Simple Setting for MD Standard type Machines

On Version MH-4.02

1. How to enter different parameter levels ?

POWER ON ( Level 1 【001 - 046】 )

+ POWER ON ( Level 2 【047 - 122】 )

+ POWER ON ( Level 3 【123 - 251】 )

+ POWER ON ( Level 4 【 176 - 251】 )

+ POWER ON ( Level 5 【 208 - 251】 )

A + B + POWER ON ( Return to factory setting )


PAGE - 2

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
1 H Maximum sewing speed 50 - 9999 spm 4000 Maximum speed adjustments
The slow start operation mode is selected. This is valid when the panel [SL] key is ON in the normal mode.
T:Slow start operation will begin when the power is turned ON or when the first toe down after thread trimming,
2 SLM Slow start operation mode T/A T
P or the first external run signal (S0,S1) is turned ON.
O
W A:Slow start operation will begin when the pedal is toed down or when the external run signal (S0,S1) is turned ON.
E Setting the multiple to the value of 【042. CUD】
R 3 CNR Counter ratio selection 1 - 100 1
Connection :【042. CUD】,【159. O4】,【097. TK3】
..
4 N Start back-tacking speed 50 - 8000 spm 1800 Start back-tacking speed adjustments
O
5 V End back-tacking speed 50 - 8000 spm 1800 End back-tacking speed adjustments
N 6 B Bar-Tacking Speed 50 - 8000 spm 1800 Repeat bar-tacking speed adjustments
7 S Slow start speed 50 - 2000 spm 400 Slow start speed adjustments
8 SLS Stitch numbers for Slow start 0 - 99 stitches 2 Slow start stitches setting
9 A Automatic constant-stitch sewing speed 50 - 8000 spm 3000 Valid only at the auto pattern sewing or one shot signal(SH)active
Only at the last seam of pattern sewing
10 ACD Automatic sewing End back-tacking ON/OFF ON ON:Valid.
OFF:Invalid.
J = JUKI mode , B = BROTHER mode.
11 RVM Back-tacking mode selection J/B B J:Active when motor stop or running
B:Active only when motor running
Start back-tacking mode selection
A:One shot sewing
M:Pedal control and motor can stop at middle way.
SU:One shot sewing but motor stops at needle up by [027.CT] timer at end of each seam.
SD:One shot sewing but motor stops at needle down by [027.CT] timer at end of each seam.
A/M/SU/SD/A1/SU1/SD
12 SMS Mode selection for Start back-tacking A A1:One shot sewing , Add one seam by one stitch.
1/ AN/SUN/SDN
SU1:One shot sewing , Add one seam for one stitch, but motor stops at needle up by [027.CT] timer at end of each seam.
SD1:One shot sewing , Add one seam for one stitch, but motor stops at needle down by [027.CT] timer at end of each seam.
AN:One shot sewing , Add one seam by N stitches.
SUN:One shot sewing , Add one seam by N stitches, but motor stops at needle up by [027.CT] timer at end of each seam.
SDN:One shot sewing , Add one seam by N stitches, but motor stops at needle down by [027.CT] timer at end of each seam.
Mode selection at the end of Start back-tacking
CON:At the end of Start back-tacking ,machine continues sewing if pedal pressed or START signal on (standing operation)
13 TYS Mode selection at the end of Start back-tacking CON/STP/TRM CON
STP:At the end of Start Back-Tacking, machine stops and must re-start by pedal command.
TRM: Making the trimming cycle once the Start Back-Tacking finished. ( Mini Bar tacking )
Valid only when the operation panel disconnected.
14 SBT Start back-tacking function selection ON/OFF ON ON:Perform
OFF:Not perform
15 SBA Setting stitches A of Start back-tacking 3
0 - 15 stitches Start back-tacking stitches setting ,【014. SBT】= ON valid
16 SBB Setting stitches B of Start back-tacking 3
17 SBN Setting turns of Start Back-tacking 0 - 4 times 2 Setting the seam times of Start back-tacking ,【014. SBT】= ON valid
18 BT1 Stitch balance for Start Back-tacking 4 BT1=0:Invalid,1-8:Increase stitches of reverse seam,9-F:Increase stitches of forward seam
0-F
19 BT2 Stitch balance for Start Back-tacking 3 BT2=0:Invalid,1-8:Increase stitches of forward seam,9-F:Increase stitches of reverse seam
End back-tacking mode selection.
A:One shot sewing.
SU:One shot sewing but machine stops up position by 【027. CT】 timer at the end of each seam.
20 SME Mode selection for End back-tacking A/SU/SD/A1/SU1/SD1 A SD:One shot sewing but machine stops down position by 【027. CT】 timer at the end of each seam.
A1:One shot sewing , Add one seam by one stitch.
SU1:One shot sewing , Add one seam for one stitch, but motor stops at needle up by [027.CT] timer at end of each seam.
SD1:One shot sewing , Add one seam for one stitch, but motor stops at needle down by [027.CT] timer at end of each seam.
PAGE - 3

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Valid only when the operation panel disconnected.
21 EBT End back-tacking selection ON/OFF ON ON:Perform
OFF:Not perform
P 22 EBC Setting stitches C of End back-tacking 3
O 0 - 15 stitches End back-tacking stitches setting ,【021. EBT】 = ON valid
W 23 EBD Setting stitches D of End back-tacking 3
E 24 EBN Setting turns of End back-tacking 0 - 4 times 2 Setting the seam times of End back-tacking , 【021.EBT】 = ON valid
R
.. 25 BT3 Stitch balance for End Back-tacking 3 2 BT3=0:Invalid,1-8:Increase stitches of reverse seam,9-F:Increase stitches of forward seam
0-F
26 BT4 Stitch balance for End Back-tacking 4 1 BT4=0:Invalid,1-8:Increase stitches of forward seam,9-F:Increase stitches of reverse seam
O
Setting time interruption at each section end of 【012. SMS】,【020. SME】, 【031. SMB】= SU,SD setting valid.
27 CT 0 - 990 ms 50
N Back-Tacking. Conner stop timer, valid only at 【012. SMS】,【020. SME】,【031. SMB】setting SU/SD.
Additional 15 stitches are added to the Start and End back-tacking stitches function selection.( invalid with operation panel )
15 stitches plus on Start/End back-tacking
SB5 ON/OFF OFF ON:Valid. (MD Invalid.)
(with C60)
OFF:Invalid.
28 0. Depends on the pedal.
Mode selection for foot lifting . 1. At motor stop.
AFM 0/1/2/3 0
2. At trimming after .
3. At trimming after & at motor stop.
29 SB9 0-99 stitches plus on Start/End back-tacking 0 - 99 stitches 0 Additional setting stitches are added to the Start and End back-tacking stitches.( invalid with operation panel )
Added 1 stitch to the C segment of End back-tacking function selection.
Added 1 stitch to the C segment of End back-
30 BCC ON/OFF ON ON:Valid
tacking
OFF:Invalid
Bar-tacking mode selection.
A:One shot sewing.
31 SMB Mode selection for Bar-tacking A/M/SU/SD A M:Pedal control and motor can stop at middle way.
SU:One shot sewing but motor stops at needle up by 【027. CT】 timer at end of each seam.
SD:One shot sewing but motor stops at needle down by【027. CT】 timer at end of each seam.
Valid only when the operation panel disconnected.
32 BAR Bar-tacking selection ON/OFF OFF ON:Perform
OFF:Not perform.
33 BRC Setting stitches of Bar-tacking 0 - 99 stitches 4 One setting for all seams ,【032. BAR】 = ON valid.
34 BRN Setting turns of Bar-tacking 0 - 15 times 4 Setting the seam times of Bar-tacking ,【032. BAR】= ON valid.
35 BT5 Stitch balance for Bar-tacking 5 4 BT5=0 : Invalid,1-8 : Increase stitches of reverse seam; 9-F : Increase stitches of forward seam.
0-F
36 BT6 Stitch balance for Bar-tacking 6 3 BT6=0 : Invalid,1-8 : Increase stitches of forward seam; 9-F : Increase stitches of reverse seam.
Constant-stitch sewing mode selection.
37 SMP Mode selection for Constant-stitch sewing A/M M A:One shot sewing.
M:Pedal control and motor can stop at middle way.
Valid only when the operation panel disconnected.
38 PM Constant-stitch sewing selection ON/OFF OFF ON:Perform.
OFF:Not perform.
Setting stitches for section 1~4 of Constant-stitch
15 Stitches setting of seam P1-P4. 【038. PM】 =ON valid.
sewing
39 PS 0 - 250 stitches
Setting stitches for section 5~D of Constant-stitch
0 Stitches setting of seam P5-PD. 【038. PM】 = ON valid.
sewing
Wiper function selection.
40 WON Wiper function selection ON/OFF ON ON:Enable.
OFF:Disable.
Trimmer function selection.
41 TM Trimmer function selection ON/OFF ON ON:Enable.
OFF:Disable.
PAGE - 4

