(Identical with ASTM Specification A 210/A 210M-95 except for editorial differences in Table 2) 98
309
www.worldironsteel.com info@worldironsteel.com
310
www.worldironsteel.com info@worldironsteel.com
o’clock positions on Grade C tubing with sizes of When properly manipulated, superheater tubes shall
2.375 in. [60.3 mm] in outside diameter and smaller stand all forging, welding and bending operations neces-
shall not be considered a basis for rejection. sary for application without developing defects.
12.3 Flaring Test — One flaring test shall be made
on specimens from each end of the one finished tube
from each lot (Note 2,) but not the one used for the
flattening test.
12.4 Hardness Test — Brinell or Rockwell hardness 14. Product Marking
test shall be made on specimens from two tubes from
14.1 In addition to the marking prescribed in Specifi- 98
each lot (Note 3).
cation A 450/A 450M, the marking shall indicate
12.5 Hydrostatic or Nondestructive Electric Test — whether the tube is hot-finished or cold-finished.
Each tube shall be subjected to the hydrostatic, or,
instead of this test, a nondestructive electric test may
be used when specified by the purchaser.
311
www.worldironsteel.com info@worldironsteel.com
TABLE 1
CHEMICAL REQUIREMENTS
Composition, %
98 TABLE 2
NUMBER OF TUBES IN A LOT HEAT TREATED BY
THE CONTINUOUS PROCESS
2 in. (50.8 mm) and over in diameter not more than 50 tubes
and 0.200 in. (5.1 mm) and over in
wall thickness
2 in. (50.8 mm) and over in outside not more than 75 tubes
diameter and under 0.200 in. (5.1
mm) in wall thickness
Less than 2 in. (50.8 mm) but over 1 not more than 75 tubes
in. (25.4 mm) in outside diameter or
over 1 in. in outside diameter and
under 0.200 in. (5.08 mm) in wall
thickness
1 in. (25.4 mm) or less in outside not more than 125 tubes
diameter
312
www.worldironsteel.com info@worldironsteel.com
TABLE 3 98
TENSILE REQUIREMENTS
TABLE 4 98
COMPUTED MINIMUM ELONGATION VALUESA
Elongation in 2 in. or
Wall Thickness, in. [mm] 50 mm, min, %
5⁄ (0.312) [8] 30
16
9⁄ (0.281) [7.2] 28
32
1⁄ (0.250) [6.4] 27
4
7⁄
32 (0.219) [5.6] 26
3⁄
16 (0.188) [4.8] 24
5⁄
32 (0.156) [4] 22
1⁄ (0.125) [3.2] 21
8
3⁄
32 (0.094) [2.4] 20
1⁄
16 (0.062) [1.6] 18
0.062 to 0.035 [1.6 to 0.9], excl 17
0.035 to 0.022 [0.9 to 0.6], excl 16
0.022 to 0.015 [0.6 to 0.4], incl 16
A Calculated elongation requirements shall be rounded to the nearest whole number.
313