CICP1800T: Turbo Superterm-8 Capacities

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Turbo Superterm: 8-Door Intelligent Controller

CICP1800T In addition to memory and power expansion capabilities, the


Turbo Superterm will accept up to 3 input/output expansion
The eight-reader Turbo Superterm (CICP1800T) supports 8 boards. The Turbo Superterm can be ordered with the expan-
readers and has 24 inputs, 1 tamper alarm and 17 outputs. A sion boards pre-installed at the factory. The boards can also be
locking steel enclosure, power supply and battery are included. ordered separately and field installed within the Turbo Super-
term enclosure. The boards are mounted to the inside of the
Turbo Superterm-8 is an expandable intelligent controller ca- hinged enclosure cover. The Alarm Expander Board provides
pable of supporting all access control functions for one to eight 16 supervised inputs while the Relay Expander Board provides
doors. This distributed processor-based panel will operate as a 16 relay outputs and 8 unsupervised inputs.
standalone unit in the event server-communications are inter-
rupted. The Turbo Superterm is programmed via Continental Turbo Superterm-8 Capacities
Instruments (CIC) CardAccess® software program, a Windows-
• 40,000 cards standard (exp. to 210,000)
based access control and security management solution. Once • 8 Five-wire, Wiegand output readers
programmed, the controller does not require continuous server • 8 Seven-wire X-Y Matrix type keypads
communications, as it automatically stores system transactions • 24 Supervised inputs
in its internal memory. The Turbo Superterm’s memory is field • 48 Additional inputs (supervised)
expandable, allowing for greater cardholder populations and/ • 17 Form C rated standard outputs at 3A@24VDC/VAC
or a larger transaction buffer. The controller’s Flash EPROM • 48 Additional Form C rated outputs at 3A@24VDC/VAC
firmware is easily upgraded when additional features or system • 1000 Standard transaction buffer (exp. to 250,000)
enhancements are required. Continental’s controllers feature • 256 Time schedules
extensive multi-stage lightning/transient protection on-board • 30,000 Access groups
• 5 Sets of 100 holidays
for maximum reliability even in harsh environments.
• APL Listed for FIPS compliance
• Capable of processing 256 bit cards from card to controller to
The Turbo Superterm accepts industry standard Wiegand software
output devices and supports virtually all card/reader technolo- • 1,000,000 cardholders in the controller (with accelerator board)
gies. Proximity, Biometric, Magnetic Stripe, Barcode, Wiegand, • NVR/DVR integration
Barium Ferrite, Keypad and Smart Readers are easily connected • Sophisticated Alarm Integration
and controlled. The Turbo Superterm can store multiple card • Downloads at 52 MIPS (Million Instructions Per Second with
(bit) formats in its internal memory, making it a cost-effective accelerator board)
retrofit panel. Supporting multiple bit formats allows exist- • Reader Power 800mA@5VDC, 500mA@12VDC
ing card populations and readers to remain in place. Up to 63 • Battery Backup 4-6 hours included
CIC Intelligent Controllers (Microterm, Miniterm, Smarterm or • Enclosure Size 21.5”H x 21.25”W x 7”D, 48lbs.
Turbo Superterm) can be intermixed on the same communica- • UL Listings Optional UL294, UL1076, CE
tions network. Multiple communication networks (ports) can Note: *A maximum of 3 Expansion Boards in any combination may be added to the Turbo
be connected to the CardAccess® server for maximum system Superterm
expansion. Controller communication choices include: hard-
wire (repeat or multi-drop mode), LAN/WAN, dial-up or fiber
optics for maximum flexibility. Continental Instruments supports
RS232, RS422 and RS485 communication formats for optimal
system configuration. A Napco Security Group Company
Turbo Superterm-8 Components A standard on-board power supply provides 800mA RS422 Repeat Mode Communications N
@5VDC or 500mA @12VDC for reader power. An Up 4000'
CICE1940PL-1
max. distance between controllers.
to 63 controllers on a Repeat Mode Netw
QTY. Part No. Description additional 3A@12VDCPolling isRS232 Line Converter
available with the optional
to RS422 RS422 RS422 RS422
1 CICP1800T or Eight (8) reader controller with expanded power supply. The Turbo Superterm can
Required if server is not located
within 50
Max. 4000' Max. 4000' Max. 400

standard 40,000 card capacity, 24 be ordered with a factory installed expanded power Suppperterm Suppperterm
Sm
marterm
m

supervised alarm inputs, tamper RS232 RS422

alarm, and 17 relay outputs.


supply. The expanded Max.power
50' supply can also be ordered
x. 4000'

