ACUSON X150™ Ultrasound System: Release 2.5
ACUSON X150™ Ultrasound System: Release 2.5
ACUSON X150™ Ultrasound System: Release 2.5
ACUSON X150™
Ultrasound System
Release 2.5
www.siemens.com/ultrasound
This page left intentionally blank.
2
TABLE OF CONTENTS
GENERAL INFORMATION
The ultra-compact ACUSON X150™ ultrasound
system offers unparalleled diagnostic confidence
and clinical performance. Maximum upgrade
flexibility and exceptional system reliability
safeguard your investment for years to come and
allow you to grow as clinical applications evolve
or patient needs change over time. Intelligent
features improve workflow, while our ergonomic
system design makes ultrasound exams easier,
faster and more comfortable than ever before.
The ACUSON X150 system was designed to
meet the everyday clinical requirements of
private practices as well as dynamic hospital
environments. From OB/GYN, early pregnancy 3-Scape™ real-time 3D imaging, productivity
and reproductive medicine to abdominal imaging enhancing technologies including phase inversion
and more, the ACUSON X150 system provides you Tissue Harmonic Imaging (THI) and TGO™ tissue
with clinical application flexibility. grayscale optimization technology and connectivity
solutions such as DICOM Print/Store, DICOM Worklist,
System Architecture DICOM MPPS and DICOM OB/GYN SR.
All-digital signal processing technology provides
User Interface
best-in-class 2D and Doppler image quality for
greater diagnostic confidence. • Intuitive PC-based operating principles
• User-centric control panel with home-base layout
New generation all-digital beamformer technology
• On/Off tasklight and back-lit illumination of
enables parallel Quad beam processing of the RF
control panel
signal data in the time and amplitude domains.
• Variable brightness indicates active state of
• 2D-mode line density: Up to 256 lines
function keys
• Processing channels: Up to 4,480 channels
• Customizable Soft Key selections are displayed
• Total system dynamic range: > 175 dB on-screen to provide easy and immediate access
The DIMAQ-IP integrated workstation provides to imaging controls and activation of specific
digital acquisition, storage, review and transfer functions
of ultrasound studies. Studies can be reviewed, • On Screen Menus (OSM) provide easy and
quantified and stored on the system hard drive immediate access to secondary imaging controls
and transferred to the built-in CD/DVD R/W or to an • Easily accessible, full-size QWERTY keyboard
external hard drive using USB 2.0 (SN > 330000) for for text entry, function keys and system
cost-effective archival. programming
• Trackball integrated into the control panel
The flexible system architecture enables seamless
integration of additional application functionality • Wrist support to help reduce operator repetitive
such as Color Imaging, Cardiac Screening and stress injuries
4
• Up to 32 QuickSet™ user-programmable Hard Drive
system presets allow for individual transducer/ • Internal 160 GB hard drive
application settings. QuickSet presets combine • Allows storage of patient studies that include
all preferred imaging mode parameters, images, reports and measurements
annotation text and measurements into one user
• Image storage capacity up to 150,000 images
preset.
with compression (B/W and color)
Language Support
DVD Multi-Drive (DVD±R/RW & CD/RW)
• On-screen text, control panel overlay and
• Removable 4.7 GB single layer DVD
operating instructions are all available in
• Removable 650 MB, 700 MB and 790 MB CD-R
Chinese, English, French, German, Italian,
and 650 MB or 700 MB CD-RW
Russian and Spanish
• Allows storage and archiving of complete patient
-- Additional Instructions for Use are available
studies including images, dynamic clips, reports
in the following languages — Czech, Danish,
and measurements
Dutch, Finnish, Greek, Hungarian, Korean,
Latvian, Lithuanian, Norwegian, Polish, • Storage capacity dependent upon patient study
Portuguese, Romanian, Russian, Slovak, size
Swedish and Turkish • Export of images in TIFF, JPG or DICOM format,
-- Allows Chinese character input in Patient clips in AVI or DICOM format and reports in PDF
Registration format
-- Allows for Russian character input • Export of summary reports in PDF and RTF format
• DICOM viewer for export of DICOM format to CD/
Monitor
DVD
• Flat Panel Display, 15-inch color, high resolution,
• DICOM viewer is Vista compatible
and progressive scan (non-interlaced) with in
plane switching (IPS) technology Transducer Ports
• Resolution: 1024 x 768 pixels • Up to 3 active universal transducer ports that
• Total screen area: 1024 x 768. support phased array, curved array and linear
array transducers (optional third array port)
• Recordable image area clips 800 x 600
• Electronic transducer selection (instantaneous
• Total screen capture is an option.
