Step by Step Instruction (Solax Smart Meter With CT Sensor) : Meter Terminal 7: White-Brown Meter Terminal 8: Brown

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

STEP BY STEP INSTRUCTION

(SOLAX SMART METER WITH CT SENSOR)

1. Connect terminal 1 to terminal 2. 2. Connect terminal 1,2 to Line side main breaker
Connect terminal 3 to terminal 4. Connect terminal 3 ,4 to Neutral side main breaker
(use AWG 10 cable) (use AWG 10 cable)

L N

Main Breaker

Load Side

3. Connect black ct-sensor wire to terminal 5. 4. Clamp CT sensor on main service cable. Arrow must be pointing outside the
Connect white ct-sensor wire to terminal 6. grid.

ct sensor clip here


arrow
pointing
outward
L N

load side

5. Prepare RJ45 cable 6. Crimp the end using standard RJ45


7. Plug to the inverter meter port
color code designation.

8. Screw the other end of the RJ45 cable 9. Set the limiter function of the inverter.
to the smart meter.
On the inverter main menu press enter
meter terminal 7: white-brown choose "settings"
meter terminal 8: brown password: 2014

Expot control: ENABLE


VALUE: 00000