The document discusses various alarm and monitoring systems including different types of data stations, data converters, displays and control units.

The different types of data stations mentioned are AHD-SAS 15, AHD-PS 47, AHD-PS 30, AHD-PS 15, and AHD-R 101.

The AHD-SAS 15 data station can connect to sensors for 4-20mA signals, contacts, PT100/PT1000 temperature sensors, thermocouples, and voltages between 0-5V, 0-10V, and 0-30V.

Alarm & Monitoring Systems

Modular System

Display Display

CAN-Bus

Data station Data station Data converter


Alarm & Monitoring Systems

Data stations
 AHD-SAS 15
 AHD-PS 47 / AHD-PS 30 / AHD-PS 15
 AHD-R 101
 AHD 882
Alarm & Monitoring Systems

Data converter
 AHD-UIC
 AHD-UCC
Alarm & Monitoring Systems

Displays with integrated PC, Monitors


 AHD 1019 M
 AHD 1015 TC
 AHD 919
 AHD 915 TC
Alarm & Monitoring Systems

Display and Control Units


 AHD 651 Accessories
 AHD 880 TC  AHD 650 R
 Kompakt EDA 47
Alarm & Monitoring Systems

Data stations
 AHD-SAS 15
 AHD-PS 47 / AHD-PS 30 / AHD-PS 15
 AHD-R 101
 AHD 882
AHD-SAS 15 Data station

CAN

2 serial
2 serial
inputs
outputs

15 inputs
for analog and binary sensors
AHD-SAS 15 Data station

15 input channels individually


fitted with pluggable analog
input modules for acquisition
of analog and binary signals

Input/Sensor signal Type Analog active passive


module/
Article number
4-20 mA, 2-pole sensor B / 11109 x
- Sensor without external power supply
4-20 mA, 4-pole sensor C / 11110 x
- Sensor with external power supply
Contact via voltage measurement E / 11111 x
- Contact switches UBat
Contact potentialfree, F / 11112 x
- Contact switches UBat-
- Transistor switches UBat-

15 inputs PT100
- Resistance sensor, Measuring range -50°C … +200°C
G / 11119 x

for analog and binary sensors PT1000 H / 11120 x


- Resistance sensor, Measuring range -50°C … +200°C

Thermo couple NiCrNi, Type K I / 11121 x


Measuring range 0°C … +1000°C
Voltage 0 – 5 V DC J / 11122 x
Voltage 0 – 10 V DC K / 11123 x
Voltage 0 – 30 V DC (discontinued) L / 11124 x
Voltage 0 – 40 V DC T / 13142 x
Racor/Parker water level sensor M / 10893 x
AHD-SAS 15 Data station

Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station

Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station

Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station

Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station

Applicable as autarkic
alarm and monitoring system

System operates independently


from other components
Alarm signaling also at complete shutdown
of system bus

Local alarm indications by LED´s

1 Horn relay output


1 Common alarm relay output
2 free configurable relay outputs
1 Acknowledgement input for external alarm
acknowledgement
AHD-SAS 15 Data station

Configuration via PC Software

Configuration via CAN-BUS-Line

• Measuring point text (2 languages applied)


• Unit
• Standardization (i.e. Tank curve)
• Indication range / Validity range
• Wire breakage monitoring
• Alarm signaling / Alarm limits
(min./max. Alarm, Warning)
• Alarm delay
• Alarm suppression
• Filter settings (rising/ trailing edge)
AHD-SAS 15 Data station

Internal measuring value processing

All acquired measuring data are internally


processed and standardized.

On demand, special characteristic curves


can be applied by configuration, i.e. for non
linear sensors or tank content
measurements.

Additionally it is possible to create virtual


channels, whose resulting values are
calculated from multiple physical sensors.
A virtual channel may be used e.g. for
calculation of total fuel reserve by
summation of several tank contents or
mean value calculation of exhaust gas
temperatures.
AHD-SAS 15 Data station

Integrated alarm memory

An integrated alarm memory may record


up to 10,000 messages within a data
station AHD-SAS 15.
These may be warning, alarm, sensor
fault or also status messages.
The storage considers here all locally
arising events and stores them with date,
time, duration and acknowledgement
state. The readout of memory can be
performed locally via existing RS232
interface.
(Readout via CAN-BUS in progress).
Alarm & Monitoring Systems

Data stations
 AHD-SAS 15
 AHD-PS 47 / AHD-PS 30 / AHD-PS 15
 AHD-R 101
 AHD 882
AHD-PS 47 Binary data station

3 serial
outputs

47 binary inputs
AHD-PS 15 / AHD-PS 30 Binary data stations

3 serial 3 serial
outputs outputs

15 binary inputs 30 binary inputs


AHD-PS 47 / PS 30 / PS 15 Binary data station

For acquisition of binary signals


(potentialfree contacts resp. system
voltages switched by contacts or
transistors etc.)

