Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032

Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011


Contract Number: A5MU Page 1 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

This specification has been revised as indicated below and described in the revision record on the
following page. Please destroy all previous revisions.

Revision Date Originator's Reviewed/Checked By Pages


No. Name & Initials Name & Initials
A 7/13/10 L. STREEB T. WOOD ALL
0 10/15/10 L. STREEB T. WOOD ALL
1 3/1/11 L. STREEB T. WOOD ALL

APPROVALS SIGNATURES DATE

Lead Engineer
ENGINEERING
MANAGER:
Client Approval:

ISSUED FOR : Construction X Other ISSUED APPROVED


Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 2 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

Record of Revisions
Revision Date Description
No.

A 7/13/10 CLIENT REVIEW - TOC

0 10/15/10 ISSUED FOR REVIEW/APPROVAL - SPECIFICATION

1 3/1/11 ISSUED APPROVED


Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 3 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

TABLE OF CONTENTS

1.0 SCOPE.................................................................................................................................................... 4

2.0 APPLICABLE CODES, STANDARDS AND REFERENCES ................................................................ 4


2.1 AGMA (American Gear Manufacturers Association)............................................................ 4
2.2 AMCA (Air Movement and Conditioning Association)......................................................... 4
2.3 ANSI (American National Standards Institute)...................................................................... 4
2.4 ASA (Acoustical Society of America) .................................................................................... 4
2.5 HI (Hydraulic Institute)............................................................................................................. 5
2.6 IEEE (Institute of Electrical and Electronics Engineers)...................................................... 5
2.7 ISO (International Standards Organization) .......................................................................... 5
2.8 NEMA (National Electrical Manufacturers Association) ...................................................... 5
2.9 NMTBA (National Machine Tools Builder's Association) .................................................... 5
2.10 CSA (Canadian Standards Association).............................................................................. 5
2.11 OSHA (Occupational Safety and Health Administration).................................................. 5
2.12 RCA (Royal Commission Standards)................................................................................... 5
3.0 SUPPLIED BY CONTRACTOR OR SUPPLIER .................................................................................... 6

4.0 DEFINITIONS ......................................................................................................................................... 6

5.0 OVERALL REQUIREMENTS................................................................................................................. 7

6.0 DOCUMENTATION ................................................................................................................................ 8

7.0 REQUIREMENTS ................................................................................................................................... 9


7.1 General...................................................................................................................................... 9
7.2 Instrumentation and Measurement Technique ..................................................................... 9
7.3 Noise Measurement Locations ............................................................................................. 10
8.0 INSPECTION AND TESTS................................................................................................................... 12

APPENDIX A - EQUIPMENT NOISE LEVEL - SAMPLE FINAL NOISE TEST ........................................ 13


Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 4 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

1.0 SCOPE

This specification defines the permissible noise levels for equipment; defines noise measurement
procedures including required noise measurement locations; and defines information that must be
supplied with the proposal.

This specification stipulates the requirements for Supplier's equipment that will provide a low
noise environment. This specification identifies equipment noise level limitations, noise testing
requirements, and noise data documentation requirements. These limitations and requirements
apply to equipment that generates noise in the speech and hearing range and to stationary and
mobile equipment and machinery that may produce continuous, intermittent, or impulsive noise.

2.0 APPLICABLE CODES, STANDARDS AND REFERENCES

2.1 AGMA (American Gear Manufacturers Association)

6025-D98 Sound for Enclosed Helical, Herringbone and Spiral Bevel Gear Drives

2.2 AMCA (Air Movement and Conditioning Association)

Standard 300-08 Reverberant Room Method for Sound Testing of Fans

2.3 ANSI (American National Standards Institute)

S1.2 Method for Physical Measurement of Sound

S1.36 Method for the Determination of Sound Power Levels of Noise Sources

2.4 ASA (Acoustical Society of America)

S1.1 Acoustical Terminology

S1.11 Specification for Octave Band and Fractional-Octave-Band Analog and Digital
Filters

S1.13 Measurement of Sound Pressure Levels in Air

S1.4 Specification for Sound Level Meters

S12.1 Guidelines for Preparation of Standard Procedures to Determine the Noise


Emission from Sources

S12.3 Statistical Methods for Determining and Verifying Stated Noise Emission Values
of Machinery and Equipment
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 5 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

