Ex - No.3 (A) Open Circuit Characteristics of DC Shunt Generator
Ex - No.3 (A) Open Circuit Characteristics of DC Shunt Generator
Ex - No.3 (A) Open Circuit Characteristics of DC Shunt Generator
3(a)
AIM:
To obtain the open circuit characteristics of DC shunt generator and find
It’s critical resistance.
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter (0-1)A MC 1
2 Voltmeter (0-300)V MC 1
3 Rheostats 1250W, 0.8A Wire Wound 2
4 SPST Switch - - 1
5 Tachometer (0-1500)rpm Digital 1
6 Connecting Wires 2.5sq.mm. Copper Few
PRECAUTIONS:
1. The field rheostat of motor should be in minimum resistance position at the time of
starting and stopping of the machine.
2. The field rheostat of generator should be in maximum resistance position at the time of
starting and stopping of the machine.
3. DPST-1 should be kept open during starting and stopping of the machine
TABULAR COLUMN:
Field Armature
S.N
Current Voltage
o.
If (Amps) Eo (Volts)
MODEL GRAPH:
Eo (Volts)
If
Eo
If (Amps)
PROCEDURE:
VIVA QUESTIONS:
1. What is the difference between a separately excited dc generator and shunt generator?
2. If a DC shunt generator fails to build up voltage, what may be the probable reasons?
3. What is SPST? What is its use in this experiment?
4. What is the reason the presence of residual magnetism in the field poles?
5. Why does the terminal voltage decrease as the load current increases?
6. What is the need for starter in a d.c motor?
7. How does a 3-point starter function?
8. Why is motor rheostat kept in minimum position at starting?
9. Why is generator rheostat kept in maximum position at start up?
10. What is residual voltage? How is it measured?
11. What is critical resistance? How can it be determined?
12. What are the conditions necessary for voltage build up in a d.c shunt generator?
13. What is critical speed?
14. Explain the shape of the O.C.C.
RESULT:
Thus open circuit characteristics of DC shunt generator are obtained and its critical
resistance is determined.