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Counter function mode selection. 
NOP : The counter is invalid.
U : Count up by stitches. When count over , counter will be auto- reset.
P D : Count down by stitches. When count over , counter will be auto- reset.
O
W US : Count up by stitches. When count over, motor stops and the counter must be reset by the A key on the front panel.
E Count mode selection DS : Count down by stitches. When count over, motor stops and the counter must be reset by the A key on the front panel.
NOP/U/D/US/DS/
R 42 CUD (For Bobbin Thread or Sewing NOP
UT/DT/UTS/DTS UT : Count up by trimming. When count over , counter will be auto- reset.
.. Piece)  
DT : Count down by trimming. When count over , counter will be auto- reset.
O
UTS : Count up by trimming. When count over,
N motor stops and the counter must be reset by the A key on the front panel.
DTS : Count down by trimming. When count over,
motor stops and the counter must be reset by the A key on the front panel.
43 UD Setting the count 1 - 9999 99 Count setting . (Note: The real number = the value of【003.CNR】X【043.UD】, when 【042.CUD】= U,D,US,UD valid only.)
44 PN Display the current count 0 - 9999 0 Display the current count of【043.UD】
45 SP Sewing speed 0 - 8000 0 Showing the current sewing speed.
Motor rotation direction adjustments. ( Viewed from the motor shaft side )
Connection : 【119, DD】
46 DIR Direction of motor rotation CW/CCW CCW
CCW :counterclockwise.
CW : clockwise.
PAGE - 5

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
47 MAC Machine Code 0 - 101 0 Machine code switchover
Positioning Mode selection Positioning Mode selection.
48 N12 (ON=UP ONLY, ON/OFF OFF ON:One position UP only.
+ OFF=UP/DOWN) OFF:Two positions Up / DOWN.
49 SPD Machine's pulley dimension. 1 - 250 mm 75 Setting machine pulley size when【051. PL】 = ON valid.
50 MPD Motor's pulley dimension. 1 - 250 mm 75 Setting motor pulley size when 【051. PL】 = ON valid.
Selecting the mode of setting pulley ratio.
P 51 PL Pulley's ratio setting mode selection ON/OFF OFF ON: Manually setting the pulley sizes by 【049, SPD】,【050, MPD】 .
O
W OFF:Automatically setting the pulley sizes by the CPU.
E Braking time of motor
R 52 BT Braking time of motor 50 - 500 ms 200
..
Slow start at the first cycle of power ON function selection.
O
53 POL Slow start at the first cycle of power ON ON/OFF ON ON:Enable and speed is set by 【007. S 】.
N OFF:Disable.
Motor stops with brake function.
54 BK Motor braked at normal stop ON/OFF OFF ON:Enable.
OFF:Disable.
Valid only when needle stops at up position.
ON:Enable.
When the needle stops at up position, the first stitching will be done with a reverse angle which is set by
55 SRM Motor start running with a reverse angle ON/OFF OFF the 【056.SRA】.
OFF:Disable.
Exception: If【147. INA】= BCR, an external switch may be used as a selection of ON / OFF to this function.
56 SRA Setting the angles of 【055. SRM】 1 - 360 degrees 60 Valid only when【055. SRM】= ON.

57 TRU Motor stops with a reverse angle after trimming ON/OFF OFF ON:Enable.
OFF:Disable.
58 TR8 Setting the angles of 【057. TRU】 1 - 360 degrees 40 Valid only when【057.TRU 】= ON .
59 M Middle speed L speed - 8000 spm 800 Setting the middle speed.
60 L Low speed 50 - 500 spm 250 Low speed adjustments
61 T Thread trimming speed 50 - 500 spm 215 Thread trimming speed adjustments
For machines have HP function only.
Mode for foot lifting stroke change at special
62 HPM ALT/MON MON 【 ALT 】mode : Presser foot lifting stroke changed by each time of the HP switch pushed on.
compound feed machine.
【 MON 】mode : Presser foot lifting stroke must be remained by the HP switch kept on.
M : Magnetic type.
63 FTP Type selection for foot lifting solenoid M/A M A : Air type.
Note : When set at A type, 【064. FO 】and【065. FC 】setting will be invalid. It will be full on.
64 FO Full-On time setting for foot lifting solenoid 0 - 990 ms 350 Only valid when【063. FTP】set at『 M 』mode. For solenoid pulling torque adjustment.
Only valid when【063. FTP】set at「M」mode. For solenoid's switching power adjustment.
65 FC Duty cycle time setting for foot lifting solenoid 10 - 90% 35 Note : Wrongly adjustment will cause the solenoid unable
to lift or over-heating.
66 FD Running-Delay time setting 0 - 990 ms 0 If foot lifter is installed, set 100 ms min. to ensure the presser foot will come down first.
Selection of solenoid protection.
67 FPM Protection for foot lifter solenoid. ON/OFF ON ON: The foot lifting solenoid activated time will be controlled by 【068. FP】.
OFF : The foot lifting solenoid will be always active unless heeling back the pedal.
Setting the lifting solenoid activated time.
68 FP Working time limit for foot lifter solenoid. (0 - 9990) x 0.01s 3000
Valid only when the【067. FPM】 = ON.
Use this setting as foot lifter delay time at half heeling the pedal. If foot lifter is installed, set 100 ms min.
1.If timing set to short, it will cause foot lifter started once before trimming at full heeling the
69 HD Sensitivity adjustment for half-heeling pedal 0 - 990 100
pedal. 2.If timing set to long, it will cause foot lifter started too slow
or laggard at half heeling the pedal.
ON : No foot lifting at half-heeling. (but full-heeling can operate foot lifter )
70 HHC Cancel foot lifting at half-heeling pedal ON/OFF OFF OFF : Operate foot lifting at half-heeling.
Note : When【134.KLK】= ON for interlock-stitch machine, this function can be controlled by A key on the control box panel.
PAGE - 6

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
ON : No foot lifting at heeling pedal.
71 FL Cancel foot lifting at full- heeling pedal ON/OFF OFF
OFF : Has foot lifting at heeling pedal.
PAGE - 7