S12.16 Guidelines for the Specification of Noise of new Machinery

2.5 HI (Hydraulic Institute)

HI 9.4 Measurement of Airborne Sound

2.6 IEEE (Institute of Electrical and Electronics Engineers)

C85 Test Procedure for Airborne Sound Measurements on Rotating Electric


Machinery

2.7 ISO (International Standards Organization)

ISO 2151 Acoustics – Noise test code for compressors and vacuum pumps,
Engineering Method (Grade 2)

2.8 NEMA (National Electrical Manufacturers Association)

NEMA TR-1 Transformer, Regulators and Reactors (Section 9.04)

2.9 NMTBA (National Machine Tools Builder's Association)

NMTBA Noise Measurement Techniques

2.10 CSA (Canadian Standards Association)

CSA Z107.56 Procedures for the measurement of Occupational Noise Exposure

2.11 OSHA (Occupational Safety and Health Administration)

29CFR1910 Occupational Safety and Health Standards

29CFR1926 Safety and Health Regulations for Construction

Noise Control, A Guide for Workers and Employers

2.12 RCA (Royal Commission Standards)

Section 15070 Mechanical Sound, Vibration and Seismic Control


Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 6 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

3.0 SUPPLIED BY CONTRACTOR OR SUPPLIER

3.1 Supplier shall conform to all requirements of this specification, unless otherwise
specifically agreed to in writing by Purchaser.

3.2 This specification requires compliance with Purchaser noise level limitations and
applicable federal, state, county, and local laws and regulations.

3.3 Supplier shall state in writing any exceptions to the requirements of this specification.

3.4 Supplier shall contact Purchaser for resolution regarding any interpretation of this
specification or conflict between this specification and other Purchaser specifications
before proceeding with any work.

3.5 The noise measurement techniques, instrumentation, and test conditions utilized to
acquire noise level data that is reported according to this specification for all equipment
shall comply with the measurement procedures contained in this specification.

3.6 Supplier shall submit all available sound pressure level and sound power level data with
the proposal, as requested on the datasheets, to qualify for bid evaluation.

3.7 When mufflers, silencers, mutes, diffusers, and other similar equipment are proposed,
their inherent self noise shall be taken into account in their design with special attention
given to casing radiation to ensure that the regenerated noise does not exceed the
allowable sound pressure level.

3.8 Final test noise measurements shall be made on the purchased equipment by Supplier
and test data made available to Purchaser prior to shipment. Test data shall be provided
on Appendix A form. Purchaser reserves the right to send qualified representatives to
Supplier's plant and Component Supplier's plant to observe or assist in the noise tests.
Suppliers shall notify Purchaser at least 10 days in advance of such tests.

4.0 DEFINITIONS

4.1 dBA: Sound pressure level in decibels (reference 20 by 10:(-6:) newtons per square
meter) as read on a sound level meter set to the A weighted network, slow response
setting.

4.2 A-Weighted: A-Weighted means a specific weighting of the sound pressure level for the
purpose of determining the human response to sound. The specific weighting
characteristics and tolerances are those given in ASA S1.4.

4.3 Equipment Train: A system, supplied or packaged by Supplier, comprised of a driver, all
driven equipment including gears and couplings, and all auxiliary equipment.

4.4 PWL (Sound Power Level): Expressed in decibels (reference 10:(-12:) watts).
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 7 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

4.5 SPL (Sound Pressure Level): Expressed in decibels (reference 20 by 10:(-6:) newtons
per square meter).

4.6 Sound Attenuation: The reduction of sound by various means.

5.0 OVERALL REQUIREMENTS

5.1 Purchaser's objective is to procure equipment that will not exceed a noise level of 85 dBA
at a distance of 1 m. Additionally, Purchaser shall evaluate other noise limits proposed
by Supplier provided the requirements of this specification are satisfied.

