mc93xx Ig en PDF
mc93xx Ig en PDF
mc93xx Ig en PDF
Mobile Computer
Integrator Guide
MN-003445-04 Rev A
Copyright
ZEBRA and the stylized Zebra head are trademarks of Zebra Technologies Corporation, registered in many
jurisdictions worldwide. Google, Android, Google Play and other marks are trademarks of Google LLC; Oreo is
a trademark of Mondelez International, Inc. group. All other trademarks are the property of their respective
owners. ©2020 Zebra Technologies Corporation and/or its affiliates. All rights reserved.
COPYRIGHTS & TRADEMARKS: For complete copyright and trademark information, go to www.zebra.com/
copyright.
Terms of Use
• Proprietary Statement
This manual contains proprietary information of Zebra Technologies Corporation and its subsidiaries
(“Zebra Technologies”). It is intended solely for the information and use of parties operating and maintaining
the equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to
any other parties for any other purpose without the express, written permission of Zebra Technologies.
• Product Improvements
Continuous improvement of products is a policy of Zebra Technologies. All specifications and designs are
subject to change without notice.
• Liability Disclaimer
Zebra Technologies takes steps to ensure that its published Engineering specifications and manuals are
correct; however, errors do occur. Zebra Technologies reserves the right to correct any such errors and
disclaims liability resulting therefrom.
• Limitation of Liability
In no event shall Zebra Technologies or anyone else involved in the creation, production, or delivery of the
accompanying product (including hardware and software) be liable for any damages whatsoever (including,
without limitation, consequential damages including loss of business profits, business interruption, or loss of
business information) arising out of the use of, the results of use of, or inability to use such product, even if
Zebra Technologies has been advised of the possibility of such damages. Some jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you.
Revision History
Changes to the original guide are listed below:
2
Table of Contents
Copyright ......................................................................................................................... 2
Terms of Use .................................................................................................................. 2
Revision History .............................................................................................................. 2
Accessories................................................................................................................. 28
Introduction ................................................................................................................... 28
MC93XX Accessories ................................................................................................... 28
1-Slot USB Charge Cradle with Spare Battery Charger ............................................... 31
3
Table of Contents
Setup ..................................................................................................................... 32
Charging the Device .............................................................................................. 32
Charging Temperature .................................................................................... 34
4-Slot Charge Only ShareCradle ................................................................................. 35
Setup ..................................................................................................................... 35
Charging the Devices ...................................................................................... 35
Charging Temperature .................................................................................... 36
4-Slot Ethernet ShareCradle ........................................................................................ 37
Setup ..................................................................................................................... 37
Charging the Devices ...................................................................................... 37
Daisy-chaining Ethernet ShareCradles ................................................................. 38
Ethernet Settings ............................................................................................ 39
Configuring Ethernet Proxy Settings ............................................................... 39
Configuring Ethernet Static IP Address .......................................................... 40
Establishing Ethernet Connection ......................................................................... 41
LED Indicators ....................................................................................................... 42
Charging Temperature .................................................................................... 42
16-Slot Spare Battery Charger ..................................................................................... 43
Setup ..................................................................................................................... 43
Charging the Spare Batteries .......................................................................... 43
Charging Temperature .................................................................................... 44
USB Charge/Com Snap-on Cup .................................................................................. 45
Connecting to the Device .................................................................................................. 45
Connecting the USB Charge/Com Snap-on Cup Cable to Host Computer ........... 46
Charging the Device .............................................................................................. 47
Disconnecting the USB Charge/Com Snap-on Cup .............................................. 47
MC93XX Charge Only Adapter .................................................................................... 49
Charge Only Adapter Installation .......................................................................... 50
Rubber Boot .......................................................................................................... 52
Installing the Hand Strap .............................................................................................. 54
4-Slot Charge Only ShareCradle Rack Installation ....................................................... 55
Rack Mount Installation ................................................................................................ 59
Wall Installation ............................................................................................................ 62
Bottom Tray Assembly .......................................................................................... 62
Bracket Wall Mounting .......................................................................................... 62
Settings........................................................................................................................ 64
Introduction ................................................................................................................... 64
WLAN Configuration .............................................................................................. 64
Configuring a Secure Wi-Fi Network ..................................................................... 64
Manually Adding a Wi-Fi Network ......................................................................... 65
Configuring for a Proxy Server .............................................................................. 66
4
Table of Contents
5
Table of Contents
DataWedge .................................................................................................................. 91
Introduction ................................................................................................................... 91
Basic Scanning ............................................................................................................. 91
Barcode Capture with Imager ................................................................................ 91
Profiles .......................................................................................................................... 92
Profile0 .......................................................................................................................... 92
Plug-ins ................................................................................................................. 92
Input Plug-ins ........................................................................................................ 93
Process Plug-ins ................................................................................................... 93
Output Plug-ins ...................................................................................................... 93
Profiles Screen .............................................................................................................. 93
Profile Context Menu .................................................................................................... 94
Options Menu ........................................................................................................ 94
Disabling DataWedge ............................................................................................ 95
Creating a New Profile .................................................................................................. 95
Profile Configuration ..................................................................................................... 95
Associating Applications ............................................................................................... 96
Data Capture Plus ................................................................................................. 98
Barcode Input ...................................................................................................... 100
Enabled ......................................................................................................... 100
Scanner Selection ......................................................................................... 100
Auto Switch to Default on Event ................................................................... 100
Configure Scanner Settings .......................................................................... 101
Decoders ....................................................................................................... 101
Decoder Params ........................................................................................... 103
UPC EAN Params ......................................................................................... 109
Reader Params ............................................................................................. 112
Scan Params ................................................................................................ 115
UDI Params .................................................................................................. 116
Multibarcode params .................................................................................... 116
6
Table of Contents
7
Table of Contents
8
Table of Contents
9
Table of Contents
Specifications............................................................................................................ 180
Introduction ................................................................................................................. 180
MC93XX Technical Specifications ...................................................................... 180
I/O Connector Pin-Outs ....................................................................................... 183
1-Slot USB Charge Cradle with Spare Battery Charger Technical Specifications 184
4-Slot Charge Only ShareCradle Technical Specifications ................................. 185
4-Slot Ethernet ShareCradle Technical Specifications ........................................ 185
4-Slot Spare Battery Charger Technical Specifications ...................................... 186
16-Slot Spare Battery Charger Technical Specifications .................................... 186
USB Charge/Com Snap-on Cup Technical Specifications .................................. 187
Index........................................................................................................................... 188
10
About This Guide
Introduction
This guide provides information about setting up and configuring the device and its accessories.
NOTE: Screens and windows pictured in this guide are samples and can differ from actual screens.
Documentation Set
The documentation set provides information for specific user needs, and includes:
• MC93XX Quick Start Guide - describes how to get the device up and running.
• MC93XX User Guide - describes how to use the device.
• MC93XX Integrator Guide - describes how to set up the device and accessories.
• MC93XX Regulatory Guide - provides all regulatory, service, and EULA information for the device.
11
About This Guide
Configurations
This guide covers the following configurations:
Table 1 Configurations
Software Versions
To determine the current software versions:
1. Swipe down from the Status bar to open the Quick Settings bar.
12
About This Guide
To determine the device serial number, touch About phone > Status.
• Serial number
Chapter Descriptions
Topics covered in this guide are as follows:
• Getting Started provides information on getting the device up and running for the first time.
• Accessories describes the available accessories and how to use them with the device.
• Settings provides the settings for configuring the device.
• USB Communication describes how to connect the device to a host computer using USB.
• DataWedge describes how to use and configure the DataWedge application.
• Application Deployment provides information for developing and managing applications.
• Maintenance and Troubleshooting includes instructions on cleaning and storing the device, and provides
troubleshooting solutions for potential problems during device operation.
• Specifications provides the technical specifications for the device.
Notational Conventions
The following conventions are used in this document:
• Bold text is used to highlight the following:
• Dialog box, window and screen names
• Drop-down list and list box names
• Check box and radio button names
• Icons on a screen
• Key names on a keypad
• Button names on a screen.
• Bullets (•) indicate:
• Action items
• Lists of alternatives
• Lists of required steps that are not necessarily sequential.
• Sequential lists (for example, those that describe step-by-step procedures) appear as numbered lists.
13
About This Guide
Related Documents
• MC93XX Quick Start Guide, p/n MN-003413-xx.
• MC93XX Regulatory Guide, p/n MN-003409-xx.
• MC93XX User Guide, p/n MN-003228-xx.
For the latest version of this guide and all guides, go to: www.zebra.com/support
Service Information
If you have a problem with your equipment, contact Customer Support for your region. Contact information is
available at: www.zebra.com/support.
Customer Support responds to calls by email or telephone within the time limits set forth in support
agreements.
If the problem cannot be solved by Customer Support, you may need to return the equipment for servicing and
will be given specific directions. We are not responsible for any damages incurred during shipment if the
approved shipping container is not used. Shipping the units improperly can possibly void the warranty.Remove
the microSD card from the device before shipping for service.
If the device was purchased from a business partner, contact that business partner for support.
14
About This Guide
If the manufacturing label is worn or missing, use an NFC enabled device to read the NFC tag under the
battery compartment. You can download the NFC Reader application for free from the Google Play store.
Manufacturing Label
15
Getting Started
Introduction
This chapter provides information for getting the device up and running for the first time.
Unpacking
Carefully remove all protective material from the device and save the shipping container for later
storage and shipping.
Inspect the equipment for damage. If any equipment is missing or damaged, contact the Zebra
Support Center immediately.
16
Getting Started
Setup
To start using the device for the first time:
• Install a microSD card (optional)
• Install the battery
• Charge the device
• Power on the device.
The microSD card slot provides secondary non-volatile storage. The slot is located under the keypad module.
Refer to the documentation provided with the card for more information, and follow the manufacturer’s
recommendations for use. It is strongly recommended that prior to use, you must format the microSD card on
the device.
NOTE: The following microSD cards were tested and are validated for use with the MC93XX:
• SanDisk 16GB (SDSDQ-016G-A11M)
• SanDisk 32GB (SDSDQ-032G-A11M)
• SanDisk 64GB (SDSDQUA-064G-U46A)
• SanDisk 128GB (SDSDQUI-128G-A46)
• SanDisk 200GB (SDSDQUAN-200G-A4A).
CAUTION: Follow proper electrostatic discharge (ESD) precautions to avoid damaging the microSD card. Proper ESD pre-
cautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded.
17
Getting Started
Screwdriver
Keypad Latches
NOTE: If the keypad latches are hard to move, use a screwdriver to gently slide them towards the bottom of the device.
Keypad Screws
Keypad
18
Getting Started
10.Insert the microSD card into the card holder door ensuring that the card slides into the holding tabs on each
side of the door.
19
Getting Started
11.Close the microSD card holder door and slide the door to the Lock position.
12.Align the keypad along the bottom ridge of the device, and then lay it flat.
20
Getting Started
13.Using a Torx T8 screwdriver with a large grip and a long shaft, secure the keypad to the device using the
two screws. Torque screws to 5.8 kgf-cm or 5.0 lbf-in.
Keypad Screws
14.Turn the device over so that the keypad latches are visible.
15.Slide both the keypad latches toward the top of the device.
Keypad Latches
21
Getting Started
16.Using a Torx T8 screwdriver, replace the two keypad latch screws inside the battery slot and torque to 5.8
kgf-cm or 5.0 lbf-in.
Charging Communication
22
Getting Started
Status Indications
Off • The battery is not charging.
• The device is not inserted correctly in the cradle or connected to a
power source.
• Cradle is not powered.
Slow Blinking Amber • Battery is charging, but the battery is fully depleted and does not yet
Every 3 seconds have sufficient charge to power the device.
• After battery removal, indicates that the device is in hot swap mode with
connectivity persistence.
The 7000mAh PowerPrecision+ standard battery charges from 0% to 90% in less than 3.5 hours at room
temperature using a Zebra accessory.
The 5000mAh PowerPrecision+ freezer battery charges from 0% to 90% in less than 2.5 hours at room
temperature using a Zebra accessory.
The 7000mAh PowerPrecision+ non-incendive battery charges from 0% to 90% in less than 3.5 hours at room
temperature using a Zebra accessory.
Charge batteries in temperatures from 0°C to 40°C (32°F to 104°F). The device or cradle always performs
battery charging in a safe and intelligent manner. At higher temperatures, for example at approximately +37°C
(+98°F), the device or cradle may for small periods of time alternately enable and disable battery charging to
keep the battery at acceptable temperatures. The device and cradle indicates when charging is disabled due to
abnormal temperatures via its LED.
23
Getting Started
Backup Power
The device is equipped with a super-capacitor (supercap) to provide backup power to the device when the
main battery is removed. The supercap will retain random access memory (RAM) data in memory for
approximately five minutes after the main battery is removed during Hot Swap.
IMPORTANT: The supercap is automatically charged from the main battery and requires approximately fifteen
minutes to fully charge.
The device provides a Hot Swap mode where you can replace the battery without powering off the device.
When you remove the battery, the display turns off and the devices enters the Hot Swap mode. WLAN and
Bluetooth connectivity are retained for the first 30 seconds (indicated by a flashing amber LED). After 30
seconds, the device enters a critical suspend mode with RAM data persistence for approximately 5 minutes. In
the critical suspend mode, WLAN and Bluetooth radios are disabled and will only resume if you insert a battery
with sufficient charge into the device.
CAUTION: To prevent damage to the device, DO NOT perform a hot swap during a device boot up session.
IMPORTANT: The supercap requires time to recharge after performing a Hot Swap or after the main battery is
fully depleted. It can take up to 15 minutes to fully charge the supercap. Hot Swap mode will not retain data
unless the supercap is fully charged.
24
Getting Started
Screwdriver
Keypad Latches
NOTE: If the keypad latches are hard to move, use a screwdriver to gently slide them towards the bottom of the device.
Keypad Screws
Keypad
25
Getting Started
9. Using a Torx T8 screwdriver with a large grip and a long shaft, secure the keypad to the device using the
two screws. Torque screws to 5.8 kgf-cm or 5.0 lbf-in.
Keypad Screws
10.Turn the device over so that the keypad latches are visible.
26
Getting Started
11.Slide both the keypad latches toward the top of the device.
Keypad Latches
12.Using a Torx T8 screwdriver, replace the two keypad latch screws inside the battery slot and torque to 5.8
kgf-cm or 5.0 lbf-in.
27
Accessories
Introduction
This chapter provides information for using the accessories for the device.
MC93XX Accessories
The table below lists the accessories available for the device.
28
Accessories
29
Accessories
30
Accessories
31
Accessories
• Synchronizes information between the mobile computer and a host computer. With customized or third
party software, it can also synchronize the mobile computer with corporate databases.
• Compatible with the following batteries:
• 7000mAh PowerPrecision+ standard battery
• 5000mAh PowerPrecision+ freezer battery
• 7000mAh PowerPrecision+ non-incendive battery.
Setup
Figure 20 1-Slot USB Charge Cradle with Spare Battery Charger Setup
AC Line Cord
Power Supply
USB Cable
32
Accessories
2. Slide the device into the slot in the cradle. The device Charge LED Indicator, indicates the battery charging
status.
3. Gently press down on the device to ensure proper contact.
4. When charging is complete, remove the devices from the cradle slot.
The 1-Slot USB charge cradle charges the MC93XX’s main battery and a spare battery simultaneously.
33
Accessories
The MC93XX’s Charge LED indicates the status of the battery charging in the device. See LED Charge
Indicators for charging status indications.
Table 5 LED Charge Indicators
Status Indications
Off • The battery is not charging.
• The device is not inserted correctly in the cradle or connected to a
power source.
• Cradle is not powered.
Slow Blinking Amber • Battery is charging, but the battery is fully depleted and does not yet
Every 3 seconds have sufficient charge to power the device.
Solid Amber • Battery is charging.
Solid Green • Battery charging is complete.
Fast Blinking Red Charging error. For example:
2 blinks/second • Temperature is too low or too high.
• Charging has gone on too long without completion (typically eight
hours).
Solid Red • Battery is charging and battery is at the end of useful life.
• Charging complete and battery is at the end of useful life.
The 7000mAh PowerPrecision+ standard battery charges from 0% to 90% in less than 3.5 hours at room
temperature using a Zebra accessory.
The 5000mAh PowerPrecision+ freezer battery charges from 0% to 90% in less than 2.5 hours at room
temperature using a Zebra accessory.
The 7000mAh PowerPrecision+ non-incendive battery charges from 0% to 90% in less than 3.5 hours at room
temperature using a Zebra accessory.
Charging Temperature
Charge batteries in temperatures from 0°C to 40°C (32°F to 104°F). The device or cradle always performs
battery charging in a safe and intelligent manner. At higher temperatures, for example at approximately +37°C
(+98°F), the device or cradle may for small periods of time alternately enable and disable battery charging to
keep the battery at acceptable temperatures. The device and cradle indicates when charging is disabled due to
abnormal temperatures via its LED.
34
Accessories
CAUTION: Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines.
Setup
AC Line Cord
Power Supply
DC Line Cord
35
Accessories
Power LED
Charging Temperature
Charge batteries in temperatures from 0°C to 40°C (32°F to 104°F). The device or cradle always performs
battery charging in a safe and intelligent manner. At higher temperatures, for example at approximately +37°C
(+98°F), the device or cradle may for small periods of time alternately enable and disable battery charging to
keep the battery at acceptable temperatures. The device and cradle indicates when charging is disabled due to
abnormal temperatures via its LED.
36
Accessories
CAUTION: Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines.
Setup
AC Line Cord
Power Supply
Primary Port
Router
DC Line Cord
Ethernet Cable
37
Accessories
Power LED
Daisy-chain up to ten 4-Slot Ethernet ShareCradles to connect several cradles to an Ethernet network. Use
either a straight or crossover cable. Daisy-chaining should not be attempted when the main Ethernet
connection to the first cradle is 10 Mbps as throughput issues will almost certainly result.