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
ON : No function at heeling pedal. ( foot lifter and need up function are also invalid)
72 FHC Cancel trimming at full-heeling pedal ON/OFF OFF
OFF : Trimmer is functioned at heeling pedal.
When the pedal is returned to neutral position, trimming works automatically.
+ 73 NTC Trimming works at neutral pedal ON/OFF OFF O N : Enable. Only valid when【072.FHC】= OFF
OFF:Disable.
Foot lifter output signal converted.
P 74 FRV Converter for foot lifter signal output ON/OFF OFF ON : The foot lifter goes up during sewing.
O
W OFF: Function invalid.
E Trimming device protection for Cover-Stitch machine.
R Safety switch protection mode
.. 75 SFM NC/NO NO NC:Normal close. When signal at open , motor immediately stops and rotation symbol will stop.
NO:Normal open. When signal at close , motor immediately stops and rotation symbol will stop.
O
With TCL trigger signal input, the next trimming will be cancelled as full heeling the pedal.
N 76 TCL Thread trimmer cancel ON/OFF OFF ON:Valid.
OFF:Invalid.
Canceling the interlock timer for quick restarting. For machine without trimmer device only.
P 77 ILC Cancel of interlock timing after full heeling pedal ON/OFF OFF ON:Valid.
O
W OFF:Invalid.
E Motor running mode at trimming sequence selection.
R
.. LK:For general Lock-Stitch machines .Trimming from needle down to up.
RK:For Chain-Stitch machine easy pull out cycle. Needle stops with a reverse angle set by 【116.DRU】.
O
78 TRM Motor running mode at trimming sequence LK/RK/KA/KB/KC/KD LK KA:For general Cover-Stitch machines with under trimmer only.
N KB:For special Cover-Stitch machines with upper trimmer .
KC:Valid only when 【079. LTM】=TK and 【081. TS】>0, otherwise function same as LK mode.
KD:For general Cover-Stitch machines with under trimmer only , can change needle position.
Reference the timing chart of HVP-70.
T1:At down position delayed 【081. TS】 angles on, at up position delayed 【083. T2】 time off.
T2:At down position delayed【081. TS】 angles on, extended【084. TE】 angles off.
T3:At down position delayed 【081. TS】 angles on, extended 【083. T2】time off.
Mode selection for trimming sequence.
79 LTM T1/T2/T3/T4/TK/TS/T7 TS T4:At down position delayed 【082. T1】 time on, extended【083. T2】 time off.
( For TM output signal )
TK:At up position delayed【082. T1】 time on, extended【083. T2】 time off.
TS:At down position always on, at up position delayed【082. T1】 time on, extended【083. T2】 time.
T7:At down position delayed【081. TS】angles on, at up position off, and delayed 【082. T1】time on,
extended【083. T2】time off.
Reference the timing chart of HVP-70.
L1:At down position delayed【085. LS】 angles on, at up position delayed 【087. L2】time off.
L2:At down position delayed【085. LS】angles on, extended【088. LE】angles off.
L3:At down position delayed 【085. LS】 angles on, extended 【087. L2】time off.
Mode selection for tension-release sequence.
80 LLM L1/L2/L3/L4/LK/LS/L7 LS L4:At down position delayed 【086. L1】 time on, extended 【087. L2】 time off.
( For ML output signal )
LK:At up position delayed【086. L1】 time on, extended【087. L2】 time off.
LS:At down position always on, at up position delayed【086. L1】 time on, extended 【087. L2】 time off.
L7:At down position delayed 【085. LS】 angles on, at up position off, and delayed 【086. L1】 time on,
extended【087. L2】 time off.
81 TS Delayed angles prior to trimmer engaged 0 - 360 degrees 0 Valid for【079. LTM】= T1/T2/T3/T7 .
82 T1 Delayed timing prior to trimmer engaged 0 - 990 ms 0 Valid for【079. LTM】= T4/TK/TS/T7.
83 T2 Trimming time 0 - 990 ms 0 Valid for【079. LTM】= T1/T3/T4/TK/TS/T7.
84 TE Setting angles of trimming 0 - 360 degrees 0 Valid for【079. LTM】 = T2 .
85 LS Delayed angles prior to tension release engaged 0 - 360 degrees 0 Valid for 【080. LLM】 = L1/L2/L3/L7 .
86 L1 Delayed timing prior to tension release engaged 0 - 990 ms 0 Valid for【080. LLM】= L4/LK/LS/L7.
87 L2 Timing of tension release 0 - 1500 ms 0 Valid for【080. LLM】 = L1/L3/L4/LK/LS/L7.
88 LE Setting angles of tension release 0 - 360 degrees 0 Valid for【080. LLM】= L2 .
PAGE - 8

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description

Delayed timing prior to upper trimmer engaged


89 D1 0 - 990 ms 30 Only valid when【078. TRM】set at『 KB 』mode.
at down-stop
Signal output from the wiper MW.
90 D2 Setting timing of upper trimming at down-stop 0 - 2500 ms 90 See the KB timing chart.

91 D3 Timing recall of upper trimming at down-stop 0 - 990 ms 120
92 W1 Delayed timing prior to wiper engaged 0 - 980 ms 10 Time setting between needle up to wiper active.
P 93 W2 Setting timing of wiping 0 - 9990 ms 70 Wiper ON timer setting.
O
W 94 WF Delayed timing prior to foot lifter engaged 0 - 990 ms 50 Timer setting between wiper OFF to presses foot ON.
E Condense-Stitch function by【027. CT 】timer for needle up & motor stop.
R
.. ON:Enable. Note :【021. EBT 】=ON,【022. EBC】=8,【023.EBD】=3 and 【024.EBN】=2 and 【027. CT】=100
95 CSF Condense-Stitch function ON/OFF OFF must be adjusted.
O
OFF:Disable.
N WN3 WEDA cutter delay stitch count 10 WEDA cutter delay stitch count setting.
96 0 - 99 stitches
CON Setting stitches of Condense-Stitch sewing 8 Valid only when the [095. CSF] = ON.
Tape cutter on timer 0 - 2500 ms Tape cutter on timer setting x10 = 100 ms.
TK3 10
Bobbin counter alarm preaction value. 0 - 250 stitches When 【042.CUD】= US,DS the value is bobbin counter alarm preaction value.
97
Setting stitches prior to stop beyong Condense-
FOS 0 - 250 stitches 0 Valid only when the [095. CSF] = ON.
Stitch
ON : Normal stitch length.
98 SLU Stitch length selection for backtack ON/OFF OFF
OFF: Long stitch length.
Edge sensor function selection..
99 SEN Edge sensor function selection ON/OFF OFF ON:Enable.
OFF:Disable.
100 SRS Edge sensor signal check 1 0 - 99 stitches 1 Only valid when【099. SEN】set at ON. To avoid photo interference.
101 CMS Edge sensor signal check 2 0 - 99 stitches 3 Only valid when【099. SEN】set at ON. To avoid photo interference.
102 SE Setting stitches from edge sensing to stop 1 - 999 stitches 6 Setting Stitches to stop., when edge signal detected. Only valid when【099. SEN】set at ON
When edge signal detected out. Motor will do the trimming cycle automatically.
103 SET Trimming mode at sensory stop ON/OFF OFF ON : After the stitches of【102. SE】finished, trimming works.
OFF : After the stitches of【102. SE】finished, trimming doesn't work.
When【PSU】signal detected, running the stitches then stop at UP position.
104 PSU Stitches for emergency up-stop 1 - 99 stitches 6 The speed of setting stitches is set by 【009. A 】.
When【PSD】signal detected, running the stitches then stop at DOWN position.
105 PSD Stitches for emergency down-stop 1 - 99 stitches 6 The speed of setting stitches is set by 【009. A 】.

