Relay Relay: Protection Relay Protection Relay
Relay Relay: Protection Relay Protection Relay
Relay Relay: Protection Relay Protection Relay
XJ3
NJB1-S NJBK10 Phase-Failure and
Time Delay Motor Protection Phase-Sequence
Relay Relay Protective Relay
Control Relay
NJBK7 NJBK6
Motor Protection Motor Protection
Relay Relay NJS1-H NJS1-M
Time Delay Relay Time Delay Relay
NJBK1 NJBK2
Series Motor Motor NJS1 NJS5
Protection Relay Protection Time Delay Relay Time Delay Relay
Relay
NJBK5 NJBK5-5
Motor Controller Motor Controller
NJS5-M2 NJS3
Time Relay Time Delay Relay
NKG1 KG10D
General Purpose Relay
Time Switch Time Switch
NJX-13FW NJDC-17
Miniature Miniature Power
Power Relay Relay with test
button
Page G-82 Page G-84
KG10M KG316T
Time Switch Time Switch
JQX-13F JZX-22F
Miniature Miniature
High-power Power Relay
Electromagnetic
Relay
Page G-86 Page G-87
NJJ6 NJJ5-J
Counting Relay Electronic Counter
NJDC-12 JQX-10F
Miniature Power Miniature
Relay with test Power Relay
button
Page G-89 Page G-93
NJJ5-L NJJ3
Electronic Timer Counting Relay
JTX JMK
Miniature Miniature
Power Relay Power Relay
NJJ1 JDM15G
Counting Relay Counting Relay
NJMC1 Power Relay
Pulse Relay Socket Series
JDM1-48 JDM3
Counting Relay Electronic
Counter
1. General PWR
NJB1-YW Floatless Relay is applicable for water level automatic E2-E3
control in industrial facilities & equipments, civil water tower,
E1-E2
high cistern, underground conservation pool, etc.
The control of automaitic water supply or drainage may be
achieved by a simgle operation of the function switch without 0N
RY: SW1
modifying the user's connectiong conditons.
This product is not applicable for water level control of 0FF
2. Type designation
A1
N JB 1 - YW/□ ~ A2
E3
Rated voltage of control power supply E2
E1
Function code: floatless relay 14 11
E1 12
Design sequence No. E2
E3
Relay
Company code
22.5±0.22
102max
109max
Relay
Company code
3. Technical data
Type NJB1-X
Three-phase
Unbalance rate: 2%~22%
unbalance Operation
Unbalance
(0.1~30)s adjustable
NJB1-X Relay (Three-Phase Operation time
22.5max
G
102 max
114max
N L1 L2 L 3
power supply
shares with
the rated input
voltage
Input
L1
L2 N
L3
14 11
Output
12
Load
4. Wiring diagram
Powersupply
L1 L2 L3 shareswith
theratedinput
voltage
Input
L1
L2
L3
14 11
Output
12
Load
Protection)
1. General
NJB1-X1 relay (phase sequence, phase failure protection) is
used as an phase sequence and phase failure protection device
in control circuits with an AC voltage of 200V~500V and a L1 L2 L3
114max
frequency of 50Hz to make and break the circuit. It cannot R
动作
2. Type designation
NJB1-X1
N JB 1 - X1
102max
15 18 16
22.5max
Function code:
X1: phase sequence, phase failure relay
Design sequence No.
3. Technical data
Type NJB1-Y
Protection mode Over-voltage protection, under-voltage protection
DC24V; AC220V,
NJB1-Y Single-Phase Operating voltage
AC110V, AC24V, 50Hz
Voltage Relay Operation Setting Range 10%~100% of max rated input value
Operation time 0.1s~30s adjustable
1. General
NJB1-Y single phase voltage relays (hereinafter the relay for Repeating precision ±10% of operation value
short) are applied in AC 220V, 110V, 24V, frequency 50Hz Time error ±10% of set value
(or 60Hz) and DC 24V control circuits as single phase over- Input frequency 40Hz~500Hz
voltage protection or under-voltage protection and indication
Contact number 1 Switching
elements, making or breaking circuits as intended operating
values and time. Contact capacity Ue/Ie:AC-15 220V/0.75A,120V/1.5A;Ith:3A
The product are in compliance with requirements of Mechanical Endurance ≤10,000,000 times
standard IEC 60947-5-1 Electrical Endurance Making 50,000times, breaking 30,000times
Installation mode Track and Bolts
2. Type designation
N JB 1- Y /□□ 4. Wiring diagram
NJB1-Y
Rated voltage of control power supply
Voltage specification (see table 1) Single-phase power supply G
Function code Operation
power supply
A1
Y: voltage monitoring
A2
V1
Design sequence No. Input
V2 COM
V3
Relay Output
14 11
12
Company code
Load
22.5max
102max
114max
(+)
(~) A1 18 16
(-) A2 15
(~)
102max
NJB1-S Time Delay Relay
109max
1. General
NJB1-S series time relay is suitable for being as the time
control and indicator elements in the control circuit with NJB1-S
the AC frequency of 50Hz/60Hz, rated control supply voltage
to 380V and DC control supply voltage to 24V, to connect or
break off the circuit at a predetermined time.
NJBI-S time-delay relay is used in controlling circuit as time 35
delay element to make or break circuit according to preset time.
7.5
2. Type designation
27
N JB 1 - □/□
Use TH35-7.5 steel mounting rail for Installation
Type NJB1-S
Delay precision 5% T T T
Output T T T T
Company code
3. Operating conditions
3.1 Altitude: not exceed 2000m;
3.2 the surrounding air temperature of -5 ° C - +40 ° C, and
NJBK10 the average value within 24h does not exceed +35 ° C;
3.3 atmospheric conditions: the highest temperature of
Motor protection relay +40 ° C, relative air humidity not exceeding 50%, lower
temperatures can be allowed to have a higher
1. General relative humidity, for example, air humidity up to 90% at
+20° C, and special measures should be taken against the
NJBK10 series motor protection relay (hereinafter referred condensation occasionally due to temperature changes;
to as the protector) suitable for AC 50Hz, rated insulation
3.4 Pollution level: 3;
voltage up to 690V and under, rated working current 1A-
3.5 Mounting surface and the vertical gradient of not more
200A long-term or intermittent AC motor work overload,
than ± 5 °;
open-phase, three-phase imbalance protection. Product
3.6 In medium without danger of explosion and medium
meets IEC60947-4-1 standard requirements
gas not enough to corrode metal or destroy insulation and
where much conductive dust exist;
3.7 Places with anti-rain and snow equipment and not full
of water vapor;
3.8 in the absence of significant shake, shock and vibration;
3.9 Installation Category: Ⅱ;
3.10 Electromagnetic Environment: A;
3.11 Casing protection grade: IP20. G
4.1 Main circuit: Rated insulation voltage AC690V Rated frequency 50Hz, rated operating current of 1A-200A.
Table 1
Model Rated current specification Rated current range A Suitable for motor power kW
4.2 Auxiliary circuit: Rated insulation voltage AC380V Rated frequency 50Hz, auxiliary contacts parameters
Table 2
5. Structural characteristics
5.1 Double-row LED display, the upper row of LED displays running current, bottom row of LED displays set current, the
indicator lights indicate the operating status and fault status;
5.2 Features overload given time protection (on/off), inverse time overload protection, open-phase, three-phase current
unbalance protection function;
5.3 Built-in 4 overload curves are available to meet different occasions;
5.4 Panel with start and stop buttons, terminal block can be external connected with start and stop buttons with simplified
wiring;
5.5 Auto-start function can open the auto-start function and set the start-up delay. In case of power resumption or reset
after power failure, the protector start automatically as per the set auto start delay, free of any human intervention;
5.6 Fault memory and its indications: In case of motor failure, the indicator displays the fault type, while the bottom row LED
flashes and displays the fault code;
5.7 Mouning mode: screw mounting.
6. Protection characteristics
6.1 Inverse time operation characteristic
When the current value exceeds the 1.1 times the set current value, the protector will start the inverse overload protection
function. The protector shall simulate the calculation of the motor heat accumulation and movement time according to the
overload current multiples. When the heat accumulation reaches a certain value, the protector acts to cut off the AC
contactor, so as to protect the motor.
The relationship between the overload current and the time are shown in Table 3, Figure 1.
Overload multiple
M ax Ii - Iavg
3
Where:
Ii - Each phase current RMS
Iavg - Three-phase current average
100min
50min
20min
10min
5min
2min
1min
50s
20s Kr=5
10s Kr=4
5s Kr=3
Kr=2
2s
1s
1 2 5 8
×Iset
Time - current characteristic curve
When definite time function is open, set definite time overload magnification and definite time time, if the running current ≥ set
overload current × magnification and exceeds the set definite time, the protector shall act, as shown in Figure 2.
lds
lset
t2
t1
7. Wiring diagram
7.1 Control power voltage AC220V wiring diagram in Figure 3 Control power voltage AC380V wiring diagram in Figure 4.
L3 L2 L1 N
FU1
Stop Start
QS
W1 V1 U1
KM
FU1
W2 V2 U2 A1 A2 96 95 98 +12V
KM
W3 V3 U3
QF1 NJBK10 motor protection relay
QF1 AC220V
W4 V4 U4
M
3~
L3 L2 L1
FU1
Stop Start
QS
FU1
W1 V1 U1
KM
FU2
W2 V2 U2 A1 A2 96 95 98 +12V
KM
W3 V3 U3
QF1 NJBK10 motor protection relay
QF1 AC380V
W4 V4 U4
M
3~
65max
25 Running NJBK10
current
motor protection relay
Set
Start Stop
current
Reset Set up
Running Set Break Overload Unbalanced
35
phase
142.5±0.29
156max
9. Ordering information
9.1 Description and model specifications of the protector, the control supply voltage (AC220V, AC380V) selected according to the
requirements for use.
Setting current range (1A-10A, 5A-50A, 20A-200A);
9.2 Ordering Quantity.
Specification code:50,200,800
1. General
NJBK7 series motor protection relay (hereinafter referred to
as protector) is used to provide overload, locked rotor, phase 3. Operating conditions
failure, three-phase current unbalance, ground and PTC
temperature protection for AC motors with a frequency of 3.1 Altitude: should not exceed 2000m;
AC 50Hz, a rated insulation voltage of up to 690V and a 3.2 Ambient tempeature: -5℃~+40℃, and the average
rated operational current of 1A-800A that operate temperature in 24h should not exceed +35℃;
continuously or intermittently. The protector uses flexible 3.3 Atmospheric conditions: The relative air humidity should not
Rogowski coil to acquire current and features wide setting exceed 50% at the maximum temperature of +40℃. The
current range, high accuracy and convenient installation. relative humidity may be higher at lower temperatures, for
The protector has RS485 interface and 4mA-20mA analog example, the air humidity can be up to 90% at +20℃. Special
transmission interface, permits network communication and measures should be taken if condensation occurs on the product
can realize remote monitor and control and fault inquiry of occasionally due to temperature variation;
motors by means of upper computer. The protector is 3.4 Pollution degree: 3;
genenrally used in combination with AC contactor. 3.5 The inclination between the mounting plane and the vertical
Standards: IEC 60947-4-1. plane should not exceed ±5°;
3.6 In non-explosive media that do not contain a sufficient
amount of gas or conductive dust to cause metal corrosion or
insulation failure;
3.7 In places with rain and snow protection equipment and not
full of vapor;
3.8 In places where there is no significant shake, impact or
vibration;
3.9 Mounting category: Ⅲ;
3.10 Degree of protection of enclosure: IP20.
Model Setting current (A) Setting current range (A) Matching motor power (kW)
4.2 Auxiliary circuit: rated insulation voltage: AC380V, rated frequency: 50Hz, data of auxiliary contact
Usage category AC-15
Rated operational voltage Ue(V) 240 380
Rated operational current Ie(A) 1.5 0.95
Conventional heating current Ith(A) 5
L1 L2 L3 N
L1 L2 L3 N
QF
SB2 SB1KM2 KM3 KA
QF
KM2
SB2 SB1 KM1 KA KM3KM2
KM1 KM1 KM2
KM1 KM1
KA KA
KM1
CT 1 2 3 4 5 6 7
1 2 3 4 5 6 7 CT A1 A2 07 08 98 95 96
A1 A2 07 08 98 95 96
10 C1NJBK7 Motor protection relay
NJBK7 Motor protection relay 11 C2
T1 T2 PE
10 C1 12 13 8 9 14
11 C2 PE
T1 T2
12 13 8 9 14 KM3 M 4mA~20mA
θ
3~
4mA~20mA
M
θ
3~
KM2
Figure 2 Secondary current direct starting connection diagram in 7. Overall and mounting dimensions (mm)
case the control supply voltage is 220V and the rated operational NJBK7-50 overall mounting dimensions
voltage is 220V
L1 L2 L3 N
QF
R
83max
M.Over P.fail P.Unbl M.Stal
48.5max
RST L2
KM1 L3 L1
MD
CT
1 2 3 4 5 6 7 96.5max
A1 A2 07 08 98 95 96 94.5max
NJBK7 Motor protection relay 113max
10 C1
11 C2 T1 T2 PE
12 13 8 9 14
M 4mA~20mA
θ
3~
57.6±0.5
79.6±0.5
diagram in case the control supply voltage is 220V and the rated
operational voltage is 220V
32.5max
L1 L2 L3 N 62.5±0.5
QF
SB2 SB1 KM2 KA
KA KA
KM2 1 2 3 4 5 6 7
CT A1 A2 07 08 98 95 96
108max
R
48.5max
L3 L1
11 C2 T1 T2 PE MD
96.5max
M 4mA~20mA
θ
115.5max
3~ 113max
57.6±0.5
79.6±0.5
93max
32.5max
84.5±0.5
RST
MD
96.5max
113max
130.5max
152±0.5
175max
G
115max
92±0.5
93max
Frame size
Company code
3. Operating conditions
3.1 Altitude: should not exceed 2000m;
3.2 Ambient tempeature: -5℃~+40℃, and the average
temperature in 24h should not exceed +35℃;
NJBK6 3.3 Atmospheric conditions: The relative air humidity should not
exceed 50% at the maximum temperature of +40℃. The
Motor Protection Relay relative humidity may be higher at lower temperatures, for
example, the air humidity can be up to 90% at +20℃.
