2 Boening en SAS
2 Boening en SAS
2 Boening en SAS
Modular System
Display Display
CAN-Bus
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
Alarm & Monitoring Systems
Data converter
AHD-UIC
AHD-UCC
Alarm & Monitoring Systems
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
AHD-SAS 15 Data station
CAN
2 serial
2 serial
inputs
outputs
15 inputs
for analog and binary sensors
AHD-SAS 15 Data station
15 inputs PT100
- Resistance sensor, Measuring range -50°C … +200°C
G / 11119 x
Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors with
corresponding analog input module
AHD-SAS 15 Data station
Applicable as autarkic
alarm and monitoring system
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
AHD-PS 47 Binary data station
3 serial
outputs
47 binary inputs
AHD-PS 15 / AHD-PS 30 Binary data stations
3 serial 3 serial
outputs outputs
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
AHD-R 101 Relay station
2 serial
inputs
15 potentialfree
change-over contacts
AHD-R 101 Relay station
Serial-Parallel-Data Conversion
Status-LED indications
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
AHD 882 Central unit
18 serial 16 serial
CAN
inputs outputs
• Microprocessor-controlled device
• Alarm printer
• Laptop / PC
Configuration
via CAN-BUS-Line
Alarm & Monitoring Systems
Data converter
AHD-UIC
AHD-UCC
AHD-UIC Interface converter
CAN
3 interfaces: 1 x RS232, 2 x
RS485
Data communication with external
system
AHD-UIC Interface converter
Data converter
AHD-UIC
AHD-UCC
AHD-UCC Universal CAN converter
CAN
Data communication
with external system
CAN
AHD-SAS CAN bus network
AHD-UCC Universal CAN converter
Settings
Alarm & Monitoring Systems
Alarm page
• Alarm indication with clear text incl. status, date and time
AHD 651 Colour display
Configuration page
Service page
• Indication of all monitored measuring points within the ship alarm system
• Capacitive touchscreen
Alarm page
• Alarm indication with clear text incl. status, date and time
AHD 880 TC Colour display
Configuration pages
Configuration pages
Video input
3 serial
2 serial outputs
inputs
Configuration
• Alarm suppression