5.2 Noise from equipment trains includes the total combined noise from driver, driven
equipment including any gears and couplings, and auxiliary equipment, supplied, but not
necessarily manufactured by Supplier. Individual equipment items in an equipment train
supplied by Supplier need not be limited to 85 dBA provided that the complete equipment
train does not exceed 85 dBA when measured in accordance with this specification. The
output of the various noise sources shall be added using the logarithmic sum method.
Noise limits apply at all operating points within the equipment's' normal performance
range. Suppliers shall include an alternative quotation to attain the 85 dBA noise levels.

5.3 Octave-band sound pressure limits in dB for the 85 dBA sound pressure levels (at 1 m
distance) established in this specification shall generally be as follows:

Sound Pressure Limits

OCTAVE BAND FREQUENCIES, HZ dBA

31.5 63 125 250 500 1000 2000 4000 8000

dB 106 102 95 90 85 82 81 81 83 90

dB 101 97 90 85 80 77 76 76 78 85

NOTE: the 90 dBA octave band SPL limits are provided as a reference only.
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 8 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

5.4 The sound pressure level (SPL) must be given in each of the octave band frequencies
shown in 5.3 for his equipment, and the overall sound levels in dBA, illustrating it meets
the 85 dBA requirement.

5.5 Impulsive or impact noise shall not exceed 140 dB peak sound pressure level at the
measurement locations listed in this specification.

5.6 Emergency services, including, but not limited to safety relief valves, alarms, and fire
water pumps, are excluded from meeting any noise limit defined in this specification
when operating outdoors.

6.0 DOCUMENTATION

6.1 Supplier shall state noise guarantees for each component of each equipment train or for
each equipment train as a whole on the Equipment Noise Level Data Sheet.

A. Supplier shall complete the Equipment Noise Level Data Sheet for the following
conditions as applicable:

a. Supplier's standard design

b. If Supplier's standard design exceeds the specified noise limit of 85 dBA at 1


m, noise data for a design that meets the 85 dBA limit, or that meets another
noise limit as agreed upon under the conditions of this specification shall be
supplied. A description of the acoustic treatment required and the additional
cost, if any, shall be included with this data. Acoustic treatment shall not limit
equipment operation or accessibility nor shall they create safety or fire
hazards.

B. Octave-band data and supporting calculations or measurement data shall be


included with the proposal as required by the Equipment Noise Level Data Sheet.

C. If Supplier furnishes sound levels measured in accordance with an accepted


industry standard or practice that does not include important sound sources
normally associated with the equipment (for example, intake and exhaust noise
of engines, and separately supplied auxiliary equipment), then omitted sound
sources shall be determined and reported as separate items.
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 9 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

6.2 Control valve Suppliers shall utilize standard calculation or measurement procedures for
determining control valve noise.

6.3 Equipment shall be guaranteed to meet the noise limits specified in this specification,
unless other limits are agreed upon and included in the Purchase Order. Guarantee shall
be included in Supplier's quotation and on Equipment Noise Level Data Sheet.

7.0 REQUIREMENTS

7.1 General

A. The minimum allowable free SPL (field sound pressure) level shall be according
to the datasheet and measured at 1 m from the major boundary surfaces of the
equipment operating at rated load. If sound PWL (power levels) are supplied, the
calculated free field SPL at 1 m shall not exceed the limit on the datasheet
including the directivity effect. Additionally, the noise level at an operator's
station on Supplier's equipment, regardless of source, shall not exceed the limits
on the datasheets.

B. Proposal shall be the supplier's best offer of untreated equipment that meets the
Datasheet requirement. In addition, the supplier is encouraged to submit
equipment designs that provide for optimal noise reduction. If the untreated
equipment exceeds the level on the Datasheets, the supplier shall propose
equipment employing integral noise reduction treatments that meet the
requirement.

C. Supplier shall guarantee that the equipment noise levels measured at Supplier's
facility prior to shipment do not exceed the allowable SPL limit as specified on
the datasheets. Supplier shall guarantee that the sum of noise sources for
equipment supplied within the supplier's package shall not exceed the specified
limit, including equipment that Supplier may purchase and install on the supplier's
package (such as motors, gearboxes, hydraulic devices, blowers, fans, and
pneumatic and electrical devices).