1. General Special measures should be taken if condensation occurs on the
NJBK6 series motor protection relay is used to provide product occasionally due to temperature variation;
overload, phase failure, three-phase current unbalance and 3.4 Pollution degree: 3;
locked rotor protection for AC motors with a frequency of 3.5 The inclination between the mounting plane and the vertical
AC 50Hz, a rated insulation voltage of below 690V and a plane should not exceed ±5°;
rated operational current of 1A~36A that operate 3.6 In non-explosive media that do not contain a sufficient
continuously or intermittently. amount of gas or conductive dust to cause metal corrosion or
Standards: IEC 60947-4-1 insulation failure;
3.7 In places with rain and snow protection equipment and not
full of vapor;
3.8 In places where there is no significant shake, impact or
vibration;
3.9 Mounting category: Ⅲ
4. Technical data
4.1 Main data and technical characteristics
No. Setting current range Model of matching contactor Matching motor power
4.2 Technical data of main circuit 4.4 Technical data of auxiliary circuit
Rated operational current: 1A~36A, Control supply voltage: AC 220×(1±10%)V,
rated insulation voltage: 690V, rated frequency: 50Hz; AC 380×(1±10%)V; Rated frequency: 50Hz;
4.3 Technical data of control circuit 4.5 Operating characteristics
Number of contacts: 1 group of change-over contacts; 4.5.1 The operating characteristics of overload protection
Contact capacity: Ue/Ie: AC-15 380V/0.95A, 240V/1.5A; are given in Table 2
Ith: 5A; Rated frequency: 50Hz;
.
Setting current
No. Operation time Starting conditions Starting conditions
multiple
1 1.05 No operation within 2h Cold state +20℃
2 1.2 Operation within 2h Hot Start +20℃
3 1.5 Operation within 2min Hot Start +20℃
4 7.2 2s<Tp≤10s Cold state +20℃
M3ax I i -I avg
i=1 ×100%>30%
Iavg
Hereinto:
Ii- Effective value per phase current
Iavg- Mean value of the three phases of currents
4.5.4 Operating characteristic of latching protection
The latching current of the protector is set as 6Ie. When the main circuit current is larger than the latching current, the protector will
deferthe actuation, and its actuation time is 3s and its relative error is ±20%.
4.6 Reset characteristics
After the operation of the protector, if the control supply voltage is normal, the protector can be reset manually; if the control supply
voltage is off, the protector resets immediately.
5. Connection diagram
The connection diagrams in case the control supply voltage is AC220V and AC380V are shown in Figure 1 and Figure 2.
L3 L2 L1 N L3 L2 L1 N
Figure 1 Figure 2
FU1 FU1
QS QS
W1 V1 U1 W1 V1 U1
KM KM
FU2 FU2
95 A1 95 A1
W2 V2 U2 W2 V2 U2
KM QF1 KM QF1
W3 V3 U3 STP ST W3 V3 U3 STP ST
96 A2 96 A2
QF1 QF1
W4 V4 U4 KM W4 V4 U4 KM
M M
3~ 3~
18 30
/
6.3 Commissioning: After checking the connection and setting,
T R
88max
12 36
FAULT RUN A
NJBK6-36
switch on the power supply and operate the start button. The
motor should run normally and the (green) running
indicator on the protector panel should light up. If the red
indicator flashes, finely adjust the setting value until the red
indicator stops flashing.
2. Type designation
N JBK 1 - □/□ □
Frame size: 80
Design serial number
Motor protector
Enterprise characteristic code
4.2 Auxiliary circuit: Rated insulation voltage: AC380V; rated frequency: 50Hz; use category, rated working voltage, rated operating
current and conventional thermal current.
5. Structure characteristic
5.1 Structure characteristic
5. 1.1Knob setting current value and trip grade.
5.2 LED displays the current value, setting state, fault code and other information about the maximum phase.
5.3 With overload inverse time-lag protection, open-phase protection, three-phase current unbalance protection and other functions.
5.4 5 optional built-in overload curves,meet the use at different occasions.
5.5 Test / Reset: Operating status, press "Test / Reset" button for a short time to conduct simulated action test, and press it for a long time
to enter setup mode; press this button to reset under fault conditions.
5.6 Pluggable terminal blocks, facilitate user connection.
5.7 Integrated design, simple structure, two installation methods of guide rail installation and screw mounting.
5.8 Fault memory and its instruction. In case of motor failure, LED flashes alternately and displays the fault code and maximum phase
current value.
6. Protective characteristics
6.1 Overload operating characteristics
Overload multiple
Action 1.05 1.2 1.5 2 5 6 7.2 Remark
G
Overload
curve time (s)
Kr=1 No action 63 40 22 3.6 2.5 1.8 Conform to Level 5
Kr=2 No action 125 80 45 7.2 5 3.5 Conform to Level 10A
Kr=3 No action 250 160 90 14 10 6.9 Conform to Leve l 10
Kr=4 No action 500 320 180 29 20 14 Conform to Leve l 20
Kr=5 No action 750 480 270 43 30 21 Conform to Leve l 30
100min
50min
20min
10min
5min
2min
1min
50s
20s Kr=5
101max
10s
Kr=4 2 / T 1 4 / T 2 6 / T 3
5s Kr=3
Kr=2
3×Φ16
2s
Kr=1
1s 125max
1 2 5 8
×Iset
7. Wiring diagram
Control power supply voltage AC220V wiring diagram 10 3
10A 20 2 4
73max 5 30
1 5
脱扣 等级 电流(A)
过载 脱扣 等级 设定
断相 电流 设定
长按3s
不平衡 A相电流 测试
设置——运行
测试 B相电流 复位
L3 L2 L1 N C相电流
NJBK1电动机保护器
FU1
113±0.29
QS
W1 V1 U1
KM
FU1
W2 V2 U2 A1 A2 98 95 08 07 9. Ordering information
KM
W3 V3 U3
9.1 Name and type specification of protector
QF1 NJBK1-80 motor protector Select the control power supply voltage (AC220V, AC380V)
QF1 AC220V
according to the operating requirements
W4 V4 U4
Setting current range (1A~5A, 2A~10A, 6A~30A,16A~80A)
M
3~ 9.2 Order quantity
L3 L2 L1
FU1
QS
FU1
W1 V1 U1
KM
FU2
W2 V2 U2 A1 A2 98 95 08 07
KM
W3 V3 U3
QF1 NJBK1-80 motor protector
QF1 AC220V
W4 V4 U4
M
3~
Supply voltage
Specification of rated current
3. Operating conditions
3.1 Altitude ≤2000m.
3.2 Ambient air temperature -5℃ ~ +40℃, with daily average
≤+35℃.
3.3 Atmospheric condition: when the highest temperature is
+40℃, relative humidity of air shall be no more than 50%,
higher relative humidity shall be allowable at lower temperature.
The max monthly average relative humidity of the most humid
month shall be not more than 90% and the lowest monthly
average temperature of the same month should be no more
than +25 ℃, condensed dew on surface of the product due to
NJBK2 Motor the change of the temperature should be taken into account.
3.4 Pollution Level: Level 3.
Protection Relay 3.5 Installation Category: Ⅲ.
1. General 3.6 Inclination between installation plane and vertical plane shall
≤±5°.
NJBK2 series motor protection relay (hereinafter referred to
3.7 At places without prominence rock, impact and vibration.
protector as simply) is applicable for overload, locked-rotor,
3.8 At places without explosive risk, without gases that may be
phase-failure, three phase current unbalance, earthing and
corrosive to metal or gases that may cause damage to the
PTC temperature protection of AC motor @ A.C.50Hz, less
insulation, and with little conducting dust
than 690V rated insulation voltage and 2A ~ 800A rated
3.9 At places where rain & snow proof facilities are equipped
operating current for its continuous working or
with and not being full of steam.
discontinuous working.
This product meets the requirements of IEC 60947- 4-1 4. Technical data
4.1 Main circuit: rated insulation voltage AC690V, rated frequency
50Hz.
Rated Setting current Suitable motor
Type
current (A) range (A) power (kW)
NJBK2-200/10
NJBK2-200/50
10
50
2~10
10~50
1~5
5~25
G
NJBK2-200/200 200 40~200 20~100
NJBK2-400/400 400 160~400 80~200
NJBK2-800/800 800 320~800 160~400
5. Design features
5.1 Equipped with functions of overload, locked-rotor, phase-
failure, three-phase unbalance, earthing and PTC temperature
protection etc.
5.2 Six indicators indicate status of power supply, operation,
phase-failure (three phase unbalance), overload, earthing and
temperature, respectively. Equipped with function of fault
memory.
5.3 four kinds of trip class
5.4 Digital dial-up settings with high precision.
5.5 Three kinds of reset modes: manual reset, remote manual
reset and automatic reset
6. Protection characteristics
6.1 Operation characteristics under three-phase balanced-load status
Times of Ambient
S.N. Trip class Operation time Test condition
setting current temperature℃
10A
10
1 1.05 <2h non-tripping Start from cold status
20
30
10A
10
2 1.2 <2h tripping Start right after Item No.1 20±2
20
30
10A <2min
10 <4min
3 1.5 Start right after Item No.1
20 <8min
30 <12min
10A 2s<tp≤10s
10 4s<tp≤10s
4 7.2 Start from cold status
20 6s<tp≤20s
30 9s<tp≤30s
120min
100min 6.5 Protection feature of pre-buried PTC thermistor in motor:
PTC thermistor protection is carried out by detecting resistance
50min value of thermistor output from PTC detector pre-buried in
stator winding or bearing of motor and taking it as protection
20min condition to judge whether motor is overheating, when PTC
reaching reacting resistance value, reacting delay<1s.
10min
PTC protection
5min
2min
1min
50s Ω Tripping delay PTC tripping
Tripping reset
20s 3000
30
10s 20 1650
1600
10
5s
10A
2s
t
1s PTC temperature alarm Alarm clearance
1 2 5 8
×Ie
7. Wiring diagram
7.1 Wiring diagram for control power supply @ AC220V/AC230V voltage
68max
61.5max
Wiring diagram for control power supply @ AC220V/AC230V voltage 6/T3 4/T2 2/T1
L1
L2
L3
N
66.4±0.32
S1
S2 2×φ5.5
K1M K1M
Reset
A1 A2 95 96 97 98 Y1 Y2
K1M
C1 N J B K2-X
71.4±0.23
C2
86.5max
A
COM B
C
C COM
COM
CT C
B
B
A
A
T1 T2
M 2×R2.75
3~ 97±0.26
Top view
7.2 Wiring diagram for control power supply @ AC380V/AC400V voltage 9.2 Overall and mounting dimensions of NJBK2-200 macropore
transformer
Wiring diagram for control power supply @ AC380V/AC400V voltage
L1
L2
L3
N 26
92max
S1
83max
36
S2
K1M K1M Reset
A1 A2 95 96 97 98 Y1 Y2
K1M
C1
C2
COM
86
COM C
CT C
B B 147max
A
A
118
T1 T2
G
M
3~
70max
60
8. Accessory instruction
S.N. Designation Quantity Remarks
It is suggested to be used 9.3 Overall and Amounting dimensions of NJBK2-400 transformer
1 NJBK2-200 conductive bar 3 when main circuit current is
within the range of 80A-200A.
30
2 NJBK2 wire holder 2 Instrument installation
3 NJBK2 clamp 1 Instrument installation
104max
30
128
193max
11.5
6.5
81max
60 ±0.3
64±0.3
Top view
79 ±0.5
40
121max
40
65 ±0.5
164
247max
11.5 6.5
35.5
95max
26max
Top view
65max
A1 A2 95 96 97 98 Y1 Y2
NJBK2-200
88±0.26
95max
35±0.19
RESET TEST
CURRENTSETTING TRIP
T1 T2 C1 C2 COM C B A
71max
Function code
Blank: with liquid level relay
D: without liquid level relay
10: frame size code
Motor controller
Company code
3. Operating conditions
3.1 Altitude: the altitude of the mounting location should not
exceed 2000m;
3.2 Ambient temperature: -5℃~+40℃, and the average
NJBK5 Motor Controller temperature in 24h should not exceed +35℃;
3.3 Atmospheric conditions: The relative air humidity at the
mounting location should not exceed 50% at the maximum
1. General
temperature of +40℃. The relative humidity may be higher at
NJBK5 series motor controller (hereinafter referred to as
lower temperatures. Special measures should be taken if
controller) is mainly used in circuits with a frequency of AC
condensation occurs on the product occasionally due to
50Hz (or 60Hz), a rated operational voltage of up to 380V
temperature variation;
and a rated control power of up to 11kW (current up to
3.4 Pollution degree: 3;
22A) to control the direct start and stop of water pumps or
3.5 Mounting category: Ⅲ;
motors, provide motors with overload and phase failure
3.6 In places where there is no significant vibration or impact;
protection, and realize automatic liquid level control for
3.7 In non-explosive media that do not contain a sufficient
civil water towers and reservoirs.
amount of gas or dust to cause metal corrosion or insulation
This product is not applicable to the liquid level control of
failure;
low-conductivity liquids, such as oil, purified water,
3.8 In places where rain and snow protection is provided;
inflammable and explosive chemical liquids and high-
3.9 The inclination from the vertical plane should not exceed 5°.
density sewage.
Standards: IEC 60947-4-1.
