Aol Eng PDF
Aol Eng PDF
Aol Eng PDF
BIG
“Quick brown fox jumps over the lazy dog” Installation at Università Statale di Milano
Milano Design Week | 2017
Photo: Saverio Lombardi Vallauri
Fico Eataly World, Bologna | 2017
Alphabet of light
Linear-Circular
→ Patent pending for optics
→ Patent pending for the mechanical and electrical connection
LINEAR
ø130
ø130
100
100
100
ø50
ø50
ø50
CIRCULAR
ø237 ø237
100
100
ø50
ø50
ø900 ø1550
ALPHABET OF LIGHT - WALL /CEILING SEMI-RECESSED
LINEAR SEMI-RECESSED
Linear
W Flux CCT Code
Linear 120 29 W 3480 lm 3000K 1425000A
Linear 180 44 W 5226 lm 3000K 1426000A
Linear 240 58 W 6968 lm 3000K 1427000A
ø130
ø130
100
100
100
ø50
ø50
ø50
CIRCULAR SEMI-RECESSED
ø130 ø130
100
100
ø50
ø50
ø900 ø1550
LINEAR
Linear PUSH/DALI PUSH & APP
W Flux CCT Code Code
Linear 120 35 W 3484 lm 3000K 1204000A 1204000APP
Linear 180 50 W 5226 lm 3000K 1205000A 1205000APP
Linear 240 63 W 6968 lm 3000K 1208000A 1208000APP
ø237
ø237
min 500 - max 1500
100
100
100
ø50
ø50
ø50
CIRCULAR
Circular PUSH/DALI PUSH & APP
W Flux CCT Code Code
Circular ø 90 55 W 6040 lm 3000K 1206000A 1206000APP
Circular ø 155 91W 10740 lm 3000K 1207000A 1207000APP
ø237 ø237
min 500 - max 1500
100
100
ø50
ø50
ø900 ø1550
Alphabet of light
System
→ Patent pending for optics
→ Patent pending for the mechanical and electrical connection
Linear 1800 90° curve down Linear 1200 2x 45° curve
90° curve down terminal + 90° curve up intermediate intermediate
powered not powered not powered
Linear 1800 Linear 1800 60° curve Linear 1800 2x 45° curve Linear 1200 3x 60° curve Linear 1800
terminal intermediate intermediate intermediate intermediate intermediate intermediate intermediate
powered not powered not powered not powered not powered not powered not powered not powered
Alphabet of light
System
configuration
Suspension kit Suspension kit Ceiling rose Suspension kit
with power
Suspension kit
Max 10 m for each power unit (10 m in one direction or 5 m in both directions)
Ceiling rose with power supply for each group.
DALI dimming possible for the entire system or for groups of modules powered by the same driver
Suspension modules
→ LINEAR ELEMENTS
1800 mm terminal
1800 mm intermediate
45° terminal left 45° terminal right 45° intermediate 90° Vertical UP
R295 mm
R750 mm
60° terminal left 60° terminal right 60° intermediate 90° Vertical DOWN
R295 mm
R425 mm
ALPHABET OF LIGHT - SYSTEM
VERTICAL ELEMENTS
Not powered
Length W V Flux CCT Code
90° vertical UP 8W 24V 728 lm 3000K 2124010A
3500K 2124C10A
90° vertical DOWN 8W 24V 728 lm 3000K 2125010A
3500K 2125C10A
Accessories Rose
Joint n° Code Code
Linear - linear joint 01 2250010A Rose / power 2267010A
Linear - curve 45° right joint 02 2251010A Rose / power APP 2267010APP
Linear - curve 45° left joint 03 2252010A 2EMOTE / power 2272010A
45° curve - 45° curve joint 04 2255010A 2EMOTE rose / power APP 2272010APP
Linear - curve 60° right joint 05 2253010A
Linear - curve 60° left joint 06 2254010A
60° curve - 60° curve joint 07 2256010A
60° curve - 45° curve S joint 08 2257010A Suspension accessories
45° curve left - 45° curve left S joint 09 2260010A Code
60° curve left - 60° curve left S joint 10 2259010A Suspension kit L=1,50m 2266010A
60°/45° curve left - 45°/60° curve right joint 11 2261010A Suspension kit L=4m 2273010A
60°/45° curve right - 45°/60° curve left joint 12 2262010A Lengthening L=1,25m 2274010A
90° vertical UP - 90° vertical DOWN S joint 13 2263010A Lengthening L=2,50m 2275010A
Lineare - 90° vertical UP joint 14 2264010A