Unit ships complete in a locked separately and field installed within the Turbo Superterm
CardAccess 3000
steel enclosure including a 7AH enclosure.
Database and The expanded power supply includes a 12AH
standby battery for memory and Communications
standby battery, an upgrade to the standard 7AH battery.
Server
system operation. The standard 7AH and expanded 12AH batteries provide
CICP1800TEXP Same as above, with expanded 4–6 hours standby. In addition to the rechargeable
power supply. Required if more standby battery, each Turbo Superterm includes a lithium
than one Relay Expander Board
(CICP1800TRB) is used or addi-
battery for up to one year of data protection. UL294
(Access Control System Unit), UL1076 (Proprietary Multi-drop Mode Communications
RS422Burglar
tional 12VDC is needed. A 12AH 4000' overall max. distance. Up to 63 controllers on a Multi-d
CICE1940PL-1
Battery is included. Alarm Unit) listings Polling Line Converter
RS232 to RS422 RS422 RS422 RS422
1 Standard 14VAC Power Supply via step- Required if server is not located

down transformer mounted inside UL294 (Access Control System Unit), UL1076 within 50
Suppperterm Suppperterm
Sm
marterm
m

enclosure. 10’ power line cable (Proprietary BurglarRS232


Alarm Unit)RS422
listings and CE are
Max. 50'
with 110VAC plug is included. optional with the Turbo Superterm-8.
1 Standard 7 AH Battery Backup included. CardAccess 3000
Database and
1 Optional CICEXPPWS 12V Linear Expanded Power Communications Maximum distance between 1st and last controller is 4000'. A C
Typical Door Configuration
Server required after every ten (10) Controllers placed on a multi-drop
Supply provides 3A @ 12VDC
Auxiliary Power. 12AH Battery is See Continental Access Configuration Guide for addi-
included. tional detailed system wiring information.
2 Optional CICP1800MB2X2 Memory Board - 2MB per memo-
ry board (up to 210,000 cards w/4 A or B
MB of memory expansion). RS422 to Panels

Up to 3 CICP1800RB Relay Expander Board - 16 output


Optional* relays, 8 alarm inputs (Unsuper- RS422 Repeat Mode Communications Network
vised). 4000' max. distance between controllers. Door Lock
CICE1940PL-1 Up to 63 controllers on a Repeat Mode Network.
Power Supply G

Up to 3 CICP1800AB Polling LineExpander


Alarm Converter Board - 16 alarm
Continental Request to Exit
Motion Detector
RS232 to RS422 RS422 RS422G RS422 RS422 Door Lock
Optional* inputs (Supervised). UL Listed. Max. 4000'
Required if server is not located
Door Contact
Max. 4000' Max. 4000' Max. 4000'
G Door Contact

within 50 G G
Note: *A maximum of 3 Expansion Boards in any combination may be added to the Turbo
Suppperterm Suppperterm Request Request
Superterm Sm to Exit
marterm
m to Exit
RS232 RS422 Miiniterm Bu

Max. 50' x. 4000' C


D
G
Card Reader

CardAccess 3000 H Electric


Door Strike
Database and
Communications NOTE: Request to Exit motion detectors will require
Server an additional 12VDC power cable. Exit devices are
typically mounted on the egress side of door.

CICP1300 Two Door intelligent Controller


Continental Instrument’s Controllers can connect to the CardAccess Server via hardwire (shown below), LAN/WAN
dial-up modem or fiber optics. See the Configuration Guide for additional detailed system information.
RS422 Multi-drop Mode Communications Network
4000' overall max. distance. Up to 63 controllers on a Multi-drop Mode Network.
CICE1940PL-1
Polling Line Converter
RS232 to RS422 RS422 RS422 RS422 RS422
Required if server is not located
within 50
Suppperterm Suppperterm
Sm
marterm
m

RS232 RS422 Miiniterm

Max. 50' C

CardAccess 3000
Database and
Communications Maximum distance between 1st and last controller is 4000'. A CICE1941 Line Driver is
Server required after every ten (10) Controllers placed on a multi-drop network.

For more information, please contact your local sales representative or contact Continental Access directly at (631) 842-9135.

A or B
RS422 to Panels

A Napco Security Group Company

Door Lock
Continental Instruments,Power
A Napco
Supply Security Group CompanyG • 355 Bayview Ave., Amityville, NY 11701
Phone (631) 842-9400 • Fax (631) 842-9135
Continental
Instruments llc

Requestwww.cicaccess.com
to Exit
Motion Detector
GSA GS-07F-00039H
G CardAccess® and CI SQL 3000TM are trademarks
Door Lock of Continental/NAPCO, 2007 A480B
Door Contact G Door Contact

G G
Request Request

You might also like