 8.2 6.5 6.5 2
205 1.21 433 1.72 770 2.46 1/4 6.13 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 X 3
253 1.18 512 1.67 903 2.36 1/4 7.27 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 X 3
253 1.18 512 1.67 903 2.36 1/4 7.27 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 6.5 3
275 1.12 573 1.67 1017 2.28 1/3 8.35 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 X 3
308 1.18 638 1.65 1132 2.24 1/3 10.09 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 X 3
323 1.09 682 1.56 1219 2.14 1/2 11.15 95-135 V, 60 Hz F2 203 197 8.2 6.5 6.5 X 3
212 1.19 463 1.84 818 2.53 1/4 6.13 95-135 V, 60 Hz F1 197 191 8.2 6.5 6.5 3
263 1.16 558 1.75 978 2.41 1/3 7.27 95-135 V, 60 Hz F1 197 191 8.2 6.5 6.5 3
303 1.22 633 1.77 1102 2.39 1/3 8.35 95-135 V, 60 Hz F1 197 191 8.2 6.5 6.5 3
810 1.70 1416 2.29 1/2 11.25 95-135 V, 60 Hz F2 203 197 9.7 6.5 6.5 X 3
123 1.52 268 2.22 483 3.18 1/7 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
187 1.49 395 2.16 704 3.00 1/7 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
228 1.45 474 2.06 840 2.81 1/7 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
249 1.39 525 2.00 937 2.78 1/7 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
176 1.52 364 2.08 645 2.78 1/5 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
268 1.47 556 2.03 985 2.73 1/5 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
307 1.43 635 1.98 1124 2.66 1/5 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
343 1.42 710 1.97 1257 2.64 1/5 8.35 80-140 V, 60 Hz * F2 203 197 8.2 6.5 6.5 3
205 1.48 15 1/5 6.13 103-127 V, 60 Hz S 203 197 8.2 6.5 6.5 2
299 1.53 15 1/4 8.35 103-127 V, 60 Hz S 203 197 8.2 6.5 6.5 2

NF/NTY NLV

151

R134a
R134a • 115 V • 60 Hz • F-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
FF6GK 103G5680 L/M/HBP 187 345 445 685 83 0.68 259 1.28 558 1.97 234 430 553 852
FF7.5GK 103G5780 L/M/HBP 221 391 498 753 106 0.77 299 1.30 618 1.89 274 485 617 935
FF8.5GX 103G5880 L/M/HBP 268 454 569 841 139 0.70 354 1.18 698 1.73 332 563 706 1045
FF10GX 103G5980 L/M/HBP 291 498 625 931 149 0.68 386 1.16 770 1.71 362 619 778 1159

R134a • 115 V • 60 Hz • F-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
FF6GK 103G5680 117U0349 117U1021
FF7.5GK 103G5780 117U0349 117U1021
FF8.5GX 103G5880 117U4060 117U5041 117U0349 117U1021
FF10GX 103G5980 117U4061 117U5040 117U0349 117U1021

152

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
122 0.93 356 1.63 693 2.38 1/5 6.23 103-127 V, 60 Hz F1 196 191 8.2 6.5 6.5 3
152 1.02 404 1.63 763 2.27 1/4 6.93 103-127 V, 60 Hz F1 196 191 8.2 6.5 6.5 3
195 0.93 472 1.49 857 2.08 1/4 7.95 103-127 V, 60 Hz F2 196 191 8.2 6.5 6.5 3
210 0.91 518 1.46 949 2.05 1/3 9.05 103-127 V, 60 Hz F2 196 191 8.2 6.5 6.5 3

