Structure Scope
Structure Scope
Caisson inspec
3.1 Caisson body from below sump deck to splash zone
3
3.2 Caisson support
4.1
4 Jacket leg from below cellar deck to splash zone
4.2
Leg to pile connection/ crown
Flare/ vent boom in
- Baseline inspection General Visual inspection and Welding/ pit gauge, camera/
- Periodic inspection NDT (ACFM or MPI and UTG) toughpad, measurement
(based on CIMG every 4 tape, ACFM equipment or
years) MPI yoke (with
consumables) and UT set (A
scan)
Conductors inspection
Close visual inspection and Abseiling gears, camera,
-Baseline inspection UTG at 4 direction measurement tape, UT set
'- Periodic inspection (A scan)
(based on CIMG every 4
years)
Caisson inspection
Abseiling gears, camera,
-Baseline inspection measurement tape, UT set
'- Periodic inspection Close visual inspection and (A scan)
(based on CIMG every 4 UTG at 4 direction
years)
Remaining thickness,
corrosion, cracks, damage,
variation of design, missing/
loose members
Remaining thickness,
corrosion, cracks, damage,
variation of design, missing/
loose members
Remaining thickness,
corrosion, cracks, damage,
variation of design, missing/
loose members
Remaining thickness,
corrosion, cracks, damage,
variation of design, missing/
loose members
Remaining thickness,
corrosion, cracks, damage,
variation of design, missing/
loose members