38
Accessories
To Switch
To Power Supply
Ethernet Settings
The following settings can be configured when using Ethernet communication:
• Proxy Settings
• Static IP.
1. Swipe down from the status bar to open the quick access panel and then touch .
39
Accessories
NOTE: When entering proxy addresses in the Bypass proxy for field, do not use spaces or carriage returns between ad-
dresses.
10.In the Bypass proxy for text box, enter addresses for web sites that do not require to go through the proxy
server. Use the separator comma “,” between addresses.
11.Touch MODIFY.
12.Touch .
1. Swipe down from the status bar to open the quick access panel and then touch .
40
Accessories
14.Touch .
1. Swipe down from the status bar to open the quick access panel and then touch .
41
Accessories
LED Indicators
There are two green LEDs on the side of the cradle. These green LEDs light and blink to indicate the data
transfer rate.
Charging Temperature
Charge batteries in temperatures from 0°C to 40°C (32°F to 104°F). The device or cradle always performs
battery charging in a safe and intelligent manner. At higher temperatures, for example at approximately +37°C
(+98°F), the device or cradle may for small periods of time alternately enable and disable battery charging to
keep the battery at acceptable temperatures. The device and cradle indicates when charging is disabled due to
abnormal temperatures via its LED.
42
Accessories
CAUTION: Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines.
Setup
AC Line Cord
Power Supply
DC Line Cord
43
Accessories
Power LED
2. Insert the battery into a spare battery charging slot and gently press down on the battery to ensure proper
contact.
The Spare Battery Charging LEDs on the front of the cradle indicates the spare battery charging status. The
following table specifies charging indicators.
State Indication
Off • The battery is not charging.
• The battery is not inserted correctly in the cradle.
• Cradle is not powered.
Solid Amber • Battery is charging.
Solid Green • Battery charging is complete.
Fast Blinking Red Charging error. For example:
2 blinks/second • Temperature is too low or too high.
• Charging has gone on too long without completion (typically eight
hours).
Solid Red • Battery is charging and battery is at the end of useful life.
• Charging complete and battery is at the end of useful life.
Charging Temperature
Charge batteries in temperatures from 0°C to 40°C (32°F to 104°F). The device or cradle always performs
battery charging in a safe and intelligent manner. At higher temperatures, for example at approximately +37°C
(+98°F), the device or cradle may for small periods of time alternately enable and disable battery charging to
keep the battery at acceptable temperatures. The device and cradle indicates when charging is disabled due to
abnormal temperatures via its LED.
44
Accessories
NOTE: To function properly, remove the lower part of the rubber boot or the entire rubber boot before placing the
device in a charging cradle.
Insert the device straight onto the USB Charge/Com Snap-on Cup until the device touches the bottom of the
cable cup.
45
Accessories
USB Cable
46
Accessories
Power Supply
USB Cable
Refer to the Charging the Main Battery section for information on charging indicator statuses.
47
Accessories
48
Accessories
49
Accessories
2. Peel and remove the adhesive from the back of the adapter.
3. Insert the adapter into the MC9XXX cradle and adhere to the bottom of the cradle.
50
Accessories
51
Accessories
Rubber Boot
Shim
2. Slide the top of the device into the top of the rubber boot.
52
Accessories
3. Grasp the bottom of the rubber boot and place over the bottom of the device.
4. Turn the device over and ensure that the two alignment tabs completely fit into the two alignment slots on
the device.
Tabs
NOTE: To charge the device in a cradle, completely remove the rubber boot.
53
Accessories
2. Thread and pull-through the longer section through the opening near the battery.
54
Accessories
NOTE: Ensure tie wrap buckle is on side of power supply. Tie wrap buckle on top of power supply interferes with top tray.
Studs (4)
55
Accessories
MC93
MC93
MC93
MC93
Safety Screws(2)
56
Accessories
11.Secure top tray to bottom tray with 4 M5 screws (two on each side).
57
Accessories
See Rack Mount Installation on page 59 for installing the bracket assembly onto a rack.
58
Accessories
1. Secure mounting brackets to both sides of top tray with four M5 screws (two on each side). For 4-Slot
cradles, position the flange for horizontal installation. For 4-Slot Battery Chargers, position the flange for
25° installation.
Flange
Flange
CAUTION: Install mounting bracket with 4-Slot cradle at a maximum height of four feet from ground.
Install mounting bracket with 4-Slot Battery Charger at a maximum height of three feet from ground.
NOTE: Distance between two horizontal mounted brackets should be at least 14” apart (from top of one flange to the top of
the next flange).
Distance between a horizontal mounted bracket and a 25° mounted bracket should be at least 16.25” apart (from top of one
flange to the top of the next flange).
There should be enough clearance (2.75”) between the top of the device and the bottom of the mounting bracket above.
2. Install two rack system screws for top of mounting brackets. The screw heads should protrude half way
from the rail.
59
Accessories
Rack Screws
3. Align the mounting bracket’s top mounting key holes with the screws.
4. Place the brackets on the screws.
MC93
MC93
MC93
MC93
14 “
MC93
MC93
MC93
MC93
60
Accessories
CAUTION: Installer should ensure that all building codes are followed when connecting the power supplies to an AC power
source.
While installing the brackets, power supplies and cables:
• Use tie wraps to secure cables to the bracket and rails.
• Coil cables wherever possible.
• Route power cables along the rails.
• Route inter-cradle cables to the side rails and then from the rails to the bracket.
61
Accessories
Wall Installation
Use the Rack/Wall Mount Bracket to mount four 4-Slot Battery Chargers or a cradle on a wall. When installing
on a wall, first assemble the bottom tray, install the bottom tray on the wall and then assemble the top tray.
Use mounting hardware (screws and/or anchors) appropriate for the type of wall mounting the bracket onto.
The Mount Bracket mounting slots dimensions are 5 mm (0.2 in.). Fasteners must be able to hold a minimum
of 20 Kg (44 lbs.)
For proper installation consult a professional installer. Failure to install the bracket properly can possibly result
in damage to the hardware.
CAUTION: Install mounting bracket with 4-Slot cradle at a maximum height of four feet from ground.
Install mounting bracket with 4-Slot Battery Charger at a maximum height of three feet from ground.
See steps 1 through 5 in 4-Slot Charge Only ShareCradle Rack Installation on page 55 for instructions.
1. Drill holes and install anchors according to the template supplied with the bracket.
2. Install two screws for bottom of bracket. The screw heads should protrude 2.5 mm (0.01”) from the wall.
398 mm
22.85 mm
3. Align the mounting bracket’s bottom mounting key holes with the screws.
4. Hang the bracket on the screws.
62
Accessories
7. Assemble the four 4-Slot Battery Chargers or cradle onto the bracket. See steps 7 through 11 in 4-Slot
Spare Battery Charger Rack Installation on page 59.
8. Route cables and connect to power source.
CAUTION: Installer should ensure that all building codes are followed when connecting the power supplies to an AC power
source.
While installing the brackets, power supplies and cables:
• Use tie wraps to secure cables to the bracket and rails.
• Coil cables wherever possible.
• Route power cables along the rails.
• Route inter-cradle cables to the side rails and then from the rails to the bracket.
63
Settings
Introduction
This chapter describes settings available for configuring the device.
WLAN Configuration
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
64
Settings
7. If the network security is WEP or WPA/WPS2 PSK, enter the required password and then touch Connect.
8. If the network security is 802.1x EAP:
• Touch the EAP method drop-down list and select PEAP, TLS, TTLS, or LEAP.
• Touch the Phase 2 authentication drop-down list and select an authentication method.
• If required, touch CA certificate and select a Certification Authority (CA) certificate. Note: Certificates
are installed using the Security settings.
• If required, touch User certificate and select a user certificate. Note: User certificates are installed
using the Location & security settings.
• If required, in the Identity text box, enter the username credentials.
• If desired, in the Anonymous identity text box, enter an anonymous identity username.
• If required, in the Password text box, enter the password for then given identity.
NOTE: By default, the network Proxy is set to None and the IP settings is set to DHCP. See Configuring for a Proxy Server
for setting connection to a proxy server and see Configuring the Device to Use a Static IP Address for setting the device to
use a static IP address.
9. Touch Connect.
10.Touch .
Manually add a Wi-Fi network if the network does not broadcast its name (SSID) or add a Wi-Fi network when
out of range.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
65
Settings
NOTE: By default, the network Proxy is set to None and the IP settings is set to DHCP. See Configuring for a Proxy Server
for setting connection to a proxy server and see Configuring the Device to Use a Static IP Address for setting the device to
use a static IP address.
10.Touch Save. To connect to the saved network, touch and hold on the saved network and select Connect to
network.
11.Touch .
A proxy server is a server that acts as an intermediary for requests from clients seeking resources from other
servers. A client connects to the proxy server and requests some service, such as a file, connection, web
page, or other resource, available from a different server. The proxy server evaluates the request according to
its filtering rules. For example, it may filter traffic by IP address or protocol. If the request is validated by the
filter, the proxy provides the resource by connecting to the relevant server and requesting the service on behalf
of the client.
It is important for enterprise customers to be able to set up secure computing environments within their
companies, making proxy configuration essential. Proxy configuration acts as a security barrier ensuring that
the proxy server monitors all traffic between the Internet and the intranet. This is normally an integral part of
security enforcement in corporate firewalls within intranets.
66
Settings
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
7. In the Proxy hostname text box, enter the address of the proxy server.
8. In the Proxy port text box, enter the port number for the proxy server.
9. In the Bypass proxy for text box, enter addresses for web sites that are not required to go through the
proxy server. Use a comma “,” between addresses. Do not use spaces or carriage returns between
addresses.
10.Touch Connect.
11.Touch .
By default, the device is configured to use Dynamic Host Configuration Protocol (DHCP) to assign an Internet
protocol (IP) address when connecting to a wireless network.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
67
Settings
13.Touch .
Wi-Fi Preferences
Use the Wi-Fi preferences to configure advanced Wi-Fi settings. From the Wi-Fi screen scroll down to the
bottom of the screen and touch Wi-Fi preferences.
• Open network notification - When enabled, notifies the user when an open network is available.
• Advanced - Touch to expand options.
• Additional settings - See Additional Settings.
• Install Certificates – Touch to install certificates.
• Network rating provider - Disabled (AOSP devices). To help determine what constitutes a good Wi-Fi
network, Android supports external Network rating providers that provide information about the quality of
68
Settings
open Wi-Fi networks. Select one of the providers listed or None. If none are available or selected, the
Connect to open networks feature is disabled.
• MAC address - Displays the Media Access Control (MAC) address of the device when connecting to
Wi-Fi networks.
• IP address - Displays the IP address of the device when connecting to Wi-Fi networks.
NOTE: Additional Wi-Fi settings are for the device, not for a specific wireless network.
Use the Additional Settings to configure additional Wi-Fi settings. To view the additional Wi-Fi settings, scroll
to the bottom of the Wi-Fi screen and touch Wi-Fi Preferences > Advanced > Additional settings.
• Regulatory
• Country Selection - Displays the acquired country code if 802.11d is enabled, else it displays the
currently selected country code.
• Region code - Displays the current region code.
• Band and Channel Selection
• Wi-Fi frequency band - Set the frequency band to: Auto (default), 5 GHz only or 2.4 GHz only.
• Available channels (2.4 GHz) - Touch to display the Available channels menu. Select specific
channels and touch OK.
• Available channels (5 GHz) - Touch to display the Available channels menu. Select specific channels
and touch OK.
• Logging
• Advanced Logging – Touch to enable advanced logging or change the log directory.
• Wireless logs - Use to capture Wi-Fi log files.
• Fusion Logger - Touch to open the Fusion Logger application. This application maintains a history
of high level WLAN events which helps to understand the status of connectivity.
• Fusion Status - Touch to display live status of WLAN state. Also provides information about the
device and connected profile.
• About
• Version - Displays the current Fusion information.
Wi-Fi Direct
Wi-Fi Direct devices can connect to each other without having to go through an access point. Wi-Fi Direct
devices establish their own ad-hoc network when required, letting you see which devices are available and
choose which one you want to connect to.
2. Touch Wi-Fi > Wi-Fi preferences > Advanced > Wi-Fi Direct. The device begins searching for another
Wi-Fi Direct device.
69
Settings
Wi-Fi Protected Setup (WPS) is a feature allowing devices to easily connect to Wi-Fi access points without
typing a long password.
1. On the device, swipe down from the status bar and then touch .
2. Touch Wi-Fi > Wi-Fi preferences > Advanced > WPS Push Button. A dialog box displays.
3. On the wireless router, locate the WPS button. The device connects to the wireless router.
70
Settings
Wi-Fi Protected Setup (WPS) is a feature allowing devices to easily connect to Wi-Fi access points without
typing a long password.
2. Go to the Add WPS Client screen. Refer to the wireless router user documentation specific information.
3. On the device, swipe down from the status bar, and then touch .
4. Touch Wi-Fi > Wi-Fi preferences > Advanced > WPS Pin Entry. A dialog box displays with an Pin
number.
5. On the router, enter the Pin number. The device connects to the wireless router.
Use the Device security settings to set preferences for locking the screen.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
NOTE: Options vary depending upon the policy of some apps, such as email.
• Screen lock - Touch to configure the device to require a slide, pattern, PIN, or password to unlock the
screen.
• None - Disable screen unlock security.
• Swipe - Slide the lock icon to unlock the screen.
• Pattern - Draw a pattern to unlock screen. See Setting Screen Unlock Using Pattern for more
information.
• PIN - Enter a numeric PIN to unlock screen. See Setting Screen Lock Using PIN for more information.
• Password - Enter a password to unlock screen. See Setting Screen Unlock Using Password for more
information.
Lock the screen to protect access to data on the device. Some email accounts require locking the screen. The
Locking feature functions differently in Single-user versus Multiple-user mode.
When locked, a slide, pattern, PIN or password is required to unlock the device. Press the Power button to lock
the screen. The device also locks after a pre-defined time-out.
71
Settings
Press and release the Power button to wake the device. The Lock screen displays.
Slide the screen up to unlock. If the Pattern screen unlock feature is enabled, the Pattern screen appears
instead of the Lock screen.
If the PIN or Password screen unlock feature is enabled, enter the PIN or password after unlocking the screen.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
10.Touch . The next time the device goes into suspend mode a PIN is required upon waking.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
72
Settings
10.Touch . The next time the device goes into suspend mode a password is required upon waking.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
73
Settings
11.Touch . The next time the device goes into suspend mode a pattern is required upon waking.
Showing Passwords
To set the device to briefly show password characters as the user types:
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
Remapping a Button
Buttons on the device can be programmed to perform different functions or as shortcuts to installed apps.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
74
Settings
4. Touch the BUTTON REMAPPING tab or the SHORTCUT tab that lists the available functions and
applications.
5. Touch a function or application shortcut to map to the button.
NOTE: If you select an application shortcut, the application icon appears next to the button on the Key Programmer screen.
6. Touch .
Accounts
Use the Accounts settings to add, remove, and manage accounts. Use these settings to control how
applications send, receive, and sync data on their own schedules, and whether applications can synchronize
user data automatically.
Applications may also have their own settings to control how they synchronize data; see the documentation for
those applications for details.
75
Settings
Language Usage
Use the Language & input settings to change the device’s language, including words added to the dictionary.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
5. Touch and hold to the right of the desired language, then drag it to the top of the list.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
2. Touch System > Languages & input > Advanced > Personal dictionary.
3. If prompted, select the language where this word or phase is stored.
4. Touch + to add a new word or phrase to the dictionary.
5. Enter the word or phrase.
6. In the Shortcut text box, enter a shortcut for the word or phrase.
7. Touch .
Keyboard Settings
Use the Languages & input settings to configure the on-screen keyboards. The device contains the following
keyboard settings:
• Enterprise Keyboard
• Gboard - GMS devices only.
• Physical keyboard
Refer to the PTT Express User Guide at www.zebra.com/support for information on configuring the PTT
Express Client application.
RxLogger
RxLogger is a comprehensive diagnostic tool that provides application and system metrics, allows for the
creation of custom plug-ins, and diagnoses device and application issues. RxLogger logs the following
information: CPU load, memory load, memory snapshots, battery consumption, power states, wireless logging,
76
Settings
cellular logging, TCP dumps, Bluetooth logging, GPS logging, logcat, FTP push/pull, ANR dumps, etc. All
generated logs and files are saved onto flash storage on the device (internal or external).
Figure 75 RxLogger
RxLogger Configuration
RxLogger is built with an extensible plug-in architecture and comes packaged with a number of plug-ins
already built-in. The included plug-ins are described below.
77
Settings
To open the configuration screen, from the RxLogger home screen touch Settings.
RxLogger Settings
ANR Module
Application Not Responsive (ANR) indicates that a running application’s UI thread is not responding for a
specified time period. RxLogger is able to detect this condition and trigger a copy of the call stack trace of the
unresponsive application into the log directory. The event is also indicated in the high level CSV log.
• Enable Module - Enables logging for this module.
• Log path - Specifies the default log path to store the ANR log files.
• Collect Historic ANRs - Collects ANR trace files from the system.
Kernel Module
The Kernel Module captures kmsg from the system.
• Enable Module - Enables logging for this kernel module.
• Log path - Specifies the high level log path for storage of all kernel logs. This setting applies globally to all
kernel buffers.
• Kernel Log filename - Specifies the base log filename for this kernel buffer. The current file count is
appended to this name.
• Max Kernel log file size - Specifies the maximum size, in megabytes, of an individual log file.
78
Settings
• Kernel Log interval - Sets the interval, in seconds, on which to flush the log buffer to the file.
• Kernel Log file count - Specifies the number of log files to keep and rotate through. Each log file is subject
to the max log size option.
• Enable System Timestamp in Kernel Log - Enables system timestamps in kernel logs.