switching between transducers)
• Monitor tilt: 10° up, 75° down and swivel of ±80°
• Industrial design provides easy access to the
• Digital on-screen display brightness and contrast
transducer ports
controls
• Energy saving display power management Transducer Storage
5
• Special transducer holder provides secure • Transmit frequencies: Up to 7 frequencies
storage and easy access to endocavity transducer -- 2D and M-mode: Up to 3 frequencies
• Transducer holders can be removed for cleaning -- THI: Up to 2 frequencies
System Review -- Color, power, or pulsed wave Doppler: Up to 2
• (4) multi-directional swivel wheels for easy frequencies
mobility Focusing
• (4) swivel locking brakes (one for each wheel) • Transmit focal zone: Up to 4 zones
Acoustic Output Management • Digital dynamic receive focusing with dynamic
• On-screen acoustic power indicator (AIUM/NEMA apodization
output display standard) Synthetic Aperture
• Synthetic Aperture technology is available on the
OPERATING/DISPLAY MODES CH5-2 and VF10-5 transducers for higher image
resolution at depth
• 2D imaging in fundamental and harmonic modes
• User can turn Synthetic Aperture On and Off
• M-mode
• Color Doppler Velocity mode 2D Image Processing
• Power Doppler mode • All-digital parallel signal processing with frame
• Pulsed Wave (PW) spectral Doppler mode rates up to 498 F/sec (transducer dependent)
6
• Virtual Format Imaging
-- Left/Right steer
-- Trapezoid Imaging
• Digital read/write zoom with image pan
-- Available on live and cine replay images
-- Up to 10x zoom (transducer dependent)
• 90° image rotation on orthopedic of the VF10-5
transducer
• Velocity scale range: ±350 cm/sec with 0º angle • Time Average Velocity (TAV) max
correction • Systolic/Diastolic (S/D) ratio
• Angle correction: 0 - 89º in 1º increments • Velocity Time Integral (VTI)
• Gate size: 1.0 – 20 mm • Acceleration/Deceleration
7
• Flow volume using combined velocity and • Power smoothing: 4 levels
distance, or velocity and ellipse measurements • Tissue/color priority: 5 selections
• Doppler angle correction after measurement • Color persistence: 5 levels
Color Doppler Velocity Imaging • Color invert
• Available on all imaging array transducers Color and Power Doppler Display
• Multi-Beam Formation technology provides • 2D/C mode, Split 2D-2D/C mode
parallel signal processing for high color Doppler • Dual real-time 2D/C mode
frame rates (transducer dependent)
• 2D/C/D mode (simultaneous triplex), 2D/C/D
• Left/right steer on all linear transducers mode (update)
• Advanced processing in color mode resulting in
M-mode
excellent spatial resolution and superior flash
suppression • Available on all imaging array transducers
8
FREEZE, CINE CLIP FUNCTIONS -- Angle correct
-- Measurements/reports/annotations/pictograms
Cine Store
• M-mode
• Multiple frame storage with clipboard review
-- Gray map
allowing post-processing, measurement and
-- M-mode colorization map
annotation functions
-- Measurements/reports/annotations/pictograms
• Prospective clip capture during real-time imaging
in two compression rates up to
120 sec or 3600 frames
TRANSDUCER TECHNOLOGY
Cine Review Ultra-sensitive, wideband transducers, matched
with user-selectable MultiHertz imaging, improve
Cine feature is standard and offers post-acquisition
resolution and penetration. Depending on the
optimization of all real-time post-processing
transducer, the user can select up to five 2D and
functions.