Linear - 90° vertical DOWN joint 15 2265010A
45° curve - 60° curve S joint 16 2258010A
60° curve right - 60° curve right joint 17 2269010A
45° curve right - 45° curve right joint 18 2270010A
Wall/ceiling modules
→ LINEAR ELEMENTS
1800 mm terminal
1800 mm intermediate
45° terminal left 45° terminal right 45° intermediate 90° vertical UP
R295 mm
R750 mm
60° terminal left 60° terminal right 60° intermediate 90° vertical DOWN
R295 mm
R425 mm
ALPHABET OF LIGHT - SYSTEM
VERTICAL ELEMENTS
Not powered
Length W V Flux CCT Code
90° vertical UP 8W 24V 728 lm 3000K 2124010A
3500K 2124C10A
90° vertical DOWN 8W 24V 728 lm 3000K 2125010A
3500K 2125C10A
Accessories
Joint n° Code
Linear - linear joint 01 2250010A
Linear - curve 45° right joint 02 2251010A
Linear - curve 45° left joint 03 2252010A
45° curve - 45° curve joint 04 2255010A
Linear - curve 60° right joint 05 2253010A
Linear - curve 60° left joint 06 2254010A
60° curve - 60° curve joint 07 2256010A
60° curve - 45° curve S joint 08 2257010A
45° curve left - 45° curve left S joint 09 2260010A
60° curve left - 60° curve left S joint 10 2259010A
60°/45° curve left - 45°/60° curve right joint 11 2261010A
60°/45° curve right - 45°/60° curve left joint 12 2262010A
90° vertical UP - 90° vertical DOWN S joint 13 2263010A
Lineare - 90° vertical UP joint 14 2264010A
Linear - 90° vertical DOWN joint 15 2265010A
45° curve - 60° curve S joint 16 2258010A
60° curve right - 60° curve right joint 17 2269010A
45° curve right - 45° curve right joint 18 2270010A
Wall/Ceiling accessories
Code
Rose / power 2268010A
Rose / power APP 2268010APP
Driver for recessed version (240W, 220-240 VAC, IP67, L240 X W67 X H35 , DALI) 2271010A
BLL MODULE for APP management in the recessed version 2271010APP
Joints
X joint
Modules
An entire alphabet composed by 7 elements:
5 joints + 2 constructive modules
with electro mechanical connections
900 300 900
→ M D F S U P P O R T I N S TA L L AT I O N
550
The letters are provided mounted on MDF panels to allow installation
on any kind of wall. Installation requires creating a counter-frame to
1450
accommodate the drivers, supplied separately, and the power cables.
A configuration software is available to calculate the necessary
usable surface, as well as to identify the codes required to implement
1450
the desired project.
550
1. Create the supporting frame and provide for 2. Connect panel b to power source. 3. Fix panel b and connect panel i to power source.
power connections for the individual letters.
4. Fix panel i and connect panel g to power 5. Fix panel g and close using the supplied panels. 6. Complete closing using the supplied panels.
source.
7. Frame ready for finishing. 8. Apply the gauze and plaster flush with the gaps 9. Final painting.
between panels.
→ C A R D B O A R D M O U N T I N G - S U P P O R T I N S TA L L AT I O N
650 50 650
The letters are provided with a packaging that ensures the right
support during the installation process. This type of installation is
suitable for existing drywalls that have accessible back space for the
housing of drivers (code DV1009) supplied separately and cables
950
(power supply 75 W max - 2 letters or more up to max 85% load).
950
1. Drywall with accessible back space. 2. Use the provided template to drill the holes and 3. Install wall pins, identify output points and prepare
paint the drywall. wiring connections.
4. Connection of letter b to first wall output. 5. Attachment of letter b on wall pins. 6. Detail of the wall pins fixing.