• System Timestamp Interval - Sets the interval, in seconds, between system timestamps.
• Enable Logcat Integration override - Enables logcat integration overrides.
Logcat Module
Logcat is an essential debugging tool on Android devices. RxLogger provides the ability to record data from all
four of the available logcat buffers. The Logcat plug-in can collect data from multiple logcat buffers provided by
the system, which are the main, event, radio, and system buffers. Each of the settings are available for each
buffer independently unless otherwise noted.
• Enable Module - Enables logging for this module.
• Log path - Specifies the high level log path for storage of all logcat logs. This setting applies globally to all
logcat buffers.
• Enable main logcat - Enables logging for this logcat buffer.
• Main Log interval (sec) - Sets the interval, in seconds, on which to flush the log buffer to the file.
• Main Log filename - Specifies the base log filename for this logcat buffer. The current file count is
appended to this name.
• Main Log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
• Main log file size (MB) - Specifies the maximum size, in megabytes, of an individual log file.
• Main log filter - Custom logcat filter to run on the main buffer.
• Enable event logcat - Enables event logging for this logcat buffer.
• Event log interval (sec) - Sets the interval, in seconds, on which to flush the log buffer to the file.
• Event log filename - Specifies the base log filename for this logcat buffer. The current file count is
appended to this name.
• Event log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
• Event log file size (MB) - Specifies the maximum size, in kilobytes, of an individual log file.
• Event log filter - Custom logcat filter to run on the event buffer.
• Enable radio logcat - Enables logging for this logcat buffer.
• Radio log interval (sec) - Sets the interval, in seconds, on which to flush the log buffer to the file.
• Radio log filename - Specifies the base log filename for this logcat buffer. The current file count is
appended to this name.
• Radio log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
• Radio log file size (MB) - Specifies the maximum size, in kilobytes, of an individual log file.
• Radio log filter -Custom logcat filter to run on the radio buffer.
79
Settings
LTS Module
The LTS (Long Term Storage) Module captures data over a long duration of time without losing any data.
Whenever a file is done being written, LTS saves it as a GZ file in an organized path for later use.
• Enable Module - Enables logging for this module.
• Storage Directory - Specifies the high level log path for storage of all logcat logs. This setting applies
globally to all logcat buffers.
Ramoops Module
The Ramoops Module captures the last kmsg from the device.
• Enable Module - Enables logging for this module.
• Log path - Specifies the high level log path for storage of all ramoops logs. This setting applies globally to
all Ramoops buffers.
80
Settings
• Base filename - Specifies the base log filename for this kernal buffer. The current file count is appended to
this name.
• Ramoops file count - Specifies the number of log files to keep and rotate through. Each log file is subject
to the log size option.
Resource Module
The Resource Module captures device information and system statistics at specified intervals. The data is
used to determine the health of the device over a period of time.
• Enable Module - Enables logging for this module.
• Log Path - Specifies the high level log path for storage of all resource logs. This setting applies globally to
all resource buffers.
• Resource Log interval - Sets the interval, in seconds, on which to flush the log buffer to the file.
• Resource Log file size - Specifies the maximum size, in megabytes, of an individual log file.
• Resource Log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
• Power - Enables or disables the collection of Battery statistics.
• System Resource- Enables or disables the collection of System Resource information.
• Network - Enables or disables the collection of Network status.
• Bluetooth - Enables or disables the collection of Bluetooth information.
• Light - Enables or disables the collection of ambient light level.
• Heater - Not supported.
Snapshot Module
The Snapshot Module collects detailed device statistics at an interval to see detailed device information.
• Enable Module - Enables logging for this module.
• Log Path - Specifies the base path to use to store the snapshot files
• Log filename - Specifies the base filename for all the snapshot files. The current file count is appended to
this name.
• Log Interval (sec) - Specifies the interval, in seconds, on which to invoke a detailed snapshot.
• Snapshot file count - The maximum number of Snapshot files to keep at any one time.
• Top - Enables or disables the running of the top command for data collection.
• CPU Info - Enables detailed per process CPU logging in the snapshot.
• Memory Info - Enables logging of detailed per process memory usage in the snapshot.
• Battery Info - Enables logging of detailed power information including battery life, on time, charging, and
wake locks.
• Wake Locks - Enables or disables the collection of the sys/fs wake_lock information.
• Time in State - Enables or disables the collection of the sys/fs cpufreq for each core.
• Processes - Enables dumping the complete process list in the snapshot.
• Threads - Enables dumping all processes and their threads in the snapshot.
• Properties - Enables dumping of all system properties on the device. This includes build/version
information as well as state information.
• Interfaces - Enables or disables the running of the netcfg command for data collection.
• IP Routing Table - Enables or disables the collection of the net route for data collection.
81
Settings
• Connectivity - Enables or disables the running of the dumpsys connectivity command for data collection.
• Wifi - Enables or disables the running of the dumpsys wifi command for data collection.
• File systems - Enables dumping of the available volumes on the file system and the free storage space for
each.
• Usage stats - Enables dumping of detailed usage information for each package on the device. This
includes the number of starts and duration of each run.
TCPDump Module
The TCPDump Module captures TCP data that happens over the device’s networks.
• Enable Module - Enables logging for this module.
• Log path - Specifies the location to store the TCPDump output log files.
• Base filename - Specifies the base filename to use when storing the TCPDump files. The index number of
the current log file is appended to the filename.
• Tcpdump file size (MB) - Specifies the maximum file size, in megabytes, for each log file created.
• Tcpdump file count - Specifies the number of log files to cycle through when storing the network traces.
Tombstone Module
The Tombstone Module collects tombstone (Linux Native Crashes) logs from the device.
• Enable Module - Enables logging for this module.
• Log path - Specifies the location to store the Tombstone output log files.
• Collect Historic tombstones - Collects new and existing tombstone files.
Configuration File
RxLogger configuration can be set using an XML file. The config.xml configuration file is located in the
RxLogger\config folder. Copy the file from the device to a host computer using a USB connection. Edit the
configuration file and then replace the XML file on the device. There is no need to stop and restart the
RxLogger service since the file change is automatically detected.
Enabling Logging
To enable logging:
2. Touch Start.
3. Touch .
Disabling Logging
To disable logging:
2. Touch Stop.
82
Settings
3. Touch .
RxLogger Utility
RxLogger Utility is a data monitoring application for viewing logs in the device while RxLogger is running. Logs
and RxLogger Utility features are accessed in the App View or the Overlay View.
App View
Viewing Logs
To view logs:
83
Settings
1. Touch the Main Chat Head icon. The Overlay View screen appears.
2. Touch a log to open it. The user can open many logs with each displaying a new sub Chat Head.
3. If necessary, scroll left or right to view additional Sub Chat Head icons.
4. Touch a Sub Chat Head to display the log contents.
84
Settings
Backup
RxLogger Utility allows the user to make a zip file of the RxLogger folder in the device, which by default
contains all the RxLogger logs stored in the device.
Archive Data
View all the RxLogger logs stored in the default RxLogger directory. Logs viewed in the Archive window are not
live.
Figure 81 Archive
To view the log files, touch ARCHIVE DATA and then touch a log file.
Overlay View
Use Overlay View to display RxLogger information while using other apps or on the home screen. Overlay
View is accessed using the Main Chat Head.
85
Settings
1. Open RxLogger.
2. Touch > Toggle Chat Head. The Main Chat Head icon appears on the screen.
3. Touch and drag the Main Chat head icon to move it around the screen.
Viewing Logs
To view logs:
1. Touch the Main Chat Head icon. The Overlay View screen appears.
2. Touch a log to open it. The user can open many logs with each displaying a new sub Chat Head.
3. If necessary, scroll left or right to view additional Sub Chat Head icons.
86
Settings
About Phone
Use About phone settings to view information about the device. Swipe down from the Status bar to open the
Quick Access panel and then touch > System > About phone.
87
Settings
88
USB Communication
Introduction
This chapter provides information for transferring files between the device and a host computer.
When connecting the device to a host computer, follow the host computer’s instructions for connecting
and disconnecting USB devices, to avoid damaging or corrupting files.
Transferring Files
NOTE: Use Transfer files to copy files between the device (internal memory) and the host computer.
1. Place the device into a USB cradle or into the USB snap on cup.
2. Pull down the Notification panel and touch USB charging this device.
By default, Charge this device is selected.
89
USB Communication
Transferring Photos
NOTE: Use Photo Transfer Protocol (PTP) to copy photos from the internal memory to the host computer.
CAUTION: Carefully follow the host computer’s instructions to disconnect USB devices correctly to avoid losing information.
90
DataWedge
Introduction
This chapter applies to DataWedge on Android devices. DataWedge is an application that reads data,
processes the data and sends the data to an application.
Basic Scanning
Scanning can be performed using the following:
91
DataWedge
Profiles
DataWedge is based on profiles and plug-ins. A profile contains information on how DataWedge should
behave with different applications.
Using profiles, each application can have a specific DataWedge configuration. For example, each user
application can have a profile which outputs scanned data in the required format when that application comes
to the foreground. DataWedge can be configured to process the same set of captured data differently based on
the requirements of each application.
DataWedge includes the following pre-configured profiles which support specific built-in applications:
• Visible profiles:
• Profile0 - created automatically the first time DataWedge runs. Generic profile used when there are no
user created profiles associated with an application.
• Launcher - enables scanning when the Launcher is in foreground.
• DWDemo - provides support for the DWDemo application.
Some Zebra applications are capable of capturing data by scanning. DataWedge is pre-loaded with private
and hidden profiles for this purpose. There is no option to modify the private profiles.
Profile0
Profile0 can be edited but cannot be associated with an application. That is, DataWedge allows manipulation
of plug-in settings for Profile0 but it does not allow assignment of a foreground application. This configuration
allows DataWedge to send output data to any foreground application other than applications associated with
user-defined profiles when Profile0 is enabled.
Profile0 can be disabled to allow DataWedge to only send output data to those applications which are
associated in user-defined profiles. For example, create a profile associating a specific application, disable
Profile0 and then scan. DataWedge only sends data to the application specified in the user-created profile.
This adds additional security to DataWedge enabling the sending of data only to specified applications.
Plug-ins
A plug-in is a software module utilized in DataWedge to extend its functionality to encompass technologies
such as barcode scanning. The plug-ins can be categorized into three types based on their operations:
• Input Plug-ins
• Output Plug-ins
• Process Plug-ins.
92
DataWedge
Input Plug-ins
An Input Plug-in supports an input device, such as a barcode scanner contained in, or attached to the device.
DataWedge contains base plug-ins for these input devices.
Barcode Scanner Input Plug-in – The Barcode Scanner Input Plug-in is responsible for reading data from the
integrated barcode scanner and supports different types of barcode readers including laser, imager and
internal camera. Raw data read from the barcode scanner can be processed or formatted using Process
Plug-ins as required. DataWedge has built-in feedback functionality for the barcode scanner to issue user
alerts. The feedback settings can be configured according to user requirement.
Process Plug-ins
Process Plug-ins are used in DataWedge to manipulate the received data according to the requirement,
before sending to the foreground application via the Output Plug-in.
• Basic Data Formatting Process Plug-in – The Basic Data Formatting Plug-in allows DataWedge to add a
prefix and/or a suffix to the captured data before passing it to an Output Plug-in.
• Advanced Data Formatting Process Plug-in – The Advanced Data Formatting Plug-in allows
DataWedge to apply rules (actions to be performed based on defined criteria) to the data received via an
input plug-in before passing it to an Output Plug-in.
Output Plug-ins
Output Plug-ins are responsible for sending the data from Input Plug-ins to a foreground application on the
device.
• Keystroke Output Plug-in – The Keystroke Output Plug-in collects and sends data received from the Input
Plug-in to the foreground applications by emulating keystrokes.
• Intent Output Plug-in – The Intent Output Plug-in collects and sends data received from the Input Plug-ins
to foreground applications using the Android Intent mechanism.
• IP Output Plug-in – The IP Output Plug-in collects and sends data received from the Input Plug-ins to a
host computer via a network connection. Captured data can be sent over an IP network to a specified IP
address and port using either TCP or UDP transport protocols.
Profiles Screen
To launch DataWedge, swipe up from the bottom of the screen and touch . By default, the following profiles
appear:
• Profile0
• Launcher
• DWDemo
Profile0 is the default profile and is used when no other profile can be applied.
93
DataWedge
Profile names are color coded. Enabled profiles are white and disabled profiles are gray.
The profile context menu allows the profile to be edited (same as just tapping on a profile), renamed or deleted.
Options Menu
94
DataWedge
The menu provides options to create a new profile, access to general DataWedge settings and DataWedge
version information.
Disabling DataWedge
2. Touch .
3. Touch Settings.
4. Touch DataWedge enabled.
The blue check disappears from the checkbox indicating that DataWedge is disabled.
2. Touch .
5. Touch OK.
Profile Configuration
To configure the Profile0 or a user-created profile, touch the profile name.
95
DataWedge
Associating Applications
Use Applications option to associate applications with this profile. User created profiles should be associated
with one or more applications and its activities.
1. Touch Associated apps. A list of applications/activities associated with the profile displays. Initially the list
does not contain any applications/activities.
96
DataWedge
2. Touch .
4. In the Select application screen, select the desired application from the list.
5. In the Select activity menu, selecting the activity adds that application/activity combination to the
associated application list for that profile. Selecting * as the activity results in all activities within that
application being associated to the profile. During operation, DataWedge tries to match the specific
application/activity combinations with the foreground application/activity before trying to match the general
application/* combinations.
6. Touch .
97
DataWedge
Data Capture Plus (DCP) is a DataWedge feature that enables the user to initiate data capture by touching a
designated part of the screen. A variable screen overlay acts like a scan button.
DCP Button
The DataWedge profile configuration screen allows the user to configure how the DCP appears on the screen
once the particular profile is enabled. The DCP is hidden by default. Enabling DCP option displays seven
additional configuration parameters.
98
DataWedge
NOTE: The DCP does not appear if the scanner is disabled in the profile even though the Enabled option is set.
In Button mode, the user can place DCP in full screen mode by dragging the button over Fullscreen mode.
The overlay covers the screen.
99
DataWedge
Barcode Input
Use the Barcode Input options to configure the Barcode Scanner Input Plug-in for the profile.
Enabled
Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is enabled.
Scanner Selection
Configures which scanning device to use for barcode data capture when the profile is active. For Bluetooth
scanners, if the device was not previously paired, a pairing barcode displays prior to automatic connection.
• Auto (2D Barcode Imager) - The software automatically determines the best scanning device.
• Camera Scanner - Scanning is performed with the rear-facing camera.
• 2D Barcode Imager - Scanning is performed using the 2D Imager.
• Bluetooth Scanner - Scanning is performed using the optional Bluetooth scanner.
• RS6000 Bluetooth Scanner - Scanning is performed using the RS6000 Bluetooth scanner.
• DS3678 Bluetooth Scanner - Scanning is performed using the DS3678 Bluetooth scanner.
• LI3678 Bluetooth Scanner - Scanning is performed using the DS3678 Bluetooth scanner.
• DS2278 Bluetooth Scanner - Scanning is performed using the DS2278 Bluetooth scanner.
• DS8178 Bluetooth Scanner - Scanning is performed using the DS8178 Bluetooth scanner.
100
DataWedge
include those connecting by Bluetooth, serial cable or snap-on module. Disabled by default. This is only
available when Scanner Selection is set to Auto.
This helps reduce scanning workflow interruptions when a Bluetooth scanner is introduced and/or it becomes
disconnected due to losing power or moving out of range.
• Disabled - No scanner switching occurs when an external scanner is connected or disconnected (default).
• On connect - Selects the external scanner as the default scanning device immediately upon connection.
• On disconnect - Reverts to a built-in scanner based on its position in an internally managed scanner list
(which varies by host device). This is usually the scanner most recently used prior to the external
connection (see notes below).
• On connect/disconnect - Selects an external scanner as the default scanning device immediately upon
connection. Upon disconnection, reverts to the scanner set as the default prior to the external connection.
NOTE: The system selects the default scanner based on the connection state and the scanner's position in an internally
managed scanner list. If the newly connected scanner is lower in the scanner list than the one currently selected as the de-
fault scanner, the newly connected scanner becomes the default scanner.
On devices with only one built-in scanner or imager, On disconnect reverts to that built-in scanner or imager.
Decoders
Configures which barcode decoders are enabled or disabled. For best performance disable all unnecessary
decoders.
Touch Decoders. The Barcode input screen appears. A check in the checkbox indicates that the decoder is
enabled. By default the most commonly used decoders are enabled (shown below with an asterisk). The
supported decoders are:
NOTE: DataWedge supports the decoders listed below but not all are validated on this device.
