Data Sheet: PART NO. 632 858
Data Sheet: PART NO. 632 858
Data Sheet: PART NO. 632 858
§ Provides an output that can be used to stop the lift safely during a car-top intrusion
or machine room intrusion (optional)
§ Greatly reduces the risk of accidents
§ Designed for new and existing lifts
§ Deters intruders
§ Quick and easy to fit to any type of lift
§ Cost effective solution
INTRODUCTION
The Surfguard has been developed as a safety system
to detect intruders on the top of a lift car. On detection
of an intruder, the unit provides an output that can be
used to stop the lift running. In addition, outputs are
provided to operate a beacon and siren. An auxiliary
output is also available for remote alarm indication.
2-core 2m cable, so it can be fitted separately from easy wiring installation. The beacon and thesiren can
the control unit. The control unit is mounted on the be installed on the car top, or at the top of the lift
car top, or in a remote location, such as the machine shaft.
MEMCO LTD, CLYDE HOUSE, REFORM ROAD, MAIDENHEAD, BERKSHIRE, SL6 8BY, UK. Tel +44 (0)1628 770734 Fax +44 (0)1628 621947 www.memco.co.uk
CONTROLLER CONNECTIONS (see Fig 3)
n Input DUAL DETECTION
DEVICE
Four different inputs are available, two of which are
used to monitor the dual detection device and the VERTICAL SENSOR
vertical sensor. Each detector head is connected by
a 2.7m cable with 3 cores plus a screen. Each core
is terminated using boot-lace ferrules. The cores carry
+12V DC, 0V, and the trigger output (PNP-N/C).
n Output
Three different relays are programmed to operate a
number of devices after a detection:
§ The main trigger relay is connected to the lift FIXING
controller, and is used to stop the lift BRACKET
immediately and safely.
§ A dual pole relay is used to trigger the beacon
and the auxiliary output (providing, for example,
information to a remote control centre). The red
beacon uses the 12V DC supplied by the ADJUSTABLE
controller. Its nominal power is 3W and it is STAND
fully protected to IP65.
§ The siren relay is used to trigger the siren. The
sound output of the supplied siren is 85dbm.
This peripheral device also uses the 12V DC
supplied by the Surfguard controller. An
adjustable cut-off timer, pre-settable from 45
secs to 5 minutes, is available in the controller.
ON SITE ADJUSTMENT
The Surfguard system alarm characteristics can be
configured on site to suit local conditions, using the
4 system delay potentiometers. FIXING HOLES
STAND BASE
§ Arming Delay
The arming delay of 5sec-50sec allows the lift
engineer to arm the system through the Fig 2: Surfguard dual detection device on adjustable stand
controller key switch positioned on the car top.
The delay allows him to leave the protected
area, without triggering the Surfguard during the § Alarm Delay (Machine Room Door)
delay period. The machine room door switch delay of 1sec-
45sec allows the lift engineer to arm or disarm
§ Alarm Delay (infra-red system) the system through the controller key switch,
The alarm delay of 1sec-45sec allows the lift when the controller is positioned in the machine
engineer to disarm the system, via the controller room, without triggering the Surfguard system.
key switch, without activating the peripheral
devices. § Siren Timeout
The siren timeout gives a time delay of between
45sec-5min before the siren is muted. This
delay allows the siren to be deactivated but
the beacon to carry on flashing, after an alarm
has occurred.