SynergEyes A - Fitting Guide - 75006E
SynergEyes A - Fitting Guide - 75006E
SynergEyes A - Fitting Guide - 75006E
Overview 2
...............................................................................................................................
Patient Candidates 2
...............................................................................................................................
Key Features of SynergEyes® A 3
...............................................................................................................................
SynergEyes® A Lens Design 4
...............................................................................................................................
Diagnostic Set 5
...............................................................................................................................
Key Fitting Principles 6-7
...............................................................................................................................
Normal Corneas 6
...............................................................................................................................
Irregular Corneas 6-7
...............................................................................................................................
Fitting SynergEyes® A 8-10
...............................................................................................................................
Ideal SynergEyes® A Fit on a Normal Cornea 11
...............................................................................................................................
SynergEyes® A Fit on a Keratoconic Cornea 12
...............................................................................................................................
SynergEyes® A Fit on a Post Surgical Cornea 13
...............................................................................................................................
Troubleshooting & Tips for Success 14-19
...............................................................................................................................
Enhanced Profile Lens 20
...............................................................................................................................
SynergEyes® A Fitting Flowchart 21
...............................................................................................................................
Available Parameters back cover
...............................................................................................................................
Contact Information back cover
...............................................................................................................................
1
Overview
Patient Candidates
2
Key Features of SynergEyes® A
SynergEyes ® A
1. 100 Dk rigid gas
permeable center tear layer provides
allows high oxygen
SC
astigmatism correction
LE
RA
transmission to
soft lens skirt is dimensionally
better satisfy stable and expansion-free
corneal uptake
precision optics centered
2. Rigidity of lens
DK RGP
over visual axis
center delivers rotationally stable platform
HIGH
optimal visual acuity
3. Astigmatism IRT A
E
100 Dk RGP center allows
FT R N
correction without
SK
SO C O
1 Data on file. 3
SynergEyes® A Lens Design
8.4 mm
Rigid Center Diameter
14.5 mm
Overall Diameter
Normal Corneas
When fitting the SynergEyes® A lens on normal, healthy corneas,
it is important that the lens always be fit steeper than flat K. A
successful SynergEyes fit results in a lens that rides on a layer of
tears. By creating this tear layer underneath the lens, an effective
tear pump mechanism is produced.
The following fitting principles apply:
· Spherical corneas do well with a base curve 1.00D steeper
than flat K
· Astigmatic corneas (with up to 1.50D of corneal astigmatism)
require a base curve 1.50D steeper than flat K
· Patients with more than 1.50D of corneal astigmatism may
require an even steeper base curve
Irregular Corneas
The appropriate SynergEyes® lens design selection should be
based on the shape of the cornea, not just the patient history
or diagnosis.
right window.
consider ordering the lens in the Enhanced
Profile design.
• For powers greater than those listed, please
Ifuse the online calculator or call consultation
performing a diagnostic evaluation, select
at the number provided below.
the diagnostic lens in the recommended
A Customer Care:
parameters
877-733-2012, option 1
and follow the instructions for
Hybrid Contact Lens for Astigmatism Consultation: 877-733-2012, option 2
www.synergeyes.com
insertion on Page 9.
© 2008 SynergEyes, Inc.
10
Ideal SynergEyes® A Fit on a Normal Cornea
11
SynergEyes® A Fit on a Keratoconic Cornea
Apical Clearance as
Indicated by Fluorescein
Pooling without Touch
Persistent Central
Bubble not Caused by
Insertion Error
12
SynergEyes® A Fit on a Post Surgical Cornea
Fluorescein Pooling
without Bubble
Persistent Central
Bubble not Caused by
Insertion Error
13
Troubleshooting & Tips for Success
Bubbles
Because air bubbles can affect the appearance of the
fluorescein pattern, it is critical to eliminate them prior to
evaluating the fit. A bubble does not necessarily indicate
that the lens is too steep.
14
Troubleshooting & Tips for Success
Bubbles are
indicated by a
very distinct
outer edge
Touch patterns
typically
have a less
defined edge.
15
Troubleshooting & Tips for Success
Central Bearing
16 Base Curve Too Flat - Steepen Base Curve (Ex. 7.7mm BC -> 7.6mm BC)
Troubleshooting & Tips for Success
Lack of
Fluorescein
Excessive
in RGP
Fluorescein
Periphery &
Pooling
Junction Area
Centrally
Fluorescein
Pooling Under
Soft Skirt
Periphery
Base Curve Too Steep - Flatten Base Curve (Ex. 7.6mm BC -> 7.7mm BC) 17
Troubleshooting & Tips for Success
Fluorescein
Pooling Under
the Periphery of
the Soft Skirt
Heavy Bearing
at RGP
Periphery,
with Complete
Absence of
Fluorescein.
18
Troubleshooting & Tips for Success
D PROFILE RIGID CE
ANCE NT
ENH ER
T EA
IR RN
SK CO
FT
SO
SYNERGEYES ENHANCED PROFILE LENS
IR
T EA
RN
SK CO
FT
SO
S TA N D A R D S Y N E R G E Y E S L E N S
20
SynergEyes® A Fitting Flowchart
Use the following flow chart when evaluating the fit of the SynergEyes® A diagnostic lenses.
Determine initial
base curve and skirt curve using
the slide rule, online calculator,
consultation, or topography.
21
Page cut here to
create flap.
IF RESIDUAL
ASTIGMATISM DUE TO
FLEXURE IS OBSERVED:
ce.
Order the thicker,
enhanced profile
design. Patients
nt
arance with higher
amounts of corneal
cylinder may also
en benefit from a
rve steeper base curve.*
Page cut here to
create flap.
For additional information on
fitting SynergEyes® A, please visit
www.FitSynergEyes.com.
SynergEyes® A Parameters
Material Paflufocon D center
(hemiberfilcon A skirt)
Dk 100
Water Content 27% (soft skirt)
Diameter 14.5mm
Base Curve 7.10 to 8.00 in .10mm steps
Skirt Curvature 1.0 (steep) & 1.3 (flat)
Sphere Power +4.00D to -8.00D in .25D steps
-8.50 to -20.00 in 0.50D steps
+4.25 to +8.00 in .25D steps
+8.50 to +20.00 in .50D steps
Wear Indications Daily Wear
Replacement Cycle 6 Month
Lens Care Hydrogen Peroxide
Customer Care
PHONE: 877.733.2012, option 1
Consultation
PHONE: 877.733.2012, option 2
©2009, SynergEyes, Inc. 75006, Rev. E
www.synergeyes.com 877-SEE-2012