NJBK5-10 0.72A~2.4A
2.4 1.1 0.55 CJX2-1210 JD-8/0.5A~5A 0.72~2.4 5
NJBK5-10D 0.72A~2.4A
NJBK5-10 3.5A~11A
12 5.5 3 CJX2-1210 JD-8/2A~20A 3.5~11 1
NJBK5-10D 3.5A~11A
NJBK5-10 10A~16A
16 7.5 4 CJX2-1810 JD-8/2A~20A 10~16 1
NJBK5-10D 10A~16A
NJBK5-10 20A~25A
25 11 5.5 CJX2-2510 JD-8/20A~80A 20~25 1
NJBK5-10D 20A~25A
Setting current
No. Operation time Starting conditions
multiple
1 1.05 No operation within 2h Cold state start
2 1.2 Operation within 2h Start after No.1
3 1.5 Tripping class 30 ≤12min Start after applying a 1.0 times setting current for 2h
4 7.2 Tripping class 30 9s<Tp≤30s Cold state start
5. Features
The controller consists of a CJX2 series AC contactor, a JD-8 series motor comprehensive protector and an NJB1-YW1 liquid level relay
in a protective enclosure and is divided into two types, with liquid level relay and without liquid level relay. Products with liquid level relay
are used to control the start and stop and automatic pumping and drainage of water pumps and provide overload and phase failure
protection. Products without liquid level relay are used to control the start and stop of motors and provide overload and phase failure
protection.
Setting of the motor comprehensive protector in the controller is required before it is connected and put into use.
6. Wiring diagram
a. Connection diagram of NJBK5-10 in case both the control b. Connection diagram of NJBK5-10 in case the main circuit
circuit voltage and the main circuit voltage are AC380V voltage is AC380V and the control circuit voltage is AC220V
L1 L2 L3 L1 L2 L3 N
FU FU
11 14NO 11 14NO
JD-8 JD-8
NJB1-YW1 NJB1-YW1
ST ST
14 13NO KM 14 13NO KM
U V W U V W
M M
3~ 3~
L1 L2 L3
FU
1/L13/L2 5/L3 A1
STP
KM KM
A2
2/T1 4/T2 6/T3
96
JD-8 14NO
JD-8
95 ST
13NO KM
U V W
M
3 ~
L1 L2 L3 N
FU
96
JD-8 14NO
JD-8
95 ST
13NO KM
U V W
3~
M
G
2×Φ6
START
PUMP
NJBK5-10
FULL MOTOR CONTROLLER R
NJBK5-10
162±0.5
198max
0.72A-2.4A
3.5A-11A
ZHEJIANGCHINTELECTRICSCO.,LTD.
10A-16A
20A-25A
Rated Control Supply Voltage Us
OVERLOAD 50HzAC220V
50HzAC380V
△
ZHEJIANGCHINTELECTRICSCO.,LTD.
60.8±0.5
127max
118max
Motor controller
Company code
3. Operating conditions
3.1 Altitude: the altitude of the mounting location should not
exceed 2000m;
3.2 Ambient tempeature: -5℃~+40℃, and the average
NJBK5-5 Motor Controller temperature in 24h should not exceed +35℃;
3.3 Atmospheric conditions: The relative air humidity at the
mounting location should not exceed 50% at the maximum
1. General temperature of +40℃. The relative humidity may be higher at
NJBK5-5 motor controller (hereinafter referred to as lower temperatures. Special measures should be taken if
controller) is mainly used in circuits with a frequency of AC condensation occurs on the product occasionally due to
50Hz/60Hz, a rated operational voltage of up to 220V and temperature variation。
a rated control power of up to 2.2kW (current up to 20A) 3.4 Pollution degree: 3;
to control the direct start and stop of single-phase water 3.5 Mounting category: Ⅱ;
pumps, provide overload and underload protection (pump 3.6 In places where there is no significant vibration or impact;
runaway protection), and realize automatic liquid level 3.7 In non-explosive media that do not contain a sufficient
control for civil water towers and reservoirs. amount of gas or dust to cause metal corrosion or insulation
This product is not applicable to the liquid level control failure;
of oil, purified water, inflammable and explosive chemical 3.8 In places where rain and snow protection is provided;
liquids, corrosive liquids and high-density sewage. 3.9 The inclination from the vertical plane should not exceed 5°.
Standards: IEC 60947-4-1
Setting current
No. Operation time Starting conditions
multiple
1 1.05 No operation within 2h Cold state start
2 1.2 Operation within 2h Start after No.1
3 1.5 ≤4min Start after applying a 1.0 times setting current for 2h
4 7.2 4s<Tp≤10s Cold state start
4.5.2 Operating characteristics of underload protection (pump runaway protection): When the actual operational current of the pump
motor is less than 20%~100% of the rated current of the motor, the red “Fault” indicator of the controller flashes and, after a delay of
60s±10s, the controller stops operation.
4.5.3 Protection return characteristics: After the operation of the overload or underload protection (pump runaway protection) of the
controller, the controller restarts automatically after a delay of 30min±3min.
4.5.4 Reset characteristics: power-off reset, the reset time ≤ 1min.
4.6 Down-lead distance of liquid level control electrode: 500m max.
4.7 Requirements for the liquid under control: general domestic water or high-conductivity sewage.
4.8 Mounting type: installation type.
N L
Power Liquid level
Neutral Live supply Motor electrode
wire wire
L N N L E3 E2 E1
QF
High
Pool Medium
Low
M
~
6 60
4 8 40 80
2 10 20 100
Overload setting (A) Underload setting (%)
4×Φ6
NJBK5-5
FORCED START
NJBK5-5 MOTOR CONTROLLER
111±0.29
146max
Standard IEC60947-4-1
Rated operating current Ie
2A~10A
4A~20A
Rated Power Pe
ZHEJIANGCHINTELECTRICSCO.,LTD.
0.25kW~1.1kW
0.55kW~2.2kW
Rated Control Supply Voltage Us
50HzAC220V POWER
ZHEJIANGCHINTELECTRICSCO.,LTD.
61±0.2
84max 96max
Supply voltage
5. Design features
5.1 Three-phase electronic type, trip class is level 10A, 10, 20
G
and 30.
Code of setting current
5.2 Equipped with function of phase-failure, overload and three-
Derived code phase unbalance protection.
5.3 Digital dial-up setting with high precision
Design consequence number
5.4 Digital current display.
Integrated motor protector 5.5 Three indicators indicate normal, overload and phase-failure
(three-phase current unbalance) status respectively.
5.6 Main circuit adopts feed-through wiring.
5.7 Installation mode: bolts
6. Protection features
6.1 Operation characteristics under phases balanced-load status
(see Table 3)
6.2 Operation characteristic under phase-failure status
Operation characteristic under phase-failure status should meet
the requirement: operation time of protector ≤5s
3
Max - Ii-Iavg
i=1
×100%>40%
Iavg
Where:
Ii---The r.m.s value of each phase
Iavg---The average current of thee-hase current
120min L3 L2 L1 N
100min
FU1 H3 H2 H1
50min
QS Protector
FU2
W1 V1 U1
20min STP ST 96 95 A2 A1
10min
W2 V2 U2
5min KM
KM KM
W3 V3 U3
2min QF1
10s 20
QS Protector
Fu2
Ambient W1 V1 U1
Trip Operation Test
S.N. I/In STP ST 96 95 A2 A1
class time condition temperature
10A
W2 V2 U2
10 <2h non- KM
start from KM KM
1 1.05
20 tripping cold status W3 V3 U3
30 QF1
10A 2s<Tp≤10s
113max
64max
30 9s<Tp≤30s 113±0.42
126max
6.4 Reset mode: De-energizing reset
JD-5A/400
7. Wiring diagram
7.1 See Figure 2 for wiring diagram of control power supply @
AC220V/AC230V voltage.
135max
R
66max
142.5±0.29
156max
9. Ordering information
9.1 Designation and type-specification of protector, select
controlling current and voltage (AC220V, AC230V, AC380V,
AC400V ), setting current range (1A~5A, 5A~20A, 20A~80A,
80A~200A, 160A~400A), Trip class (10A, 10, 20, 30)
according to operating requirements. Trip class in routine order
is level 10.
9.2 Order Quantity.
JD- 5 E / □ □
3. Operating conditions
3.1 Altitude ≤2000m
3.2 The ambient air temperature is -5℃ ~+40℃ and the
JD-5E Integrated Motor average temperature within 24h shall not exceed +35℃ .
3.3 Atmospheric condition: Relative humidity of
Protector atmosphere shall not exceed 50% at the temperature of
+40℃ ,and higher relative humidity is allowed at lower
1. General temperature. For example, the air humidity can reach 90%
at the temperature of +20℃ . Regarding the condensation
JD-5E Integrated Motor Protector is applicable to
casually caused by humidity change, special measures shall
overload and phase failure protection of AC motor
be taken.
working for a long time or discontinuously with AC
3.4 Class of pollution: Class III
50Hz, rated insulation voltage AC690V and rated
3.5 Installation category: category III
working current 1A-400A. The protector is usually
3.6 The angle between the installation surface and the
matched with the AC contactor for use. It conforms to
vertical surface shall not exceed ±5 degrees.
IEC 60947-4-1 standards.
3.7 The place without obvious shake, impact and vibration
shall be selected as the installation site.
3.8 The installation site shall conform to the following
standards: explosive and dangerous medium, no gas
capable of corroding and damaging insulation in the
medium and less conductive dust in the medium
3.9 The place with rain-proof and snow-proof equipment
and a little water vapor shall be used as the installation
G
site.
4.2 Auxiliary circuit: rated insulation voltage AC380V, rated frequency 50Hz (shown in Table 2)
Table 2
Utility Category AC-15
Rated operating voltage (V) 240 220 380
Rated operating current (A) 1.5 1.5 0.95
Conventional thermal current (A) 5
5. Others
5.1 Structure characteristics
5.1.1 Three-phase electronic type
5.1.2 Function of phase failure and overload protection
5.1.3 Device capable of continuously adjusting setting current
5.1.4 Three indicating lights respectively indicate the working states of phase failure, operation and overload.
5.1.5 The main circuit adopts pass-through-core type wiring method.
5.1.6 Installation method: installation via screws
5.2 Protective characteristics
5.2.1 The operating characteristics of the protector during load unbalance of each phase are shown in Table 3.
10A
30
10A
10 Actuation within 2h
2 1.2 Operation following
20 sequence 1
30
20±2
10A <2min
10 <4min
3 1.5 Operation following
20 <8min sequence 1
30 <12min
10A 2s<tp≤10s
10 4s<tp≤10s
4 7.2 Start from cold state
20 6s<tp≤20s
30 9s<tp≤30s
50 min
20 min
10 min
5 min
2 min
1 min
50 s
20 s
30
10 s 20
5s 10
10 A
2s
1s
1 2 5 8
×I e
L3 L2 L1 N
L3 L2 L1
FU1 H3 H2 H1
QS Protector
FU2
W1 V1 U1
STP ST 96 95 A2 A1
W2 V2 U2
KM Each phase more than 1A feedthrough by three times
KM KM
W3 V3 U3
QF1
L3L2L1
L1, L2, L3: three-phase power supply
W4 V4 U4 KM: Contactor
M A1, A2, 95, 96: Number of protector connection terminal
3 ~ STP: Stop button
ST: Start button
FU1, FU2: Fuse protector Each phase below 1A feedthrough by three times
G
QF1: Motor protector
L3 L2 L1
L3 L2 L1 N
FU1 H3 H2 H1
QS Protector
FU2
W1 V1 U1
STP ST 96 95 A2 A1
Each phase more than 1A feedthrough by three times
W2 V2 U2
KM
KM KM L3 L2 L1
W3 V3 U3
QF1
L1, L2, L3: three-phase power supply
KM: Contactor
W4 V4 U4 A1, A2, 95, 96: Number of protector connection terminal
STP: Stop button
M ST: Start button Each phase below 1A feedthrough by three times
3 ~ FU1, FU2: Fuse protector
QF1: Motor protector
113±0.29
110max
φ12
64max
整定电 流
JD-5E 电动机保护器
断相 运行 过载
2×φ5.6
126.5max
JD-5E/400
142.5±0.29
133max
25
R
65max
JD-5E
10A 80
0 120
10
20
16
30
电动机综合保护器
200
35
脱扣级别 整定电流
断相 运行 过载
156max
7. Ordering information
7.1 Designation and type-specification of protector, select controlling current and voltage (AC220V, AC380V),
setting current range (1A~5A, 5A~25A, 20A~80A, 80A~200A, 160A~400A), according to operating requirements.
7.2 Order Quantity.
3. Operating conditions
3.1 Altitude ≤2000m.
3.2 Ambient temperature Range: -5℃ ~ +40℃, with daily
average ≤ +35℃.
3.3 Atmospheric condition: when the highest temperature is
+40℃, the relative humidity of air shall be no more than 50%,
higher relative humidity shall be allowable at lower temperature,
for instance air humidity may reach 90% at +20 ℃. As for dews,
which contigently appear due to change of temperature, special
steps should be taken.
JD-5 Motor Integrated 3.4 Pollution Level: Level 3.
3.5 Inclination between installation plane and vertical plane shall
Protector ≤±5°.
3.6 In the media without explosive risk, and no gases that may be
1. General corrosive to metal and damage insulation in the media together
JD-5 Motor Integrated Protector (hereinafter referred to as with at places where much conducting dust being in existence.
protector) is applicable for overload and phase-failure 3.7 At places where rain & snow proof facilities are equipped
protection of AC motor @ A.C.50Hz, less than AC690V with and not being full of steam.
rated insulation voltage and 0.5A~400A rated operating 3.8 At places without prominence rock, impact and vibration.
current for its continuous working or discontinuous 3.9 Installation Category: Ⅲ.
working. Protector and AC contactor are generally used
cooperatively. 4. Technical data
This product meets the requirements of IEC 60947- 4-1. 4.1 Rated insulation voltage AC690V, rated frequency 50Hz,rated
operating current 0.5A ~ 400A.