When the pedal on and the edge signal detected, the motor can start running.
106 PSN Re-start function at emergency stop ON/OFF ON ON:Enable.
OFF:Disable.
When motor running, manually push the Touch Back switch , reverse solenoid engaged on at needle up.
Manual Back-Tacking engaged at
107 S7U ON/OFF OFF ON:Valid.
needle-up position
OFF:Invalid.
When motor running, manually push the Touch Back switch , reverse solenoid engaged on at needle down.
Manual Back-Tacking engaged at
108 S7D ON/OFF ON ON:Valid.
needle-down position
OFF:Invalid.
During sewing, reverse output will be OFF at needle UP or DOWN position .
Mode for de-engaging Back-Tacking
109 ROF ON/OFF OFF ON:At『 needle UP 』position.
OFF:At『 needle DOWN 』position.
The trimming and reverse solenoid activated on the same time.
110 TB Mode for Back-Tacking at trimming cycle ON/OFF OFF ON:Valid.
OFF:Invalid.
Correction mode selection for Touch-Back Switch. Note :【010. ACD】= OFF and【011. RVM】= B
111 COR Correction Mode of Touch-Back Switch 1/2 2 1: Doing correction with one touch the Touch-Back switch .
2: Doing correction with double touch the Touch-Back switch.
PAGE - 9

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
W : Regular wiper function (active 1 time when full heeling back after sewing)
O : Wiper works at each full heeling back (unlimited )
112 WMD Wiper function related to full-heeling pedal W/O/A W
A : Wiper works only the pedal is kept full heeling back . Wiper turn off when the pedal return to neutral.

Note : Wiper on time controlled by the 【093. W2】.
113 DEG Needle DOWN position stop angle 5 - 180 degrees 12 Adjust the needle down stop position.
P 114 UEG Needle UP position stop angle 5 - 180 degrees 12 Adjust the needle up stop position.
O
W Power on display condition selection.
E 115 PMD Power on display condition ON/OFF OFF ON:When power switch turned on, the panel displays previous condition. (Keep previous condition).
R
.. OFF:When power switch turned on, the panel displays normal mode.
Valid only when【078. TRM】=『RK』mode
O 116 DRU Reverse angles through Needle down and up 1 - 360 degrees 180
Motor reverses from needle down, and stops at the needle upper dead point.
N 117 ER Error code display 10 SETS - Error code history display , total 10 events can be memorized.
ON:Without the synchronizer , motor is running as a clutch motor and stops at random position.
118 NOS Converting to a clutch motor selection ON/OFF     OFF
OFF:With synchronizer .

119 DD Direct drive or belt drive ON/OFF OFF ON:Direct drive.


OFF:Belt drive.
F U : Regular operation -- full heeling for trimming and foot lifting.
N U : Full heeling for up needle.
Mode selection for full-heeling after power on N O : No foot lifting function.
120 FHM FU/NU/NO/NUF/EFF FU
or trimming NUF : Full heeling for foot lifting and up
needle.
EFF : Full heeling for foot lifting and running at low speed.
O N : Automatic needle UP at power on.
121 ANU Needle goes up as power turned ON ON/OFF OFF
OFF : Function invalid.
122 HL Upper limit of maximum speed 50 - 9999 spm 4500 The motor's maximum speed setting.
PAGE - 10

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
123 FASET Factory default reset Factory setting reset
Program mode selection.
NOP:No function
NOP/LOAD/SAVE/ LOAD:Down load the program from C300 , C60 , F10 , C200 operation panel .
+ Program down load from /save to operation box
124 PG NOP SAVE:Save the program to C300 ,C60 , F10 , C200 operation panel.
(C300 , C60 , F10 , C200) / computer
COPY/IU/IV COPY:No function.
IU:Current sensor initial value.
P IV:Current sensor initial value.
O
W Function for the needle up switch.
E (Connection :【145. IN2】=U or C300 , C60 , F10 , C200 operation panel needle up switch)
R
.. A:Stitch changeover + inching
B:Stitch changeover only
O
C:Up needle only .
N 125 USM Function for the needle up switch A/B/C/D/E/F/G/H/I A D:Up needle and presser foot .
E:Inching one stitch only.
F:Inching one stitch backward only.
G:Backward running for【133. CHS】setting stitches.
H:Up needle + Tension on + Sewing suppression + O5 BTL Lamp blinks .
I :Up needle + Tension on + presser foot + Sewing suppression + O5 BTL Lamp blinks .
ON:Always enable.
126 USA Mode selection for【125. USM 】 ON/OFF OFF
OFF:Enable only at intermediate stop .
127 MAV Maximum voltage hold Maximum voltage display only.
128 MIV Minimum voltage hold Minimum voltage display only.
129 PV Current voltage display Display the current voltage.
130 OVD Over voltage setting 310 - 315 315V Over voltage setting
131 LVD Low voltage setting 0 - 160 70V Low voltage setting
Save the user's parameter setting into memory blocks for later use. Setting procedure:
1.Press [S] key + POWER ON LCD display 【123. FASET】
2.Press [P] key 9 times LCD
display 【132. UPG 】 3.Press [S] key
132 UPG User program saving 0-3 0 LCD display 【UPG. 0 】
4.Press [D] key to select a block number from【UPG. 0】 ~ 【UPG. 3 】.
5.Press [A] key to save the program.
Note : To recall the program, go to the memory block in 【UPG. 0】 ~ 【UPG. 3 】, use [C] key to call it back

and then
Valid onlypress [S] keyMAC】
when【047. to confirm
=『 and save.
10 』( For W582 angle stitch ) and【 011. RVM】= 『 B 』.
When half heeling the pedal, the needle goes up , pressing down
Function and stitches setting for Angle-Stitch the pedal, this function works. The『CHS』speed is set by【004. N 】.
133 CHS 1 - 99 stitches 5
device ( Pegasus W582)
Full heeling back : Same as interlock stitch machine function output.
ON: The A.B.C.D keys will be locked and defined to specific functions as follow :
A key : Cancel foot lifting after at half- heeling pedal .
B key : Cancel trimmer function at full heeling
134 KLK SBT/EBT Key Lock selection ON/OFF OFF pedal. C key : Cancel
wiper function at full heeling pedal.
D key : Start constant stitch setting
OFF:Unlocked.
135 TOT Auto-running full time setting 1 - 168 Hrs 1 Auto-running full time setting. when【138. UTD】 = ON valid.
(1-250 )x0.1S Auto-running on cycle time setting. when【138. UTD】 = ON valid.
136 TM1 Auto-running on cycle time setting 20
1-250 ms when [160.O5] is setting TF the value is output delay time (x10ms)
(1-250 )x0.1S Auto-running off cycle time setting. when【138. UTD】 = ON valid.
137 TM2 Auto-running off cycle time setting 20
1-250 ms when [160.O5] is setting TF the value is output delay time (x10ms)
ON:Enable.
138 UTD Auto-running test selection ON/OFF OFF
OFF:Disable.
139 PSL Speed curve adjustments 1 - 100% 85 The larger the value the faster to up speed
PAGE - 11

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Setting the parameter 【102. SE 】from C-300 operation box .
140 OSE Outside setting the 【102. SE 】 parameter ON/OFF OFF ON:Enable.
OFF:Disable.
+ Added 1 stitch to the second C segment of double Valid only when the double End Back-Tacking is performed.
141 BC3 End Back-Tacking ON/OFF OFF ON:Enable provided the parameter【030. BCC 】= ON .
OFF:Disable.
P Motor Shake function .
O
W 142 EFK Motror Shake function ON/OFF OFF ON:Enable.
E OFF:Disable.
R
.. Automatic standing operation can be done.
143 AT Automatic standing operation ON/OFF OFF ON:Enable.
O
OFF:Disable.
N Define the input function of IN1.
IO1:Control OT1 output of 【157.O1】
IN1=IO1/NOP/S4/CRL/IO2/RST NOP:No function.
input sw switchover IO1/NOP/S4/CRL/
144 IN1 IO1 S4: Motor is running with 【001. H 】 speed setting.
(MH without IO2/RST
hardware input) CRL:Should be set when 【225. CER 】 = ON .
IO2:Should be set when 【243. S10 】 = ON .
RST:Reset step counter , should be set when 【047. MAC 】 = 15,16,17 .
Define the input function of IN2.
USR:Up the needle by the angle of 【058. TR8 】when this switch pushed on.
U:Needle up function of 【125. USM 】.
NOP:No function.
IN2=USR/U/NOP/BTL/BTC/ST1/ZVR/ST2/ST3/S6 USR/U/NOP/BTL/BTC/ BTL:Back-tacking suppression / recall switch for SBT/ EBT only.
145 IN2 input U BTC:Back-tacking suppression + O5 BTL Lamp On / cancel for SBT/ EBT only..
sw switchover ST1/ZVR/ST2/ST3/S6 ST1:Inching one stitch only.
ZVR:An input signal for reverse sewing .
ST2:Up needle + Tension on + Sewing suppression + BTL Lamp blinks .
ST3:Up needle + Tension on + presser foot + Sewing suppression + BTL Lamp blinks .
S6:Safety switch .
IN3=WL/HT  Define the Pedal half toe function of IN3.
Pedal half toe control.
146 IN3 WL/HT HT WL:Disable.
(MH without hardware input)
HT:Enablel.
Define the input function of INA.
INA=BCR/PSU/NOP/SPL  BCR:An input signal for selecting ON / OFF of motor start with a reverse angle.
input sw switchover Valid only when 【125. USM 】=OFF.
147 INA BCR/PSU/NOP/SPL PSU
(MH without PSU:An input signal for emergency stop at up position.
hardware input) NOP:No function.
SPL:An input signal for speed limited by low speed of【060. L 】.
Define the input function of INC.
IO1:Must be selected when【196. BF 】. = ON .
INC=IO1/IO2/S0/SH/NOP/IO3  IO2:Must be selected when【194. A16 】=ON .
input sw switchover SH/IO1/IO2/S0/NOP/IO
148 INC NOP S0:An input signal for speed change limited by low speed of【060. L 】.
(MH without 3
hardware input) SH:A one-shot signal for speed change limited by 【009. A 】.
NOP:No function.
IO3:Should be set when 【243. S10 】 = ON .
PAGE - 12

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description

IND=TL/ES/NOP  Define the input function of IND.


input sw switchover TL:An input signal for trimmer output cancel .
149 IND TL/ES/NOP ES
(MH without ES:An input signal for emergency stop .
+ hardware input) NOP:No function.
Define the input function of INE.
S7:An input signal for reverse sewing .
P IO1: ME Not function.
O
W IO2:An input signal for reverse one stitch when motor stop and reverse sewing .
E NOTE:The【010. ACD】=off and【011. RVM】=B must be set.
R
.. INE=S7/IO1/IO2/CW/IO3/ST1/ST2/ST3/S2/PSD CW:Reverse run signal.
S7/IO1/IO2/CW/IO3/
150 INE input sw S7 IO3:An input signal for Inching one stitch only when motor stop and reverse sewing .
O ST1/ST2/ST3/S2/PSD
switchover NOTE:The【010. ACD】=off and【011. RVM】=B must be set.
N ST1:Inching one stitch only.
ST2:Up needle + Tension on + Sewing suppression + BTL Lamp blinks .
ST3:Up needle + Tension on + presser foot + Sewing suppression + BTL Lamp blinks .
S2:Trimming signal .
PSD:Emergency stop for down position.
Define the input function of INF.
INF=HP/F 
151 INF HP/F F HP:An input signal for high lift of walking foot.
input sw switchover
F:An input signal for knee switch.
INI=CRS/FAW/CLK  Define the input function of INI.
input sw switchover CRS:An input signal for counter reset .Note : Valid only when 【042. CUD】=U,D,US,DS,UT,DT,UTS,DTS .
152 INI FAW/CRS/CLK CRS
(MH FAW:A signal for bobbin thread detector.
without hardware input) CLK:the machine maintenance early warning function .
Define the input function of INK.
HP:An input signal for high lift of walking foot.
INK=HP/F/CRR/S1/IO1 F:An input signal for knee switch.
153 INK input sw switchover F/HP/CRR/S1/IO1 S1
CRR:ME Not function .
S1:Motor start running signal.
IO1:Tape cutter input signal.
Define the output function of OA.
OA=TM/KS1 
154 OA TM/KS1 TM TM:Trimmer output.
output switchover
KS1:Tape cutter output.
Define the output function of OB.
WP:Wiper output.
ML:Tension release output.
FK:Thread nipper output.
KS1:Tape cutter output.
NCL:Needle cooling output.
OB=WP/ML/FK/KS1/NCL/PUL/BUZ/ALM/BTL/HPL/M WP/ML/FK/KS1/NCL/ PUL:Puller output.
155 OB R output PUL/BUZ/ALM/BTL/HP WP BUZ:Buzzer output is turned On when the 【042. CUD】=US,DS,UTS,DTS and the count becomes end.
switchover L /MR RESET : When the counter reset by pushing the "A" key at panel of controller or by 【152.
INI】=CRS input signal.
ALM:Buzzer output is turned On when the 【152. INI】=CLK , and 【211. RH】seting value < 【199. PRH】seting value.
RESET : When the counter reset by pushing the "A" key at panel of 【RH.
xxxx】or by 【INI】 input signal.
BTL:BTL_LED output.
HPL:HP_LED output.
MR:reverse output.
PAGE - 13