FF

153

R134a
R134a • 115 V • 60 Hz • S-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC15FTX 104G7505 LBP 158 571 898 332 0.87 722 1.23 199 707 1114
SC12G 104G7250 L/M/HBP 43 422 729 924 1414 202 0.73 563 1.27 1151 1.90 60 528 909 1152 1765
SC12G 104G7260 L/M/HBP 43 422 729 924 1414 202 0.73 563 1.27 1151 1.90 60 528 909 1152 1765
SC15G 104G7550 L/M/HBP 502 876 1099 1639 190 0.67 679 1.24 1352 1.78 625 1087 1364 2039
SC18G 104G7800 L/M/HBP 592 995 1238 1829 2187 264 0.71 782 1.23 1514 1.72 740 1240 1542 2282 2734
SC15MFX 104G7520 MBP 532 916 1142 1666 713 1.37 1392 1.96 664 1140 1423 2079

R134a • 115 V • 60 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC15FTX 104G7505 117U6020 117U5023 103N1004 103N2008
SC12G 104G7250 117U6020 117U5023 103N1004 103N2008
SC12G 104G7260 117U6020 117U5023 103N1004 103N2008
SC15G 104G7550 117U6020 117U5023 103N1004 103N2008
SC18G 104G7800 117-7441 117U5042 117-7053 117U1021
SC15MFX 104G7520 117U6020 117U5023 103N1004 103N2008

154

R134a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
456 1.13 942 1.51 1/2 15.28 90-135 V, 60 Hz * F2 209 203 8.2 6.5 6.5 X 4
296 0.99 760 1.61 1432 2.31 1/2 12.87 103-127 V, 60 Hz F1 209 203 8.2 6.5 6.5 X 3
296 0.99 760 1.61 1432 2.31 1/2 12.87 103-127 V, 60 Hz F1 209 203 8.2 6.5 6.5 6.5 3
304 0.95 910 1.55 1666 2.15 1/2 15.28 103-127 V, 60 Hz F1 209 203 8.2 6.5 6.5 X 3
400 0.99 1042 1.53 1868 2.08 3/4 17.69 95-135 V, 60 Hz F2 219 213 9.7 6.5 6.5 X 3
357 1.04 956 1.72 1713 2.37 1/2 15.28 95-135 V, 60 Hz F2 209 203 9.7 6.5 6.5 4

SC SC (ext. protector)

155

R134a
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R600a
115 V | 60 Hz

N-Series........................................................................................................................................................ 158-159

Chemical formula Starting devices


C4H10 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Red The PTC starting device requires 5 minutes cooling before
Typelabel colour: Green each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

156
157
R600a • 115 V • 60 Hz • N-Series
CECOMAF CECOMAF ASHRAE
Capacity [W] Capacity [W]

Application
Tc=55°C, Tliq=55°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54,4°C, Tliq=32,2°C, Tsuc=32,2°C
Code Evaporating temperature [°C] -25°C / 55°C -10°C / 55°C 5°C / 55°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NLE11KTK 105H5942 L/MBP 87 255 395 470 145 0.95 322 1.42 544 1.83 106 310 482 574
NLE13KTK 105H5949 L/MBP 100 284 441 535 170 0.95 357 1.37 638 1.78 122 346 538 653

R600a • 115 V • 60 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NLE11KTK 105H5942 103N0026 103N0023 103N0027 103N0024 117-7118 117-7120 103N1010 103N2010
NLE13KTK 105H5949 103N0026 103N0023 103N0027 103N0024 117-7118 117-7120 103N1010 103N2010

158

R600a
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
196 1.23 414 1.72 * 1/5 11.15 95-135 V, 60 Hz F1 197 191 8.2 6.5 6.5 2|4
227 1.21 460 1.66 * 1/5 13.25 95-135 V, 60 Hz F1 197 191 8.2 6.5 6.5 2|4

NLE

159

R600a
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R404A/R507
115 V | 60 Hz

T-Series........................................................................................................................................................ 162-163
N-Series........................................................................................................................................................ 164-165
S-Series........................................................................................................................................................ 166-167