In- and outputs via optocoupler

Conversion into serial signal for further


processing (i.e. by AHD-SAS 15)

Serial data transmission up to 1000m

Installation next to sensors possible


Minimized cabling demands
AHD-PS 47 / PS 30 / PS 15 Binary data station

LED Status indications

Test button for check


of short to
earth/ground
AHD-PS 47 / PS 30 / PS 15 Binary data station

Connection of binary inputs


1) Potential free contacts, Normally Open (NO) and
Normally Closed (NC).
2) Potential free contacts, Normally Open (NO) and
Normally Closed (NC), with combined common pole.
3) Transistor inputs, minus-switching, with common
minus potential. Those sensors are switched like
contacts. The minus terminal of input (N) remains
unconnected.
4) Potential free contacts, Normally Open (NO) and
Normally Closed (NC), with combined common pole
with minus potential. The minus terminal of input (N)
remains unconnected.
5) Potential free contacts, Normally Open (NO) and
Normally Closed (NC), with combined common pole
with plus potential. The input terminals (P + N) are
shorted to allow measurement of change of potential
in case of switching of contact.
6) Transistor inputs, plus-switching, with common plus
potential. The input terminals (P + N) are shorted to
allow measurement of change of potential in case of
switching of transistor.
Alarm & Monitoring Systems

Data stations
 AHD-SAS 15
 AHD-PS 47 / AHD-PS 30 / AHD-PS 15
 AHD-R 101
 AHD 882
AHD-R 101 Relay station

2 serial
inputs

15 potentialfree
change-over contacts
AHD-R 101 Relay station

Serial-Parallel-Data Conversion

Serial data transmission up to1000m


(i.e. from AHD-SAS 15)

Status-LED indications

14 relay outputs free configurable

Output No. 15 used for device failure


signaling
Alarm & Monitoring Systeme

Data stations
 AHD-SAS 15
 AHD-PS 47 / AHD-PS 30 / AHD-PS 15
 AHD-R 101
 AHD 882
AHD 882 Central unit

18 serial 16 serial
CAN
inputs outputs

5 Group relay outputs


1 Configurable alarm relay output
1 Horn relay output
1 Input for audible alarm acknowledgement
1 Input for visual alarm acknowledgement
AHD 882 Central unit

Central unit for integrated ship alarm,


display and control systems

• Microprocessor-controlled device

• Processing and distribution of data of up to 846 measuring points

• Processing of binary status data and analog limit values


with alarm, display and control management

• EngCall - Engineer call alarm


AHD 882 Central unit

Integrated alarm memory

Storage of last 10,000 messages with


date/time

Distinguishing between status and alarm


messages as well as Switch-On and
Switch-Off messages

“Memory complete” warning

If memory is filled up and a new alarm


arises, the eldest stored alarm will be
deleted and the new alarm is stored
(First-in/first-out-principle).
AHD 882 Central unit

Output for alarm and event data


RS232
Serial output for

• Alarm printer

• Laptop / PC

RS422 • LCD Display with serial input

• Voyage Data Recorder – VDR

• RS232 or RS422 selectable

Activation via DIP switch


AHD 882 Central unit

Configuration via PC Software

Configuration
via CAN-BUS-Line
Alarm & Monitoring Systems

Data converter
 AHD-UIC
 AHD-UCC
AHD-UIC Interface converter

CAN

AHD-SAS CAN bus network

3 interfaces: 1 x RS232, 2 x
RS485
Data communication with external
system
AHD-UIC Interface converter

Data acquisition from external


systems
3 interfaces for data communication
• 1 x RS232, 2 x RS485 (other variants
available)

Conversion of data protocols of external


systems
• Modbus RTU (other protocols on demand)
• Up to 100 Modbus data packages cyclically
determined
• Baud rate up to 38400 Baud
• Automatic failure detection

Integrated data processing


• Acquisition of analog and binary values
• Input data configurable as alarm or display
value
• Configuration of conversion tables
(i.e. metric/imperial)
Alarm & Monitoring Systems

Data converter
 AHD-UIC
 AHD-UCC
AHD-UCC Universal CAN converter

CAN

Data communication
with external system

CAN
AHD-SAS CAN bus network
AHD-UCC Universal CAN converter

Data acquisition from external


systems
Logging of defined data on CAN bus of
external system with data conversion to Böning
AHD-SAS CAN bus network

CAN bus interfaces galvanically isolated

Conversion of data protocols of external


systems
• NMEA 2000 ®
• SAE J1939
• Protocols of engine manufacturers
(i.e. Caterpillar, Cummins etc.)

