GVSESV3P

4 3

8
H1

7
DISCHARGE SUCTION

H (6 NOS)

75
35 MIN.
6
315 MIN.
1 5
C E E G.L.
20 20 30 30
D
F
B A 100
G PN25 FLANGE DETAILS
DETAIL OF FOUNDATION POCKETS
FLANGE NO OF HOLE
P.C.D THICK. OD
- 6 FOUNDATION POCKETS SIZE HOLE DIA
- 100 MM DIA. POCKET 32 100 4 18 18 140
- 6 FOUNDATION BOLTS,
40 110 4 18 18 150
M12 X 300 LONG
50 125 4 18 20 165
65 145 8 18 22 185
NO OF
PUMP MODEL VERSION SUCTION DISCHARGE A B C D E F G H H1 80 160 8 18 24 200
STAGE
100 190 8 22 26 235
eSV1 02 to 37 F,N 32 32 310 367 110 330 320 900 1040 150 565 TO 1380
125 220 8 26 28 270
eSV1 02 to 37 G 32 32 316 380 110 330 320 900 1040 150 565 TO 1380
eSV3 02 to 33 F,N 40 40 313 370 110 330 320 900 1040 150 565 TO 1310 8 1 PRESSURE GAUGE
eSV3 02 to 33 G 40 40 320 384 110 330 320 900 1040 150 565 TO 1310 7 1 PRESSURE TRANSMITTER
eSV5 02 to 33 F,N,G 50 50 326 390 110 330 320 900 1040 150 550 TO 1600
eSV10 01 to 20 F,N,G 1005 1110 155 700 TO 1525 6 1 DISCHARGE MANIFOLD
80 80 370 437 125 330 355
eSV10 21 F,N,G 80 80 370 437 125 330 400 1095 1200 155 1680 5 3 NRV VALVE
eSV15 01 to 09 F,N,G 100 100 408 505 125 330 355 1005 1110 165 735 TO 1330 4 1 SUCTION MANIFOLD
eSV15 10 TO 17 F,N,G 100 100 408 505 125 330 400 1095 1200 165 1500 TO 1850
3 6 BALL VALVE
eSV22 01 to 07 F,N,G 100 100 408 505 125 330 355 1005 1110 165 735 TO 1230
08 TO 17 F,N,G 1095 1200 165 2 3 PUMP WITH MOTOR
eSV22 100 100 408 505 125 330 400 1400 TO 1835
1 1 BASE PLATE
NOTE:-
1) SUCTION AND DISCHARGE MANIFOLD WORKING PRESSURE IS 25 KG/CM2 ITEM NO QTY DESCRIPTION
2) CUSTOMER TO PROVIDE PROPER SUPPORT FOR MANIFOLDS AT SITE TO AVOID ANY STRESS ON PIPE.
TITLE GENERAL ARRANGEMENT FOR DWG.
3) PRESSURE TANK (NOT SHOWN) TO BE MOUNTED SUITABLY AT SITE NEAR TO SYSTEM SUPPLIED.
3 PUMP SYSTEM FOR eSV SERIES NO. GVSESV3P
4) ALL LINEAR DIMENSIONS ARE SUBJECTED TO A TOLERANCE OF +/-10 MM UNLESS SPECIFIED. ALL DIMENSIONS ARE IN MM. ALL PUMP VFD( eSV1 to eSV22 SERIES)"THIS DRAWING AND THE INFORMATION DEPICTED THEREIN IS THE
5) THE DRAWING SHALL BE USED FOR REFERENCE ONLY AND SHOULD NOT BE USED PROPERTY OF XYLEM. COPIES ARE ISSUED IN STRICT CONFIDENCE AND SHALL
DWN. DATE. CKD. DATE. SCALE
FOR CONSTRUCTION PURPOSE UNLESS CERTIFIED. NOT BE REPRODUCED OR COPIED, OR USED AS THE BASIS FOR THE
MANUFACTURE OR SALE OF PRODUCTS WITHOUT PRIOR WRITTEN
6) CONTROL PANLE TO BE MOUNTED ON SEPERATE BASE. MC 22-5-14 JP 22-5-14 0.043 PERMISSION OF XYLEM".
REFER SEPERATE GA DRAWING OF CONTROL PANEL FOR WIRING DETAILS. TOLERANCES UNLESS OTHERWISE SPECIFIED:
7) HEIGHT OF PUMP (H1) VARY ACCORDING TO STAGE-MINIMUM TO MAXIMUM 00 INITIAL ISSUE 22-5-14 MC JP Applied Water Systems
X.X # X.XX # X.XXX # X.XXXX # ANGLE # FRAC. #
8) MANIFOLD MATERIAL - GALVANIZED PIPE UNLESS OTHERWISE SPECIFIED. REV.
DESCRIPTION DATE BY CKD. APP. Vadodara,India
NO. SHEET 1 OF 1