Irel - Iskra Relays

PR 15 - 16 - 17 • Contact sets with different contact configurations


Miniature relay • Single or bifurcated contacts
• Solder pins, plug-in version or PCB version
• Accessories / sockets
• The relays comply with the IEC 61810-1

Technical data

Characteristics

Type of relay PR 15-E PR 16-G PR 16-H PR 16-K PR 16-L PR 17-F PR 17-Z


PR 15-TE PR 16-TG PR 16-TH PR 16-TK PR 16-TL
Coil data at 20°C
Min. energizing to operate relay amp. turns 80 120 120 120 120 130 130
Min. energizing at which attracted
amp. turns 15 15 15 15 30 35 35
armature drops1)
Min. operating power for different
mW 100-140 210-310 210-310 210-310 220-320 290-410 290-410
windings1)
Rated power for different windings2) W 0.5 0.65 0.65 0.65 0.65 0.80 0.90
Max. operating power W 2
Energizing voltage range for different
V 0.64-110 0.6-110 0.6-110 0.6-110 0.4-110 0.75-145 0.75-145
windings
Contact data
Contact material 0.2 γm - gold coated silver
Contact version Single
Max. operating voltage V 100
Max. allowed contact current A 2
Break power3) W 30
Min. load 1 mA 100 mV
Contact resistance
mΩ 50 to 100 depending on the contact version
(measured at terminals)
General details
Max. ambient temperature °C 80 70 70 70 70 70 70
Max. allowed winding temperature °C 130
Test voltage between
Two contacts Vrms 500
Contact and core 50 Hz 500
Winding and core 500
Machanical life operations Approx. 107
Insulation resist. between
Two contacts More than 109
Contact and core Ω More than 109
Winding and core More than 109
Max. operating frequency of
operat. sec. 50
relay (min. load)
Make time, including contact msec. 13 10 10 10 10 18 18
rebounce, ar ref. voltage, approx.
Break time approx. msec. 8 8 8 8 8 15 15
Weight approx. g 20 25 25 25 25 30 30

1
Irel - Iskra Relays

Type of relay PR 15-A PR 15-B PR 15-D PR 16-C PR 15-M PR 15-P PR 16-R PR 16-S PR 16-T PR 16-U
PR 15-TA PR 15-TB PR 15-TD PR 16-TC PR 15-TP PR 16-TR PR 16-TS PR 16-TT PR 16-TU
Coil data at 20°C
Min. energizing to operate relay amp. turns 100 120 110 120 155 125 150 155 145 180
Min. energizing at which attracted
amp. turns 10 10 15 15 35 15 25 20 25 25
armature drops1)
Min. operating power for different
mW 150-210 210-310 175-250 210-310 440-620 250-360 345-490 420-570 330-460 510-730
windings1)
Rated power for different windings2) W 0.55 0.65 0.60 0.65 1.0 0.65 0.75 0.80 0.80 1.1
Max. operating power W 2
Energizing voltage range for different
V 0.5-110 0.6-110 0.55-110 0.6-110 0.92-145 0.64-110 0.78-110 0.83-110 0.77-110 0.94-110
windings
Contact data
Contact material 0.2 γm - gold coated silver
Contact version Single Double
Max. operating voltage V 220 100
Max. allowed contact current A 5 2
Break power3) W to 30V: 100 - 30V-50V: 80 - 50V-220V: 50 30
Min. load 1 mA 100 mV
Contact resistance
mΩ 50 to 100 depending on the contact version
(measured at terminals)
General details
Max. ambient temperature °C 80 70 70 70 60 60 50 50 50 40
Max. allowed winding temperature °C 130
Test voltage between
Two contacts Vrms 1000 500
Contact and core 50 Hz 1000 500
Winding and core 500 500
Machanical life operations Approx. 107
Insulation resist. between
Two contacts More than 109
Contact and core Ω More than 109
Winding and core More than 109
Max. operating frequency of
operat. sec. 50 10
relay (min. load)
Make time, including contact msec. 10 10 10 10 10 10 10 10 10 10
rebounce, ar ref. voltage, approx.
Break time approx. msec. 8 8 8 8 8 8 8 8 8 8
Weight approx. g 20 20 20 25 30 20 25 25 25 25

