Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MRS3000D V/Uhf Wide Band Receiver

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

MRS3000D

V/UHF WIDE BAND RECEIVER


♦ Frequency Range 20 to 3000 MHz
n
♦ 10 MHz Instantaneous Bandwidth
♦ 30 GHz/s Scan Speed
Key Features The "MRS" Advantage:
• Frequency range 20 - 3000 MHz Meeting the challenge of the modern
frequency agile and time-varying signals
• Instantaneous bandwidth 10MHz
scenario, the MRCM® MRS wideband
• Scanning speed up to 30 GHz/s receiver series utilises the latest technology to
• Instantaneous Frequency, Amplitude and achieve outstanding scanning performance and
Time activity waterfall display high detection sensitivity.

• Selectable Detection Algorithms High dynamic range circuitry, Digital Signal


Processing and sophisticated man-machine
• Zoom functions for Frequency domain interface graphics combine in a cutting edge
analysis
solution to modern V/UHF ESM
• Slaved (optional) narrowband receiver for requirements.
immediate demodulation
• Recording of Spectral Activity to disk Expansion Options
• Built-in Fixed Frequency, Frequency
Hopping and Burst detection modes with • Monitoring receiver, with handoff
definable duration limits • Digital audio recorder – using hard disk/s
• Detection of V/UHF frequency hopping • Integrated GPS
transmissions up to 500 hops/second • Additional operator workstations
• Peak select facility
• State-of-the-art detection sensitivity
Applications
• Multi-level BITE • Spectrum Surveillance to identify new
transmissions anywhere in the 20 MHz to
• AC or DC power options
3000 MHz range
• Software components designed for stand- • Stand-alone or integrated in system
alone use and easy system integration • Search Task to locate frequencies of
with: known transmissions that changed
¾ TCP/IP based Application Interfaces operating frequency
• Band scanning to identify new activity in
¾ Manual and Automatic Tasking and
a specific band
Process Flow
• Scanning receiver for tasking handoff
¾ User Interface support for Spectrum receivers in a system
Recording and Playback • Front end for jamming systems
¾ Pool management of valuable • Frequency monitoring and management
resources systems
¾ Switch-On-Stand-Alone Functionality • Search Task with slaved narrowband DF
equipment
¾ Simultaneous Multi-Client • Comprehensive functionality, flexibility,
Application Support and compact dimensions ease integration
¾ Fault tolerant interface management into any system, platform or environment
General Hardware Description
The MRS3000D wideband receiver consists of
an RF front end for block down-conversion of
the received spectrum connected to a Digital
Signal Processor in a computer workstation.

The RF signal at the antenna is routed to the


wide band front end. The Intermediate
Frequency (IF) signal is sampled and
processed by the Digital Signal Processing
equipment, which includes calculating real-
time Fast Fourier Transforms (FFT). Wideband and zoomed waterfalls with amplitude
spectra and control panel dialogs, simultaneous VHF
hopper signals shown.
The detection algorithm is performed in real
time on the DSP processors. The operator may set the scanning limits in the
wideband controls, adjust the gain settings or
The FFT data is displayed on the Computer select automatic gain control.
Workstation using user-friendly software that Once a signal of interest is located, the
runs under the Windows® operating system. operator can drag the position of the
instantaneous window to that of the signal of
A narrow band receiver can be slaved to the
interest. The display can be frozen and time
frequency cursor, being tuned to the frequency
and frequency domain measurements, such as
of interest when the operator clicks on the
bandwidth and dwell time can be made using
signal. This allows fast selection of newly
selectable cursors.
acquired signals and ensures that intercepts are
performed on signals of real interest. Filters may be set to automatically trigger on
signals with a specified duration thus allowing
With MRCM Intelligence Flow System event triggering.
software, seamless interfacing to Direction Frequencies and sub-bands can be specified in
Finding equipment is possible. This gives a a list and blocked from the display in order to
Line-of-Bearing indication on a polar display, avoid detection reporting on known channels.
slaved to the frequency cursor.

User Interfaces
The user interface software runs under the
Windows® operating system on a computer
workstation. The typical displays show the
instantaneous (zoom) window with a time-
waterfall display as well as a wide band
scanning window with a similar time-waterfall
display.

Searching for signals in a dense signal environment


Specification Summary
Parameter MRS3000D
Frequency Range 20 to 3000 MHz
Instantaneous Bandwidth 10 MHz with 12.5 kHz resolution.
Effective Scan Speed 30 GHz/s (25 kHz resolution)
Scan/Zoom Frame Bandwidth 10MHz 10MHz 5MHz 2.5MHz 1MHz
Corresponding Resolution Bandwidth 25kHz 12.5kHz 6.25kHz 3.125kHz 1.25kHz
Selectable Scanning Frequency Range Multiples of Frame Bandwidth
Sensitivity (10dB SNR) ≤ -110 dBm @ 12.5kHz RBW
≤ -130 dBm @ 1.25kHz RBW*
IF and Image Rejection > 80 dB
A/D Spurious Free Dynamic Range ≥ 75 dB
Analogue IF Bandwidths 10 MHz and 1.2 MHz
Gain Control AGC or MGC, in the range -8 to +52dB
Frequency Reference Input/Output 10 MHz
Control Interface: RF High Speed Synchronous Serial, RS232C
User Interface Windows® XP, XGA ≥ 1280 x 1024
Power Supply 110/240 VAC 50-400Hz or
24 VDC nominal (19 – 30 VDC)
Weight RF Front End Unit 10 kg
DSP/PC Unit 16 kg
Dimensions RF Front End Unit ½ 19” x 3U x 500mm
DSP/PC Unit 19” x 4U x 555mm
Operating Temperature -10°C to +55°C
Storage Temperature -30°C to +70°C
* With advanced sampling and integration.

Products for Monitoring, Reconnaissance


and Counter Measures provided by
Version 0.00 24 January 2007
GMA-300-123-SG

Visit our homepage: http://www.mrcm.net