Product designation
● _1 / of the accessories that can be ordered sealable end cover
● _2 / of the accessories that can be ordered input reactor / 1AC
Main circuit
Number of poles / for main current circuit 0
Number of NO contacts / for main contacts 0
Number of NC contacts / for main contacts 0
Operating voltage / at AC
● at 50 Hz / rated value 400 ... 600 V
● at 60 Hz / rated value 400 ... 600 V
Operating frequency / rated value 50 ... 60 Hz
Relative symmetrical tolerance / of the operating 10 %
frequency
Operating range relative to the operating voltage / at
AC
● at 50 Hz 340 ... 660 V
● at 60 Hz 340 ... 660 V
Operating current
● at AC-1 / at 400 V / rated value 50 A
● at AC-51 / rated value 50 A
Derating temperature 40 °C
Connections/ Terminals
Type of electrical connection
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
● for auxiliary and control contacts
— solid 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
— finely stranded / with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
— finely stranded / without core end 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
processing
● at AWG conductors / for auxiliary and control 1x (AWG 20 ... 12)
contacts
Tightening torque / for auxiliary and control contacts / 0.5 ... 0.6 N·m
with screw-type terminals
Tightening torque [lbf·in]
● for auxiliary and control contacts / with screw- 4.5 ... 5.3 lbf·in
type terminals
Design of the thread / of the connection screw
● of the auxiliary and control contacts M3
Wire stripping length / of the cable
● for auxiliary and control contacts 7 mm
Ambient conditions
Ambient temperature
● during operation -25 ... +60 °C
● during storage -55 ... +80 °C
Electromagnetic compatibility
Conducted interference
● due to burst / acc. to IEC 61000-4-4 2 kV / 5 kHz behavior criterion 2
● due to conductor-earth surge / acc. to IEC 2 kV behavior criterion 2
61000-4-5
● due to conductor-conductor surge / acc. to IEC 1 kV behavior criterion 2
61000-4-5
● due to high-frequency radiation / acc. to IEC 140 dBuV in the frequency range 0.15 ... 80 MHz, behavior
61000-4-6 criterion 1
Electrostatic discharge / acc. to IEC 61000-4-2 4 kV contact discharging / 8 kV air discharging, behavior criterion
2
Conducted HF-interference emissions / acc. to Class A for industrial environment
CISPR11
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
www.siemens.com/sirius/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RF2950-0KA16
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RF2950-0KA16
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RF2950-0KA16
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RF2950-0KA16&lang=en
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF20_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF21_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF22_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF23_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF24_eng.pdf
45 40
111.5
2 4 V AC/ DC
~ ~ NC AC
0- 10V
A1 A2 IN/ 11 12 L/ N
- +
29.5
A1 A2 IN 0 - 1 0 V 1 1 1 2 L/ N
31.5 38