Applicable as repeater unit with extended cable


lenghts within AHD-SAS CAN bus network
Alarm & Monitoring Systems

Displays with integrated PC, Monitors


 AHD 1019 M
 AHD 1015 TC/MTC
 AHD 919
 AHD 915 TC
AHD 1019 M Colour display

19” LED backlight LCD colour display


with integrated PC (Panel computer)

• High resolution display


(SXGA, 1280(H) x 1024(V) Pixel, 1000
cd/m2 )
• Readable even at solar radiation
• Multiple visualization pages with project-
specific resp. standard design
• Integrated PC with Pentium Mobile 1.7 GHz
processor, 1 GB RAM/1 GB flash disk
• Innovative operation concept with operation
units connected to control CAN (CAN5)
• Robust design, no moveable parts
• Automatic control of backlight illumination
• Approved for display of Radar and ECDIS
sea chart images (ECDIS push button)
AHD 1019 M Colour display

Rear view: Interfaces:


Power supply 24 V DC
(9 … 32 V DC)
5 x CAN Bus
• CAN1: Engine 1
• CAN2: Engine 2
• CAN3: AHD-SAS network
• CAN4: AHD-SAS network
(redundant)
• CAN5: Control CAN operation
1 x RS232
1 x LAN
2 x USB 2.0
Opt. In (4x Optocoupler input)
Relay Out (2x Relay output)
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
Alarm & Monitoring Systems

Displays with integrated PC, Monitors


 AHD 1019 M
 AHD 1015 TC/MTC
 AHD 919
 AHD 915 TC
AHD 1015 TC/MTC Colour display

15” LCD colour display with touchscreen


and integrated PC (Panel computer)

• High resolution display


(XGA, 1024(H) x 768(V) Pixel, 1600 cd/m 2 )
• Readable even at solar radiation
• Multiple visualization pages with project-
specific resp. standard design
• Integrated PC with Pentium Mobile 1.7 GHz
processor, 1 GB RAM/1 GB flash disk
• Operation via touchscreen or with operation
units connected to control CAN (CAN5)
• Robust design, no moveable parts
• Automatic control of backlight illumination
AHD 1015 TC/MTC Colour display

Rear view (AHD 1015 MTC): Interfaces:


Power supply 24 V DC
(9 … 32 V DC)
5 x CAN Bus
• CAN1: Engine 1
• CAN2: Engine 2
• CAN3: AHD-SAS network
• CAN4: AHD-SAS network
(redundant)
• CAN5: Control CAN operation
1 x RS232
1 x LAN
2 x USB 2.0
Opt. In (4x Optocoupler input)
Relay Out (2x Relay output)
Only with type MTC:
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
Visualisation pages (examples)

Main page Tanks


Visualisation pages (examples)

Bilges Navigation Lights


Visualisation pages (examples)

Power Engine analog


Visualisation pages (examples)

Engine digital Alarms


Visualisation pages (examples)

Events Measuring Points


Visualisation pages (examples)

Settings
Alarm & Monitoring Systems

Displays with integrated PC, Monitors


 AHD 1019 M
 AHD 1015 TC/MTC
 AHD 919
 AHD 915 TC
AHD 919 Colour monitor

19” LCD colour monitor

• High resolution display


(SXGA, 1280(H) x 1024(V) Pixel, 1000
cd/m2 )
• Readable even at solar radiation
• Approved for display of Radar and ECDIS
sea chart images (ECDIS push button)
• Video input
• Source selection by operating panels via
control CAN
• Robust design, no moveable parts
• Automatic control of backlight illumination
AHD 919 Colour monitor

Rear view (AHD 919): Interfaces:


Power supply 24 V DC
(9 … 32 V DC)
1 x CAN Bus
• Control CAN operation
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
Alarm & Monitoring Systems