Chemical formula Starting devices


R404A: CHF2CF3 / CH3CF3 / CH2FCF3 LST: Low Starting Torque
R507: CHF2CF3 / CH3CF3 LST is used with capillary tube control and pressure
equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel The PTC starting device requires 5 minutes cooling before
Typelabel stripe colour: Lilac each start.
Typelabel colour: Green To fulfil the requirements of EN 60355-2-34 the protection
screen 103N0476 must be applied to the PTC starting device.
Applications HST: High Starting Torque
LBP: Low Back Pressure HST consisting of relay and starting capacitor is used for
HBP: High Back Pressure expansion valve control or for capillary tube control without
MBP: Medium Back Pressure pressure equalizing.
ePTC: Electronically controlled PTC
Motor types • Compressor restart possible after a few seconds
RSIR: Resistant Start Induction Run • Operational wattage loss reduced by 2 watt
RSCR: Resistant Start Capacitor Run • PTC protection screen not needed (surface temp. < 82 °C)
CSIR: Capacitor Start Induction Run • Temperature resistant up to min. +60 °C
CSR: Capacitor Start Run • Additonal information, code numbers: refer to page 18
Test conditons
Compressor cooling Electrical equipment being used is listed in our data sheets
S = Static cooling normally sufficient
O = Oil cooling 1 Watt = 0.86 kcal/h
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 3.41 Btu/h
temp. equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary

160
161
R404A/R507 • 115 V • 60 Hz • T-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TF4CLX 102U2102 L/MBP 101 285 427 513 101 0.71 305 1.21 470 1.23 100 311 475 576
TFS4.5CLX 102U2103 LBP 137 366 137 0.83 388 1.18 140 402

R404A/R507 • 115 V • 60 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TF4CLX 102U2102 117U4148 117U5025 117U0349 117U1021
TFS4.5CLX 102U2103 117U4148 117U5025 117U0349 117U1021

162

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
207 1.13 389 1.44 654 1.72 1/5 3.86 103-135 V, 60 Hz F2 173 169 6.5 6.5 5.0 4 | 5 | 10 | 11
273 1.20 496 1.40 1/4 4.63 103-135 V, 60 Hz F2 173 169 6.5 6.5 5.0 4|5

TL

163

R404A/R507
R404A/R507 • 115 V • 60 Hz • N-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NF5.5CLX 105F1621 L/MBP 190 495 728 869 189 0.84 524 1.30 799 1.43 192 539 814 984
NF7CLX 105F1721 L/MBP 230 623 923 1105 230 0.83 662 1.33 1017 1.47 228 675 1029 1248

R404A/R507 • 115 V • 60 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NF5.5CLX 105F1621 117U4061 117U5025 117U0349 117U1021
NF7CLX 105F1721 117U4129 117U5022 117U0349 117U1021

164

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
367 1.23 667 1.58 1113 2.02 1/3 6.13 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 X 4 | 10 | 11
453 1.23 841 1.61 1417 2.08 1/2 7.27 95-135 V, 60 Hz F2 197 191 8.2 6.5 6.5 X 4 | 10 | 11

NF

165

R404A/R507
R404A/R507 • 115 V • 60 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10CL 104L1503 L/MBP 172 729 1148 1401 198 0.66 802 1.29 1262 1.50 130 701 1157 1442
SC12CL 104L1603 LBP 282 972 303 0.66 1041 1.13 226 1098
SC12CLX.2 104L1696 LBP 334 997 345 0.74 1062 1.19 304 1106
SC15CLX.2 104L1853 LBP 437 1239 444 0.83 1323 1.35 414 1339
SC18CLX.2 104L2198 LBP 523 1360 528 0.86 1430 1.34 503 1502
SC12MLX 104L1606 MBP 978 1484 1799 1051 1.30 1661 1.52 1042 1631 2003
SC15MLX 104L1805 MBP 1129 1714 2078 1213 1.22 1918 1.42 1203 1883 2313
SC18MLX 104L2105 MBP 1412 2106 2538 1502 1.26 2337 1.47 1523 2331 2843
SC15MLX.2 104L1807 MBP 1147 1715 2069 1222 1.30 1905 1.49 1236 1897 2315