Umin + Umax
1) applies to min. operate voltage 2) applies to ref. voltage Uref = _________ 3) applies to the ohmic and inductance load only if the
2 contact arc is quenched

Ordering information

P R

Special information
Winding designation
Contact set version Without - plug-in types or soldering types
Terminal designation
Overall size
{ V - PCB types not in raster 2,5
T - PCB types in raster 2,5

General designation

2
Irel - Iskra Relays

Coil data at 20 °C

Type of relay PR 15
Contact set version A B D E P
Contact current 5A 5A 5A 2A 2A
Winding details Voltage operating range at 20°C

Designation Resistance No. of Min. Voltage Umin.4) (VDC) Max. Voltage


(Ω) turns Umax.4) (VDC)
00 20900±3140 32700 77 95 86 61 99 190
01 7600±1140 20700 43 53 47 34 55 110
02 3200±480 13400 29 36 32 23 37 70
03 1700±255 9900 21 26 23 16 26 50
04 890±89 7300 13.5 17 15 11 18 38
05 530±53 5800 10.5 13 11.5 8.2 13 30
06 325±33 4450 8.4 10 9.3 6.6 10.5 23
07 220±22 3700 6.8 8.5 7.5 5.3 8.7 20
08 150±15 3100 5.5 7 6.1 4.4 7.1 16
09 110±11 2700 4.6 5.6 5.1 3.7 5.8 13
10 58±5.8 1900 3.5 4.3 3.8 2.7 4.4 10
11 28±2.8 1350 2.3 3 2.6 1.8 3 7
12 18±1.8 1100 1.9 2.4 2.1 1.5 2.4 5.5
13 15±1.5 1020 1.67 2 1.85 1.3 2.1 5.2
14 9.5±0.95 840 1.26 1.6 1.4 1 1.62 4.2
15 6.8±0.68 720 1.08 1.4 1.19 0.9 1.37 3.5
16 5.1±0.51 640 0.9 1.1 0.99 0.7 1.14 3.1
17 1.5±0.15 340 0.5 0.6 0.55 0.4 0.64 1.7

Contact designation5) 1 1 2 2 2 1 21 21 21 21

Contact symbol 7 10 7 10 7
10 7 10 7 10 5 9 6 9 6
Numbers correspond 8 5
sockets designation 8 5 8 8 5 8 5

Dimensions and Terminals Layout in mm

PR 15T PR 15V

Coil terminals at the relays and sockets


Single winding coils: start 4, end 1
Double winding coils: start 3, end 2 (winding I)
start 4, end 1 (winding II)

3
Irel - Iskra Relays

Coil data at 20 °C

Type of relay PR 16
Contact set version C G H K L R S T U
Contact current 5A 2A 2A 2A 2A 2A 2A 2A 2A
Winding details Voltage operating range at 20°C

Designation Resistance No. of Min. Voltage Umin.4) (VDC) Max. Voltage


(Ω) turns Umax.4) (VDC)
00 20900±3140 32700 95 122 128 133 150 190
01 7600±1140 20700 53 68 71 66 86 110
02 3200±480 13400 36 45 48 44 56 70
03 1700±255 9900 26 32 35 32 40 50
04 890±89 7300 17 22 22 21 27 38
05 530±53 5800 13 16 17.5 16 20 30
06 325±33 4450 10 13 14 13 16 23
07 220±22 3700 8.5 10.5 11.5 10.5 13 20
08 150±15 3100 7 8.6 9.1 8.4 10.5 16
09 110±11 2700 5.6 7.2 7.6 7.0 8.9 13
10 58±5.8 1900 4.3 5.5 5.8 5.4 6.7 10
11 28±2.8 1350 3 3.7 3.8 3.5 4.6 7
12 18±1.8 1100 2.4 2.9 3.2 2.9 3.6 5.5
13 15±1.5 1020 2 2.6 2.8 2.6 3.2 5.2
14 9.5±0.95 840 1.6 2.0 2.1 1.93 2.5 4.2
15 6.8±0.68 720 1.4 1.65 1.8 1.65 2.0 3.5
16 5.1±0.51 640 1.1 1.40 1.5 1.38 1.7 3.1
17 1.5±0.15 340 0.6 0.78 0.83 0.77 0.94 1.7

