Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
193 views1 page

Agma Iso 1940

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

I�

Agma 9000 C 90 1801940-1

Output It defines class It defines Grade

Parameter Potential Unbalance Permissible unbalance

Class 9 = 52 gm.mm
Permisible
Grade *1000*60*Wt in Kg
Unbalance -

2*3.14*N
gram*mm/ Kg
Value Class 10= 26 gm.mm

Class 11 = 13 gm.mm whereN= R PM

Use Ba s e d o n S p e e d Ba s e d o n Ap p l i c a t i o n

G 6.3 = Centrifugal Pumps


Ref API 610 or 671 G 2.5 = Turbines
G 1.0 =Precision Equipment like
Grindingmachine Drive

Note: 1 For Given class , equivalent grade can be calculated using Permissible
Unbalance formula as per ISO 1940-1
2 I n general, Standard R a t h i c o u p l i n g s fulfill AGMA C l a s s 9
and can be further balanced against customer requirements to Grade 6.3 I 2.5

Prepared by: MG Patil


Date : 22 Feb 2012