101
DataWedge
Internal Imager
Internal Imager
RS507/RS507X
Camera
RS6000
DS2278
DS3678
DS8178
SE4770
LI3678
SE965
Decoders
Australian O -- O O O O O O -- O
Postal
Aztec X -- X X X X X X -- X
Canadian O -- O O -- O -- -- -- --
Postal
Chinese 2 of 5 O O O O O O O O O O
Codabar X X X X X X X X X X
Code 11 O O O O O O O O O O
Code 128 X X X X X X X X X X
Code 39 X X X X X X X X X X
Code 93 O O O O O O O O O O
Composite AB O -- O O O O O O -- O
Composite C O -- O O O O O O -- O
Discrete 2 of 5 O O O O O O O O O O
Datamatrix X -- X X X X X X -- X
Dutch Postal O -- O O O O O O -- O
DotCode X O X O O O O O O O
EAN13 X X X X X X X X X X
EAN8 X X X X X X X X X X
Grid Matrix O O O O O O O O O O
GS1 DataBar X X X X X X X X X X
GS1 DataBar X X X X X X X X X X
Expanded
GS1 DataBar O O O O O O O O O O
Limited
GS1 O -- O O -- O O O -- O
Datamatrix
GS1 QRCode O -- O O -- O O O -- O
HAN XIN O -- O O -- O O O -- O
Interleaved 2 O O O O O O O O O O
of 5
102
DataWedge
Internal Imager
Internal Imager
RS507/RS507X
Camera
RS6000
DS2278
DS3678
DS8178
SE4770
LI3678
SE965
Decoders
Japanese O -- O O O O O O -- O
Postal
Korean 3 of 5 O O O O O O O O O O
MAIL MARK X -- X X -- X X X -- X
Matrix 2 of 5 O O O O O O O O O O
Maxicode X -- X X X X X X -- X
MicroPDF O -- O O O O O O -- O
MicroQR O -- O O O O O O -- O
MSI O O O O O O O O O O
PDF417 X -- X X X X X X -- X
QR Code X -- X X X X X X -- X
Decoder O -- O O O O O -- -- --
Signature
TLC 39 O O O O O O O O O O
Trioptic 39 O O O O O O O O O O
UK Postal O -- O O O O O O -- O
UPCA X X X X X X X X X X
UPCE0 X X X X X X X X X X
UPCE1 O O O O O O O O O O
US4state O -- O O O O O O -- O
US4state FICS O -- O O O O O O -- O
US Planet O -- O O O O O O -- O
US Postnet O -- O O O O O O -- O
Key
X = Enabled
O = Disabled
-- = Not Supported
Decoder Params
Use Decode Params to configure individual decoder parameters.
103
DataWedge
NOTE: Not all parameter options are available with all scanners. See the DataWedge app on each device for the available
scanners and parameter options.
Codabar
• CLSI Editing - Enable this parameter to strip the start and stop characters and insert a space after the first,
fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires
this data format (default - disabled).
• Length1 - Use to set decode lengths (default - 6). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 55). See Decode Lengths for more information.
• NOTIS Editing - Enable this parameter to strip the start and stop characters from a decoded Codabar
symbol. Enable this feature if the host system requires this data format (default - disabled).
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Code 11
• Length1 - Use to set decode lengths (default - 4). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 55). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
• Report Check Digit - Transmit Code 11 data with or without the check digit. A check in the checkbox
indicates to send Code 11 data with check digit (default - disabled).
• Verify Check Digit - Check the integrity of all Code 11 symbols to verify that the data complies with the
specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 barcode.
• No Check Digit - Do not verify check digit.
• 1 Check Digit - Barcode contains one check digit (default).
• 2 Check Digits - Barcode contains two check digits.
Code128
• Code128 Reduced Quiet Zone - Enables decoding of margin-less Code 128 barcodes (default - disabled).
• Ignore Code128 FCN4 - When enabled, and a Code 128 barcode has an embedded FNC4 character, it will
be removed from the data and the following characters will not be changed. When the feature is disabled,
the FNC4 character will not be transmitted but the following character will have 128 added to it (default -
disabled).
• Check ISBT Table - The ISBT specification includes a table that lists several types of ISBT barcodes that
are commonly used in pairs. If ISBT128 Concat Mode is set, enable Check ISBT Table to concatenate only
those pairs found in this table. Other types of ISBT codes are not concatenated. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
• Enable GS1-128 - Set the GS1 128 subtype. A check in the checkbox indicates that the option is enabled
(default - enabled).
• Enable ISBT128 - Set the ISBT128 subtype. A check in the checkbox indicates that the option is enabled
(default - enabled).
• Enable Plain Code128 - Set the Plain Code128 subtype. Enables other (non-EAN or ISBT) Code 128
subtypes. A check in the checkbox indicates that the option is enabled (default - enabled).
104
DataWedge
• ISBT128 Concatenation Mode - Select an option for concatenating pairs of ISBT code types:
• Concat Mode Never - Do not concatenate pairs of ISBT codes encountered (default).
• Concat Mode Always - There must be two ISBT codes in order to decode and perform concatenation.
Does not decode single ISBT symbols.
• Concat Mode Auto - Decodes and concatenates pairs of ISBT codes immediately. If only a single ISBT
symbol is present, the device must decode the symbol the number of times set via DataWedge
Configuration 4 - 11 Redundancy - Code128 before transmitting its data to confirm that there is no
additional ISBT symbol.
• Length1 - Use to set decode lengths (default - 0). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 55). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
• Security Level - The scanner offers four levels of decode security for Code 128 barcodes. Select
increasing levels of security for decreasing levels of barcode quality. There is an inverse relationship
between security and scanner aggressiveness, so choose only that level of security necessary for any
given application.
• Security Level 0 - This setting allows the scanner to operate in its most aggressive state, while
providing sufficient security in decoding most “in-spec” barcodes.
• Security Level 1 - This setting eliminates most misdecodes (default).
• Security Level 2 - Select this option if Security level 1 fails to eliminate misdecodes.
• Security Level 3 - If Security Level 2 is selected and misdecodes still occur, select this security level.
Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec
barcodes. Selecting this level of security significantly impairs the decoding ability of the scanner. If this
level of security is needed, try to improve the quality of the barcodes.
Code39
• Code39 Reduced Quiet Zone - Enables decoding of margin-less Code 39 barcodes (default - disabled).
• Convert Code39 To Code32 - Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry.
Scan the appropriate barcode below to enable or disable converting Code 39 to Code 32 (default -
disabled).
• Full ASCII- Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII
character set. To enable or disable Code 39 Full ASCII (default - disabled),
• Length1 - Use to set decode lengths (default - 0). See Decode Lengths for more information.
• Length2 - Use to set decode lengths 4 (default - 55). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
• Report Check Digit - Transmit Code 39 data with or without the check digit. A check in the checkbox
indicates to send Code 39 data with check digit (default - disabled).
• Report Code32 Prefix - Scan the appropriate barcode to enable or disable adding the prefix character “A”
to all Code 32 barcodes (default - disabled).
105
DataWedge
• Security Level - Options: Security level 0, Security Level 1, Security Level 2 and Security Level 3
(default - Security level 1).
• Security Level 0 - This setting allows the scanner to operate in its most aggressive state, while
providing sufficient security in decoding most “in-spec” barcodes.
• Security Level 1 - This setting eliminates most misdecodes (default).
• Security Level 2 - Select this option if Security level 1 fails to eliminate misdecodes.
• Security Level 3 - If Security Level 2 is selected and misdecodes still occur, select this security level.
Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec
barcodes. Selecting this level of security significantly impairs the decoding ability of the scanner. If this
level of security is needed, try to improve the quality of the barcodes.
• Verify Check Digit - Enable this feature to check the integrity of all Code 39 symbols to verify that the data
complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols
that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43
check digit (default - disabled).
Code93
• Length1 - Use to set decode lengths (default - 0). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 55). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
Composite AB
• UCC Link Mode
• Link Flag ignored - 1D component is transmitted regardless of whether a 2D component is detected.
• Always Linked - 1D and the 2D components are transmitted. If 2D is not present, the 1D component is
not transmitted.
• Auto Discriminate - the digital scanner determines if there is a 2D portion, then transmits the 1D
component, as well as the 2D portion if present. (default).
Discrete 2 of 5
• Length1 - Use to set decode lengths (default - 0). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 14). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
DotCode
• Inverse - Specify the reflectance for decoding DotCode barcodes.
• Disabled (0) - Decode DotCode barcodes with normal reflectance only.
• Enabled (1) - Decode DotCode barcodes with inverse reflectance only.
• Auto (2) - Decodes both normal and inverse reflectance DotCode barcodes. (default - enabled).
• Mirror - Specify whether mirrored DotCode barcodes are decoded.
• Disabled (0) - Decode non-mirrored DotCode barcodes only.
• Enabled (1) - Decode mirrored DotCode barcodes only.
• Auto (2) - Decodes both mirrored and non-mirrored DotCode barcodes. (default - enabled).
106
DataWedge
HAN XIN
• HAN XIN Inverse
• Disable - Disables decoding of HAN XIN inverse barcodes (default).
• Enable - Enables decoding of HAN XIN inverse barcodes.
• Auto - Decodes both HAN XIN regular and inverse barcodes.
Interleaved 2 of 5
• Check Digit
• No Check Digit - A check digit is not used. (default)
• USS Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Uniform Symbology Specification (USS) check digit algorithm.
• OPCC Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Optical Product Code Council (OPCC) check digit algorithm.
• Length1 - Use to set decode lengths (default - 14). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 10). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
• Report Check Digit - Transmit Interleaved 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send Interleaved 2 of 5 data with check digit (default - disabled).
• I2of5 Security Level - Options: I2of5 Security level 0, I2of5 Security Level 1, I2of5 Security Level 2
and I2of5 Security Level 3 (default - I2of5 Security level 1).
• Convert ITF-14 To EAN13 - Convert 14-character Interleaved 2 of 5 barcodes to EAN-13, and transmit as
EAN-13. The Interleaved 2 of 5 barcode must be enabled and must have a leading zero and a valid EAN-13
check digit. A check in the checkbox indicates that the option is enabled (default - disabled).
• I2of5 Reduced Quiet Zone - Enables decoding of margin-less I2of5 barcodes (default - disabled).
Matrix 2 of 5
• Length1 - Use to set decode lengths (default - 10). See Decode Lengths for more information.
• Length2 - Use to set decode lengths (default - 0). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
• Report Check Digit - Transmit Matrix 2 of 5 data with or without the check digit. A check in the checkbox
indicates to send Matrix 2 of 5 data with check digit (default - enabled).
• Verify Check Digit - Enable this feature to check the integrity of all Matrix 2 of 5 symbols to verify that the
data complies with a specified check digit algorithm (default - enabled).
107
DataWedge
MSI
• Check Digit - With MSI symbols, one check digit is mandatory and always verified by the reader. The
second check digit is optional.
• One Check Digit - Verify one check digit (default).
• Two Check Digits - Verify two check digits.
• Check Digit Scheme - Two algorithms are possible for the verification of the second MSI check digit.
Select the algorithm used to encode the check digit.
• Mod-11-10 - First check digit is MOD 11 and second check digit is MOD 10 (default).
• Mod-10-10 - Both check digits are MOD 10.
• Length 1 - Use to set decode lengths (default - 4). See Decode Lengths for more information.
• Length 2 - Use to set decode lengths (default - 55). See Decode Lengths for more information.
• Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
• Report Check Digit - Transmit MSI data with or without the check digit. A check in the checkbox indicates
to send MSI data with check digit (default - disabled).
Trioptic 39
• Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
UK Postal
• Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the checkbox
indicates to send UK Postal data with check digit (default - disabled).
UPCA
• Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCA preamble:
• Preamble None - Transmit no preamble.
• Preamble Sys Char - Transmit System Character only (default).
• Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA). Select
the appropriate option to match the host system.
• Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
enabled).
UPCE0
• Convert UPCE0 To UPCA - Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A format
before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A
programming selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without conversion
(default - disabled).
108
DataWedge
• Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE0 preamble:
• Preamble None - Transmit no preamble (default).
• Preamble Sys Char - Transmit System Character only.
• Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
• Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
UPCE1
• Convert UPCE1 To UPCA - Enable this to convert UPCE1 decoded data to UPC-A format before
transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion (default -
disabled).
• Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE1 preamble:
• Preamble None - Transmit no preamble (default).
• Preamble Sys Char - Transmit System Character only.
• Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
• Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
US Planet
• Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
Decode Lengths
The allowable decode lengths are specified by options Length1 and Length2 as follows:
• Variable length: Decode symbols containing any number of characters.
• Set both Length1 and Length2 to 0.
• Range: Decode a symbol with a specific length range (from a to b, including a and b).
• Set Length1 to a and set Length2 to b.
• Two Discrete Lengths: Decode only symbols containing either of two selected lengths.
• Set both Length1 or Length2 to the specific lengths. Length1 must be greater than Length2.
• One Discrete Length: Decode only symbols containing a specific length.
• Set both Length1 and Length2 to the specific length.
NOTE: Not all parameter options are available with all scanners. See the DataWedge app on each device for the available
scanners and parameter options.
109
DataWedge
• Convert DataBar To UPC EAN - If this is set it converts DataBar barcodes to UPC/EAN format. For this
setting to work UPC/EAN symbologies must be enabled. A check in the checkbox indicates that the option
is enabled. (default - disabled).
• UPC Reduced Quiet Zone - Enables decoding of margin-less UPC barcodes. (default - disabled)
• Bookland - Enable Bookland decoding. A check in the checkbox indicates that the option is enabled.
(default - disabled).
• Bookland Format - If Bookland EAN is enabled, select one of the following formats for Bookland data:
• Format ISBN-10 - The decoder reports Bookland data starting with 978 in traditional 10-digit format with
the special Bookland check digit for backward-compatibility. Data starting with 979 is not considered
Bookland in this mode. (default)
• Format ISBN-13 - The decoder reports Bookland data (starting with either 978 or 979) as EAN-13 in
13-digit format to meet the 2007 ISBN-13 protocol.
• Coupon - Enables Coupon code decoding. Note that in order to successfully decode Coupon codes, all of
the correct decoders must be enabled. A check in the checkbox indicates that the option is enabled.
(default - disabled).
• Coupon Report Mode - Traditional coupon symbols are composed of two barcode: UPC/EAN and Code
128. A new coupon symbol is composed of a single Data Expanded barcode. The new format offers more
options for purchase values (up to $999.999) and supports complex discount offers as a second purchase
requirement. An interim coupon symbol also exists that contain both types of barcodes: UPC/EAN and
Databar Expanded. This format accommodates both retailers that do not recognize or use the additional
information included in the new coupon symbol, as well as those who can process new coupon symbols.
• Old Coupon Report Mode - Scanning an old coupon symbol reports both UPC and Code 128,
scanning is interim coupon symbol reports UPC, and scanning a new coupon symbol reports nothing
(no decode).
• New Coupon Report Mode - Scanning an old coupon symbol reports either UPC or Code 128, and
scanning an interim coupon symbol or a new coupon symbol reports Databar Expanded.
• Both Coupon Report Modes - Scanning an old coupon symbol reports both UPC and Code 128, and
scanning an interim coupon symbol or a new coupon symbol reports Databar Expanded. (default)
• Ean Zero Extend – Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make
them compatible in format to EAN-13 symbols. Disable this to transmit EAN-8 symbols as is. Default –
disabled.
• Linear Decode - This option applies to code types containing two adjacent blocks, for example, UPC-A,
EAN-8, EAN-13. Enable this parameter to transmit a bar code only when both the left and right blocks are
successfully decoded within one laser scan. Enable this option when bar codes are in proximity to each
other (default - enabled).
• Retry Count - Retry count for auto-discriminating for supplementals. Possible values are 2 to 20 inclusive.
Note that this flag is only considered if Supplemental Mode - UPC EAN is set to one of the following values:
Supplementals Auto, Supplementals Smart, Supplementals 378-379, Supplementals 978-979,
Supplementals 977 or Supplementals 414-419-434-439 (2 to 20, default 10).
110
DataWedge
• Security Level - The scanner offers four levels of decode security for UPC/EAN barcodes. Select higher
security levels for lower quality barcodes. There is an inverse relationship between security and decode
speed, so be sure to choose only that level of security necessary for the application.
• Level 0 - This default setting allows the scanner to operate fastest, while providing sufficient security in
decoding “in-spec” UPC/EAN barcodes.
• Level 1 - As barcode quality levels diminish, certain characters become prone to misdecodes before
others (i.e., 1, 2, 7, 8). If the scanner is misdecoding poorly printed barcodes, and the misdecodes are
limited to these characters, select this security level. (default).
• Level 2 - If the scanner is misdecoding poorly printed barcodes, and the misdecodes are not limited to
characters 1, 2, 7, and 8, select this security level.
• Level 3 - If the scanner is still misdecoding, select this security level. Be advised, selecting this option is
an extreme measure against misdecoding severely out of spec barcodes. Selecting this level of security
can significantly impair the decoding ability of the scanner. If this level of security is necessary, try to
improve the quality of the barcodes.
• Supplemental2 - Enables or disables this option. A check in the checkbox indicates that the option is
enabled.
• Supplemental5 - Enables or disables this option. A check in the checkbox indicates that the option is
enabled.
• Supplemental Mode
• No Supplementals - the scanner is presented with a UPC/EAN plus supplemental symbol, the scanner
decodes UPC/EAN and ignores the supplemental characters (default).
• Supplemental Always - the scanner only decodes UPC/EAN symbols with supplemental characters,
and ignores symbols without supplementals.
• Supplements Auto - the scanner decodes UPC/EAN symbols with supplemental characters
immediately. If the symbol does not have a supplemental, the scanner must decode the barcode the
number of times set via UPC/EAN Supplemental Redundancy before transmitting its data to confirm that
there is no supplemental.
• Supplemental Smart - Enables smart supplementals. In this mode the decoder returns the decoded
value of the main block right away if it does not belong to one of the following supplemental types: 378,
379, 977, 978, 979, 414, 419, 434 or 439. If the barcode starts with one of the prefixes it searches the
image more aggressively for a supplemental. Tries to scan the supplemental if it is present. If the
supplemental scanning failed, then the main barcode is returned.
• Supplemental 378-379 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with
378 or 379. Disables reading of supplementals for any other UPC/EAN barcode not starting with 378 or
379. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main
barcode is returned.
• Supplemental 978-979 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with
978 or 979. Disables reading of supplementals for another UPC/EAN barcode not starting with 978 or
979. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main
barcode is returned.
• Supplemental 414-419-434-439 - Enables (auto-discriminate) supplemental for UPC/EAN codes
starting with 414, 419, 434 or 439. Disables reading of supplementals for another UPC/EAN barcode 4 -
16 not starting with 414, 419, 434 or 439. Tries to scan the supplemental if it is present. If the
supplemental scanning failed, then the main barcode is returned.
• Supplemental 977 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with 977.
