Example 9: Reinforced Concrete Footings: Example of Isolated Footing
Example 9: Reinforced Concrete Footings: Example of Isolated Footing
1
Example 9: Footing Design
If an opened model exists, the module will ask you if you wish to save your previous model.
Once opened the new file, you can proceed with the introduction of data in the left window,
following the order that is shown next.
2) Entering Units
Select the option Units system. This action will display the following drop down menu.
3) Design Code
Select the design code to be used.
Select the Spread footing type and the Concrete column type
2
Example 9: Footing Design
Note. - The introduced value is in the default units. To enter data in other units of the same system,
type the value followed by the desired units to use and press Enter.
The footing base geometry (length, width and height) is not required to be defined because the
program may suggest it. Only enter values to use fixed and predefined values.
When initiating the module the displayed dimensions are default initial values.
3
Example 9: Footing Design
Select the option Column location relative to footing geometry c.g. to locate the column in the plane
of the footing.
Then choose the Centered option.
Enable the Consider column reinforcement and Show dowels options that will be used to determine
the splice lengths.
Enter the amount legs for each direction, the bar diameter to be used and the separation
between stirrups.
Note. - The introduction of these data is optional. To disable it, deactivate the check box Consider
column reinforcement and Show dowels.
4
Example 9: Footing Design
7) Soil Data
The first option in this folder is Calculate soil bearing capacity. By default the program displays the
option disabled. With this option checked the program will require other data necessary for
calculating the soil bearing capacity.
Enter the allowable soil stress. This will define basically the footing dimensions.
Enter the modulus of subgrade reaction; this will be used to determine the base elastic settlements.
Note. –Each variable or option has a sensitive help with its description and definition.
5
Example 9: Footing Design
One load condition (dead load) and two load combinations (service and design) are defined by
default.
In this example we will add manually the condition of live load. Click in the first empty cell of the
column ID, enter an identifier of the condition (i.e., LL). Write a brief description of the load and
finally select a category by double clicking in the cell of the column Category (chose LL).
6
Example 9: Footing Design
Manually enter the new load condition. Notice that when entering a new load condition this is added
automatically in the combinations.
Note. - Also load conditions can easily be added by pressing the button , this option displays a
list of the more often used load conditions.
Next define the combinations:
7
Example 9: Footing Design
Enter the load factors and define the type (service or design).
To automatically generate load combinations, follow the following steps:
1.- Press the Generate load combinations command in the Load management group on the Home
tab. The dialog to generate the load combinations will appear.
2.- Select the file for the generation, as it is shown in the following figure.
8
Example 9: Footing Design
Select the load combination according to the code that is being used, in this case ASCE 7-05 service
load combos.rag, and immediately it will obtain a list of service combinations. Press Generate.
A message with the number of generated load combinations will appear. Press OK.
Notes
If the module is run from RAM Elements, the generation of load combinations or conditions will not
be necessary, because the main program may export all the loads directly to the module. In any case
the loads may be edited or changed in the module.
If it requires eliminate load conditions or combinations, this can easily be done by pressing the
button . A window will display where is possible to select the elements to eliminate.
9) Entering Loads
Locate the Loads folder and select the option Forces by load condition.
9
Example 9: Footing Design
Press OK after entering the forces for the different load cases.
Note. – The loads may be imported directly from the main program.
Define the localization of the horizontal forces.
Select the data Design criterion of footing dimensions and choose Long/Width Ratio (default value)
from the drop menu.
10
Example 9: Footing Design
Select the dowels force type. Use this option when the load is predominantly in compression.
Select the Bars size for footing optimization to be used in the optimization.
Press the Advanced command located in the Options group on the Home tab to display the
Advanced options dialog.
11
Example 9: Footing Design
Configuration window. Leave it with the values by default and click in accept.
In order to obtain the suggested dimensions of the base, press the Suggest footing dimensions
command located in the Process group on the Home tab.
12
Example 9: Footing Design
In the data window and in the detailing window the footing dimensions are shown.
Note. – When several load conditions or combinations are used there may be a small delay in the
calculations.
Press the Optimize command in the Process group on the Home tab. Note that the
reinforcement obtained will be according to the bars selected for the optimization (see step 10).
13
Example 9: Footing Design
reinforcement fulfill all requirements of the Specifications. Press the Check command in the
Process group on the Home tab.
Check the traffic lights in the status bar located at the lower right of the screen.
Note. - Remember that a yellow traffic light indicates warnings, while a red light indicates errors.
FEM Diagram of contact pressures. Also it is possible to see a FEM diagram of settlements.
14
Example 9: Footing Design
This screen displays a spreadsheet with the reinforcement data that may be edited or changed
according to your requirements. After modifying the reinforcement, check the design with the Check
If the user wants to return to the initial results of automatic design, the Optimize command can
be used.
If the type of column is pedestal the program may suggest its reinforcement, too.
These diagrams can be exported to a CAD program pressing the RE button and selecting the Export
to DXF option. .
15
Example 9: Footing Design
In order to see the report, press the Report command located in the Process group in the Home
tab and in the Quick access toolbar.
The report consists of 3 sections:
• General data. Relative to the base geometry, the used materials, the soil foundation
properties, the provide reinforcement, etc.
• Results. Relative to the footing-soil interaction and the footing strength as a reinforced
concrete element.
• Explanatory notes
Press the Print command located in the group Print in order to print the report
Note.- If you wish to edit the report, you can easily export it to Microsoft Word or Microsoft Excel
using the Export group options.
16
Example 9: Footing Design
17