Displays with integrated PC, Monitors


 AHD 1019 M
 AHD 1015 TC/MTC
 AHD 919
 AHD 915 TC
AHD 915 Colour monitor

15” LCD colour monitor with


touchscreen

• High resolution display


(XGA, 1024(H) x 768(V) Pixel, 1600 cd/m 2 )
• Readable even at solar radiation
• Display of Radar and sea chart images
• Video input
• Source selection via touchscreen or
operating panels via control CAN
• Robust design, no moveable parts
• Automatic control of backlight illumination
AHD 915 Colour monitor

Rear view (AHD 915): Interfaces:


Power supply 24 V DC
(9 … 32 V DC)
1 x CAN Bus
(Control CAN operation)
1 x RS232
Opt. In (4x Optocoupler input)
Relay Out (2x Relay output)
Touch Out
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
Alarm & Monitoring Systems

Display and Control Units


 AHD 651 Accessories
 AHD 880 TC  AHD 650 R
 Kompakt EDA 47
AHD 651 Colour display

Graphic LCD colour display


with 6.5” screen diagonal

• Transflective display for best readability even at solar radiation

• Front glass anti-reflection coated

• Degree of protection IP 67 (Front)

• Automatic dimming control of backlight illumination


AHD 651 Colour display

• Individual graphical or tabular page design

• multiple graphical presentation elements selectable


(Icons, bar graph indicator, round gauges etc.)

• Integration of images and logos on max. 17 pages


AHD 651 Colour display

Alarm page

• Integrated alarm buzzer; tabular alarm page

• Alarm indication with clear text incl. status, date and time
AHD 651 Colour display

Long time keypress

Configuration page

• Two languages selectable (Cyrillic also available)

• Switching of unit system

• Indication of CAN ID and setting of time


AHD 651 Colour display

Service page

• Indication of all monitored measuring points within the ship alarm system

• tabular form; english language

• Version information of software


Firmware / projectspec. graphic page software / projectspec. configuration softwar
AHD 651 Colour display
AHD 651 Farbdisplay
Alarm & Monitoring Systems

Display and Control Units


 AHD 651 Accessories
 AHD 880 TC  AHD 650 R
 Kompakt EDA 47
AHD 880 TC Colour display

Graphical LCD colour display


with 8.8” screen diagonal
and touchscreen

• Transflective display for best readability even at solar radiation

• Capacitive touchscreen

• Degree of protection IP 67 (Front)

• Automatic dimming control of backlight illumination


AHD 880 TC Colour display

• Individual graphical or tabular page design

• multiple graphical presentation elemente selectable


(Icons, bar graph indicator, round gauges etc.)

• Integration of images and logos on max. 17 pages


AHD 880 TC Colour display

Alarm page

• Integrated alarm buzzer; tabular alarm page

• Alarm indication with clear text incl. status, date and time
AHD 880 TC Colour display

Configuration pages

• Two languages selectable

• Switching of unit system

• Indication of CAN ID and setting of date and time

• Min/Max. brightness settings of displays adjustable


AHD 880 TC Colour display

Configuration pages

• PowerUp functionality adjustable

• Tabular presentation of all existing measuring points (current data)

• System information – version indication with clear text


AHD 880 TC Colour display

Video input

• Composite Video; BNC socket - PAL 50Hz


AHD 880 TC Colour display
AHD 880 TC Colour display
Comparison of colour displays
Alarm & Monitoring Systems

Display and Control Units


 AHD 651 Accessories
 AHD 880 TC  AHD 650 R
 Kompakt EDA 47
AHD 650 R Remote control

Remote control for colour displays

applicable for AHD 651 and AHD 880 TC

• 5 integrated operating keys for remote control of colour displays


(except power on/off function)

• Degree of protection IP 67 (Front)

• Connection via 8-pole connection cable (both endings plugable)


AHD 650 R Remote control
AHD 650 R Remote control
Alarm & Monitoring Systems

Display and Control Units


 AHD 651 Accessories
 AHD 880 TC  AHD 650 R
 Kompakt EDA 47
Kompakt EDA 47

Compact alarm and


display system

3 serial
2 serial outputs
inputs

• 48 illuminated and automatically dimmed text fields


• Unused fields shaded deep black
• Free inscription on common film negative; Block LED colours red, green, yellow
• Integrated alarm buzzer
• Configuration of EEPROM (Type 28C64) by programming device „Dataman S4"
Kompakt EDA 47
Kompakt EDA 47
Kompakt EDA 47

External operating elements required

• Audible acknowledgement (Hornquit)


• Visual acknowledgement
• Lamp test
Kompakt EDA 47

Configuration

• On- and Off-delay 1-99 sec.

• Contact type (NC/NO)

• Alarm suppression

• serial group outputs