1-1-1 2-2-2 2-2-1 21 - 21 1-1-1 2-2-2 2-2-1 21 - 21


Contact designation5) 21 21
1-1-1 2-2-2 2-2-1 21 - 21 1-1-1 2-2-2 2-2-1 21 - 21
16 10 16 10 16 10 16 10 16 10 16 10
Contact symbol 15 9 16 10 15 9 16 10
15 9 15 9 15 9 15 9 15 9 15 9
14 8 14 8 14 8 14 8 14 8 14 8
14 8 13 7 14 8 13 7 14 8
Numbers correspond 13 7 13 7 13 7 13 7 13 7 13 7
13 7
sockets designation 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6
11 5 11 5 11 5 11 5
11 5
11 5 11 5 11 5 11 5

Dimensions and Terminals Layout in mm

PR 16T PR 16V

Coil terminals at the relays and sockets


Single winding coils: start 4, end 1
Double winding coils: start 3, end 2 (winding I)
start 4, end 1 (winding II)

4
Irel - Iskra Relays

Coil data at 20 °C

Type of relay PR 17
Contact set version F M Z
Contact current 2A 5A 2A
Winding details Voltage operating range at 20°C

Designation Resistance No. of Min. Voltage Umin.4) (VDC) Max. Voltage


(Ω) turns Umax.4) (VDC)
70 25000±3750 34000 118 145 118 240
71 9200±1380 22000 66 81 66 145
72 3800±570 14100 43 52 43 94
73 1900±285 10400 29 35 29 66
74 1050±105 7600 21 26 21 50
75 630±63 6100 15.5 19 15.5 39
76 390±39 4650 13 20 13 31
77 270±27 3900 10.5 13 10.5 25.5
78 185±18.5 3300 8.1 10 8.1 21.5
79 130±13 2800 7.0 8.5 7.0 18
80 94±9.4 2300 6.2 7.5 6.2 15
81 70±7.0 2000 5.3 6.4 5.3 13
82 33±3.3 1400 3.5 4.3 3.5 9.0
83 22±2.2 1130 4.5 4.0 3.3 7.3
84 18±1.8 1050 2.6 3.2 2.6 6.6
85 10.5±1.05 816 1.9 2.4 1.9 5.1
86 6.6±0.66 635 1.55 1.9 1.55 4.0
87 5.4±0.54 590 1.35 1.65 1.35 3.6
88 1.75±0.18 348 0.75 0.95 0.75 2.1

21 - 21 - 21 21 - 21 1-1-1-1
Contact designation5)
21 - 21 - 21 21 - 21 1-1-1-1

22 13
21 12
Contact symbol 21 12 22 13 20 11
20 11
20 11
19 10
19 10 19 10 18 9
18 9
Numbers correspond 17 8
17 8
sockets designation 16 7
17 8 16 7
16 7
14 5
15 6 15 6
14 5
14 5

Dimensions and Terminals Layout in mm 4) The operating voltage limits U


accordance with:
min. and Umax. depend on the ambient temperature in

Umin. (t) = K1 x Umin. (20°C) Umax. (t) = K2 x Umax. (20°C)

PR 17V t
Coeff. 20°C 30°C 40°C 50°C 60°C 70°C 80°C

K1 1.0 1.05 1.09 1.13 1.17 1.215 1.255


K2 1.0 0.93 0.86 0.79 0.705 0.615 0.5

t = Ambient temperature
K1 K2 = Factors
Umin. = Min. voltage at ambient temperature t
Umax. = Max. voltage at ambient temperature t
Coil terminals at the relays and sockets Double winding coils: start 3, end 2 (winding I)
5) Where: 1 = Make contact 2 = Break contact 21 = Change-over contact
Single winding coils: start 4, end 1 start 4, end 1 (winding II)

5
Irel - Iskra Relays

Mechanical dimensions in mm Relay types


PR15
Soldering sockets
TLK 1115
Printed wiring sockets
TLK1215
Locking springs
421-505-404
(max. width of relay 19 mm) PR 16 TLK 1116 TLK 1216 421-506-434
PR17 TLK 1117 TLK 1217 421-507-256

PR 15 PR 16 PR 17

Printed Wiring Sockets

TLK 1215 TLK 1216 TLK 1217

Soldering Sockets

TLK 1115 TLK 1116 TLK 1117

Apertures for relay Sockets

Relay Fastening Springs