Table 1
Setting current Voltage of control power Suitable motor
Type
range (A) supply (Supply Voltage) (V) power (kW)
JD-5/80
JD-5/80
JD-5/80
0.5~5
2~20
20~80
220V, 230V, 380V, 400V
220V, 230V, 380V, 400V
220V, 230V, 380V, 400V
0.25~2.5
1~10
10~40
G
JD-5/400 80~200 220V, 230V, 380V, 400V 40~100
JD-5/400 160~400 220V, 230V, 380V, 400V 80~200
JD-5(with
1~80 220V, 230V, 380V, 400V 0.5~40
buzzer)
5. Design features
5.1 Three-phase electronic type, tripping grade (trip class): 10A.
5.2 Equipped with function of phase-failure and overload
protection.
5.3 Equipped with continuously adjustable device for setting
current.
5.4 Three indicators indicate normal, overload and phase-failure
status respectively.
5.5 Main circuit adopts feed through wiring.
5.6 Installation mode: use bolts for installation.
20s
6.2 Operation characteristic under phase-failure status (see Table 4)
10s
Table 4
5s
Multiple of setting current 1s
operating Test Ambient 1 2 3 4 5 6 7
S.N. Any two The Third
time Condition temperature ×Ie
phases phases
1 1.0 0.9 <2h non-tripping Cold Status 6.4 Reset mode: de-energizing reset
+20℃
2 1.15 0 ≤5s Hot Status
7. Wiring diagram
7.1 Wiring diagram for control power supply @ AC220V/AC230V
voltage
L3 L2 L1 N
FU1 H3 H2 H1
L3 L2 L1
QS Protector
FU2
W1 V1 U1
STP ST 96 95 A2 A1 Circles of the cable: once (more than 3A)
W2 V2 U2
KM
KM KM
W3 V3 U3 L3 L2 L1
L1, L2, L3: three-phase power supply
QF1 KM: Contactor
A1, A2, 95, 96: Number of protector connection terminal
Circles of the cable: twice every phase
STP: Stop button
(less than 3A)
W4 V4 U4 ST: Start button
FU1, FU2: Fuse protector
M
QF1: Motor protector
3~
L3 L2 L1 N
FU1 H3 H2 H1
L3 L2 L1
QS
FU2 Protector
W1 V1 U1
STP ST 96 95 A2 A1 Circles of the cable: once (more than 3A)
W2 V2 U2
KM
KM KM
W3 V3 U3
L3 L2 L1
QF1 L1, L2, L3: three-phase power supply
KM: Contactor
A1, A2, 95, 96: Number of protector connection terminal Circles of the cable: twice every phase
W4 V4 U4 STP: Stop button (less than 3A)
φ12
126max
95 96 A1 A2
64max
JD-5
MOTOR INTEGRATEDPROTECTOR
2s-30s X-Y
φ5.5
Start delay Current setting
Phase-failure Running Overload
113±0.42
JD-5/400
25max
133max
35max
156max
R
66max
JD-5
MOTOR INTEGRATEDPROTECTOR
2s-30s
Start delay
X-Y φ5.5
Current setting
Phase-failure RunningOverload
142.5±0.29
9. Ordering information
9.1 Designation, type and specification of protector, select
controlling current and voltage (AC220V, AC230V, AC380V,
G
AC400V ), setting current range (0.5A~5A, 2A~20A,
20A~80A, 80A~200A 160A~400A, etc) according to
operating requirements.
9.2 Order Quantity.
3. Operating conditions
3.1 The altitude shall not exceed 2000m.
3.2 The ambient air temperature is -5℃~+40℃ and the
average temperature within 24h shall not exceed +35℃.
3.3 Atmospheric condition: Relative humidity of
atmosphere shall not exceed 50% at the temperature of
+40℃,and higher relative humidity is allowed at lower
temperature. For example, the air humidity can reach 90%
at the temperature of +20℃. Regarding the condensation
JD-8 Integrated Motor casually caused by humidity change, special measures shall
be taken.
Protector 3.4 Class of pollution: Class III
3.5 Installation category: category III
1. General 3.6 The angle between the installation surface and the
vertical surface shall not exceed ±5 degrees.
JD-8 Integrated Motor Protector is mainly applicable
3.7 The place without obvious shake, impact and vibration
to fault protection of overload and phase failure of
shall be selected as the installation site.
low-voltage three-phase AC asynchronous motor in
3.8 The installation site shall conform to the following
electric power system with AC frequency 50Hz and
standards: explosive and dangerous medium, no gas
rated insulation voltage less than 690V. The protector
capable of corroding and damaging insulation in the
is usually matched with the contactor in AC motor
medium and less conductive dust in the medium
loop circuit for use. It conforms to IEC 60947-4-1
3.9 The place with rain-proof and snow-proof equipment
standards.
and a little water vapor shall be used as the installation
site.
4. Technical data
4.1 Main circuit: rated insulation voltage AC690V,
rated frequency 50Hz
0.5~5 0.25~2.5
2~20 1~10
JD-8 20~80 10~40
32~80 16~40
64~160 32~80
Serial number Multiple of setting current Actuation time Starting condition Ambient air temperature
1 1.05 No actuation within 2h Cold state
2 1.2 Actuation within 2h Hot state (the test is done Room temperature
3 1.5 Actuation within 12min following sequence 1) (20±5)℃
4 7.2 9s<tp≤30 s Cold state
L1 L2 L3 N
L1 L2 L3
ST ST
FU STP
95 96 FU STP
95 96
KM KM
KM KM
FU
KM FU
KM
JD-8
JD-8
M
M
95 96
66±0.43 φ12
G
68max
A B C Overload
Current setting
52
R2.2 91max
JD-8(32A~80A,64A~160A)
95 96
96±0.5
φ20
76max
L1 L2 L3
57max
FU
JD-8 MOTOR INTEGRATED PROTECTOR
KM KM
FU
A B C Overload
Current setting M
80
R3.5
125max
7. Ordering information
7.1 The protector with proper type number and specification shall be selected according to the use requirement.
7.2 Order quantity
NJYB3 Relay
1. General
NJYB3 relay is used to provide overvoltage, undervoltage,
phase failure, phase sequence and three-phase unbalance
control in three-phase three-wire 380V circuits and three-
phase four-wire 220V circuits with a frequency of AC
50Hz/60Hz. For example, it is used for power control
systems, air conditioning systems and motors.
This relay is a voltage protection relay. After detecting the
voltage signal, the relay processes the input signal, judges
if there is an overvoltage, undervoltage, phase failure,
error-phase or unbalance and controls the operation
accurately and stably by means of the built-in
microprocessor.
3. Technical data
Overvoltage
Three-phase
Undervoltage
0.1s~10s three-wire system: Ue/Ie:AC-15
NJYB3 Three-phase
AC 380V 50Hz/60Hz 220V/0.75A,
voltage unbalance 1Z 105 106
380V/0.47A;
Three-phase Ith:3A
Phase failure,
≤1s four-wire system:
phase sequence
AC 220V 50Hz/60Hz
Ph ase Ph ase
Three-ph ase Three-ph ase Si ng le- ph ase/ Overvol tage Und ervol tage Unb al an ce
Model sequ en ce fai lure
three- wire four -wire tw o-ph ase protecti on protecti on protecti on
protecti on protecti on
NJYB3-1 ● ● ●
NJYB3-2 ● (1.05~1.3)×Ue ●
NJYB3-3 ● (0.7~0.95)×Ue ●
NJYB3-4 ● (1.05~1.3)×Ue (0.7~0.95)×Ue ●
NJYB3-5 ● (1.05~1.3)×Ue (0.7~0.95)×Ue ● ●
NJYB3-6 ● (1.05~1.3)×Ue (0.7~0.95)×Ue Fixed 20% ● ●
NJYB3-7 ● Fixed 120%×Ue Fixed 80%×Ue 5%~15% ● ●
NJYB3-8 ● (1.05~1.3)×Ue (0.7~0.95)×Ue 5%~15% ● ●
NJYB3-9 ● ● (1.05~1.3)×Ue ●
NJYB3-10 ● ● (0.7~0.95)×Ue ●
NJYB3-11 ● ● (1.05~1.3)×Ue (0.7~0.95)×Ue ●
NJYB3-12 ● (1.05~1.3)×Ue (0.7~0.95)×Ue ● ●
NJYB3-13 ● (1.05~1.3)×Ue (0.7~0.95)×Ue Fixed 20% ● ●
NJYB3-14 ● Fixed 120%×Ue Fixed 80%×Ue 5%~15% ● ●
NJYB3-15 ● (1.05~1.3)×Ue (0.7~0.95)×Ue 5%~15% ● ●
NJYB3-16 ● ● ●
Immunity
4. Wiring diagram
NJYB3-1, NJYB3-2, NJYB3-3, NJYB3-4, NJYB3-5,
NJYB3-6,NJYB3-7, NJYB3-8 Wiring diagram
NJYB3-12, NJYB3-13, NJYB3-14, NJYB3-15, NJYB3-16
Wiring diagram G
L1 L2 L3 L1 L2 L3 N
14 11 12 14 11 12
KM KM
KM KM L1
L1
L2
L2 L3
L3 N
L1 L2 L3 N
Three-phase
14 11 12
L1
L2
L3
N
Two-phase
L1 L2 L3 N
L1
L2
N
One-phase
L1 L2 L3 N
L1
N
45.5max
66.2max
35.8±0.3 35±0.2
91max
7.6
5.6
3.9
2.5
OFF
1. General
9.9
This product is used in AC 50Hz three-phase four-wire
8.4
220V circuit to control the overvoltage,under-voltage,phase
7.3
failure,phase sequence.
6.3
5.6
4.9
2. Type designation 4.4
Design No.
Voltage protection
Relay
G
0.8 0.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 Un
Corporation Code
Note: 0.8Un is the preset normal voltage protection range, when delaying, it is 9.9s.
2.2 Technical parameters
2.2.1 Fundamental parameter
3. Wiring diagram
a. Overvoltage protection: (1.0-1.3) Ue; undervoltage
protection: (0.7-1.0) Ue. Wiring diagram for voltage protector
b. Fault protection time: 0.1~9.9s.
c. Dielectric strength: there is no breakdown and flicker
N A B C
appeared for alternating current (50Hz) lasting a period of A
time of 1 s. under 2000V.
d. Insulation resistance: >100M (relative humidity at 20℃ FUI
is 90%). QFI
KM STP
e. Contact capacity: AC-15 220V 1A.
C Ta
f. Contact resistance: 0.03Ω. B Tb
g. Contact life: life should ≥100, 000times. A Tc
STP
h. Ambient temperature: -10℃~ +50 ℃. N
i. Ambient humidity: ≤8% (20℃±5℃). KM Tb
j. Installation mode: 35mmlC guide rail installation
Ta
2.3 Performance feature
KM
Load
2. Type designation
N JYB 5
Design number
Relay
3. Function
Table 1 Function table
5. Protection characteristic
5.1 Overvoltage protection the normal indicating light goes out and the normally opened
contact of the relay is opened. When the unbalance voltage
G
When the voltage of any phase at the supply end exceeds the
operating value of the overvoltage, of the load end is more than the operating value of the
the overvoltage/under-voltage/recovery indicating light will unbalance, the unbalance indicating light flashes;
flash at the speed of 1 time per second; after the delay time when the delay time runs out, the normal indicating light goes
runs out, the normal indicating light goes out and the out and the normally opened contact of the relay is opened.
normally opened contact of the relay is turned on. When the unbalance voltage values of the supply end and the
When the highest voltage value of the supply end is less than load end are less than the voltage value of resetting unbalance,
the resetting voltage value, the recovery indicating light goes the unbalance indicating light goes out and the
on; after the recovery time runs out, the normal indicating overvoltage/under-voltage/recovery indicating light goes on
light goes on and the normally opened contact of the relay continuously; when the delay time runs out, the normal
will be closed. indicating light goes on and the normally opened contact of
5.2 Under-voltage protection the relay is closed.
When the voltage of any phase at the supply end is lower than 5.4 Phase sequence protection
the under-voltage operating value, L1-L2-L3 is positive sequence, while L1-L3-L2 is negative
the overvoltage/under-voltage/recovery indicating light will sequence. When the voltage phase sequence of the supply
flash at the speed of 0.5 times per second; after the delay time end is wrong, the phase dislocation indicating light goes on;
runs out, the normal indicating light goes out and the normally the normal indicating light goes out and the normally opened
opened contact of the relay is turned on. When the lowest contact of the relay is opened; when the phase sequences of
voltage value of the supply end is more than the resetting the supply end recovers to the positive sequence, the phase
voltage value, the overvoltage/under-voltage/recovery dislocation indicating light goes out;
indicating light goes on continuously; after the recovery time the overvoltage/under-voltage/recovery indicating light goes
runs out, the normal indicating light goes on and the normally on continuously; the normal indicating light goes on and the
opened contact of the relay will be closed. normally opened contact of the relay is closed.
5.3 Unbalance protection of three phases
The voltage value of unbalance is equal to the difference
between the highest voltage value and the lowest voltage
value. When the unbalance voltage of the supply end is
more than the operating value of unbalance, the unbalance
indicating light goes on; when the delay time runs out,
35±0.2
44.7max
70.4max
83max
L1 L2 L3 12
断相
正常 不平衡 错相 过压/欠压/恢复
1.15 1.20
75.2±0.8
1.10 1.25
过压
1.05 1.30
欠压
×U e
0.80 0.85 恢复
0.75 0.90 Ue :380V
11 14 La Lb Lc
L1 L2 L3 12 12 11 14
11 14 La Lb Lc
KM KM
L1
Load
L2
L3
Company code
NJXB3 Relay
1. General
NJXB3 relay is used as an overvoltage, undervoltage,
phase failure, phase sequence, three-phase voltage
unbalance and PTC temperature protection device in three-
phase three-wire control circuits with an AC voltage of
380V and a frequency of 50Hz/60Hz and three-phase four-
wire control circuits with an AC voltage of 220V and a
frequency of 50Hz/60Hz to make and break the circuit.