THI frequencies and two color and spectral Doppler
• Frame-by-frame cine loop review and continuous frequencies, expanding the clinical versatility of
cine motion review, including control of a single transducer, and thereby maximizing
playback rate transducer investment.
• Independent cine review in mixed modes (2D/M,
• Wideband MultiHertz imaging allows user-
2D/Doppler, 2D/C/Doppler)
selection of independent 2D and color
• Independent cine review in 2D Dual Select mode frequencies for optimal resolution and
with image align playback feature penetration
• Standard cine memory is up to 2729 frames • Reusable, stainless steel and disposable biopsy
• Up to 30 seconds Doppler cine, or up to 16 guides for specified linear and curved array
seconds M-mode cine transducers
Post Processing Features in Freeze Frame • Innovative ultra low-loss lens materials and
• 2D-mode microelectronic technologies for efficient
performance and increased signal bandwidth
-- Zoom/pan
• Frequency range: 2.0 – 13.0 MHz
-- Gray map
• Hanafy lens acoustic technology
-- 2D-mode colorization map
• microCase™ transducer miniaturization
-- Measurements/reports/annotations/pictograms
technology and SuppleFlex cables
• Color Doppler
Note: See dedicated transducer flyer for more information.
-- Zoom/pan
-- Color map
APPLICATIONS
-- Color invert
-- Measurements/reports/annotations/pictograms The ACUSON X150 system is designed to support
a wide range of general and specialty imaging
• Spectral Doppler
applications. Factory-supplied exam and transducer
-- Gray map
dependent imaging presets have been carefully
-- Doppler colorization map
9
optimized for each application to provide Obstetrics
consistency, reliability, and increased productivity • Early Obstetrics Menstrual Age (MA)
measurements are MSD, CRL and Yolk Sac
• Abdominal
• Menstrual Age parameter labels are MSD, CRL,
• Renal
BPD, OFD, HC, AC, ATD, ASD, FL, HL, UL, TL, FT,
• Obstetrics
FTA, and BN
• Reproductive Medicine (Gynecology)
• (10) user-defined labels are available in 2D-mode
• Cardiac
• Calculations include: EFW from the selected
• Early obstetrics reference, Williams EFW%, HC/AC, TCD/AC, LVW/
• Vascular (C-Vas, P-Vas, Venous) HW, CorBPD, FL/AC, FL/BPD, CI, AFI, AXT and
• Small Parts (Breast, Testes, Thyroid) Fetal Heart Rate
• Orthopedics • Fronto Maxillary Facial Angle
• Musculoskeletal • Customizable anatomy descriptors
Selected applications include body markers, text and • Calculations for both Gestational Age (GA) and
annotation labels, worksheets and reports. ultrasound menstrual age and Estimated Date of
Confinement (EDC)
• Early Obstetric patient report and Standard
EXAM-SPECIFIC MEASUREMENTS Obstetric patient report include a worksheet for
AND CALCULATIONS viewing the progress of the report during the
All measurement and report packages are available exam process and to edit the report
for use with all exam types. • Multiple fetus reporting capabilities
• Growth Analysis Graphs with exam file linking
All exam specific measurement and reports support:
• Obstetric patient report and worksheet including
• All general measurements and calculations Fetal Heart report page
• Comprehensive, customizable, patient reports
Gynecology
and worksheets
• Micturated and residual volume calculation
• Customizable Anatomy Descriptions
• Uterus, right and left ovary measurements,
• Physician summary utility – supports on-system
including ovarian volume
report generation including customizable
• Easily track 15 right follicles and 15 left follicles,
letterhead, patient data, results, graphs,
including follicular volume
images, comments, recommendations and a
customizable signature line. • Gynecology volumes automatically populate to
the report
The following Measurements and Reports packages • DICOM SR for Gynecology (GYN)
are available on the ACUSON X150 system:
• Gynecology patient report
Abdomen Cardiac
10
• M-mode slope, heart rate, time and distance
measurements
• Doppler acceleration, trace, heart rate, time and
velocity measurements
• Cardiac patient report and worksheet for
2D-mode, M-mode and Doppler
• AO/LA or LA/AO calculation
Cerebrovascular (C-Vas)
• CCA, ICA1, ICA2, ICA3, ECA, and VA
measurements
• Area Percent Stenosis and Diameter Percent
Stenosis measurements
• Cerebrovascular patient report
*Software sold separately by Telexy Healthcare and requires a wireless or LAN connection.