Disables reading of supplementals for another UPC/EAN barcode not starting with 977. Tries to scan
the supplemental if it is present. If the supplemental scanning failed, then the main barcode is returned.
111
DataWedge
Reader Params
Allows the configuration of parameters specific to the selected barcode reader.
NOTE: Not all parameter options are available with all scanners. See the DataWedge app on each device for the available
scanners and parameter options.
• Character Set Configuration - Used to support the GB2312 Chinese characters encoding.
• Character Set Selection - Allows the user to convert the barcode data if different from default encoding
type.
• Auto Character Set Selection (Best Effort) - Automatic character convert option. Tries to decode
data from the Preferred selection. The first correct decodable character set is used to convert the
data and is sent.
• ISO-8859-1 - Part of the ISO/IEC 8859 series of ASCII-based standard character encodings. It is
generally intended for Western European languages.
• Shift_JIS - Shift Japanese Industrial Standards (JIS) is a character encoding for the Japanese
language.
• GB18030 - Chinese coded character set that defines the required language and character support
necessary for software in China.
• UTF-8 - A character encoding capable of encoding all possible characters, or code points, defined by
Unicode (default).
• Auto Character Set Preferred Order - In Auto Character Set Selection mode, the system will try to
decode the data in a preference order of character sets. The algorithm used is a best effort one. That is,
there could be cases where the data can be decoded from more than one character set. The first
character set from the preferred list which can decode the data successfully will be chosen to decode
the data and sent to the user. Any other character set that is in the list but lower in the preferred order,
would not be considered, even if the data could be successfully decoded using such character set.
The preferred character set and its preference order is configurable to the user through the Auto
Character Set Preferred Order menu. Users can change the order by dragging the icon for that menu
item. To delete an item, long press on an item and the Delete option will appear. To add a new item, tap
the menu icon at top right corner and options to add UTF-8 and GB2312 will appear.
• UTF-8 - A character encoding capable of encoding all possible characters, or code points, defined by
Unicode (default).
• GB2312 - Character set of the People's Republic of China, used for simplified Chinese characters.
• Auto Character Set Failure Option - If the system cannot find a character set from the preferred list
that can be used to successfully decode the data, the character set selected in Auto Character Set
Failure Option is used to decode the data and send to the user. If NONE is used, Null data is returned
as string data.
• NONE
• UTF-8 - A character encoding capable of encoding all possible characters, or code points, defined by
Unicode (default).
• ISO-8859-1 - Part of the ISO/IEC 8859 series of ASCII-based standard character encodings. It is
generally intended for Western European languages.
• Shift_JIS - Shift Japanese Industrial Standards (JIS) is a character encoding for the Japanese
language.
• GB18030 - Chinese coded character set that defines the required language and character support
necessary for software in China.
• 1D Quiet Zone Level - Sets the level of aggressiveness in decoding barcodes with a reduced quiet zone
(the area in front of and at the end of a barcode), and applies to symbologies enabled by a Reduced Quiet
Zone parameter. Because higher levels increase the decoding time and risk of misdecodes, Zebra strongly
112
DataWedge
recommends enabling only the symbologies which require higher quiet zone levels, and leaving Reduced
Quiet Zone disabled for all other symbologies.
Options are:
• 0 - The scanner performs normally in terms of quiet zone.
• 1 - The scanner performs more aggressively in terms of quiet zone (default).
• 2 - The scanner only requires one side EB (end of barcode) for decoding.
• 3 - The scanner decodes anything in terms of quiet zone or end of barcode.
• Adaptive Scanning - When adaptive scanning is enabled, the scan engine toggles between wide and
narrow, allowing the scan engine to decode barcodes based on the distance.
• Disable
• Enable (default).
• Beam Width - Beam Width is applicable only with linear scanners.
• Narrow
• Normal (default)
• Wide
• Aim mode - Turns the scanner cross-hairs on or off.
• On - Cross-hair is on (default).
• Off - Cross-hair is off.
• Aim Timer - Sets the maximum amount of time that aiming remains on (0 - 60,000 ms in increments of 100
ms). A value of 0 sets the aim to stay on indefinitely (default - 500).
• Aim Type - Set the aiming usage.
• Trigger - A trigger event activates decode processing, which continues until the trigger event ends or a
valid decode occurs (default).
• Timed Hold - A trigger pull and hold activates the laser for aiming, which continues until the trigger is
released, a valid decode, or the decode session time-out is expired.
• Timed Release - A trigger pull activates the laser for aiming, which continues until a valid decode or the
remaining decode session time has expired.
• Press and Release - A trigger pull and release activates the laser for aiming, which continues until a
trigger is pressed again, a valid decode, or the decode session time-out is expired.
• Presentation - Automatically activates the scanner and starts scanning immediately when a barcode is
presented in its field of view, without any trigger press. (Only supported on SE4750SR.)
• Continuous Read - A trigger pull activates a decode session which continues until the Beam Timer
expires or the trigger is released. Barcodes are continuously decoded while the session is active.
• Press and Sustain - A trigger pull activates decode processing which continues until the Beam Timer
expires or a barcode is decoded.
• Beam Timer - Sets the maximum amount of time that the reader remains on (0 - 60,000 ms in increments
of 100 ms). A value of 0 sets the reader to stay on indefinitely (default -5000).
• Time Delay to Low Power - Sets the time the decoder remains active after decoding. After a scan session,
the decoder waits this amount of time before entering Low Power Mode. Options: 1 Second (default), 30
Seconds, 1 Minute or 5 Minutes.
• Different Symbol Timeout - Controls the time the scanner is inactive between decoding different symbols.
Programmable in 500 msec increments from 0 to 5 seconds. The default is 500 msec.
113
DataWedge
114
DataWedge
• Picklist - Allows the imager to decode only the barcode that is directly under the cross-hair/reticle (+) part
of the pattern. This feature is useful in applications where multiple barcodes may appear in the field of view
during a decode session and only one of them is targeted for decode.
• Disabled – Disables Picklist mode. Any barcode within the field of view can be decoded (default).
• Enabled – Enables Picklist mode so that only the barcode under the projected reticle can be decoded.
• Poor Quality Decode Effort - Enable poor quality barcode decoding enhancement feature.
• Same Symbol Timeout - Controls the time the scanner is inactive between decoding same symbols.
Programmable in 500 msec increments from 0 to 5 seconds. The default is 500 msec.
• Scanning Modes - Scanning options available on the device.
• Single - Set to scan general barcodes (default).
• UDI - Set to scan healthcare specific barcodes.
• MultiBarcode - Set to scan multiple barcodes. When this option is selected, the Multibarcode params
can be set to read from 2 to 10 barcodes on a single scan.
Scan Params
Allows the configuration of Code ID and decode feedback options.
NOTE: Not all parameter options are available with all scanners. See the DataWedge app on each device for the available
scanners and parameter options.
• Code ID Type - A Code ID character identifies the code type of a scanned barcode. This is useful when the
reader is decoding more than one code type. Select a code ID character to insert between the prefix and
the decoded symbol.
• Code ID Type None - No prefix (default)
• Code ID Type AIM - Insert AIM Character prefix.
• Code ID Type Symbol - Insert Symbol character prefix.
• Engine Decode LED - Use to turn on scanner red LED when the scan beam is emitting either by scanner
trigger or using soft scan button.
• BT Disconnect On Exit - Bluetooth connection is disconnected when data capture application is closed .
• Connection Idle Time - Set connection idle time. The Bluetooth connection disconnects after being idle for
set time.
• Display BT Address Barcode - Enable or disable displaying Bluetooth Address bar code if there is no
Bluetooth scanner being paired when application tries to enable the Bluetooth scanner.
• Establish Connection Time - The timeout which the device will try to enable or reconnect to the Bluetooth
scanner when the Bluetooth scanner is not in the vicinity or not paired.
• Audio Feedback Mode - Select good decode audio indication.
• Local Audio Feedback - Good decode audio indication on device only.
• Remote Audio Feedback - Good decode audio indication.
• Both - Good decode audio indication on device and scanner (default).
• Disable - No good decode audio indication on either device or scanner.
• LED Feedback Mode - Select good decode LED indication.
• Local LED Feedback - Good decode LED indication on device only.
• Remote LED Feedback - Good decode LED indication on scanner.
• Both - Good decode LED indication on device and scanner (default).
• Disable - No good decode LED indication on either device or scanner.
• Decode Audio Feedback - Select an audio tone to sound upon a good decode (default optimized-beep).
115
DataWedge
• Decoding LED Notification - Enable the device to light the red Data Capture LED when data capture is in
progress. (default - disabled).
• Decode Feedback LED Timer - Set the amount of time (in milliseconds) that the green Data Capture LED
stays lit after a good decode. (default - 75 msec.)
• Beep Volume Control - Set the good decode beep to a system or other sound. This allows for independent
control of the good beep volume.
NOTE: Not all ringtones are fully supported as decode tones and those of longer length may be truncated when used as a
decode tone. The recommendation is to test the selected tone for operation before deployment to a customer site.
UDI Params
Allows the configuration of parameters specific to healthcare barcodes.
• Enable UDI-GSI - Enable UDI using GS1 standards (default - enabled).
• Enable UDI-HIBCC - Enable UDI using HIBCC standards (default - enabled).
• Enable UDI-ICCBBA - Enable UDI using ICCBBA standards (default - enabled).
Multibarcode params
Set the number of barcodes that the device can read on a single scan from 2 to 10. Must also enable Reader
Params > Scanning Modes > MultiBarcode option.
Voice Input
Zebra GMS devices have a built in Google speech recognition engine. By making use of the speech engine
capabilities, DataWedge has extended automated data capturing to user applications through voice. Currently,
DataWedge does not capture data for Voice Input.
Voice data capturing starts after you speak the predefined start phrase and it stops after you speak the data or
speak the end phrase, if one was defined.
IMPORTANT:
• Simultaneous use of Voice Input in DataWedge and Google Voice is not supported.
• Voice Input is not supported if the Enterprise Home Screen (EHS) is in restricted mode. However, enabling all of the
privilege settings in EHS reinstates Voice Input.
• Voice Input is not supported if the device language is changed to another language, for example Chinese.
116
DataWedge
• Data capture start phrase - Starts data capture with the phrase entered in this field.This field is
mandatory. (Default - start).
Providing numbers and other special characters as the data capture start phrase is not supported.
• Data capture end phrase - Ends data capture with the phrase entered in this field or keep it blank if not
required. This field is not mandatory. (Default - Blank).
• Tab command - Enables the Tab command, which sends a tab key when the user speaks the command
send tab. The commands are supported only when the device is at the Waiting for start phrase state.
• Enter command - Enables the Enter command, which sends an enter key when the user speaks the
command send enter. The commands are supported only when the device is at the Waiting for start
phrase state.
• Data type - Allows the user to configure the data type. Set the data type to limit the data capture according
to the preferences specified. Available options:
• Any - Scanning a barcode of ABC123, returns ABC123.
• Alpha - Scanning a barcode of ABC123, returns ABC only.
• Numeric - Scanning a barcode of ABC, returns 123 only.
• Start phrase waiting tone - Enables or disables this option. Enables audio feedback for Waiting for
start. This option notifies the user that the device is waiting to start the speech engine if you miss the toast
message and the Waiting for start state changes.
• Data capture waiting tone - Enables or disables this option. Enables audio feedback for Waiting for
data. This option notifies the user that the device is waiting to capture data if you miss the toast message.
• Validation window - Enables or disables the Validate captured data window. Enable this option to
validate the result that you speak. The window displays the data spoken and the data can be edited on the
same screen if any modification is needed. This is very useful when used with the offline mode, since the
results receive at this moment might not be accurate.
• Offline speech recognition - Enables or disables speech recognition. Enable this option to use Voice
Input when you do not have access to the Internet. This option uses an offline recognition speech engine to
detect the data you speak.
Keystroke Output
117
DataWedge
• Key event delay - Set the amount of time (in milliseconds) of the wait time for control characters. (default -
0.)
• Data formatting and ordering - Allows formatting and ordering of UDI and Multibarcode data.
• UDI specific - Allows the output order of acquired UDI data to be adjusted and the optional insertion of
a tab, line feed, or carriage return character between tokens.
• Send tokens - Set to select the output format for UDI data. (default - disabled)
• Token separator - Set to select a separator character. If no separator character is selected when
Send tokens is set to Barcodes and tokens, two instances of the same data are sent. (default - none)
• Token order - Set to include or exclude Tokens from the output and adjust their output order.
• Multibarcode specific - Allows the optional insertion of a tab, line feed, or carriage return between each
barcode.
• Barcode separator - Set to select a separator character. If no separator character is selected, the
data set is sent as a single string.
• Advanced data formatting - is a way to customizing data before transmission. Use advanced data
formatting (ADF) to edit scan data to suit requirements.
• Enable - Enables or disables ADF. A check in the checkbox indicates that ADF is enabled (default -
disabled).
• Rules - ADF uses rules to customize data. These rules perform detailed actions when the data meets
certain criteria. One rule may consist of single or multiple criteria applied to single or multiple actions.
See Generating Advanced Data Formatting Rules for more information.
• Basic data formatting - Allows the configuration of any data formatting for the related Output Plug-in.
When the plug-in is disabled, any data is passed on without modification.
• Enabled - Enables or disables Basic Data Formatting. A check in the checkbox indicates that it is
enabled (default - enabled).
• Prefix to data - Add characters to the beginning of the data when sent.
• Suffix to data - Add characters to the end of the data when sent.
• Send data - Set to transfer the captured data to the foreground application. Disabling this option
prevents the actual data from being transmitted. However, the prefix and suffix strings, if present, are
still transmitted even when this option is disabled (default - enabled).
• Send as hex - Set to send the data in hexadecimal format. A check in the checkbox indicates that the
plug-in is enabled (default - disabled).
• Send TAB key - Set to append a tab character to the end of the processed data. A check in the
checkbox indicates that the plug-in is enabled (default - disabled).
• Send ENTER key - Set to append an Enter character to the end of the processed data. A check in the
checkbox indicates that the plug-in is enabled (default - disabled).
Intent Output
Allows configuration of the Intent Output Plug-in for the profile. The Intent Output Plug-in allows the captured
data to be sent to an application in the form of an implicit Intent. Refer to the Android Developer web site for
more information, developer.android.com.
• Enabled - Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is enabled
(default - disabled).
• Intent action - Enter the Intent Action name (required).
• Intent category - Enter the Intent Category name (required).
118
DataWedge
Intent Overview
The core components of an Android application (its activities, services, and broadcast receivers) are activated
by intents. An intent is a bundle of information (an Intent object) describing a desired action - including the data
to be acted upon, the category of component that should perform the action, and other pertinent instructions.
Android locates an appropriate component to respond to the intent, launches a new instance of the component
if one is needed, and passes it the Intent object.
Components advertise their capabilities, the kinds of intents they can respond to, through intent filters. Since
the system must learn which intents a component can handle before it launches the component, intent filters
are specified in the manifest as <intent-filter>elements. A component may have any number of filters, each one
describing a different capability. For example, if the manifest contains the following:
<intent-filter . . . >
<action android:name=”android.intent.action.DEFAULT” />
<category android:name=”android.intent.category.MAIN” />
</intent-filter>
119
DataWedge
In the Intent output plug-in configuration, the Intent action would be:
android.intent.action.DEFAULT
and the Intent category would be:
android.intent.category.MAIN.
The Intent delivery option allows the method by which the intent is delivered to be specified. The delivery
mechanisms are Send via startActivity, Send via startService or Broadcast intent.
The decode related data added to the Intent’s bundle can be retrieved using the Intent.getStringExtra()
and Intent.getSerializableExtra() calls, using the following String tags:
• String LABEL_TYPE_TAG = “com.symbol.emdk.datawedge.label_type”;
• String contains the label type of the barcode.
• String DATA_STRING_TAG = “com.symbol.datawedge.data_string”;
• String contains the output data as a String. In the case of concatenated barcodes, the decode data is
concatenated and sent out as a single string.
• String DECODE_DATA_TAG = “com.symbol.datawedge.decode_data”;
• Decode data is returned as a list of byte arrays. In most cases there will be one byte array per decode.
For barcode symbologies that support concatenation, for example, Codabar, Code128, MicroPDF, etc.,
the decoded data is stored in multiple byte arrays (one byte array per barcode). Clients can get data in
each byte array by passing an index.
Most scanning applications might want the user to be able to decode data and for that decode data to be sent
to the *current* activity but not necessarily displayed. If this is the case, then the activity needs to be marked
as ‘singleTop’ in its AndroidManifest.xml file. If your activity is not defined as singleTop, then on every decode,
the system will create another copy of your Activity and send the decode data to this second copy.
Finally there will be a configuration option for each process plug-in so that the process plug-in can be
configured specifically for the intent output, which in this case is the basic data formatting process plug-in.
IP Output
NOTE: IPWedge application is required on a host computer. Download the IPWedge application from the Support Central
web site: www.zebra.com/support.
IP Output allows DataWedge to send captured data to a host computer via a network connection. Captured
data can be sent over an IP network to a specified IP address and port using either TCP or UDP transport
protocols.
• Enabled - Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is enabled
(default - disabled).
• Remote Wedge - Enable or disable the Remote Wedge option (default - enabled). Remote Wedge is used
with the IPWedge application.
• Protocol - Select the protocol used by the remote application. Options: TCP (default) or UDP.
• IP address - Enter the IP address used by the remote application (default - 0.0.0.0).
• Port - Enter the port number used by the remote application (default - 58627).
• Data formatting and ordering - Allows formatting and ordering of UDI and Multibarcode data.
• UDI specific - Allows the output order of acquired UDI data to be adjusted and the optional insertion of
a tab, line feed, or carriage return character between tokens.
• Send tokens - Set to select the output format for UDI data. (default - disabled)
120
DataWedge
• Token separator - Set to select a separator character. If no separator character is selected when
Send tokens is set to Barcodes and tokens, two instances of the same data are sent. (default - none)
• Token order - Set to include or exclude Tokens from the output and adjust their output order.
