Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Vuqua - Uv SHF 140

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SHF-140, SHF-180, SHF-290,

SHFM-140, SHFM-180 & SHFM-290

Ultraviolet Water Disinfection Systems from VIQUA

The quality of drinking water can change with time


and become contaminated with harmful bacteria. The
PROFESSIONAL family of compact UV disinfection
systems provide a reliable, economical, and
chemical-free way to safeguard drinking water in any
light commercial application. VIQUA’s products have
been designed and tested to ensure quality drinking
water is at everyone’s finger tips.

Regardless of your need, there is a VIQUA system to


suit your requirements. VIQUA’s High-Flow series
offers systems with flow rates of up to 290 GPM
(65 m3/hr) for facilities with higher water demands.

VIQUA’s line of High Flow UV water disinfection systems


have been specifically designed to extend the flow rate
range of drinking water that can be safeguarded using
the proven and trusted technology already offered by the
VIQUA family of products.

Features of VIQUA UV water disinfection systems

• Equipped to inactivate harmful microorganisms in water • Separate control panel with power isolation.
flows up to 290 GPM (65 m3/hr).
• Visual display of lamp life remaining and audible/visual
• Specially designed and tested Sterilume-HO lamps lamp change reminder.
provide consistent and reliable UV output over the entire
life of the lamp (9000 hours) to ensure continuous • Specialised 254nm UV intensity sensor available
purification. (SHFM models) with output to enable solenoid valve or
remote alarm.
• Superior quality 316 stainless steel chamber.

Replacement Parts

SHF-140 SHF-180 SHF-290 SHFM-140 SHFM-180 SHFM-290

S740RL-4C UV Lamp – – – –

S950RL-4C UV Lamp – –

QS-012 Quartz Sleeve – – – –

QS-180 Quartz Sleeve – – – –

QSO-950 Quartz Sleeve – – – –

254NM-HF UV Sensor – – – –

BA-ICE-HF Controller

BA-ICE-M-HF Controller – – –
Specifications

MODEL
N. America SHF-140 SHF-180 SHF-290 SHFM-140 SHFM-180 SHFM-290

EU CEE 7/7 SHF-140/2 SHF-180/2 SHF-290/2 SHFM-140/2 SHFM-180/2 SHFM-290/2

AUS/NZ 3112 SHF-140/2A SHF-180/2A SHF-290/2A SHFM-140/2A SHFM-180/2A SHFM-290/2A

UK BS 1363 SHF-140/2B SHF-180/2B SHF-290/2B SHFM-140/2B SHFM-180/2B SHFM-290/2B


FLOW RATES (@ 95% UVT)
310 GPM (1170 lpm) 350 GPM (1300 lpm) 543 GPM (2055 lpm) 310 GPM (1300 lpm) 350 GPM (1300 lpm) 543 GPM (2055 lpm)
US Public Health (16 mJ/cm2)
(70 m3/hr) (78 m3/hr) (123 m3/hr) (78 m3/hr) (78 m3/hr) (123 m3/hr)

170 GPM (640 lpm) 210 GPM (790 lpm) 290 GPM (1098 lpm) 170 GPM (640 lpm) 210 GPM (790 lpm) 290 GPM (1098 lpm)
VIQUA Standard (30 mJ/cm2)
(38 m3/hr) (47 m3/hr) (65 m3/hr) (38 m3/hr) (47 m3/hr) (65 m3/hr)

125 GPM (470 lpm) 160 GPM (600 lpm) 215 GPM (813 lpm) 125 GPM (470 lpm) 160 GPM (600 lpm) 215 GPM (813 lpm)
NSF/EPA (40 mJ/cm2)
(28 m3/hr) (36 m3/hr) (48 m3/hr) (28 m3/hr) (36 m3/hr) (48 m3/hr)

DIMENSIONS
34” x 6” x 14” 42.5” x 6” x 14” 42.5” x 8” x 17” 34” x 6” x 14” 42.5” x 6” x 14” 42.5” x 8” x 17”
Chamber (86.4 cm x 15.2 cm x (107.3 cm x 15.2 cm (108 cm x 20.3 cm x (86.4 cm x 15.2 cm x (107.3 cm x 15.2 cm (108 cm x 20.3 cm x
35.6 cm) x 35.6 cm) 43.5 cm) 35.6 cm) x 35.6 cm) 43.5 cm)
17.5” x 19.5” x 8.2” 17.5” x 19.5” x 8.2” 17.5” x 19.5” x 8.2” 17.5” x 19.5” x 8.2” 17.5” x 19.5” x 8.2” 17.5” x 19.5” x 8.2”
Controller (44.5 cm x 50 cm x (44.5 cm x 50 cm x (44.5 cm x 50 cm x (44.5 cm x 50 cm x (44.5 cm x 50 cm x (44.5 cm x 50 cm x
21 cm) 21 cm) 21 cm) 21 cm) 21 cm) 21 cm)
Inlet/Outlet Port Size 3” FLANGE 3” FLANGE 4” FLANGE 3” FLANGE 3” FLANGE 4” FLANGE
Shipping Weight 96 lbs (43.5 kg) 99 lbs (45 kg) 286.5 lbs (129.7 kg) 96.5 lbs (43.7 kg) 99.5 lbs (45.1 kg) 287 lbs (130.1 kg)
ELECTRICAL
Voltage 100-240V / 50-60 Hz 100-240V / 50-60 Hz 100-240V / 50-60 Hz 100-240V / 50-60 Hz 100-240V / 50-60 Hz 100-240V / 50-60 Hz

Power Consumption 350 W 440 W 550 W 350 W 440 W 550 W

Maximum Operating Pressure 125 psi (8.62 bar) 125 psi (8.62 bar) 125 psi (8.62 bar) 125 psi (8.62 bar) 125 psi (8.62 bar) 125 psi (8.62 bar)

Influent Water Temperature 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F)

Number of Lamps 4 4 5 4 4 5

FEATURES
Visual “Power On” YES YES YES YES YES YES

Chamber Material 316L SS 316L SS 316L SS 316L SS 316L SS 316L SS

Visual Lamp Life Remaining YES YES YES YES YES YES

Audible Lamp Failure YES YES YES YES YES YES

Audible Lamp Replacement


YES YES YES YES YES YES
Reminder

UV Sensor NO NO NO YES YES YES

Sensor Reading Output (4-20mA) -- -- -- Optional with 260134 Optional with 260134 Optional with 260134

Solenoid Valve Output -- -- -- Optional Optional Optional

HI-FLO DOSE CHART*


Water Quality Parameters 600

500
Hardness Iron Tannins
FLOW RATE (U.S. gpm)

< 7 grains (120 mg/L) < 0.3 mg/L < 0.1 mg/L 400
HI-FLO 290 Series
300 HI-FLO 180 Series
Cryptosporidium &Giardia HI-FLO 140 Series
eradicated at <10mJ/cm2
200

E. Coli eradicated
100 at 6.6mJ/cm2 1966
US Public Manufacturers NSF/EPA
Health Standard Standard
0
0 5 10 15 20 25 30 35 40 45

UV DOSE (FLUENCE) (mJ/cm2)


*@ 95% UVT and 20°C
Note: dosages based on end of lamp life (0.85 EOLL)

425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1


t. 1.519.763.1032 • f. 1.519.763.5069 • tf. 1.800.265.7246 (US /CAN)
t. +31.73.747.0144 (EUR) • info@viqua.com • www.viqua.com UV Sterilizer
98HA
LIT-520339-R_RevD © 2017 VIQUA - a Division of Trojan Technologies Group ULC E210834