TDS Meyco Sa 167 PDF
TDS Meyco Sa 167 PDF
TDS Meyco Sa 167 PDF
date
Mixing Consumption
When MEYCO SA 167 is used for wet mix The dosage of MEYCO SA 167 depends on the
spraying, the w/c+b ratio should be below 0.5 and temperature conditions, reactivity of cement used
preferably less than 0.45. When targeting and on required thickness of layers, setting time
extremely high early strength 0.40 or lower it is and early strength development. The consumption
recommended. The lower w/c+b ratios provide of MEYCO SA 167 is normally in the range of 3 to
faster setting; higher early strength, improved 10 % of binder weight. Overdosing (>10 %) may
durability, lower accelerator dosage and thicker result in decreased final strengths.
layers can be applied over head.
Cleaning of dosing pump
Maximising the efficiency of mixing AFA’s into the
wet-mix concrete stream (and therefore Prior to the use of MEYCO SA 167, the dosing
performance), is achieved at the nozzle using twin pump and other parts of the system must be
compressed air/AFA feeds to the nozzle injector thoroughly cleaned with plenty of water. Failure
as is standard on MEYCO Equipment for sprayed to do so provokes blockages in the dosing
concrete applications. system. Make sure that all operators involved in
testing and application are fully informed.
Dosing system
Storage
MEYCO SA 167 is added in the nozzle. To ensure
a constant and accurate dosage to ensure quality MEYCO SA 167 must be stored at minimum
sprayed concrete, it is crucial to follow the pump +5°C and maximum +35 °C (optimum
selection guideline given below: temperature for storage and performance
+20°C).
Works very well with: MEYCO SA 167 has to be kept in closed
Mono-pumps (screw pumps) containers made of plastic, glass fibre or
Squeeze pumps (Bredel) stainless steel, with periodical remixing/
MEYCO Dosa agitation of the product.
MEYCO SA 167 must not be stored in normal
Should not to be used with: steel containers as the pH can cause corrosion
Piston-pumps that might affect the performance of the
All pumps with ball and seat valves product.
Pressure tanks After prolonged storage we recommend that
Gear pumps MEYCO SA 167 be always fully agitated prior
to use by mechanical stirring or re-circulation
Do not use a filter on the suction hose as this pumping.
causes obstructions. Preferably the material If stored under the above given conditions,
should be drawn from the bottom of the MEYCO SA 167 has a shelf life of 6 months.
drum/container. It is recommended to consult your local
MEYCO representative prior to the use of any
product that has been frozen.
Compatibility with other accelerators
MEYCO SA 167 can be interchanged with BASF’s After prolonged storage, performance testing
alkali-free accelerators MEYCO SA160, 162, 163, should always be carried out before use.
164, 169, 172, 173, 175, 176, 180 and 181.
However, storage of mixed MEYCO SA
accelerators is not recommended. BASF’s alkali-
free accelerators shall not be mixed with any other
type of BASF accelerator other than those listed
above.
Safety precautions
The same precautions as with handling and use of
cementitous products should be observed:
The information given here is true, represents our best knowledge and is based not only on laboratory work but also on field experience.
However, because of numerous factors affecting results, we offer this information without guarantee and no patent liability is assumed.
For additional information or questions, please contact your local representative.
Headquarter: