ISKRA RELEJI Art080 pr15 16 17 PDF
ISKRA RELEJI Art080 pr15 16 17 PDF
ISKRA RELEJI Art080 pr15 16 17 PDF
Technical data
Characteristics
1
Irel - Iskra Relays
Type of relay PR 15-A PR 15-B PR 15-D PR 16-C PR 15-M PR 15-P PR 16-R PR 16-S PR 16-T PR 16-U
PR 15-TA PR 15-TB PR 15-TD PR 16-TC PR 15-TP PR 16-TR PR 16-TS PR 16-TT PR 16-TU
Coil data at 20°C
Min. energizing to operate relay amp. turns 100 120 110 120 155 125 150 155 145 180
Min. energizing at which attracted
amp. turns 10 10 15 15 35 15 25 20 25 25
armature drops1)
Min. operating power for different
mW 150-210 210-310 175-250 210-310 440-620 250-360 345-490 420-570 330-460 510-730
windings1)
Rated power for different windings2) W 0.55 0.65 0.60 0.65 1.0 0.65 0.75 0.80 0.80 1.1
Max. operating power W 2
Energizing voltage range for different
V 0.5-110 0.6-110 0.55-110 0.6-110 0.92-145 0.64-110 0.78-110 0.83-110 0.77-110 0.94-110
windings
Contact data
Contact material 0.2 γm - gold coated silver
Contact version Single Double
Max. operating voltage V 220 100
Max. allowed contact current A 5 2
Break power3) W to 30V: 100 - 30V-50V: 80 - 50V-220V: 50 30
Min. load 1 mA 100 mV
Contact resistance
mΩ 50 to 100 depending on the contact version
(measured at terminals)
General details
Max. ambient temperature °C 80 70 70 70 60 60 50 50 50 40
Max. allowed winding temperature °C 130
Test voltage between
Two contacts Vrms 1000 500
Contact and core 50 Hz 1000 500
Winding and core 500 500
Machanical life operations Approx. 107
Insulation resist. between
Two contacts More than 109
Contact and core Ω More than 109
Winding and core More than 109
Max. operating frequency of
operat. sec. 50 10
relay (min. load)
Make time, including contact msec. 10 10 10 10 10 10 10 10 10 10
rebounce, ar ref. voltage, approx.
Break time approx. msec. 8 8 8 8 8 8 8 8 8 8
Weight approx. g 20 20 20 25 30 20 25 25 25 25
Umin + Umax
1) applies to min. operate voltage 2) applies to ref. voltage Uref = _________ 3) applies to the ohmic and inductance load only if the
2 contact arc is quenched
Ordering information
P R
Special information
Winding designation
Contact set version Without - plug-in types or soldering types
Terminal designation
Overall size
{ V - PCB types not in raster 2,5
T - PCB types in raster 2,5
General designation
2
Irel - Iskra Relays
Coil data at 20 °C
Type of relay PR 15
Contact set version A B D E P
Contact current 5A 5A 5A 2A 2A
Winding details Voltage operating range at 20°C
Contact designation5) 1 1 2 2 2 1 21 21 21 21
Contact symbol 7 10 7 10 7
10 7 10 7 10 5 9 6 9 6
Numbers correspond 8 5
sockets designation 8 5 8 8 5 8 5
PR 15T PR 15V
3
Irel - Iskra Relays
Coil data at 20 °C
Type of relay PR 16
Contact set version C G H K L R S T U
Contact current 5A 2A 2A 2A 2A 2A 2A 2A 2A
Winding details Voltage operating range at 20°C
PR 16T PR 16V
4
Irel - Iskra Relays
Coil data at 20 °C
Type of relay PR 17
Contact set version F M Z
Contact current 2A 5A 2A
Winding details Voltage operating range at 20°C
21 - 21 - 21 21 - 21 1-1-1-1
Contact designation5)
21 - 21 - 21 21 - 21 1-1-1-1
22 13
21 12
Contact symbol 21 12 22 13 20 11
20 11
20 11
19 10
19 10 19 10 18 9
18 9
Numbers correspond 17 8
17 8
sockets designation 16 7
17 8 16 7
16 7
14 5
15 6 15 6
14 5
14 5
PR 17V t
Coeff. 20°C 30°C 40°C 50°C 60°C 70°C 80°C
t = Ambient temperature
K1 K2 = Factors
Umin. = Min. voltage at ambient temperature t
Umax. = Max. voltage at ambient temperature t
Coil terminals at the relays and sockets Double winding coils: start 3, end 2 (winding I)
5) Where: 1 = Make contact 2 = Break contact 21 = Change-over contact
Single winding coils: start 4, end 1 start 4, end 1 (winding II)
5
Irel - Iskra Relays
PR 15 PR 16 PR 17
Soldering Sockets