D. Sound pressure measurement procedures shall be guided by the provisions of


ANSI S1.2, Method of Physical Measurement of Sound, or equivalent, except
where other test codes are specified. Sound measuring equipment shall meet
the requirements of ASA S1.4, Type 1 sound level meter; CSA Z107.56 and ASA
S1.11 octave-band filters Class II.

7.2 Instrumentation and Measurement Technique

A. Instruments used to measure noise levels shall meet ASA S1.4, Type I, and ASA
S1.11, Class II, or latest revision.
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 10 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

B. Instruments shall be calibrated as recommended by the instrument manufacturer


and calibration shall be made before and after the test of each piece of noise
producing equipment. The calibrating instruments shall be certified by the
manufacturer or a licensed instrument calibrator within a year of the test, and the
records shall be made available for review by Purchaser upon request.

C. SPL reported by Supplier shall be referenced to 20 micro Pascal.

7.3 Noise Measurement Locations

A. The basic noise measurement locations for individual equipment and equipment
trains are listed below. Any deviation in measurement location shall be clearly
identified and described on the Equipment Noise Level Data Sheet.

a. Air Cooled Heat Exchangers:

Measurements shall be made at the following positions:


1. 1.5 m above grade and horizontal distance of 1 m outside the periphery
of the coolers. At least 4 random points around the coolers shall be
used.

2. Where header access platforms are furnished 1.5 m above the platform
at positions a worker would ordinarily be standing or walking.

b. Compressor-Driver Trains: Measurements shall be in accordance with the


general provisions of the ISO 2151.

c. Pump-Driver Trains: Measured at a horizontal distance of 1 m from nearest


major equipment surface at an elevation of 1.5 m from the equipment base.

d. Fired Heaters, Incinerators, and Boilers: Measured at a horizontal distance


of 1 m from the plane of the furnace wall, or 1 m from the burners in the case
of wall mounted burners, with all burners firing at rated capacity. If noise
suppression is required to meet this specification, Supplier shall supply the
following noise suppression items:

1. Quiet type gas orifices for burners using primary air inspiration

2. Acoustically lined plena (e.g. Enclosures)

3. Primary air mutes

Supplier shall note in the proposal if these are being provided.


Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 11 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

e. Motors and Generators: Measured at a distance of 1 m from the nearest


major surface of the equipment and at a height of 1.5 m above the base of
the equipment.

f. Ground Flares: Operating at 100 percent of rated flow measured at a


horizontal distance of 6 m from the base of the flare wall and at an elevation
of 1.5 m above grade.

g. Ejectors: Measurements for exhaust and case noise shall be made at the
following locations:

1. Exhaust measured at a distance of 1 m from the point of exhaust to the


atmosphere, perpendicular to the direction of flow of the exhaust.
2. Case measured at a distance of 1 m from the ejector body.
h. Exhaust Heads and Vents (including startup and intermittent service):
Measured at a distance of 1 m from the point of exhaust from the discharge
to the atmosphere, perpendicular to the direction of flow of the exhaust. (For
emergency service, refer to Section 5.4., of this specification.)

i. Control Valves: Operating at design conditions (with upstream and


downstream pipe schedule as indicated on the control valve datasheet),
measured 1 m downstream of the valve and at a distance of 1 m from the
pipe.

j. Control Valve Manifold Piping, General Piping: Measured at a horizontal


distance of 1 m from the pipe surface.

k. Induced and Forced Draft Fans and Blowers: Measured at a distance of 1 m


from the casing and the inlet duct, 1.5 m above the equipment base.

l. Diesel Engines, Gas Engines: Measured at a distance of 1 m from casing.