R404A/R507 • 115 V • 60 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10CL 104L1503 117U6020 117U5023 103N1004 103N2008
SC12CL 104L1603 117U6020 117U5023 103N1004 103N2008
SC12CLX.2 104L1696 117U6020 117U5023 103N1004 103N2008
SC15CLX.2 104L1853 117-7114 117-7441 117U5043 117-7045 117U1021
SC18CLX.2 104L2198 117-7114 117-7441 117U5043 117-7045 117U1021
SC12MLX 104L1606 117-7441 117U5042 117-7053 117U1021
SC15MLX 104L1805 117-7114 117-7441 117U5043 117-7045 117U1021
SC18MLX 104L2105 117-7114 117-7441 117U5043 117-7045 117U1021
SC15MLX.2 104L1807 117-7114 117-7441 117U5043 117-7045 117U1021

166

R404A/R507
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
418 0.99 936 1.47 1690 2.05 1/2 10.29 103-127 V, 60 Hz F2 209 203 8.2 6.5 6.5 X 4 | 10 | 11
699 1.11 3/4 12.87 103-127 V, 60 Hz F2 209 203 8.2 6.5 6.5 X 4
726 1.14 1381 1.48 3/4 12.87 103-127 V, 60 Hz F2 209 203 8.2 6.5 6.5 X 4
883 1.21 1683 1.62 * 3/4 15.28 103-127 V, 60 Hz F2 219 213 9.7 6.5 6.5 X 4
1076 1.32 1783 1.61 1 17.69 103-127 V, 60 Hz F2 219 213 9.7 6.5 6.5 X 4
686 1.18 1328 1.56 2315 2.12 3/4 12.87 95-135 V, 60 Hz F2 219 213 8.2 6.5 6.5 10 | 11
792 1.10 1533 1.45 2673 1.98 * 3/4 15.28 95-135 V, 60 Hz F2 219 213 9.7 6.5 6.5 10 | 11
1034 1.18 1904 1.52 3259 2.07 23.5 1 17.69 103-127 V, 60 Hz F2 219 213 9.7 6.5 6.5 10 | 11
836 1.23 1548 1.55 2656 2.09 23.5 3/4 15.28 103-127 V, 60 Hz F2 219 213 9.7 6.5 6.5 10 | 11

SC SC (ext. protector)

167

R404A/R507
With more than 50 years of compressor technologies
experience in compressor to achieve standard setting
technology and highly performance for leading
committed employees, our products and businesses
focus is to develop and around the world.
apply the advanced

R290
115 V | 60 Hz

T-Series........................................................................................................................................................ 170-171
D-Series........................................................................................................................................................ 172-173
N-Series........................................................................................................................................................ 174-175
S-Series........................................................................................................................................................ 176-177

Chemical formula Starting devices


C3H8 LST: Low Starting Torque
LST is used with capillary tube control and pressure
Typelabel equalizing. (Pressure equalizing may exceed 10 minutes).
Typelabel stripe colour: Red The PTC starting device requires 5 minutes cooling before
Typelabel colour: Green each start.
To fulfil the requirements of EN 60355-2-34 the protection
Applications screen 103N0476 must be applied to the PTC starting device.
LBP: Low Back Pressure HST: High Starting Torque
HBP: High Back Pressure HST consisting of relay and starting capacitor is used for
MBP: Medium Back Pressure expansion valve control or for capillary tube control without
pressure equalizing.
Motor types ePTC: Electronically controlled PTC
RSIR: Resistant Start Induction Run • Compressor restart possible after a few seconds
RSCR: Resistant Start Capacitor Run • Operational wattage loss reduced by 2 watt
CSIR: Capacitor Start Induction Run • PTC protection screen not needed (surface temp. < 82 °C)
CSR: Capacitor Start Run • Temperature resistant up to min. +60 °C
• Additonal information, code numbers: refer to page 18
Compressor cooling Test conditons
S = Static cooling normally sufficient Electrical equipment being used is listed in our data sheets
O = Oil cooling
F1 = Fan cooling 1.5 m/s (compressor compartment 1 Watt = 0.86 kcal/h
temp. equal to ambient temperature) 1 Watt = 3.41 Btu/h
F2 = Fan cooling 3.0 m/s necessary

