MQ SP M 4017 PDF
MQ SP M 4017 PDF
MQ SP M 4017 PDF
This specification has been revised as indicated below and described in the revision record on the following
page. Please destroy all previous revisions.
Lead Engineer
Engineering Manager:
Client Approval:
Record of Revisions
Revision Date Description
No.
TABLE OF CONTENTS
FOREWORD ...............................................................................................................................................................4
FOREWORD
This specification is intended to supplement Process Industry Practice PIP resp003V-2010 Specification
for High Power Vertical Centrifugal Pumps for Water Service, which is part of this specification.
Numbering of the following sections and paragraphs corresponds to section and paragraph numbering of
Process Industry Practice PIP RESP003V-2010.
Paragraphs shall be highlighted as shown below to indicate the type of change from the PIP Practice.
(Decision) A decision has been made as required. If no decision has been made by this
specification, refer to the corresponding data sheet.
(Mod) Clarification or rewording has been made to the corresponding paragraph, but not a
substitution invalidating the paragraph.
Note: Requirements of PIP RESP003V-2010 that are not revised remain applicable.
Note: References shall mean those in effect at the time of contract award.
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4017
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 08 Mar 2011
Contract Number: A5MU Page 5 of 7
Revision 1
1.0 INTRODUCTION
1.2 Scope
This specification supplements the datasheets on which the operating conditions and
special requirements are listed in detail for each individual pump. Whenever the data
included on the individual datasheets conflict with this specification, Supplier shall resolve
conflicts with Purchaser.
Compliance with this specification does not relieve Supplier of the responsibility of
furnishing pumps and accessories of proper design, mechanically suited to meet
operating guarantees at the specified service conditions. Nor does it relieve Pump
Supplier of the responsibility of furnishing equipment assembled and prepared for
shipment in a professional manner.
Suppliers qualified by experience manufacturing the proposed units shall supply pumps.
To qualify, the Supplier shall have manufactured at least two (2) pumps of comparable
size, model, power rating, and speed in similar service as indicated in the individual
specification and data sheets. These pumps shall have completed at least 8000 hours of
continuous operation satisfactorily.
1.6.1 Supplier’s quotation shall conform to this Specification and any addenda. At the
Supplier’s option, an alternate quotation may be offered if the following two
conditions are met:
The pumps supplied to this standard shall have ISO dimensions and comply with
comparable ISO standards.
The supplier shall assume unit responsibility for all equipment and all auxiliary systems
included in the scope of the order.
4.0 REQUIREMENTS
(Mod) Solid Hubs on impellers are required. An impeller made from a cored hub
requires consent of Buyer.
4.2.1 Drivers
Power and Water Utility Company for Jubail and Yanbu (MARAFIQ) Specification MQ-SP-M-4017
Project Name: MARAFIQ SPEC DEVELOPMENT Date: 08 Mar 2011
Contract Number: A5MU Page 7 of 7
Revision 1
Pumps shall have a separate soleplate for bolting and grouting to the
foundation. Soleplate shall be machined on its top surface and shall
have at least four vertical leveling screws.
4.4.2 The Purchaser requires ten working days notice prior to scheduled test
or inspection.
4.4.3 For Vertical Pumps over 4.5 meters (14.7 ft) in length, a fit up check is
required.
End of Specification