Measurements should also be taken 1 m from any intake or exhaust duct or
opening.

m. Steam Turbines: Measured at a distance of 1 m from casing, 1.5 m above


grade or platform. Measurements should also be made at a distance of 1 m
from inlet and exhaust piping or ducting.

n. Elevated Flares: Operating at 100 percent of rated flow measured at a


horizontal distance from the base of the flare stack equal to the radius of the
thermal radiation safety circle.

o. Cooling Tower: Measured at any location 1.5 m above the fan deck and also
at 1 m from edge of basin at an elevation of 1.5 m.
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 12 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

p. Mechanical Agitators (including Driver): Measured at a horizontal distance of


1 m from the agitator (outside of any associated vessel) at a height of 1.5 m
from grade.

q. Gas Turbines: Measured at a distance of 1 m from casing, 1.5 m above


grade or platform. Measurements should also be made at a distance of 1 m
from air intake and exhaust ducts and 1 m from intake and exhaust openings
perpendicular to the direction of flow. If intake exhaust silencers are
supplied, measurements should be made at a distance of 3 m from outlet
perpendicular to the direction of flow.

r. Miscellaneous Equipment (equipment not covered by the sections above):


Measured at a horizontal distance of 1 m from the nearest major surface of
the equipment and at a height of 1.5 m above the base of the equipment.

B. If an acoustical enclosure or other noise reduction treatment is supplied by


Supplier, the guaranteed noise levels must be met at a distance of 1 m from any
surfaces of the enclosure or treatment.

8.0 INSPECTION AND TESTS

8.1 If specified in the purchase order, noise test may be witnessed by Purchaser and
designated representatives. Supplier shall provide notification at least 10 days in
advance of these tests.

8.2 If sound level tests are run in an environment not covered in ANSI S1.2 or ISO 2151,
procedures for calculating or correcting the data supplied in the Equipment Noise Level
Data Sheet shall be included in Supplier's proposal.

8.3 Final noise test data shall be recorded on SAMPLE FINAL NOISE TEST form (Appendix
A) and related information on the datasheet completed.

8.4 Supplier shall specify the operating conditions of the equipment for the data acquisition
for SAMPLE FINAL NOISE TEST form (Appendix A). If other than the operating and
rating points of the equipment datasheets, those points shall be extrapolated and
guaranteed to the operating and rated points of the proposed equipment. The method
and source of the method of extrapolating shall be stated.

8.5 If the equipment cannot be run at the operating or rating points for the SAMPLE FINAL
NOISE TEST form (Appendix A) the exact operating conditions for the test shall be
described and shall be submitted to Purchaser for written approval. The written approval
must be obtained 10 days prior to running the test.

8.6 Supplier shall provide a sketch of the test location including room dimensions, noise
source location, microphone locations, and operator location.
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 13 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

APPENDIX A
EQUIPMENT NOISE LEVEL
SAMPLE FINAL NOISE TEST

The Supplier is to provide a sketch of noise source location and dimensions, microphone location,
operator location, and dimensions of the test room and surface description.

EQUIPMENT TESTED

Manufacturer
Model No.:
:
Operating Conditions: RPM BHP Capacity: Pressure:
Type of Noise:  Continuous  Intermittent  Impact
Discrete
Tones:

INSTRUMENTATION USED IN TEST

Sound Level Meter: Manufacturer Model No.


Microphone: Manufacturer Model No.
Octave Band Filter: Manufacturer Model No.
Calibrator: Manufacturer Model No.
Date of Last Manufacturer’s Calibration: Microphone
Octave Band
Filter
Sound Level
Meter
Calibrator
Ambient Test Conditions: Temperature Relative Humidity %
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 14 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

APPENDIX A
EQUIPMENT NOISE LEVEL
SAMPLE FINAL NOISE TEST

RESULTS RECORDED DURING TEST:


Microphone Location Octave Band Center Frequencies (Hz)
dBA dB 31.5 63 125 250 500 1000 2000 4000 8000
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4032
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 01 Mar 2011
Contract Number: A5MU Page 15 of 15
Revision 1

SPECIFICATION - SOUND CONTROL OF MECHANICAL EQUIPMENT – NON-API

APPENDIX A
EQUIPMENT NOISE LEVEL
SAMPLE FINAL NOISE TEST

SKETCH OF TEST EQUIPMENT AND NOISE LEVEL MEASURING POSITION(S) :

CERTIFICATION BY CONTRACTOR:
Contractor has performed the Noise Test in accordance with Specification MQ-SP-M-4032, Sound
Control of Mechanical Equipment – Non-API.

Contractor Name (above)

Signature (above) Title Date

APPROVAL BY MARAFIQ:

Approved  Not Approved 

Signature (above) Title Date