168
169
R290 • 115 V • 60 Hz • T-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
TL4.0CNX.2 102H3490 L/MBP 112 292 438 530 111 0.81 319 1.57 517 2.07 107 310 467 566
TL4.8CNX.2 102H3590 L/MBP 141 356 521 621 141 0.90 384 1.57 601 1.96 137 380 560 668

R290 • 115 V • 60 Hz • T-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
TL4.0CNX.2 102H3490 117U7005 117U5023 103N1010 103N2011
TL4.8CNX.2 102H3590 117U7005 117U5023 103N1010 103N2011

170

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
212 1.27 399 1.85 671 2.69 1/5 4.01 95-135 V, 60 Hz F2 173 169 6.5 6.5 5.0 3|4|5|7|10|11
263 1.34 479 1.86 772 2.52 1/4 4.78 95-135 V, 60 Hz F2 173 169 6.5 6.5 5.0 3|4|5|7|10|11

TL

171

R290
R290 • 115 V • 60 Hz • D-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
DLE4CN 102H3482 L/MBP 126 315 464 555 123 1.03 341 1.81 536 2.32 128 331 494 595
DLE4.8CN 102H3582 L/MBP 160 384 563 672 157 1.01 414 1.75 646 2.25 154 408 600 717

R290 • 115 V • 60 Hz • D-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device optional or compulsory Starting Starting Starting Starting
Code ePTC
Compressor with RC connector (refer to data sheet) relay capacitor device * kit *
number Cord
Spades Spades Spades Spades Spades Spades Cover
relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
DLE4CN 102H3482 103N0058 117-7118 117U7022 117U5023 103N1010 103N0492
DLE4.8CN 102H3582 103N0058 117-7118 117U7011 117U5023 103N1010 103N0492

172

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
230 1.50 422 2.10 699 3.01 * 1/5 4.01 95-135 V, 60 Hz 175 169 8.2 6.5 6.5 3|4|6|10|11
286 1.47 514 2.06 835 2.97 * 1/4 4.78 95-135 V, 60 Hz 175 169 8.2 6.5 6.5 3|4|6|10|11

DLE

173

R290
R290 • 115 V • 60 Hz • N-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C /40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
NL7.3CNX.2 105H6790 L/MBP 226 577 856 1024 214 0.90 627 1.71 990 2.16 244 612 917 1103
NL8.4CNX.2 105H6090 L/MBP 263 664 976 1167 254 1.00 717 1.71 1127 2.10 267 699 1038 1249

R290 • 115 V • 60 Hz • N-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
NL7.3CNX.2 105H6790 117U7013 117U5035 103N1010 103N2011
NL8.4CNX.2 105H6090 117U7013 117U5035 103N1010 103N2011

174

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
422 1.44 783 2.02 1288 2.81 1/2 7.27 95-135 V, 60 Hz F2 203 197 8.2 6.5 6.5 3|4|5|7|10|11
487 1.47 887 1.98 1467 2.72 1/2 8.35 95-135 V, 60 Hz F2 203 197 8.2 6.5 6.5 3|4|5|7|10|11

NL

175

R290
R290 • 115 V • 60 Hz • S-Series
EN 12900 EN 12900 ASHRAE
Capacity [W] Capacity [W]

Application
Tc=45°C, Tliq=45°C, Tsuc=32°C LBP rating point MBP rating point HBP rating point Tc=54.4°C, Tliq=32.2°C, Tsuc=32.2°C
Code Evaporating temperature [°C] -35°C / 40°C -10°C / 45°C 5°C / 50°C Evaporating temperature [°C]
Compressor
number
Cooling Cooling Cooling
COP COP COP
-35 -15 -5 0 10 15 capacity capacity capacity -35 -15 -5 0 10 15
[W] [W/W] [W] [W/W] [W] [W/W]
SC10CNX.2 104H7070 L/MBP 209 712 1093 1323 224 0.76 789 1.61 1298 2.26 156 728 1163 1428
SC12CNX.2 104H7270 L/MBP 308 881 1315 1577 311 0.86 961 1.65 1542 2.11 282 930 1423 1723