NJXB3-1 ● (1.05~1.3)×Ue ●
NJXB3-2 ● (0.7~0.95)×Ue ●
NJXB3-3 ● (1.05~1.3)×Ue (0.7~0.95)×Ue ●
NJXB3-4 ● (1.05~1.3)×Ue (0.7~0.95)×Ue ● ●
NJXB3-5 ● (1.05~1.3)×Ue (0.7~0.95)×Ue Fixed 20% ● ● ○
NJXB3-6 ● Fixed 120%×Ue Fixed 80%×Ue 5%~15% ● ● ○
NJXB3-7 ● (1.05~1.3)×Ue (0.7~0.95)×Ue 5%~15% ● ● ○
NJXB3-8 ● ●
NJXB3-9 ● ● ● ●
NJXB3-10 ● ● ●
NJXB3-11 ● ● (1.05~1.3)×Ue ●
NJXB3-12 ● ● (0.7~0.95)×Ue ●
NJXB3-13 ● ● (1.05~1.3)×Ue (0.7~0.95)×Ue ●
NJXB3-14 ● (1.05~1.3)×Ue (0.7~0.95)×Ue ● ●
NJXB3-15 ● (1.05~1.3)×Ue (0.7~0.95)×Ue Fixed 20% ● ● ○
NJXB3-16 ● Fixed 120%×Ue Fixed 80%×Ue 5%~15% ● ● ○
NJXB3-17 ● (1.05~1.3)×Ue (0.7~0.95)×Ue 5%~15% ● ● ○
NJXB3-18 ● ● ● ○
3. Technical data
Overvoltage
Three-phase
Undervoltage
0.1s~10s three-wire system:
Ue/Ie:AC-15
Three-phase
AC 380V 50Hz/60Hz
voltage unbalance 220V/0.75,
1Z 105 106
NJXB3 380V/0.47A;
Phase failure, Three-phase
phase sequence Ith:3A
≤1s four-wire system:
PTC temperature AC 220V 50Hz/60Hz
protection
4. Wiring diagram
NJXB3-1, NIXB3-2, NJXB3-3, NJXB3-4, NJXB3-10 NJXB3-5(P), NJXB3-6(P), NJXB3-7(P),NJXB3-8(P), NJXB3-9
Wiring diagram Wiring diagram
L1 L2 L3 L1 L2 L3
Three-phase
12 11 14 R1 R2 12 11 14 R1 R2
KM KM KM PTC
KM
L1 L1
L2 L2
M
L3 L3
L1 L2 L3 N
L1 L2 L3 N R
断相
76max
75.2±0.8
动作 过欠压 错相 不平衡
1.15 1.20 4 6
1.05 1.30
?áUe t(s)
0.80 0.85
0.75 0.90
0.70 0.95 5
?áUe Asm(%)
12 11 14 R1 R2 NJXB3-17
35±0.2
12 11 14 R1 R2
L1 70.4max
44.7max
83max
L2
L3
N
6. Installation and use
6.1 Connect the wires correctly in accordance with the
connection diagram.
6.2 If the relay is of rail mounting type, use TH35-7.5 mounting
Two-phase rail.
6.3 If the relay is of installation mounting type, remove the
L1 L2 L3 N
limiter.
L1
L2
N
One-phase
L1 L2 L3 N
N
L1
G
L1 L2 L3 N
12 11 14 R1 R2
KM KM PTC
L1
L2
M
L3
N
Note: in the example diagram for application circuit, protective relay can provide protection only under the condition of phase-failure
occurring at terminal 1, 2, 3 and among three phase of power supply A, B, C.
4. Wiring diagram
XJ3-G, S wiring diagram XJ3-D wiring diagram
A B C L1 L2 L3 L1
FU1
FU 4 5
3 6
XJ QF1 KM
2 7 ST
1 8 L3 Ta
Tb
Start Stop L2 Tc
XJ
STP
KM Power 7 8 L1
XJ supply KM Ta
KM
KM 5 6
Tc
KM
Load
Load L2
110max
2×φ4.5
54.5±0.4
≥90
85max
35.5
8×φ4
46max
9 15.5
2×φ5
115max
70.5max
60.2
35.4
45.5max
Mode NJS1-H
Operating mode On-delay (OND, OND1), trigger delay (OND2), On-off repetitive delay (FLY), interval delay (INT, INT1), optional
Number of contacts Delay 1 change-over
Contact capacity Ue/Ie: AC-15 220V/0.75A, 380V/0.47A; DC-13 220V/0.27A; Ith:5A
Solid state output NPN solid state delay 1 ouptut
Solid state output capacity Max 30VDC Max 100mA
Operational voltage AC/DC(100~240)V 50Hz/60Hz DC24V
Electrical life 1×105
Mechanical life 1×106
Delay accuracy Start timing from power on: ±0.01%±0.05s, start timing from signal ON: ±0.01%±0.03s
Timing mode Addition or subtraction timing mode, optional
The output contacts have automatic reset function.
Contact output time
The contact ouptut time is 10, 50, 100, 200, 500, 1000, 2000, 5000 or Hold, optional. (unit: ms)
Ambient temperature -5℃~+40℃
Mounting type Panel type
Delay range For single product, 99.99s/999.9s/9999s/99min59s/999.9min/9999min/99h99min/9999h, optional
4. Wiring diagram
OUT
11 12
OUT
30VDC 100mA
1 2 3 4 5
(+) (-)
(~) SOURCE (~)
G
5. Overall and mounting dimensions (mm)
Profile and installation dimension Opening size
65min
59max 97max
+0.5
-0
R
45.5
48.5max
65min
RESET
INT
PAUSE
LOCK OUT RUN
+0.5
SET MD 45.5 -0
NJS1-H TIME DELAY RELAY
Power
INA triggerterminal
INB pauseterminal
t t t
On delay
OUT(output)
settime
0
Settime
0
POWER ON DELAY(counting resets when power OFF)
Power
INA triggerterminal
INB pauseterminal
t a
On delay OUT(output)
settime
0
Settime
0
POWER ON DELAY(counting continues when power OFF)
Power
INA triggerterminal
INB pauseterminal
OUT(output) t t t
Trigger delay settime
0
Settime
0
SIGNAL ON DELAY1(resets when power OFF)
Power
INA triggerterminal
INB pauseterminal
OUT(output)
Loop delay settime
Settime
0
Settime
Settime
0
FLICKER(resets when power OFF)
Power
INA triggerterminal
INB pauseterminal
Settime
0
INTERVAL1(resets when power OFF)
Power
INA triggerterminal
INB pauseterminal
0
Settime
0
SIGNAL OFF DELAY(resets when power OFF)
Delay range
Type 99.99s, 999.9s, 9999s, 99min59s, 999.9min, 9999min, 99h59min, 9999h are optional for each product
4. Wiring diagram
NJS2-M Wiring diagram
Trigger (INA) Pause(INB)
6 7 8 9 10
11 12 OUT
OUT 30VDC 100mA
1 2 3 4 5
( + ) ( - )
( ~ ) SOURCE ( ~ )
97max
+0.5
45.5 0
48.5max
RE ST
45.5+0.5
SE T
0
1N B
45
LOCK OU T CR RU N
REST MD
59max
Power supply
INA
INB
Reset
t t t
(power) on delay Output (OUT)
settime
0
settime
Trigger (INA)
pause (INB)
Reset
t t a t-a
Trigger (INA)
pause (INB)
Reset
t t t
Trigger-delay Output (OUT)
settime
0
settime
0
SIGNAL ON DELAY1(Power supply OFF Reset)
Trigger (INA)
pause (INB)
Reset Ton Ta
Toff Tb Ton Toff Ton Toff Ton Toff
Output (OUT)
Circulation-delay
settime
settime
0
settime
settime
0
FLICKER(Power supply OFF Reset)
Trigger (INA)
pause (INB)
Reset
0
settime
0
SIGNAL OFF DELAY(Power supply OFF Reset)
Trigger (INA)
pause (INB)
Reset
Output (OUT)
Interval-delay
settime
settime
Feature code:
No mark: Conversion of delay group I with external
reset and pause functions
2Z: Conversion of delay group II
11: Conversion of delay group II with external reset
and pause functions
K: Conversion of delay group I, and instantaneous group I
S: Conversion of delay group I, cyclical delay
1. General
NJS1 Series Time-Delay Relay is applicable for controlling
circuit @ A.C. 50Hz/60Hz, up to 380V rated voltage or up
to D.C.240V rated voltage as delay element to make or
break circuit according to preset time.
4. Wiring diagram
4 5 Pause Pause
4 5 4 5
3 6 3 6 3 6
Reset Reset
2 7 2 7 2 7
1 8 1 8 1 8
(-) (+) (-) (+) (-) (+)
( ~) ( ~) ( ~) ( ~) ( ~) ( ~)
SOURCE SOURCE SOURCE
Pause
Reset
5
6
7
3
4 5
6
G
4 8
3 9 2 7
2 10 1 8
1 11 (-) (+)
(-) (+) ( ~) ( ~)
( ~) ( ~) SOURCE
SOURCE
NJS1
46max
45.4±0.4
48.5max
OPEN
46max
123max
58max
N JS 5 - □ □ / □
Delay specifications
A: Power on delay
B: Interval delay
Y: Star - Delta Starters delay
M1: power-on delay (multi range type)
Design number
Time relay
3. Technical data
Product Model NJS5-A NJS5-B NJS5-Y NJS5-M1
Work mode Power on delay Interval delay Star - Delta Starters delay Power on delay
AC36V,AC110V,AC220V,AC230V,
Rated control supply voltage AC220V,AC380V AC380V
AC380V,AC400V,DC24V
Number of Contacts Delay 1 CO Delay 2 NO Delay 1 CO
Star - delta conversion time 20ms ~ 300ms (adjustable)
Contact capacity Ue/Ie:AC-15 220V/0.75A, 380V/0.47A; DC-13 220V/0.27A; Ith:5A
Electrical life 3×104 1×105
Mechanical life 1×106
1s, 10s, 1min, 10min, 1h, 10h, 1d, 10d
Delay specifications 5s,10s,30s,60s,2min,3min,5min,10min,20min
(multi range type, adjustable)
Ambient temperature -5℃~+40℃
Installation Guide rail
18.5max 65max
ON
36.4±0.5
100.6±1
107max
延时 10 s
5 7
3
9
1 10
时间继电器
NJS5-A
18.5max 65max
ON 3
5
R
9
G
100.6±1
107max
1 10
36.4±0.5
100 200
20 300ms
延时 10 s
时间继电器
NJS5-Y
18.5max 65max
A1 A2
ON 5 7
3
9
100.6±1
1 10
107max
36.4±0.5
1h 10h
10min 1d
1min 10d
10s ON
1s OFF
NJS5-M1
16
15 18
Design number
Time replay
NJS5-M2time relay
1. General
NJS5-M2 time relay mainly applies to control circuits
with 50Hz/60Hz AC rated control supply voltage to 400V
and DC rated control supply voltage to 24V as time
control element, to connect or disconnect circuit by
scheduled time.
3. Technical data
On-delay, off-delay, interval delay, off-delay/interval delay, equal period cyclical delay
Working mode
(ON start),equal period cyclical delay (OFF start), Trigger/interval delay, 7 adjustable gears
Rated control supply voltage AC110V,AC220V,AC230V,AC240V,AC380V,AC400V,DC24V
~
+
A1 Y1 16 18
A2 15
-
~
18.5max
65max
A1 A2
Function
ON W
C Di
107.5max
H D
A B
102±1
90.5mmax
5 7
36.4±0.5
3
Time 9
1 10
10min
100s 100min
Range
10s 10h
1s 100h
NJS5-M2
Y1 16
15 18
N JS 3 - □ /□
Design Code
3. Technical data
L 3 L 3
N 4 N 4
L
L
N
N
N L N 4
L 3
4 3
18.5max 65max
G
36.4±0.5
100.6±1
107max
10
5 15
0.5
0 20
NJS3
L 3
N 4
4. Wiring diagram
N A1 A2 L
1 2
2. Type designation
18.5max 65max
N JS 3 - D/□
电源
100.6±1
延时
107max
36.4±0.5
运行
Company code 2 A2
6. Timing-sequence diagram
A1-A2
t t t
OUT
LED
L(+)
N(-)
N L
NTE8 Time Delay Relay
A B
1. General
NTE8 Series time delay relay is applicable for controlling
circuit @AC 50Hz/60Hz, up to 230V rated voltage or up to
DC 24V rated voltage as delay element to make or break Figure 3 NTE8-□B Relay wiring diagram
circuit according to preset time.
This product meets the requirements of IEC60947-5-1. L(+)
N TE 8 - □ □
Operating mode: A2 B2
A: control-off delay; B: (power) on delay
A1 B1
Delay range
86max
67max
35
7.5
27
4. Wiring diagram
JSS48B Wiring diagram
JSS48B Time Delay Relay Pause Reset
4 5
1. General 3 6
(-) (+)
(~) Source (~)
2. Type designation
JSS 48 B - □
5. Overall and mounting dimensions (mm)
Pated control supply voltage Profile and installation dimension of JSS48B series products
Derived code
60max
Design sequence No.
Time Delay Relay
52max
Opening size
45.5
45.5
4. Wiring diagram
JSS48A Wiring diagram JSS48A-2Z, JSS48A-G, JSS48A-P Wiring diagram
4 5 4 5
3 6 3 6
Pause Reset
2 7 2 7
1 8 1 8
( ) (+)
( ) (+) (~) (~)
(~) Source (~) Source
Pause
4 5
Reset 6
5 7
3 6
4 8 Pause Reset
3 9
2 7
2 10
1 11 1 8
(-) (+)
( ) (+) (~) Source (~)
(~) Source (~)
59max 45.5
49max
45.5
JSS48A
8 8 S 8 8
124max
A: (0.05-0.5)s/5s/30s/3min
(0.1-1)s (0.1-1)s
B: (0.1-1)s/10s/60s/6min (0.1-1)s (0.5-6)s/60s
(0.5-5)s (0.5-5)s
C: (0.5-5)s/50s/5min/30min (0.5-5)s (1-10)s/10min
(1-10)s (1-10)s
Delay range D:(1-10)s/100s/10min/60min (1-10)s (2.5-30)s/30min
(2.5-30)s (2.5-30)s
E: (5-60)s/10min/60min/6h (2.5-30)s (5-60)s/60min
(5-60)s (5-60)s
F:(0.25-2)min/2min/2h/12h (5-60)s
(10-180)s (10-180)s
G:(0.5-4)min/40min/4h/24h
Set mode Potentiometer
AC50Hz/60Hz, 36V, 110V, 127V, AC50Hz/60Hz, 36V, AC50Hz/60Hz AC110V AC220V AC36V,AC110V 50Hz/60Hz AC36V,AC110V 50Hz/60Hz
Operating
AC220V AC230V AC380V AC400V 110V, 127V AC220V AC230V AC230V AC380V AC400V AC220V AC230V AC380V AC220V AC230V AC380V
voltage
DC24V AC380V AC400V DC24V DC24V AC400V DC24V AC400V DC24V
Delay precision ≤10% ≤10% ≤10% ≤10% ≤10%
Contact Delay 2 switching, delay 1 changeover, Delay 1 switching or Delay 1 Delay Delta 1 Delay 1
number instantaneous switching delay 2 switching switching switching switching
Contact capacity Ue/Ie: AC-15 220V/0.75A, 380V/0.47A; DC-13 220V/0.27A;Ith:5A
Electrical Endurance 1×105
Mechanical Endurance 1×10
6
4. Wiring diagram
JSZ3A JSZ3C JSZ3F
External reset signal
4 5 4 5 4 5
3 6 3 6 6
3
2 7 (+) 2 7 (+)
( ) ( ) ( ) 2 7 (+)
(~) (~) (~) (~) (~) (~)
1 8 1 8
1 8
( ) (+) ( ) 2 7 ( ) 2 7 (+)
2 7 (~) (~) (~)
(~) (~)
1 8 1 8
1 8 (+)
(~) AC220V DC24V
AC220V DC24V
AC220V DC24V Source Source
Source
UP
54.5max
35
51max
φ
ON
58.5max 10max
41max
84max
51max
58.5 12.5max
41max
86.5max
Opening size
32
4×φ4.5
54.8
50
44
34
(-)
2. Type designation 1 5 9 13 (~)
JS Z 6 - □
JSZ6-4
Integrated type 3 7 11
(-)
13 (~)
1 5 9
22.5max 66max
Opening size
Time switch
Company code
3. Technical data
Working mode
Manual switch and automatic switch; switching time can be adjusted automatically by latitude
Daylight saving time function (optional)
G
Programmable quantity 8-on 8-off
Time control range 1min~ 24h
Timing error ≤2s/day
82max
R
ON
NKG3
MD
Power AC220V
3 4
R
36max 68.6max
Load AC220V
R
ON
MD
NKG3
KM
35.4±0.28
88.8max
Power AC220V
3 4
ON
MD
R
Figure 5 Connection diagram of three-phase control (contactor
NKG3
coil: 380V)
ON MD R
Load AC380V
Load AC220V
L1
L2
L3
N KM
3 4
R
ON
MD
NKG3
Time switch
Company code
3. Technical data
R
Figure 2 Connection diagram of single-phase expansion control
(contactor coil: 220V)
97max
82max
R
ON
MD
NKG3-M
Power AC220V
3 4
36max 68.6max R
Load AC220V
R
ON
MD
NKG3-M
KM
35.4±0.28
88.8max
Power AC220V
3 4
ON
MD
R
Figure 5 Connection diagram of three-phase control (contactor
coil: 380V)
NKG3-M
Load AC380V
Load AC220V L1
L2
L3
N KM
3 4
R
ON
MD
NKG3-M
3. Wiring diagram
3.1 Wiring for direct control mode: direct control mode can be
used for electrical apparatus which is single-phase power supply
and its power consumption doesn't exceed rated value of this
switch. See Figure 1 for wiring method;
3.2 Wiring for single-phase dilatancy mode: it is required a AC
contactor with larger capacity than electrical apparatus power
consumption for dilatancy when the controlled electrical
NKG1 Time Switch apparatus is single-phase power supply, whereas its power
1. General consumption exceeds rated value of this switch. See Figure 2 for
NKG1 Time Switch is control element with time as wiring method;
control unit and can automatically turn on or turn off 3.1.3 Wiring for three-phase operation mode: if the controlled
power supply of various consumer equipments according electrical apparatus is three-phase power supply, it is required to
to preset time by user. The controlled objects are circuit externally connect three-phase AC contactor.
equipments and household appliances such as street a. See Figure 3 for wiring, control contactor @ AC220V coil
lamps, neon lamps, advertising lamps, manufacturing voltage, 50Hz;
equipments, broadcast & television equipments, etc., which b. See Figure 4 for wiring, control contactor @ AC380V coil
requires turning on and off at definite time. voltage, 50Hz
Figure 1
Power
Load
supply
SOURCE LOAD
L N N L
G
NKG1
Figure 2
Power
Load
supply
KM
SOURCE LOAD
L N N L
NKG1
A
B Load
C
N KM
SOURCE LOAD
L N N L
NKG1
Figure 4
A
B Load
C
N KM
SOURCE LOAD
L N N L
NKG1
72.43max
45.32max
3×φ3.5±0.10
107±0.29
117.57max
35.5±0.28
62.7±0.23
3. Wiring diagram
KG10D Time Switch 3.1 KG10D-1H is 1 NO and see Figure 4 for wiring method;
3.2 KG10D-1Z is 1 NO/ 1 NC and see Figure 3 for wiring
1. General method;
KG10D Time Switch can automatically turn on or turn off 3.3 Wiring for single-phase direct control mode: direct control
power supply of various consumer equipments according mode can be used for electrical apparatus which is single-phase
to preset time by user. The controlled objects are circuit power supply and its power consumption doesn't exceed rated
equipments and household appliances such as street value of this switch. See Figure 1 for wiring method;
lamps, neon lamps, advertising lamps, manufacturing 3.4 Wiring for three-phase operation mode: if the controlled
equipments, broadcast & television equipments, etc., which electrical apparatus is three-phase power supply, it is required to
requires turning on and off at definite time. externally connect three-phase AC contactor. See Figure 2 for
wiring method for control contactor @ AC220V coil voltage,
50Hz.
Figure 1 single-phase load
KG10D-1H
G
Power AC220V
Load AC220V
KG10D-1H
N KM
Load AC380V
AC contactor
1 2 3 4 5
Power
Figure 4 KG10D-1H
1 2 3 4 5
Power
1 2 3 4 5
51.5max 73.5max
3. Wiring diagram
Wiring diagram
KG10M Time Switch
1. General
KG10M Time Switch can automatically turn on or turn off
power supply of various consumer equipments according 4 5
to preset time by user. The controlled objects are circuit
3 6
equipments and household appliances such as street
lamps, neon lamps, advertising lamps, manufacturing 2 7
equipments, broadcast & television devices etc. Which
1 8
requires turning on and off at definite time.
POWER
G
WED
51.5max
OFF
59.5max 122.5max
Opening size
45.5
45.5
3. Function features
3.1 "AAA” size battery, replaceable;
3.2 Max set times per day (8 opens & 8 closes, 16 opens & 16
closes) and select according to requirements;
3.3 On-off time may cycle according to day or week;
3.4 Equipped with keyboard locking function for error operation
protection;
3.5 Adopt single key operation in all, easy to install and adjust;
3.6 Timing error ≤2s/day.
4. Wiring diagram
KG316T Time Switch
4.1 Wiring for direct control mode: direct control mode can be
1. General used for electrical apparatus which is single-phase power supply
KG316T Time Switch can automatically turn on or turn off and its power consumption doesn't exceed rated value of this
power supply of various consumer equipments according switch. See Figure 1 for wiring method;
to preset time by user. The controlled objects are circuit 4.2 Wiring for single-phase dilatancy mode: it is required a AC
equipments and household appliances such as street contactor with larger capacity than electrical apparatus power
lamps, neon lamps, advertising lamps, manufacturing consumption for dilatancy when the controlled electrical
equipments, broadcast & television equipments, apparatus is single-phase power supply, whereas its power
etc., which requires turning on and off at definite time. consumption exceeds rated value of this switch. See Figure 2 for
wiring method;
4.3 Wiring for three-phase operation mode: if the controlled
electrical apparatus is three-phase power supply, it is required to
externally connect three-phase AC contactor;
a. See Figure 3 for wiring, control contactor @ AC220V coil
voltage, 50Hz;
b. See Figure 4 for wiring, control contactor @ AC380V coil
voltage, 50Hz.
Figure 1
Power
Load
supply
T In T Out
KG316T
Figure 2
A
B Load
C
N KM
T In T Out
KG316T
Power
Load
supply
KM
T In T Out
KG316T
Figure 4
A
B Load
C
N KM
T In T Out
KG316T
Φ7±0.14 Φ4.2±0.12
R
107.9±0.29
121.32max
开 自动 关
KG316T时控开关
取消/恢复 校时 校分 校星期
G
自动/手动 定时 时钟
电源 动作
2×R2.1±0.10
63.4±0.37 50.77max
74.73max
3. Technical data
4. Wiring diagram
6 7 8 9 10
12VDC 30mA
11 12
1 2 3 4 5
45.5
97max
58max
R
48max
45.5
复位 设置
NJJ6 计数继电器
INA
INB
Count at INA rising edge,
5 stop counting at INB input.
4
3
Count value 2
1
0
INB
Count at INB input
5
4 falling edge at INA input.
Count value 3
2
1
0
INA
INB INA上升沿计数,
Count at INA rising edge,
G
n
n-1
INB输入停止计数。
n-2 stop counting at INB input.
n-3
Count value n-4
n-5
*n Preset value
Subtraction counting mode
D
INA
INB
Count at INB input
n
n-1
INA输入时,
n-2
falling edge at INA input.
INB输入下降沿计数。
n-3
n -4
Count value n -5
*n Preset value
INA
INA
INA
Output
Plus counting mode Minus counting mode Inverse counting mode A, B, C
mode
t t t t t t
t t t t t t
3. Technical data
Operating voltage 85%-110% of rated voltage AC50Hz/60Hz AC/DC100V-240V, DC24V
Counting range 0~999999
NJJ5-J Electronic Counter Counting speed 10 times/s or 1000 times/s
1. General Counting mode Addition counting mode
This product adopts microminiature design and is Input signal Contact input, sensor input (NPN type)
applicable for counting in various circuits. Reset mode Panel button reset, external terminal reset
Reset min pulse width 20ms
Counting error ≤±1 time
Current failure memory >10 years
Power consumption About 1.5VA
Installation mode Panel type
Ambient temperature -5℃~+40℃
4. Wiring diagram
NJJ5-J contact signal input
0VDC CP
1 2 3 4 5
12VDC
( ) Power ( ) 30mA
( ~ ) ( ~ )
supply
12VDC
0VDC CP 30mA
1 2 3 4 5
( ) Power ( )
Blue(Blue) Black(Yellow) Brown (Red)
( ~ ) ( ~ )
supply
48max
22.5
24max
NJJ5-J
73max 45
56max
25
42max
NJJ5-J
73max 50
Power supply
Reset
999999
Count value
3. Technical data
NJJ5-L Electronic
Timer Operating voltage
Accumulating time range
85%-110% of rated voltage AC50Hz/60Hz AC/DC100V-240V, DC24V
99999.9h, 99h59min59s, 9999h59min, 9999day23h
1. General
Resetting mode Panel button resetting, external terminal resetting
This product adopts microminiature design and is
Input signal Contact input, sensor input (NPN type)
applicable for accumulating time in various circuits.
Resetting min pulse width 20ms
Accumulative error ≤0.02%
Current failure memory > 10 years
Power consumption 1.5VA approx.
Installation mode Panel type
Ambient temperature -5℃~+40℃
4. Wiring diagram
NJJ5-L contact signal input
Accumulating
0VDC time control Reset
1 2 3 4 5
( ) ( )
( ~ ) Power supply ( ~ )
Accumulating
0VDC time control Reset
1 2 3 4 5
( )
( )
Blue (blue) Black (yellow)
( ~ ) Power supply ( ~ )
12VDC
NPN type sensor
Brown (red)
12VDC
Brown (red)
48max
22.5
24max
NJJ5-L
73max 45
56max
25
42max
NJJ5-L 50
73max
Power supply
Reset
TOP
Accumulative time
0 G
12VDC
INA INB Reset OVDC 30mA Pause Batch reset 88max 97max
8 9 10 11 12 13 14
output
30VDC 100mA
COM OUT Batch output
15 16 17 18 Preset
72max
Bath
setting
Lock
Output Batch Reset Power
output
G
69
69
6. Sequence diagram of counting mode
INA
INB
Count at INA rising edge,
5 stop counting at INB input.
4
3
Count value 2
1
0
INB
Count at INB input
5
4 falling edge at INA input.