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Define the output function of OD.
ML:Tension release output.
KS1:Tape cutter output.
+ KS2:No function.
KS3:No function.
KS4:Must be selected when 【204. BL】.
P OD=ML/KS1/KS2/KS3/KS4/NCL/BUZ/ALM/BTL/HPL/ ML/KS1/KS2/KS3/ NCL:Needle cooling output.
O MR/WP BUZ:Buzzer output is turned On when the 【042. CUD】=US,DS,UTS,DTS and the count becomes end.
W 156 OD ML
output switchover KS4/NCL/BUZ/ALM/ RESET : When the counter reset by pushing the "A" key at panel of controller or by 【152.
E BTL/HPL/MR/WP
R INI】=CRS input signal.
ALM:Buzzer output is turned On when the 【152. INI】=CLK , and 【211. RH】seting value < 【199. PRH】seting value.
.. RESET : When the counter reset by pushing the "A" key at panel of 【RH.
O
xxxx】or by 【INI】 input signal.
BTL:BTL_LED output.
N HPL:HP_LED output.
MR:reverse output.
WP:Wiper output.
Define the output function of O1.
OT1: Output by flip-flop control ,according to each input specifications while inputs IO1 are ON.
KS1:Tape cutter output.
PUL:Puller output.
CSL:Must be selected when 【225. CER】 = ON .
CK :Needle down pulse width output .
OT1/KS1/PUL/CSL/ KS2 :Should be set when 【243. S10 】 = ON or【205. BAF 】=1, 2.
O1=OT1/KS1/PUL/CSL/CK/KS2/STK/UC/
STK :Output by stitch length solenoid.
CK/KS2/STK/UC/ UC:Output is turned ON if at needle up position when the sewing machine is stopped.
PO1/PO2/P12/BUZ/ALM/BTL/HPL
157 O1 OT1
 output switchover PO1 :Needle down pulse width output .
PO1/PO2/P12/
(MH PO2 :Needle up pulse width output .
without hardware output)
BUZ/ALM/BTL/HPL P12 :Needle down , needle up pulse width output .
BUZ:Buzzer output is turned On when the 【042. CUD】=US,DS,UTS,DTS and the count becomes end.
RESET : When the counter reset by pushing the "A" key at panel of controller or by 【152.
INI】=CRS input signal.
ALM:Buzzer output is turned On when the 【152. INI】=CLK , and 【211. RH】seting value < 【199. PRH】seting value.
RESET : When the counter reset by pushing the "A" key at panel of 【RH.
xxxx】or by 【INI】 input signal.
BTL:BTL_LED output.
HPL:HP_LED output.
Define the output function of O3.
HP:Output for high lift for walking foot.
O3=HP/KS1/KS2/CK/KS3/CSR/KS4  KS1:Must be selected when【205. BAF】 = 1, 2.
HP/KS1/KS2/CK/KS3/ KS2:Must be selected when【196. BF】= ON .
158 O3 output switchover HP
(MH without hardware CSR/KS4 CK :Needle down pulse width output .
output) KS3 :Should be set when 【197. WDA 】or【243. S10 】 = ON .
CSR:Must be selected when 【225. CER】 = ON .
KS4:Trimmjng output function .
Define the output function of O4.
OT4:Reserve output.
BUZ:Buzzer output is turned On when the 【042. CUD】=US,DS,UTS,DTS and the count becomes end.
O4=OT4/BUZ/PO1/PO2/P12/ALM RESET : When the counter reset by pushing the "A" key at panel of controller or by 【152.
output switchover OT4/BUZ/PO1/PO2/P1 INI】=CRS input signal.
159 O4 OT4 PO1 :Needle down pulse width output .
(MH 2/ ALM
without hardware output) PO2 :Needle up pulse width output .
P12 :Needle down , needle up pulse width output .
ALM:Buzzer output is turned On when the 【152. INI】=CLK , and 【211. RH】seting value < 【199. PRH】seting value.
RESET : When the counter reset by pushing the "A" key at panel of 【RH.
xxxx】or by 【INI】 input signal.
PAGE - 14

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Define the output function of O5.
OT5:Reserve output.
HPL:HP_LED output.
+ PO1 :Needle down pulse width output .
PO2 :Needle up pulse width output .
O5=OT5/HPL/PO1/PO2/KS1/TF/P12/BTL/BUZ/ALM OT5/HPL/PO1/PO2/ KS1 :Should be set when 【243. S10 】 = ON .
P output
160 O5 OT5 TF :Trimming function output .
O switchover KS1/TF/P12/BTL/BUZ/
W (MH without hardware output) ALM P12 :Needle down , needle up pulse width output .
E BTL:BTL_LED output.
R BUZ:Buzzer output is turned On when the 【042. CUD】=US,DS,UTS,DTS and the count becomes end.
.. RESET : When the counter reset by pushing the "A" key at panel of controller or by 【152.
O INI】=CRS input signal.
ALM:Buzzer output is turned On when the 【152. INI】=CLK , and 【211. RH】seting value < 【199. PRH】seting value.
RESET : When the counter reset by pushing the "A" key at panel of 【RH.
N
xxxx】or by 【INI】 input signal.
Define the output function of O6.
STL:STK_LED output.
O6=STL/OT6/PO1/PO2/KS1/TB/P12 OT6:Output is turned ON for chain stitch bottom/lamp, when the pedal full heeling back or sewing machine running.
output switchover OT6/STL/PO1/PO2/ PO1 :Needle down pulse width output .
161 O6 STL
(MH without KS1/TB/P12 PO2 :Needle up pulse width output .
hardware output) KS1 :Should be set when 【243. S10 】 = ON .
TB :Trimming function output .
P12 :Needle down , needle up pulse width output .
O7=BTL/UC Define the output function of O7.
output switchover
162 O7 BTL/UC BTL BTL:BTL_LED output.
(MH without
hardware output) UC:Output is turned ON if at needle up position when the sewing machine is stopped.
163 BD SRM return operation stable timer 70 - 990 70 Stable timer for motor return operation.
164 MXI Maximum current limiter 5 - 22A 10A Maximum current limiter setting. Note : To avoid damage, adjustment should be done by engineer only.
165 WKT Weak braking torque scale 1-5 2 Weak braking torque scale setting.
The time for accelerating machine to high speed from the pedal toed down or when the external run signal
166 ACT Acceleration time 60 - 990 ms 140
(S1) is turned ON.
The time for the decelerating machine to stop from the pedal returned to neutral or when the external run signal
167 DCT Deceleration time 60 - 990 ms 160
(S1) is turned OFF .
168 HKP Motor's holding torque gain adj. 5 - 400 40 To reduce noise, the motor holding torque can be lowered down.
169 LKP Low speed gain 5 - 400 50 Low speed gain LKP adjustment.
170 KP Gain kp 5 - 150 40 Gain KP adjustment
171 KI Gain ki 100 - 3000 1800 Gain KI adjustment
172 KS Gain ks 1 - 40 18 Gain KS adjustment
173 QSK Quick stop counter 30 - 999 100 Note : Don't adjust.
174 QSP Quick stop speed 50 - 500 100 Note : Don't adjust.
Heavy duty function setting
175 HV Heavy duty ON/OFF OFF ON:Enable.
OFF:Disable.
PAGE - 15

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Positioning mode selection.
OFF: Needle up and down is adjusted by external synchronizer, and needle bar upper dead point is adjusted by【183.PUB】
A: Needle up is adjusted by 【179.PUA】, and needle down is adjusted by【181.PDA】.
+ B: Needle up is adjusted by 【179.PUA】, needle down is adjusted by【181.PDA】
176 VDN Positioning by index (reference) point OFF/A/B/C OFF and needle bar upper dead point is adjusted by 【183.PUB】.
C: When pedal control, needle up is adjusted by【179.PUA】, needle down is adjusted by【184.PDB】,【185.PDC】 ;
if U switch operation in half stitch control; then, can stop the motor at【179.PUA】,
【181.PDA】【184.PDB】,【185.PDC】. this function for handle stitch machine only.
P
O
W Defined one signal for two positioning function. Note : Valid only when 【176.VDN】=off .
E 177 SIN Single positioning signal synchronizer ON/OFF OFF ON:Enable. A single positioning signal synchronizer is used.
R
.. OFF:Disable. A regular synchronizer is used.
Valid only when【177. SIN】=ON +【176. VDN】= OFF.
O
178 NU Define the UP positioning signal mode H/L H/L L H: Input logic H active for needle up, and input logic L active for needle down.
N L: Input logic H active for needle down, and input logic L active for needle up.
179 PUA Virtual up A position edge angle 0 - 359 degrees 0 【176. VDN】=MODE "A","B","C" valid (from index point).
180 PUW Virtual up A position ON angle 10 - 70 degrees 40 【176. VDN】=MODE "A","B","C" valid (pulse width).
181 PDA Virtual down A position edge angle 0 - 359 degrees 180 【176. VDN】=MODE "A","B","C" valid (from index point).
182 PDW Virtual down A position ON angle 10 - 70 degrees 40 【176. VDN】=MODE "A","B","C" valid (pulse width).
183 PUB Virtual up B position edge angle 0 - 359 degrees 0 【176. VDN】=MODE "B" , "Off" valid (needle upper dead point).
184 PDB Virtual down B position edge angle 0 - 359 degrees 90 【176. VDN】=MODE "C" valid only
185 PDC Virtual down C position edge angle 0 - 359 degrees 270 【176. VDN】=MODE "C" valid only
186 MS Walking foot lifting maximum speed 200 - 5000 spm 3500 Walking foot maximum speed limiter
187 WS Walking foot lifting minimum speed 200 - 4800 spm 2000 The speed of HP solenoid on
Minimum stroke value of potentiometer for walking
188 MIN 0 - 255 --- Min. stroke adjusted by the potentiometer at machine head.
foot lifting .
Maximum stroke value of potentiometer for walking
189 MAX 0 - 255 --- Max. stroke adjusted by the potentiometer at machine head.
foot lifting .
190 B2 DB2000 speed limiter 200 - 5000 spm 2000 B2 speed limiter setting
191 B3 DB3000 speed limiter 200 - 5000 spm 3000 B3 speed limiter setting
Positioning teaching mode selection.
192 PTE Positioning teaching mode ON/OFF OFF ON:Must be selected when 【176. VDN】 = A,B,C.
OFF:Invalid.
when the power is turned ON or when the first toe down after thread trimming,
Slow inch half stitch function
193 AC2 ON/OFF OFF ON:Enable.
OFF:Disable.
when the pedal is toed down.
Slow inch one stitch function
194 A16 ON/OFF OFF ON:Enable.
OFF:Disable.
Blow air timer
195 T3 0 - 2500 ms 500 Blow air active timer setting
(MH without function)
Edge Sensor Function selection.
Edge Sensor function
196 BF ON/OFF OFF ON:Enable.
OFF:Disable.
foot lifting at Full heeling then up needle only , At trimming after .
Full heeling Up needle only function
197 WDA ON/OFF OFF ON:Enable.
OFF:Disable.
WEDA cutter thread tension delay time
198 WT2 0 - 990 ms 100 WEDA cutter thread tension delay time setting
(MH without function)
WEDA cutter backward running stitches
199 WN2 0 - 5 stitches 1 WEDA cutter backward running stitches setting
(MH without function)
PAGE - 16

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Define the input function of IN4.
DB2:Motor is running by【190. B2】 speed.
IN4=DB2/SPV/NOP/S5/WL  SPV: Speed limited by VHP input. Speed curve controlled by【186. MS】,【187. WS】【188. MIN】【189. MAX】 .
+ 200 IN4 input sw switchover DB2/SPV/NOP/S5/WL DB2
(MH without hardware input) NOP:No function.
S5: Motor is running by medium speed【059. M】.
WL: Wiper output cancel switch.
P INA input logic signal invert
O INA = PSU logical signal invert
W 201 IAV ON/OFF OFF ON:The input logic of each Input signal PSU is reversed.
(MH without function)
E OFF:The input logic of each Input signal PSU is normal.
R
.. INB input logic signal invert
202 IBV INB = PSD logic signal invert ON/OFF OFF ON:The input logic of each Input signal PSD is reversed.
O
OFF:The input logic of each Input signal PSD is normal.
N INE input logic signal invert
203 ICV INE = PSD logic signal invert ON/OFF OFF ON:The input logic of each Input INE signal is reversed.
OFF:The input logic of each Input INE signal is normal.
BL controller interface control function selection.
204 BL BL controller interface control ON/OFF OFF ON:Enable for Pegasus BL controller function . NOTE: Valid only when【156. OD】=KS4.
OFF:Disable.
For the hemming guide device of USA Bottoms Associates Inc.
Mode selection for hemming guide device OFF:Normal sewing mode.
205 BAF OFF,1,2 OFF
(MH without function) 1:For manual mode hemming guide device.
2:For auto mode hemming guide device.
motor starting position adjustment, the scal range (1 ~ 6) valid.
206 N1 motor starting trigger position by pedal 1 - 99 1 N1 = 10 for Slow start running speed curve.
N1 = 11 for Fast start running speed curve.
207 N2 thread cutting trigger position by pedal 1 - 99 5 thread cutting position adjustment, the scal range (1 ~ 6) valid.
PAGE - 17

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
208 VER Software Version - MH-4.07
Define the source of Index point is from needle up signal or needle down signal.
209 IDX Define the source of Index ( reference ) point UP/DN UP UP: The reference index point is from the needle up signal .

DN: The reference index point is from the needle down signal.
210 FK1 Thread Nipper start angle 0 - 359 degrees 0 FK output start angle setting. Valid only when 【155. OB】 = FK .
211 FK2 Thread Nipper end angle 0 - 359 degrees 10 FK output end angle setting. Valid only when 【155. OB】 = FK .
P The timing prior to HP speed
O 212 THP 80 - 500 ms 100 Setting the timing prior to HP speed.
W
(MH without function)
E Setting the number of stitches for HP function of walking foot .
R Setting the number of stitches for HP function
.. 213 CHP 0 - 255 stitches 0 0 : Function disable.
(MH without function)
1 ~ 255 : Enable. Valid only when 【062. HPM】=ALT.
O
Needle cooling output mode selection.
N 0 : Normal needle cooling function.
214 FNK Functions of the output "needle cooling" 0,1,2 0
1 : Needle cooling operates when sewing speed excesses the setting value of 【216. NK】.
2 : Under edge trimmer.
215 T5 Setting the needle cooling delay time 0 - 2550 ms 0 Setting the needle cooling delay time from motor stops
216 NK Setting the needle cooling operating point of speed 40 - 6000 spm 40 Needle cooling will operate when sewing speed excesses this setting value. Valid only when 【214. FNK】=1.
Lift roller output mode selection.
0 :Roller works independently.
1 :Roller works with foot lifter and back tacking.
217 FLK Lift roller function 0,1,2,3,4,5 0 2 :Roller works with foot lifter.
3 :Roller works with back tacking.
4:Roller works with foot lifter and back tacking. (Back tacking delay puller output by [096. WN3] stitch.)
5 :Roller works with back tacking. (Back tacking delay puller output by [096. WN3] stitch.)
Tension release output mode selection.
0 : Tension R. output depends on the timing of 【080. LLM】 only.
218 STR Tension release output function 0,1,2 0
1 : Tension R. operates with foot lifting after motor stop.
2 : Tension R. operates with foot lifting after trimming or power on.
IN5=DB3/NOP/S5B  Define the input function of IN5.
input sw mode switchover DB3:Motor is running by【191. B3】speed.
219 IN5 DB3/NOP/S5B DB3
(MH without NOP:No function.
hardware input) S5B: Motor is running by bar tacking 【006. B】speed.
Define the input function of INB.
NOP:No function.
PSD:Emergency stop for down position.
SPB:Speed limited by end bar tacking 【005. V】 speed.
INB=NOP/PSD/SPB/IO1/DB3/CRS/ST1/ST2/ST3/S2  NOP/PSD/SPB/IO1/ IO1:Must be selected when【047. MAC 】= 15 or 16 or 17 .
220 INB input sw DB3/CRS/ST1/ST2/ S2 DB3:Motor is running by【191. B3】speed.
mode switchover ST3/S2 CRS:An input signal for counter reset .Note : Valid only when 【042. CUD】=U,D,US,DS,UT,DT,UTS,DTS .
ST1:Inching one stitch only.
ST2:Up needle + Tension on + Sewing suppression + BTL Lamp blinks .
ST3:Up needle + Tension on + presser foot + Sewing suppression + BTL Lamp blinks .
S2:Trimming signal .
Define the input function of INJ.
NOP:No function.
BTL:Back-tacking suppression / recall switch for SBT/ EBT only.
INJ=NOP/BTL/HP/U/S1/BTC/ST1/ST2/ST3 HP:The switch for high lift for walking foot.
input sw mode NOP/BTL/HP/U/S1/ U:Needle up function of 【125. USM 】.
221 INJ BTL
switchover BTC/ST1/ST2/ST3 S1:Motor is running by VC, if【143. AT】=ON; then running by【009. A】speed.
(MH without hardware input) BTC:Back-tacking suppression + O5 BTL Lamp On / cancel for SBT/ EBT only..
ST1:Inching one stitch only.
INJ=NOP/BTL/HP/U/S1/BTC/ST1/ST2/ST3 PAGE - 18
input sw mode NOP/BTL/HP/U/S1/
221 INJ BTLMH Parameters List MH-4.07 E1
switchover BTC/ST1/ST2/ST3
(MH without hardware input)
Parameters
Key
Code
Parameters Function Range Pre.setting Description
ST2:Up needle + Tension on + Sewing suppression + BTL Lamp blinks .
ST3:Up needle + Tension on + presser foot + Sewing suppression + BTL Lamp blinks .
PAGE - 19