11
• Compatible with removable 4.7 GB single layer Cardiac Screening
± DVD Software installable license to enable phased array
• Hard drive capacity: imaging capabilities for adult and pediatric cardiac
-- Approximately 150,000 B/W and color images screening with the P4-2 and P8-4 transducers
-- Approximately 40,960 two-second clips (Requires Color Imaging Option).
12
DICOM–Modality Performed Procedure Step curved and phased array transducers offered on
(MPPS) the ACUSON X150 system are compatible with the
Enables automatic exchange of “Modality Performed additional array port.
Procedure Step” information with the Hospital/
Radiology Information System (HIS/RIS) Barcode Reader
(requires DICOM 3.0 Connectivity option and DICOM • Allows fast and accurate patient information
Modality Worklist option). data input
• Easy attachment to USB port
DICOM OB Structured Reporting (SR)
• Supports 2D and 1D patient barcode
DICOM OB provides a standardized report
• Inputs
architecture to allow for easy transfer of OB
-- Patient Name
measurements to offline PCs, workstations and
archiving systems. DICOM OB will automatically -- Patient ID
populate OB measurements to their respective -- Physician ID
fields in an external software package. (To send the • MOTOROLA Symbol DS6707-HD Barcode Reader
DICOM OB SR data over network the DICOM 3.0
Wireless Data Transfer
connectivity option is required).
Utilizes USB dongle to enable wireless connectivity
TGO Tissue Grayscale Optimization Technology between the ultrasound system and the facility’s
LAN to provide functionality equivalent to a wired
TGO technology provides one-button image
network.
optimization. It automatically adjusts all imaging
B-mode parameters to the tissue type being
The Wireless Option supports connectivity with:
imaged. TGO technology improves the consistency
• DICOM services - Modality worklist, print,
and quality of ultrasound imaging to enhance
storage commitment and store
productivity by removing time-consuming and
operator dependent manual adjustments. TGO • Telexy Q-view*
technology can be used with every transducer, for Technical Specifications
every exam type and at every imaging frequency,
• Standards : IEEE 802.11n, 802.11g, 802.11b,
including THI.
802.11a
• Security features: WEP, WPA, WPA2 personal,
3-Scape Real-Time 3D Imaging
WPA and WPA2 Enterprise
3-Scape 3D imaging provides real-time
reconstruction of 3D images during freehand Ultrasound System Security – Virus Protection
acquisition. Embedded virus protection solution that protects the
system against advanced persistent threats, viruses,
Additional Array Port malware and other executing software by detecting
The additional array port option adds a third active and preventing any unwanted change to improve IT
array port to the ACUSON X150 system and allows compliance and security.