• Advanced data formatting - is a way of customizing data before transmission. Use advanced data
formatting (ADF) to edit scan data to suit requirements.
• Enable - Enables or disables ADF. A check in the checkbox indicates that ADF is enabled (default -
disabled).
• Rules - ADF uses rules to customize data. These rules perform detailed actions when the data meets
certain criteria. One rule may consist of single or multiple criteria applied to single or multiple actions.
See Generating Advanced Data Formatting Rules for more information.
• Basic data formatting - Allows configuration of any data formatting for the related Output Plug-in. When
the plug-in is disabled any data is passed on without modification.
• Enabled - Enables or disables Basic Data Formatting. A check in the checkbox indicates that it is
enabled (default - enabled).
• Prefix to data - Add characters to the beginning of the data when sent.
• Suffix to data - Add characters to the end of the data when sent.
• Send data - Set to transfer the captured data to the foreground application. Disabling this option
prevents the actual data from being transmitted. However, the prefix and suffix strings, if present, are
still transmitted even when this option is disabled (default - enabled).
• Send as hex - Set to send the data in hexadecimal format. A check in the checkbox indicates that the
plug-in is enabled (default - disabled).
• Send TAB key - Set to append a tab character to the end of the processed data. A check in the
checkbox indicates that the plug-in is enabled (default - disabled).
• Send ENTER key - Set to append an Enter character to the end of the processed data. A check in the
checkbox indicates that the plug-in is enabled (default - disabled).
Usage
This section provides information on how to configure IP Output using the DataWedge configuration user
interface. To use IP Output in a particular DataWedge profile (for example: Profile0), scroll downward on IP
Output.
121
DataWedge
5. Touch IP Address.
6. In the Enter IP Address dialog box, enter the IP address of host computer to send data to.
122
DataWedge
7. Touch Port.
8. In the Enter port number dialog box, enter same port number selected for IPWedge computer application.
9. Configure Advanced data formatting and Basic data formatting Plug-in if any required modification to be
done to captured data before sending to remote computer.
5. Touch IP Address.
123
DataWedge
6. In the Enter IP address dialog box, enter the IP address of host computer to send data to.
7. Touch Port.
8. In the Enter port number dialog box, enter the port number that the host computer application is listening
on.
9. Configure Advanced Data Formatting and Basic Data Formatting Plug-in if any required modification to
be done to captured data before sending to remote computer.
Configuring the ADF plug-in consists of creating a rule, defining the criteria and defining the actions.
124
DataWedge
Creating a Rule
NOTE: By default, Rule0, is the only rule in the Rules list.
1. Touch .
Defining a Rule
125
DataWedge
2. Touch the Rule enabled check box to enable the current rule.
Defining Criteria
1. Touch Criteria.
2. Touch String to check for option to specify the string that must be present in the data.
3. In the Enter the string to check for dialog box, enter the string
4. Touch OK.
126
DataWedge
5. Touch String position option to specify the position of the string specified in the String to check for
option. The ADF rule is only applied if the specific string in String to check for is found at the specified
String position location (zero for the start of the string).
6. Touch the + or - to change the value.
7. Touch OK.
8. Touch String length option to specify a length for the received data. The ADF rule only applies to the
barcode data with that specified length.
9. Touch the + or - to change the value.
10.Touch OK.
11.Touch Source criteria option to associate an input device to an ADF rule. The ADF rule only applies to
data received from associated input devices.
12.Touch Barcode input. Options vary depending upon the device configuration.
13.Touch the Source enabled checkbox to accept data from this source.
14.For general barcode inputs, touch the All decoders enabled checkbox to select all bar code symbologies.
Deselect the All decoders enabled checkbox to individually select the symbologies.
Defining an Action
NOTE: By default the Send remaining action is in the Actions list.
127
DataWedge
1. Touch .
6. Touch .
7. Touch .
Deleting a Rule
1. Touch and hold on a rule until the context menu appears.
2. Touch Delete rule to delete the rule from the Rules list.
NOTE: When there is no rule available for ADF plug-in or all rules are disabled, DataWedge passes decoded data to the
output plug-in without processing the data.
Rules are processed in top-down order. The rules that are on top of the list are processed first. Use the icon
next to the rule to move it to another position in the list.
128
DataWedge
Deleting an Action
1. Touch and hold the action name.
2. Select Delete action from the context menu.
ADF Example
The following illustrates an example of creating Advanced Data Formatting:
129
DataWedge
• length of 12 characters.
• contains 129 at the start position.
2. Touch Profile0.
3. Under Keystroke Output, touch Advanced data formatting.
4. Touch Enable.
5. Touch Rule0.
6. Touch Criteria.
7. Touch String to check for.
8. In the Enter the string to check for text box, enter 129 and then touch OK.
11.Touch OK.
12.Touch String length.
13.Change value to 12.
14.Touch OK.
15.Touch Source criteria.
16.Touch Barcode input.
17.Touch All decoders enabled to disable all decoders.
18.Touch Code 39.
20.Touch Actions.
21.Touch and hold on the Send remaining rule until a menu appears.
22.Touch Delete action.
23.Touch .
130
DataWedge
29.Press .
30.Touch .
36.Touch OK.
37.Touch .
38.Touch .
44.Touch OK.
45.Touch .
46.Ensure that an application is open on the device and a text field is in focus (text cursor in text field).
131
DataWedge
1299X1559828
DataWedge Settings
The DataWedge Settings screen provides access to general, non-profile related options. Touch > Settings.
132
DataWedge
• DataWedge enabled - Enables or disables DataWedge. To disable DataWedge uncheck this option
(default - enabled).
• Enable logging - Enables or disables debug output file to logcat. To enable logging check this option
(default - disabled).
• Ignore disabled profiles - Prevents DataWedge from switching to a Profile that is not enabled. In such
instances, the Profile switch is ignored and the current Profile remains active Profile0 must be disabled to
use this feature (default - disabled).
• Disable app list - Disables scanning functions for selected applications or activities.
• Import - Allows import of a DataWedge configuration file. The imported configuration replaces the current
configuration.
• Export - Allows export of the current DataWedge configuration.
• Import Profile - Allows import of a DataWedge profile file.
• Export Profile - Allows export of a DataWedge profile.
• Restore - Return the current configuration back to factory defaults.
• Reporting - Configures reporting options.
2. Touch .
3. Touch Settings.
4. Touch Import.
5. Touch filename to import.
The configuration file (datawedge.db) is imported and replaces the current configuration.
133
DataWedge
1. Touch .
2. Touch Settings.
3. Touch Export.
4. In the Export to dialog box, select the location to save the file.
5. Touch Export. The configuration file (datawedge.db) is saved to the selected location.
NOTE: Do not change the filename of the of the profile file. If the filename is changed, the file will not be imported.
2. Touch .
3. Touch Settings.
4. Touch Import Profile.
5. Touch the profile file to import.
6. Touch Import. The profile file (dwprofile_x.db, where x = the name of the profile) is imported and appears
in the profile list.
Exporting a Profile
1. Touch .
2. Touch Settings.
3. Touch Export Profile.
4. Touch the profile to export.
5. Touch Export.
The profile file (dwprofile_x.db, where x = name of the profile) is saved to the root of the On-device Storage.
Restoring DataWedge
1. Touch .
2. Touch Settings.
3. Touch Restore.
4. Touch Yes.
134
DataWedge
After making configuration or profile changes, export the new configuration or profile to the root of the
On-device Storage. The configuration file created is automatically named datawedge.db. The profile file
created is automatically named dwprofile_x.db, where x is the profile name. The files can then the copied to the
On-device Storage of other devices and imported into DataWedge on those devices. Importing a configuration
or profile replaces the existing settings.
Enterprise Folder
Internal storage contains the Enterprise folder (/enterprise). The Enterprise folder is persistent and maintains
data after an Enterprise reset. After an Enterprise Reset, DataWedge checks folder
/enterprise/device/settings/datawedge/enterprisereset/ for a configuration file, datawedge.db or a
profile file, dwprofile_x.db. If the file is found, it imports the file to replace any existing configuration or profile.
Auto Import
DataWedge supports remote deployment of a configuration to a device, using tools such as commercially
available third-party Mobile Device Management (MDM) systems. DataWedge monitors the
/enterprise/device/settings/datawedge/autoimport folder for the DataWedge configuration file
(datawedge.db) or a profile file (dwprofile_x.db). If a configuration or profile file is found, it imports the file to
replace any existing configuration or profile. Once the file has been imported it is deleted from the folder.
DataWedge begins using the imported configuration immediately.
The /enterprise folder cannot be seen with Files app or other user-level tools. Moving configuration files to and from the
/autoimport or /enterprisereset folders must be done programmatically, or with a staging client app or MDM.
Programming Notes
The following paragraphs provide specific programming information when using DataWedge.
To be able to capture bar code data and take a photo in the same application:
• Create a Datawedge profile pertaining to the picture taking Activity in your application that disables
scanning and use standard Android SDK APIs to control the Camera.
• The default Datawedge profile takes care of the scanning in the application. You might want to create
another DataWedge profile that caters to any specific scanning needs, associated to your Application's
Activity pertaining to scanning.
135
DataWedge
To disable DataWedge:
1. Swipe up from the bottom of the Home screen and touch DataWedge.
2. Touch .
3. Touch Settings.
4. Unselect the DataWedge enabled check box.
DataWedge APIs
DataWedge APIs operate primarily through Android intents - specific commands that can be used by other
applications to control data capture without the need to directly access the DataWedge UI. For more
information see, http://techdocs.zebra.com/datawedge/7-2/guide/api/.
Reporting
DataWedge 6.6 (and higher) can report the results of the importation of device Profiles. These HTML reports
display settings differences between the originating (source) database and the target (destination) device. This
allows administrators to easily identify differences and make adjustments to compensate for disparities in
hardware or software capabilities from one device to another. Reports always use the destination device as the
basis against which to compare incoming settings files.
DataWedge allows a native Android application to programmatically start, stop, or toggle the scan trigger state.
The application can issue an Android Broadcast Intent, to control the scanner, without requiring the scan key to
be pressed. The active DataWedge profile is required to control all the parameters during a scan operation.
Function Prototype
Parameters
The structure of the broadcast intent that resolves to the soft scan is:
136
DataWedge
The ScannerInputPlugin API command can be used to enable/disable the scanner plug-in being used by the
currently active Profile. Disabling the scanner plug-in effectively disables scanning in that Profile, regardless of
whether the Profile is associated or unassociated. Valid only when Barcode Input is enabled in the active
Profile.
NOTE: Use of this API changes only the runtime status of the scanner; it does not make persistent changes to the Profile.
Function Prototype
Parameters
action: String "com.symbol.datawedge.api.ACTION"
Return Values
None.
Error and debug messages will be logged to the Android logging system which then can be viewed and filtered
by the logcat command. You can use logcat from an ADB shell to view the log messages, for example:
137
DataWedge
Example
Comments
This intent API allows the scanner plug-in for the current Profile to be enabled or disabled. For example,
activity A launches and uses the intent API to switch to ProfileA in which the scanner plug-in is enabled, then at
some point it uses the Data Capture API to disable the scanner plug-in. Activity B is launched. In DataWedge,
ProfileB is associated with activity B. DataWedge switches to ProfileB. When activity A comes back to the
foreground, in the onResume method, activity A needs to use the intent API to switch back to ProfileA, then use
the intent API again to disable the scanner plug-in, to return back to the state it was in.
NOTE: Use of this API changes only the runtime status of the scanner; it does not make persistent changes to the Profile.
The above assumes that ProfileA is not associated with any applications/activities, therefore when focus switches back to
activity A, DataWedge will not automatically switch to ProfileA therefore activity A must switch back to ProfileA in its
onResume method. Because DataWedge will automatically switch Profile when an activity is paused, it is recommended
that this API function be called from the onResume method of the activity.
Enumerate Scanners
Use the enumerateScanners API command to get a list of scanners available on the device.
Function Prototype
Parameters
ACTION [String]: "com.symbol.datawedge.api.ENUMERATE_SCANNERS"
138
DataWedge
Return Values
The enumerated list of scanners will be returned via the broadcast Intent
"com.symbol.datawedge.api.ACTION_ENUMERATEDSCANNERLIST". The list of scanners is returned as a
string array (see the example below).
Error and debug messages are logged to the Android logging system which then can be viewed and filtered by
the logcat command. You can use logcat from an ADB shell to view the log messages. For example:
139
DataWedge
Example
//
// Call before sending the enumeration query
//
public void registerReciever(){
IntentFilter filter = new IntentFilter();
filter.addAction("com.symbol.datawedge.api.RESULT_ACTION");//RESULT_ACTION
filter.addCategory(Intent.CATEGORY_DEFAULT);
registerReceiver(enumeratingBroadcastReceiver, filter);
}
//
// Send the enumeration command to DataWedge
//
public void enumerateScanners(){
Intent i = new Intent();
i.setAction("com.symbol.datawedge.api.ACTION");
i.putExtra("com.symbol.datawedge.api.ENUMERATE_SCANNERS", "");
this.sendBroadcast(i);
}
//
// Create broadcast receiver to receive the enumeration result
//
private BroadcastReceiver enumeratingBroadcastReceiver = new BroadcastReceiver() {
@Override
public void onReceive(Context context, Intent intent) {
String action = intent.getAction();
Log.d(TAG, "Action: " + action);
if(action.equals("com.symbol.datawedge.api.RESULT_ACTION")){
//
// enumerate scanners
//
if(intent.hasExtra("com.symbol.datawedge.api.RESULT_ENUMERATE_SCANNERS")) {
ArrayList<Bundle> scannerList = (ArrayList<Bundle>)
intent.getSerializableExtra("com.symbol.datawedge.api.RESULT_ENUMERATE_SCANNERS");
if((scannerList != null) && (scannerList.size() > 0)) {
for (Bundle bunb : scannerList){
String[] entry = new String[4];
entry[0] = bunb.getString("SCANNER_NAME");
entry[1] = bunb.getBoolean("SCANNER_CONNECTION_STATE")+"";
entry[2] = bunb.getInt("SCANNER_INDEX")+"";
entry[3] = bunb.getString("SCANNER_IDENTIFIER");
Log.d(TAG, "Scanner:" + entry[0] + " Connection:" + entry[1] + " Index:" + entry[2] + " ID:" + entry[3]);
}
}
}
}
}
};
Comments
The scanner and its parameters are set based on the currently active Profile.
140
DataWedge
Use the setDefaultProfile API function to set the specified Profile as the default Profile.
Profile0 can be edited but cannot be associated with an application. That is, DataWedge allows manipulation
of plug-in settings for Profile0 but it does not allow assignment of a foreground application. This configuration
allows DataWedge to send output data to any foreground application other than applications associated with
user-defined Profiles when Profile0 is enabled.
Profile0 can be disabled to allow DataWedge to only send output data to those applications which are
associated in user-defined Profiles. For example, create a Profile associating a specific application, disable
Profile0 and then scan. DataWedge only sends data to the application specified in the user-created Profile.
This adds additional security to DataWedge enabling the sending of data only to specified applications.
Usage Scenario
A launcher application has a list of apps that a user can launch and that none of the listed apps has an
associated DataWedge Profile. Once the user has selected an app, the launcher needs to set the appropriate
DataWedge Profile for the selected app. This could be done by using setDefaultProfile to set the default
Profile to the required Profile. Then when the user launches the selected app, DataWedge auto Profile
switching switches to the default Profile (which is now the required Profile for that app).
If, for some reason, the launched app has an associated DataWedge Profile then that will override the set
default Profile.
When control is returned to the launcher application, resetDefaultProfile can be used to reset the default
Profile.
Function Prototype
Parameters
ACTION [String]: "com.symbol.datawedge.api.ACTION"
<profile name>: The Profile name (a case-sensitive string) to set as the default Profile.
Return Values
None.
Error and debug messages are logged to the Android logging system which then can be viewed and filtered by
the logcat command. You can use logcat from an ADB shell to view the log messages. For example:
141
DataWedge
Error messages are logged for invalid actions, parameters and failures, for example, Profile not found or
associated with an application.
Example
Comments
The API command has no effect if the specified Profile does not exist or if the specified Profile is already
associated with an application. DataWedge automatically switches Profiles when the activity is paused, so it is
recommended that this API function is called from the onResume method of the activity.
Zebra recommends that this Profile is created to cater to all applications/activities that would otherwise default
to using Profile0. This ensures that these applications/activities continue to work with a consistent
configuration.
Function Prototype
142
DataWedge
Parameters
ACTION [String]: "com.symbol.datawedge.api.ACTION"
Return Values
None.
Error and debug messages are logged to the Android logging system which then can be viewed and filtered by
the logcat command. You can use logcat from an ADB shell to view the log messages. For example:
Error messages are logged for invalid actions, parameters and failures, for example, Profile not found or
associated with an application.
Example
Comments
None.
Switch To Profile
Profiles Recap
DataWedge is based on Profiles and plug-ins. A Profile contains information on how DataWedge should
behave with different applications.
143
DataWedge
• Associated application
• Input plug-in configurations
• Output plug-in configurations
• Process plug-in configurations
DataWedge includes a default Profile, Profile0, that is created automatically the first time DataWedge runs.
Using Profiles, each application can have a specific DataWedge configuration. For example, each user
application can have a Profile which outputs scanned data in the required format when that application comes
to the foreground. DataWedge can be configured to process the same set of captured data differently based on
the requirements of each application.
NOTE: Use of this API changes only the runtime status of the scanner; it does not make persistent changes to the Profile.
A single Profile may be associated with one or many activities/apps, however, given an activity, only one Profile may be
associated with it.
Usage Scenario
An application has two activities. Activity A only requires EAN13 bar codes to be scanned. Activity B only
requires Code 128 bar codes to be scanned. Profile EAN13 is configured to only scan EAN13 bar codes and is
left unassociated. Profile Code128 is configured to scan Code 128 and is left unassociated. When Activity A
launches it uses SwitchToProfile to activate Profile EAN13. Similarly, when Activity B launches it uses
switchToProfile to activate Profile Code128.
If another activity/app comes to the foreground, DataWedge auto Profile switching sets the DataWedge Profile
accordingly either to the default Profile or to an associated Profile.
When Activity A (or Activity B) comes back to the foreground it uses switchToProfile to reset the Profile back to
Profile B (or Profile M).
Function Prototype
Parameters
ACTION [String]: "com.symbol.datawedge.api.ACTION"
<profile name>: The Profile name (a case-sensitive string) to set as the active Profile.
Return Values
None.
Error and debug messages are logged to the Android logging system which then can be viewed and filtered by
the logcat command. You can use logcat from an ADB shell to view the log messages. For example:
144
DataWedge
Error messages are logged for invalid actions, parameters and failures, for example, Profile not found or
associated with an application.
Example
Comments
This API function has no effect if the specified Profile does not exist or is already associated with an
application.
DataWedge has a one-to-one relationship between Profiles and activities; a Profile can be associated only with
a single activity. When a Profile is first created, it's not associated with any application, and is not activated
until associated. This makes it possible to create multiple unassociated Profiles.
For example, Profile A is unassociated and Profile B is associated with activity B. If activity A is launched and
uses SwitchToProfile function to switch to Profile A, then Profile A is active whenever activity A is in the
foreground. When activity B comes to the foreground, DataWedge automatically switches to Profile B.
When activity A returns to the foreground, the app must use SwitchToProfile again to switch back to Profile
A. This would be done in the onResume method of activity A.
NOTE: Use of this API changes only the runtime status of the scanner; it does not make persistent changes to the Profile.
145
DataWedge
Notes
Because DataWedge automatically switches Profile when the activity is paused, Zebra recommends that this
API function is called from the onResume method of the activity.
After switching to a Profile, this unassociated Profile does not get assigned to the application/activity and is
available to use in the future with a different app/activity.
For backward compatibility, DataWedge’s automatic Profile switching is not affected by the above API
commands. This why the commands work only with unassociated Profiles and apps.
Every second…
• Sets newProfileId to the associated Profile ID of the current foreground activity.
• If no associated Profile is found, sets newProfileId to the associated Profile ID of the current foreground
app.
• If no associated Profile is found, sets newProfileId to the current default Profile (which MAY NOT be
Profile0).
• Checks the newProfileId against the currentProfileId. If they are different:
• deactivates current Profile
• activates new Profile (newProfileId)
• sets currentProfileId = newProfileId
146
Application Deployment
Introduction
This chapter describes features in Android including new security features, how to package applications, and
procedures for deploying applications onto the device.
Security
The device implements a set of security policies that determine whether an application is allowed to run and, if
allowed, with what level of trust. To develop an application, you must know the security configuration of the
device, and how to sign an application with the appropriate certificate to allow the application to run (and to run
with the needed level of trust).
NOTE: Ensure the date is set correctly before installing certificates or when accessing secure web sites.
Secure Certificates
If the VPN or Wi-Fi networks rely on secure certificates, obtain the certificates and store them in the device’s
secure credential storage, before configuring access to the VPN or Wi-Fi networks.
If downloading the certificates from a web site, set a password for the credential storage. The device supports
X.509 certificates saved in PKCS#12 key store files with a .p12 extension (if key store has a .pfx or other
extension, change to .p12).
The device also installs any accompanying private key or certificate authority certificates contained in the key
store.
2. Swipe down from the Status bar to open the Quick Access panel and then touch .
3. Touch Security & location > Advanced > Encryption & credentials.
4. Touch Install from storage.
5. Navigate to the location of the certificate file.
147
Application Deployment
10.Touch OK.
The certificate can now be used when connecting to a secure network. For security, the certificate is
deleted from the internal memory.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
Development Tools
Android Application Development
Development Workstation
Android development tools are available at developer.android.com.
To start developing applications for the device, download Android Studio. Development can take place on a
Microsoft® Windows®, Mac® OS X®, or Linux® operating system.
Applications are written in the Java language, but compiled and executed in the Dalvik virtual machine. Once
the Java code is compiled cleanly, the developer tools make sure the application is packaged properly,
including the AndroidManifest.xml file.
148
Application Deployment
Android Studio contains a full featured IDE as well as SDK components required to develop Android
applications.
Target Device
Open the Developer options screen to set development related settings.
By default, the Developer Options are hidden. To un-hide the developer options, swipe down from the Status
bar to open the Quick Access panel and then touch .
Touch System > About device. Scroll down to Build number. Tap Build number seven times until You are
now a developer appears.
Touch System > Developer options. Slide the switch to the ON position to enable developer options.
EMDK for Android provides developers with a comprehensive set of tools to easily create powerful
line-of-business applications for enterprise mobile computing devices. It's designed for Google's Android SDK
and Android Studio, and includes class libraries, sample applications with source code, and all associated
documentation to help your applications take full advantage of what Zebra devices have to offer.
The kit also delivers Profile Manager, a GUI-based device configuration tool providing exclusive access to the
Zebra MX device management framework. This allows developers to configure Zebra devices from within their
applications in less time, with fewer lines of code and with fewer errors.
StageNow
StageNow is Zebra's next-generation Android Staging Solution built on the MX platform. It allows quick and
easy creation of device profiles, and can deploy to devices simply by scanning a bar code, reading a tag, or
playing an audio file.
GMS Restricted
GMS Restricted mode deactivates Google Mobile Services (GMS). All GMS apps are removed from the device
and communication with Google (analytics data collection and location services) is disabled. It also provides
enhanced security and privacy.
Use StageNow to disable or enable GMS Restricted mode. After a device is in GMS Restricted mode, enable
and disable individual GMS apps and services using StageNow. To ensure GMS Restricted mode persists
149
Application Deployment
after an Enterprise Reset, use the Persist Manager option in StageNow. For more information on StageNow,
refer to techdocs.zebra.com.
ADB driver for Windows and Linux are available on the Zebra Support Central web site at
www.zebra.com/support. Download the ADB and USB Driver Setup package. Follow the instructions with the
package to install the ADB and USB drivers for Windows and Linux.
1. Swipe down from the Status bar to open the Quick Access panel, and then touch .
5. Touch .
NOTE: If device number does not appear, ensure that ADB drivers are installed properly.
13.Touch .
Application Installation
After an application is developed, install the application onto the device using one of the following methods:
• USB connection, see Installing Applications Using the USB Connection.
• Android Debug Bridge, see Installing Applications Using the Android Debug Bridge.
• microSD Card, see Installing Applications Using a microSD Card.
150
Application Deployment
• Mobile device management (MDM) platforms that have application provisioning. Refer to the MDM software
documentation for details.
1. Connect the device to a host computer using the Rugged Charge/USB cable.
2. Pull down the Notification panel and touch USB for Charging.
7. Swipe the screen up and select to view files on the Internal Storage.
151
Application Deployment
11.To confirm installation and accept what the application affects, touch Install otherwise touch Cancel.
12.Touch Open to open the application or Done to exit the installation process. The application appears in the
App list.
Ensure that the ADB drivers are installed on the host computer. See ADB USB Setup.
1. Connect the device to a host computer using USB. See USB Communication.
2. Swipe down from the Status bar to open the Quick Access panel and then touch .
152
Application Deployment
CAUTION: When connecting the device to a host computer and mounting its microSD card, follow the host computer’s in-
structions for connecting and disconnecting USB devices, to avoid damaging or corrupting files.
1. Connect the device to a host computer using USB. See USB Communication.
2. Copy the application APK file from the host computer to the microSD card.
3. Remove the microSD card from the host computer.
4. Press and hold the Power button on the device until the menu appears.
5. Touch Power off.
6. Remove the battery from the device.
7. Remove the keypad.
8. Slide the microSD card holder to the Open position.
9. Lift the microSD card holder.
10.Insert the microSD card into the card holder door ensuring that the card slides into the holding tabs on each
side of the door.
11.Close the microSD card holder door and slide the door to the Lock position.
12.Replace the keypad.
13.Insert the battery.
14.Press and hold the Power button to turn on the device.
15.Swipe the screen up and select to view files on the microSD card.
153
Application Deployment
20.To confirm installation and accept what the application affects, touch Install otherwise touch Cancel.
21.Touch Open to open the application or Done to exit the installation process. The application appears in the
App list.
Uninstalling an Application
To uninstall an application:
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
154
Application Deployment
6. Touch Uninstall.
7. Touch OK to confirm.
It is strongly recommended that prior to use, you must format the microSD card on the device.
155
Application Deployment
1. Copy the System Update zip file to the root of the microSD card.
• Copy the zip file to a microSD card using a host computer (see USB Communication for more
information), and then installing the microSD card into the device (see Replacing the microSD Card for
more information).
• Connect the device with a microSD card already installed to the host computer, and copy zip file to the
microSD card. See USB Communication for more information. Disconnect the device from the host
computer.
2. Press and hold the Power button until the menu appears.
3. Touch Restart.
4. Touch OK. The device resets.
5. Press and hold the Trigger button until the device vibrates. The System Recovery screen appears.
6. Press the Up and Down buttons to navigate to apply from sdcard.
7. Press the Enter button.
8. Use the Up and Down buttons to navigate to Full OTA Package or Diff OTA Package.
9. Press the Enter button.
10.Use the Up and Down buttons to navigate to the System Update file.
11.Press the Power button. The System Update installs and then the device returns to the Recovery screen.
12.Press the Power button to reboot the device.
NOTE: If installing GMS software on a device that had Non-GMS software or Non-GMS software on a device that had GMS
software, perform a Factory or Enterprise reset (retains enterprise data).
Using ADB
1. On the device, swipe down from the Status bar to open the Quick Access panel and then touch .
2. Touch System > Developer options.
3. Slide the switch to the ON position.
4. Touch USB Debugging. A check appears in the check box. The Allow USB debugging? dialog box
appears.
5. Touch OK.
6. On the host computer, open a command prompt window and use the adb command:
adb devices
The following displays:
List of devices attached
XXXXXXXXXXXXXXX device (where XXXXXXXXXXXXXXX is the device number).
NOTE: If device number does not appear, ensure that ADB drivers are installed properly.
156
Application Deployment
7. Type:
adb reboot recovery
NOTE: If installing GMS software on a device that had Non-GMS software or Non-GMS software on a device that had GMS
software, perform a Factory or Enterprise reset (retains enterprise data).
1. On the device, swipe down from the Status bar to open the Quick Access panel and then touch .
Before performing an Enterprise Reset, provision all necessary configuration files and restore after the reset.
157
Application Deployment
It is strongly recommended that prior to use, you must format the microSD card on the device.
1. Copy the Enterprise Reset zip file to the root of the microSD card.
• Copy the zip file to a microSD card using a host computer (see USB Communication for more
information) and then installing the microSD card into the device (see Replacing the microSD Card for
more information).
• Connect the device with a microSD card already installed to the host computer and copy zip file to the
microSD card. See USB Communication for more information. Disconnect the device from the host
computer.
2. Press and hold the Power button until the menu appears.
3. Touch Reboot.
4. Touch OK. The device resets.
5. Press and hold the Trigger button until the device vibrates. The System Recovery screen appears.
6. Press the Up and Down buttons to navigate to apply from sdcard.
7. Press the Enter button.
8. Press the Up and Down buttons to navigate to apply from adb.
9. Press Enter.
10.Use the Up and Down buttons to navigate to Full OTA Package or Diff OTA Package.
11.Press the Enter button.
12.Use the Up and Down buttons to navigate to the Enterprise Reset file.
13.Press the Power button. The Enterprise Reset occurs and then the device returns to the Recovery screen.
14.Press the Power button.
Using ADB
1. On the device, swipe down from the Status bar to open the Quick Access panel and then touch .
158
Application Deployment
NOTE: If device number does not appear, ensure that ADB drivers are installed properly.
7. Type:
adb reboot recovery
A Factory Reset erases all data in the /data and /enterprise partitions in internal storage and clears all
device settings. A Factory Reset returns the device to the last installed operating system image. To revert to a
previous operating system version, re-install that operating system image. See Performing a System Update
for more information.
1. Copy the Factory Reset zip file to the root of the microSD card.
• Copy the zip file to a microSD card using a host computer (see USB Communication for more
information) and then installing the microSD card into the device (see Replacing the microSD Card for
more information).
• Connect the device with a microSD card already installed to the host computer and copy zip file to the
microSD card. See USB Communication for more information. Disconnect the device from the host
computer.
159
Application Deployment
2. Press and hold the Power button until the menu appears.
3. Touch Reboot.
4. Touch OK. The device resets.
5. Press and hold the Trigger button until the device vibrates. The System Recovery screen appears.
6. Press the Up and Down buttons to navigate to apply from sdcard.
7. Press the Enter button.
8. Use the Up and Down buttons to navigate to Full OTA Package or Diff OTA Package.
9. Press the Enter button.
10.Use the Up and Down buttons to navigate to the Factory Reset file.
11.Press the Power button. The Factory Reset occurs and then the device returns to the Recovery screen.
12.Press the Power button.
Using ADB
1. On the device, swipe down from the Status bar to open the Quick Access panel and then touch .
NOTE: If device number does not appear, ensure that ADB drivers are installed properly.
7. Type:
adb reboot recovery
160
Application Deployment
Storage
161
Application Deployment
• Average used (%) - Indicates the average amount of memory (as a percentage) used during the period of
time selected (default - 3 hours).
• Free - Indicates the total amount of unused RAM.
• Memory used by apps - Touch to view RAM usage by individual apps.
Internal Storage
The device has internal storage. The internal storage content can be viewed and files copied to and from when
the device is connected to a host computer. Some applications are designed to be stored on the internal
storage rather than in internal memory.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
2. Touch Storage.
External Storage
The device can have a removable microSD card. The microSD card content can be viewed and files copied to
and from when the device is connected to a host computer.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
2. Touch Storage.
162
Application Deployment
Portable storage displays the total amount of space on the installed and the amount used.
163
Application Deployment
3. Touch Format.
164
Application Deployment
You can format a microSD card as internal memory to increase the actual amount of the device’s internal
memory. Once formatted, the microSD card can only be read by this device. To format an installed microSD
card as internal memory:
1. Touch SD card.
165
Application Deployment
Enterprise Folder
The Enterprise folder (within internal flash) is a super-persistent storage that is persistent after a reset and an
Enterprise Reset. The Enterprise folder is erased during a Factory Reset. The Enterprise folder is used for
deployment and device-unique data. The Enterprise folder is approximately 128 MB (formatted). Applications
can persist data after an Enterprise Reset by saving data to the enterprise/user folder. The folder is ext4
formatted and is only accessible from a host computer using ADB or from an MDM.
App Management
Apps use two kinds of memory: storage memory and RAM. Apps use storage memory for themselves and any
files, settings, and other data they use. They also use RAM when they are running.
1. Swipe down from the Status bar to open the Quick Access panel and then touch .
166
Application Deployment
5. Touch an app, process, or service in the list to open a screen to view its details. Depending on the item, you
can change its settings, permissions, notifications, and force stop or uninstall the item.
Apps have different kinds of information and controls, but commonly include:
• Force stop - stop an app.
• Disable - disable an app.
• Uninstall - remove the app and all of its data and settings from the device. See Uninstalling an Application
for information about uninstalling apps.
• Storage - lists how much information is stored, and includes a button for clearing it.
• Data usage - provides information about data (Wi-Fi) consumed by an app.
• Permissions - lists the areas on the device that the app has access to.
• Notifications - set the app notification settings.
• Open by default - clears If you have configured an app to launch certain file types by default, you can clear
that setting here.
• Battery - lists the amount of computing power used by the app.
• Memory - lists the average app memory usage.
• Advanced
• Draw over other apps - allows an app to display on top of other apps.
Managing Downloads
Files and apps downloaded using the Browser or Email are stored on the Internal storage in the Download
directory. Use the Downloads app to view, open, or delete downloaded items.
167
Application Deployment
3. Touch and hold an item, select items to delete and touch . The item is deleted from the device.
168
Maintenance and
Troubleshooting
Introduction
This chapter includes instructions on cleaning and storing the device, and provides troubleshooting solutions for
potential problems during operation.
169
Maintenance and Troubleshooting
• Severe impact from dropping any battery-operated device on a hard surface could cause the battery to
overheat.
• Do not short circuit a battery or allow metallic or conductive objects to contact the battery terminals.
• Do not modify or remanufacture, attempt to insert foreign objects into the battery, immerse or expose to
water or other liquids, or expose to fire, explosion, or other hazard.
• Do not leave or store the equipment in or near areas that might get very hot, such as in a parked vehicle or
near a radiator or other heat source. Do not place battery into a microwave oven or dryer.
• Battery usage by children should be supervised.
• Please follow local regulations to properly dispose of used re-chargeable batteries.
• Do not dispose of batteries in fire.
• In the event of a battery leak, do not allow the liquid to come in contact with the skin or eyes. If contact has
been made, wash the affected area with water for 15 minutes, and seek medical advice.
• If you suspect damage to your equipment or battery, contact Customer Support to arrange for inspection.
Cleaning Instructions
CAUTION: Always wear eye protection.
Read warning label on alcohol product before using.
If you have to use any other solution for medical reasons please contact the Global Customer Support Center for more in-
formation.
WARNING: Avoid exposing this product to contact with hot oil or other flammable liquids. If such exposure occurs, unplug
the device and clean the product immediately in accordance with these guidelines.
100% of the active ingredients in any cleaner must consist of one or some combination of the following:
isopropyl alcohol, bleach/sodium hypochlorite1 (see important note below), or mild dish soap.
IMPORTANT: Use pre-moistened wipes and do not allow liquid cleaner to pool.
1When using sodium hypochlorite (bleach) based products, always follow the manufacturer’s recommended instructions:
use gloves during application and remove the residue afterwards with a damp alcohol cloth or a cotton swab to avoid
prolonged skin contact while handling the device.
Due to the powerful oxidizing nature of sodium hypochlorite, the metal surfaces on the device are prone to oxidation
(corrosion) when exposed to this chemical in the liquid form (including wipes). In the event that these type of disinfectants
come in contact with metal on the device, prompt removal with an alcohol-dampened cloth or cotton swab after the cleaning
step is critical.
Harmful Ingredients
The following chemicals are known to damage the plastics on the device and should not come in contact with
the device: acetone; ketones; ethers; aromatic and chlorinated hydrocarbons; aqueous or alcoholic alkaline
solutions; ethanolamine; toluene; trichloroethylene; benzene; carbolic acid and TB-lysoform.
Many vinyl gloves contain phthalate additives, which are often not recommended for medical use and are
known to be harmful to the housing of the device.
170
Maintenance and Troubleshooting
Do not apply liquid directly to the device. Dampen a soft cloth or use pre-moistened wipes. Do not wrap the
device in the cloth or wipe, instead gently wipe the unit. Be careful not to let liquid pool around the display
window or other places. Before use, allow the unit to air dry.
NOTE: For thorough cleaning, it is recommended to first remove all accessory attachments, such as hand straps or cradle
cups, from the mobile device and to clean them separately.
The device should not be handled while wearing vinyl gloves containing phthalates, or before hands are
washed to remove contaminant residue after gloves are removed.
If products containing any of the harmful ingredients listed above are used prior to handling the device, such as
hand sanitizer that contain ethanolamine, hands must be completely dry before handling the device to prevent
damage to the device.
IMPORTANT: If the battery connectors are exposed to cleaning agents, thoroughly wipe off as much of the chemical as
possible and clean with an alcohol wipe. It is also recommended to install the battery in the terminal prior to cleaning and
disinfecting the device to help minimize buildup on the connectors.
When using cleaning/disinfectant agents on the device, it is important to follow the directions prescribed by the
cleaning/disinfectant agent manufacturer.
• Alcohol wipes
• Lens tissue
• Cotton-tipped applicators
• Isopropyl alcohol
• Can of compressed air with a tube.
Cleaning Frequency
The cleaning frequency is at the customer’s discretion due to the varied environments in which the mobile
devices are used and may be cleaned as frequently as required. When dirt is visible, it is recommended to
clean the mobile device to avoid build up of particles which make the device more difficult to clean later on.
Housing
Thoroughly wipe the housing, including all buttons and triggers, using an approved alcohol wipe.
Display
The display can be wiped down with an approved alcohol wipe, but care should be taken not to allow any
pooling of liquid around the edges of the display. Immediately dry the display with a soft, non-abrasive cloth to
prevent streaking.
171
Maintenance and Troubleshooting
Exit Window
Wipe the exit window periodically with a lens tissue or other material suitable for cleaning optical material such
as eyeglasses.
CAUTION: After cleaning the battery connectors with bleach-based chemicals, follow the Battery Connector Cleaning in-
structions to remove bleach from the connectors.
CAUTION: After cleaning the cradle connectors with bleach-based chemicals, follow the Cleaning Cradle Connectors in-
structions to remove bleach from the connectors.
172
Maintenance and Troubleshooting
Troubleshooting
MC93XX
The following tables provides typical problems that might arise and the solution for correcting the problem.
173
Maintenance and Troubleshooting
174
Maintenance and Troubleshooting
175
Maintenance and Troubleshooting
176
Maintenance and Troubleshooting
177
Maintenance and Troubleshooting
178
Maintenance and Troubleshooting
179
Specifications
Introduction
The following sections provide technical specification for the device.
The following table summarizes the MC93XX’s intended operating environment and technical hardware
specifications.
Item Description
Physical Characteristics
Dimensions 9.4 in L x 3.45 in W x 7.4 in H
240 mm L x 88 mm W x 189 mm H
Weight 26.9 oz./765g with battery
Display 4.3” WVGA (800 x 480), color display
Imager Window Corning® Gorilla® Glass
Touch Panel Dual mode capacitive touch with finger, gloved finger or stylus input
(conductive stylus sold separately), Screen Protector, Corning®
Gorilla® Glass touch panel with air gap (standard model) or optically
bonded (freezer model).
Backlight LED backlight display
Battery 7000mAh PowerPrecision+ standard battery
5000mAh PowerPrecision+ freezer battery
7000mAh PowerPrecision+ non-incendive battery
Expansion Slot User accessible microSD slot. Supports up to 32 GB microSDHC and
up to 256 GB microSDXC.
Network Connections USB 2.0 High Speed (Host & Client), WLAN and WPAN (Bluetooth)
Notification Audible tone; Multi-color LED bar (between keyboard and display), and
haptic feedback.
Keypad Options 53 Key Standard, 53 Key Terminal Emulation (VT, 5250, and 3270), 43
Key Shifted Alpha, 34 Key Numeric, 58-Keys OmniiXT15f, and
29-Keys Shifted Alpha.
180
Specifications
Item Description
Voice Speaker, Microphone, PTT Voice (Internal Speaker and Bluetooth
Wireless Headset Support).
Audio Speaker
Performance Characteristics
CPU Qualcomm Snapdragon ™ 660 octa-core, 2.2 GHz
Operating System Android 8.1 Oreo with Zebra’s Restricted Mode for control over GMS
and other services.
Memory 4 GB RAM/32 GB Flash pSLC.
Output Power (USB) USB: 5 VDC @ 500 mA max.
User Environment
Operating Temperature Standard: -4°F to 122°F/-20°C to +50°C
Freezer: -22°F to 122°F/-30°C to +50°C
Storage Temperature -40°F to 158°F/-40°C to 70°C
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity Standard: 5% to 95%, non-condensing
Freezer: 5% to 95%, condensing
Drop Specification Standard: 8 ft. (2.4m) drops to concrete across temperature per
MIL-STD-810G.
Freezer: 7 ft. (2.1m) drops to concrete across temperature per
MIL-STD-810G.
Tumble Specification 4,000 3.3 ft. (1m) tumbles; meets and exceeds IEC tumble
specification.
Sealing IP67 and IP65 per IEC sealing specification.
Vibration 4 g’s PK Sine (5 Hz to 2 kHz); 0.04 g 2/Hz Random (20 Hz to 2 kHz);
60 minute duration per axis, 3 axis
Thermal Shock -40°C to 70°C (-40°F to 158°F) rapid transition.
Electrostatic Discharge (ESD) +/-15kVdc air discharge
+/-8kVdc direct discharge
+/-8kVdc indirect discharge
Interactive Sensor Technology (IST)
Ambient Light Sensor Ambient light sensor used to auto adjust display and keyboard back
light brightness.
Motion Sensor 3-axis accelerometer provides motion-sensing for dynamic screen
orientation.
Wireless LAN Data Communications
Radio IEEE 802.11 a/b/g/n/ac/d/h/i/r/k/w; Wi-Fi certified; IPv4, IPv6, 2x2
MU-MIMO
Data Rates 5GHz: 802.11a/n/ac — up to 866.7 Mbps
2.4GHz: 802.11b/g/n — up to 300 Mbps
181
Specifications
Item Description
Operating Channels Channel 1-13 (2412-2472 MHz); Chan 36-165 (5180-5825 MHz)
Channel Bandwidth: 20, 40, 80 MHz
Actual operating channels/ frequencies and bandwidths depend on
regulatory rules and certification agency.
Security and Encryption WEP (40 or 104 bit); WPA/WPA2 Personal (TKIP and AES);
WPA/WPA2 Enterprise (TKIP and AES) - EAP-TTLS (PAP, MSCHAP,
MSCHAPv2), EAP-TLS, PEAPv0-MSCHAPv2, PEAPv1-EAP-GTC and
LEAP, EAP-PWD
Data in Motion: FIPS 140-2 Level 1
Data at Rest: FIPS 140-2 Level 1
Certifications WFA (802.11n, WMM-PS, 802.11ac, PMF, WMM-AC, Voice
Enterprise, WiFi Direct and WPS 2.0)
Fast Roam PMKID caching; Cisco CCKM; 802.11r; OKC
Wireless PAN Data
Bluetooth Class II, Bluetooth V5.0 with BR/EDR and Bluetooth Low Energy (BLE)
Support
Communication and Messaging
Workforce Connect PTT Express (included) provides instant push-to-talk small group communications
across Wi-Fi networks. Workforce Connect PTT Pro (supported) provides a scalable network agnostic
push-to-talk solution which also includes messaging, location services and two-way radio integration.
Workforce Connect Voice client (supported) enables the MC9300 to function as a full featured mobile
telephone with multi-line capability across Wi-Fi networks.
Device Approvals and Compliance
TAA Trade Agreement Act optional on select configurations Complaint,
(Optional on select configurations) FIPS 140-2 (DIM & DAR) support; FIPS 140-2 Level 1: Data in Motion
and Data at Rest
Non-Incendive (NI) Suitable for use in Class I, II, III Div 2
(Optional on select configurations) Safety: cULus Listing - ISA/ANSA 12.12.01
Gases: Class I - Groups A, B, C, D
Dusts: Class II - Groups F, G
Fibers & Flyings: Class III
-20°C ≤ Ta ≥ +50°C T6
Peripherals and Accessories
Cradles Single slot USB/Charge, Four-slot charger only.
Battery Chargers 4-slot battery charger and16-slot battery charger.
Other Accessories USB/charge snap-on cup, forklift holder, soft holster, screen protector,
hand strap, stylus
182
Specifications
Item Description
Data Capture
Scanning SE965: 1D standard range scan engine.
SE4750-SR: Standard Range omnidirectional 1D/2D imaging engine
reads 1D and 2D symbols.
(Premium only).
SE4850-ER: Extended range omnidirectional 1D/2D imaging engine
reads 1D and 2D symbols.
SE4750DPM: Omnidirectional 1D and 2D imaging engine reads Direct
Part Marking.
SE4750DPW: Omnidirectional 1D and 2D imaging engine reads wide
1D and Direct Part Marking.
SE4770-SR: Standard range next generation omnidirectional 1D/2D
imaging engine.
Camera Front: 5MP fixed focus and 2.0 aperture.
Rear: 13MP autofocus, 2.2 aperture, flash LED generates balanced
white light, support torch mode, and supports rear camera barcode
scanning.
Near Field Communications Tap to Pair, ISO 14443 Type A and B, FeliCa cards in Reader Mode,
(NFC) ISO 15693 cards, P2P mode and Card Emulation via Host (HCE)
support.
Data Capture Options
Laser Decode Capability Code 39, Code 128, Code 93, Codabar, Code 11, Discrete 2 of 5,
Interleaved 2 of 5, EAN-8, EAN-13, MSI, UPCA, UPCE, UPC/EAN
supplementals, Coupon Code, Trioptic 39, Webcode, RSS-14, RSS
Limited, RSS Expanded, Chinese 2 of 5
Imaging Decode Capability Code 39, Code 128, Code 93, Codabar, Code 11, Interleaved 2 of 5,
Discrete 2 of 5, MSI, EAN-8, EAN-13, UPCA, UPCE, UPC/EAN
supplementals, Coupon Code, Trioptic 39, Webcode, TLC39,
Composite AB, Composite C, Micro PDF-417, PDF-417, Macro
PDF-417, (Macro) Micro PDF-417, QR Code, RSS Expanded, RSS
Limited, RSS-14, Data Matrix, Maxi Code, US Postnet, US Planet, UK
4-state, Australian 4-state, Canadian 4-state, Japanese 4-state, Dutch
Kix, Chinese 2 of 5, USPS 4-state (US4CB), Aztec, microQR, Dotcode
P9 P1
183
Specifications
1-Slot USB Charge Cradle with Spare Battery Charger Technical Specifications
Table 19 1-Slot USB Charge Cradle with Spare Battery Charger Technical Specifications
Item Description
Dimensions Height: 87.9 mm (3.46 in)
Width: 152.4 mm (6.00 in)
Depth: 159.4 mm (6.28 in)
Weight 522 g (18.41 oz)
Input Voltage 12 VDC
Power Consumption 28 watts
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity 5% to 95% non-condensing
Drop 75 cm (30 in.) to concrete; 2 drops/side for a total of 12 drops at room
temperature (23°C).
Electrostatic Discharge (ESD) +/- 15 kV air
+/- 8 kV contact
+/- 8 kV indirect discharge
184
Specifications
Item Description
Dimensions Height: 116.5 mm (4.59 in)
Width: 152.4 mm (6.00 in)
Depth: 132.7 mm (5.22 in)
Weight 1879 g (66.28 oz)
Input Voltage 12 VDC
Power Consumption 63 watts
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity 5% to 95% non-condensing
Drop 75 cm (30 in.) to concrete; 2 drops/side for a total of 12 drops at room
temperature (23°C).
Electrostatic Discharge (ESD) +/- 15 kV air
+/- 8 kV contact
+/- 8 kV indirect discharge
Item Description
Dimensions Height: 116.5 mm (4.59 in)
Width: 489.0 mm (19.25 in.)
Depth: 132.7 mm (5.22 in)
Weight 2070 g (37.67 oz)
Input Voltage 12 VDC
Power Consumption 80 watts
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity 5% to 95% non-condensing
Drop 75 cm (30 in.) to concrete; 2 drops/side for a total of 12 drops at room
temperature (23°C).
Electrostatic Discharge (ESD) +/- 15 kV air
+/- 8 kV contact
+/- 8 kV indirect discharge
185
Specifications
Item Description
Dimensions Height: 104.4 mm (4.11 in.)
Width: 121.9 mm (4.80 in.)
Depth: 142.4 mm (5.61 in.)
Weight 619.3 g (21.85 oz)
Input Voltage 12 VDC
Power Consumption 30 watts
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity 5% to 95% non-condensing
Drop 75 cm (30 in.) to concrete; 2 drops/side for a total of 12 drops at room
temperature (23°C).
Electrostatic Discharge (ESD) +/- 15 kV air
+/- 8 kV contact
+/- 8 kV indirect discharge
Item Description
Dimensions Height: 104.9 mm (4.13 in.)
Width: 489.0 mm (19.25 in.)
Depth: 142.4 mm (5.61 in.)
Weight 2480 g (87.48 oz)
Input Voltage 12 VDC
Power Consumption 106 watts
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity 5% to 95% non-condensing
Drop 75 cm (30 in.) to concrete; 2 drops/side for a total of 12 drops at room
temperature (23°C).
Electrostatic Discharge (ESD) +/- 15 kV air
+/- 8 kV contact
+/- 8 kV indirect discharge
186
Specifications
Item Description
Dimensions Height: 55.8 mm (2.19 in.)
Width (with cable): 199.5 mm (7.85 in.)
Depth 52.8mm (2.07 in.)
Weight 76.1 g (2.68 oz)
Input Voltage 5 VDC
Power Consumption 12 watts
Operating Temperature 0°C to 50°C (32°F to 104°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Charging Temperature 0°C to 40°C (32°F to 104°F)
Humidity 5% to 95% non-condensing
Drop 75 cm (30 in.) to concrete; 2 drops/side for a total of 12 drops at room
temperature (23°C).
Electrostatic Discharge (ESD) +/- 15 kV air
+/- 8 kV contact
+/- 8 kV indirect discharge
187
Index
188
Index
Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 N
Composite AB . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
decode lengths . . . . . . . . . . . . . . . . . . . . . . . . . . 109 notational conventions . . . . . . . . . . . . . . . . . . . . . . . . . 13
Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DotCode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 P
GS1 DataBar Limited . . . . . . . . . . . . . . . . . . . . . 107
HAN XIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 photo transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . 107
Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 R
MSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Trioptic 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 reader params . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
UK Postal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 rubber boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
UPCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 RxLogger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
UPCE0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
UPCE1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 configuration file . . . . . . . . . . . . . . . . . . . . . . . . . .82
US Planet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 disable logging . . . . . . . . . . . . . . . . . . . . . . . . . . .82
decoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 enable logging . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
disconnect host computer . . . . . . . . . . . . . . . . . . . . . . 90 extract log files . . . . . . . . . . . . . . . . . . . . . . . . . . .83
RxLogger Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
F
S
file transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
scan params . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
H settings
hand strap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 datawedge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
harmful ingredients . . . . . . . . . . . . . . . . . . . . . . . . . . 170 setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
hot swap mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
software versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
I
T
install microSD card . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
transferring files using USB . . . . . . . . . . . . . . . . . . . . .89
troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173
M
maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 U
approved cleanser active ingredients . . . . . . . . . 170
battery safety guidelines . . . . . . . . . . . . . . . . . . . 169 UDI params . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
clean battery connectors . . . . . . . . . . . . . . . . . . . 172 UPC EAN params . . . . . . . . . . . . . . . . . . . . . . . . . . .109
clean camera and exit window . . . . . . . . . . . . . . 172 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
clean cradle connectors . . . . . . . . . . . . . . . . . . . 172
clean display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 V
clean housing . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
cleaning frequency . . . . . . . . . . . . . . . . . . . . . . . 171 voice input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
cleaning instructions . . . . . . . . . . . . . . . . . . . . . . 170
cleaning materials required . . . . . . . . . . . . . . . . . 171
W
device cleaning instructions . . . . . . . . . . . . . . . . 171
harmful ingredients . . . . . . . . . . . . . . . . . . . . . . . 170 Wi-Fi direct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
maintaining the device . . . . . . . . . . . . . . . . . . . . 169 WPS pin entery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
special cleaning notes . . . . . . . . . . . . . . . . . . . . . 171 WPS push button . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
multibarcode params . . . . . . . . . . . . . . . . . . . . . . . . . 116
189
www.zebra.com