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description
Trimmer protection function selection when the machine pulley was moved out of the range of 【224.TOA 】.
222 TOF Trimmer protection function ON / OFF ON/OFF OFF ON :【223. S2P】function valid.
+ OFF:【223. S2P】function invalid.
Operation mode selection. Valid only when【222. TOF 】=ON.
Selecting the trimmer protection mode
223 S2P NO/PS NO NO:Operate foot lifting only, without up needle and thread trimming.
when 【222. TOF】= ON
P PS: Operate foot lifting and up needle only, without thread trimming
O
W Setting the range for thread trimmer protection
224 TOA 5 - 40 degrees 10 Setting the range for thread trimmer protection when【222. TOF】= ON
E when【222. TOF】= ON
R
.. motor shake mode select. valid only at 【012. SMS】,【020. SME】setting SU/SD.
Motor shake mode selection
225 CER ON/OFF OFF ON: at each section end of back-tacking.
O
OFF:at reverse on section of back-tacking.
N Stitches prior to the roller is lowered.
226 CTW 0 - 255 stitches 10 Stitches setting.
(MH without function)
ON/OFF switch for 【226. CTW】 ON :【226. CTW】enable.
227 PLC ON/OFF OFF
(MH without function) OFF ︰【226. CTW】disable.
Forward_backward_motion control Function selection.
Forward_backward_motion control function.
228 FBM ON/OFF OFF ON:Enable the function of 【150. INE】= CW, Reverse run will be enabled while the signal ON.
(MH without function)
OFF:Disable.
When 【230. KLC】=ON. Setting the number of stitches for the walking foot operation.
Setting the number of stitches for HP function. 0 : Function disable.
229 KHP 0 - 255 stitches 0
(MH without function) 1 ~ 255 :Stitches setting. Valid only (1). when 【062. HPM】=ALT. 【230. KLC】=ON。
(2). when 【062. HPM】=MON. 【230. KLC】=OFF , 【154. O1 】=KS1 ,【014. SBT】=ON by tape cutter stitches counter.
To operate HP function by half heeling pedal. ON :Enable.
230 KLC (MH ON/OFF OFF
without function) OFF:Disable.
To operate HP function by the knee switch. ON :Enable. When【151. INF】= F
231 FLC ON/OFF OFF
(MH without function) OFF:Disable.
ON: Speed limited by【191. B3】setting.
232 DBA Manual backtack with speed limitation DB3000. ON/OFF OFF
OFF:Function disable.
Knee switch control selection.
233 KNA Knee switch control function. ON/OFF OFF ON:The knee switch can be activated during sewing.( Used for blind stitch machine )
OFF:The knee switch can be activated at sewing stop only.

234 FAR Keep forward or reverse sewing at trimming cycle. ON/OFF OFF ON:Machine keeps forward or reverse sewing at trimming cycle.
OFF:Machine runs forward at trimming cycle.
Setting the number of stitches for the walking foot operation.
0 :Function disable.
Setting the number of stitches for HP function. 1 ~ 255 :Stitches setting. Valid only (1). when 【062. HPM】=ALT. 【153. INK】=HP.【151. INF】=HP.
235 FHP 0 - 255 stitches 0
(MH without function) ( INF must be connected to knee switch )
(2). when 【062. HPM】=MON. 【231. FLC】=OFF , 【154. O1 】=KS1 ,【021. EBT】=ON or 【099. SEN】= ON
by tape cutter stitches counter.
ON : Enable. (Valid only with C300 operation panel selected double start back tacking, C60 invaild)
236 SB1 Single Start back-tacking function ON/OFF OFF
OFF: Disable.
ON: Enable. (Valid only with C300 operation panel selected double end back tacking, C60 invalid)
237 EB1 Single End back-tacking function ON/OFF OFF
OFF:Disable.
CK output ON delay angle
238 CK1 0 - 250 degrees 0 CK output on delay angle setting. Valid only when 【157. O1】or 【158. O3】or 【240. O2】 = CK .
(MH without function)
CK output OFF angle
239 CK2 0 - 250 degrees 10 CK output off angle setting. Valid only when 【157. O1】or 【158. O3】or 【240. O2】 = CK .
(MH without function)
PAGE - 20

MH Parameters List MH-4.07 E1


Parameters
Key
Code
Parameters Function Range Pre.setting Description

O2=NCL/CK  Define the output function of O2.


240 O2 output switchover NCL/CK NCL NCL:Needle cooling output.
(MH without hardware output) CK :Needle down pulse width output .

Stitch length selection after power on ON : Normal stitch length.
241 SLP ON/OFF OFF
(MH without function) OFF: Long stitch length.
P ON : Enable.
O 242 IDC Password Function ON/OFF OFF
W OFF:Disable.
E S10 function selection.
R
..
S10 function ON:Enable. Connected parameter : 【97. TK3 】【144. IN1 】【148. INC 】【152. INI 】【156. OD 】【157. O1 】【158. O3 】【160.
243 S10 ON/OFF OFF
O (MH without function) O5 】【161. O6 】 【 P1=CA 】【P2=CB 】【P3=CC 】【P4=CD 】【P5=CE 】【P6=CF 】【P7=CG 】【244. SFO 】【245. SFC 】

N OFF:Disable.
244 SFO Full-On time setting . 0 - 990 ms 350 For solenoid pulling torque adjustment.
For solenoid's switching power adjustment.
245 SFC Duty cycle time setting . 10 - 90% 40
Foot lifting at motor stop. ON : Enable.
246 SAF ON/OFF OFF
OFF:Disable.
Manual Tape Cutter operation mode . ON : anytime.
247 MTC (Pegasus AT function) ON/OFF OFF
(MH No function) OFF:edge sensor is uncovered.
Delayed timing prior to trimmer engaged
248 T6 0 - 990 ms 0 Valid for【079. LTM】= T4/TK/TS/T7 and [158. O3] = KS4.
(MH without function)
Trimming time
249 T7 0 - 990 ms 0 Valid for【079. LTM】= T1/T3/T4/TK/TS/T7 and [158. O3] = KS4.
(MH without function)
ON : normal footlifting output function
250 FTC Foot lifting output function control. ON/OFF ON
OFF :Trimmer functioned at halfling pedal , disable footlifting output.
Motor driver mode selection.
Motor Driver mode Selection. SK :For Seiko machine serila.
251 MTP SK/DA/PK DA
DA :For standard Version & Durkopp serial.
PK :For Pegasus serial . (MD Not used)