Count value 3
2
1
0
INA
INB
n Count at INA rising edge,
n-1
n -2 stop counting at INB input.
n-3
Count value n-4
n-5
*n Preset value
Subtraction counting mode
D
INA
INB
Count at INB input
n
n-1 falling edge at INA input.
n-2
n -3
n -4
Count value n-5
*n Preset value
INA
INA
INA
Output
Plus counting mode Minus counting mode Inverse counting mode A, B, C
mode
Output
Plus counting mode Minus counting mode Inverse counting mode A, B, C
mode
(Q)
Count value
0
Count value
0
Count value
0
G
Output Output Output
t t t t t t
t t t t t t
output
11 12
Output
48max
30VDC 100mA
1 2 3 4 5
97max
(+ ) (- )
Power
(~) (~)
Opening size
G
45.5
45.5
INA
INB
Count at INA rising edge,
5 stop counting at INB input.
4
3
Count value 2
1
0
INB
Count at INB input
5
4 falling edge at INA input.
Count value 3
2
1
0
INA
INB
n Count at INA rising edge,
n-1
n -2 stop counting at INB input.
n-3
Count value n-4
n-5
*n Preset value
Subtraction counting mode
D
INA
INB
Count at INB input
n
n-1 falling edge at INA input.
n-2
n -3
n -4
Count value n-5
*n Preset value
INA
INA
INA
Output
Plus counting mode Minus counting mode Inverse counting mode A, B, C
mode
(Q)
Count value
0
Count value
0
Count value
0
G
Output Output Output
t t t t t t
t t t t t t
3. Technical data
Operational voltage 85%-110% of rated voltage AC50Hz/60Hz AC/DC100V-240V
Electrical life 1×105
Mechanical life 1×10
6
4. Wiring diagram
output
12VDC
INA INB Reset 0VDC 30mA 30VDC 100mA NC
8 9 10 11 12 13 14
15 16 17 18
NO COM NC NO COM
1 2 3 4 5 6 7
88max
69
104max
69
输出
复位
INA
INB
Count at INA rising edge,
5 stop counting at INB input.
4
3
Count value 2
1
0
INB
Count at INB input
5
4 falling edge at INA input.
Count value 3
2
1
0
INA
INB INA上升沿计数,
Count at INA rising edge,
G
n
n-1
INB输入停止计数。
n-2 stop counting at INB input.
n-3
Count value n-4
n-5
*n Preset value
Subtraction counting mode
D
INA
INB
Count at INB input
n
n-1
INA输入时,
n-2
falling edge at INA input.
INB输入下降沿计数。
n-3
n -4
Count value n -5
*n Preset value
INA
INA
INA
Output
Plus counting mode Minus counting mode Inverse counting mode A, B, C
mode
Counting rate:
L: low speed type, 30 times/second
H: high speed type, 200 times/second
JDM1-48 Counting Relay Note: Some models of this product apply to a wide range of
operational voltage. For example, an operational voltage of
1. General AC/DC24V~48V means that it can operate normally within the
JDM1 series counting relay is used as a counting or
voltage range of AC or DC 24V to 48V.
counting control element in control circuits with an AC
frequency of 50Hz/60Hz and a rated control supply
voltage of up to 380V and control circuits with a DC
3. Technical data
rated control supply voltage of up to 240V.
Operational voltage 85%-110% of rated voltage AC50Hz/60Hz AC/DC100V-240V
Electrical life 1×105
Mechanical life 1×106
Output mode 1 group of change-over contacts
Ue/Ie: AC-15 220V/0.75A, 380V/0.47A;
Contact capacity DC-13 220V/0.27A; Ith:3A
Counting digits 4-digit counting relay
Counting rate 30 times/second or 200 times/second
Counting mode
Addition, addition ×10,
addition ×100 (subtraction counting
G
available upon request)
Output mode N
Ambient temperature -5℃~+40℃
Power consumption ≤3VA
Mounting type Panel type (with socket for rail mounting)
Overall dimensions W58×H52×L128mm
Opening size W45.5×H45.5mm
Reset
Power
Conut 4 5
3 6 Reset
Preset
value
2 7
1 8 0
0V
NPN Sensors
Power
( - ) ( + ) Output
( ~ ) ( ~ )
6 Power
5 7 Reset
4 8
Reset
+12VBrown (Red)
3 9 Preset
Conut Black (Yellow) value
( - )
2 10
( ~ )
Power 1 11 0
Blue (Blue)
( + )
( ~ ) 0V
NPN Sensors
Output
58max 128max
52max
JDM1-48
RESET
8 8 8 8 1
45.5
45.5
Counter
3. Technical data
Power supply Internal power supply
JDM3 Battery life Approximately 6 years (25℃)
Reset mode
AC/DC 24V~240V
Panel push-button reset (6-digit), G
external terminal reset (6-digit, 8-digit)
Minimum reset pulse width ≥0.2s
Counting error ≤±1 time
Ambient temperature -5℃~+40℃
Mounting type Panel type
Overall dimensions W48×H24×L52.9mm
Opening size W45×H22.5mm
48max
Input Reset
1 3
52.9max
24max
2 4
LOCK
Input Reset
1 3
0V 2 4 0V
22.5
Input Reset 45
+V 1 3
0V 2 4
Input Reset
+V 1 3
0V 2 4 0V
Input Reset
+
AC/DC 1 3
24V~240V 2 4
Input Reset
+
AC/DC 1 3
24V~240V 2 4 0V
Time accumulator
LCD display
Electronic type
3. Technical data
SC3L Power supply Internal power supply
Electronic Timer Battery life Approximately 6 years (25℃)
AC voltage input
(input impedance:≥4.7kΩ)
AC/DC 24V~240V
G
Panel push-button reset (6-digit),
Reset mode external terminal reset (6-digit & 8-digit)
48max
Input Reset
1 3
52.9max
24max
2 4
LOCK
Input Reset
1 3
0V 2 4 0V
22.5
Input Reset
45
+V 1 3
0V 2 4
Input Reset
+V 1 3
0V 2 4 0V
Input Reset
+
AC/DC 1 3
24V~240V 2 4
Input Reset
+
AC/DC 1 3
24V~240V 2 4 0V
3. Technical data
Type NJYW1-NL1 NJYW1-NL2 NJYW1-BL1 NJYW1-BL2
Operating mode Continuous working
Contact number One group changeover contact
Contact capacity Ue/Ie:AC-15 220V/0.75A, 380V/0.47A; Ith:5A
Operating voltage AC 50Hz/60Hz 36V, 110V/220V, 220V/380V AC 50Hz/60Hz 36V, 110V, 220V, 380V
Control electrode voltage 24V
Conductor length Max 1km Max 2km Max 1km Max 2km
Operating resistance ≤25kΩ
Releasing resistance ≥2kΩ
Response time Reacting: max 80ms; releasing: max 160ms
Ambient temperature -5℃~+40℃
Power consumption <3VA
Installation mode Guide rail type or device type
Wiring diagram for NJYW1-NL1, NJYW1-NL2 Wiring diagram for NJYW1-NL1, NJYW1-NL2
water supply mode 110V/220V water drainage mode 220V/380V
N L L1 L2 L3 N
QS QS
S0 S1 S2 E1 S0 S1 S2 E1
AC110V AC220V
AC220V AC380V
Ta Tc Tb E3 E2 Ta Tc Tb E3 E2
KM KM
KM KM
M M
Wiring diagram for NJYW1-NL1, NJYW1-NL2 wiring diagram for NJYW1-BL1 and NJYW1-BL2
water drainage mode 110V/220V upper/lower water pool level control 220V
N L
N L
QS
QS
Upper water pool
S0 S1 E4 E5 E1
AC220V
S0 S1 S2 E1
AC110V
AC220V Ta Tc Tb E3 E2
M Note: IN NJYW1-BL1 or NJYW1-BL2, Ta,Tc,Tb are not one group of changeover contacts, among which Ta
& Tc are one group of independent normally open contacts; Tc & Tb are one group of normally closed
contacts
Wiring diagram for NJYW1-NL1, NJYW1-NL2 wiring diagram for NJYW1-BL1 and
water supply mode 220V/380V NJYW1-BL2 upper/lower water pool level control 380V
L1 L2 L3 N
L1 L2 L3 N
QS
QS
Upper water pool
S0 S1 E4 E5 E1
S0 S1 S2 E1 AC380V
AC220V
AC380V
Ta Tc Tb E3 E2
Ta Tc Tb E3 E2 KM
Lower water pool
KM
KM
KM
M
Note: In NJYW1-BL1 or NJYW1-BL2, Ta,Tc,Tb are not one group of changeover contacts, among which Ta &
M
Tc are one group of independent normally open contacts; Tc & Tb are one group of normally closed
contacts
45.5max
60.2±0.37
35.4±0.28
3. Technical data
Type JYB-714 JYB-714B JYB-714C
Operating mode Continuous working
Contact number One group of changeover contact
Contact capacity Ue/Ie: AC-15 220V/1.5A; Ith:5A
AC 50Hz/60Hz 36V, 110V, 220V, 380V
Operating voltage
(other voltage can be custom made)
Control electrode
50μA
max current
JYB-714 Floatless Relay Conductor length Max 1km
1. General Ambient temperature -5℃~+40℃
JYB-714 Series Floatless Relay is used in liquid level Power consumption <3VA
automatic control circuit @ AC 50Hz/60Hz, up to 380V Installation mode Device type or guide rail type
rated supply voltage for liquid level automatic control at
places of civil water tower, high cistern, and underground
conservation pool etc. 4. Wiring diagram
Wiring diagram for JYB-714, JYB-714B, JYB-714C
220V water supply mode
N L
QS
1 8
2 7
G
KM 3 6
KM 4 5
L3 L2 L1
QS
1 8
2 7
KM 3 6
KM 4 5
M
3~
6 5 4 3
N L
2×φ4.4±0.2
QS
70max
1 8
2 7 7 8 1 2
KM 3 6 108max
KM 4 5
40±0.3
M 50max
L3 L2 L1
QS
1 8
2 7
KM 3 6
KM 4 5
M
3~
6 5 4 3
2×φ4.4±0.2
70max
7 8 1 2
108max
40±0.3
50max
6 5 4 3
2×φ4.4±0.2
70max
7 8 1 2
108max
40±0.3
50max
70×50×20(mm) 52×44×31(mm)
6 5 4 3 4.2
2 1 11 10
CZS08C
70max
9
35.4
52max
34
35.4
4
2-M4×30
4
CZF11A-E
7 8 1 2
5 6 7 8
34 31max
44max
40max 20max
50max
Applicable relay type: JSS48A, JDM1-48, KG10M, JYB-714 and NJS1 Applicable relay type: JS14S device type, and JDM1-14
CZS08G CZS08X-E (with finger safety protection)
G
48.8×40×20.1(mm) 72×43.6×21(mm)
32
40max 20.1max 6 5 4 3
4.2
2 1 B 7
6 5 4 3
72max
50max
35.4
48.8max
CZS08X-E
7 8 1 2
7 8 1
6 5 4 3
34max 21max
43.6max
Applicable relay type: JSS48A, NJS1, Applicable relay type: JSZ3A, JSZ3C, JSZ3-2/3,
JDM1-48, KG10M, and JSZ3H-Y JSZ3K, JSZ3R, JSZ3F, and JSZ3Y
CZY08B-01 (wide type, copper strip connection) CZY14B (copper strip connection)
63×30.5×26(mm) 63×30.5×26(mm)
8 5 8 7 6 5
4 1 4 3 2 1
63max
63max
35.4
35.4
4
4
1 1 1 1
4 3 4 3
1 1 1 1 9
2 9 2 1 0
25 26max 25 26max
30.5max 30.5max
φ32.4×36.2(mm) φ32.4×36.2(mm)
72×23×31(mm) 72×30×31(mm)
4 1 3 2 1
8 5 8 7 6 5
15 22
72max
72max
35.4
35.4
59
59
59
59
12 9
12 11 10 9
14 13
4 14 13
4 4
31max
15 31max 22
23max 30max
4. Coil specification
AC
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
6
12
24
36
48 (80%~110%)
≤80%Un ≥20%Un 1.2VA
110 Un
127
220
230
380
DC
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
5
6
12
24
(75%~110%)
36 ≤75%Un ≥10%Un 0.9W
Un
48
110
127
220
1 2 1 4 1 2 3 1 2 3 4
3 4 5 8 4 5 6 5 6 7 8
Standard type 5 6 9 12 7 8 9 9 10 11 12
13 14 10 11 13 14
7 8
1 1 2 4 1 4 1 2 3 1 2 3 4
5 3 4 8 5 8 4 5 6 5 6 7 8
5 6
9 12 9 12 7 8 9 9 10 11 12
with indicator
13 14 13 14 10 11 13 14
7 8
1 2 1 4 1 2 3 1 2 3 4
3 4 5 8 4 5 6 5 6 7 8
5 6
9 12 7 8 9 9 10 11 12
with indicator and diode
13 14 10 11 13 14
7 8
(+) (+) (+) (+)
10 13.2
13.2 13.2
4.4
3.8
4
4.6
4
G
6.4 4.1
6.4 4.1
6.4 4.1
6
18
16.9
16.9
16.9
8×φ1.8
8×Φ1.3 11×Φ1.3
14×Φ1.3
14.2
35.5max
35.5max
35.5max
35.5max
Plug-in type
7max
7max
7max
7max
5 2.6 2.6 2.6
35.5max
35.5max
35.5max
PCB type
5max
5max
5max
5max
1.5 1 1 1
1 2 1 4 1 2 3 1 2 3 4
3 4 5 8 4 5 6 5 6 7 8
43max
43max
43max
43max
38
38
38
38
5 6 9 12 7 8 9 9 10 11 12
Top flange type 13 14 10 11 13 14
7 8
35.5max
35.5max
35.5max
7max
7max
7max
NJDC-17
Small electromagnetic relay
with test button
1. General
2Z,2ZS, 3ZS, 4ZS contact forms; with self-locking test
button; transparent dust cover package, diverse
mounting modes available; equipped with a variety of
sockets options; optional with the specifications of
the status indicator.
3. Technical data
3.1 Contact parameters
Contact form 2Z(C),3Z(C),4Z(C)
Initial contact resistance 100mΩ
Contact Material Ag alloy
Contact load (COSΦ = 1.0) 2Z:10A;2ZS,3ZS:5A;4ZS:3A(220VAC/28VDC)
Maximum switching voltage 250VAC/125VDC
Maximum switching current 2Z:10A;2ZS,3ZS:5A;4ZS:3A
2Z:2200VA/280W
Maximum switching power 2ZS,3ZS:1100VA/140W
4ZS:660VA/84W
5
Electrical life (times) 1×10 (See safety certification report)
Mechanical life (times) 1×107
3.4 Specifications
Rated voltage VDC Action voltage VDC (≤) Release Voltage VDC (≥) Coil resistance Ω ± 10%
5 3.75 0.5 28
6 4.5 0.6 40
Rated voltage VAC Action voltage VAC (≤) Release Voltage VAC (≥) Coil resistance±10%
6 4.8 1.2 10.5
12 9.6 2.4 44
Bottom wiring diagram (2Z) Bottom wiring diagram (2ZS) Bottom wiring diagram (3ZS) Bottom wiring diagram (4ZS)
1 2 1 4 1 2 3 1 2 3 4
3 4 5 8 4 5 6 5 6 7 8
5 6 9 12 7 8 9 9 10 11 12
13 14 10 11 13 14
7 8
Bottom wiring diagram Bottom wiring diagram Bottom wiring diagram Bottom wiring diagram
G
(2Z with indicator) (2ZS with indicator) (3ZS with indicator) (4ZS with indicator)
1 1 2 4 1 4 1 2 3 1 2 3 4
5 3 4 8 5 8 4 5 6 5 6 7 8
5 6
9 12 9 12 7 8 9 9 10 11 12
13 14 13 14 10 11 13 14
7 8
Bottom wiring diagram (2Z Bottom wiring diagram (2ZS Bottom wiring diagram (3ZS Bottom wiring diagram (4ZS
with indicator and diode) with indicator and diode) with indicator and diode) with indicator and diode)
1 2 1 4 1 2 3 1 2 3 4
3 4 5 8 4 5 6 5 6 7 8
5 6
9 12 7 8 9 9 10 11 12
13 14 10 11 13 14
7 8
(+) (+) (+) (+)
10 13.2
13.2 13.2
4.4
3.8
4
4.6
4
4.1
4.1
4.1
6
18
6.4
6.4
16.9
16.9
6.4
16.9
8-φ1.8
8-Φ1.3 11-Φ1.3
14-Φ1.3
14.2
Outside dimensions drawing Outside dimensions drawing Outside dimensions drawing Outside dimensions drawing
(2Z pluggable) (2ZS pluggable) (3ZS pluggable) (4ZS pluggable)
35.5max
35.5max
35.5max
7max
7max
7max
7max
5 2.6 2.6 2.6
PCB outline drawing (2Z) PCB outline drawing (2ZS) PCB outline drawing (3ZS) PCB outline drawing (3ZS)
35.5max
35.5max
35.5max
5max
5max
5max
5max
1.5 1 1 1
6 Ordering Information
Relay Model D: with status indicator Contact form Coil rated voltage Terminal form
B: with status indicator 2Z: two sets of conversion(2C) DC (5 ~ 220) V 1: PCB type
And surge suppression (DC) 2ZS: two sets of conversion(2C) AC (6 ~ 380) V 6 or omitted: Plug-in
M: with arc suppression cover 3ZS: three sets of conversion(3C)
(Used for 4ZS specifications) 4ZS: four sets of conversion(4C)
No: ordinary type
3. Technical data
3.1 Contact data
21.5max 27.5max
1 2
3 4
35.5max
7.5max
5 6
7 8
5 5 0.5
1 2 21.5max 27.5max
3 4
35.5max
5 6
5max
7 8
1.5 0.5
Connection diagram (bottom view) 2Z(B) Outline drawing (lateral flange type)
43max
1 2 27.5max 21.5max
3 4
3.8
35.5max
5 6
7.5max
18.15
7 8
(+) 5 0.5 5
38
0.5 5 5
10
7.5max
3.8
35.5max
4.6
G
6
18
27.5max 21.5max
8×φ1.8
3.5
8
2
4
6
1
3
14.2
38
43max
4. Coil specification
AC
Rated voltage Holding voltage Must drop-out voltage Operating range Power consumption
6
12
24
36
48 ≤80%Un ≥20%Un (80%~110%)Un 1.2VA
110
127
220
230
380
DC
Rated voltage Holding voltage Must drop-out voltage Operating range Power consumption
5
6
12
24
G
36 ≤75%Un ≥10%Un (75%~110%)Un 0.9W
48
110
127
220
5. Characteristics
Insulation resistance(at 500VDC) MΩ 100
Dielectric Between coil & contacts 1500VAC
strength Between open contacts 500VAC
Operation time ms ≤25
Release time ms ≤25
Shock resistance m/s2 100
Vibration (10~55)Hz,1mm double amplitude
Humidity 90% RH at +20℃
Ambient temperature range ℃ -25~+55
Termination Plug-in, PCB
Dimension mm 27.5×21.5×35.5
1 4 1 2 3 1 2 3 4 1 4 1 2 3 1 2 3 4
5 8 4 5 6 5 6 7 8 5 8 4 5 6 5 6 7 8
9 12 7 8 9 9 10 11 12 9 12 7 8 9 9 10 11 12
13 14 10 11 13 14 13 14 10 11 13 14
1 4 1 2 3 1 2 3 4 13.2
13.2 13.2
4.4
5 8 4 5 6 5 6 7 8
4
4.1
4.1
4.1
9 12 7 8 9 9 10 11 12
6.4
6.4
16.9
16.9
6.4
16.9
13 14 10 11 13 14
(+) (+) (+)
8×Φ1.3 11×Φ1.3
14×Φ1.3
Dimensions
35.5max
35.5max
7max
7max
7max
0.5
35.5max
35.5max
35.5max
18.15
5max
5max
5max
2
35.5max 7max 0.5
1 1 1 38
Left view
1 4 1 2 3 1 2 3 4
5 8 4 5 6 5 6 7 8
35.5max
35.5max
35.5max
43max
43max
43max
38
38
38
9 12 7 8 9 9 10 11 12
13 14 10 11 13 14
7max
7max
7max
3.5 3.5 3.5
2.6 2.6 2.6
2C, front installation 3C, front installation 4C, front installation 2C, lateral flange 3C, lateral flange 4C, lateral flange
(top flange) (top flange) (top flange)
3. Technical data
3.1 Contact parameters
3.4 Specifications
Rated voltage VDC Action voltage VDC (≤) Release Voltage VDC (≥) Coil resistance Ω ± 10%
6 4.5 0.6 24
12 9.0 1.2 80
Rated voltage VAC Action voltage VAC (≤) Release Voltage VAC (≥) Coil resistance (20 ℃) Ω ± 10% G
6 4.8 1.2 7
12 9.6 2.4 19
24 19.2 4.8 80
Bottom wiring diagram (NJDC-12/2Z) Ou tside dime nsions drawi ng (NJDC-12/2Z) Ou tside dime nsions drawi ng (NJDC-12/3Z)
4 5 35max 35max
3 6
6 7 8 9
10
2 7
7
5
35max
11
35max
6
1 8
1
5
4
1
2 4 2
3 3
6
52.5max
52.5max
5 7
4 8
67max
67max
3 9
2 10
1 11
8.9±0.15
8.9±0.15
6. Ordering Information
6
12
24
36
48 80%Un 20%Un (80%~110%)Un 3VA
110
127
220
230
DC
380
G
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
5
6
12
24
36 75%Un 10%Un (75%~110%)Un 2W
48
110
127
220
35max 35max
4 5
6 7 8 9
3 6
10
7
5
35max
35max
8
11
6
2 7
5
4
1
2 4 2
1 8 3 3
JQX-10F/2Z
52.5max
52.5max
5 7
4 8
67max
67max
3 9
2 10
1 11
8.9±0.15
JQX-10F/3Z
8.9±0.15
JQX-10F/2Z JQX-10F/3Z
3. Technical data
Contact Arrangement 2C, 3C
Initial contact resistance mΩ 100
Contact material Silver alloy
Rated load (resistive) 10A/220VAC, 10A/28VDC
VAC 250
Max. switching voltage
VDC 125
Max. switching current A 10
VA 2200
Max. switching power
W 280
JTX Miniature power relay Electrical endurance Cycles(×103) 100
6
1. General Machenical endurance Cycles(×10 ) 10
1.1 10A switching current
1.2 Various sockets available 4. Coil specification
1.3 Wide range of coil ratings AC
1.4 Certificate: UL, CE
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
6
12
24
36
48 80%Un 20%Un (80%~110%)Un 3VA
110
127
220
230
380
G
DC
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
5
6
12
24
36 75%Un 10%Un (75%~110%)Un 2W
48
110
127
220
35max 35max
4 5 7
6 8 9
10
7
3 6
35max
35max
8
11
6
5
4
1
2 7
2 4 2
3 3
1 8
JTX-2C
52.5max
52.5max
6
5 7
4 8
67max
67max
3 9
2 10
1 11
JTX-3C
8.9±0.15
8.9±0.15
JTX-2C JTX-3C
VDC/VAC
Coil voltage: DC: 6V~220V;
AC: 6V~380V
Contact configuration: 2P=2C;
3P=3C
Series
3. Technical data
Contact Arrangement 2C, 3C
Initial contact resistance mΩ 100
Contact material Silver alloy
Rated load (resistive) 10A/220VAC, 10A/28VDC
VAC 250
Max. switching voltage
VDC 125
Max. switching current A 10
VA 2200
Max. switching power
JMK Miniature power relay Electrical endurance
W
Cycles(×103)
280
100
1. General
Machenical endurance Cycles(×106) 10
1.1 10A switching current
1.2 With indicator to be selected
1.3 Full range of AC and DC coil 4. Coil specification
1.4 Certificate: UL, CE AC
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
6
12
24
36
48 80%Un 20%Un (80%~110%)Un 3VA
110
127
220
230
G
380
DC
Rated Holding Must drop- Operating Power
voltage voltage out voltage range consumption
5
6
12
24
36 75%Un 10%Un (75%~110%)Un 2W
48
110
127
220
35max 35max
4 5
3 6 6 7 8 9
10
7
5
35max
35max
8
2 7
11
6
1 8
5
4
1
2 4 2
3 3
JMK2P-Ⅰ
52.5max
52.5max
6
5 7
67max
67max
4 8
3 9
2 10
1 11
JMK3P-Ⅰ
8.9±0.15
8.9±0.15
JMK2P-Ⅰ JMK3P-Ⅰ
35.5
18 36
86
1P,2P 3P,4P
NJMC1-32
70
35.5
18 36 54 72
86
1P 2P 3P 4P
52×41×21.5(mm) 52×41×21.5(mm)
2 1 8 7
2 1 8 7
CZF08A
52max
52max
33 33
35.4
35.4
2-M4×20 2-M4×20
2×φ4
2×φ4
CZF08A
CZF08A-E
3 4 5 6
3 4 5 6
33 21.5max 33 21.5max
41max 41max
Applicable relay type: JQX-10F/2Z, JTX-2C, JMK2P-I Applicable relay type: JQX-10F/2Z, JTX-2C, JMK2P-I
CZF11A CZF11A-E(With finger safety protection)
G
52×44×31(mm) 52×44×31(mm)
2 1 11 10 2 1 11 10
3 9
3 9
52max
52max
33
35.4
35.4
34
4
2-M4×20 2-M4×30
4 4
2×φ4
CZF11A CZF11A-E
5 6 7 8 5 6 7 8
33 31max 34 31max
41max 44max
Applicable relay type: JQX-10F/3Z, JTX-3C, JMK3P-I Applicable relay type: JQX-10F/3Z, JTX-3C, JMK3P-I
79×29×33(mm) 68×30×28(mm)
2 1
4 3
4 3
2 1
19
35.4
68max
68
79max
35.4
68
4
CZT08A-E
2-M4×12
6 5
8 7
8 7
6 5
72×23×31(mm) 72×30×31(mm)
4 1
3 2 1
8 5
6 5 4
15
22
72max
72max
35.4
59
59
35.4
59
59
CZY08A-E
2-M4×10 2-M4×10
CZY11A-E
12 9
9 8 7
14 13
11 10
4 4
15 31max 22 31max
30max
23max
72×30×31(mm) 63×30.5×26(mm)
3 2 1
8 5
8 7 6 5
4 1
22
72max
35.4
63max
59
59
35.4
4
CZY14A-E 2-M4×10
1 1
12 11 10 9 4 3
4 14 13 1
2 9
4
31max
22 25 26max
30max 30.5max
63×30.5×26(mm) 63×30.5×26(mm)
G
6 5 4 8 7 6 5
3 2 1 4 3 2 1
63max
63max
35.4
35.4
4
1 1 1 1
1 0 4 3
1 1 1 9
9 8 7 2 1 0
25 26max 25 26max
30.5max 30.5max
Applicable relay type: JZX-22F(B)/3Z, NJX-13FW(B)/3ZS, Applicable relay type: JZX-22F(B)/4Z, NJX-13FW(B)/4ZS,HH54P(L) ,
HH53P(L), MY3(N) JZX-18F(L)/4Z, MY4(N)
63×30.5×26(mm)
8 7 6 5
4 3 2 1
63max
35.4
4
1 1
4 3
1 1 1 9
2 1 0
25 26max
30.5max
NG102 NG103
Applicable relay type: CZY□A series、CZT□A series Applicable relay type: CZY□B series、CZT□B series