Mototrbo Phone Patch Interface Notes: TM TM
Mototrbo Phone Patch Interface Notes: TM TM
Mototrbo Phone Patch Interface Notes: TM TM
This document is a guide for interfacing a Zetron Model 30 Worldpatch (L3284) with a MOTOTRBOTM Radio System.
The Phone Patch should be collocated with and interfaced directly to the MOTOTRBOTM XPR 8400 repeater. Please
refer to the Operators Manual provided with the Phone Patch for detailed information and troubleshooting. The
instructions in this document are for the non-SelCall version of the Zetron Model 30; other Phone Patch models may
require different settings. If you have further questions, please contact the Motorola Project Manager or System Engineer
for your site.
• Zetron Model 30 World Patch (SelCall and non-SelCall models available). Configuration is different depending
on Phone Patch model.
• Repeater to Phone Patch Interface Cable. Assembly required, see instructions below.
• Digital Telephone Interconnect Upgrade Entitlement ID (HKVN4049). Software license provided by Motorola.
• (Optional) 19” Rack Mount Panel (TT04061AA). Allows Phone Patch to be mounted to cabinet rails.
• A cable must be constructed to interface P1 on the Zetron Model 30 to the Repeater Rear Accessory Connector.
Repeater Configuration:
• The Repeater codeplugs will be provided with the hardware interfaces and settings already configured.
1
o General Settings: Analog Mic AGC: Unchecked
o Channels: Zone1: Channel1: Phone Gateway: Slot 1 (or whichever timeslot is used for the Phone Patch
• The Deaccess Code setting on the Phone System Page should match the setting in the Phone Patch. Refer to
Phone Patch Manual for proper Deaccess code.
2
• The Target ID and Preconfigured Call settings are used to configure a default call talkgroup, and should not be
changed unless directed by Motorola Engineering:
Subscriber Configuration:
• The Subscriber codeplugs will be provided with the Phone Patch settings already configured.
• A separate phone system will need to be configured for each Phone Patch (more than one if multiple Repeaters
have a Phone Patch at the site). This is under the Signaling Systems tab in CPS.
• It is important that the “Radio ID” of the Repeater matches the “Gateway ID” of the correlating phone system in
the Portable codeplug.
• Access Code and Deaccess Code setting on the phone system profile should match the setting in the Phone Patch.
Refer to Phone Patch Manual for proper Deaccess code.
• Each channel with Phone Patch capability should have the correlating phone system profile selected on the
Channel Configuration page.
• Advanced features, like Phone Contact List and Phone Manual Dial, can be configured as needed. These changes
will require approval by the Program Manager (via Motorola Engineering).
• Open the Phone Patch and set the jumpers to the following configuration:
3
o JP6 = B : PL Detect Input
• The Phone Patch should first be reset to factory defaults. To do this, hold the “CONNECT” button on the front
panel while applying power to the unit (plugging into the Repeater). Continue to hold the “Connect” button until
the “PHONE” LED begins to flash.
• The Phone Patch can be configured from any phone by DTMF commands. Dial the phone number for the Phone
Patch and after about 14 rings, it will answer and provide two beeps. Enter the Program Access Code and listen
for five quick beeps. Commands can be entered at this point (each ending in “#”) and each will be confirmed with
five quick beeps. The following changes need to be made from the default configuration:
o “40#” : Half Duplex mode (Phone Patch will allow two-way voice traffic)
o “62#” : Direct Access mode (Phone Patch will connect to repeater immediately requiring no “answer”)
o “53# 5#” : Phone Patch will hang up after 5 seconds of dial tone (keeps Phone Patch from holding the
line with no caller on the other end)