the user to connect up to three linear, curved and
phased array transducers simultaneously. All linear,
13
DOCUMENTATION DEVICES System Interface Connections
• Network
Optional On-Board Video Devices -- (1) Ethernet connector, type RJ45 (10/100
• Up to two (B/W printer & color printer/VCR) BaseT)
documentation devices can be integrated into • Peripherals
the system cart and controlled from the system
-- (1) Serial port RS232-C connector, D-SUB
control panel
(9-pin)
• Supported devices:
-- (2) USB ports 2.0 ports (SN > 330000), Series
-- Mitsubishi P95 USB B/W Printer A-type
-- SONY UP-D897 USB B/W Printer -- (2) AC Main Outlet
-- Mitsubishi CP900UM Color Printer (NTSC)
-- Mitsubishi CP900E Color Printer (PAL) SYSTEM DIMENSIONS
-- USB Inkjet Printer
• System height: 135 cm (53.15 in) – 156 cm
-- Mitsubishi MD3000UM S-VHS VCR (NTSC) (61.42 in) - upright FPD
-- Mitsubishi MD3000E S-VHS VCR (PAL) • Width: 89 cm (35 in) – when the monitor is fully
-- JVC BD-X201MS DVR extended to the left or right
• Depth: 85 cm (33.5 in)
SYSTEM INPUT/OUTPUT • Weight: 90 kg (198.4 lbs)
• User-select monitor height adjustment
Video Standard
-- Monitor lowest position: 135 cm (53.1 in) -
• PAL/CCIR: 625 lines, 50 Hz
measured to top of monitor
• NTSC/EIA: 525 lines, 60 Hz
-- Monitor highest position: 156 cm (61.4 in) -
Video/Audio Input measured to top of monitor
• (1) Composite color Video in, BNC-type
• (1) Y/C Video in, S-terminal (SVHS)
• (1) 2-Channel Audio in (Right/Left), RCA jack type
Video/Audio Output
• (1) Composite B/W Video out, BNC-type
• (1) Composite Color Video out, BNC-type
• (1) RGB & Composite Sync out, mini D-SUB
(15-pin)
• (1) Y/C Video out, S-terminal (SVHS)
• (1) 2-Channel Audio (Right/Left), RCA jack type
• (1) VGA out, mini D-SUB (15-pin)
Other Input/Output
• (1) Foot switch connector, phone jack-type
• (1) Remote control connector, mini jack (stereo)
14
ELECTRICAL/ENVIRONMENTAL Acoustic Output Standards
SPECIFICATIONS • IEC 61157 (Declaration of Acoustic Power
• AIUM/NEMA UD-2, 1998 Acoustic Output
The ACUSON X150 system is available in one
• Measurement Standard for Diagnostic
mainframe configuration, suitable for use in
Ultrasound
100/115V and 230V environments.
• AIUM/NEMA UD-3, 1998 Standard for Real-Time
• Power connections: Display of Thermal and Mechanical Acoustic
-- 100-120/200-240 VAC, 50/60Hz Output Indices on Diagnostic Ultrasound
• Built-in AC isolation transformer Equipment
• Power consumption: maximum 600VA with CE Declaration
OEM’s
This product is provided with a CE marking in
• Atmospheric pressure range: 700 – 1060 hPa accordance with the regulations stated
(525 – 795 mm Hg) or up to 3050 m (10,000 ft) in Council Directive 93/42/EEC of June
• Ambient temperature range (without OEM’s): 14,1993 concerning Medical Devices. 0123
+10° – +40° C (50° – 104° F) The CE marking only applies to medical
• Humidity: 30 – 80%, non-condensing, during devices that have put on the market according to
operation the above reference Council Directive. Unauthorized
• Maximum heat output: 2150 BTU/hr changes to this product are not covered by the CE
marking and the related Declaration of Conformity.
STANDARDS COMPLIANCE
Authorized EC Representative
The ACUSON X150 system meets the requirements Siemens AG, Healthcare Sector
of the Medical Device Directive and carries the CE Henkestrasse 127, 91052 Erlangen, Germany
Mark. phone: +49 9131 84 0
15
3-Scape, ACUSON X150, DIMAQ, microCase,
MultiHertz, QuickSet, SuppleFlex and TGO
are trademarks of
Siemens Medical Solutions USA, Inc.
www.siemens.com/healthcare