7. Detail of the wall pins fixing. 8. Removal of the nylon wrapper. 9. Removal of the cardboard support.
i
10. Connect letter to first wall output. i
11. Fix letter on wall pins. 12. Removal of the nylon wrapper.
13. Attachment of letter g to first wall output. 14. Removal of the nylon wrapper. 15. Finished.
2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
550 1450 550 1450 550 900 550 550 900 550 550 1450 550 900 550 550 1450 550 1450 550 1450 550 1450
900
900
900
900
900
900
900
900
900
900
900
900
900
300
900
900
900
300
1200
1200
550 1450
550 1450 550 1450 550 900 550 1450 550 550 900 550 550 1450 550 1450 550 1450
1450 550
900
900
900
900
600
900
900
900
900
550 1450 1450 550 550 1450 550 1450 550 1450 1200 550 1450 550 1450 550 1450
550 900 550
900
900
900
900
900
900
900
600
900
550 1450 550 1450
550 1450 550 900 550 550 900 550 550 1450 550 1450 550 1450
550 1450
900
900
300
900
900
900
900
1200
1200
550 900 550 550 1450
550 1450 550 1450 550 1450 550 1450 550 1450
550 1450 550 1450
900
900
600
900
600
900
900
900
1200
550 1450 550 1450 550 900 550 550 900 550 1450 550 550 1450 550 1450 550 1450 550 1450
900
900
900
900
900
900
900
900
900
550 1450
550 900 550
900
900
ALPHABET OF LIGHT - LETTERS
Letter W Flux HxL Letters + Support Letter W Flux HxL Letters + Support
A 30 W 2300lm 950 x 650 1201A00A 1211A00A 0 27 W 2100lm 950 x 650 1200000A 1210000A
B 31 W 2450lm 950 x 650 1201B00A 1211B00A 1 23 W 1650lm 950 x 650 1200100A 1210100A
C 20 W 1450lm 950 x 650 1201C00A 1211C00A 2 28 W 2100lm 950 x 650 1200200A 1210200A
D 29 W 2300lm 950 x 650 1201D00A 1211D00A 3 24 W 1700lm 950 x 650 1200300A 1210300A
E 26 W 1900lm 950 x 650 1201E00A 1211E00A 4 23 W 1650lm 950 x 650 1200400A 1210400A
F 19 W 1400lm 950 x 650 1201F00A 1211F00A 5 29 W 2200lm 950 x 650 1200500A 1210500A
G 21 W 1050lm 950 x 650 1201G00A 1211G00A 6 25 W 1850lm 950 x 650 1200600A 1210600A
H 27 W 3200lm 950 x 650 1201H00A 1211H00A 7 19 W 1400lm 950 x 650 1200700A 1210700A
I 11 W 750lm 950 x 50 1201I00A 1211I00A 8 33 W 2600lm 950 x 650 1200800A 1210800A
J 21 W 1550lm 950 x 650 1201J00A 1211J00A 9 25 W 1850lm 950 x 650 1200900A 1210900A
K 26 W 1900lm 950 x 650 1201K00A 1211K00A
L 17 W 2450lm 950 x 650 1201L00A 1211L00A
M 38 W 2900lm 950 x 950 1201M00A 1211M00A
N 25 W 1900lm 950 x 650 1201N00A 1211N00A
O 27 W 2100lm 950 x 650 1201O00A 1211O00A
P 27 W 2300lm 950 x 650 1201P00A 1211P00A
Q 31 W 3000lm 950 x 650 1201Q00A 1211Q00A
R 30 W 2300lm 950 x 650 1201R00A 1211R00A
S 23 W 1700lm 950 x 650 1201S00A 1211S00A
T 17 W 2050lm 950 x 650 1201T00A 1211T00A
U 24 W 1800lm 950 x 650 1201U00A 1211U00A
V 25 W 1900lm 950 x 650 1201V00A 1211V00A
W 38 W 1990lm 950 x 950 1201W00A 1211W00A
X 27 W 2000lm 950 x 900 1201X00A 1211X00A
21 W 950 x 650 1201Y00A 1211Y00A
Y 1550lm
42 W 950 x 950 1201AE00A 1211AE00A
Æ 1800lm
36 W 950 x 650 1201§00A 1211§00A
Ø 1900lm
35 W 950 x 650 1201£00A 1211£00A
A 1990lm
Z 27 W 2000lm 950 x 650 1201Z00A 1211Z00A
We are a UL (Demko)
Customer Test Facility
Stage 2 participant
Artemide S.p.A.
si riserva la facoltà di modificare, in qualunque
momento e senza preavviso, le caratteristiche
tecniche degli elementi illustrati nel presente
catalogo.
Artemide S.p.A.
reserves the right to change, at any time and
without prior warning, the technical specifications
of any product illustrated in this catalogue.
Artemide S.p.A.
se réserve le droit de modifier, à n’importe
quel moment et sans préavis, les caractéristiques
techniques des éléments illustrés dans ce
catalogue.
Artemide S.p.A.
behält sich das Recht vor jederzeit und ohne
Ankündigung die technischen Daten der im
Katalog abgebildetem Produkte zu ändern.
Artemide S.p.A.
se reserva la facultad de modificar, en cualquier
y sin aviso previo, las características técnicas
de los elementos ilustrados en el presente
catálgo.