R290 • 115 V • 60 Hz • S-Series • Electrical Equipment


LST (RSIR & RSCR) - refer to data sheet for more info Run capacitor (RC) HST (CSIR & CSR) - * alt. cable lengths avail. LST/HST
PTC starting device PTC starting device Protector optional or compulsory Starting Starting Starting Starting
Code with RC connector (external) (refer to data sheet) relay capacitor device * kit *
Compressor Cord
number Cover
Spades Spades Spades Spades Spades Spades relief
6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
SC10CNX.2 104H7070 117U7020 117U5023 103N1004 103N2008
SC12CNX.2 104H7270 117U7020 117U5023 103N1004 103N2008

176

R290
Refrigerators = 1 | Freezers = 2 | Beverage coolers = 3 | Commercial freezers = 4 | Minibars = 5 | Ice cream cabinets = 6
Water coolers = 7 | Heat pumps = 8 | Wine coolers = 9 | Display cabinets = 10 | Ice makers = 11

(refer to data sheet)


ASHRAE Dimensions

Run capacitor

Displacement
(* optional)

Compressor

Application
alt. connectors
Voltage and

Power
LBP rating point MBP rating point HBP rating point Height Connectors location/I.D.

cooling
-23.3°C / 54.4°C -6.7°C / 54.4°C 7.2°C / 54.4°C frequencies [mm] [mm]

available
(* dual frequency
Cooling Cooling Cooling type with 50/60 Hz) Suction Process Dis- Oil
COP COP COP
capacity capacity capacity charge cooler
[W] [W/W] [W] [W/W] [W] [W/W] μF [HP] [cm³] A B C D E F
449 1.17 985 1.93 1/2 10.29 95-135 V, 60 Hz F2 209 203 9.7 6.5 6.5 3|4|7|10|11
614 1.29 1212 1.93 3/4 12.87 95-135 V, 60 Hz F2 209 203 9.7 6.5 6.5 3|4|7|10|11

SC

177

R290
NOTES

178
NOTES

179
www.secop.com

OUR IDENTITY
At Secop we are committed to our industry and are genuinely passionate about the difference we are able to
make for our customers. We understand their business and objectives and the challenges of today's world of
refrigeration and cooling systems.
We work in a straightforward way, being open, direct and honest because we want to make things clear and
easy.
Our people are committed to increasing value for our customers and constantly strive for better performance,
knowing that our own progression and success is dependent on theirs.

OUR JOURNEY
SO FAR 1970 2013
1956
Introduction of SC
compressors. 1999 2008 Introduction of the XV compressor.

Production facility and


The birth of a stand-
ard setting platform
1990 1992 Start of production with
natural refrigerant
2005 Production facility
in Wuqing, China
Opening a new chapter in
refrigeration history.
headquarters in Flens- in the light commer- Introduction NL Introduction PL R290 (Propane). Introduction GS founded. Secop acquires ACC Fürstenfeld,
burg, Germany founded cial market. compressors. compressors. compressors. Austria.

1958 1972 1977 1993 2002 2010


Start up production Introduction FR Introduction TL and Start of production with Production facility Introduction SLV-CNK.2 and SLV-CLK.2
of PW compressors. compressors. BD compressors. natural refrigerant R600a (Isobutane) in Zlate Moravce, variable speed compressors.
Slovakia founded. Introduction BD1.4F Micro DC compressor.
Production facility in Crnomelj, Introduction of DLX and NLU compressors.
Slovenia founded.

Secop GmbH · Mads-Clausen-Str. 7 · 24939 Flensburg · Germany · Tel: +49 461 4941 0 · www.secop.com
Secop can accept no responsibility for possible errors in catalogues, brochures and other printed material. Secop reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the
respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved